Loading...
HomeMy WebLinkAboutCUPA Report 2015BAKERSFIELD FIRE DEPARTMENT Prevention Services Division Underground Storage Tank Program 2101 H Street DW Inspection Report Bakersfield, CA 93301 Permission to Inspect: �'�� -- ---- Phone: 661 - 326 -3979 Fax: 661 -852 -2171 Business Name: 7- ELEVEN INC #32241 -15- 021 - 019231 Date: 11/19/2015 Address Name: 4101 Calloway Dr- CAL000274247 Inspector Name: Shane Gardner #8248557 Inspection Type: Routine LReport: Final NVO = No Violation Observed OUT = Out of Compliance NA = Not Applicable UD = Undetermined COS = Corrected On Site RPT = Repeat Violation Violation Program Requirement°, o SOC Comments No Oj Q o �o O a z O z M 0 W p> File Review Facility Tank Information 2030021 Facility has a valid Permit Tank 1- 15000- DW -REG to Operate from the Tank 2- 10000- DW -PRM CUPA - 23 CCR 16 2712(i); ® ❑ ❑ ❑ ❑ ❑ None Tank 3- HSC 6.7 25284 Tank 4- 2010010 UST Operating Permit Application for Facility information and Tank information ® ❑ ❑ ❑ ❑ ❑ None submitted /maintained - 23 CCR 16 2711; HSC 6.7 25286(a) 2010001 Current BOE number submitted to the CUPA ® ❑ ❑ ❑ ❑ ❑ None and /or CERS - HSC 6.7 25286(c) 2030011 UST compliance statement and /or Designated Operator ® ❑ ❑ ❑ ❑ None current certification submitted - 23 CCR 16 2715(a), 2715(b) 2030046 A complete and accurate response plan has been submitted, approved and ® ❑ ❑ ❑ ❑ ❑ None maintained - 23 CCR 16 2632, 2634(e), 2641(h), 2712(1 2030041 A complete and accurate plot plan has been submitted, approved and ® ❑ ❑ ❑ ❑ ❑ Minor maintained - 23 CCR 16 2632(4 )(1 C , 2711(a (8 2010006 Owner /Operator has not made false statements or representation on any ® ❑ ❑ ❑ ❑ ❑ None required document - HSC 6.7 25299 2010003 Owner /Operator has a DO and /or informed the CUPA of any change (s) ® ❑ ❑ ❑ ❑ ❑ None within 30 days - 23 CCR 16 2715(a) Violation Program Requirement ° g SOC Comments No a o O a do z O z 0 W p� Testing 2030002 Owner /Operator has tested and certified leak ® ❑ ❑ ❑ ❑ ❑ None detection equipment annual) - 23 CCR 16 2638 2030048 Secondary containment testing conducted every 36 months in accordance ® ❑ ❑ ❑ ❑ ❑ None with requirements - 23 CCR 16 2637 2030055 Spill buckets have been tested annually as ® ❑ ❑ ❑ ❑ ❑ None required - HSC 6.7 25284.2 2010009 Secondary containment test results submitted to the CUPA within 30 days ® ❑ ❑ ❑ ❑ ❑ None after the test - 23 CCR 16 2637(e) 2030064 CUPA was poperly notified within the prescribed number of ® ❑ ❑ ❑ ❑ ❑ None hours prior to testing - 23 CCR 16 26370, 2638(e), 2643(g), 2644.1(a)(4) Install /Repair 2060009 Permits obtained to install, replace, repair, or ® ❑ ❑ ❑ ❑ ❑ None modify part of the UST system - 23 CCR 16 2712 UST System Observation General Monitoring 2030003 Leak detection system maintains continuous RD monitoring that activates ® ❑ ❑ ❑ ❑ ❑ None ❑ an audible and visual Yes alarm - 23 CCR 16 2632, 2634, 2636, 2666 2030016 The annular space of the tank, piping and sumps RD are continuously monitored and activates ® ❑ ❑ ❑ ❑ ❑ None ❑ the alarm - 23 CCR 16 Yes 2631(8), 2632(c)(2)(A) &(8), 2633 c , 2636 2030017 Product piping outside the UDC is fail -safe and shuts down the pump or ® ❑ ❑ ❑ ❑ ❑ None restricts flow - 23 CCR 16 2636(1) (5) 2030018 Turbine sump monitor RD activates an audible and visual alarm or stops the ® ❑ ❑ ❑ ❑ ❑ None ❑ flow of at the dispenser - Yes 23 CCR 16 2636(1)(1) Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement a°, o SOC Comments No p = a o �c 0 a z O z n 0 W 2030019 Monitoring system in the Float and Chain assembly UDCs activates an audible and visual alarm ® ❑ ❑ ❑ ❑ ❑ None or stops the flow at the UDC - 23 CCR 16 2636 (0(1) 2030043 Leak detection equipment properly programmed or RD properly operated - 23 ® ❑ ❑ ❑ ❑ ❑ None ❑ CCR 16 2632, 2634, 2636, Yes 2666 2060005 System constructed with a monitoring system capable of detecting entry ® ❑ ❑ ❑ ❑ ❑ None into secondary containment - HSC 6.7 25291 b) 2060014 Correct leak detection equipment installed for RD the type of system ® ❑ ❑ ❑ ❑ None ❑ present - 23 CCR 16 2638; Yes HSC 6.7 25290.1, 25290.2, 25291 2060015 Sensor located in the RD proper position /location - ® ❑ ❑ ❑ ❑ [] None ❑ 23 CCR 16 2630(d), 2641(a) Yes 2030062 Facility is in compliance with not tampering with or RD disabling leak detection ® ❑ ❑ ❑ ❑ ❑ None ❑ devices or alarms - HSC Yes 6.7 25299 a (9) 2060022 System constructed with a monitoring system capable of detecting entry ® ❑ ❑ ❑ ❑ ❑ None into secondary containment - HSC 6.7 25290.2(d) 2030034 Tag /sticker on affixed monitoring equipment being certified, repaired, ® ❑ ❑ ❑ ❑ ❑ None or replaced - 23 CCR 16 2638(1) VPH Monitoring VPH 2030065 Interstitial monitoring of the annular spaces of the RD UST is properly ❑ ❑ ® ❑ ❑ ❑ None ❑ maintained - HSC 6.7 Yes 25290.1(e) 2060023 System constructed with a monitoring system capable of detecting entry into secondary ❑ ❑ ® ❑ ❑ ❑ None containment - HSC 6.7 25290.1(d) Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement 4- 0 0.0 SOC Comments No 0 > 0 W 0 M 4.0 cc 0 Z 0 Z 05, 0 Line Leak Detector 2060012 Line leak detector installed on pressurized RD piping system - HSC 6.7 0 El ❑ E-1 F-1 ❑ None ❑ 25290. 1 (h), 25290.2(8), Yes 252910, 25292(e), 2636(0(2) 2030026 Line leak detectors detect a 3 gph leak and/or RD audible and visual alarm 0 El ❑ ❑ ❑ ❑ None ❑ function properly - 23 Yes CCR 16 2636(0(6), 2666(c) 2030027 Turbine shuts down when a leak is detected or RD when line leak detector is E-1 ❑ 2 ❑ E-1 ❑ None ❑ disconnected - 23 CCR 16 Yes 2666(c) 2030025 Pressurized piping able to detect a 3.0 gph leak RD within an hour, and E ❑ ❑ ❑ None ❑ restricts the flow or Yes alarms - 23 CCR 16 2636(0(2) Secondary Containment 2060010 UST storing a hazardous RD substance has secondary ❑ ❑ None ❑ containment - HSC 6.7 Yes 25292 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement ° o SOC Comments No O Q o O a �o Z O z M V p> 2030008 UDC, sumps, and /or other secondary containment in good ® ❑ ❑ ❑ ❑ ❑ None condition and /or are free of debris /liquid - HSC 6.7 25290.1, 25290.2, 25291 2030040 Secondarily contained RD piping maintained to allow ® ❑ ❑ ❑ ❑ ❑ None ❑ liquid to drain into sump - Yes 23 CCR 16 2630(d), 2641(a) 2060006 Secondary containment piping slopes back to the ® ❑ ❑ ❑ ❑ ❑ None collection sump - 23 CCR 16 263(c 2030047 Secondary containment maintained tight and has been confirmed by testing ® ❑ ❑ ❑ ❑ [] None - 23 CCR 16 2662; HSC 6.7 25290.1(c)(2), 25290.2(c)(2), 25291(a), 25292(e) 2030060 Entry fittings in secondary containment for UST system maintained ® ❑ ❑ ❑ ❑ ❑ None tight/sealed - 23 CCR 16 2630, 2635(d), 2636(c), 2666 2060020 Spill bucket is installed RP and has a functional drain valve or other means to ® ❑ ❑ ❑ ❑ ❑ None ❑ remove liquid - 23 CCR 16 Yes 2635(b), 2665 2030054 Spill bucket maintained in RP good condition and free of ® ❑ ❑ ❑ ❑ ❑ None ❑ debris and /or liquid - 23 Yes CCR 16 2635(b), 2715(c)(2) 2060019 Spill bucket to has a minimum capacity of five ® ❑ ❑ ❑ ❑ ❑ None gallons - 23 CCR 16 2635(b), 2665 Overfill 2030035 UST system is operated RP to prevent unauthorized release, including spills ® ❑ ❑ ❑ ❑ ❑ None ❑ and overfills - HSC 6.7 Yes 25292.1 a 2030036 Overfill prevention system RP has not been overridden and meets overfill ® ❑ ❑ ❑ ❑ ❑ None ❑ requirements - 23 CCR 16 Yes 2635(b)(2), 2665 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement 0.0 SOC Comments No 4 0 4 a M z O z M V w p> On Site Records Certifications 2030023 Required designated operators or contractors maintain a proper and ® ❑ ❑ ❑ ❑ ❑ None current ICC certification - 23 CCR 16 2715 2030024 Service technician, installer, and/ or employee maintain a ® ❑ ❑ ❑ ❑ ❑ None proper license - 23 CCR 162715 2030031 Employee or contractor obtained and maintained proper manufacturer ® ❑ ❑ ❑ ❑ ❑ None certification - 23 CCR 16 2715 2010007 Submit/maintain current Certificate of Financial Responsibility /mechanism of financial assurance - ® ❑ ❑ ❑ ❑ ❑ None 23 CCR 16 2711; 23 CCR 182808.1 ' 2809 - 2809.2; HSC 6.7 25292.2; HSC 6.75 25299.30- 25299.34 Designated Operator 2010004 Copies of DO inspections for last 12 months and list of trained employees ® ❑ ❑ ❑ ❑ ❑ None maintained - 23 CCR 16 2715 2030013 Designated operator properly conducted the monthly inspection and ® ❑ ❑ ❑ ❑ ❑ None the reports are complete - 23 CCR 16 2715 2030010 DO notified operator of any condition observed during the monthly ® ❑ ❑ ❑ ❑ ❑ None inspection that may require action - 23 CCR 16 2715(q) 2030012 DO employee training performed, current for at least one employee on ❑ ❑ ❑ ❑ ❑ None site, and a log kept - 23 CCR 16 2715(c)(6), 2715(0 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement a°, o SOC Comments No O _ Q c O a arc Z O z U �j Logs 2030001 Leak detection alarm logs, maintenance and RD records of appropriate ® ❑ ❑ ❑ ❑ ❑ None ❑ follow -up actions Yes maintained - 23 CCR 16 2632, 2634, 2712(b) Maintenance/Tests 2010008 Monitoring, maintenance, repairs, linings, and RD upgrade records ® ❑ ❑ ❑ ❑ ❑ None El maintained for the proper Yes time period - 23 CCR 16 2712(b) Documentation 2030033 Failure to maintain on site an approved monitoring ® ❑ ❑ ❑ ❑ ❑ None plan - 23 CCR 16 2632, 2634, 2711, 2712(1) 2.030037 Written agreement between the tank owner and tank operator to monitor the tank system ❑ ❑ ® ❑ ❑ ❑ None is maintained - 23 CCR 16 2620(b); HSC 6.7 25284(a)(3 2030061 Suspected or actual RD unauthorized release reported in appropriate ❑ ❑ ® ❑ ❑ ❑ None ❑ time frame - HSC 6.7 Yes 29294, 29295 General Operating Requirements Permit Condition /Approval 2030039 Compliance with all operating permit ® ❑ ❑ ❑ ❑ ❑ None conditions - 23 CCR 16 2712; HSC 6.7 25299 2030059 UST system maintained in accordance with exclusion /exemption ® ❑ ❑ ❑ ❑ ❑ None status - HSC 6.7 25281.6, 25283.5 2030014 Owner /Operator received approval and has implemented a training ❑ ❑ ® ❑ ❑ ❑ None program at an unstaffed facility - 23 CCR 16 2715( 2) 2030015 Facility exhibited that the method used to monitor the tank meets the monitoring methods in ® ❑ ❑ ❑ ❑ ❑ None 2643(f) - 23 CCR 16 2643 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement 4- 0 0.0 SOC Comments No 0 > 0 0 IL 4" cc 0 z 0 z D 0 W 05 Red Tag 2030045 Red Tag information is legible and has not been None tampered with - 23 CCR 16 2 717. 1 (g) 2030044 Facility did not allow for deposit of petroleum into a UST that has a red tag None affixed to the fill - 23 CCR 162717.1(0 Install/Repair 2060024 UST system is made of or lined with materials that are compatible with the None substance stored - 23 CCR 16 2631.1 2060021 Striker plate installed and positioned correctly - 23 ❑ ❑ ❑ ❑ ❑ None CCR 1_6 2631(c), 2662(d) Z There were no violations noted for this inspection. ❑This report shall serve as a "NOTICE TO COMPLY" for Minor Violations, and a "NOTICE OF VIOLATION" for Major violations. You are, hereby, ordered to correct the above noted violations within 30 days, or according to correction summaries provided. Formal enforcement and/or penalty assessment may be initiated for any violations noted, and for those not corrected in a timely manner. (NOTE: If this is a preliminary report, a final report will follow.) Inspectors Signature: Date: Inspector: Enter # of Violations: RD: RP: Check one box for facility Significant Operational Status (SOC) to be reported to SWRCB and US EPA: r-1 SOC with both Release Detection and Release Detection (Facility has no Release Prevention and no Release Prevention Violations) ❑ Not in SOC (Facility has both Release Prevention and Release Detection Violations) ❑SOC with Release Detection only (Facility has no Release Detection violations but one or more Release Prevention violations) F-1 SOC with Release Prevention only (Facility has no Release Prevention violations but one or more Release Detection violations) Underground Storage Tank Program - DW Inspection Report v 2.0 BAKERSFIELD FIRE DEPT. Prevention Services ».... F...R...: ....... t. f, p UNIFIED PROGRAM INSPECTION CHECKLIST.' FARE 2101 x Street v,.. h.. .........k...:...:k::'.. »...... Bakersfield CA 93301 Haz -Mat. Business Plan and Inventory Program Tel.: (661) 326 -3979 Fax: (661) 852 -2171 FACILITY NAME INSPECTION DATE INSPECTION' TIME ADDRESS PHONE NO. NO OF EMPLOYEES FACILITY CONTACT BUSINESS ID NUMBER Consent to Inspect NaTrie /Title. 0 Correct the violation(s) noted above by Signature (that all violations have been corrected as noted) • Within 5 days of correcting all of the violations, sign and return a copy of this page to: Bakersfield Fire Dept., Prevention Services, 2101 H Street, California 93.501 Date White —Business Copy Yellow - Business Copy to be Sent in after return to Compliance Pink Prevention Services Copy. FD2155 (Rev 1/14) ❑ ROUTINE ° COMBINED ❑ JOINT AGENCY ❑ MULTI - AGENCY ❑ COMPLAINT ❑ RE- INSPECTION C V ( C= Compliance OPERATION:,. V= Violation . COMMENTS ❑ VISIBLE ADDRESS (CFC :505.1, BMC:151.52.020) El APPROPRIATE PERMIT ON HAND (BMC: 15.65.080) ❑ CERS UPDATED FOR THE CURRENT CALENDAR YEAR (H &S 25404(e) ❑ BUSINESS PLAN CONTACT INFORMATION ACCURATE (CCR: 2729.1) ' ❑ VERIFICATION OF_ INVENTORY MATERIALS (CCR: 2729.3) . ❑ VERIFICATION OF QUANTITIES (CCR: 2729.4) ❑ VERIFICATION OF LOCATION (CCR: 2729.2) El SEGREGATION OF MATERIAL (CFC: 5004.1) ❑ SAFETY DATA SHEET AVAILABILITY (CCR: 2729.2(3)(b)) ❑ VERIFICATION OF HAZ MAT TRAINING (CCR: 2732) ❑ VERIFICATION OF ABATEMENT SUPPLIES AND PROCEDURES (CCR:2731(c)) ❑ EMERGENCY PROCEDURES ADEQUATE (CCR: 2731 ) ❑ CONTAINERS PROPERLY LABELED (CCR: 66262.34 (f); CFC: 5003.5) ❑ HOUSEKEEPING (CFC: 304.1) f ' ❑ FIRE PROTECTION (CFC: 903 & 906) ❑ SITE DIAGRAM ADEQUATE & ON HAND (CCR: 2729.2 (3)) ANY HAZARDOUS WASTE ON .SITE? )I YES ❑ NO Explain.: mil,,. i nature of Receipt: POST INSPECTION INSTRUCTIONS FOR RETURN -TO- COMPLIANCE: 0 Correct the violation(s) noted above by Signature (that all violations have been corrected as noted) • Within 5 days of correcting all of the violations, sign and return a copy of this page to: Bakersfield Fire Dept., Prevention Services, 2101 H Street, California 93.501 Date White —Business Copy Yellow - Business Copy to be Sent in after return to Compliance Pink Prevention Services Copy. FD2155 (Rev 1/14) HAZARDOUS WASTE``?,. BAKERSFIELD FIRE DEPARTMENT UNIFIED PROGRAM CONSOLIDATED FORMS Prevention Services ' 8:... _R....s..... .:'... D 2101 H Street FIRE SMALL QUANTITY HAZARDOUS . �� AR N r Bakersfield, CA 93301 WASTE GENERATOR INSPECTION Phone: 661- 326 -39.79 •Fax: 661 =852 -2171 Facility Name: .. }l Date: Site Address:.`' r �- % '`' d Time In: Time Out: / Owner /Operator:. +` f Phone: EPA ID e . Type of Inspection ;Coutine 0 :Re- inspection/Foll ow -up 0 Combined Routine Inspec�r�" fl °Joint Inspection 0 Complaint 0, Focused . 0 Other ONSENT TO INSPECT GRANTED BY (Name / Title)"'` Inspection may involve obtaining photographs, review and copying of records, .and determination of compliance with hazardous waste handling requirements. l'\ -I--- _ T.T /'77.....T TT.:._ A X­ XT: C V I HAZARDOUS WASTE REQUIREMENT N/A CERS Violation # COMMENTS Recordkee in documentation Generator has an EPA ID number [HSC 25143.13] 3010002 { Hazardous` waste determination made for all wastes 0 Analysis-�'9;iaenerator. Knowledge' [CCR 66262.40] 3030005. Contingency plan information poste d near phone [CCR 66262.34(d)(2)] 3010022 . , Facility oersomiel. demonstrate training /awareness [CCR 66262.34(d)(2)] 3020001 Manifests /Consolidated Manifest receipts complete [CCR 66262.23(a)] 3010008 Blue copy(s) of manifest mailed to DTSC [CCR 66262.23(a)(4)] 3010011 -Bills of Lading/receipts available [CCR 66262.40(a)] 1 3010010 . LDRs available and complete [CCR 66268.7(a)] } 3030006 Onsite recycling ooed using UPCF [HSC 25143.10] t 3030001 Container /tank management Containers are in. ood condition [CCR 66262.34(d)(2)] 3030013 Containers are closed, except when adding/removing [CCR6626234(d)(2)] 3030017 Satellite containers at or near point of generation [CCR 66262.34(e)(1)(A)] Empty containers are empty [CCR 66262..34(f)], 3030007 Containers inspected weekly [CCR 66262.34(4)(2)] 3030019 Tanks inspected daily [CCR 66262.34(4)(2), 40CFR 265.2011 # 3030027 One container per waste stream at satellite area [CCR 66262.34(4)(2)] ± 3030022 Exclude recyclable materials stored in accordance with local ordinance%hazardous materials, codes [HSC 25143:10] ' .3010016 Accumulation Time Limits Waste is accumulated not more than 90/ 70 . [CCR 66262.34(d)] 3030010 Empty containers 'managed within one year [CCR 66262.34(d)] 3030010 Universal waste accumulated less than one year [CCR 66273.15(a)] 3030011 Used oil filters offsite within 180 (1 year <1 ton) [CCR. 66266.130(c)(4)] 3030004 . Pb -acid batteries offsite within 180 (1 yr. < 1 ton) [CCR66266.81(a)(3)] 3030002 Labeling/Marking Containers are properly labeled [66262.34(f)] 3030007 Excluded recyclable materials marked properly [HSC 25143.9(a)] 3050005 Universal waste container properly labeled (CCR 66273.34] 3030008 Used oil filters marked "drained, used oil filters" [CCR 66266.130] 3030004 Date written on spent lead -acid batteries [CCR 66266.81(a)(6)(B)] 3030003 "Used Oil" marked on all used.oil tanks /containers. [CCR 66279.21(b)] 3030007 >47-> Tank marked with "haz waste" , contents, start date [66262.34(f)] 3030007 Treatment, Transport and Disposal/Other Have permit/authorization to do treatment [HSC 25136.21 1 3040003 Waste sent with authorized transport (gen. eligible) [CCR 66263.41] 1. 3050001 Waste disposed of to authorized point/party [HSC 25189.5(a)] 3050002. Failed to properly handle appliance wastes [HSC 25212(a)] Fire Protection [66262.34(d)(2)] a. 3030032. Print and sign in this box for receipt of this report. Signature does not imply agreement with findings only receipt of report. INSPECTOR ^ " / -?IA POST INSPECTION INSTRUCTIONS: • Correct the violation(s) noted above by • Within 5 days of correcting all of the violations, sign and return a copy of this page to: Bakersfield Fire Dept:, Prevention Services; 2101 H St. Bakersfield, CA 93301 Signature (that all violations have been corrected as noted) Date FD2171 (Rev 9/14) White - Business Copy Yellow- Station Copy Pink - Prevention Services Copy