HomeMy WebLinkAboutCUPA Report 2016C
V
BAKERSFIELD FIRE DEPARTMENT
HAZARDOUS WASTE
COMMENTS
UNIFIED PROGRAM CONSOLIDATED FORMS
B R.._5.. F f
Prevention Services
Generator has an EPA ID number [HSC 25143.131
. _E. ......_D
A
2101 H Street
SMALL'QU.ANTITY HAZARDOUS
t T
Bakersfield, CA 93301
WASTE GENERATOR INSPECTION
Phone: 661 - 326 -3979 •Fax: 661- 852 -2171
Contingency plan information posted near phone [CCR 66262.34(4)(2)]
3010022
Facility Name: `; r "C" /F �Z -rF,.E /4.1 "Di , t C
Facility personnel demonstrate training /awareness . [CCR 66262,:34(d)(2)]
Date: 3-1 -7
Site Address: "� � �; � ; �= � °�
Time In: it ' Time Out: � Z
Owner /Operator: (.0'/ ,L a 1 € f
Phone:
EPA ID # .
: TyDe of Inspection
Blue copy(s) .of manifest mailed to DTSC [CCR 66262.23(x)(4)]
0 0 0
0 Routine 0 Re- inspection/Follow -up Combined Routine
Inspection
0 Joint Inspection
Complaint Focused Other
0 CONSENT TO INSPECT GRANTED BY (Name / Title):
11 r
3010010
Inspection may involve obtaining photographs, review and copying of records; and determination of compliance with hazardous waste handling requirements.
C = Complaint: V = Class 1, Il or Minor Violation
LDRs available and complete [CCR 66268.7(a)]
3030006
C
V
I HAZARDOUS WASTE REQUIREMENT
NIA
CERS
Violation #
COMMENTS
Recordkee in documentation
,
Generator has an EPA ID number [HSC 25143.131
3010002
Hazardous waste determination made for all wastes
0 Analysis ,Generator Knowledge [CCR 66262.401
3030005
Contingency plan information posted near phone [CCR 66262.34(4)(2)]
3010022
Facility personnel demonstrate training /awareness . [CCR 66262,:34(d)(2)]
3020001
Manifests /Consolidated Manifest receipts complete [CCR 66262.23(a)]
3010008
' A V r , - rn < -7-
Blue copy(s) .of manifest mailed to DTSC [CCR 66262.23(x)(4)]
30.10011
Bills of Lading/receipts available [CCR 66262.40(a)]
_
3010010
LDRs available and complete [CCR 66268.7(a)]
3030006
Onsite recycling reported using UPCF [HSC 25143.10]
3030001
Container /tank management
`Containers are in good, condition [CCR.66262.34(d)(2)]
3030013
Containers are closed except when adding/removing [CCR66262.34(d)(2)]
3030017
Satellite containers at or near point of generation [CCR 66262.34(e)(1)(A)]
Em ty containers are empty [CCR 66262.34(f)]
3030007
-
Containers inspected weekly [CCR 66262.34(4)(2)]
3030019
r 7'
Tanks inspected daily [CCR 66262.34(d)(2), 40CFR 265.201]
1
3030027
One container perwaste stream at satellite area [CCR 66262.34(d)(2)]
3030022
Exclude recyclable materials stored in accordance with local
ordinance/hazardous materials codes [HSC 25143.10]
3010016
Accumulation Time Limits
Waste.is accumulated not more than 90/180/270 [CCR 66262.34(d)]
3030010
EmDtv containers managed.withiri one year [CCR 66262.34(d)]
3030010
Universal waste accumulated less than one year [CCR 66273.15(a)]
3030011
Used oil filters offsite within 180 (1 year <1 ton) [CCR 66266.130(c)(451
7
3030004
Pb -acid batteries offsite within 180 (1 yr. < 1 ton) [CCR66266.81(a)(3)]
]
3030002
Labeling/Marking
Containers are properly labeled [66262.34(f)]
3030007
Excluded recyclable materials marked properly [HSC 25143.9(4)]
3050005
Universal waste container properly labeled (CCR 66273.341
3030008
Used oil filters marked "drained used oil filters" [CCR 66266.130]
3030004
Date. written on spent lead -acid batteries [CCR 66266.81(a)(6)(B)l
3030003
"Used Oil" marked on all used oil tanks /containers [CCR 66279.21(b)]
3030007
-'
Tank marked with " haz .waste ". , contents, start date [66262.34(f)]
3030007
Treatment, Transport and Disposal/Other
Have permit/authorization to do treatment [HSC 25136.2]
1
3040003
Waste sent with authorized transport. (gen. eligible) [CCR 66263.41]
3050001
Waste disposed of to authorized point/ party [HSC 25189.5(a)]
3050002
Failed to.properly handle appliance wastes [HSC 25212(a)]
Fire Protection [66262.34(d)(2)]
3030032
Print and,sign_in this box for receipt of this report. Signature does not imply agreement with findings only receipt of report.
INSPECTOR
POST INSPECTION INSTRUCTIONS:
• Correct the violation(s) noted above by
• Within 5 days of correcting all of the violations,, sign and return a copy of this page to:
Bakersfield Fire Dept., Prevention Services, 2101 H St. Bakersfield, CA 93301
White — Business Copy Yellow— Station Copy
Signature (that all violations have been., corrected as noted)
Date
Pink- Prevention Services Copy
FD2171 (Rev 9/14).
BAKERSFIELD FIRE DEPT.
aA
Prevention Services
UNIFIED PROGRAM INSPECTION CHECKLIST FIRE 2101 H street
�.
> �.;.,:..:,..,::..: h.. v....:. r. F .......... .....:..::::..::;::,.:.:;::...v ....:... ..,:....:...w.;,.:. :.,....... ..... .Y..:. v:.::.>:.:.:..»; �.<:.... n.:::.:,. .,....,...;<;;..::..::�:,.:�:<. Bakersfield, CA 93301.
Haz -Mat Business Plan and Inventory Program Tel:: (661) 326 -3979
Fax: (661) 8522171
FICI rt .;a ..:.........................::; ...:::::.::...................
xx
❑ ROUTINE M COMBINED . ❑ JOINT AGENCY ❑ MULTI- AGENCY ❑ COMPLAINT ❑ RE- INSPECTION
C
FACILITY NAME
INSPEC'TIION /.DjATE
INSPECTION TIME
COMMENTS
❑
VISIBLE ADDRESS (CFC: 505.1, BMC :15.52.020)
ADDRESS
PHONE NO.
NO OF EMPLOYEES
(BMC`. 15.65.080)
U a
❑
CERS UPDATED FOR THE CURRENT CALENDAR YEAR
FACILITY CONTACT
BUSINESS ID NUMBER
❑
�0713(1
(CCR: 2729.1)
Consent to Inspect Name /Title
'
❑
FICI rt .;a ..:.........................::; ...:::::.::...................
xx
❑ ROUTINE M COMBINED . ❑ JOINT AGENCY ❑ MULTI- AGENCY ❑ COMPLAINT ❑ RE- INSPECTION
C
V
C= Compliance) OPERATION
V= Violation
COMMENTS
❑
VISIBLE ADDRESS (CFC: 505.1, BMC :15.52.020)
]�
❑
APPROPRIATE PERMIT ON HAND
(BMC`. 15.65.080)
❑
CERS UPDATED FOR THE CURRENT CALENDAR YEAR
(H &S 25404(e)
❑
BUSINESS PLAN CONTACT INFORMATION ACCURATE
(CCR: 2729.1)
'
❑
VERIFICATION OF INVENTORY MATERIALS
(CCR: 2729-3)
6
❑
VERIFICATION OF QUANTITIES
(CCR; 2729.4)
❑
VERIFICATION OF LOCATION
(CCR: 27292)
15b
❑
PROPER SEGREGATION OF MATERIAL
(CFC: 5004.1)
❑
SAFETY DATA SHEET AVAILABILITY
(CCR: 2729.2(3)(b))
❑
VERIFICATION OF HAZ MAT TRAINING
(CCR: 2732)
'
❑
VERIFICATION OF ABATEMENT SUPPLIES AND PROCEDURES (CCR:2731(c))
-ERP
❑.
EMERGENCY PROCEDURES ADEQUATE
(CCR: 2731)
❑
CONTAINERS PROPERLY LABELED (CCR: 66262.34 (f); CFC: 5003.5)
bP
❑
HOUSEKEEPING
(CFC: 304.1)
❑
EIRE PROTECTION .
(CFC: 903 & 906)
❑
SITE DIAGRAM ADEQUATE & ON HAND
(CCR: 2729.2 (3))
ANY HAZARDOUS WASTE ON SITE? EkYES ❑.
NO
Explain :
Si nature of Receipt:
POST INSPECTION INSTRUCTIONS FOR RETURN -TO- COMPLIANCE:
• Correct the violation(s) noted above by Signature (that. all violations have been corrected as noted)
• Within 5 days of correcting all of.the violations, sign and return a copy of this page to:
Bakersfield Fire Dept., Prevention Services, 2101 H Street, California 93301
Date
White Business Copy Yellow - Business Copy to be Sent in after return to Compliance Pink Prevention Services Copy FD2155 (Rev 1/14)
Bakersfield Fire Department Prevention ' tl
2101HSt B SRSF1 D
Bakersfield CA. 93301 FIRE - *�ARTM T
661 - 326 -3911 � ,�� �—
Underground Storage Tank Program
SW Inspection Report
NOTICE TO COMPLY/NOTICE OF VIOLATION
Business Name: WESTCHESTER MOBIL- WILFRED KOMISH
Date:03 /17/2016
Address Name: 3200 F St.- 15- 021 - 071311- CAL000306977
Inspector Name: Shane Gardner #8248557
Inspection Type: Routine
Report: Final
NVO = No Violation Observed OUT = Out of Compliance NA = Not Applicable UD = Undetermined
COS = Corrected On Site RPT = Repeat Violation
elation
Program Requirement
°� o
SOC
Comments
No
Q
o
O
a
m�
010
z
O
z
n
v
W
File Review
cility Tank Information
3;0021
Facility has a valid Permit to
Tank 1- 10000- reg -sw
Operate from the CUPA - 23
❑
❑
❑
❑
❑
None
Tank 2- 10000- PRM -SW
CCR 16 2712(1); HSC 6.7
Tank 3-
25284
Tank 4-
10010
UST Operating Permit
Missing tank info in cers
Application for Facility
information and Tank
information
❑
❑
❑
❑
❑
None
submitted/maintained - 23
CCR 16 2711; HSC 6.7
25286(a) -
10001
Current BOE number
submitted to the CUPA
❑
❑
❑
❑
❑
None
and/or CERS - HSC 6.7
25286(c)
3:0011
UST compliance statement
and/or Designated Operator
current certification
[
❑
❑
❑
❑
❑
None
submitted - 23 CCR 16
2715(a), 2715(b)
10046
A complete and accurate
response plan has been
submitted, approved and
❑
❑
❑
❑
❑
None
maintained - 23 CCR 16
2632, 2634(e), 2641(h),
2712(i)
10041
A complete and accurate
plot plan has been
submitted, approved and
❑
❑
❑
❑
❑
None
maintained - 23 CCR 16
2632(d)(1)(C), 2711(a)(8)
10006
Owner /Operator has not
made false statements or
representation on any
❑
❑
❑
❑
❑
None
required document - HSC
6.7 25299
10003
Owner /Operator has a DO
and/or informed the CUPA
❑
❑
❑
❑
❑
None
of any change (s) within 30
days - 23 CCR 16 2715(a)
sting
Bakersfield Fire Department Prevention
2101 H St
Bakersfield CA. 93301
661- 326 -3911
r a =�
Underground Storage Tank Program
SW Inspection Report
NOTICE TO COMPLY/NOTICE OF VIOLATION
olation
Program Requirement
o SOC
Comments
No
0
0
W '''
d
Z
Z
M
30002
Owner /Operator has
tested and certified leak
❑
❑
❑
❑
❑
None
detection equipment
annual) - 23 CCR 16 2638
30048
Secondary containment
testing conducted every
36 months in accordance
Qa
❑
❑
❑
❑
❑
None
with requirements - 23
CCR 16 2637
30055
Spill buckets have been
tested annually as
❑
❑
❑
❑
❑
None
required - HSC 6.7 25284.2
10009
Secondary containment
test results submitted to
the CUPA within 30 days
❑
❑
❑
❑
❑
None
after the test - 23 CCR 16
2637(e
30042
0.1 gph annual line test
performed and passed for
RD
pressurized piping without
❑
❑
[
❑
❑
❑
None
❑
fail safe or shut down - 23
Yes
CCR 16 2636( (4
30050
0.1 gallon per hour piping
integrity test conducted
RD
every three years (pre-
❑
❑
E0
❑
❑
❑
None
❑
January 1984) - 23 CCR
Yes
16 2643(d)
30051
Piping integrity test or
overfill integrity test
conducted every two
❑
❑
❑
❑
❑
None
years (pre- January 1,
1984 ) - 23 CCR 16 2643(e)
30029
Lined or repaired steel
tank was inspected within
RP
10 years of lining and
❑
❑
❑
❑
❑
None
❑
every 5 years after - 23
Yes
CCR 16 2663
30028
Tank lining certification
submitted to the CUPA
within 30 days, proper
❑
❑
❑
❑
❑
None
tests and inspector used -
23 CCR 16 2663
30067
ELD testing conducted
every 36 months on USTs
located within 1,000 feet
❑
❑
❑
❑
❑
None
of a public drinking well -
23 CCR 16 2644.1(a )(3
10005
ELD testing results sent
to the board and the
CUPA within 60 days of
❑
❑
El
❑
❑
❑
None
completion of the test - 23
CCR 16 2644.1(a)(5)
30056
SIR Report submitted
annually to the CUPA - 23
❑
❑
Ci
❑
❑
❑
None
CCR 16 2646.16)
Bakersfield Fire Department Prevention
2101 H St
Bakersfield CA. 93301
661 - 326 -3911
P
Underground Storage Tank Program
SW Inspection Report
NOTICE TO COMPLY/NOTICE OF VIOLATION
elation
Program Requirement
° o
SOC
Comments
No
o
�•°
z
O
z
M
0
W
o>
30064
CUPA was properly
notified within the
prescribed number of
®
❑
❑
❑
❑
❑
None
hours prior to testing - 23
CCR 16 26370, 2638(e),
2643(g), 2644.1(a)(4)
Install /Repair
30009
Permits obtained to
install, replace, repair, or
❑
❑
❑
❑
❑
None
modify part of the UST
system - 23 CCR 16 2712
UST System Observation
,neral Monitoring
30003
Leak detection system
maintains continuous
RD
monitoring that activates
[�,l
❑
❑
❑
❑
❑
None
❑
an audible and visual
Yes
alarm - 23 CCR 16 2632,
2634, 2636, 2666
30017
Product piping outside the
UDC is fail -safe and shuts
down the pump or
91
❑
❑
❑
❑
❑
None
restricts flow - 23 CCR 16
2636(1) (5)
30018
Turbine sump monitor
activates an audible and
RD
visual alarm or stops the
❑
❑
[9
❑
❑
❑
None
❑
flow of at the dispenser -
Yes
23 CCR 16 26360(1)
30019
Monitoring system in the
UDCs activates an
audible and visual alarm
❑
❑
❑
❑
❑
None
or stops the flow at the
UDC - 23 CCR 16
2636 (0(1)
30043
Leak detection equipment
properly programmed or
RD
properly operated - 23
®
❑
❑
❑
❑
❑
None
❑
CCR 16 2632, 2634, 2636,
Yes
2666
30005
System constructed with
a monitoring system
capable of detecting entry
❑
❑
❑
❑
❑
None
into secondary
containment - HSC 6.7
25291(b)
30014
Correct leak detection
equipment installed for
RD
the type of system
❑
❑
❑
❑
❑
None
❑
present - 23 CCR 16 2638;
Yes
HSC 6.7 25290.1, 25290.2,
25291
50015
Sensor located in the
RD
proper position /location -
❑
El
El
El
F-1
None
❑
23 CCR 16 2630(d), 2641(a)
Yes
Bakersfield Fire Department Prevention
2101 H St
Bakersfield CA. 93301
661 - 326 -3911
Underground Storage Tank Program
SW Inspection Report
NOTICE TO COMPLY/NOTICE OF VIOLATION
ola #ion
Program Requirement
o
SOC
Comments
No
�•
Z
o
°-
z
v
o>
30062
Facility is in compliance
with not tampering with or
RD
disabling leak detection
El
❑
❑
❑
❑
❑
None
❑
devices or alarms - HSC
Yes
6.7 25299 a (9
30034
Tag /sticker on affixed
monitoring equipment
being certified, repaired,
❑
❑
❑
❑
❑
None
or replaced - 23 CCR 16
2638(
thodic Protection
30009
Impressed- current system
is turned on and
RP
functioning properly and
�d
❑
❑
❑
❑
❑
None
❑
inspected as required - 23
Yes
CCR 16 2635 a 2
igle Walled
Tank Monitoring
30004
Automatic tank gauge
tests the tank at least
RD
once per month at 0.1
❑
❑J
❑
❑
❑
None
❑
gallons per hour - 23 CCR
Yes
16 2643(b)(2)
30005
The 0.2 gallons per hour
continuous in tank leak
RD
detection test is being
LP
❑
El
❑
❑
❑
None
❑
conducted - 23 CCR 16
Yes
2643 b 5
30006
Monthly 0.2 gallons per
hour automatic tank
RD
gauging test on a single
�
El
1:1
1:1
❑
F-1
None
❑
wall tank is being
Yes
conducted - 23 CCR 16
2643(b)(1)
30002
Automatic tank
gauging /continuous in
RD
tank leak detection
❑
❑
ff]
❑
❑
❑
None
❑
system installed /properly
Yes
functioning - 23 CCR 16
2643, HSC 6.7 25292(a)
30030
Weekly manual tank
gauging performed in
RD
accordance to the
❑
❑
f�lj
❑
❑
❑
None
❑
required specifications -
Yes
23 CCR 16 2645
30022
Groundwater and /or
vadose zone monitoring
❑
❑
❑
F I
R
None
conducted as required -
23 CCR 16 2647, 2648
igle Walled
Piping Monitoring
30052
Piping monitored hourly
and a 0.2 gph monthly or
RD
0.1 gph annual line
❑
❑
❑
❑
❑
None
❑
integrity test is performed
Yes
- 23 CCR 16 2641(a),
2643(c)
to Leak
Detector
Bakersfield Fire Department Prevention
2101 H St
Bakersfield CA. 93301
661 -326 -3911
z
Underground Storage Tank Program
SW Inspection Report
NOTICE TO COMPLY/NOTICE OF VIOLATION
olation
Program Requirement
o
SOC
Comments
No
O
m .�
Z
O
Z
U
m
Gy
30012
Line leak detector
installed on pressurized
RD
piping system - HSC 6.7
❑
❑
❑
❑
❑
None
❑
25290.1(h), 25290.2(8),
Yes
25291(1), 25292(e),
2636(1, (2)
30026
Line leak detectors detect
a 3 gph leak and /or
RD
audible and visual alarm
❑
❑
❑
❑
❑
None
❑
function properly - 23
Yes
CCR 16 2636(0(6),
2666(c)
30027
Turbine shuts down when
a leak is detected or
RD
when line leak detector is
❑
❑
[
❑
❑
❑
None
❑
disconnected - 23 CCR 16
Yes
2666(c)
30025
Pressurized piping able to
detect a 3.0 gph leak
RD
within an hour, and
❑
❑
❑
❑
❑
None
❑
restricts the flow or
Yes
alarms - 23 CCR 16
2636 2
ction Piping
30053
Suction piping sloped to
drain back into storage
RD
tank, one check valve and
❑
❑
❑
❑
❑
None
❑
inspections conducted -
Yes
23 CCR 16 2636(a)(3),
2641(b)
condary Containment
30008
UDC, sumps, and /or
other secondary
containment in good
[�4
❑
❑
❑
❑
❑
None
condition and /or are free
of debris /liquid - HSC 6.7
25290.1, 25290.2, 25291
30047
Secondary containment
maintained tight and has
been confirmed by testing
❑
❑
❑
❑
❑
None
- 23 CCR 16 2662, HSC 6.7
25290.1(c)(2), 25290.2(c)(2),
25291(a), 25292(e)
30060
Entry fittings in secondary
containment for UST
system maintained
❑
❑
❑
❑
❑
None
tight/sealed - 23 CCR 16
2630, 2635(d), 2636(c),
2666
30020
Spill bucket is installed
and has a functional drain
RP
valve or other means to
Pq
❑
❑
❑
❑
❑
None
❑
remove liquid - 23 CCR 16
Yes
2635(b), 2665
Bakersfield Fire Department Prevention
2101 H St
Bakersfield CA. 93301
661 - 326 -3911
n
x
Underground Storage Tank Program
SW Inspection Report
NOTICE TO COWLY/NOTICE OF VIOLATION
olation
Program Requirement
.o
SOC
Comments
No
030
Z
o
z
M
y
o
o>
30054
Spill bucket maintained in
RP
good condition and free of
�
F]
E)
❑
❑
❑
None
❑
debris and /or liquid - 23
Yes
CCR 16 2635(b), 2715(c)(2)
30019
Spill bucket to has a
minimum capacity of five
❑
❑
❑
❑
❑
None
gallons - 23 CCR 16
2635(b), 2665
,erfill
30035
UST system is operated
to prevent unauthorized
RP
release, including spills
[
❑
❑
❑
❑
❑
None
❑
and overfills - HSC 6.7
Yes
25292.1(a)
30036
Overfill prevention system
has not been overridden
RP
and meets overfill
E�
❑
❑
❑
❑
❑
None
❑
requirements - 23 CCR 16
Yes
2635 b (2), 2665
On
Site Records
rtifications
3:0023
Required designated
operators or contractors
maintain a proper and
❑
❑
❑
❑
❑
None
current ICC certification -
23 CCR 16 2715
3:0024
Service technician, installer,
and/ or employee maintain a
❑
❑
❑
❑
❑
None
proper license - 23 CCR 16
2715
30031
Employee or contractor
obtained and maintained
proper manufacturer
[
❑
❑
❑
❑
❑
None
certification - 23 CCR 16
2715
10007
Submit /maintain current
Certificate of Financial
Responsibility /mechanism
of financial assurance - 23
®
❑
❑
❑
❑
❑
None
CCR 16 2711; 23 CCR 18
2808.1, 2809 - 2809.2; HSC
6.7 25292.2; HSC 6.75
25299.30- 25299.34
30007
Positive statement of
compatibility for UST
system components]
❑
❑
❑
❑
❑
submitted and maintained on
site - 23 CCR 16 2631(j)
signated Operator
10004
Copies of DO inspections
for last 12 months and list
of trained employees
❑
❑
❑
❑
❑
None
maintained - 23 CCR 16
2715
Bakersfield Fire Department Prevention
2101 H St
Bakersfield CA. 93301
661 -326 -3911
7„
Underground Storage Tank Program
SW Inspection Report
NOTICE TO COMPLY/NOTICE OF VIOLATION
olation
Program Requirement
o
SOC
Comments
No
>O
a
o
O
a.
6,
a)o
z
O
z
M
0
x
30013
Designated operator
properly conducted the
monthly inspection and
j
❑
❑
❑
❑
❑
None
the reports are complete -
23 CCR 16 2715
30010
DO notified operator of
any condition observed
during the monthly
50
❑
❑
❑
❑
❑
None
inspection that may
require action - 23 CCR 16
2715(d)
30012
DO employee training
performed, current for at
least one employee on
❑
❑
❑
❑
❑
None
site, and a log kept - 23
CCR 16 2715(c)(6), 2715(o
gs
30001
Leak detection alarm
logs, maintenance and
records of appropriate
❑
❑
❑
❑
❑
None
follow -up actions
maintained - 23 CCR 16
2632, 2634, 2712(b
30020
Unburied fuel piping
RD
visually inspected at least
❑
❑
®
❑
❑
❑
None
❑
monthly and log kept -
Yes
HSC 6.7 25281.5(b)(3)
30049
Suction pipe monitored
daily and results logged -
❑
❑
[7
❑
❑
❑
None
23 CCR 16 2643(d)
30057
When SIR results indicate
failure: The facility met all
RD
corrective action
❑
❑
E�
❑
❑
❑
None
❑
requirements - 23 CCR 16
Yes
2646.1(d)
30058
All Statistical Inventory
RD
Reconciliation (SIR)
❑
❑
0
❑
❑
❑
None
❑
requirements met - 23
Yes
CCR 16 2646.1
intenance/Tests
10008
Monitoring, maintenance,
repairs, linings, and
RD
upgrade records
❑
❑
❑
❑
[]
None
❑
maintained for the proper
Yes
time period - 23 CCR 16
2712(b)
Bakersfield Fire Department Prevention
2101 H St
Bakersfield CA. 93301
661 -326 -3911
Underground Storage Tank Program
SW Inspection Report
NOTICE TO COMPLY/NOTICE OF VIOLATION
olation
Program Requirement
m o
SOC
Comments
No
0
a
IM °z
o
z
D
c
�
' —
10002
Records of cathodic
protection systems testing
Q
❑
❑
❑
❑
❑
None
maintained - 23 CCR 16
2635, 2712(b)
icumentation
30033
Failure to maintain on site
an approved monitoring
❑
❑
❑
❑
❑
None
plan - 23 CCR 16 2632,
2634, 2711, 2712(i)
3:0037
Written agreement between
the tank owner and tank
operator to monitor the tank
❑
❑
❑
❑
❑
None
system is maintained - 23
CCR 16 2620(b); HSC 6.7
25284(a)(3)
3:0061
Suspected or actual
unauthorized release
RD
reported in appropriate time
❑
❑
❑
❑
❑
None
❑
frame - HSC 6.7 29294,
Yes
29295
neral Operating Requirements
-mit Condition
/Approval
3:0039
Compliance with all
operating permit conditions
❑
❑
❑
❑
❑
None
- 23 CCR 16 2712; HSC 6.7
25299
3:0059
UST system maintained in
accordance with
�fl
❑
❑
❑
❑
❑
None
exclusionlexemption status -
HSC 6.7 25281.6, 25283.5
3:0014
Owner /Operator received
approval and has
implemented a training
❑
❑
®
❑
❑
❑
None
program at an unstaffed
facility - 23 CCR 16
2715(f)(2)
3:0015
Facility exhibited that the
method used to monitor the
tank meets the monitoring
[
❑
❑
❑
❑
❑
None
methods in 2643(f) - 23
CCR 16 2643
d Tag
3:0045
Red Tag information is
legible and has not been
❑
❑
❑
❑
❑
None
tampered with - 23 CCR 16
2717.1(g)
3.0044
Facility did not allow for
deposit of petroleum into a
UST that has a red tag
❑
❑
[
❑
❑
❑
None
affixed to the fill - 23 CCR
16 2717.1(f)
tall /Repair
Bakersfield Fire Department Prevention
2101 H St
Bakersfield CA. 93301
661- 326 -3911
Underground Storage Tank Program
SW Inspection Report
NOTICE TO COMPLY/NOTICE OF VIOLATION
olation
Program Requirement
,o
SOC
Comments
No
OO
M
a
o
O
a
=
d -moo
z
O
z
M
0
W
0>
3.0066
Repaired and retested the
system due to a failed ELD
test when located within
❑
❑]
❑
❑
❑
None
1000' of public well - HSC
6.7 25292.4(d), 25292.5(c)
50018
Existing SW piping is
constructed of FRP,
RP
cathodically protected steel,
❑
❑
❑
❑
❑
None
❑
or steel clad with FRP - 23
Yes
CCR 16 2666(b); HSC 6.7
25292(e)(2)
50021
Striker plate installed and
positioned correctly - 23
12
❑
❑
❑
❑
❑
None
CCR 16 2631(c), 2662(d)
50004
Corrosion protection
installed for USTs and
RP
cathodic protection system
❑
❑
❑
❑
❑
None
❑
meets the consensus
Yes
standards - 23 CCR 16
2635(a)(2)(A)
JR There were no violations noted for this inspection.
❑This report shall serve as a "NOTICE TO COMPLY" for Minor Violations, and a "NOTICE OF VIOLATION" for
Major violations. You are, hereby, ordered to correct the above noted violations within 30 days, or according to
correction summaries provided. Formal enforcement and /or penalty assessment may be initiated for any
violations noted, and for those not corrected in a timely manner. (NOTE: If this is a preliminary report, a final report
will follow.)
r
Inspectors Siynatu c :� Date:
Inspector: Enter # of Violations: RD: �j_ RP:
Check one box for facility Significant Operational Status (SOC) to be reported to SWRCB and US EPA:
qaSOC with both Release Detection and Release Detection (Facility has no Release Prevention and no Release
'Prevention Violations)
❑ Not in SOC (Facility has both Release Prevention and Release Detection Violations)
❑SOC with Release Detection only (Facility has no Release Detection violations but one or more Release Prevention
violations)
❑ SOC with Release Prevention only (Facility has no Release Prevention violations but one or more Release Detection
violations)