Loading...
HomeMy WebLinkAboutFMC Results 2016MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of CaliforniaAuthority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A.General Information Facility Name:Bldg. No.: Site Address:City:Zip: Facility Contact Person: Contact Phone No.: Make/Model of Monitoring System:Date of Testing/Servicing: B.Inventory of Equipment Tested/Certified Check the appropriate boxes to indicate specific equipment inspected/serviced: Tank ID:Tank ID: In-Tank Gauging Probe.Model:In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model:Annular Space or Vault Sensor.Model: Piping Sump / Trench Sensor(s).Model:Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model:Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model:Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Electronic LineLeak Detector.Model: Tank Overfill / High-Level Sensor.Model:Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2).Other (specify equipment type and model in Section E on Page 2). Tank ID:Tank ID: In-Tank Gauging Probe.Model:In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model:Annular Space or Vault Sensor.Model: Piping Sump / TrenchSensor(s).Model:Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model:Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model:Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Electronic Line Leak Detector.Model: Tank Overfill / High-Level Sensor.Model:Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2).Other (specify equipment type and model in Section E on Page 2). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C.Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers’ guidelines. Attached to this Certification is information (e.g. manufacturers' checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report;(check all that apply):System set-up Alarm history report Technician Name (print):Signature: Certification No.:License. No.:804904 Testing Company Name:Confidence UST Services, Inc.Phone No.:(800)339-9930 Site Address:Date of Testing/Servicing: Page 1 of 3 #3347Fastrip#26 2698OswellStreet Bakersfield93306 OmeroGarcia (661)393-7000 GilbarcoEMC 08/04/2016 12,000gal.Regular#1 847390-107 794390-420 794380-208 FX1V 847390-107 12,000gal.Regular#2 847390-107 794390-420 794380-208 NA 847390-107 12,000gal.Super 847390-107 794390-420 794380-208 FX1V 847390-107 12,000gal.Diesel 847390-107 794390-420 794380-208 FX1DV 847390-107 1-2 794380-208 3-4 794380-208 5-6 794380-208 794380-208 7-8 TransitionSump(North) 794380-208 TransitionSump(South) 794380-208 Cameron Mason B40738 2698OswellStreet Bakersfield,CA93306 08/04/2016 794380-208 794380-208 794380-208 794380-208 Monitoring System Certification D.Results of Testing/Servicing Software Version Installed: Complete the following checklist: Yes No*Isthe audible alarm operational? Yes No*Is the visual alarm operational? Yes No*Were all sensors visually inspected, functionally tested, and confirmed operational? Yes No*Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* N/A If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) operational? Yes No* N/A For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) Sump/Trench Sensors; Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection? Yes; No. Yes No* N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent oftank capacity does the alarm trigger? % Yes*NoWas any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes*NoWas liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) Product; Water. If yes, describe causes in Section E, below. Yes No*Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable Yes No*Is all monitoring equipment operational per manufacturer’s specifications? * In Section E below, describe how and when these deficiencies were or will be corrected. E.Comments: Page 2 of 3 331.01 90 Solid state flasher was was holding steady. Replaced with new and verified operational. Monitoring System Certification F.In-Tank Gauging / SIR Equipment: Check this box if tank gauging is used only for inventory control. Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: Yes No*Has all input wiring been inspected for proper entry and termination, including testing for ground faults? Yes No*Were all tank gauging probes visually inspected for damage and residue buildup? Yes No*Was accuracy of system product level readings tested? Yes No*Was accuracy of system water level readings tested? Yes No*Were all probes reinstalled properly? Yes No*Were all items on the equipment manufacturer’s maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. G.Line Leak Detectors (LLD):Check this box if LLDs are not installed. Complete the following checklist: Yes No* N/A For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? (Check all that apply)Simulated leak rate: 3 g.p.h.; 0.1 g.p.h ; 0.2 g.p.h. Yes No*Were all LLDs confirmed operational and accurate within regulatory requirements? Yes No*Was the testing apparatus properly calibrated? Yes No* N/A For mechanical LLDs, does the LLD restrict product flow if it detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? Yes No* N/A For electronic LLDs, have all accessible wiring connections been visually inspected? Yes No*Were all items on the equipment manufacturer’s maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. H.Comments: Page 3 of 3 Leak detector in 87 STP failed. Replaced with new and verified operational. Leak Detector Test Results Sheet Customer Address: Work Order: Site Address: Test Date: Site Contact: Phone: Technician: Phone: 800-339-9930 ICC No.: Product Type LLD Type Model Serial No. Check Valve Holding Pressure Bleed Off ML. Leak Rate Tested: Pass/Fail 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi Technician Name: Technician No.: Signature: Date: JacoHill P.O.Box82515 Bakersfield,CA93380-2515 37010 08/04/2016 8111231-UT Regular Mechanical FX1V Cameron Mason (661)393-7000OmeroGarcia Bakersfield,CA93306 2698OswellStreet #3347Fastrip#26 13 PSI130 ml Pass FX1VMechanicalPremium 14 PSI160 ml Pass FX1DVMechanicalDiesel 32 PSI110 ml Pass Cameron Mason 8111231-UT 08/04/2016 Responses Received: 200 FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 AUG 4, 2016 8:20 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNL 1 5332 43.80 0.8 89.5 6668 2 DIESEL 4019 35.41 0.8 87.2 7981 3 PNL 5131 42.53 0.0 87.3 6869 4 UNL 2 5618 45.60 0.6 89.0 6382 I90500 AUG 4, 2016 8:20 AM SOFTWARE REVISION LEVEL VERSION 330.01 SOFTWARE# 346330-100-B CREATED - 10.07.23.17.25 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I50500 AUG 4, 2016 8:20 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 AUG 4, 2016 8:20 AM SHIFT TIME 1 : 6:00 AM I50202 AUG 4, 2016 8:20 AM SHIFT TIME 2 : DISABLED I50203 AUG 4, 2016 8:20 AM SHIFT TIME 3 : DISABLED I50204 AUG 4, 2016 8:20 AM SHIFT TIME 4 : DISABLED I54600 AUG 4, 2016 8:20 AM TANK PER TST NEEDED WRN: DISABLED I54900 AUG 4, 2016 8:20 AM TANK ANN TST NEEDED WRN: DISABLED I55300 AUG 4, 2016 8:20 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 AUG 4, 2016 8:20 AM LINE PER TST NEEDED WRN: DISABLED I55900 AUG 4, 2016 8:20 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 AUG 4, 2016 8:20 AM PRINT TC VOLUMES ENABLED I50E00 AUG 4, 2016 8:20 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 AUG 4, 2016 8:20 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 AUG 4, 2016 8:20 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 AUG 4, 2016 8:20 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 AUG 4, 2016 8:20 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 AUG 4, 2016 8:20 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 AUG 4, 2016 8:20 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 AUG 4, 2016 8:20 AM TANK CHART SECURITY DISABLED I5BD00 AUG 4, 2016 8:20 AM CUSTOM ALARM LABELS DISABLED I56000 AUG 4, 2016 8:20 AM MASS/DENSITY DISABLED I88101 AUG 4, 2016 8:20 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 AUG 4, 2016 8:20 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 AUG 4, 2016 8:21 AM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88104 AUG 4, 2016 8:21 AM I88105 AUG 4, 2016 8:21 AM I88106 AUG 4, 2016 8:21 AM I52000 AUG 4, 2016 8:21 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE ??? 4, 2016 DISABLED 2 ON DATE ??? 4, 2016 DISABLED 3 ON DATE ??? 4, 2016 DISABLED 4 ON DATE ??? 4, 2016 DISABLED 5 ON DATE ??? 4, 2016 DISABLED 6 ON DATE ??? 4, 2016 DISABLED 7 ON DATE ??? 4, 2016 DISABLED 8 ON DATE ??? 4, 2016 DISABLED I60100 AUG 4, 2016 8:21 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL 1 ON 2 DIESEL ON 3 PNL ON 4 UNL 2 ON I60200 AUG 4, 2016 8:21 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL 1 2 DIESEL 3 PNL 4 UNL 2 I60300 AUG 4, 2016 8:21 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL 1 1 2 DIESEL 2 3 PNL 3 4 UNL 2 4 I60900 AUG 4, 2016 8:21 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL 1 0.000700 2 DIESEL 0.000450 3 PNL 0.000700 4 UNL 2 0.000700 I60700 AUG 4, 2016 8:21 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL 1 96.00 2 DIESEL 96.00 3 PNL 96.00 4 UNL 2 96.00 I60A00 AUG 4, 2016 8:21 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNL 1 1 PT 12000 2 DIESEL 1 PT 12000 3 PNL 1 PT 12000 4 UNL 2 1 PT 12000 I60400 AUG 4, 2016 8:21 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 12000 2 DIESEL 12000 3 PNL 12000 4 UNL 2 12000 I60500 AUG 4, 2016 8:21 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12000 0 0 0 2 DIESEL 12000 0 0 0 3 PNL 12000 0 0 0 4 UNL 2 12000 0 0 0 I60600 AUG 4, 2016 8:21 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 DIESEL 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PNL 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 UNL 2 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 AUG 4, 2016 8:21 AM TANK PRODUCT LABEL METER DATA 1 UNL 1 NO 2 DIESEL NO 3 PNL NO 4 UNL 2 NO I62F00 AUG 4, 2016 8:21 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNL 1 4.0 IN. 2 DIESEL 4.0 IN. 3 PNL 4.0 IN. 4 UNL 2 3.0 IN. I62700 AUG 4, 2016 8:21 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 2.0 2 DIESEL 2.0 3 PNL 2.0 4 UNL 2 2.0 9999FF1B I62400 AUG 4, 2016 8:21 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 3.0 2 DIESEL 3.0 3 PNL 3.0 4 UNL 2 3.0 I62800 AUG 4, 2016 8:21 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 12000 2 DIESEL 12000 3 PNL 12000 4 UNL 2 12000 I62300 AUG 4, 2016 8:21 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 10800 2 DIESEL 10800 3 PNL 10800 4 UNL 2 10800 I62200 AUG 4, 2016 8:21 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 11400 2 DIESEL 11400 3 PNL 11400 4 UNL 2 11400 I62900 AUG 4, 2016 8:21 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1200 2 DIESEL 1200 3 PNL 1200 4 UNL 2 1200 I62100 AUG 4, 2016 8:21 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1200 2 DIESEL 1200 3 PNL 1200 4 UNL 2 1200 I62600 AUG 4, 2016 8:21 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 DIESEL 99 3 PNL 99 4 UNL 2 99 I62500 AUG 4, 2016 8:21 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 DIESEL 99 3 PNL 99 4 UNL 2 99 I60800 AUG 4, 2016 8:21 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNL 1 0.00 2 DIESEL 0.00 3 PNL 0.00 4 UNL 2 0.00 I60B00 AUG 4, 2016 8:21 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 AUG 4, 2016 8:21 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNL 1 0.00 2 DIESEL 0.00 3 PNL 0.00 4 UNL 2 0.00 I61200 AUG 4, 2016 8:21 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL 1 4 NONE 2 DIESEL NONE NONE 3 PNL NONE NONE 4 UNL 2 1 NONE I63600 AUG 4, 2016 8:21 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 120 2 DIESEL 120 3 PNL 120 4 UNL 2 120 I62A00 AUG 4, 2016 8:21 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 0 2 DIESEL 0 3 PNL 0 4 UNL 2 0 I62C00 AUG 4, 2016 8:21 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNL 1 STANDARD 2 DIESEL STANDARD 3 PNL STANDARD 4 UNL 2 STANDARD I62D00 AUG 4, 2016 8:21 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNL 1 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 2 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 3 PNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 4 UNL 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 AUG 4, 2016 8:21 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNL 1 OFF OFF 2 DIESEL OFF OFF 3 PNL OFF OFF 4 UNL 2 OFF OFF I63000 AUG 4, 2016 8:21 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNL 1 OFF 2 DIESEL OFF 3 PNL OFF 4 UNL 2 OFF I63200 AUG 4, 2016 8:21 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNL 1 OFF 2 DIESEL OFF 3 PNL OFF 4 UNL 2 OFF I61000 AUG 4, 2016 8:21 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNL 1 1 2 DIESEL 1 3 PNL 1 4 UNL 2 1 I63A00 AUG 4, 2016 8:21 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNL 1 10.00% 2 DIESEL 10.00% 3 PNL 10.00% 4 UNL 2 10.00% I61100 AUG 4, 2016 8:21 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JUL 23, 2010 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 AUG 4, 2016 8:21 AM CSLD PROBABLITY OF DETECTION I61400 AUG 4, 2016 8:21 AM CSLD CLIMATE FACTOR I61600 AUG 4, 2016 8:21 AM TANK PRODUCT LABEL CAL UPDATE 1 UNL 1 IMMEDIATE 2 DIESEL IMMEDIATE 3 PNL IMMEDIATE 4 UNL 2 IMMEDIATE I61A00 AUG 4, 2016 8:21 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNL 1 DISABLED 2 DIESEL DISABLED 3 PNL DISABLED 4 UNL 2 DISABLED I61B00 AUG 4, 2016 8:21 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 AUG 4, 2016 8:21 AM CSLD REPORT ONLY I62B00 AUG 4, 2016 8:21 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNL 1 ??? 0, 0 2 DIESEL ??? 0, 0 3 PNL ??? 0, 0 4 UNL 2 ??? 0, 0 I63300 AUG 4, 2016 8:21 AM LEAK TEST REPORT FORMAT: NORMAL I63400 AUG 4, 2016 8:21 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 0 2 DIESEL 0 3 PNL 0 4 UNL 2 0 I63500 AUG 4, 2016 8:21 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1 2 DIESEL 1 3 PNL 1 4 UNL 2 1 I63900 AUG 4, 2016 8:21 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNL 1 END FACTOR: NONE 2 DIESEL END FACTOR: NONE 3 PNL END FACTOR: NONE 4 UNL 2 END FACTOR: NONE I78000 AUG 4, 2016 8:21 AM I77700 AUG 4, 2016 8:21 AM I77800 AUG 4, 2016 8:21 AM I78C00 AUG 4, 2016 8:21 AM I78300 AUG 4, 2016 8:21 AM I78F00 AUG 4, 2016 8:21 AM I78700 AUG 4, 2016 8:21 AM I70200 AUG 4, 2016 8:21 AM LIQUID LABEL DEVICE LABEL 1 UNL 1 STP 2 UNL 1 ANN 3 DSL STP 4 DSL ANN 5 6 PNL ANN 7 UNL 2 STP 8 UNL 2 ANN 9 DISP 1-2 10 DISP 3-4 11 DISP 5-6 12 DISP 7-8 13 TRANS SUMP NO 14 TRANS SUMP SO 15 PNL STP 16 UNL 2 ANN I70300 AUG 4, 2016 8:21 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL 1 STP TRI-STATE (SINGLE FLOAT) 2 UNL 1 ANN TRI-STATE (SINGLE FLOAT) 3 DSL STP TRI-STATE (SINGLE FLOAT) 4 DSL ANN TRI-STATE (SINGLE FLOAT) 5 TRI-STATE (SINGLE FLOAT) 6 PNL ANN TRI-STATE (SINGLE FLOAT) 7 UNL 2 STP TRI-STATE (SINGLE FLOAT) 8 UNL 2 ANN TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 3-4 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 7-8 TRI-STATE (SINGLE FLOAT) 13 TRANS SUMP NO TRI-STATE (SINGLE FLOAT) 14 TRANS SUMP SO TRI-STATE (SINGLE FLOAT) 15 PNL STP TRI-STATE (SINGLE FLOAT) 16 UNL 2 ANN TRI-STATE (SINGLE FLOAT) I70400 AUG 4, 2016 8:21 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL 1 STP STP SUMP 2 UNL 1 ANN ANNULAR SPACE 3 DSL STP STP SUMP 4 DSL ANN ANNULAR SPACE 5 OTHER SENSORS 6 PNL ANN ANNULAR SPACE 7 UNL 2 STP STP SUMP 8 UNL 2 ANN ANNULAR SPACE 9 DISP 1-2 DISPENSER PAN 10 DISP 3-4 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 7-8 DISPENSER PAN 13 TRANS SUMP NO PIPING SUMP 14 TRANS SUMP SO PIPING SUMP 15 PNL STP STP SUMP 16 UNL 2 ANN ANNULAR SPACE I74200 AUG 4, 2016 8:21 AM I74300 AUG 4, 2016 8:21 AM I74400 AUG 4, 2016 8:21 AM I74700 AUG 4, 2016 8:21 AM I74800 AUG 4, 2016 8:21 AM I74900 AUG 4, 2016 8:21 AM I7BC00 AUG 4, 2016 8:21 AM I80200 AUG 4, 2016 8:21 AM I80300 AUG 4, 2016 8:21 AM I80400 AUG 4, 2016 8:21 AM I80700 AUG 4, 2016 8:21 AM RELAY LABEL DEVICE LABEL 1 UNL 1 2 PNL 3 DSL 4 5 OVERFILL ALARM 6 7 8 I80900 AUG 4, 2016 8:21 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL 1 NORMALLY OPEN 2 PNL NORMALLY OPEN 3 DSL NORMALLY CLOSED 4 NORMALLY OPEN 5 OVERFILL ALARM NORMALLY OPEN 6 NORMALLY OPEN 7 NORMALLY OPEN 8 NORMALLY OPEN I80B00 AUG 4, 2016 8:21 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 1 2 PNL 3 3 DSL NONE 4 NONE 5 OVERFILL ALARM NONE 6 NONE 7 NONE 8 NONE I80A00 AUG 4, 2016 8:21 AM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL 1 PUMP CONTROL OUTPUT 2 PNL PUMP CONTROL OUTPUT 3 DSL STANDARD 4 STANDARD 5 OVERFILL ALARM STANDARD 6 STANDARD 7 STANDARD 8 STANDARD I80C00 AUG 4, 2016 8:21 AM I80800 AUG 4, 2016 8:21 AM RELAY SETUP REPORT R 1:UNL 1 TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SHORT ALARM L 7:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:PNL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L15:FUEL ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L15:SENSOR OUT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L15:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DSL TYPE: STANDARD NORMALLY CLOSED TANK #: NONE LIQUID SENSOR ALMS L 3:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 5:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 6: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 7: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 8: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 AUG 4, 2016 8:22 AM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 AUG 4, 2016 8:22 AM I72300 AUG 4, 2016 8:22 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 PS 3-4 VAPOR PRESSURE 02 FM 1-2 AIR FLOW METER 03 FM 3-4 AIR FLOW METER 04 FM 5-6 AIR FLOW METER 05 FM 7-8 AIR FLOW METER 06 UNKNOWN 07 UNKNOWN 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 AUG 4, 2016 8:22 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 AUG 4, 2016 8:22 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 AUG 4, 2016 8:22 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 VAPOR PROCESSOR TYPE NONE IV4700 AUG 4, 2016 8:22 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ASSESSMENT TIME START TIME: 10:49 AM TIME DELAY MINUTES: 1 IV5200 AUG 4, 2016 8:22 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ACCEPT HIGH ORVR: NO IV4A00 AUG 4, 2016 8:22 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 01 01 01 BLEND3 02 02 02 01 BLEND3 03 03 03 02 BLEND3 04 04 04 02 BLEND3 05 05 05 03 BLEND3 06 06 06 03 BLEND3 07 07 07 04 BLEND3 08 08 08 04 BLEND3 IV4B00 AUG 4, 2016 8:22 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 AUG 4, 2016 8:22 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 AUG 4, 2016 8:22 AM ISD VERSION: 01.03 Responses Received: I10200 AUG 4, 2016 8:22 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39999 39618 2 4 PROBE / G.T. 164016 163104 3 INTERSTITIAL BD 202660 201846 4 INTERSTITIAL BD 201742 201212 5 UNUSED 4995371 4940850 6 UNUSED 4979090 4932385 7 UNUSED 4978325 4932552 8 UNUSED 4971404 4930859 9 STP SENSE BOARD 33199 33172 10 RELAY BOARD 14965 14979 11 RELAY BOARD 14945 14937 12 UNUSED 4975339 4934285 13 UNUSED 4970546 4932863 14 UNUSED 4971331 4931421 15 UNUSED 4970153 4938987 16 UNUSED 4969843 4932403 COMM 1 ELEC DISP INT. 100658 100570 COMM 2 RS232 SERIAL BD 14945 14937 COMM 3 RS232 SERIAL BD 15007 15021 COMM 4 UNUSED 4972447 4935936 COMM 5 UNUSED 4969347 4933010 COMM 6 UNUSED 4967653 4930167 I90200 AUG 4, 2016 8:22 AM SOFTWARE REVISION LEVEL VERSION 330.01 SOFTWARE# 346330-100-B CREATED - 10.07.23.17.25 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 AUG 4, 2016 8:22 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK UNL 1 OVERFILL ALARM CLEAR 7-30-16 3:59PM T 1 TANK UNL 1 OVERFILL ALARM ALARM 7-30-16 3:50PM E 1 OTHER COMMUNICATION ALARM CLEAR 7-27-16 10:50AM E 1 OTHER COMMUNICATION ALARM ALARM 7-27-16 10:22AM T 2 TANK DIESEL PROBE OUT CLEAR 7-27-16 10:19AM E 1 OTHER COMMUNICATION ALARM CLEAR 7-27-16 9:52AM E 1 OTHER COMMUNICATION ALARM ALARM 7-27-16 9:49AM T 3 TANK PNL PROBE OUT CLEAR 7-27-16 9:39AM T 3 TANK PNL OVERFILL ALARM CLEAR 7-27-16 9:39AM T 3 TANK PNL PROBE OUT ALARM 7-27-16 9:39AM T 3 TANK PNL OVERFILL ALARM ALARM 7-27-16 9:38AM T 2 TANK DIESEL OVERFILL ALARM CLEAR 7-27-16 9:37AM T 2 TANK DIESEL PROBE OUT ALARM 7-27-16 9:37AM T 2 TANK DIESEL OVERFILL ALARM ALARM 7-27-16 9:37AM T 1 TANK UNL 1 PROBE OUT CLEAR 7-27-16 9:35AM T 1 TANK UNL 1 PROBE OUT ALARM 7-27-16 9:35AM T 1 TANK UNL 1 OVERFILL ALARM CLEAR 7-27-16 9:34AM T 1 TANK UNL 1 OVERFILL ALARM ALARM 7-27-16 9:34AM T 4 TANK UNL 2 PROBE OUT CLEAR 7-27-16 9:34AM T 4 TANK UNL 2 OVERFILL ALARM CLEAR 7-27-16 9:33AM T 4 TANK UNL 2 PROBE OUT ALARM 7-27-16 9:33AM T 4 TANK UNL 2 OVERFILL ALARM ALARM 7-27-16 9:33AM L 4 ANNULAR DSL ANN FUEL ALARM CLEAR 7-27-16 9:29AM L 6 ANNULAR PNL ANN FUEL ALARM CLEAR 7-27-16 9:28AM L 6 ANNULAR PNL ANN FUEL ALARM ALARM 7-27-16 9:28AM L 4 ANNULAR DSL ANN FUEL ALARM ALARM 7-27-16 9:28AM L 8 ANNULAR UNL 2 ANN FUEL ALARM CLEAR 7-27-16 9:27AM L 2 ANNULAR UNL 1 ANN FUEL ALARM CLEAR 7-27-16 9:27AM L 2 ANNULAR UNL 1 ANN FUEL ALARM ALARM 7-27-16 9:26AM L 8 ANNULAR UNL 2 ANN FUEL ALARM ALARM 7-27-16 9:26AM L14 PIPE TRANS SUMP SO FUEL ALARM CLEAR 7-27-16 9:25AM L14 PIPE TRANS SUMP SO FUEL ALARM ALARM 7-27-16 9:24AM L13 PIPE TRANS SUMP NO FUEL ALARM CLEAR 7-27-16 9:23AM L13 PIPE TRANS SUMP NO FUEL ALARM ALARM 7-27-16 9:23AM L12 DISP PAN DISP 7-8 FUEL ALARM CLEAR 7-27-16 9:22AM L12 DISP PAN DISP 7-8 FUEL ALARM ALARM 7-27-16 9:22AM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 7-27-16 9:21AM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 7-27-16 9:20AM L10 DISP PAN DISP 3-4 FUEL ALARM CLEAR 7-27-16 9:19AM L10 DISP PAN DISP 3-4 FUEL ALARM ALARM 7-27-16 9:18AM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 7-27-16 9:16AM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 7-27-16 9:15AM L 7 STP SUMP UNL 2 STP FUEL ALARM CLEAR 7-27-16 9:13AM L 7 STP SUMP UNL 2 STP FUEL ALARM ALARM 7-27-16 9:13AM L 1 STP SUMP UNL 1 STP FUEL ALARM CLEAR 7-27-16 9:11AM L 1 STP SUMP UNL 1 STP FUEL ALARM ALARM 7-27-16 9:11AM L 3 STP SUMP DSL STP FUEL ALARM CLEAR 7-27-16 9:09AM L 3 STP SUMP DSL STP FUEL ALARM ALARM 7-27-16 9:09AM L15 STP SUMP PNL STP FUEL ALARM CLEAR 7-27-16 9:08AM L15 STP SUMP PNL STP FUEL ALARM ALARM 7-27-16 9:08AM I11200 AUG 4, 2016 8:23 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME OTHER ISD GROSS PRES WARN CLEAR 7-28-16 1:30PM OTHER ISD GROSS PRES WARN ALARM 7-28-16 10:51AM T 4 TANK UNL 2 INVALID FUEL LEVEL CLEAR 7-27-16 8:50AM T 4 TANK UNL 2 DELIVERY NEEDED CLEAR 7-27-16 8:50AM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 7-27-16 8:50AM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 7-27-16 8:50AM T 2 TANK DIESEL DELIVERY NEEDED ALARM 7-27-16 8:49AM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 7-27-16 8:48AM T 4 TANK UNL 2 DELIVERY NEEDED ALARM 7-27-16 8:47AM T 4 TANK UNL 2 INVALID FUEL LEVEL ALARM 7-27-16 8:47AM SYSTEM PRINTER ERROR CLEAR 7-22-16 10:36AM SYSTEM PAPER OUT CLEAR 7-22-16 10:36AM SYSTEM PRINTER ERROR ALARM 7-22-16 10:36AM SYSTEM PRINTER ERROR CLEAR 7-22-16 10:34AM SYSTEM PRINTER ERROR ALARM 7-22-16 10:34AM SYSTEM PAPER OUT ALARM 7-22-16 10:34AM SYSTEM PAPER OUT CLEAR 6-29-16 10:42PM SYSTEM PAPER OUT ALARM 6-29-16 10:40PM SYSTEM PRINTER ERROR CLEAR 6-02-16 2:55PM SYSTEM PAPER OUT CLEAR 6-02-16 2:55PM SYSTEM PRINTER ERROR ALARM 6-02-16 2:55PM SYSTEM PAPER OUT ALARM 6-02-16 2:55PM SYSTEM PRINTER ERROR CLEAR 6-02-16 6:54AM SYSTEM PAPER OUT CLEAR 6-02-16 6:54AM SYSTEM PRINTER ERROR ALARM 6-02-16 6:54AM SYSTEM PRINTER ERROR CLEAR 6-02-16 6:54AM SYSTEM PAPER OUT ALARM 6-02-16 6:54AM SYSTEM PAPER OUT CLEAR 6-02-16 6:54AM SYSTEM PAPER OUT ALARM 6-02-16 6:54AM SYSTEM PAPER OUT CLEAR 6-02-16 6:54AM SYSTEM PAPER OUT ALARM 6-02-16 6:54AM SYSTEM PAPER OUT CLEAR 6-02-16 6:54AM SYSTEM PRINTER ERROR ALARM 6-02-16 6:53AM SYSTEM PAPER OUT ALARM 6-02-16 6:14AM L 8 ANNULAR UNL 2 ANN SETUP DATA WARNING CLEAR 6-01-16 4:27PM L 8 ANNULAR UNL 2 ANN SETUP DATA WARNING ALARM 6-01-16 4:27PM L16 ANNULAR UNL 2 ANN SETUP DATA WARNING CLEAR 6-01-16 4:22PM L16 ANNULAR UNL 2 ANN SETUP DATA WARNING ALARM 6-01-16 4:21PM L15 STP SUMP PNL STP SETUP DATA WARNING CLEAR 6-01-16 2:40PM L15 STP SUMP PNL STP SETUP DATA WARNING ALARM 6-01-16 2:40PM L 4 ANNULAR DSL ANN SETUP DATA WARNING CLEAR 6-01-16 2:29PM L 4 ANNULAR DSL ANN SETUP DATA WARNING ALARM 6-01-16 2:29PM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 5-09-16 8:21PM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 5-09-16 7:51PM SYSTEM PRINTER ERROR CLEAR 5-05-16 11:26AM SYSTEM PRINTER ERROR ALARM 5-05-16 11:26AM T 3 TANK PNL DELIVERY NEEDED CLEAR 4-28-16 12:47PM T 3 TANK PNL DELIVERY NEEDED ALARM 4-27-16 7:03PM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 3-28-16 12:06PM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 3-27-16 10:50AM I20600 AUG 4, 2016 8:23 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 TANK ALARM HISTORY TANK 1 UNL 1 SETUP DATA WARNING JUL 30, 2014 9:29 AM OVERFILL ALARM JUL 30, 2016 3:50 PM JUL 27, 2016 9:34 AM JUL 17, 2016 11:51 PM LOW PRODUCT ALARM JUL 27, 2016 8:48 AM MAY 9, 2016 7:51 PM AUG 10, 2015 10:04 AM SUDDEN LOSS ALARM JUL 27, 2016 8:46 AM AUG 10, 2015 10:03 AM JUL 23, 2015 2:23 AM HIGH PRODUCT ALARM AUG 10, 2015 10:06 AM AUG 5, 2014 10:12 AM JUL 30, 2014 9:29 AM INVALID FUEL LEVEL AUG 10, 2015 10:04 AM JUL 25, 2015 4:19 PM PROBE OUT JUL 27, 2016 9:35 AM JUL 27, 2016 8:47 AM AUG 10, 2015 10:06 AM DELIVERY NEEDED JUL 27, 2016 8:48 AM MAY 9, 2016 7:51 PM AUG 10, 2015 10:04 AM LOW TEMP WARNING AUG 10, 2015 10:07 AM AUG 5, 2015 10:07 AM AUG 7, 2013 9:13 AM TANK 2 DIESEL SETUP DATA WARNING JUL 30, 2014 9:30 AM OVERFILL ALARM JUL 27, 2016 9:37 AM AUG 10, 2015 10:31 AM AUG 5, 2014 10:17 AM LOW PRODUCT ALARM JUL 27, 2016 8:49 AM FEB 22, 2016 11:02 AM FEB 1, 2016 3:47 PM HIGH PRODUCT ALARM AUG 10, 2015 10:31 AM AUG 5, 2015 10:09 AM AUG 5, 2014 10:17 AM INVALID FUEL LEVEL DEC 13, 2015 10:28 AM AUG 7, 2013 9:48 AM AUG 11, 2011 8:48 AM PROBE OUT JUL 27, 2016 9:37 AM JUL 27, 2016 8:49 AM AUG 10, 2015 10:32 AM DELIVERY NEEDED JUL 27, 2016 8:49 AM FEB 22, 2016 11:01 AM FEB 1, 2016 3:46 PM LOW TEMP WARNING AUG 5, 2015 10:10 AM AUG 5, 2014 10:18 AM JUL 31, 2013 11:19 AM TANK 3 PNL SETUP DATA WARNING JUL 30, 2014 9:31 AM OVERFILL ALARM JUL 27, 2016 9:38 AM AUG 10, 2015 10:23 AM AUG 5, 2015 10:12 AM LOW PRODUCT ALARM APR 27, 2016 7:12 PM FEB 20, 2016 5:19 PM AUG 30, 2013 4:50 AM SUDDEN LOSS ALARM AUG 10, 2015 10:13 AM AUG 5, 2014 9:19 AM AUG 7, 2012 9:00 AM HIGH PRODUCT ALARM AUG 10, 2015 10:23 AM AUG 5, 2015 10:12 AM JUL 30, 2014 9:31 AM INVALID FUEL LEVEL FEB 21, 2016 4:15 PM AUG 5, 2015 10:13 AM AUG 11, 2011 9:26 AM PROBE OUT JUL 27, 2016 9:39 AM JUL 27, 2016 8:49 AM AUG 10, 2015 10:23 AM DELIVERY NEEDED APR 27, 2016 7:03 PM FEB 20, 2016 5:19 PM AUG 30, 2013 4:49 AM LOW TEMP WARNING AUG 10, 2015 10:14 AM AUG 5, 2014 10:20 AM AUG 7, 2013 9:50 AM TANK 4 UNL 2 SETUP DATA WARNING JUL 30, 2014 9:32 AM OVERFILL ALARM JUL 27, 2016 9:33 AM JUL 20, 2016 6:57 AM FEB 17, 2016 12:11 AM LOW PRODUCT ALARM JUL 27, 2016 8:47 AM AUG 10, 2015 10:08 AM AUG 5, 2015 10:03 AM SUDDEN LOSS ALARM JUL 27, 2016 8:46 AM AUG 10, 2015 10:03 AM AUG 7, 2012 8:54 AM HIGH PRODUCT ALARM AUG 10, 2015 10:10 AM JUL 30, 2014 9:32 AM AUG 7, 2013 9:43 AM INVALID FUEL LEVEL JUL 27, 2016 8:47 AM JUL 31, 2013 10:09 AM JUL 31, 2013 9:18 AM PROBE OUT JUL 27, 2016 9:33 AM JUL 27, 2016 8:46 AM AUG 10, 2015 10:10 AM DELIVERY NEEDED JUL 27, 2016 8:47 AM AUG 10, 2015 10:08 AM AUG 5, 2015 10:03 AM LOW TEMP WARNING AUG 10, 2015 10:11 AM SEP 19, 2013 4:21 PM AUG 7, 2013 9:44 AM I38200 AUG 4, 2016 8:23 AM I30200 AUG 4, 2016 8:23 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP JUL 27, 2016 9:11 AM FUEL ALARM JUL 27, 2016 9:04 AM SENSOR OUT ALARM JUN 1, 2016 1:44 PM SENSOR OUT ALARM 2 UNL 1 ANN JUL 27, 2016 9:26 AM FUEL ALARM JUL 27, 2016 9:05 AM SENSOR OUT ALARM JUN 2, 2016 5:23 PM SENSOR OUT ALARM 3 DSL STP JUL 27, 2016 9:09 AM FUEL ALARM JUL 27, 2016 9:05 AM SENSOR OUT ALARM JUN 1, 2016 1:44 PM SENSOR OUT ALARM 4 DSL ANN JUL 27, 2016 9:28 AM FUEL ALARM JUL 27, 2016 9:05 AM SENSOR OUT ALARM JUN 2, 2016 5:25 PM SENSOR OUT ALARM 6 PNL ANN JUL 27, 2016 9:28 AM FUEL ALARM JUL 27, 2016 9:05 AM SENSOR OUT ALARM JUN 2, 2016 3:16 PM SENSOR OUT ALARM 7 UNL 2 STP JUL 27, 2016 9:13 AM FUEL ALARM JUL 27, 2016 9:05 AM SENSOR OUT ALARM JUN 1, 2016 1:45 PM SENSOR OUT ALARM 8 UNL 2 ANN JUL 27, 2016 9:26 AM FUEL ALARM JUL 27, 2016 9:05 AM SENSOR OUT ALARM JUN 2, 2016 5:23 PM SENSOR OUT ALARM 9 DISP 1-2 JUL 27, 2016 9:15 AM FUEL ALARM JUL 27, 2016 9:04 AM SENSOR OUT ALARM JUN 1, 2016 1:44 PM SENSOR OUT ALARM 10 DISP 3-4 JUL 27, 2016 9:18 AM FUEL ALARM JUL 27, 2016 9:05 AM SENSOR OUT ALARM JUN 1, 2016 4:22 PM SENSOR OUT ALARM 11 DISP 5-6 JUL 27, 2016 9:20 AM FUEL ALARM JUL 27, 2016 9:04 AM SENSOR OUT ALARM JUN 2, 2016 10:05 AM SENSOR OUT ALARM 12 DISP 7-8 JUL 27, 2016 9:22 AM FUEL ALARM JUL 27, 2016 9:04 AM SENSOR OUT ALARM JUN 1, 2016 1:44 PM SENSOR OUT ALARM 13 TRANS SUMP NO JUL 27, 2016 9:23 AM FUEL ALARM JUL 27, 2016 9:04 AM SENSOR OUT ALARM JUN 1, 2016 4:06 PM SENSOR OUT ALARM 14 TRANS SUMP SO JUL 27, 2016 9:24 AM FUEL ALARM JUL 27, 2016 9:04 AM SENSOR OUT ALARM JUN 1, 2016 1:44 PM SENSOR OUT ALARM 15 PNL STP JUL 27, 2016 9:08 AM FUEL ALARM JUL 27, 2016 9:04 AM SENSOR OUT ALARM JUL 27, 2016 8:57 AM FUEL ALARM I31600 AUG 4, 2016 8:23 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 3-4 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 I40200 AUG 4, 2016 8:23 AM I40300 AUG 4, 2016 8:23 AM I34200 AUG 4, 2016 8:23 AM I34700 AUG 4, 2016 8:23 AM IV0100 AUG 4, 2016 8:23 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.03 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 16-07-28 10:51:02 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.35 16-03-28 10:50:56 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 16-03-27 10:50:39 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 16-03-17 10:50:23 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.78 16-03-10 10:50:19 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.56 16-03-03 10:50:25 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.41 16-02-25 10:51:11 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.36 16-02-18 10:50:38 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.53 16-02-11 10:51:11 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.31 16-02-04 10:51:41 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.34 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 15-12-16 10:01:58 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 15-12-16 10:01:58 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 15-12-15 10:01:56 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 12-08-18 10:02:49 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.70 11-08-25 10:02:34 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.05 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 16-07-28 13:30:56 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 16-07-27 10:50:50 READINESS ISD:PP EVR:PP ISD & EVR READY 16-07-27 09:02:51 READINESS ISD:PP EVR:NN EVR READINESS PENDING 16-07-27 09:02:51 ISD STARTUP 16-07-27 09:01:47 ISD SHUTDOWN 16-06-10 10:51:04 READINESS ISD:PP EVR:PP ISD & EVR READY 16-06-09 15:25:50 READINESS ISD:PP EVR:NN EVR READINESS PENDING 16-06-09 15:25:50 ISD STARTUP 16-06-09 15:08:44 ISD SHUTDOWN 16-06-02 10:50:23 READINESS ISD:PP EVR:PP ISD & EVR READY Responses Received: I10200 AUG 4, 2016 11:48 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39999 39540 2 4 PROBE / G.T. 164016 163021 3 INTERSTITIAL BD 202660 201519 4 INTERSTITIAL BD 201742 200973 5 UNUSED 4995371 4920376 6 UNUSED 4979090 4915735 7 UNUSED 4978325 4918465 8 UNUSED 4971404 4919200 9 STP SENSE BOARD 33199 33166 10 RELAY BOARD 14965 14972 11 RELAY BOARD 14945 14929 12 UNUSED 4975339 4925724 13 UNUSED 4970546 4921104 14 UNUSED 4971331 4919508 15 UNUSED 4970153 4924023 16 UNUSED 4969843 4919928 COMM 1 ELEC DISP INT. 100658 100560 COMM 2 RS232 SERIAL BD 14945 14951 COMM 3 RS232 SERIAL BD 15007 15014 COMM 4 UNUSED 4972447 4917408 COMM 5 UNUSED 4969347 4916358 COMM 6 UNUSED 4967653 4921503 I90200 AUG 4, 2016 11:48 AM SOFTWARE REVISION LEVEL VERSION 330.01 SOFTWARE# 346330-100-B CREATED - 10.07.23.17.25 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 AUG 4, 2016 11:48 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 3 TANK PNL PROBE OUT CLEAR 8-04-16 10:54AM T 3 TANK PNL PROBE OUT ALARM 8-04-16 10:54AM E 1 OTHER COMMUNICATION ALARM CLEAR 8-04-16 10:12AM E 1 OTHER COMMUNICATION ALARM ALARM 8-04-16 10:03AM T 3 TANK PNL OVERFILL ALARM CLEAR 8-04-16 9:45AM T 3 TANK PNL OVERFILL ALARM ALARM 8-04-16 9:43AM T 2 TANK DIESEL PROBE OUT CLEAR 8-04-16 9:42AM T 2 TANK DIESEL OVERFILL ALARM CLEAR 8-04-16 9:41AM T 2 TANK DIESEL PROBE OUT ALARM 8-04-16 9:41AM T 2 TANK DIESEL OVERFILL ALARM ALARM 8-04-16 9:40AM T 1 TANK UNL 1 PROBE OUT CLEAR 8-04-16 9:39AM T 1 TANK UNL 1 OVERFILL ALARM CLEAR 8-04-16 9:38AM T 1 TANK UNL 1 PROBE OUT ALARM 8-04-16 9:38AM T 4 TANK UNL 2 PROBE OUT CLEAR 8-04-16 9:38AM T 4 TANK UNL 2 PROBE OUT ALARM 8-04-16 9:37AM T 1 TANK UNL 1 OVERFILL ALARM ALARM 8-04-16 9:37AM T 4 TANK UNL 2 OVERFILL ALARM CLEAR 8-04-16 9:35AM T 4 TANK UNL 2 OVERFILL ALARM ALARM 8-04-16 9:34AM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 8-04-16 9:31AM L 7 STP SUMP UNL 2 STP SENSOR OUT ALARM CLEAR 8-04-16 9:31AM L 6 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 8-04-16 9:31AM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 8-04-16 9:31AM L 4 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 8-04-16 9:31AM L 3 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 8-04-16 9:31AM L13 PIPE TRANS SUMP NO SENSOR OUT ALARM CLEAR 8-04-16 9:31AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 8-04-16 9:31AM L 2 ANNULAR UNL 1 ANN SENSOR OUT ALARM CLEAR 8-04-16 9:31AM L15 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 8-04-16 9:31AM L14 PIPE TRANS SUMP SO SENSOR OUT ALARM CLEAR 8-04-16 9:31AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 8-04-16 9:31AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 8-04-16 9:31AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 8-04-16 9:31AM L14 PIPE TRANS SUMP SO SENSOR OUT ALARM ALARM 8-04-16 9:29AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 8-04-16 9:29AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 8-04-16 9:29AM L 4 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 8-04-16 9:29AM L 3 STP SUMP DSL STP SENSOR OUT ALARM ALARM 8-04-16 9:29AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 8-04-16 9:29AM L 2 ANNULAR UNL 1 ANN SENSOR OUT ALARM ALARM 8-04-16 9:29AM L15 STP SUMP PNL STP SENSOR OUT ALARM ALARM 8-04-16 9:29AM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 8-04-16 9:29AM L 7 STP SUMP UNL 2 STP SENSOR OUT ALARM ALARM 8-04-16 9:29AM L13 PIPE TRANS SUMP NO SENSOR OUT ALARM ALARM 8-04-16 9:29AM L 6 ANNULAR PNL ANN SENSOR OUT ALARM ALARM 8-04-16 9:29AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 8-04-16 9:29AM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM ALARM 8-04-16 9:29AM L14 PIPE TRANS SUMP SO FUEL ALARM CLEAR 8-04-16 9:26AM L14 PIPE TRANS SUMP SO FUEL ALARM ALARM 8-04-16 9:26AM L13 PIPE TRANS SUMP NO FUEL ALARM CLEAR 8-04-16 9:24AM L13 PIPE TRANS SUMP NO FUEL ALARM ALARM 8-04-16 9:24AM I11200 AUG 4, 2016 11:48 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 4 TANK UNL 2 LOW TEMP WARNING CLEAR 8-04-16 9:38AM T 4 TANK UNL 2 LOW TEMP WARNING ALARM 8-04-16 9:38AM SYSTEM PRINTER ERROR CLEAR 8-04-16 8:48AM SYSTEM PAPER OUT CLEAR 8-04-16 8:48AM SYSTEM PRINTER ERROR ALARM 8-04-16 8:48AM SYSTEM PAPER OUT ALARM 8-04-16 8:44AM T 2 TANK DIESEL INVALID FUEL LEVEL CLEAR 8-04-16 8:41AM T 2 TANK DIESEL INVALID FUEL LEVEL ALARM 8-04-16 8:40AM OTHER ISD GROSS PRES WARN CLEAR 7-28-16 1:30PM OTHER ISD GROSS PRES WARN ALARM 7-28-16 10:51AM T 4 TANK UNL 2 INVALID FUEL LEVEL CLEAR 7-27-16 8:50AM T 4 TANK UNL 2 DELIVERY NEEDED CLEAR 7-27-16 8:50AM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 7-27-16 8:50AM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 7-27-16 8:50AM T 2 TANK DIESEL DELIVERY NEEDED ALARM 7-27-16 8:49AM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 7-27-16 8:48AM T 4 TANK UNL 2 DELIVERY NEEDED ALARM 7-27-16 8:47AM T 4 TANK UNL 2 INVALID FUEL LEVEL ALARM 7-27-16 8:47AM SYSTEM PRINTER ERROR CLEAR 7-22-16 10:36AM SYSTEM PAPER OUT CLEAR 7-22-16 10:36AM SYSTEM PRINTER ERROR ALARM 7-22-16 10:36AM SYSTEM PRINTER ERROR CLEAR 7-22-16 10:34AM SYSTEM PRINTER ERROR ALARM 7-22-16 10:34AM SYSTEM PAPER OUT ALARM 7-22-16 10:34AM SYSTEM PAPER OUT CLEAR 6-29-16 10:42PM SYSTEM PAPER OUT ALARM 6-29-16 10:40PM SYSTEM PRINTER ERROR CLEAR 6-02-16 2:55PM SYSTEM PAPER OUT CLEAR 6-02-16 2:55PM SYSTEM PRINTER ERROR ALARM 6-02-16 2:55PM SYSTEM PAPER OUT ALARM 6-02-16 2:55PM SYSTEM PRINTER ERROR CLEAR 6-02-16 6:54AM SYSTEM PAPER OUT CLEAR 6-02-16 6:54AM SYSTEM PRINTER ERROR ALARM 6-02-16 6:54AM SYSTEM PRINTER ERROR CLEAR 6-02-16 6:54AM SYSTEM PAPER OUT ALARM 6-02-16 6:54AM SYSTEM PAPER OUT CLEAR 6-02-16 6:54AM SYSTEM PAPER OUT ALARM 6-02-16 6:54AM SYSTEM PAPER OUT CLEAR 6-02-16 6:54AM SYSTEM PAPER OUT ALARM 6-02-16 6:54AM SYSTEM PAPER OUT CLEAR 6-02-16 6:54AM SYSTEM PRINTER ERROR ALARM 6-02-16 6:53AM SYSTEM PAPER OUT ALARM 6-02-16 6:14AM L 8 ANNULAR UNL 2 ANN SETUP DATA WARNING CLEAR 6-01-16 4:27PM L 8 ANNULAR UNL 2 ANN SETUP DATA WARNING ALARM 6-01-16 4:27PM L16 ANNULAR UNL 2 ANN SETUP DATA WARNING CLEAR 6-01-16 4:22PM L16 ANNULAR UNL 2 ANN SETUP DATA WARNING ALARM 6-01-16 4:21PM L15 STP SUMP PNL STP SETUP DATA WARNING CLEAR 6-01-16 2:40PM L15 STP SUMP PNL STP SETUP DATA WARNING ALARM 6-01-16 2:40PM L 4 ANNULAR DSL ANN SETUP DATA WARNING CLEAR 6-01-16 2:29PM L 4 ANNULAR DSL ANN SETUP DATA WARNING ALARM 6-01-16 2:29PM I20600 AUG 4, 2016 11:48 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 TANK ALARM HISTORY TANK 1 UNL 1 SETUP DATA WARNING JUL 30, 2014 9:29 AM OVERFILL ALARM AUG 4, 2016 9:37 AM JUL 30, 2016 3:50 PM JUL 27, 2016 9:34 AM LOW PRODUCT ALARM JUL 27, 2016 8:48 AM MAY 9, 2016 7:51 PM AUG 10, 2015 10:04 AM SUDDEN LOSS ALARM AUG 4, 2016 8:38 AM JUL 27, 2016 8:46 AM AUG 10, 2015 10:03 AM HIGH PRODUCT ALARM AUG 10, 2015 10:06 AM AUG 5, 2014 10:12 AM JUL 30, 2014 9:29 AM INVALID FUEL LEVEL AUG 10, 2015 10:04 AM JUL 25, 2015 4:19 PM PROBE OUT AUG 4, 2016 9:38 AM AUG 4, 2016 8:39 AM JUL 27, 2016 9:35 AM DELIVERY NEEDED JUL 27, 2016 8:48 AM MAY 9, 2016 7:51 PM AUG 10, 2015 10:04 AM LOW TEMP WARNING AUG 10, 2015 10:07 AM AUG 5, 2015 10:07 AM AUG 7, 2013 9:13 AM TANK 2 DIESEL SETUP DATA WARNING JUL 30, 2014 9:30 AM OVERFILL ALARM AUG 4, 2016 9:40 AM JUL 27, 2016 9:37 AM AUG 10, 2015 10:31 AM LOW PRODUCT ALARM JUL 27, 2016 8:49 AM FEB 22, 2016 11:02 AM FEB 1, 2016 3:47 PM HIGH PRODUCT ALARM AUG 10, 2015 10:31 AM AUG 5, 2015 10:09 AM AUG 5, 2014 10:17 AM INVALID FUEL LEVEL AUG 4, 2016 8:40 AM DEC 13, 2015 10:28 AM AUG 7, 2013 9:48 AM PROBE OUT AUG 4, 2016 9:41 AM AUG 4, 2016 8:40 AM JUL 27, 2016 9:37 AM DELIVERY NEEDED JUL 27, 2016 8:49 AM FEB 22, 2016 11:01 AM FEB 1, 2016 3:46 PM LOW TEMP WARNING AUG 5, 2015 10:10 AM AUG 5, 2014 10:18 AM JUL 31, 2013 11:19 AM TANK 3 PNL SETUP DATA WARNING JUL 30, 2014 9:31 AM OVERFILL ALARM AUG 4, 2016 9:43 AM JUL 27, 2016 9:38 AM AUG 10, 2015 10:23 AM LOW PRODUCT ALARM APR 27, 2016 7:12 PM FEB 20, 2016 5:19 PM AUG 30, 2013 4:50 AM SUDDEN LOSS ALARM AUG 4, 2016 8:41 AM AUG 10, 2015 10:13 AM AUG 5, 2014 9:19 AM HIGH PRODUCT ALARM AUG 10, 2015 10:23 AM AUG 5, 2015 10:12 AM JUL 30, 2014 9:31 AM INVALID FUEL LEVEL FEB 21, 2016 4:15 PM AUG 5, 2015 10:13 AM AUG 11, 2011 9:26 AM PROBE OUT AUG 4, 2016 10:54 AM AUG 4, 2016 8:41 AM JUL 27, 2016 9:39 AM DELIVERY NEEDED APR 27, 2016 7:03 PM FEB 20, 2016 5:19 PM AUG 30, 2013 4:49 AM LOW TEMP WARNING AUG 10, 2015 10:14 AM AUG 5, 2014 10:20 AM AUG 7, 2013 9:50 AM TANK 4 UNL 2 SETUP DATA WARNING JUL 30, 2014 9:32 AM OVERFILL ALARM AUG 4, 2016 9:34 AM JUL 27, 2016 9:33 AM JUL 20, 2016 6:57 AM LOW PRODUCT ALARM JUL 27, 2016 8:47 AM AUG 10, 2015 10:08 AM AUG 5, 2015 10:03 AM SUDDEN LOSS ALARM AUG 4, 2016 8:38 AM JUL 27, 2016 8:46 AM AUG 10, 2015 10:03 AM HIGH PRODUCT ALARM AUG 10, 2015 10:10 AM JUL 30, 2014 9:32 AM AUG 7, 2013 9:43 AM INVALID FUEL LEVEL JUL 27, 2016 8:47 AM JUL 31, 2013 10:09 AM JUL 31, 2013 9:18 AM PROBE OUT AUG 4, 2016 9:37 AM AUG 4, 2016 8:38 AM JUL 27, 2016 9:33 AM DELIVERY NEEDED JUL 27, 2016 8:47 AM AUG 10, 2015 10:08 AM AUG 5, 2015 10:03 AM LOW TEMP WARNING AUG 4, 2016 9:38 AM AUG 10, 2015 10:11 AM SEP 19, 2013 4:21 PM I38200 AUG 4, 2016 11:48 AM I30200 AUG 4, 2016 11:48 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP AUG 4, 2016 9:29 AM SENSOR OUT ALARM AUG 4, 2016 9:15 AM FUEL ALARM AUG 4, 2016 9:14 AM FUEL ALARM 2 UNL 1 ANN AUG 4, 2016 9:29 AM SENSOR OUT ALARM AUG 4, 2016 9:18 AM FUEL ALARM JUL 27, 2016 9:26 AM FUEL ALARM 3 DSL STP AUG 4, 2016 9:29 AM SENSOR OUT ALARM AUG 4, 2016 9:16 AM FUEL ALARM JUL 27, 2016 9:09 AM FUEL ALARM 4 DSL ANN AUG 4, 2016 9:29 AM SENSOR OUT ALARM AUG 4, 2016 9:18 AM FUEL ALARM JUL 27, 2016 9:28 AM FUEL ALARM 6 PNL ANN AUG 4, 2016 9:29 AM SENSOR OUT ALARM AUG 4, 2016 9:19 AM FUEL ALARM JUL 27, 2016 9:28 AM FUEL ALARM 7 UNL 2 STP AUG 4, 2016 9:29 AM SENSOR OUT ALARM AUG 4, 2016 9:13 AM FUEL ALARM JUL 27, 2016 9:13 AM FUEL ALARM 8 UNL 2 ANN AUG 4, 2016 9:29 AM SENSOR OUT ALARM AUG 4, 2016 9:17 AM FUEL ALARM JUL 27, 2016 9:26 AM FUEL ALARM 9 DISP 1-2 AUG 4, 2016 9:29 AM SENSOR OUT ALARM AUG 4, 2016 9:21 AM FUEL ALARM JUL 27, 2016 9:15 AM FUEL ALARM 10 DISP 3-4 AUG 4, 2016 9:29 AM SENSOR OUT ALARM AUG 4, 2016 9:22 AM FUEL ALARM JUL 27, 2016 9:18 AM FUEL ALARM 11 DISP 5-6 AUG 4, 2016 9:29 AM SENSOR OUT ALARM AUG 4, 2016 9:22 AM FUEL ALARM AUG 4, 2016 9:22 AM FUEL ALARM 12 DISP 7-8 AUG 4, 2016 9:29 AM SENSOR OUT ALARM AUG 4, 2016 9:23 AM FUEL ALARM JUL 27, 2016 9:22 AM FUEL ALARM 13 TRANS SUMP NO AUG 4, 2016 9:29 AM SENSOR OUT ALARM AUG 4, 2016 9:24 AM FUEL ALARM JUL 27, 2016 9:23 AM FUEL ALARM 14 TRANS SUMP SO AUG 4, 2016 9:29 AM SENSOR OUT ALARM AUG 4, 2016 9:26 AM FUEL ALARM JUL 27, 2016 9:24 AM FUEL ALARM 15 PNL STP AUG 4, 2016 9:29 AM SENSOR OUT ALARM AUG 4, 2016 9:16 AM FUEL ALARM JUL 27, 2016 9:08 AM FUEL ALARM I31600 AUG 4, 2016 11:48 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 3-4 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 I40200 AUG 4, 2016 11:48 AM I40300 AUG 4, 2016 11:48 AM I34200 AUG 4, 2016 11:48 AM I34700 AUG 4, 2016 11:48 AM IV0100 AUG 4, 2016 11:48 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.03 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME : 99% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 16-07-28 10:51:02 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.35 16-03-28 10:50:56 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 16-03-27 10:50:39 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 16-03-17 10:50:23 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.78 16-03-10 10:50:19 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.56 16-03-03 10:50:25 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.41 16-02-25 10:51:11 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.36 16-02-18 10:50:38 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.53 16-02-11 10:51:11 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.31 16-02-04 10:51:41 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.34 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 15-12-16 10:01:58 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 15-12-16 10:01:58 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 15-12-15 10:01:56 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 12-08-18 10:02:49 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.70 11-08-25 10:02:34 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.05 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 16-08-04 10:50:09 READINESS ISD:PP EVR:PP ISD & EVR READY 16-08-04 09:29:20 READINESS ISD:PP EVR:NN EVR READINESS PENDING 16-08-04 09:29:20 ISD STARTUP 16-08-04 09:29:04 ISD SHUTDOWN 16-07-28 13:30:56 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 16-07-27 10:50:50 READINESS ISD:PP EVR:PP ISD & EVR READY 16-07-27 09:02:51 READINESS ISD:PP EVR:NN EVR READINESS PENDING 16-07-27 09:02:51 ISD STARTUP 16-07-27 09:01:47 ISD SHUTDOWN 16-06-10 10:51:04 READINESS ISD:PP EVR:PP ISD & EVR READY SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator forsubmittal to the local regulatory agency. 1.FACILITY INFORMATION Facility Name:Date of Testing: Facility Address: Facility Contact:Phone: Date Local Agency Was Notified of Testing : Name of Local Agency Inspector (if present during testing): 2.TESTING CONTRACTOR INFORMATION Company Name:Confidence UST Services, Inc. Technician Conducting Test: Credentials1:CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s):CSLB#804904 ICC# 3.SPILL BUCKET TESTING INFORMATION Test Method Used:Hydrostatic Vacuum Other Test Equipment Used:Lake TestEquipment Resolution:0.0625” Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1234 Bucket Installation Type: Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test: Test Start Time (TI): Initial Reading (RI): Test End Time (TF): Final Reading (RF): Test Duration (TF – TI): Change in Reading (RF -RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Comments –(include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician’s Signature:________________________________________________ Date:_________ 1 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. #3347Fastrip#26 08/04/2016 2698OswellStreet Bakersfield,CA93306 OmeroGarcia(661)393-7000 07/11/2016 Shane Gardener Cameron Mason 8111231-UT Regular#1 12.00" 12.00" 5min. 9:00 am 11.00" 10:00 am 11.00" 1hour 0.00" 0.0625" Regular#2 12.00" 12.00" 5min. 9:00 am 11.00" 10:00 am 11.00" 1hour 0.00" 0.0625"0.0625" Super 12.00" 12.00" 5min. 9:00 am 11.00" 10:00 am 11.00" 1hour 0.00" Diesel 12.00" 12.00" 5min. 9:00 am 11.00" 10:00 am 11.00" 1hour 0.00" 0.0625" 08/04/2016