Loading...
HomeMy WebLinkAboutFMC 2015 2/21/07 1 Appendix VI (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.waterboards.ca.gov.) MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of California Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A. General Information Facility Name: _____ California Mini Mart____ ___ _______________________________________ Bldg. No.:___________________ Site Address: __1129 Union Ave. ___________________ _____ City: _Bakersfield ____________ Zip: ____________________ Facility Contact Person: ___________________________________________ Contact Phone No.: (_______)__________________________ Make/Model of Monitoring System: Veeder-Root TLS-350________________________ Date of Testing/Servicing: _1_/28_/ 2015______ B. Inventory of Equipment Tested/Certified Check the appropriate boxes to indicate specific equipment inspected/serviced: Tank ID: _ 87 UL Siphon__ _________________________ X In-Tank Gauging Probe. Model: __Mag.______________ X Annular Space or Vault Sensor. Model: 794380-409 __ __ _ X Piping Sump / Trench Sensor(s). Model: 794380-208 __ __ _ X Fill Sump Sensor(s). Model: 794380-208 __ __ _ Mechanical Line Leak Detector. Model: ____________________ Electronic Line Leak Detector. Model: ____________________ Tank Overfill / High-Level Sensor. Model: ____________________ Other (specify equipment type and model in Section E on Page 2). Tank ID: _ 91 UL_ __________________________ X In-Tank Gauging Probe. Model: __Mag.______________ X Annular Space or Vault Sensor. Model: 794380-409 __ __ _ X Piping Sump / Trench Sensor(s). Model: 794380-208 __ __ _ X Fill Sump Sensor(s). Model: 794380-208 __ __ _ Mechanical Line Leak Detector. Model: ____________________ X Electronic Line Leak Detector. Model: _PLLD_______ _______ Tank Overfill / High-Level Sensor. Model: ____________________ Other (specify equipment type and model in Section E on Page 2). Tank ID: _ 87 UL Master ___________________________ X In-Tank Gauging Probe. Model: __Mag.______________ X Annular Space or Vault Sensor. Model: 794380-409 __ __ _ X Piping Sump / Trench Sensor(s). Model: 794380-208 __ __ _ X Fill Sump Sensor(s). Model: 794380-208 __ __ _ Mechanical Line Leak Detector. Model: ____________________ X Electronic Line Leak Detector. Model: _PLLD_______ _______ Tank Overfill / High-Level Sensor. Model: ____________________ Other (specify equipment type and model in Section E on Page 2). Tank ID: _ Diesel __ ____________________________ X In-Tank Gauging Probe. Model: __Mag.______________ X Annular Space or Vault Sensor. Model: 794380-409 __ __ _ X Piping Sump / Trench Sensor(s). Model: 794380-208 __ __ _ X Fill Sump Sensor(s). Model: 794380-208 __ __ _ Mechanical Line Leak Detector. Model: ____________________ X Electronic Line Leak Detector. Model: _PLLD_______ _______ Tank Overfill / High-Level Sensor. Model: ____________________ Other (specify equipment type and model in Section E on Page 2). Dispenser ID: _1-2 __________________________________ X Dispenser Containment Sensor(s). Model: 794380-208 __ __ _ X Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: _7-8 __________________________________ X Dispenser Containment Sensor(s). Model: 794380-208 __ __ _ X Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: _3-4 __________________________________ X Dispenser Containment Sensor(s). Model: 794380-208 __ __ _ X Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: _ ________________________________ Dispenser Containment Sensor(s). Model: __ __ _ Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: _5-6 __________________________________ X Dispenser Containment Sensor(s). Model: 794380-208 __ __ _ X Shear Valve(s). Dispenser ID: _ ________________________________ Dispenser Containment Sensor(s). Model: __ __ _ Shear Valve(s). Dispenser Containment Float(s) and Chain(s). *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers’ guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): X System set-up X Alarm history report Technician Name (print): _Bruce W. Hinsley___________________ Signature: __________________________________________________ Certification No.: _A25212 _____________________________ License. No.: _971259 C61/D40______________________________ Testing Company Name: _Advanced Compliance_______________________ Phone No.:(661) 706-4321______________________ Testing Company Address: _3704 Littlefalls Ct. Bakersfield, Ca. 93312______________________ Date of Testing/Servicing: _1_/_28_/_2015________ Monitoring System Certification Page 1 of 4 12/07 2/21/07 2 D. Results of Testing/Servicing Software Version Installed: _327.04______________________________ Complete the following checklist: X Yes No* Is the audible alarm operational? X Yes No* Is the visual alarm operational? X Yes No* Were all sensors visually inspected, functionally tested, and confirmed operational? X Yes No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* X N/A If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? X Yes No* N/A For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) X Sump/Trench Sensors; X Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection? X Yes No* X N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? ________% Yes* X No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes* X No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) yes, describe causes in Section E, below. X Yes No* Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable X Yes No* Is all monitoring equipment operational per manufacturer’s specifications? * In Section E below, describe how and when these deficiencies were or will be corrected. E. Comments: ___________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ _________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ _________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ Monitoring System Certification Page 2 of 4 12/07 2/21/07 3 F. In-Tank Gauging / SIR Equipment: X Check this box if tank gauging is used only for inventory control. Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: Yes No* Has all input wiring been inspected for proper entry and termination, including testing for ground faults? Yes No* Were all tank gauging probes visually inspected for damage and residue buildup? Yes No* Was accuracy of system product level readings tested? Yes No* Was accuracy of system water level readings tested? Yes No* Were all probes reinstalled properly? Yes No* Were all items on the equipment manufacturer’s maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): Check this box if LLDs are not installed. Complete the following checklist: X Yes No* N/A For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? (Check all that apply) Simulated leak rate: X X Yes No* Were all LLDs confirmed operational and accurate within regulatory requirements? X Yes No* Was the testing apparatus properly calibrated? Yes No* X N/A For mechanical LLDs, does the LLD restrict product flow if it detects a leak? X Yes No* N/A For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? X Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? X Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? X Yes No* N/A For electronic LLDs, have all accessible wiring connections been visually inspected? X Yes No* Were all items on the equipment manufacturer’s maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. H. Comments: ___________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ Monitoring System Certification Page 3 of 4 12/07 Monitoring System Certification UST Monitoring Site Plan Site Address: ________________________________________________________________________________________________ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date map was drawn: ____/____/____. Instructions If you already have a diagram that shows all required information, you may include it, rather than this page, with your Monitoring System Certification. On your site plan, show the general layout of tanks and piping. Clearly identify locations of the following equipment, if installed: monitoring system control panels; sensors monitoring tank annular spaces, sumps, dispenser pans, spill containers, or other secondary containment areas; mechanical or electronic line leak detectors; and in-tank liquid level probes (if used for leak detection). In the space provided, note the date this Site Plan was prepared. Page _____ of _____05/00 SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: California Mini Mart Date of Testing: 1/28/2015 Facility Address: 1129 Union Ave. Bakersfield, Ca. Facility Contact: Phone: Date Local Agency Was Notified of Testing : Name of Local Agency Inspector (if present during testing): 2. TESTING CONTRACTOR INFORMATION Company Name: Advanced Compliance Technician Conducting Test: Bruce W. Hinsley Credentials1: X CSLB Contractor  ICC Service Tech.  SWRCB Tank Tester  Other (Specify) __________________ License Number(s): 971259 3. SPILL BUCKET TESTING INFORMATION Test Method Used: X Hydrostatic  Vacuum  Other (Specify)____________________________ Test Equipment Used: Visual Equipment Resolution: Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1 87 UL Siphon 2 87 UL Master 3 91 UL 4 Diesel Bucket Installation Type: Direct Bury X Contained in Sump Direct Bury X Contained in Sump Direct Bury X Contained in Sump Direct Bury X Contained in Sump Bucket Diameter: 12” 12” 12” 12” Bucket Depth: 14” 14” 14” 14” Wait time between applying vacuum/water and start of test: 10 min. 10 min. 10 min. 10 min. Test Start Time (TI): 09:30 09:30 09:30 09:30 Initial Reading (RI): 9.50” 9.25” 10.00” 09.50” Test End Time (TF): 10:30 10:30 10:30 10:30 Final Reading (RF): 9.50” 9.25” 10.00” 09.50” Test Duration (TF – TI): 1 Hr. 1 Hr. 1 Hr. 1 Hr. Change in Reading (RF - RI): 0.0” 0.0” 0.0” 0.0” Pass/Fail Threshold or Criteria: 0.25” 0.25” 0.25” 0.25” Test Result: X Pass  Fail X Pass  Fail X Pass  Fail X Pass  Fail Comments – (include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician’s Signature:________________________________________________ Date: 1/28/2015 1 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. Advanced Compliance 3704 Littlefalls Ct. Bakersfield, Ca. 93308 661-706-4321 Fax# 661-589-9329 VAPORLESS MANUFACTURING, INC. LDT-890 Leak Detector Test Record Contractor: Advanced Compliance Customer: California Mini Mart Date: 1/28/2015 Location: 1129 Union Ave. Bakersfield, Ca. Product: 87 UL Technician: Bruce W. Hinsley Submersible Pump Identification Manufacturer: Redjacket Model No.: Serial No.: Notes: Leak Detector Identification Manufacturer: Veeder-Root Description: PLLD Diaphragm-type: Piston-type: Tamper-proof seal installed: Other Style Leak Detector: Notes: Leak Detector in Submersible Pump Test at Dispenser Operating Pump Pressure (psi): 26 (para. 15) Gallons per hour rate: 3.0 (para. 22) Line pressure with pump shut off (psi): 17 (para. 23) Bleed-back Test with pump off (ml): 160 (para. 26) Step-through time to full flow (secs): N/A (para. 30) Leak detector stays in leak search position (Yes/No): N/A (para. 42) Leak Detector Test Pass / Fail Notes: Pass *Complete thermal expansion test before failing leak detector Advanced Compliance 3704 Littlefalls Ct. Bakersfield, Ca. 93308 661-706-4321 Fax# 661-589-9329 VAPORLESS MANUFACTURING, INC. LDT-890 Leak Detector Test Record Contractor: Advanced Compliance Customer: California Mini Mart Date: 1/28/2015 Location: 1129 Union Ave. Bakersfield, Ca. Product: 91 UL Technician: Bruce W. Hinsley Submersible Pump Identification Manufacturer: Redjacket Model No.: Serial No.: Notes: Leak Detector Identification Manufacturer: Veeder-Root Description: PLLD Diaphragm-type: Piston-type: Tamper-proof seal installed: Other Style Leak Detector: Notes: Leak Detector in Submersible Pump Test at Dispenser Operating Pump Pressure (psi): 26 (para. 15) Gallons per hour rate: 3.0 (para. 22) Line pressure with pump shut off (psi): 14 (para. 23) Bleed-back Test with pump off (ml): 110 (para. 26) Step-through time to full flow (secs): N/A (para. 30) Leak detector stays in leak search position (Yes/No): N/A (para. 42) Leak Detector Test Pass / Fail Notes: Pass *Complete thermal expansion test before failing leak detector Advanced Compliance 3704 Littlefalls Ct. Bakersfield, Ca. 93308 661-706-4321 Fax# 661-589-9329 VAPORLESS MANUFACTURING, INC. LDT-890 Leak Detector Test Record Contractor: Advanced Compliance Customer: California Mini Mart Date: 1/28/2015 Location: 1129 Union Ave. Bakersfield, Ca. Product: Diesel Technician: Bruce W. Hinsley Submersible Pump Identification Manufacturer: Redjacket Model No.: Serial No.: Notes: Leak Detector Identification Manufacturer: Veeder-Root Description: PLLD Diaphragm-type: Piston-type: Tamper-proof seal installed: Other Style Leak Detector: Notes: Leak Detector in Submersible Pump Test at Dispenser Operating Pump Pressure (psi): 27 (para. 15) Gallons per hour rate: 3.0 (para. 22) Line pressure with pump shut off (psi): 17 (para. 23) Bleed-back Test with pump off (ml): 95 (para. 26) Step-through time to full flow (secs): N/A (para. 30) Leak detector stays in leak search position (Yes/No): N/A (para. 42) Leak Detector Test Pass / Fail Notes: Pass *Complete thermal expansion test before failing leak detector California Mini Mart Monitor Report Responses Received: 200 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD JAN 28, 2015 12:13 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 87 SIPHON 3634 35.81 0.0 64.6 6050 2 87 MASTER 3287 33.28 0.0 66.4 6397 3 91 1514 19.13 0.0 68.9 8170 4 DIESEL 1175 16.02 0.9 69.7 8509 I90500 JAN 28, 2015 12:13 PM SOFTWARE REVISION LEVEL VERSION 330.01 SOFTWARE# 346330-100-B CREATED - 10.07.23.17.25 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I50500 JAN 28, 2015 12:13 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 JAN 28, 2015 12:13 PM SHIFT TIME 1 : DISABLED I50202 JAN 28, 2015 12:13 PM SHIFT TIME 2 : DISABLED I50203 JAN 28, 2015 12:13 PM SHIFT TIME 3 : DISABLED I50204 JAN 28, 2015 12:13 PM SHIFT TIME 4 : DISABLED I54600 JAN 28, 2015 12:13 PM TANK PER TST NEEDED WRN: DISABLED I54900 JAN 28, 2015 12:13 PM TANK ANN TST NEEDED WRN: DISABLED I55300 JAN 28, 2015 12:13 PM LINE RE-ENABLE METHOD PASS LINE TEST I55600 JAN 28, 2015 12:13 PM LINE PER TST NEEDED WRN: DISABLED I55900 JAN 28, 2015 12:13 PM LINE ANN TST NEEDED WRN: DISABLED I50D00 JAN 28, 2015 12:14 PM PRINT TC VOLUMES ENABLED I50E00 JAN 28, 2015 12:14 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 JAN 28, 2015 12:14 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 JAN 28, 2015 12:14 PM H-PROTOCOL DATA FORMAT HEIGHT I51A01 JAN 28, 2015 12:14 PM DAYLIGHT SAVING TIME DISABLED I51B00 JAN 28, 2015 12:14 PM I51600 JAN 28, 2015 12:14 PM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 JAN 28, 2015 12:14 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 JAN 28, 2015 12:14 PM TANK CHART SECURITY DISABLED I5BD00 JAN 28, 2015 12:14 PM CUSTOM ALARM LABELS DISABLED I56000 JAN 28, 2015 12:14 PM MASS/DENSITY DISABLED I88101 JAN 28, 2015 12:14 PM PORT SETTINGS: COMM BOARD : 1 (FXMOD) BAUD RATE : 2400 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED DIAL TYPE : TONE ANSWER ON : 1 RING MODEM SETUP STRING : DIAL TONE INTERVAL: 32 I88102 JAN 28, 2015 12:14 PM PORT SETTINGS: COMM BOARD : 2 (EDIM ) RS-232 SECURITY CODE : DISABLED I88103 JAN 28, 2015 12:14 PM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88104 JAN 28, 2015 12:14 PM I88105 JAN 28, 2015 12:14 PM I88106 JAN 28, 2015 12:14 PM I52000 JAN 28, 2015 12:14 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE OCT 7, 2013 DISABLED 2 ON DATE OCT 7, 2013 DISABLED 3 ON DATE OCT 7, 2013 DISABLED 4 ON DATE OCT 7, 2013 DISABLED 5 ON DATE OCT 7, 2013 DISABLED 6 ON DATE OCT 7, 2013 DISABLED 7 ON DATE OCT 7, 2013 DISABLED 8 ON DATE OCT 7, 2013 DISABLED I60100 JAN 28, 2015 12:14 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 87 SIPHON ON 2 87 MASTER ON 3 91 ON 4 DIESEL ON I60200 JAN 28, 2015 12:14 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 87 SIPHON 2 87 MASTER 3 91 4 DIESEL I60300 JAN 28, 2015 12:14 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 87 SIPHON 1 2 87 MASTER 1 3 91 2 4 DIESEL 3 I60900 JAN 28, 2015 12:14 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 87 SIPHON 0.000700 2 87 MASTER 0.000700 3 91 0.000700 4 DIESEL 0.000450 I60700 JAN 28, 2015 12:14 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 87 SIPHON 89.75 2 87 MASTER 89.75 3 91 89.75 4 DIESEL 89.75 I60A00 JAN 28, 2015 12:14 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 87 SIPHON 4 PTS 9684 2 87 MASTER 4 PTS 9684 3 91 4 PTS 9684 4 DIESEL 4 PTS 9684 I60400 JAN 28, 2015 12:14 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 87 SIPHON 9684 2 87 MASTER 9684 3 91 9684 4 DIESEL 9684 I60500 JAN 28, 2015 12:14 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 87 SIPHON 9684 7891 4904 1898 2 87 MASTER 9684 7891 4904 1898 3 91 9684 7891 4904 1897 4 DIESEL 9684 7891 4904 1898 I60600 JAN 28, 2015 12:14 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 87 SIPHON 9684 0 0 0 0 7891 0 0 0 0 4904 0 0 0 0 1898 0 0 0 0 2 87 MASTER 9684 0 0 0 0 7891 0 0 0 0 4904 0 0 0 0 1898 0 0 0 0 3 91 9684 0 0 0 0 7891 0 0 0 0 4904 0 0 0 0 1897 0 0 0 0 4 DIESEL 9684 0 0 0 0 7891 0 0 0 0 4904 0 0 0 0 1898 0 0 0 0 I61500 JAN 28, 2015 12:14 PM TANK PRODUCT LABEL METER DATA 1 87 SIPHON NO 2 87 MASTER NO 3 91 NO 4 DIESEL NO I62F00 JAN 28, 2015 12:14 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 87 SIPHON 4.0 IN. 2 87 MASTER 4.0 IN. 3 91 4.0 IN. 4 DIESEL 4.0 IN. I62700 JAN 28, 2015 12:14 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 87 SIPHON 1.0 2 87 MASTER 1.0 3 91 1.0 4 DIESEL 1.0 9999FF1B I62400 JAN 28, 2015 12:14 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 87 SIPHON 2.0 2 87 MASTER 2.0 3 91 2.0 4 DIESEL 2.0 I62800 JAN 28, 2015 12:14 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 87 SIPHON 9684 2 87 MASTER 9684 3 91 9684 4 DIESEL 9684 I62300 JAN 28, 2015 12:14 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 87 SIPHON 8715 2 87 MASTER 8715 3 91 8715 4 DIESEL 8715 I62200 JAN 28, 2015 12:14 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 87 SIPHON 9199 2 87 MASTER 9199 3 91 9199 4 DIESEL 9199 I62900 JAN 28, 2015 12:14 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 87 SIPHON 0 2 87 MASTER 968 3 91 968 4 DIESEL 968 I62100 JAN 28, 2015 12:14 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 87 SIPHON 375 2 87 MASTER 375 3 91 375 4 DIESEL 375 I62600 JAN 28, 2015 12:14 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 87 SIPHON 99 2 87 MASTER 99 3 91 99 4 DIESEL 99 I62500 JAN 28, 2015 12:14 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 87 SIPHON 99 2 87 MASTER 99 3 91 99 4 DIESEL 99 I60800 JAN 28, 2015 12:14 PM TANK TILT TANK PRODUCT LABEL INCHES 1 87 SIPHON 0.00 2 87 MASTER 0.00 3 91 0.00 4 DIESEL 0.00 I60B00 JAN 28, 2015 12:14 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 JAN 28, 2015 12:14 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 87 SIPHON 0.00 2 87 MASTER 0.00 3 91 0.00 4 DIESEL 0.00 I61200 JAN 28, 2015 12:14 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 87 SIPHON NONE NONE 2 87 MASTER NONE NONE 3 91 NONE NONE 4 DIESEL NONE NONE I63600 JAN 28, 2015 12:14 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 87 SIPHON 0 2 87 MASTER 0 3 91 0 4 DIESEL 0 I62A00 JAN 28, 2015 12:14 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 87 SIPHON 0 2 87 MASTER 0 3 91 0 4 DIESEL 0 I62C00 JAN 28, 2015 12:14 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 87 SIPHON STANDARD 2 87 MASTER STANDARD 3 91 STANDARD 4 DIESEL STANDARD I62D00 JAN 28, 2015 12:14 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 87 SIPHON GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 87 MASTER GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 91 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 JAN 28, 2015 12:14 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 87 SIPHON OFF OFF 2 87 MASTER OFF OFF 3 91 OFF OFF 4 DIESEL OFF OFF I63000 JAN 28, 2015 12:14 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 87 SIPHON OFF 2 87 MASTER OFF 3 91 OFF 4 DIESEL OFF I63200 JAN 28, 2015 12:14 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 87 SIPHON OFF 2 87 MASTER OFF 3 91 OFF 4 DIESEL OFF I61000 JAN 28, 2015 12:14 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 87 SIPHON 1 2 87 MASTER 1 3 91 1 4 DIESEL 1 I63A00 JAN 28, 2015 12:14 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 87 SIPHON 10.00% 2 87 MASTER 10.00% 3 91 10.00% 4 DIESEL 10.00% I61100 JAN 28, 2015 12:14 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JUL 1, 2009 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 JAN 28, 2015 12:14 PM CSLD PROBABLITY OF DETECTION I61400 JAN 28, 2015 12:14 PM CSLD CLIMATE FACTOR I61600 JAN 28, 2015 12:14 PM TANK PRODUCT LABEL CAL UPDATE 1 87 SIPHON IMMEDIATE 2 87 MASTER IMMEDIATE 3 91 IMMEDIATE 4 DIESEL IMMEDIATE I61A00 JAN 28, 2015 12:14 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 87 SIPHON DISABLED 2 87 MASTER DISABLED 3 91 DISABLED 4 DIESEL DISABLED I61B00 JAN 28, 2015 12:14 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 JAN 28, 2015 12:14 PM CSLD REPORT ONLY I62B00 JAN 28, 2015 12:14 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 87 SIPHON ??? 0, 0 2 87 MASTER ??? 0, 0 3 91 ??? 0, 0 4 DIESEL ??? 0, 0 I63300 JAN 28, 2015 12:14 PM LEAK TEST REPORT FORMAT: NORMAL I63400 JAN 28, 2015 12:14 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 87 SIPHON 0 2 87 MASTER 0 3 91 0 4 DIESEL 0 I63500 JAN 28, 2015 12:14 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 87 SIPHON 1 2 87 MASTER 1 3 91 1 4 DIESEL 1 I63900 JAN 28, 2015 12:14 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 87 SIPHON END FACTOR: NONE 2 87 MASTER END FACTOR: NONE 3 91 END FACTOR: NONE 4 DIESEL END FACTOR: NONE I78000 JAN 28, 2015 12:14 PM PRESSURE LINE LEAK SETUP Q 1:87 TYP:2.0/3.0IN FIBERGLASS 2.0IN DIA LEN: 130 FEET 3.0IN DIA LEN: 0 FEET SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 0 PSI T 2:87 MASTER DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 2:91 TYP:2.0/3.0IN FIBERGLASS 2.0IN DIA LEN: 130 FEET 3.0IN DIA LEN: 0 FEET SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 0 PSI T 3:91 DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 3:DIESEL TYP:2.0/3.0IN FIBERGLASS 2.0IN DIA LEN: 100 FEET 3.0IN DIA LEN: 0 FEET SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 0 PSI T 4:DIESEL DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO I77700 JAN 28, 2015 12:14 PM I77800 JAN 28, 2015 12:14 PM I78C00 JAN 28, 2015 12:14 PM I78300 JAN 28, 2015 12:14 PM I78F00 JAN 28, 2015 12:14 PM PRESSURE LINE LEAK DISPENSE THRESHOLD LINE LOW PRESSURE Q 1:87 0 PSI Q 2:91 0 PSI Q 3:DIESEL 0 PSI I78700 JAN 28, 2015 12:14 PM PRESSURE LLD SETUP REPORT Q 1:87 IN-TANK ALARMS T 1:HIGH WATER ALARM T 2:HIGH WATER ALARM T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL Q 2:91 IN-TANK ALARMS T 3:HIGH WATER ALARM T 3:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP STATUS FAIL ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL Q 3:DIESEL IN-TANK ALARMS T 4:HIGH WATER ALARM T 4:LOW PRODUCT ALARM LIQUID SENSOR ALMS L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM I70200 JAN 28, 2015 12:15 PM LIQUID LABEL DEVICE LABEL 1 87 SIPHON ANNULAR 2 87 SIPHON FILL 3 87 SIPHON SUMP 4 87 MASTER ANNULAR 5 87 MASTER FILL 6 87 MASTER STP 7 91 ANNULAR 8 91 FILL 9 91 STP 10 DIESEL ANNULAR 11 DIESEL FILL 12 DIESEL STP 13 DISP 1 2 14 DISP 3 4 15 DISP 5 6 16 DISP 7 8 17 18 19 20 21 22 23 24 I70300 JAN 28, 2015 12:15 PM LIQUID TYPE SENSOR LOCATION TYPE 1 87 SIPHON ANNULAR TRI-STATE (SINGLE FLOAT) 2 87 SIPHON FILL TRI-STATE (SINGLE FLOAT) 3 87 SIPHON SUMP TRI-STATE (SINGLE FLOAT) 4 87 MASTER ANNULAR TRI-STATE (SINGLE FLOAT) 5 87 MASTER FILL TRI-STATE (SINGLE FLOAT) 6 87 MASTER STP TRI-STATE (SINGLE FLOAT) 7 91 ANNULAR TRI-STATE (SINGLE FLOAT) 8 91 FILL TRI-STATE (SINGLE FLOAT) 9 91 STP TRI-STATE (SINGLE FLOAT) 10 DIESEL ANNULAR TRI-STATE (SINGLE FLOAT) 11 DIESEL FILL TRI-STATE (SINGLE FLOAT) 12 DIESEL STP TRI-STATE (SINGLE FLOAT) 13 DISP 1 2 TRI-STATE (SINGLE FLOAT) 14 DISP 3 4 TRI-STATE (SINGLE FLOAT) 15 DISP 5 6 TRI-STATE (SINGLE FLOAT) 16 DISP 7 8 TRI-STATE (SINGLE FLOAT) 17 TRI-STATE (SINGLE FLOAT) 18 TRI-STATE (SINGLE FLOAT) 19 TRI-STATE (SINGLE FLOAT) 20 TRI-STATE (SINGLE FLOAT) 21 TRI-STATE (SINGLE FLOAT) 22 TRI-STATE (SINGLE FLOAT) 23 TRI-STATE (SINGLE FLOAT) 24 TRI-STATE (SINGLE FLOAT) I70400 JAN 28, 2015 12:15 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 87 SIPHON ANNULAR ANNULAR SPACE 2 87 SIPHON FILL OTHER SENSORS 3 87 SIPHON SUMP PIPING SUMP 4 87 MASTER ANNULAR ANNULAR SPACE 5 87 MASTER FILL OTHER SENSORS 6 87 MASTER STP STP SUMP 7 91 ANNULAR ANNULAR SPACE 8 91 FILL OTHER SENSORS 9 91 STP STP SUMP 10 DIESEL ANNULAR ANNULAR SPACE 11 DIESEL FILL OTHER SENSORS 12 DIESEL STP STP SUMP 13 DISP 1 2 DISPENSER PAN 14 DISP 3 4 DISPENSER PAN 15 DISP 5 6 DISPENSER PAN 16 DISP 7 8 DISPENSER PAN 17 OTHER SENSORS 18 OTHER SENSORS 19 OTHER SENSORS 20 OTHER SENSORS 21 OTHER SENSORS 22 OTHER SENSORS 23 OTHER SENSORS 24 OTHER SENSORS I74200 JAN 28, 2015 12:15 PM I74300 JAN 28, 2015 12:15 PM I74400 JAN 28, 2015 12:15 PM I74700 JAN 28, 2015 12:15 PM I74800 JAN 28, 2015 12:15 PM I74900 JAN 28, 2015 12:15 PM I7BC00 JAN 28, 2015 12:15 PM I80200 JAN 28, 2015 12:15 PM I80300 JAN 28, 2015 12:15 PM I80400 JAN 28, 2015 12:15 PM I80700 JAN 28, 2015 12:15 PM RELAY LABEL DEVICE LABEL 1 2 3 4 I80900 JAN 28, 2015 12:15 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 NORMALLY OPEN 2 NORMALLY OPEN 3 NORMALLY OPEN 4 NORMALLY OPEN I80B00 JAN 28, 2015 12:15 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 NONE 2 NONE 3 NONE 4 NONE I80A00 JAN 28, 2015 12:15 PM RELAY TYPE RELAY DESIGNATION TYPE 1 STANDARD 2 STANDARD 3 STANDARD 4 STANDARD I80C00 JAN 28, 2015 12:15 PM I80800 JAN 28, 2015 12:15 PM RELAY SETUP REPORT R 1: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 2: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 3: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 JAN 28, 2015 12:15 PM EDIM:1 VR:349643-001-B TD:97.10.27.11.25 I79100 JAN 28, 2015 12:15 PM I72300 JAN 28, 2015 12:15 PM 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 PRESSURE SENSOR VAPOR PRESSURE 02 CANNISTER VAPOR VALVE 03 DISP 1-2 AIR FLOW METER 04 DISP 3 4 AIR FLOW METER 05 DISP 5 6 AIR FLOW METER 06 DISP 7 8 AIR FLOW METER 07 UNKNOWN 08 ATMOSPHERIC ATM P SENSOR 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN I72A00 JAN 28, 2015 12:15 PM VACUUM SENSOR VOLUME DEVICE LABEL VOLUME IV4E00 JAN 28, 2015 12:15 PM 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD EVR/ISD SETUP TYPE: BALANCE IV4F00 JAN 28, 2015 12:15 PM 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD NOZZLE A/L RANGE A/L RATIO: 1.00 - 1.20 IV4000 JAN 28, 2015 12:15 PM 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD VAPOR PROCESSOR TYPE VEEDER-ROOT POLISHER IV4700 JAN 28, 2015 12:15 PM 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD ASSESSMENT TIME START TIME: 8:30 AM TIME DELAY MINUTES: 1 IV5200 JAN 28, 2015 12:15 PM 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD ACCEPT HIGH ORVR: YES IV4A00 JAN 28, 2015 12:15 PM 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 01 01 01 BLEND3 02 02 02 01 BLEND3 03 03 03 02 BLEND3 04 04 04 02 BLEND3 05 05 05 03 BLEND3 06 06 06 03 BLEND3 07 07 07 04 BLEND3 08 08 08 04 BLEND3 IV4B00 JAN 28, 2015 12:15 PM 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 09/01 01/01 xx/xx 02 01 02/02 09/02 01/02 xx/xx 03 02 02/03 09/03 01/03 xx/xx 04 02 02/04 09/04 01/04 xx/xx 05 03 09/05 02/05 01/05 xx/xx 06 03 02/06 09/06 01/06 xx/xx 07 04 02/07 09/07 01/07 xx/xx 08 04 02/08 09/08 01/08 xx/xx IV4900 JAN 28, 2015 12:15 PM 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 JAN 28, 2015 12:15 PM ISD VERSION: 01.03 Responses Received: I10200 JAN 28, 2015 12:16 PM 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 INTERSTITIAL BD 201586 201530 2 INTERSTITIAL BD 201375 201340 3 INTERSTITIAL BD 202265 202313 4 4 PROBE / G.T. 163007 163032 5 PLLD SENSOR BD 3894 3895 6 7SMARTSENSOR BD 510167 509576 7 UNUSED 10342602 10356144 8 UNUSED 10333026 10345031 9 PLLD POWER BD 100724 100789 10 RELAY BOARD 15030 15022 11 UNUSED 10337225 10366864 12 UNUSED 10334002 10334963 13 UNUSED 10332020 10356367 14 UNUSED 10317126 10345483 15 UNUSED 10338081 10342744 16 UNUSED 10319266 10351963 COMM 1 FAXMODEM BOARD 40378 40349 COMM 2 ELEC DISP INT. 101298 101277 COMM 3 RS232 SERIAL BD 14984 14976 COMM 4 UNUSED 10338779 10363829 COMM 5 UNUSED 10311335 10332430 COMM 6 UNUSED 10338081 10343497 I90200 JAN 28, 2015 12:16 PM SOFTWARE REVISION LEVEL VERSION 330.01 SOFTWARE# 346330-100-B CREATED - 10.07.23.17.25 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 JAN 28, 2015 12:16 PM 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM CLEAR 1-28-15 11:08AM L12 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 1-28-15 11:08AM L12 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 1-28-15 11:07AM Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM ALARM 1-28-15 11:07AM Q 2 OTHER 91 PLLD SHUTDOWN ALARM CLEAR 1-28-15 10:57AM L 8 OTHER 91 FILL SENSOR OUT ALARM CLEAR 1-28-15 10:57AM Q 1 OTHER 87 PLLD SHUTDOWN ALARM CLEAR 1-28-15 10:57AM L 6 STP SUMP 87 MASTER STP SENSOR OUT ALARM CLEAR 1-28-15 10:57AM Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM CLEAR 1-28-15 10:57AM L11 OTHER DIESEL FILL SENSOR OUT ALARM CLEAR 1-28-15 10:57AM L 9 STP SUMP 91 STP SENSOR OUT ALARM CLEAR 1-28-15 10:57AM L 7 ANNULAR 91 ANNULAR SENSOR OUT ALARM CLEAR 1-28-15 10:57AM L 2 OTHER 87 SIPHON FILL SENSOR OUT ALARM CLEAR 1-28-15 10:57AM L10 ANNULAR DIESEL ANNULAR SENSOR OUT ALARM CLEAR 1-28-15 10:57AM L15 DISP PAN DISP 5 6 SENSOR OUT ALARM CLEAR 1-28-15 10:57AM L 5 OTHER 87 MASTER FILL SENSOR OUT ALARM CLEAR 1-28-15 10:57AM L 4 ANNULAR 87 MASTER ANNULAR SENSOR OUT ALARM CLEAR 1-28-15 10:57AM L16 DISP PAN DISP 7 8 SENSOR OUT ALARM CLEAR 1-28-15 10:57AM L14 DISP PAN DISP 3 4 SENSOR OUT ALARM CLEAR 1-28-15 10:57AM L 1 ANNULAR 87 SIPHON ANNULAR SENSOR OUT ALARM CLEAR 1-28-15 10:57AM L12 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 1-28-15 10:57AM L 3 PIPE 87 SIPHON SUMP SENSOR OUT ALARM CLEAR 1-28-15 10:57AM L13 DISP PAN DISP 1 2 SENSOR OUT ALARM CLEAR 1-28-15 10:57AM L11 OTHER DIESEL FILL SENSOR OUT ALARM ALARM 1-28-15 10:57AM L15 DISP PAN DISP 5 6 SENSOR OUT ALARM ALARM 1-28-15 10:56AM L 8 OTHER 91 FILL SENSOR OUT ALARM ALARM 1-28-15 10:56AM L14 DISP PAN DISP 3 4 SENSOR OUT ALARM ALARM 1-28-15 10:56AM L 6 STP SUMP 87 MASTER STP SENSOR OUT ALARM ALARM 1-28-15 10:56AM L 2 OTHER 87 SIPHON FILL SENSOR OUT ALARM ALARM 1-28-15 10:56AM L12 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 1-28-15 10:56AM L10 ANNULAR DIESEL ANNULAR SENSOR OUT ALARM ALARM 1-28-15 10:56AM L 9 STP SUMP 91 STP SENSOR OUT ALARM ALARM 1-28-15 10:56AM L16 DISP PAN DISP 7 8 SENSOR OUT ALARM ALARM 1-28-15 10:56AM Q 3 OTHER DIESEL PLLD SHUTDOWN ALARM ALARM 1-28-15 10:56AM L 7 ANNULAR 91 ANNULAR SENSOR OUT ALARM ALARM 1-28-15 10:56AM L 5 OTHER 87 MASTER FILL SENSOR OUT ALARM ALARM 1-28-15 10:56AM L 4 ANNULAR 87 MASTER ANNULAR SENSOR OUT ALARM ALARM 1-28-15 10:56AM L13 DISP PAN DISP 1 2 SENSOR OUT ALARM ALARM 1-28-15 10:56AM Q 2 OTHER 91 PLLD SHUTDOWN ALARM ALARM 1-28-15 10:56AM L 3 PIPE 87 SIPHON SUMP SENSOR OUT ALARM ALARM 1-28-15 10:56AM L 1 ANNULAR 87 SIPHON ANNULAR SENSOR OUT ALARM ALARM 1-28-15 10:56AM Q 1 OTHER 87 PLLD SHUTDOWN ALARM ALARM 1-28-15 10:56AM Q 2 OTHER 91 PLLD SHUTDOWN ALARM CLEAR 1-28-15 10:47AM Q 2 OTHER 91 GROSS LINE FAIL CLEAR 1-28-15 10:47AM Q 1 OTHER 87 PLLD SHUTDOWN ALARM CLEAR 1-28-15 10:46AM Q 1 OTHER 87 GROSS LINE FAIL CLEAR 1-28-15 10:46AM Q 2 OTHER 91 PLLD SHUTDOWN ALARM ALARM 1-28-15 10:36AM Q 2 OTHER 91 GROSS LINE FAIL ALARM 1-28-15 10:36AM Q 1 OTHER 87 PLLD SHUTDOWN ALARM ALARM 1-28-15 10:30AM Q 1 OTHER 87 GROSS LINE FAIL ALARM 1-28-15 10:30AM I11200 JAN 28, 2015 12:16 PM 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 1-28-15 11:00AM SYSTEM PAPER OUT CLEAR 1-28-15 11:00AM SYSTEM PRINTER ERROR ALARM 1-28-15 11:00AM SYSTEM PAPER OUT ALARM 1-28-15 11:00AM SYSTEM PRINTER ERROR CLEAR 1-28-15 10:59AM SYSTEM PAPER OUT CLEAR 1-28-15 10:59AM SYSTEM PRINTER ERROR ALARM 1-28-15 10:57AM SYSTEM PAPER OUT ALARM 1-28-15 10:57AM h 3 OTHER FP3: BLEND3 FLOW COLLECT WARN CLEAR 1-27-15 8:30AM h 3 OTHER FP3: BLEND3 FLOW COLLECT WARN ALARM 1-26-15 8:31AM h 3 OTHER FP3: BLEND3 FLOW COLLECT WARN CLEAR 1-23-15 8:30AM h 3 OTHER FP3: BLEND3 FLOW COLLECT WARN ALARM 1-22-15 8:31AM T 2 TANK 87 MASTER DELIVERY NEEDED CLEAR 1-16-15 9:59PM T 2 TANK 87 MASTER INVALID FUEL LEVEL CLEAR 1-16-15 9:58PM T 2 TANK 87 MASTER INVALID FUEL LEVEL ALARM 1-16-15 9:11PM T 2 TANK 87 MASTER DELIVERY NEEDED ALARM 1-16-15 1:42PM T 2 TANK 87 MASTER DELIVERY NEEDED CLEAR 1-14-15 7:29AM T 2 TANK 87 MASTER INVALID FUEL LEVEL CLEAR 1-14-15 7:28AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 1-14-15 7:20AM SYSTEM PRINTER ERROR CLEAR 1-14-15 7:09AM SYSTEM PAPER OUT CLEAR 1-14-15 7:09AM SYSTEM PRINTER ERROR ALARM 1-14-15 7:07AM SYSTEM PAPER OUT ALARM 1-14-15 7:07AM T 2 TANK 87 MASTER INVALID FUEL LEVEL ALARM 1-14-15 3:32AM T 2 TANK 87 MASTER DELIVERY NEEDED ALARM 1-13-15 2:09PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 1-12-15 4:16AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 1-10-15 1:33AM T 4 TANK DIESEL INVALID FUEL LEVEL CLEAR 1-10-15 1:32AM T 4 TANK DIESEL INVALID FUEL LEVEL ALARM 1-08-15 10:26AM T 4 TANK DIESEL DELIVERY NEEDED ALARM 1-04-15 10:56AM h 3 OTHER FP3: BLEND3 FLOW COLLECT WARN CLEAR 12-31-14 8:30AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 12-29-14 7:34AM h 3 OTHER FP3: BLEND3 FLOW COLLECT WARN ALARM 12-28-14 8:32AM h 3 OTHER FP3: BLEND3 FLOW COLLECT WARN CLEAR 12-25-14 8:30AM h 3 OTHER FP3: BLEND3 FLOW COLLECT WARN ALARM 12-24-14 8:31AM T 4 TANK DIESEL DELIVERY NEEDED ALARM 12-23-14 11:49AM SYSTEM PRINTER ERROR CLEAR 12-15-14 7:14AM SYSTEM PAPER OUT CLEAR 12-15-14 7:14AM SYSTEM PRINTER ERROR ALARM 12-15-14 7:11AM SYSTEM PAPER OUT ALARM 12-15-14 7:11AM T 2 TANK 87 MASTER DELIVERY NEEDED CLEAR 12-10-14 2:05PM T 2 TANK 87 MASTER DELIVERY NEEDED ALARM 12-10-14 9:38AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 12-06-14 10:06AM T 4 TANK DIESEL DELIVERY NEEDED ALARM 12-02-14 8:08AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 11-23-14 9:47AM T 4 TANK DIESEL DELIVERY NEEDED ALARM 11-21-14 9:09AM T 2 TANK 87 MASTER DELIVERY NEEDED CLEAR 11-20-14 2:59PM T 2 TANK 87 MASTER DELIVERY NEEDED ALARM 11-20-14 8:04AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 11-16-14 9:15AM T 4 TANK DIESEL DELIVERY NEEDED ALARM 11-10-14 4:05PM I20600 JAN 28, 2015 12:16 PM 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD TANK ALARM HISTORY TANK 1 87 SIPHON TANK 2 87 MASTER INVALID FUEL LEVEL JAN 16, 2015 9:11 PM JAN 14, 2015 3:32 AM DELIVERY NEEDED JAN 16, 2015 1:42 PM JAN 13, 2015 2:09 PM DEC 10, 2014 9:38 AM TANK 3 91 TANK 4 DIESEL LOW PRODUCT ALARM JAN 10, 2015 1:31 AM INVALID FUEL LEVEL JAN 8, 2015 10:26 AM DELIVERY NEEDED JAN 12, 2015 4:16 AM JAN 4, 2015 10:56 AM DEC 23, 2014 11:49 AM I38200 JAN 28, 2015 12:16 PM 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD PRESSURE LINE LEAK ALARM HISTORY REPORT Q 1:87 JAN 28, 2015 10:56 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:30 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:30 AM GROSS LINE FAIL JAN 28, 2015 10:04 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:03 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:02 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:02 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:01 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:01 AM PLLD SHUTDOWN ALARM JAN 28, 2015 9:59 AM PLLD SHUTDOWN ALARM Q 2:91 JAN 28, 2015 10:56 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:36 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:36 AM GROSS LINE FAIL JAN 28, 2015 10:04 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:03 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:02 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:02 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:01 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:01 AM PLLD SHUTDOWN ALARM JAN 28, 2015 9:59 AM PLLD SHUTDOWN ALARM Q 3:DIESEL JAN 28, 2015 11:07 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:56 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:04 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:03 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:02 AM PLLD SHUTDOWN ALARM JAN 28, 2015 10:02 AM PLLD SHUTDOWN ALARM JAN 28, 2015 9:55 AM PLLD SHUTDOWN ALARM JAN 28, 2015 9:55 AM PLLD SHUTDOWN ALARM JAN 28, 2015 9:32 AM PLLD SHUTDOWN ALARM JAN 28, 2015 9:31 AM PLLD SHUTDOWN ALARM I30200 JAN 28, 2015 12:16 PM 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87 SIPHON ANNULAR JAN 28, 2015 10:56 AM SENSOR OUT ALARM JAN 28, 2015 9:30 AM FUEL ALARM JUL 23, 2010 8:03 AM SETUP DATA WARNING 2 87 SIPHON FILL JAN 28, 2015 10:56 AM SENSOR OUT ALARM JAN 28, 2015 9:41 AM SENSOR OUT ALARM JAN 28, 2015 9:34 AM FUEL ALARM 3 87 SIPHON SUMP JAN 28, 2015 10:56 AM SENSOR OUT ALARM JAN 28, 2015 9:58 AM FUEL ALARM NOV 6, 2014 11:56 AM FUEL ALARM 4 87 MASTER ANNULAR JAN 28, 2015 10:56 AM SENSOR OUT ALARM JAN 28, 2015 9:30 AM FUEL ALARM JUL 23, 2010 8:03 AM SETUP DATA WARNING 5 87 MASTER FILL JAN 28, 2015 10:56 AM SENSOR OUT ALARM JAN 28, 2015 9:34 AM FUEL ALARM NOV 6, 2014 12:48 PM FUEL ALARM 6 87 MASTER STP JAN 28, 2015 10:56 AM SENSOR OUT ALARM JAN 28, 2015 9:57 AM SENSOR OUT ALARM JAN 28, 2015 9:57 AM FUEL ALARM 7 91 ANNULAR JAN 28, 2015 10:56 AM SENSOR OUT ALARM JAN 28, 2015 9:29 AM FUEL ALARM JUL 23, 2010 8:03 AM SETUP DATA WARNING 8 91 FILL JAN 28, 2015 10:56 AM SENSOR OUT ALARM JAN 28, 2015 9:42 AM SENSOR OUT ALARM JAN 28, 2015 9:33 AM FUEL ALARM 9 91 STP JAN 28, 2015 10:56 AM SENSOR OUT ALARM JAN 28, 2015 9:56 AM SENSOR OUT ALARM JAN 28, 2015 9:56 AM FUEL ALARM 10 DIESEL ANNULAR JAN 28, 2015 10:56 AM SENSOR OUT ALARM JAN 28, 2015 9:26 AM FUEL ALARM JUL 23, 2010 8:03 AM SETUP DATA WARNING 11 DIESEL FILL JAN 28, 2015 10:57 AM SENSOR OUT ALARM JAN 28, 2015 9:32 AM SENSOR OUT ALARM JAN 28, 2015 9:32 AM FUEL ALARM 12 DIESEL STP JAN 28, 2015 11:07 AM SENSOR OUT ALARM JAN 28, 2015 10:56 AM SENSOR OUT ALARM JAN 28, 2015 9:55 AM SENSOR OUT ALARM 13 DISP 1 2 JAN 28, 2015 10:56 AM SENSOR OUT ALARM JAN 28, 2015 9:59 AM FUEL ALARM NOV 6, 2014 11:30 AM SENSOR OUT ALARM 14 DISP 3 4 JAN 28, 2015 10:56 AM SENSOR OUT ALARM JAN 28, 2015 10:01 AM SENSOR OUT ALARM JAN 28, 2015 10:01 AM FUEL ALARM 15 DISP 5 6 JAN 28, 2015 10:56 AM SENSOR OUT ALARM JAN 28, 2015 10:04 AM SENSOR OUT ALARM JAN 28, 2015 10:03 AM FUEL ALARM 16 DISP 7 8 JAN 28, 2015 10:56 AM SENSOR OUT ALARM JAN 28, 2015 10:02 AM SENSOR OUT ALARM JAN 28, 2015 10:02 AM FUEL ALARM I31600 JAN 28, 2015 12:16 PM 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PRESSURE SENSOR 2 CANNISTER 3 DISP 1-2 4 DISP 3 4 5 DISP 5 6 6 DISP 7 8 8 ATMOSPHERIC I40200 JAN 28, 2015 12:16 PM I40300 JAN 28, 2015 12:16 PM I34200 JAN 28, 2015 12:16 PM I34700 JAN 28, 2015 12:16 PM IV0100 JAN 28, 2015 12:16 PM 1129 UNION AVE 661-395-0868 93307 BAKERSFIELD ISD ALARM STATUS REPORT EVR TYPE: BALANCE ISD TYPE: 01.03 VAPOR PROCESSOR TYPE: VEEDER-ROOT POLISHER OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% VAPOR PROCESSOR :PASS WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 15-01-26 08:31:44 FLOW PERFORMANCE HOSE BLOCKAGE FP 3 BLEND3 BLKD 15-01-22 08:31:09 FLOW PERFORMANCE HOSE BLOCKAGE FP 3 BLEND3 BLKD 14-12-30 08:33:32 FLOW PERFORMANCE HOSE BLOCKAGE FP 3 BLEND3 0.57 14-12-28 08:32:12 FLOW PERFORMANCE HOSE BLOCKAGE FP 3 BLEND3 BLKD 14-12-24 08:31:24 FLOW PERFORMANCE HOSE BLOCKAGE FP 3 BLEND3 0.52 14-10-04 08:33:05 SENSOR OUT SELFTEST E 1 14-08-09 08:33:33 FLOW PERFORMANCE HOSE BLOCKAGE FP 6 BLEND3 0.59 14-07-02 08:31:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 5.00 14-07-01 08:31:09 VAPOR PROCESSOR OVER PRESSURE DAILY 90% 5.00 14-07-01 08:31:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.65 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 15-01-27 08:31:24 FLOW PERFORMANCE HOSE BLOCKAGE FP 3 BLEND3 14-07-03 08:31:09 VAPOR PROCESSOR OVER PRESSURE DAILY 90% 5.00 14-07-02 08:31:09 VAPOR PROCESSOR OVER PRESSURE DAILY 90% 5.00 14-04-26 08:32:06 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 15.71 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 15-01-28 10:58:53 READINESS ISD:PP EVR:NNN EVR READINESS PENDING 15-01-28 10:58:53 ISD STARTUP 15-01-28 10:58:00 ISD SHUTDOWN 15-01-27 08:37:59 COLLECTION TEST HH03 GRADE TEST MANUALLY CLEARED 15-01-27 08:31:24 FLOW PERFORMANCE BLK DISABLED FP 03 BLEND3 15-01-19 18:10:27 PROCESSOR MODE AUTOMATIC 15-01-19 14:10:13 PROCESSOR MODE MANUAL 15-01-19 14:09:58 PROCESSOR MODE AUTOMATIC 15-01-19 14:03:50 PROCESSOR MODE MANUAL 15-01-19 13:29:24 PROCESSOR MODE AUTOMATIC