CORRECT ALL VI6LATIONS VIOLATION
. REQUIREMENTS
CHECKED BELOW NO.
-
1:
Remove.and safely dispose of all hazardous refuse and dry. vegetation .on the, above premises (CFC
COMBUSTIBLE WASTE / DRY
3 O 4.1.1)
VEGETATION
1
2
Provide no,n- combustible containers with tight fitting: lids for the sto•rage_of combustible waste and
rubbish pending its safe disposal.: (CFC 304.3.2) Note: applies -to containers over 40 gallons. .
COMBUSTIBLE STORAGE .
3
Relocate combustible storage to provide at least 3 feet clearance around motor fuse box /fire door (CFC
605.3,)
4
Relocate. fire extinguisher(s) so than they will be in a conspicuous location, hanging on brackets with, the
top to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9)
EXTINGUISHERS
5
Provide and install (amount) _ —__- approved (type & size) _ _______ _________ portable fire
extinguisher to be immediately accessible for use in (area) _ ______ __ ______ ___ ___ __ _ __ _ __ (CFC
TABLE.906.3(1))
6
Re- charge all fire extinguishers. Fire extinguishers shall be serviced. at least once each year, and /or
after each use, by a person having a valid License or certificate. (CFC 906.2')
Provide and 'maintain "EXIT" sign(s) with letters 6 or more inches in height over each required exit
SIGNS
'(door. /wi_ndow) to fire escape. (CFC 1011)
g
Provide and maintain appropriate numbers on a contrasting background and visible. from the street to
indicate the correct address of the building. (CFC 505..1)
g
Repair all ('cracks /holes /openings) in plaster in (location) ---- __� - - - - ---
FIRE DOORS/
Plastering shall return tHe. surface to its original 'fire resistive condition. '(CFC 703.1).
FIRE SEPARATIONS
10
'Remove/repair - (item location) --------=------------------------------------- - - - - =- - --
,&
Self closing doors shall be designed to close by gravity; or :by the action of a mechanical device, or by an
approved smoke an.d' heat sensitive device. Self - closing doors shall have no attachments. capable of
preventing the operation of the,.closing 'device. (CFC 703.2)
11
Remove611 .obstruction from hallways.. 'Maintain all means of egress free of any storage. (CFC 1028.3)
EXITS
12
...Provide :a' contrasting• colored and permanently installed electric light over o,r near _ required exit
(locatio:n) _`_ _ — to clearly indicate..it as an exit. .(CFC.10'06:3) "
.
Remove all :storage and /or other obstructions from .fire "escape' landings and .stairways stair shafts: (Fire
STORAGE
13
.. escapes /stair `shafts are to be maintained free from. obstructions at all times.)` (CFC 1003.6)
14
Extension cords shaII not be used in lieu of permanent approved wiring. install additional approved
ELECTRICAL APPLIANCES
electrical Outlets where needed. '.(CFC 605..5)
15
Remove mu i Iti ple, attachment. cords from -specific electrical convenience. outlet {one plug per outlet). (CFC
605,4)
OUTDOOR BURNING'
16
Recreational fires or open burnin . CFC 307.1
FIREWORKS
17 ,
Violations of.Section (CFC 5608..1) & 8.44.040 (B.M.C.).
OTHER _
18
di l .%t r .... -i F �R t ,! 3 • t= t`1 tr''.r v t e�} t t f rte. 1!
CORRECTION DATE
7 correct the v' ions noted above_ by: