Loading...
HomeMy WebLinkAboutHAZ-WASTE INSP 1/21/2015HAZARDOUS WASTE g3, BAKERSFIELD FIRE DEPARTMENT UNIFIED PROGRAM : CONSOLIDATED FORMS Prevention Services F /RE 2101 H Street SMALL QUANTITY HAZARDOUS PART T Bakersfield, CA 93301 WASTE GENERATOR INSPECTION Phone: 661- 326 -3979 oFax: -661- 852 -2171. Facility Name: ." C .r ' ` %.. ° /.` ' r ' h Date: i Site Address: r - ; r Time In: ,r`': Time Out: r IDOwner /Operator: ' r ` Phone. f _. EPA Tune ofInspection . D Routine 0 Re- inspection/Follow -up ' - ombined. Routir%i on Joint Inspection 0 Complajnt Focused [] Other CONSENT TO INSPECT GRANT BY (Name / Title): t ^,7 - +-r " """ Inspection may involve obtaining photographs, review and coOg ofrecords, and deterlrnnation ofcompliance with hazardous waste handling requirements. C V 1 j(ullL.- V 19 U V). 1V1111V1 V 1V1LLL-AA HAZARDOUS WASTE REQUIREMENT N/A CERS Violation # COMMENTS Recordkee in documentation Generator has an EPA ID number [HSC 25143.131 3010002 Hazardous waste determination made for all wastes 0 Analysis ;Q Generator Knowledge [CCR 66262.401 3030005 X Contin enc lplan information posted near p one [CCR 66262.34(4)(2)] 3010022 Facility personnel demonstrate training /awareness [CCR 66262.34(d)(2)] 3020001 Manifests /Consolidated Manifest receipts complete [CCR 66262.23(a)] Blue copy(s) ofmanifest mailed to DTSC [CCR. 66262.23(a)(4)] 3010008 3010011 Bills of Lading/receipts available [CCR 66262.40(a)] 3010010 LDRs available and complete . [CCR 66268.7(a)] Yy'- 3030006 Onsite recycling reported using UPCF [HSC 25143. 101 3030001 Container /tank management Containers are in good condition [CCR 66262.34(d)(2)] Containers are closed except when adding/removing [CCR66262.34(d)(2A. Satellite containers at or near point ofgeneration [CCR 66262.34(e)(1)(A)]'._ Empty containers are empty [CCR 66262.34(f)] Containers inspected weekly [CCR 66262.34(d)(2)] 3030013 3030017 3030007 3030019 Tanks ins ected daily [CCR 66262.34(4)(2), 40CFR 265.2011 X 3030027 One container per waste stream at satellite area [CCR 66262.34(d)(2)] 3030022 Exclude recyclable materials stored in accordance with local ordinance/hazardous materials codes [HSC 25143.101 3010016 Accumulation Time Limits Waste is accumulated not more than 90A $0470 [CCR 66262.34(d)], -` 3030010 Empty containers managed within one ear ,,[CCR 66262,34(0)1' 3030010 ra• 'd e L - -7 /7 Universal waste accumulated less than one.year. [CCR 66273.15(a)] Used oil filters offsite within 180 (1,year, <l,tofi) "' [CCR 66266.130(c)(4)] f o.' 3030011 3030004 1 Vf'f Pb -acid batteries offsite within 189'(1 yr. < I ton) [CCR66266.81(a)(3)] ` 3030002 J, Labeling/Marking Containers are properly labeled [66262.34(f)] Excluded recyclable materials marked properly [HSC 25143.9(a)] ee, 3030007 3050005 Universal waste container properly labeled (CCR 66273.341 3030008 e Used oil filters marked "drained used oil filters" [CCR 66266.1301 ,: 3030004 Date written on spent lead -acid batteries [CCR 66266.81(a)(6)(B)] 3030003 Used Oil" marked on all used oil tanks /containers [CCR 66279.21(1)] 3030007 Tank marked with "haz waste" , contents, start date [66262.34(f)] 3030007 Treatment, Transport and Disposal/Other . Have ermit/authorization to do treatment [HSC 25136.2] 3040003 Waste sent with authorized transport (gen. eligible [CCR 66263.411 ,. 3050001 Waste disposed of to authorized point/ party [HSC 25189,5(a)]' 3050002 Failed to properly handle appliance wastes [HSC 25212(a)] 1 Fire Protection - [66262.34(d)(2)] 3030032 Print and sigthin this boxfor receipt of this report. Signature does not imply agreement with findings only receipt of report. INSPECTOR' /- POST INSPECTION INSTRUCTIONS: Correct the violation(s) noted above by Signature (that all violations have been - corrected as noted) Within 5 days of correcting all of the violations, sign andreturn a copy of this page to: Bakersfield Fire Dept., Prevention Services, 2101 H St. Bakersfield, CA 93301 Date FD2171 (Rev 9/14) White — Business Copy Yellow- Station Copy Pink- Prevention Services Copy HAZARDOUS WASTE g3, BAKERSFIELD FIRE DEPARTMENT UNIFIED PROGRAM : CONSOLIDATED FORMS Prevention Services F /RE 2101 H Street SMALL QUANTITY HAZARDOUS PART T Bakersfield, CA 93301 WASTE GENERATOR INSPECTION Phone: 661- 326 -3979 oFax: -661- 852 -2171. Facility Name: ." C .r '� ` %.. °� /.` '� r 'h Date: i Site Address: r - ; r Time In: ,r`': Time Out: r ID Owner /Operator: ' r ` Phone. f � _. EPA Tune of Inspection . D Routine 0 Re- inspection/Follow -up �' - ombined. Routir%�i on Joint Inspection 0 Complajnt Focused [] Other ''[_"CONSENT TO INSPECT GRANT BY (Name / Title): t �^,7 - �� �+-r� �" """ " Inspection may involve obtaining photographs, review and coOg of records, and deterlrnnation of compliance with hazardous waste handling requirements. C V 1 j(ullL.- V 19 U V). 1V1111V1 V 1V1LLL-AA HAZARDOUS WASTE REQUIREMENT N/A CERS Violation # COMMENTS Recordkee in documentation Generator has an EPA ID number [HSC 25143.131 3010002 Hazardous waste determination made for all wastes 0 Analysis ;Q Generator Knowledge [CCR 66262.401 3030005 `X Contin enc l plan information posted near p one [CCR 66262.34(4)(2)] 3010022 Facility personnel demonstrate training /awareness [CCR 66262.34(d)(2)] 3020001 Manifests /Consolidated Manifest receipts complete [CCR 66262.23(a)] Blue copy(s) of manifest mailed to DTSC [CCR. 66262.23(a)(4)] °,? 3010008 3010011 Bills of Lading/receipts available [CCR 66262.40(a)] 3010010 LDRs available and complete . [CCR 66268.7(a)] Yy'- 3030006 Onsite recycling reported using UPCF [HSC 25143. 101 3030001 Container /tank management .: Containers are in good condition [CCR 66262.34(d)(2)] Containers are closed except when adding/removing [CCR66262.34(d)(2A. Satellite containers at or near point of generation [CCR 66262.34(e)(1)(A)]'._ Empty containers are empty [CCR 66262.34(f)] Containers inspected weekly [CCR 66262.34(d)(2)] 3030013 3030017 3030007 3030019 Tanks ins ected daily [CCR 66262.34(4)(2), 40CFR 265.2011 X 3030027 One container per waste stream at satellite area [CCR 66262.34(d)(2)] 3030022 Exclude recyclable materials stored in accordance with local ordinance/hazardous materials codes [HSC 25143.101 3010016 Accumulation Time Limits Waste is accumulated not more than 90A $0470 [CCR 66262.34(d)], ­` 3030010 Empty containers managed within one ear ,,[CCR 66262,34(0)1' 3030010 ra• 'd e L - -7 /7 Universal waste accumulated less than one.year. [CCR 66273.15(a)] Used oil filters offsite within 180 (1,year, <l,tofi) "' [CCR 66266.130(c)(4)] f o.' 3030011 3030004 1 �V f'f Pb -acid batteries offsite within 189'(1 yr. < I ton) [CCR66266.81(a)(3)] ` 3030002 J✓, Labeling/Marking Containers are properly labeled [66262.34(f)] Excluded recyclable materials marked properly [HSC 25143.9(a)] ee, 3030007 3050005 Universal waste container properly labeled (CCR 66273.341 3030008 e Used oil filters marked "drained used oil filters" [CCR 66266.1301 ,: 3030004 Date written on spent lead -acid batteries [CCR 66266.81(a)(6)(B)] 3030003 "Used Oil" marked on all used oil tanks /containers [CCR 66279.21(1)] 3030007 .� Tank marked with "haz waste" , contents, start date [66262.34(f)] 3030007 Treatment, Transport and Disposal/Other . Have ermit/authorization to do treatment [HSC 25136.2] 3040003 Waste sent with authorized transport (gen. eligible [CCR 66263.411 ,. ``�" 3050001 Waste disposed of to authorized point/ party [HSC 25189,5(a)]' 3050002 Failed to properly handle appliance wastes [HSC 25212(a)] 1� Fire Protection - [66262.34(d)(2)] 3030032 Print and sigthin this box for receipt of this report. Signature does not imply agreement with findings only receipt of report. INSPECTOR' /- POST INSPECTION INSTRUCTIONS: • Correct the violation(s) noted above by Signature (that all violations have been - corrected as noted) • Within 5 days of correcting all of the violations, sign and return a copy of this page to: Bakersfield Fire Dept., Prevention Services, 2101 H St. Bakersfield, CA 93301 Date FD2171 (Rev 9/14) White — Business Copy Yellow- Station Copy Pink- Prevention Services Copy