HomeMy WebLinkAbout2016 FMC Fire Safety Insp.BAKERSFIELD FIRE DEPARTMENT
FIRE PREVENTION :" INSPECTION L3 4AVE R S F 1
Prevention Services
" ? HIRE 2101 H Street
T, a' n aacne Bakersfield, CA 93301
Ind
Phone: 661- 326 -3979 •Fax: 661-852-2171
DISTRICT
BLOCK NO.
DATE f r �jr`
,421P?
FEE" .
FACILITY �ADDRESS
CITY, S�TATEy,
- t' �11'i 'f' •' °' r� � .. fl'.. 4r t ,, l -f
FACILITY NAME
�2
MANAGER'S NAME
PF NO.
BUS S OWNER'S 1A ME -,
€mac Cx� `'�A -4, 1k C 4+ X12 p
CI /TY STATE, ZIP
3 =� o C.
PH NO.
BILL TO: (IF DIFFERENT FROM ABOVE) NAME, ADDRESS
CITY, STATE, ZIP
PH NO.
OCC TYPE
. -
-7
OCC LOAD
I /' S"
NO. OF FLOORS
HIGHRISEBLDG
❑ YES MIN O
RISER DATE
IA, -
CORRECT ALL VIOLATIONS VIOLATION
REQUIREMENTS
CHECKED BELOW NO.
Remove and safely dispose of all hazardous refuse and dry vegetation on the above premises
COMBUSTIBLE WASTE / DRY
(CFC 304:1.1)
2
Provide non - combustible containers with tight fitting lids for the storage of combustible waste and
VEGETATION .
rubbish pending its safe disposal. (CFC 304.3:2) Note.: applies to containers over 40 gallons.
3
Relocate combustible storage to provide at least 3 feet clearance around motor fuse box /fire door
COMBUSTIBLE STORAGE
(CFC 605.3)
4'
Relocate fire extinguisher(s) so that they will be in a conspicuous location, hanging on brackets with the
top to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9)
5
Provide and install (amount) approved (type & size) portable fire
EXTINGUISHERS
extinguisher to be immediately, accessible for use in (area)
(CFC TABLE 906.3(1))
6
Re- charge all fire extinguishers. Fire et'uagu.isla:egall be e,, ivd., ast once each year, and /or
after each use, b a person having a valid license or certificate. CFC 906.2
7
Provide and maintain "EXIT" sign(s) with letters 6 or more inches in height over each required exit
SIGNS
(door /window) to fire escape. (CFC 1011)
r,
s
Provide and maintain appropriate numbers on a contrasting background and visible from the street to
F,
indicate the correct address of the building. (CFC 505.1) rrt
9
Repair all (cracks /holes /openings) in plaster, in (location)
FIRE DOORS /..
)
Plastering shall return the surface to its original fire resistive condition. (CFC 703.1). .
FIRE SEPARATIONS
10
Remove /repair (item & location)
Self - closing doors shall be designed to close by gravity, or by the action of mechanical device, or by an
approved smoke and heat sensitive device. Self - closing 'doors shall have no attachments capable of
preventing the operation of the closing device. (CFC 703.2)
11
Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC,1028.3)
EXITS
t
1
12
Provide a contrasting colored and permanently installed electric light over or near required exit
(location) to clearly indicate it .as an exit. (CFC 1006:3)
STORAGE
13
Remove all storage and /or other obstructions from fire escape landings and stairways stair shafts. (Fire
escapes /stair shafts are to be maintained free from obstructions at all times.) (CFC 1003.6)
14
Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved
ELECTRICAL. APPLIANCES
#
electrical outlets where needed. (CFC 605.5)
15
Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet)
(CFC 605.4)
OUTDOOR BURNING
6
Recreational fires or open burning. (CFC 307.1)
FIREWORKS
17
Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.).
OTHER
$
1
�;
H F�tF -e tG• fiv:L
CORRECTION DATE
Correct the violations noted above by:
A �"
La jq " f
LEGEND:
C.F.C. CALIFORNIA FIRE CODE
C.B.C. CALIFORNIA BUILDING.CODE
CUSTOMER: � a
B.M.C. BAKERSFIELD MUNICIPAL CODE.
(Signature) t (Please Print Name Legibly, Title)
N.F.P.A. NATIONAL FIRE PROTECTION
ASSOCIATION
INSPECTOR: NO.:
`'+
N.E.C. NATIONAL ELECTRIC CODE