HomeMy WebLinkAboutFire Safety Insp 5-17-16- _ . ............. . . .. - - -------- .......
cy
BAKERSFIELD FIRE DEPARTMENT
FIRE PREVENTION INSPECTION B E R S F I D Prevention services
z {j 2101 H Street
FIRE
aRrm Bakersfield GA 93301
..t
W ' Phone: 661 -326 -3979 - Fax: 661- 852 -2171
DISTRICT
BLOCK NO.
DATE /�
i ✓"
FEE'S
F
FACILITY ADD ESS . _
�y
�* ��! iVLtVi�
CITY STAT ZIP
E,
10
FACILITY NAME
MANAGER'S AME
PH NO. ` ¢
BUSINESS OWNER'S NAME AND ADDRESS
CITY, STATE, ZIP ,
PH NO.
BILL TO: (IF DIFFERENT FROM ABOVE) NAME, ADDRESS
CITY, STATE, ZIP
PH .NO.
OCC TYPE
OCC LOAD
NO. OF FLOORS
HIGH RISE BLDG
YES
RISER DATE
P(NO
- CORRECT ALL VIOLATIONS VIOLATION
REQUIREMENTS
CHECKED BELOW No.
Remove and safely dispose
of all hazardous refuse and dry vegetation on the above premises
COMBUSTIBLE WASTE/ DRY
«N "yi
(CFC 304.1:1)
VEGETATION.
2
Provide non combustible
containers with tight fitting lids for the storage of combustible waste and
-
rubbish pending its safe
disposal. (CFC 304.3.2) Note: applies to containers over 40 gallons.
Relocate combustible storage
to provide at least 3 feet clearance around motor fuse box /fire door
coMBUST113LE STORAGE
3
(CFC 605.3)
4
Relocate fire extinguisher(s)
so that they will be in a conspicuous location, hanging on brackets with the
top to the extinguisher not
more than 5 feet above the floor. (CFC 906.5 &906.9)
EXTINGUISHERS
5
Provide and install (amount)
. approved (type & size) portable fire
extinguisher to be immediately
accessible for use in (area)
(CFC TABLE 906.3(1))
s
Re- charge all fire extinguishers.
Fire extinguishers shall be serviced at least once each year, and /or
after each use, by a person
having a valid license or certificate. (CFC 906.2)
7
Provide and maintain "E)67
sign(s) with letters 6 or more inches in height over each required exit
SIGNS'
(door /Window) to fire escape..
(CFC 101.1) 5.
8
Provide and maintain appropriate
numbers on a contrasting background and visible from the street to
" indicate the correct address
of the building. {CFC 505.1) ??;?,i"
9
Repair all (cracks /holes /openings)
in plaster in (location) ;.
SIRE DOORS
Plastering shall return the
surface to its original fire resistive condition. (CFC 703.1)
FIRE SEPARATIONS
10
Remove /repair (item & location)
Self - closing doors shall
be designed to close by gravity, or by the action of mechanical device,.or by an
approved .smoke and heat
sensitive device. Self- closing doors shall have no attachments capable of
preventing the. operation
of the closing device. (CFC 703.2)
11
Remove all obstruction fri
m hallways. Maintain all means of egress free of any storage. (CFC 102873)
EXITS
12
Provide a contrasting colored
and permanently, installed electric light over or near required exit
.
(location)
to clearly indicate it as an exit.. (CFC 1006.3)
STORAGE
13
Remove all storage and /or
other obstructions from fire escape landings and stairways stair shafts. (Fire
escapes /stair shafts are
to be maintained free from obstructions at all times.) (CFC 1003.6) .
14
Extension cords shall not
be used in lieu of permanent approved wiring. Install additional approved
ELECTRICAL APPLIANCES
electrical outlets where needed.
(CFC 605.5)
15
Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet)
(CFC 605.4)
ouTQOOR BURNING
16
Recreational fires or open burning. (CFC 307.1)
FIREWORKS
17
Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.).
OTHER
'g'Z 4 t C_ ! V, i L
a `y 4 + z'=, r.ard -C_.
a
¢?: l h ,a L, . f r :,+�y - fi 6ex cr {: 7 ✓��? li:: ft er`"�rA' 1��,7 .
i
CORRECTION DATE
1
correct the violations noted above by: l,, { f._,_a°..:P
f
.e
LEGEND:
C.F.C. CALIFORNIA FIRE CODE
,t�
CUSTOMER: DFa •^ti -- i `'f'��' 1 �
C.B.C. CALIFORNIA BUILDING CODE
(Signaure) (Please Print Name Legibly, Title)
t r
B.M.C. BAKERSFIELD MUNICIPAL CODE
Nf.PA. NATIONAL FIRE PROTECTION
N
INSPECTOR:�i. +`�- ~^^^ NO.:
ASSOCIATION
N.E.C. NATIONAL ELECTRIC CODE