Loading...
HomeMy WebLinkAbout2016 FMC RESULTS (SOUTH)MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of CaliforniaAuthority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A.General Information Facility Name:Bldg. No.: Site Address:City:Zip: Facility Contact Person: Contact Phone No.: Make/Model of Monitoring System:Date of Testing/Servicing: B.Inventory of Equipment Tested/Certified Check the appropriate boxes to indicate specific equipment inspected/serviced: Tank ID:Tank ID: In-Tank Gauging Probe.Model:In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model:Annular Space or Vault Sensor.Model: Piping Sump / Trench Sensor(s).Model:Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model:Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model:Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Electronic LineLeak Detector.Model: Tank Overfill / High-Level Sensor.Model:Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2).Other (specify equipment type and model in Section E on Page 2). Tank ID:Tank ID: In-Tank Gauging Probe.Model:In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model:Annular Space or Vault Sensor.Model: Piping Sump / TrenchSensor(s).Model:Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model:Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model:Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Electronic Line Leak Detector.Model: Tank Overfill / High-Level Sensor.Model:Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2).Other (specify equipment type and model in Section E on Page 2). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C.Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers’ guidelines. Attached to this Certification is information (e.g. manufacturers' checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report;(check all that apply):System set-up Alarm history report Technician Name (print):Signature: Certification No.:License. No.:804904 Testing Company Name:Confidence UST Services, Inc.Phone No.:(800)339-9930 Site Address:Date of Testing/Servicing: Page 1 of 3 #7781/Fastrip#22(South) 4013SouthHStreetBakersfield93309 OmeroGarcia (661)393-7000 Veeder-RootTLS-350 07/13/2016 12,000gal.Regular1 847390-107 794390-420 794380-208 FX1V 847390-107 12,000gal.Regular2(Siphon) 847390-107 794390-420 794380-208 FX1V 847390-107 12,000gal.Super 847390-107 794390-420 794380-208 FX1V 847390-107 12,000gal.Diesel 847390-107 794390-420 794380-208 FX1DV 847390-107 1-2 794380-208 3-4 794380-208 5-6 794380-208 794380-208 7-8 AustinSterling B42599 4013SouthHStreet Bakersfield,CA93304 07/13/2016 794380-208 794380-208 Monitoring System Certification D.Results of Testing/Servicing Software Version Installed: Complete the following checklist: Yes No*Isthe audible alarm operational? Yes No*Is the visual alarm operational? Yes No*Were all sensors visually inspected, functionally tested, and confirmed operational? Yes No*Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* N/A If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) operational? Yes No* N/A For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) Sump/Trench Sensors; Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection? Yes; No. Yes No* N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent oftank capacity does the alarm trigger? % Yes*NoWas any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes*NoWas liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) Product; Water. If yes, describe causes in Section E, below. Yes No*Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable Yes No*Is all monitoring equipment operational per manufacturer’s specifications? * In Section E below, describe how and when these deficiencies were or will be corrected. E.Comments: Page 2 of 3 330.02 90 Monitoring System Certification F.In-Tank Gauging / SIR Equipment: Check this box if tank gauging is used only for inventory control. Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: Yes No*Has all input wiring been inspected for proper entry and termination, including testing for ground faults? Yes No*Were all tank gauging probes visually inspected for damage and residue buildup? Yes No*Was accuracy of system product level readings tested? Yes No*Was accuracy of system water level readings tested? Yes No*Were all probes reinstalled properly? Yes No*Were all items on the equipment manufacturer’s maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. G.Line Leak Detectors (LLD):Check this box if LLDs are not installed. Complete the following checklist: Yes No* N/A For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? (Check all that apply)Simulated leak rate: 3 g.p.h.; 0.1 g.p.h ; 0.2 g.p.h. Yes No*Were all LLDs confirmed operational and accurate within regulatory requirements? Yes No*Was the testing apparatus properly calibrated? Yes No* N/A For mechanical LLDs, does the LLD restrict product flow if it detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? Yes No* N/A For electronic LLDs, have all accessible wiring connections been visually inspected? Yes No*Were all items on the equipment manufacturer’s maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. H.Comments: Page 3 of 3 Leak Detector Test Results Sheet Customer Address: Work Order: Site Address: Test Date: Site Contact: Phone: Technician: Phone: 800-339-9930 ICC No.: Product Type LLD Type Model Serial No. Check Valve Holding Pressure Bleed Off ML. Leak Rate Tested: Pass/Fail 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi Technician Name: Technician No.: Signature: Date: JacoHill P.O.Box82515 Bakersfield,CA93380-2515 36817 07/13/2016 8339953-UT Regular1 Mechanical FX1V AustinSterling (661)393-7000OmeroGarcia Bakersfield,CA93304 4013SouthHStreet #7781/Fastrip#22(South) 14 psi135 ml Pass FX1VMechanicalRegular2 13 psi130 ml Pass FX1VMechanicalPremium 10 psi125 ml Pass FX1DVMechanicalDiesel AustinSterling 8339953-UT 07/13/2016 Jaco 7781 MC system setup Responses Received: 200 FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 JUL 13, 2016 1:18 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNL 1 2938 32.61 0.0 83.6 9124 2 UNL 2 3442 36.56 0.0 81.7 8620 3 PNL 2779 31.33 0.8 83.3 9283 4 DIESEL 3355 35.89 0.0 81.7 8707 I90500 JUL 13, 2016 1:18 PM SOFTWARE REVISION LEVEL VERSION 333.02 SOFTWARE# 346333-100-C CREATED - 12.08.10.11.22 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 JUL 13, 2016 1:18 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 JUL 13, 2016 1:18 PM SHIFT TIME 1 : DISABLED I50202 JUL 13, 2016 1:18 PM SHIFT TIME 2 : DISABLED I50203 JUL 13, 2016 1:18 PM SHIFT TIME 3 : DISABLED I50204 JUL 13, 2016 1:18 PM SHIFT TIME 4 : DISABLED I54600 JUL 13, 2016 1:18 PM TANK PER TST NEEDED WRN: DISABLED I54900 JUL 13, 2016 1:18 PM TANK ANN TST NEEDED WRN: DISABLED I55300 JUL 13, 2016 1:18 PM LINE RE-ENABLE METHOD PASS LINE TEST I55600 JUL 13, 2016 1:18 PM LINE PER TST NEEDED WRN: DISABLED I55900 JUL 13, 2016 1:18 PM LINE ANN TST NEEDED WRN: DISABLED I50D00 JUL 13, 2016 1:18 PM PRINT TC VOLUMES ENABLED I50E00 JUL 13, 2016 1:18 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 JUL 13, 2016 1:18 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 JUL 13, 2016 1:18 PM H-PROTOCOL DATA FORMAT HEIGHT I51A01 JUL 13, 2016 1:18 PM DAYLIGHT SAVING TIME ENABLED ON I51B00 JUL 13, 2016 1:18 PM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 JUL 13, 2016 1:18 PM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 JUL 13, 2016 1:18 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 JUL 13, 2016 1:18 PM TANK CHART SECURITY DISABLED I5BD00 JUL 13, 2016 1:18 PM CUSTOM ALARM LABELS DISABLED I56000 JUL 13, 2016 1:18 PM MASS/DENSITY DISABLED I88101 JUL 13, 2016 1:18 PM PORT SETTINGS: COMM BOARD : 1 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88102 JUL 13, 2016 1:18 PM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 JUL 13, 2016 1:18 PM PORT SETTINGS: COMM BOARD : 3 (EDIM ) RS-232 SECURITY CODE : DISABLED I88104 JUL 13, 2016 1:18 PM I88105 JUL 13, 2016 1:18 PM I88106 JUL 13, 2016 1:18 PM I52000 JUL 13, 2016 1:18 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE ??? 13, 2016 DISABLED 2 ON DATE ??? 13, 2016 DISABLED 3 ON DATE ??? 13, 2016 DISABLED 4 ON DATE ??? 13, 2016 DISABLED 5 ON DATE ??? 13, 2016 DISABLED 6 ON DATE ??? 13, 2016 DISABLED 7 ON DATE ??? 13, 2016 DISABLED 8 ON DATE ??? 13, 2016 DISABLED I60100 JUL 13, 2016 1:18 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL 1 ON 2 UNL 2 ON 3 PNL ON 4 DIESEL ON I60200 JUL 13, 2016 1:18 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL 1 2 UNL 2 3 PNL 4 DIESEL I60300 JUL 13, 2016 1:18 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL 1 1 2 UNL 2 2 3 PNL 3 4 DIESEL 4 I60900 JUL 13, 2016 1:18 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL 1 0.000700 2 UNL 2 0.000700 3 PNL 0.000700 4 DIESEL 0.000450 I60700 JUL 13, 2016 1:18 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL 1 111.50 2 UNL 2 111.50 3 PNL 111.50 4 DIESEL 111.50 I60A00 JUL 13, 2016 1:18 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNL 1 1 PT 12062 2 UNL 2 1 PT 12062 3 PNL 1 PT 12062 4 DIESEL 1 PT 12062 I60400 JUL 13, 2016 1:18 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 2 UNL 2 12062 3 PNL 12062 4 DIESEL 12062 I60500 JUL 13, 2016 1:18 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 0 0 0 2 UNL 2 12062 0 0 0 3 PNL 12062 0 0 0 4 DIESEL 12062 0 0 0 I60600 JUL 13, 2016 1:18 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 UNL 2 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PNL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 DIESEL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 JUL 13, 2016 1:18 PM TANK PRODUCT LABEL METER DATA 1 UNL 1 NO 2 UNL 2 NO 3 PNL NO 4 DIESEL NO I62F00 JUL 13, 2016 1:18 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNL 1 4.0 IN. 2 UNL 2 4.0 IN. 3 PNL 4.0 IN. 4 DIESEL 4.0 IN. I62700 JUL 13, 2016 1:18 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 2.0 2 UNL 2 2.0 3 PNL 2.0 4 DIESEL 2.0 I64200 JUL 13, 2016 1:18 PM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNL 1 LOW 2 UNL 2 LOW 3 PNL LOW 4 DIESEL LOW I62400 JUL 13, 2016 1:18 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 3.0 2 UNL 2 3.0 3 PNL 3.0 4 DIESEL 3.0 I62800 JUL 13, 2016 1:18 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 2 UNL 2 12062 3 PNL 12062 4 DIESEL 12062 I62300 JUL 13, 2016 1:18 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 10856 2 UNL 2 10856 3 PNL 10856 4 DIESEL 10856 I62200 JUL 13, 2016 1:18 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 11459 2 UNL 2 11459 3 PNL 11459 4 DIESEL 11459 I62900 JUL 13, 2016 1:18 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1809 2 UNL 2 1809 3 PNL 1809 4 DIESEL 1809 I62100 JUL 13, 2016 1:18 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 500 2 UNL 2 500 3 PNL 500 4 DIESEL 500 I62600 JUL 13, 2016 1:18 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 UNL 2 99 3 PNL 99 4 DIESEL 99 I62500 JUL 13, 2016 1:18 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 UNL 2 99 3 PNL 99 4 DIESEL 99 I60800 JUL 13, 2016 1:18 PM TANK TILT TANK PRODUCT LABEL INCHES 1 UNL 1 2.00 2 UNL 2 2.00 3 PNL 0.00 4 DIESEL 0.00 I60B00 JUL 13, 2016 1:18 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 JUL 13, 2016 1:18 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNL 1 0.00 2 UNL 2 0.00 3 PNL 0.00 4 DIESEL 0.00 I61200 JUL 13, 2016 1:18 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL 1 2 NONE 2 UNL 2 1 NONE 3 PNL NONE NONE 4 DIESEL NONE NONE I63600 JUL 13, 2016 1:18 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 120 2 UNL 2 120 3 PNL 120 4 DIESEL 120 I62A00 JUL 13, 2016 1:18 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 120 2 UNL 2 120 3 PNL 120 4 DIESEL 120 I62C00 JUL 13, 2016 1:18 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNL 1 STANDARD 2 UNL 2 STANDARD 3 PNL STANDARD 4 DIESEL STANDARD I62D00 JUL 13, 2016 1:18 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNL 1 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 UNL 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 PNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 JUL 13, 2016 1:18 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNL 1 OFF OFF 2 UNL 2 OFF OFF 3 PNL OFF OFF 4 DIESEL OFF OFF I63000 JUL 13, 2016 1:18 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNL 1 OFF 2 UNL 2 OFF 3 PNL OFF 4 DIESEL OFF I63200 JUL 13, 2016 1:18 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNL 1 OFF 2 UNL 2 OFF 3 PNL OFF 4 DIESEL OFF I61000 JUL 13, 2016 1:18 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNL 1 1 2 UNL 2 1 3 PNL 1 4 DIESEL 1 I63A00 JUL 13, 2016 1:18 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNL 1 10.00% 2 UNL 2 10.00% 3 PNL 10.00% 4 DIESEL 10.00% I61100 JUL 13, 2016 1:18 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JAN 16, 2006 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 JUL 13, 2016 1:19 PM CSLD PROBABLITY OF DETECTION I61400 JUL 13, 2016 1:19 PM CSLD CLIMATE FACTOR I61600 JUL 13, 2016 1:19 PM TANK PRODUCT LABEL CAL UPDATE 1 UNL 1 IMMEDIATE 2 UNL 2 IMMEDIATE 3 PNL IMMEDIATE 4 DIESEL IMMEDIATE I61A00 JUL 13, 2016 1:19 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNL 1 DISABLED 2 UNL 2 DISABLED 3 PNL DISABLED 4 DIESEL DISABLED I61B00 JUL 13, 2016 1:19 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 JUL 13, 2016 1:19 PM CSLD REPORT ONLY I62B00 JUL 13, 2016 1:19 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNL 1 ??? 0, 0 2 UNL 2 ??? 0, 0 3 PNL ??? 0, 0 4 DIESEL ??? 0, 0 I63300 JUL 13, 2016 1:19 PM LEAK TEST REPORT FORMAT: NORMAL I63400 JUL 13, 2016 1:19 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 0 2 UNL 2 0 3 PNL 0 4 DIESEL 0 I63500 JUL 13, 2016 1:19 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1 2 UNL 2 1 3 PNL 1 4 DIESEL 1 I63900 JUL 13, 2016 1:19 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNL 1 END FACTOR: NONE 2 UNL 2 END FACTOR: NONE 3 PNL END FACTOR: NONE 4 DIESEL END FACTOR: NONE I78000 JUL 13, 2016 1:19 PM I77700 JUL 13, 2016 1:19 PM I77800 JUL 13, 2016 1:19 PM I78C00 JUL 13, 2016 1:19 PM I78300 JUL 13, 2016 1:19 PM I78F00 JUL 13, 2016 1:19 PM I78700 JUL 13, 2016 1:19 PM I70200 JUL 13, 2016 1:19 PM LIQUID LABEL DEVICE LABEL 1 UNL 1 STP 2 UNL 1 ANN 3 DIESEL STP 4 DIESEL ANN 5 REG2 STP 6 REG 2 ANN 7 SUPER STP 8 SUPER ANN 9 DISP 1-2 10 DISP 7-8 11 DISP 5-6 12 DISP 3-4 13 NO.TRANS 14 SO.TRANS 15 16 I70300 JUL 13, 2016 1:19 PM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL 1 STP TRI-STATE (SINGLE FLOAT) 2 UNL 1 ANN NORMALLY CLOSED 3 DIESEL STP TRI-STATE (SINGLE FLOAT) 4 DIESEL ANN TRI-STATE (SINGLE FLOAT) 5 REG2 STP TRI-STATE (SINGLE FLOAT) 6 REG 2 ANN TRI-STATE (SINGLE FLOAT) 7 SUPER STP TRI-STATE (SINGLE FLOAT) 8 SUPER ANN TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 7-8 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 3-4 TRI-STATE (SINGLE FLOAT) 13 NO.TRANS TRI-STATE (SINGLE FLOAT) 14 SO.TRANS TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 JUL 13, 2016 1:19 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL 1 STP STP SUMP 2 UNL 1 ANN ANNULAR SPACE 3 DIESEL STP STP SUMP 4 DIESEL ANN ANNULAR SPACE 5 REG2 STP STP SUMP 6 REG 2 ANN ANNULAR SPACE 7 SUPER STP STP SUMP 8 SUPER ANN ANNULAR SPACE 9 DISP 1-2 DISPENSER PAN 10 DISP 7-8 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 3-4 DISPENSER PAN 13 NO.TRANS OTHER SENSORS 14 SO.TRANS OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 JUL 13, 2016 1:19 PM I74300 JUL 13, 2016 1:19 PM I74400 JUL 13, 2016 1:19 PM I74700 JUL 13, 2016 1:19 PM I74800 JUL 13, 2016 1:19 PM I74900 JUL 13, 2016 1:19 PM I7BC00 JUL 13, 2016 1:19 PM I80200 JUL 13, 2016 1:19 PM I80300 JUL 13, 2016 1:19 PM I80400 JUL 13, 2016 1:19 PM I80700 JUL 13, 2016 1:19 PM RELAY LABEL DEVICE LABEL 1 UNL 1 2 PNL 3 DIESEL 4 OVERFILL ALARM I80900 JUL 13, 2016 1:19 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL 1 NORMALLY OPEN 2 PNL NORMALLY OPEN 3 DIESEL NORMALLY CLOSED 4 OVERFILL ALARM NORMALLY OPEN I80B00 JUL 13, 2016 1:19 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 1 2 PNL 3 3 DIESEL 4 4 OVERFILL ALARM NONE I80A00 JUL 13, 2016 1:19 PM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL 1 PUMP CONTROL OUTPUT 2 PNL PUMP CONTROL OUTPUT 3 DIESEL STANDARD 4 OVERFILL ALARM STANDARD I80C00 JUL 13, 2016 1:19 PM I80800 JUL 13, 2016 1:19 PM RELAY SETUP REPORT R 1:UNL 1 TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SHORT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:PNL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 5:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 5:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 5:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DIESEL TYPE: STANDARD NORMALLY CLOSED TANK #: 4 LIQUID SENSOR ALMS L 3:FUEL ALARM L 7:FUEL ALARM L10:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 3:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 3:SHORT ALARM L 7:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM I79000 JUL 13, 2016 1:19 PM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 JUL 13, 2016 1:19 PM I72300 JUL 13, 2016 1:19 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 UNKNOWN 02 F.M DISP 1-2 AIR FLOW METER 03 F.M DISP 3-4 AIR FLOW METER 04 F.M DISP 5-6 AIR FLOW METER 05 F.M DISP 7-8 AIR FLOW METER 06 V.P. 1-2 VAPOR PRESSURE 07 UNKNOWN 08 VP 1-2 VAPOR PRESSURE 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN I72A00 JUL 13, 2016 1:20 PM VACUUM SENSOR VOLUME DEVICE LABEL VOLUME IV4E00 JUL 13, 2016 1:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 JUL 13, 2016 1:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 JUL 13, 2016 1:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 VAPOR PROCESSOR TYPE NONE IV4700 JUL 13, 2016 1:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 JUL 13, 2016 1:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ACCEPT HIGH ORVR: YES IV4A00 JUL 13, 2016 1:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3 IV4B00 JUL 13, 2016 1:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 JUL 13, 2016 1:20 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 JUL 13, 2016 1:20 PM ISD VERSION: 01.04 Jaco 7781 MC alarm history before Responses Received: I10200 JUL 13, 2016 1:15 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39605 39587 2 4 PROBE / G.T. 163800 163749 3 INTERSTITIAL BD 202524 202270 4 INTERSTITIAL BD 201886 201676 5 UNUSED 4904311 4894356 6 UNUSED 4903408 4891325 7 UNUSED 4904752 4892314 8 UNUSED 4902715 4893451 9 STP SENSE BOARD 33209 33195 10 UNUSED 4900671 4895104 11 RELAY BOARD 14993 15000 12 UNUSED 4903905 4894241 13 UNUSED 4902876 4897209 14 UNUSED 4904346 4892873 15 UNUSED 4903695 4895125 16 UNUSED 4903296 4894536 COMM 1 RS232 SERIAL BD 15035 15042 COMM 2 RS232 SERIAL BD 15056 15042 COMM 3 ELEC DISP INT. 101790 101700 COMM 4 UNUSED 4903359 4892915 COMM 5 UNUSED 4901196 4894789 COMM 6 UNUSED 4900839 4894136 I90200 JUL 13, 2016 1:15 PM SOFTWARE REVISION LEVEL VERSION 333.02 SOFTWARE# 346333-100-C CREATED - 12.08.10.11.22 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUL 13, 2016 1:15 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 5 STP SUMP REG2 STP FUEL ALARM CLEAR 7-11-16 11:26AM L 5 STP SUMP REG2 STP FUEL ALARM ALARM 7-11-16 11:23AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 7-08-16 2:46PM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM CLEAR 7-08-16 2:46PM L 2 ANNULAR UNL 1 ANN FUEL ALARM CLEAR 7-08-16 2:46PM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM CLEAR 7-08-16 2:46PM L 7 STP SUMP SUPER STP SENSOR OUT ALARM CLEAR 7-08-16 2:46PM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 7-08-16 2:46PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 7-08-16 2:46PM L 6 ANNULAR REG 2 ANN SENSOR OUT ALARM CLEAR 7-08-16 2:46PM L 5 STP SUMP REG2 STP SENSOR OUT ALARM CLEAR 7-08-16 2:46PM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 7-08-16 2:46PM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 7-08-16 2:46PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 7-08-16 2:46PM L 2 ANNULAR UNL 1 ANN FUEL ALARM ALARM 7-08-16 2:42PM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM ALARM 7-08-16 2:42PM L 7 STP SUMP SUPER STP SENSOR OUT ALARM ALARM 7-08-16 2:42PM L 6 ANNULAR REG 2 ANN SENSOR OUT ALARM ALARM 7-08-16 2:42PM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM ALARM 7-08-16 2:42PM L 5 STP SUMP REG2 STP SENSOR OUT ALARM ALARM 7-08-16 2:42PM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 7-08-16 2:42PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 7-08-16 2:42PM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 7-08-16 2:42PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM ALARM 7-08-16 2:42PM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 7-08-16 2:42PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 7-08-16 2:42PM T 2 TANK UNL 2 PROBE OUT CLEAR 7-08-16 2:41PM T 2 TANK UNL 2 PROBE OUT ALARM 7-08-16 2:38PM T 2 TANK UNL 2 MAX PRODUCT ALARM CLEAR 7-08-16 2:37PM T 2 TANK UNL 2 MAX PRODUCT ALARM ALARM 7-08-16 2:37PM T 1 TANK UNL 1 PROBE OUT CLEAR 7-08-16 2:36PM L 2 ANNULAR UNL 1 ANN FUEL ALARM CLEAR 7-08-16 2:34PM T 1 TANK UNL 1 PROBE OUT ALARM 7-08-16 2:32PM T 1 TANK UNL 1 MAX PRODUCT ALARM CLEAR 7-08-16 2:32PM T 1 TANK UNL 1 MAX PRODUCT ALARM ALARM 7-08-16 2:32PM L 2 ANNULAR UNL 1 ANN FUEL ALARM ALARM 7-08-16 2:31PM L 2 ANNULAR UNL 1 ANN FUEL ALARM CLEAR 7-08-16 2:30PM L 8 ANNULAR SUPER ANN FUEL ALARM CLEAR 7-08-16 2:25PM L 2 ANNULAR UNL 1 ANN FUEL ALARM ALARM 7-08-16 2:23PM L 2 ANNULAR UNL 1 ANN FUEL ALARM CLEAR 7-08-16 2:23PM T 3 TANK PNL PROBE OUT CLEAR 7-08-16 2:16PM T 3 TANK PNL PROBE OUT ALARM 7-08-16 2:13PM T 3 TANK PNL MAX PRODUCT ALARM CLEAR 7-08-16 2:12PM T 3 TANK PNL MAX PRODUCT ALARM ALARM 7-08-16 2:12PM T 4 TANK DIESEL PROBE OUT CLEAR 7-08-16 2:10PM L 8 ANNULAR SUPER ANN FUEL ALARM ALARM 7-08-16 2:09PM T 4 TANK DIESEL PROBE OUT ALARM 7-08-16 2:07PM T 4 TANK DIESEL MAX PRODUCT ALARM CLEAR 7-08-16 2:06PM T 4 TANK DIESEL MAX PRODUCT ALARM ALARM 7-08-16 2:05PM L 6 ANNULAR REG 2 ANN FUEL ALARM CLEAR 7-08-16 2:04PM I11200 JUL 13, 2016 1:15 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK UNL 2 DELIVERY NEEDED CLEAR 7-08-16 2:39PM T 2 TANK UNL 2 DELIVERY NEEDED ALARM 7-08-16 2:39PM T 2 TANK UNL 2 HIGH PRODUCT ALARM CLEAR 7-08-16 2:38PM T 2 TANK UNL 2 HIGH PRODUCT ALARM ALARM 7-08-16 2:37PM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 7-08-16 2:33PM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 7-08-16 2:33PM T 1 TANK UNL 1 LOW TEMP WARNING CLEAR 7-08-16 2:33PM T 1 TANK UNL 1 HIGH PRODUCT ALARM CLEAR 7-08-16 2:32PM T 1 TANK UNL 1 LOW TEMP WARNING ALARM 7-08-16 2:32PM T 1 TANK UNL 1 HIGH PRODUCT ALARM ALARM 7-08-16 2:32PM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 7-08-16 2:32PM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 7-08-16 2:30PM T 3 TANK PNL LOW TEMP WARNING CLEAR 7-08-16 2:14PM T 3 TANK PNL LOW TEMP WARNING ALARM 7-08-16 2:14PM T 3 TANK PNL HIGH PRODUCT ALARM CLEAR 7-08-16 2:12PM T 3 TANK PNL HIGH PRODUCT ALARM ALARM 7-08-16 2:12PM T 3 TANK PNL DELIVERY NEEDED CLEAR 7-08-16 2:12PM T 3 TANK PNL DELIVERY NEEDED ALARM 7-08-16 2:11PM T 4 TANK DIESEL HIGH PRODUCT ALARM CLEAR 7-08-16 2:06PM T 4 TANK DIESEL HIGH PRODUCT ALARM ALARM 7-08-16 2:05PM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 7-08-16 2:05PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 7-08-16 2:04PM T 2 TANK UNL 2 DELIVERY NEEDED CLEAR 7-08-16 1:00PM T 2 TANK UNL 2 DELIVERY NEEDED ALARM 7-08-16 12:59PM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 6-05-16 3:10PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 6-05-16 6:25AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 5-26-16 3:04PM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 5-26-16 10:01AM OTHER ISD VAPOR LEAK WARN CLEAR 5-25-16 10:01AM SYSTEM PRINTER ERROR CLEAR 5-24-16 6:54PM SYSTEM PAPER OUT CLEAR 5-24-16 6:54PM SYSTEM PRINTER ERROR ALARM 5-24-16 2:31PM SYSTEM PAPER OUT ALARM 5-24-16 2:31PM OTHER ISD VAPOR LEAK WARN ALARM 5-24-16 10:01AM SYSTEM PRINTER ERROR CLEAR 5-23-16 3:35AM SYSTEM PRINTER ERROR ALARM 5-23-16 3:35AM T 2 TANK UNL 2 HIGH WATER WARNING CLEAR 5-18-16 5:38PM T 2 TANK UNL 2 HIGH WATER WARNING ALARM 5-18-16 5:03PM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 5-18-16 9:18AM T 4 TANK DIESEL DELIVERY NEEDED ALARM 5-18-16 9:13AM T 3 TANK PNL DELIVERY NEEDED CLEAR 5-12-16 4:58AM T 3 TANK PNL DELIVERY NEEDED ALARM 5-11-16 11:41PM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 5-10-16 3:25AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 5-08-16 10:00AM T 4 TANK DIESEL DELIVERY NEEDED ALARM 5-08-16 4:55AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 5-06-16 10:01AM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 5-05-16 7:56AM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 5-05-16 5:25AM T 3 TANK PNL DELIVERY NEEDED CLEAR 4-27-16 5:57AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 4-27-16 5:51AM I20600 JUL 13, 2016 1:15 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 TANK ALARM HISTORY TANK 1 UNL 1 OVERFILL ALARM NOV 22, 2015 5:06 AM OCT 25, 2015 10:19 PM OCT 22, 2015 5:41 PM LOW PRODUCT ALARM FEB 23, 2016 7:57 PM SUDDEN LOSS ALARM JUL 8, 2016 1:01 PM MAY 24, 2016 2:31 PM NOV 21, 2015 7:26 PM HIGH PRODUCT ALARM JUL 8, 2016 2:32 PM JUL 16, 2015 9:59 AM JUL 9, 2015 10:38 AM INVALID FUEL LEVEL FEB 23, 2016 7:04 PM PROBE OUT JUL 8, 2016 2:32 PM MAY 18, 2016 4:13 PM JUL 16, 2015 9:59 AM DELIVERY NEEDED JUL 8, 2016 2:33 PM JUL 8, 2016 2:30 PM MAY 5, 2016 5:25 AM MAX PRODUCT ALARM JUL 8, 2016 2:32 PM JUL 8, 2014 12:51 PM LOW TEMP WARNING JUL 8, 2016 2:32 PM JUL 16, 2014 1:03 PM JUL 16, 2014 12:30 PM TANK 2 UNL 2 OVERFILL ALARM NOV 26, 2015 4:47 AM JUN 10, 2015 1:30 PM MAY 22, 2015 2:10 AM SUDDEN LOSS ALARM JUL 8, 2016 1:01 PM MAY 24, 2016 2:31 PM NOV 22, 2015 10:57 PM HIGH PRODUCT ALARM JUL 8, 2016 2:37 PM JUL 16, 2015 9:57 AM JUL 9, 2015 10:39 AM INVALID FUEL LEVEL JUL 16, 2015 9:26 AM JUL 16, 2014 12:31 PM JUL 17, 2013 11:33 AM PROBE OUT JUL 8, 2016 2:38 PM MAY 18, 2016 5:34 PM MAY 18, 2016 3:46 PM HIGH WATER WARNING MAY 18, 2016 5:03 PM DELIVERY NEEDED JUL 8, 2016 2:39 PM JUL 8, 2016 12:59 PM FEB 23, 2016 1:27 PM MAX PRODUCT ALARM JUL 8, 2016 2:37 PM JUL 8, 2014 12:54 PM JUL 17, 2013 12:08 PM LOW TEMP WARNING JUL 16, 2014 1:05 PM TANK 3 PNL OVERFILL ALARM JUL 16, 2015 9:56 AM JUL 9, 2015 10:47 AM JUL 16, 2014 1:05 PM LOW PRODUCT ALARM JUL 8, 2014 12:46 PM HIGH PRODUCT ALARM JUL 8, 2016 2:12 PM JUL 8, 2014 3:34 PM JUL 17, 2013 12:03 PM INVALID FUEL LEVEL JUL 8, 2014 12:46 PM PROBE OUT JUL 8, 2016 2:13 PM JUL 16, 2015 9:56 AM JUL 9, 2015 10:48 AM DELIVERY NEEDED JUL 8, 2016 2:11 PM MAY 11, 2016 11:41 PM APR 26, 2016 6:38 PM MAX PRODUCT ALARM JUL 8, 2016 2:12 PM JUL 8, 2014 3:34 PM JUL 17, 2013 12:03 PM LOW TEMP WARNING JUL 8, 2016 2:14 PM JUL 16, 2014 1:06 PM JUL 17, 2013 12:04 PM TANK 4 DIESEL OVERFILL ALARM JUL 16, 2015 9:54 AM JUL 9, 2015 10:45 AM JUL 16, 2014 1:06 PM LOW PRODUCT ALARM JUL 8, 2014 12:32 PM HIGH PRODUCT ALARM JUL 8, 2016 2:05 PM JUL 8, 2014 1:08 PM JUL 17, 2013 12:06 PM PROBE OUT JUL 8, 2016 2:07 PM MAY 18, 2016 11:25 AM MAY 18, 2016 11:08 AM DELIVERY NEEDED JUL 8, 2016 2:04 PM JUN 5, 2016 6:25 AM MAY 18, 2016 9:13 AM MAX PRODUCT ALARM JUL 8, 2016 2:05 PM JUL 8, 2014 1:08 PM JUL 17, 2013 12:06 PM LOW TEMP WARNING JUL 16, 2015 9:55 AM JUL 16, 2014 1:07 PM JUL 17, 2013 12:07 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUL 13, 2016 1:16 PM I30200 JUL 13, 2016 1:16 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP JUL 8, 2016 2:42 PM SENSOR OUT ALARM JUL 8, 2016 1:29 PM FUEL ALARM JUN 13, 2016 8:46 AM FUEL ALARM 2 UNL 1 ANN JUL 8, 2016 2:42 PM FUEL ALARM JUL 8, 2016 2:31 PM FUEL ALARM JUL 8, 2016 2:23 PM FUEL ALARM 3 DIESEL STP JUL 8, 2016 2:42 PM SENSOR OUT ALARM JUL 8, 2016 1:37 PM FUEL ALARM JUL 16, 2015 9:45 AM FUEL ALARM 4 DIESEL ANN JUL 8, 2016 2:42 PM SENSOR OUT ALARM JUL 8, 2016 1:57 PM FUEL ALARM JUL 16, 2015 9:50 AM FUEL ALARM 5 REG2 STP JUL 11, 2016 11:23 AM FUEL ALARM JUL 8, 2016 2:42 PM SENSOR OUT ALARM JUN 17, 2016 7:38 AM FUEL ALARM 6 REG 2 ANN JUL 8, 2016 2:42 PM SENSOR OUT ALARM JUL 8, 2016 2:01 PM FUEL ALARM JUL 21, 2015 11:11 AM FUEL ALARM 7 SUPER STP JUL 8, 2016 2:42 PM SENSOR OUT ALARM JUL 8, 2016 1:30 PM FUEL ALARM JUL 16, 2015 9:44 AM FUEL ALARM 8 SUPER ANN JUL 8, 2016 2:42 PM SENSOR OUT ALARM JUL 8, 2016 2:09 PM FUEL ALARM JUL 16, 2015 9:50 AM FUEL ALARM 9 DISP 1-2 JUL 8, 2016 2:42 PM SENSOR OUT ALARM JUL 8, 2016 1:06 PM FUEL ALARM JUL 16, 2015 9:46 AM FUEL ALARM 10 DISP 7-8 JUL 8, 2016 2:42 PM SENSOR OUT ALARM JUL 8, 2016 1:15 PM FUEL ALARM FEB 26, 2016 11:57 AM FUEL ALARM 11 DISP 5-6 JUL 8, 2016 2:42 PM SENSOR OUT ALARM JUL 8, 2016 1:11 PM FUEL ALARM JUL 16, 2015 9:46 AM FUEL ALARM 12 DISP 3-4 JUL 8, 2016 2:42 PM SENSOR OUT ALARM JUL 8, 2016 1:02 PM FUEL ALARM JUL 16, 2015 9:48 AM FUEL ALARM I31600 JUL 13, 2016 1:16 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 2 F.M DISP 1-2 3 F.M DISP 3-4 4 F.M DISP 5-6 5 F.M DISP 7-8 8 VP 1-2 I40200 JUL 13, 2016 1:16 PM I40300 JUL 13, 2016 1:16 PM I34200 JUL 13, 2016 1:16 PM I34700 JUL 13, 2016 1:16 PM IV0100 JUL 13, 2016 1:16 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.04 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 16-05-26 10:01:31 A/L RATIO DEGRADATION FP 4 BLEND3 0.80 16-05-24 10:01:33 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 186.01 16-05-07 10:01:09 A/L RATIO DEGRADATION FP 4 BLEND3 0.80 16-05-06 10:01:09 A/L RATIO DEGRADATION FP 4 BLEND3 0.80 16-04-21 10:01:09 A/L RATIO DEGRADATION FP 2 BLEND3 0.80 16-03-02 10:01:26 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.93 16-03-01 10:01:33 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.52 16-02-29 10:01:32 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.79 16-02-22 10:01:15 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.86 16-02-17 10:01:09 A/L RATIO DEGRADATION FP 4 BLEND3 0.78 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 16-01-06 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.95 12-10-02 10:01:09 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 12-10-01 10:01:10 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 11-08-14 10:02:46 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.68 11-08-13 10:02:53 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.68 11-03-21 10:01:52 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 11-03-21 10:01:52 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 11-03-14 10:02:02 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.55 10-11-29 10:01:58 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 10-11-29 10:01:58 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 16-07-09 10:01:09 READINESS ISD:PP EVR:PP ISD & EVR READY 16-07-08 14:44:52 READINESS ISD:PP EVR:NN EVR READINESS PENDING 16-07-08 14:44:52 ISD STARTUP 16-07-08 14:44:26 ISD SHUTDOWN 16-07-06 10:01:09 READINESS ISD:PP EVR:PP ISD & EVR READY 16-07-05 12:29:35 READINESS ISD:PP EVR:NN EVR READINESS PENDING 16-07-05 12:29:35 ISD STARTUP 16-07-05 12:29:29 ISD SHUTDOWN 16-05-26 15:04:26 COLLECTION TEST HH04 GRADE TEST MANUALLY CLEARED 16-04-21 15:01:22 COLLECTION TEST HH02 GRADE TEST MANUALLY CLEARED Jaco 7781 MC alarm history after Responses Received: I10200 JUL 13, 2016 4:27 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39605 39521 2 4 PROBE / G.T. 163800 163645 3 INTERSTITIAL BD 202524 202371 4 INTERSTITIAL BD 201886 201573 5 UNUSED 4904311 4900144 6 UNUSED 4903408 4896066 7 UNUSED 4904752 4895099 8 UNUSED 4902715 4892870 9 STP SENSE BOARD 33209 33180 10 UNUSED 4900671 4899337 11 RELAY BOARD 14993 14986 12 UNUSED 4903905 4896499 13 UNUSED 4902876 4894229 14 UNUSED 4904346 4895028 15 UNUSED 4903695 4894418 16 UNUSED 4903296 4895427 COMM 1 RS232 SERIAL BD 15035 15028 COMM 2 RS232 SERIAL BD 15056 15028 COMM 3 ELEC DISP INT. 101790 101648 COMM 4 UNUSED 4903359 4896562 COMM 5 UNUSED 4901196 4896163 COMM 6 UNUSED 4900839 4893724 I90200 JUL 13, 2016 4:27 PM SOFTWARE REVISION LEVEL VERSION 333.02 SOFTWARE# 346333-100-C CREATED - 12.08.10.11.22 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUL 13, 2016 4:27 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME E 1 OTHER COMMUNICATION ALARM CLEAR 7-13-16 3:05PM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM CLEAR 7-13-16 3:00PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 7-13-16 3:00PM L 7 STP SUMP SUPER STP SENSOR OUT ALARM CLEAR 7-13-16 3:00PM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 7-13-16 3:00PM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM CLEAR 7-13-16 3:00PM L 6 ANNULAR REG 2 ANN SENSOR OUT ALARM CLEAR 7-13-16 3:00PM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 7-13-16 3:00PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 7-13-16 3:00PM L 5 STP SUMP REG2 STP SENSOR OUT ALARM CLEAR 7-13-16 3:00PM L 2 ANNULAR UNL 1 ANN FUEL ALARM CLEAR 7-13-16 3:00PM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 7-13-16 3:00PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 7-13-16 3:00PM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM ALARM 7-13-16 2:59PM L 7 STP SUMP SUPER STP SENSOR OUT ALARM ALARM 7-13-16 2:59PM L 6 ANNULAR REG 2 ANN SENSOR OUT ALARM ALARM 7-13-16 2:59PM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM ALARM 7-13-16 2:59PM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 7-13-16 2:59PM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 7-13-16 2:59PM L 2 ANNULAR UNL 1 ANN FUEL ALARM ALARM 7-13-16 2:59PM L 5 STP SUMP REG2 STP SENSOR OUT ALARM ALARM 7-13-16 2:59PM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 7-13-16 2:58PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 7-13-16 2:58PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 7-13-16 2:58PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM ALARM 7-13-16 2:58PM T 2 TANK UNL 2 MAX PRODUCT ALARM CLEAR 7-13-16 2:47PM T 2 TANK UNL 2 MAX PRODUCT ALARM ALARM 7-13-16 2:47PM T 2 TANK UNL 2 MAX PRODUCT ALARM CLEAR 7-13-16 2:40PM T 2 TANK UNL 2 MAX PRODUCT ALARM ALARM 7-13-16 2:40PM T 1 TANK UNL 1 MAX PRODUCT ALARM CLEAR 7-13-16 2:38PM T 1 TANK UNL 1 MAX PRODUCT ALARM ALARM 7-13-16 2:37PM T 3 TANK PNL PROBE OUT CLEAR 7-13-16 2:29PM T 3 TANK PNL OVERFILL ALARM CLEAR 7-13-16 2:28PM T 3 TANK PNL PROBE OUT ALARM 7-13-16 2:28PM T 3 TANK PNL OVERFILL ALARM ALARM 7-13-16 2:28PM T 3 TANK PNL PROBE OUT CLEAR 7-13-16 2:27PM T 3 TANK PNL PROBE OUT ALARM 7-13-16 2:27PM T 4 TANK DIESEL PROBE OUT CLEAR 7-13-16 2:26PM T 4 TANK DIESEL PROBE OUT ALARM 7-13-16 2:25PM T 4 TANK DIESEL PROBE OUT CLEAR 7-13-16 2:25PM T 4 TANK DIESEL PROBE OUT ALARM 7-13-16 2:24PM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 7-13-16 2:23PM L 8 ANNULAR SUPER ANN FUEL ALARM CLEAR 7-13-16 2:23PM L 6 ANNULAR REG 2 ANN FUEL ALARM CLEAR 7-13-16 2:22PM L 2 ANNULAR UNL 1 ANN FUEL ALARM CLEAR 7-13-16 2:21PM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 7-13-16 2:19PM L 8 ANNULAR SUPER ANN FUEL ALARM ALARM 7-13-16 2:19PM L 6 ANNULAR REG 2 ANN FUEL ALARM ALARM 7-13-16 2:19PM L 2 ANNULAR UNL 1 ANN FUEL ALARM ALARM 7-13-16 2:18PM L 3 STP SUMP DIESEL STP FUEL ALARM CLEAR 7-13-16 2:16PM I11200 JUL 13, 2016 4:27 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK UNL 2 HIGH PRODUCT ALARM CLEAR 7-13-16 2:47PM T 2 TANK UNL 2 HIGH PRODUCT ALARM ALARM 7-13-16 2:47PM T 2 TANK UNL 2 HIGH PRODUCT ALARM CLEAR 7-13-16 2:40PM T 2 TANK UNL 2 HIGH PRODUCT ALARM ALARM 7-13-16 2:40PM T 1 TANK UNL 1 HIGH PRODUCT ALARM CLEAR 7-13-16 2:38PM T 1 TANK UNL 1 HIGH PRODUCT ALARM ALARM 7-13-16 2:37PM T 3 TANK PNL HIGH PRODUCT ALARM CLEAR 7-13-16 2:28PM T 3 TANK PNL HIGH PRODUCT ALARM ALARM 7-13-16 2:28PM T 3 TANK PNL DELIVERY NEEDED CLEAR 7-13-16 2:28PM T 3 TANK PNL DELIVERY NEEDED ALARM 7-13-16 2:26PM T 4 TANK DIESEL LOW TEMP WARNING CLEAR 7-13-16 2:26PM T 4 TANK DIESEL HIGH PRODUCT ALARM CLEAR 7-13-16 2:25PM T 4 TANK DIESEL LOW TEMP WARNING ALARM 7-13-16 2:25PM T 4 TANK DIESEL HIGH PRODUCT ALARM ALARM 7-13-16 2:25PM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 7-13-16 2:25PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 7-13-16 2:24PM T 2 TANK UNL 2 DELIVERY NEEDED CLEAR 7-08-16 2:39PM T 2 TANK UNL 2 DELIVERY NEEDED ALARM 7-08-16 2:39PM T 2 TANK UNL 2 HIGH PRODUCT ALARM CLEAR 7-08-16 2:38PM T 2 TANK UNL 2 HIGH PRODUCT ALARM ALARM 7-08-16 2:37PM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 7-08-16 2:33PM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 7-08-16 2:33PM T 1 TANK UNL 1 LOW TEMP WARNING CLEAR 7-08-16 2:33PM T 1 TANK UNL 1 HIGH PRODUCT ALARM CLEAR 7-08-16 2:32PM T 1 TANK UNL 1 LOW TEMP WARNING ALARM 7-08-16 2:32PM T 1 TANK UNL 1 HIGH PRODUCT ALARM ALARM 7-08-16 2:32PM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 7-08-16 2:32PM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 7-08-16 2:30PM T 3 TANK PNL LOW TEMP WARNING CLEAR 7-08-16 2:14PM T 3 TANK PNL LOW TEMP WARNING ALARM 7-08-16 2:14PM T 3 TANK PNL HIGH PRODUCT ALARM CLEAR 7-08-16 2:12PM T 3 TANK PNL HIGH PRODUCT ALARM ALARM 7-08-16 2:12PM T 3 TANK PNL DELIVERY NEEDED CLEAR 7-08-16 2:12PM T 3 TANK PNL DELIVERY NEEDED ALARM 7-08-16 2:11PM T 4 TANK DIESEL HIGH PRODUCT ALARM CLEAR 7-08-16 2:06PM T 4 TANK DIESEL HIGH PRODUCT ALARM ALARM 7-08-16 2:05PM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 7-08-16 2:05PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 7-08-16 2:04PM T 2 TANK UNL 2 DELIVERY NEEDED CLEAR 7-08-16 1:00PM T 2 TANK UNL 2 DELIVERY NEEDED ALARM 7-08-16 12:59PM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 6-05-16 3:10PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 6-05-16 6:25AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 5-26-16 3:04PM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 5-26-16 10:01AM OTHER ISD VAPOR LEAK WARN CLEAR 5-25-16 10:01AM SYSTEM PRINTER ERROR CLEAR 5-24-16 6:54PM SYSTEM PAPER OUT CLEAR 5-24-16 6:54PM SYSTEM PRINTER ERROR ALARM 5-24-16 2:31PM SYSTEM PAPER OUT ALARM 5-24-16 2:31PM OTHER ISD VAPOR LEAK WARN ALARM 5-24-16 10:01AM I20600 JUL 13, 2016 4:27 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 TANK ALARM HISTORY TANK 1 UNL 1 OVERFILL ALARM NOV 22, 2015 5:06 AM OCT 25, 2015 10:19 PM OCT 22, 2015 5:41 PM LOW PRODUCT ALARM FEB 23, 2016 7:57 PM SUDDEN LOSS ALARM JUL 8, 2016 1:01 PM MAY 24, 2016 2:31 PM NOV 21, 2015 7:26 PM HIGH PRODUCT ALARM JUL 13, 2016 2:37 PM JUL 8, 2016 2:32 PM JUL 16, 2015 9:59 AM INVALID FUEL LEVEL FEB 23, 2016 7:04 PM PROBE OUT JUL 8, 2016 2:32 PM MAY 18, 2016 4:13 PM JUL 16, 2015 9:59 AM DELIVERY NEEDED JUL 8, 2016 2:33 PM JUL 8, 2016 2:30 PM MAY 5, 2016 5:25 AM MAX PRODUCT ALARM JUL 13, 2016 2:37 PM JUL 8, 2016 2:32 PM JUL 8, 2014 12:51 PM LOW TEMP WARNING JUL 8, 2016 2:32 PM JUL 16, 2014 1:03 PM JUL 16, 2014 12:30 PM TANK 2 UNL 2 OVERFILL ALARM NOV 26, 2015 4:47 AM JUN 10, 2015 1:30 PM MAY 22, 2015 2:10 AM SUDDEN LOSS ALARM JUL 8, 2016 1:01 PM MAY 24, 2016 2:31 PM NOV 22, 2015 10:57 PM HIGH PRODUCT ALARM JUL 13, 2016 2:47 PM JUL 13, 2016 2:40 PM JUL 8, 2016 2:37 PM INVALID FUEL LEVEL JUL 16, 2015 9:26 AM JUL 16, 2014 12:31 PM JUL 17, 2013 11:33 AM PROBE OUT JUL 8, 2016 2:38 PM MAY 18, 2016 5:34 PM MAY 18, 2016 3:46 PM HIGH WATER WARNING MAY 18, 2016 5:03 PM DELIVERY NEEDED JUL 8, 2016 2:39 PM JUL 8, 2016 12:59 PM FEB 23, 2016 1:27 PM MAX PRODUCT ALARM JUL 13, 2016 2:47 PM JUL 13, 2016 2:40 PM JUL 8, 2016 2:37 PM LOW TEMP WARNING JUL 16, 2014 1:05 PM TANK 3 PNL OVERFILL ALARM JUL 13, 2016 2:28 PM JUL 16, 2015 9:56 AM JUL 9, 2015 10:47 AM LOW PRODUCT ALARM JUL 8, 2014 12:46 PM HIGH PRODUCT ALARM JUL 13, 2016 2:28 PM JUL 8, 2016 2:12 PM JUL 8, 2014 3:34 PM INVALID FUEL LEVEL JUL 8, 2014 12:46 PM PROBE OUT JUL 13, 2016 2:28 PM JUL 13, 2016 2:27 PM JUL 8, 2016 2:13 PM DELIVERY NEEDED JUL 13, 2016 2:26 PM JUL 8, 2016 2:11 PM MAY 11, 2016 11:41 PM MAX PRODUCT ALARM JUL 8, 2016 2:12 PM JUL 8, 2014 3:34 PM JUL 17, 2013 12:03 PM LOW TEMP WARNING JUL 8, 2016 2:14 PM JUL 16, 2014 1:06 PM JUL 17, 2013 12:04 PM TANK 4 DIESEL OVERFILL ALARM JUL 16, 2015 9:54 AM JUL 9, 2015 10:45 AM JUL 16, 2014 1:06 PM LOW PRODUCT ALARM JUL 8, 2014 12:32 PM HIGH PRODUCT ALARM JUL 13, 2016 2:25 PM JUL 8, 2016 2:05 PM JUL 8, 2014 1:08 PM PROBE OUT JUL 13, 2016 2:25 PM JUL 13, 2016 2:24 PM JUL 8, 2016 2:07 PM DELIVERY NEEDED JUL 13, 2016 2:24 PM JUL 8, 2016 2:04 PM JUN 5, 2016 6:25 AM MAX PRODUCT ALARM JUL 8, 2016 2:05 PM JUL 8, 2014 1:08 PM JUL 17, 2013 12:06 PM LOW TEMP WARNING JUL 13, 2016 2:25 PM JUL 16, 2015 9:55 AM JUL 16, 2014 1:07 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUL 13, 2016 4:27 PM I30200 JUL 13, 2016 4:27 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP JUL 13, 2016 2:58 PM SENSOR OUT ALARM JUL 13, 2016 2:09 PM FUEL ALARM JUL 8, 2016 2:42 PM SENSOR OUT ALARM 2 UNL 1 ANN JUL 13, 2016 2:59 PM FUEL ALARM JUL 13, 2016 2:18 PM FUEL ALARM JUL 8, 2016 2:42 PM FUEL ALARM 3 DIESEL STP JUL 13, 2016 2:59 PM SENSOR OUT ALARM JUL 13, 2016 2:16 PM FUEL ALARM JUL 13, 2016 2:16 PM FUEL ALARM 4 DIESEL ANN JUL 13, 2016 2:59 PM SENSOR OUT ALARM JUL 13, 2016 2:19 PM FUEL ALARM JUL 8, 2016 2:42 PM SENSOR OUT ALARM 5 REG2 STP JUL 13, 2016 2:59 PM SENSOR OUT ALARM JUL 13, 2016 2:13 PM FUEL ALARM JUL 11, 2016 11:23 AM FUEL ALARM 6 REG 2 ANN JUL 13, 2016 2:59 PM SENSOR OUT ALARM JUL 13, 2016 2:19 PM FUEL ALARM JUL 8, 2016 2:42 PM SENSOR OUT ALARM 7 SUPER STP JUL 13, 2016 2:59 PM SENSOR OUT ALARM JUL 13, 2016 2:15 PM FUEL ALARM JUL 8, 2016 2:42 PM SENSOR OUT ALARM 8 SUPER ANN JUL 13, 2016 2:59 PM SENSOR OUT ALARM JUL 13, 2016 2:19 PM FUEL ALARM JUL 8, 2016 2:42 PM SENSOR OUT ALARM 9 DISP 1-2 JUL 13, 2016 2:58 PM SENSOR OUT ALARM JUL 13, 2016 1:53 PM FUEL ALARM JUL 8, 2016 2:42 PM SENSOR OUT ALARM 10 DISP 7-8 JUL 13, 2016 2:59 PM SENSOR OUT ALARM JUL 13, 2016 2:05 PM FUEL ALARM JUL 8, 2016 2:42 PM SENSOR OUT ALARM 11 DISP 5-6 JUL 13, 2016 2:58 PM SENSOR OUT ALARM JUL 13, 2016 1:56 PM FUEL ALARM JUL 8, 2016 2:42 PM SENSOR OUT ALARM 12 DISP 3-4 JUL 13, 2016 2:58 PM SENSOR OUT ALARM JUL 13, 2016 1:58 PM FUEL ALARM JUL 8, 2016 2:42 PM SENSOR OUT ALARM I31600 JUL 13, 2016 4:27 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 2 F.M DISP 1-2 3 F.M DISP 3-4 4 F.M DISP 5-6 5 F.M DISP 7-8 8 VP 1-2 I40200 JUL 13, 2016 4:27 PM I40300 JUL 13, 2016 4:27 PM I34200 JUL 13, 2016 4:27 PM I34700 JUL 13, 2016 4:27 PM IV0100 JUL 13, 2016 4:27 PM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.04 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 16-05-26 10:01:31 A/L RATIO DEGRADATION FP 4 BLEND3 0.80 16-05-24 10:01:33 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 186.01 16-05-07 10:01:09 A/L RATIO DEGRADATION FP 4 BLEND3 0.80 16-05-06 10:01:09 A/L RATIO DEGRADATION FP 4 BLEND3 0.80 16-04-21 10:01:09 A/L RATIO DEGRADATION FP 2 BLEND3 0.80 16-03-02 10:01:26 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.93 16-03-01 10:01:33 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.52 16-02-29 10:01:32 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.79 16-02-22 10:01:15 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.86 16-02-17 10:01:09 A/L RATIO DEGRADATION FP 4 BLEND3 0.78 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 16-01-06 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.95 12-10-02 10:01:09 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 12-10-01 10:01:10 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 11-08-14 10:02:46 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.68 11-08-13 10:02:53 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.68 11-03-21 10:01:52 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 11-03-21 10:01:52 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 11-03-14 10:02:02 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.55 10-11-29 10:01:58 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 10-11-29 10:01:58 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 16-07-13 14:55:11 READINESS ISD:PP EVR:NN EVR READINESS PENDING 16-07-13 14:55:11 ISD STARTUP 16-07-13 14:53:53 ISD SHUTDOWN 16-07-09 10:01:09 READINESS ISD:PP EVR:PP ISD & EVR READY 16-07-08 14:44:52 READINESS ISD:PP EVR:NN EVR READINESS PENDING 16-07-08 14:44:52 ISD STARTUP 16-07-08 14:44:26 ISD SHUTDOWN 16-07-06 10:01:09 READINESS ISD:PP EVR:PP ISD & EVR READY 16-07-05 12:29:35 READINESS ISD:PP EVR:NN EVR READINESS PENDING 16-07-05 12:29:35 ISD STARTUP SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator forsubmittal to the local regulatory agency. 1.FACILITY INFORMATION Facility Name:Date of Testing: Facility Address: Facility Contact:Phone: Date Local Agency Was Notified of Testing : Name of Local Agency Inspector (if present during testing): 2.TESTING CONTRACTOR INFORMATION Company Name:Confidence UST Services, Inc. Technician Conducting Test: Credentials1:CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s):CSLB#804904 ICC# 3.SPILL BUCKET TESTING INFORMATION Test Method Used:Hydrostatic Vacuum Other Test Equipment Used:Lake TestEquipment Resolution:0.0625” Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1234 Bucket Installation Type: Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test: Test Start Time (TI): Initial Reading (RI): Test End Time (TF): Final Reading (RF): Test Duration (TF – TI): Change in Reading (RF -RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Comments –(include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician’s Signature:________________________________________________ Date:_________ 1 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. #7781/Fastrip#22(South)07/13/2016 4013SouthHStreet Bakersfield,CA93304 OmeroGarcia(661)393-7000 06/14/2016 Kris Karns AustinSterling 8339953-UT Regular1 12.00" 13.00" 5min. 1:30 pm 8.00" 2:30 pm 8.00" 1hour 0.00" 0.0625" Regular2 12.00" 13.00" 5min. 1:30 pm 9.00" 2:30 pm 9.00" 1hour 0.00" 0.0625"0.0625" Super 12.00" 13.00" 5min. 1:30 pm 8.50" 2:30 pm 8.50" 1hour 0.00" Diesel 12.00" 15.00" 5min. 1:30 pm 9.75" 2:30 pm 9.75" 1hour 0.00" 0.0625" 07/13/2016