Loading...
HomeMy WebLinkAboutAPSA RTC 4/22/2016I UNIFIED PROGRAM INSPECTION CHECKLIST Aboveground Petroleum Storage Tank Program FACILITY NAME @q #p INSPECTION DATE INSPECTION TIME ADDRESS Prepare an SPCC plan [CFR 112.3] PHONE NO. NO OF EMPLOYEES FACILITY CONTACT BUSINESS ID NUMBER CONSENT TO INSPECT NAME /TITLE DESCRIPTION Y N N/A ENTS Prepare an SPCC plan [CFR 112.3] Review or amend SPCC plan [CFR 112.5 (a)(d)] SPCC plan available on site [CFR 112.3(e)] f _ >: Conduct inspections and test in accordance with written procedures [CFR 112.7(e)] Maintain records of inspections, tests and/or procedures [CFR 112.7(e)] Records of inspections or tests signed by inspector [CFR 112.7(e)] N. DESCRIPTION YJ N N/A COMMENTS Self - certification for Tier I or H facility [112.6(a)(1),(b)(1) Professional engineer certification [CFR 112.3(d) and 11 2.6(b)(4)] Documentation of 5 year review and evaluation of SPCC plan [CFR 112.5(b)] Amendments required within 6 months of changes/certifications [CFR 112.5(a) and 112.6(a)(2), (b)(4) Management authorization of resource commitment to implement the SPCC [CFR 112.7 & 112.6(a) Diagram with location and contents of containers, transfer stations, connecting piping [112.7(a)(3)] Type of oil and storage capacity for each container [CFR 112.7(a)(3)] Discharge prevention measures and procedures for routine handling {CFR 112.7(a)(3)] Countermeasures for discovery, response and clean-up [CFR112.7(a)(3)] Required contact list and phone numbers [CFR 112.7(a)(3)] DESCRIPTION Y N N/A COMMENTS Provide corrosion protection [CFR I12.8(c)(4)(5), (d)(1)] Containers compatible with materials stored [CFR 112.8(c)(1) Implement SPCC plan review changes or amendments within 6 months [CFR 112.5(a)(d)] Prepare an oil contingency plan or written control /removal commitments [CFR 112.7(d)] CCf Tlll1U A- %'Uh(- vL7n I rnini , r -is utnrnla man irn 16 1S1TpTu t.nnp_" DESCRIPTION Y N N/A COMMENTS Training program [CFR 112.7(f)] Train personnel in operation and maintenance of equipment [CFR 112.7(f)] Conduct annuals ill prevention briefings [CFR 112.7(f)(3)] CG!'TIll1U c.• r- nntnrni7 manurn 7G tiATC.TU I:nr10' /h //11 LL 2-1 DESCRIPTION YJ N N/A COMMENTS Meet provisions of conditional exemption [H &S 25270.4.5(b) Facility security adequate [CFR 112.7(g)] Clean-up materials readily available CFR 1 12.7 c Overfill protection procedures or devices in place and operative [CFR 112.8(c)(8)] Portable /mobile containers positioned to prevent discharge [CFR 1 12.8(c)(11) Loading / unloading rack drains into containment area [CFR 112.7(h)] Provide appropriate containment /diversionary structures to prevent discharge CFR 112.8(a), 112.7(c)] Secondary containment adequate to contain capacity of largest container + precipitation [CFR 112.8(c)] Remove accumulation of oil in secondary containment [CFR 112.8(c)(10)) Secondary containment valve(s) closed CFR 112.8] Implement SPCC plan elements [CFR 112.3] NY HAZARDOUS WASTE ON SITE? ?'a YES ❑ NO Si nature ofReceipt xplain: POST INSPECTION INSTRUCTIONS: • Refer to the back of this inspection report for regulatory citations and corrective actions • Correct the violation(s) noted above by 17, . fl, • Within 5 days of correcting all of the violations, sign and return a copy of this page to: Bakersfield Fire Dept., Prevention Services, 2101 H Street, California 93301 Date Pink - Prevention Services Copy White - Business Copy Yellow - Business Copy to be Sent in after return to Compliance Signature -(that all violations have been corrected as noted) FD2156b (Rev 9/10)