Loading...
HomeMy WebLinkAboutFMC 2016MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of CaliforniaAuthority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A.General Information Facility Name:Bldg. No.: Site Address:City:Zip: Facility Contact Person: Contact Phone No.: Make/Model of Monitoring System:Date of Testing/Servicing: B.Inventory of Equipment Tested/Certified Check the appropriate boxes to indicate specific equipment inspected/serviced: Tank ID:Tank ID: In-Tank Gauging Probe.Model:In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model:Annular Space or Vault Sensor.Model: Piping Sump / Trench Sensor(s).Model:Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model:Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model:Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Electronic LineLeak Detector.Model: Tank Overfill / High-Level Sensor.Model:Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2).Other (specify equipment type and model in Section E on Page 2). Tank ID:Tank ID: In-Tank Gauging Probe.Model:In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model:Annular Space or Vault Sensor.Model: Piping Sump / TrenchSensor(s).Model:Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model:Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model:Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Electronic Line Leak Detector.Model: Tank Overfill / High-Level Sensor.Model:Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2).Other (specify equipment type and model in Section E on Page 2). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C.Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers’ guidelines. Attached to this Certification is information (e.g. manufacturers' checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report;(check all that apply):System set-up Alarm history report Technician Name (print):Signature: Certification No.:License. No.:804904 Testing Company Name:Confidence UST Services, Inc.Phone No.:(800)339-9930 Site Address:Date of Testing/Servicing: Page 1 of 3 #7785/Fastrip#32 3701MingAvenueBakersfield93309 OmeroGarcia (661)393-7000 Veeder-RootTLS-350 07/28/2016 12,000gal.Regular 847390-107 794380-303 794380-208 794380-208 FX1V 847390-107 12,000gal.Super 847390-107 794380-303 794380-208 794380-208 FX1V 847390-107 12,000gal.Diesel 847390-107 794380-303 794380-208 794380-208 FX1DV 847390-107 1-2 794380-208 3-4 794380-208 5-6 794380-208 794380-208 7-8 CameronMason B42599 3701MingAvenue Bakersfield,CA93309 07/28/2016 794380-208 794380-208 Monitoring System Certification D.Results of Testing/Servicing Software Version Installed: Complete the following checklist: Yes No*Isthe audible alarm operational? Yes No*Is the visual alarm operational? Yes No*Were all sensors visually inspected, functionally tested, and confirmed operational? Yes No*Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* N/A If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) operational? Yes No* N/A For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) Sump/Trench Sensors; Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection? Yes; No. Yes No* N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent oftank capacity does the alarm trigger? % Yes*NoWas any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes*NoWas liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) Product; Water. If yes, describe causes in Section E, below. Yes No*Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable Yes No*Is all monitoring equipment operational per manufacturer’s specifications? * In Section E below, describe how and when these deficiencies were or will be corrected. E.Comments: Page 2 of 3 329.02 90 Monitoring System Certification F.In-Tank Gauging / SIR Equipment: Check this box if tank gauging is used only for inventory control. Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: Yes No*Has all input wiring been inspected for proper entry and termination, including testing for ground faults? Yes No*Were all tank gauging probes visually inspected for damage and residue buildup? Yes No*Was accuracy of system product level readings tested? Yes No*Was accuracy of system water level readings tested? Yes No*Were all probes reinstalled properly? Yes No*Were all items on the equipment manufacturer’s maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. G.Line Leak Detectors (LLD):Check this box if LLDs are not installed. Complete the following checklist: Yes No* N/A For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? (Check all that apply)Simulated leak rate: 3 g.p.h.; 0.1 g.p.h ; 0.2 g.p.h. Yes No*Were all LLDs confirmed operational and accurate within regulatory requirements? Yes No*Was the testing apparatus properly calibrated? Yes No* N/A For mechanical LLDs, does the LLD restrict product flow if it detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? Yes No* N/A For electronic LLDs, have all accessible wiring connections been visually inspected? Yes No*Were all items on the equipment manufacturer’s maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. H.Comments: Page 3 of 3 Leak Detector Test Results Sheet Customer Address: Work Order: Site Address: Test Date: Site Contact: Phone: Technician: Phone: 800-339-9930 ICC No.: Product Type LLD Type Model Serial No. Check Valve Holding Pressure Bleed Off ML. Leak Rate Tested: Pass/Fail 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi Technician Name: Technician No.: Signature: Date: JamiesonHill P.O.Box82515 Bakersfield,CA93380-2515 36823 07/28/2016 8174721-UT Regular Mechanical FX1V CameronMason (661)393-7000OmeroGarcia Bakersfield,CA93309 3701MingAvenue #7785/Fastrip#32 21 PSI150 ml Pass FX1VMechanicalPremium 19 PSI250 ml Pass FX1DVMechanicalDiesel 16 PSI100 ml Pass CameronMason 8174721-UT 07/28/2016 Responses Received: 200 FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 JUL 28, 2016 8:47 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 8429 61.25 1.0 96.5 3571 2 PREMIUM 8836 63.94 0.9 96.1 3164 3 DIESEL 8636 62.61 0.8 98.9 3364 I90500 JUL 28, 2016 8:47 AM SOFTWARE REVISION LEVEL VERSION 329.02 SOFTWARE# 346329-100-C CREATED - 09.07.01.16.29 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I50500 JUL 28, 2016 8:47 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 JUL 28, 2016 8:47 AM SHIFT TIME 1 : 6:00 AM I50202 JUL 28, 2016 8:47 AM SHIFT TIME 2 : DISABLED I50203 JUL 28, 2016 8:47 AM SHIFT TIME 3 : DISABLED I50204 JUL 28, 2016 8:47 AM SHIFT TIME 4 : DISABLED I54600 JUL 28, 2016 8:47 AM TANK PER TST NEEDED WRN: DISABLED I54900 JUL 28, 2016 8:47 AM TANK ANN TST NEEDED WRN: DISABLED I55300 JUL 28, 2016 8:47 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 JUL 28, 2016 8:47 AM LINE PER TST NEEDED WRN: DISABLED I55900 JUL 28, 2016 8:47 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 JUL 28, 2016 8:47 AM PRINT TC VOLUMES ENABLED I50E00 JUL 28, 2016 8:47 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 JUL 28, 2016 8:47 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 JUL 28, 2016 8:47 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 JUL 28, 2016 8:47 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 JUL 28, 2016 8:47 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 1 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 JUL 28, 2016 8:47 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 JUL 28, 2016 8:47 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 JUL 28, 2016 8:47 AM TANK CHART SECURITY DISABLED I5BD00 JUL 28, 2016 8:47 AM CUSTOM ALARM LABELS DISABLED I56000 JUL 28, 2016 8:47 AM MASS/DENSITY DISABLED I88101 JUL 28, 2016 8:47 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 JUL 28, 2016 8:47 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 JUL 28, 2016 8:47 AM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88104 JUL 28, 2016 8:47 AM I88105 JUL 28, 2016 8:47 AM I88106 JUL 28, 2016 8:47 AM I52000 JUL 28, 2016 8:47 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE MAR 9, 2011 DISABLED 2 ON DATE MAR 9, 2011 DISABLED 3 ON DATE MAR 9, 2011 DISABLED 4 ON DATE MAR 9, 2011 DISABLED 5 ON DATE MAR 9, 2011 DISABLED 6 ON DATE MAR 9, 2011 DISABLED 7 ON DATE MAR 9, 2011 DISABLED 8 ON DATE MAR 9, 2011 DISABLED I60100 JUL 28, 2016 8:47 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 PREMIUM ON 3 DIESEL ON 4 OFF I60200 JUL 28, 2016 8:47 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 PREMIUM 3 DIESEL 4 I60300 JUL 28, 2016 8:47 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 PREMIUM 2 3 DIESEL 3 4 4 I60900 JUL 28, 2016 8:47 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 PREMIUM 0.000700 3 DIESEL 0.000450 4 0.000000 I60700 JUL 28, 2016 8:47 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 96.00 2 PREMIUM 96.00 3 DIESEL 96.00 4 0.00 I60A00 JUL 28, 2016 8:47 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 4 PTS 12000 2 PREMIUM 4 PTS 12000 3 DIESEL 4 PTS 12000 4 1 PT 0 I60400 JUL 28, 2016 8:47 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 12000 2 PREMIUM 12000 3 DIESEL 12000 4 0 I60500 JUL 28, 2016 8:47 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12000 9999 6355 2505 2 PREMIUM 12000 9999 6355 2505 3 DIESEL 12000 9999 6355 2505 4 0 0 0 0 I60600 JUL 28, 2016 8:47 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12000 0 0 0 0 9999 0 0 0 0 6355 0 0 0 0 2505 0 0 0 0 2 PREMIUM 12000 0 0 0 0 9999 0 0 0 0 6355 0 0 0 0 2505 0 0 0 0 3 DIESEL 12000 0 0 0 0 9999 0 0 0 0 6355 0 0 0 0 2505 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 JUL 28, 2016 8:47 AM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 PREMIUM NO 3 DIESEL NO 4 NO I62F00 JUL 28, 2016 8:47 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 4.0 INCHES 2 PREMIUM 4.0 INCHES 3 DIESEL 4.0 INCHES I62700 JUL 28, 2016 8:47 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 PREMIUM 2.0 3 DIESEL 2.0 9999FF1B I62400 JUL 28, 2016 8:47 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 PREMIUM 3.0 3 DIESEL 3.0 I62800 JUL 28, 2016 8:47 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 12000 2 PREMIUM 12000 3 DIESEL 12000 4 0 I62300 JUL 28, 2016 8:47 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 10800 2 PREMIUM 10800 3 DIESEL 10800 4 0 I62200 JUL 28, 2016 8:47 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 11400 2 PREMIUM 11400 3 DIESEL 11400 4 0 I62900 JUL 28, 2016 8:48 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1800 2 PREMIUM 1800 3 DIESEL 1800 4 0 I62100 JUL 28, 2016 8:48 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1200 2 PREMIUM 1200 3 DIESEL 1200 4 0 I62600 JUL 28, 2016 8:48 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 PREMIUM 99 3 DIESEL 99 4 99 I62500 JUL 28, 2016 8:48 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 PREMIUM 99 3 DIESEL 99 4 99 I60800 JUL 28, 2016 8:48 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 PREMIUM 3.00 3 DIESEL 3.00 4 0.00 I60B00 JUL 28, 2016 8:48 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 JUL 28, 2016 8:48 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 PREMIUM 0.00 3 DIESEL 0.00 4 0.00 I61200 JUL 28, 2016 8:48 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED NONE NONE 2 PREMIUM NONE NONE 3 DIESEL NONE NONE 4 NONE NONE I63600 JUL 28, 2016 8:48 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 PREMIUM 120 3 DIESEL 120 4 0 I62A00 JUL 28, 2016 8:48 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 PREMIUM 120 3 DIESEL 120 4 0 I62C00 JUL 28, 2016 8:48 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 PREMIUM STANDARD 3 DIESEL STANDARD 4 STANDARD I62D00 JUL 28, 2016 8:48 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 JUL 28, 2016 8:48 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 PREMIUM OFF OFF 3 DIESEL OFF OFF 4 OFF OFF I63000 JUL 28, 2016 8:48 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 OFF I63200 JUL 28, 2016 8:48 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 OFF I61000 JUL 28, 2016 8:48 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 1 2 PREMIUM 1 3 DIESEL 1 4 1 I63A00 JUL 28, 2016 8:48 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 PREMIUM 10.00% 3 DIESEL 10.00% 4 10.00% I61100 JUL 28, 2016 8:48 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JUL 1, 2009 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 JUL 28, 2016 8:48 AM CSLD PROBABLITY OF DETECTION I61400 JUL 28, 2016 8:48 AM CSLD CLIMATE FACTOR I61600 JUL 28, 2016 8:48 AM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 PREMIUM IMMEDIATE 3 DIESEL IMMEDIATE 4 IMMEDIATE I61A00 JUL 28, 2016 8:48 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED DISABLED 2 PREMIUM DISABLED 3 DIESEL DISABLED 4 DISABLED I61B00 JUL 28, 2016 8:48 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 JUL 28, 2016 8:48 AM CSLD REPORT ONLY I62B00 JUL 28, 2016 8:48 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED ??? 0, 0 2 PREMIUM ??? 0, 0 3 DIESEL ??? 0, 0 4 ??? 0, 0 I63300 JUL 28, 2016 8:48 AM LEAK TEST REPORT FORMAT: NORMAL I63400 JUL 28, 2016 8:48 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 PREMIUM 0 3 DIESEL 0 4 0 I63500 JUL 28, 2016 8:48 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 PREMIUM 1 3 DIESEL 1 4 1 I63900 JUL 28, 2016 8:48 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED END FACTOR: NONE 2 PREMIUM END FACTOR: NONE 3 DIESEL END FACTOR: NONE 4 END FACTOR: NONE I78000 JUL 28, 2016 8:48 AM I77700 JUL 28, 2016 8:48 AM I77800 JUL 28, 2016 8:48 AM I78C00 JUL 28, 2016 8:48 AM I78300 JUL 28, 2016 8:48 AM I78F00 JUL 28, 2016 8:48 AM I78700 JUL 28, 2016 8:48 AM I70200 JUL 28, 2016 8:48 AM LIQUID LABEL DEVICE LABEL 1 UNL STP 2 UNL FILL 3 UNL ANN 4 PNL STP 5 PNL FILL 6 PNL ANN 7 DSL STP 8 DSL FILL 9 DSL ANN 10 VENT BOX 11 DISP 1-2 12 DISP 3-4 13 DISP 5-6 14 DISP 7-8 15 16 I70300 JUL 28, 2016 8:48 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL STP TRI-STATE (SINGLE FLOAT) 2 UNL FILL TRI-STATE (SINGLE FLOAT) 3 UNL ANN DUAL POINT HYDROSTATIC 4 PNL STP TRI-STATE (SINGLE FLOAT) 5 PNL FILL TRI-STATE (SINGLE FLOAT) 6 PNL ANN DUAL POINT HYDROSTATIC 7 DSL STP TRI-STATE (SINGLE FLOAT) 8 DSL FILL TRI-STATE (SINGLE FLOAT) 9 DSL ANN DUAL POINT HYDROSTATIC 10 VENT BOX TRI-STATE (SINGLE FLOAT) 11 DISP 1-2 TRI-STATE (SINGLE FLOAT) 12 DISP 3-4 TRI-STATE (SINGLE FLOAT) 13 DISP 5-6 TRI-STATE (SINGLE FLOAT) 14 DISP 7-8 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 JUL 28, 2016 8:48 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL STP STP SUMP 2 UNL FILL PIPING SUMP 3 UNL ANN ANNULAR SPACE 4 PNL STP STP SUMP 5 PNL FILL PIPING SUMP 6 PNL ANN ANNULAR SPACE 7 DSL STP STP SUMP 8 DSL FILL PIPING SUMP 9 DSL ANN ANNULAR SPACE 10 VENT BOX PIPING SUMP 11 DISP 1-2 DISPENSER PAN 12 DISP 3-4 DISPENSER PAN 13 DISP 5-6 DISPENSER PAN 14 DISP 7-8 DISPENSER PAN 15 OTHER SENSORS 16 OTHER SENSORS I74200 JUL 28, 2016 8:48 AM I74300 JUL 28, 2016 8:48 AM I74400 JUL 28, 2016 8:48 AM I74700 JUL 28, 2016 8:48 AM I74800 JUL 28, 2016 8:48 AM I74900 JUL 28, 2016 8:48 AM I7BC00 JUL 28, 2016 8:48 AM I80200 JUL 28, 2016 8:48 AM I80300 JUL 28, 2016 8:48 AM I80400 JUL 28, 2016 8:48 AM I80700 JUL 28, 2016 8:48 AM RELAY LABEL DEVICE LABEL 1 UNLEADED 2 PREMIUM 3 DIESEL 4 OVERFILL I80900 JUL 28, 2016 8:48 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNLEADED NORMALLY OPEN 2 PREMIUM NORMALLY OPEN 3 DIESEL NORMALLY CLOSED 4 OVERFILL NORMALLY OPEN I80B00 JUL 28, 2016 8:48 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNLEADED 1 2 PREMIUM 2 3 DIESEL NONE 4 OVERFILL NONE I80A00 JUL 28, 2016 8:48 AM RELAY TYPE RELAY DESIGNATION TYPE 1 UNLEADED PUMP CONTROL OUTPUT 2 PREMIUM PUMP CONTROL OUTPUT 3 DIESEL STANDARD 4 OVERFILL STANDARD I80C00 JUL 28, 2016 8:48 AM I80800 JUL 28, 2016 8:48 AM RELAY SETUP REPORT R 1:UNLEADED TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 1:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 1:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:PREMIUM TYPE: PUMP CONTROL OUTPUT TANK #: 2 LIQUID SENSOR ALMS L 4:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 4:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 4:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DIESEL TYPE: STANDARD NORMALLY CLOSED TANK #: NONE LIQUID SENSOR ALMS L 7:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 7:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM R 4:OVERFILL TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM I79000 JUL 28, 2016 8:49 AM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 JUL 28, 2016 8:49 AM I72300 JUL 28, 2016 8:49 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 VP 1-2 VAPOR PRESSURE 02 FM 1-2 AIR FLOW METER 03 FM 3-4 AIR FLOW METER 04 FM 5-6 AIR FLOW METER 05 FM 7-8 AIR FLOW METER 06 UNKNOWN 07 UNKNOWN 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 JUL 28, 2016 8:49 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 JUL 28, 2016 8:49 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 JUL 28, 2016 8:49 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 VAPOR PROCESSOR TYPE NONE IV4700 JUL 28, 2016 8:49 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 JUL 28, 2016 8:49 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 ACCEPT HIGH ORVR: YES IV4A00 JUL 28, 2016 8:49 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 01 01 01 BLEND3 02 02 02 01 BLEND3 03 03 03 02 BLEND3 04 04 04 02 BLEND3 05 05 05 03 BLEND3 06 06 06 03 BLEND3 07 07 07 04 BLEND3 08 08 08 04 BLEND3 IV4B00 JUL 28, 2016 8:49 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 JUL 28, 2016 8:49 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 JUL 28, 2016 8:49 AM ISD VERSION: 01.02 Responses Received: I10200 JUL 28, 2016 8:49 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 508342 503750 2 4 PROBE / G.T. 163473 163117 3 INTERSTITIAL BD 201165 200800 4 INTERSTITIAL BD 202252 201856 5 UNUSED 9852520 9802357 6 UNUSED 9818980 9791858 7 UNUSED 9810432 9797076 8 UNUSED 9806239 9788690 9 STP SENSE BOARD 32990 32980 10 RELAY BOARD 14864 14873 11 UNUSED 9809143 9793514 12 UNUSED 9805114 9793725 13 UNUSED 9800513 9790789 14 UNUSED 9800451 9791190 15 UNUSED 9800615 9793662 16 UNUSED 9794766 9795056 COMM 1 ELEC DISP INT. 100821 100733 COMM 2 RS232 SERIAL BD 14966 14958 COMM 3 RS232 SERIAL BD 14864 14873 COMM 4 UNUSED 9808713 9796577 COMM 5 UNUSED 9804828 9795584 COMM 6 UNUSED 9800206 9794718 I90200 JUL 28, 2016 8:49 AM SOFTWARE REVISION LEVEL VERSION 329.02 SOFTWARE# 346329-100-C CREATED - 09.07.01.16.29 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 JUL 28, 2016 8:49 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK UNLEADED PROBE OUT CLEAR 7-28-16 8:35AM T 1 TANK UNLEADED PROBE OUT ALARM 7-28-16 8:35AM T 2 TANK PREMIUM PROBE OUT CLEAR 7-28-16 8:34AM T 2 TANK PREMIUM PROBE OUT ALARM 7-28-16 8:34AM T 3 TANK DIESEL PROBE OUT CLEAR 7-28-16 8:33AM T 3 TANK DIESEL PROBE OUT ALARM 7-28-16 8:33AM T 1 TANK UNLEADED OVERFILL ALARM CLEAR 7-21-16 4:05PM T 1 TANK UNLEADED OVERFILL ALARM ALARM 7-21-16 4:02PM T 3 TANK DIESEL PROBE OUT CLEAR 7-19-16 10:53AM T 3 TANK DIESEL PROBE OUT ALARM 7-19-16 10:53AM T 2 TANK PREMIUM PROBE OUT CLEAR 7-19-16 10:50AM T 2 TANK PREMIUM OVERFILL ALARM CLEAR 7-19-16 10:49AM T 2 TANK PREMIUM PROBE OUT ALARM 7-19-16 10:49AM T 2 TANK PREMIUM OVERFILL ALARM ALARM 7-19-16 10:49AM T 1 TANK UNLEADED PROBE OUT CLEAR 7-19-16 10:46AM T 1 TANK UNLEADED OVERFILL ALARM CLEAR 7-19-16 10:45AM T 1 TANK UNLEADED PROBE OUT ALARM 7-19-16 10:45AM T 1 TANK UNLEADED OVERFILL ALARM ALARM 7-19-16 10:45AM L 4 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 7-19-16 10:34AM L 3 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 7-19-16 10:34AM L 6 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 7-19-16 10:34AM L 2 PIPE UNL FILL SENSOR OUT ALARM CLEAR 7-19-16 10:34AM L 8 PIPE DSL FILL SENSOR OUT ALARM CLEAR 7-19-16 10:34AM L 7 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 7-19-16 10:34AM L 5 PIPE PNL FILL SENSOR OUT ALARM CLEAR 7-19-16 10:34AM L 1 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 7-19-16 10:34AM L10 PIPE VENT BOX SENSOR OUT ALARM CLEAR 7-19-16 10:34AM L14 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 7-19-16 10:34AM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 7-19-16 10:34AM L11 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 7-19-16 10:34AM L 9 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 7-19-16 10:34AM L13 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 7-19-16 10:34AM L 2 PIPE UNL FILL SENSOR OUT ALARM ALARM 7-19-16 10:34AM L 8 PIPE DSL FILL SENSOR OUT ALARM ALARM 7-19-16 10:34AM L 7 STP SUMP DSL STP SENSOR OUT ALARM ALARM 7-19-16 10:34AM L14 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 7-19-16 10:34AM L 6 ANNULAR PNL ANN SENSOR OUT ALARM ALARM 7-19-16 10:34AM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 7-19-16 10:34AM L11 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 7-19-16 10:34AM L 4 STP SUMP PNL STP SENSOR OUT ALARM ALARM 7-19-16 10:34AM L 3 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 7-19-16 10:34AM L 1 STP SUMP UNL STP SENSOR OUT ALARM ALARM 7-19-16 10:34AM L10 PIPE VENT BOX SENSOR OUT ALARM ALARM 7-19-16 10:34AM L13 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 7-19-16 10:34AM L 5 PIPE PNL FILL SENSOR OUT ALARM ALARM 7-19-16 10:34AM L 9 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 7-19-16 10:33AM L10 PIPE VENT BOX FUEL ALARM CLEAR 7-19-16 10:22AM L10 PIPE VENT BOX FUEL ALARM ALARM 7-19-16 10:21AM L13 DISP PAN DISP 5-6 FUEL ALARM CLEAR 7-19-16 10:19AM L13 DISP PAN DISP 5-6 FUEL ALARM ALARM 7-19-16 10:19AM I11200 JUL 28, 2016 8:49 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK PREMIUM LOW TEMP WARNING CLEAR 7-28-16 8:35AM T 2 TANK PREMIUM LOW TEMP WARNING ALARM 7-28-16 8:34AM OTHER ISD VAPOR LEAK WARN CLEAR 7-27-16 5:07PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-22-16 9:19PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-22-16 8:34PM OTHER ISD VAPOR LEAK WARN ALARM 7-21-16 10:01AM T 3 TANK DIESEL LOW TEMP WARNING CLEAR 7-19-16 10:55AM T 3 TANK DIESEL LOW TEMP WARNING ALARM 7-19-16 10:54AM T 3 TANK DIESEL HIGH PRODUCT ALARM CLEAR 7-19-16 10:52AM T 3 TANK DIESEL HIGH PRODUCT ALARM ALARM 7-19-16 10:52AM T 2 TANK PREMIUM LOW TEMP WARNING CLEAR 7-19-16 10:50AM T 2 TANK PREMIUM LOW TEMP WARNING ALARM 7-19-16 10:50AM T 2 TANK PREMIUM HIGH PRODUCT ALARM CLEAR 7-19-16 10:49AM T 2 TANK PREMIUM HIGH PRODUCT ALARM ALARM 7-19-16 10:49AM OTHER ISD VAPOR LEAK WARN CLEAR 7-15-16 1:52PM OTHER ISD VAPOR LEAK WARN ALARM 7-12-16 10:01AM h 8 OTHER FP8: BLEND3 GROSS COLLECT WARN CLEAR 6-28-16 4:49PM h 8 OTHER FP8: BLEND3 GROSS COLLECT WARN ALARM 6-28-16 10:01AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-17-16 7:46PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-17-16 5:25PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-16-16 6:41PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-16-16 6:34PM SYSTEM PRINTER ERROR CLEAR 6-15-16 10:16AM SYSTEM PAPER OUT CLEAR 6-15-16 10:16AM SYSTEM PRINTER ERROR ALARM 6-15-16 10:16AM SYSTEM PAPER OUT ALARM 6-15-16 10:16AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-11-16 12:02PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-11-16 11:43AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-07-16 4:48PM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 6-07-16 4:46PM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 6-07-16 4:40PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-07-16 2:10PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-06-16 4:30PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-06-16 3:45PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-05-16 4:12PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-05-16 2:14PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-03-16 6:06PM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 6-03-16 6:03PM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 6-03-16 5:47PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-03-16 3:40PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-03-16 4:40AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-03-16 1:42AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-02-16 5:46AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-02-16 4:35AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-02-16 2:19AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-01-16 10:12PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 5-29-16 2:53PM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 5-29-16 2:51PM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 5-29-16 1:14PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 5-29-16 10:24AM I20600 JUL 28, 2016 8:49 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM JUL 21, 2016 4:02 PM JUL 19, 2016 10:45 AM JUL 16, 2016 2:33 PM LOW PRODUCT ALARM JUN 17, 2016 6:50 PM JUN 7, 2016 3:35 PM JUN 5, 2016 3:46 PM SUDDEN LOSS ALARM JUL 19, 2016 9:27 AM JUL 29, 2015 10:09 AM JUL 22, 2014 9:32 AM HIGH PRODUCT ALARM JAN 19, 2016 3:20 PM DEC 4, 2015 4:19 PM OCT 15, 2015 11:07 AM INVALID FUEL LEVEL JUN 7, 2016 4:40 PM JUN 3, 2016 5:47 PM MAY 29, 2016 1:14 PM PROBE OUT JUL 28, 2016 8:35 AM JUL 19, 2016 10:45 AM JUL 19, 2016 9:27 AM DELIVERY NEEDED JUL 22, 2016 8:34 PM JUN 17, 2016 5:25 PM JUN 16, 2016 6:34 PM MAX PRODUCT ALARM OCT 15, 2015 11:08 AM SEP 4, 2015 6:29 PM MAY 31, 2015 9:26 PM LOW TEMP WARNING JUL 29, 2015 10:12 AM JUL 31, 2014 9:52 AM SEP 12, 2012 9:49 AM TANK 2 PREMIUM OVERFILL ALARM JUL 19, 2016 10:49 AM DEC 22, 2015 4:53 AM DEC 20, 2015 11:56 AM LOW PRODUCT ALARM JAN 30, 2016 1:22 PM OCT 24, 2015 8:29 PM JUL 29, 2015 10:04 AM SUDDEN LOSS ALARM JUL 19, 2016 9:32 AM JUL 29, 2015 10:04 AM JUL 22, 2015 10:22 AM HIGH PRODUCT ALARM JUL 19, 2016 10:49 AM JUL 29, 2015 10:06 AM JUL 22, 2015 10:23 AM INVALID FUEL LEVEL JAN 30, 2016 4:42 PM OCT 24, 2015 8:59 PM JUL 22, 2015 10:24 AM PROBE OUT JUL 28, 2016 8:34 AM JUL 19, 2016 10:49 AM JUL 19, 2016 9:32 AM DELIVERY NEEDED MAY 5, 2016 3:23 PM APR 22, 2016 2:15 PM JAN 30, 2016 5:24 AM LOW TEMP WARNING JUL 28, 2016 8:34 AM JUL 19, 2016 10:50 AM JUL 31, 2014 9:59 AM TANK 3 DIESEL OVERFILL ALARM JUL 29, 2015 10:01 AM AUG 1, 2012 9:40 AM HIGH PRODUCT ALARM JUL 19, 2016 10:52 AM JUL 29, 2015 10:01 AM JUL 22, 2015 10:26 AM INVALID FUEL LEVEL JUL 31, 2014 9:46 AM JUL 22, 2014 10:34 AM AUG 1, 2013 1:33 PM PROBE OUT JUL 28, 2016 8:33 AM JUL 19, 2016 10:53 AM JUL 19, 2016 9:33 AM DELIVERY NEEDED MAY 19, 2016 10:19 AM MAY 11, 2016 12:47 PM MAY 4, 2016 6:07 AM LOW TEMP WARNING JUL 19, 2016 10:54 AM JUL 29, 2015 10:02 AM JUL 22, 2015 10:28 AM I38200 JUL 28, 2016 8:49 AM I30200 JUL 28, 2016 8:49 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL STP JUL 19, 2016 10:34 AM SENSOR OUT ALARM JUL 19, 2016 9:46 AM FUEL ALARM FEB 28, 2016 6:08 AM FUEL ALARM 2 UNL FILL JUL 19, 2016 10:34 AM SENSOR OUT ALARM JUL 19, 2016 9:48 AM FUEL ALARM JUL 29, 2015 10:17 AM SENSOR OUT ALARM 3 UNL ANN JUL 19, 2016 10:34 AM SENSOR OUT ALARM JUL 19, 2016 9:50 AM LOW LIQUID ALARM JUL 19, 2016 9:49 AM HIGH LIQUID ALARM 4 PNL STP JUL 19, 2016 10:34 AM SENSOR OUT ALARM JUL 19, 2016 9:52 AM FUEL ALARM JUN 10, 2016 10:05 AM FUEL ALARM 5 PNL FILL JUL 19, 2016 10:34 AM SENSOR OUT ALARM JUL 19, 2016 9:53 AM FUEL ALARM JUL 29, 2015 10:17 AM SENSOR OUT ALARM 6 PNL ANN JUL 19, 2016 10:34 AM SENSOR OUT ALARM JUL 19, 2016 10:02 AM HIGH LIQUID ALARM JUL 19, 2016 10:01 AM LOW LIQUID ALARM 7 DSL STP JUL 19, 2016 10:34 AM SENSOR OUT ALARM JUL 19, 2016 10:03 AM FUEL ALARM JUL 29, 2015 10:17 AM SENSOR OUT ALARM 8 DSL FILL JUL 19, 2016 10:34 AM SENSOR OUT ALARM JUL 19, 2016 10:06 AM FUEL ALARM APR 24, 2016 9:02 PM FUEL ALARM 9 DSL ANN JUL 19, 2016 10:33 AM SENSOR OUT ALARM JUL 19, 2016 10:08 AM LOW LIQUID ALARM JUL 19, 2016 10:08 AM HIGH LIQUID ALARM 10 VENT BOX JUL 19, 2016 10:34 AM SENSOR OUT ALARM JUL 19, 2016 10:21 AM FUEL ALARM JUL 29, 2015 10:17 AM SENSOR OUT ALARM 11 DISP 1-2 JUL 19, 2016 10:34 AM SENSOR OUT ALARM JUL 19, 2016 10:16 AM FUEL ALARM JUL 29, 2015 10:17 AM SENSOR OUT ALARM 12 DISP 3-4 JUL 19, 2016 10:34 AM SENSOR OUT ALARM JUL 19, 2016 10:18 AM FUEL ALARM APR 26, 2016 10:27 AM FUEL ALARM 13 DISP 5-6 JUL 19, 2016 10:34 AM SENSOR OUT ALARM JUL 19, 2016 10:19 AM FUEL ALARM JUL 29, 2015 10:17 AM SENSOR OUT ALARM 14 DISP 7-8 JUL 19, 2016 10:34 AM SENSOR OUT ALARM JUL 19, 2016 10:19 AM FUEL ALARM JUL 29, 2015 10:17 AM SENSOR OUT ALARM I31600 JUL 28, 2016 8:49 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 VP 1-2 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 JUL 11, 2012 5:01 PM COMMUNICATION ALARM JAN 11, 2012 6:17 PM COMMUNICATION ALARM AUG 17, 2010 10:25 AM COMMUNICATION ALARM I40200 JUL 28, 2016 8:49 AM I40300 JUL 28, 2016 8:49 AM I34200 JUL 28, 2016 8:49 AM I34700 JUL 28, 2016 8:49 AM IV0100 JUL 28, 2016 8:49 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.02 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :WARN EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :WARN ISD MONITOR UP-TIME :100% STAGE I TRANSFERS: 0 of 0 NOTEST EVR/ISD PASS TIME : 0% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 16-07-27 10:01:40 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-26 10:01:47 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-25 10:01:46 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-24 10:01:16 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-23 10:01:15 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-22 10:01:13 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-21 10:01:09 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-15 10:01:24 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-14 10:01:18 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-13 10:01:22 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.15 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 13-08-20 10:01:35 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 BLKD 13-03-15 10:02:04 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 BLKD 11-09-08 10:02:27 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 11-06-28 10:02:43 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 11-06-28 10:02:43 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 11-06-27 10:02:45 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 10-11-01 10:01:09 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 10-11-01 10:01:09 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 16-07-27 17:07:44 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED 16-07-20 10:01:31 READINESS ISD:PP EVR:PP ISD & EVR READY 16-07-19 10:32:31 READINESS ISD:PP EVR:NN EVR READINESS PENDING 16-07-19 10:32:31 ISD STARTUP 16-07-19 10:32:03 ISD SHUTDOWN 16-07-15 13:52:15 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED 16-06-28 16:49:52 COLLECTION TEST HH08 GRADE TEST MANUALLY CLEARED 16-05-12 10:01:52 READINESS ISD:PP EVR:PP ISD & EVR READY 16-05-12 06:03:24 READINESS ISD:PP EVR:NN EVR READINESS PENDING 16-05-12 06:03:24 ISD STARTUP Responses Received: I10200 JUL 28, 2016 11:27 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 508342 503424 2 4 PROBE / G.T. 163473 163180 3 INTERSTITIAL BD 201165 200994 4 INTERSTITIAL BD 202252 201962 5 UNUSED 9852520 9807111 6 UNUSED 9818980 9802253 7 UNUSED 9810432 9810407 8 UNUSED 9806239 9800541 9 STP SENSE BOARD 32990 33023 10 RELAY BOARD 14864 14894 11 UNUSED 9809143 9807415 12 UNUSED 9805114 9808915 13 UNUSED 9800513 9802620 14 UNUSED 9800451 9800718 15 UNUSED 9800615 9801859 16 UNUSED 9794766 9801247 COMM 1 ELEC DISP INT. 100821 100819 COMM 2 RS232 SERIAL BD 14966 14958 COMM 3 RS232 SERIAL BD 14864 14894 COMM 4 UNUSED 9808713 9807711 COMM 5 UNUSED 9804828 9801247 COMM 6 UNUSED 9800206 9802049 I90200 JUL 28, 2016 11:27 AM SOFTWARE REVISION LEVEL VERSION 329.02 SOFTWARE# 346329-100-C CREATED - 09.07.01.16.29 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 JUL 28, 2016 11:27 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 2 PIPE UNL FILL SENSOR OUT ALARM CLEAR 7-28-16 9:51AM L 8 PIPE DSL FILL SENSOR OUT ALARM CLEAR 7-28-16 9:51AM L 7 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 7-28-16 9:51AM L 6 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 7-28-16 9:51AM L 4 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 7-28-16 9:51AM L 3 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 7-28-16 9:51AM L 1 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 7-28-16 9:51AM L 5 PIPE PNL FILL SENSOR OUT ALARM CLEAR 7-28-16 9:51AM L14 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 7-28-16 9:51AM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 7-28-16 9:51AM L11 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 7-28-16 9:51AM L10 PIPE VENT BOX SENSOR OUT ALARM CLEAR 7-28-16 9:51AM L13 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 7-28-16 9:51AM L 9 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 7-28-16 9:51AM L14 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 7-28-16 9:51AM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 7-28-16 9:51AM L11 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 7-28-16 9:51AM L10 PIPE VENT BOX SENSOR OUT ALARM ALARM 7-28-16 9:51AM L 2 PIPE UNL FILL SENSOR OUT ALARM ALARM 7-28-16 9:51AM L 8 PIPE DSL FILL SENSOR OUT ALARM ALARM 7-28-16 9:51AM L 7 STP SUMP DSL STP SENSOR OUT ALARM ALARM 7-28-16 9:51AM L13 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 7-28-16 9:51AM L 6 ANNULAR PNL ANN SENSOR OUT ALARM ALARM 7-28-16 9:51AM L 9 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 7-28-16 9:51AM L 4 STP SUMP PNL STP SENSOR OUT ALARM ALARM 7-28-16 9:51AM L 3 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 7-28-16 9:51AM L 1 STP SUMP UNL STP SENSOR OUT ALARM ALARM 7-28-16 9:51AM L 5 PIPE PNL FILL SENSOR OUT ALARM ALARM 7-28-16 9:51AM T 3 TANK DIESEL PROBE OUT CLEAR 7-28-16 9:44AM T 3 TANK DIESEL OVERFILL ALARM CLEAR 7-28-16 9:43AM T 3 TANK DIESEL PROBE OUT ALARM 7-28-16 9:43AM T 3 TANK DIESEL OVERFILL ALARM ALARM 7-28-16 9:42AM T 2 TANK PREMIUM PROBE OUT CLEAR 7-28-16 9:39AM T 2 TANK PREMIUM OVERFILL ALARM CLEAR 7-28-16 9:38AM T 2 TANK PREMIUM PROBE OUT ALARM 7-28-16 9:38AM T 2 TANK PREMIUM OVERFILL ALARM ALARM 7-28-16 9:38AM T 1 TANK UNLEADED PROBE OUT CLEAR 7-28-16 9:36AM T 1 TANK UNLEADED OVERFILL ALARM CLEAR 7-28-16 9:35AM T 1 TANK UNLEADED PROBE OUT ALARM 7-28-16 9:35AM T 1 TANK UNLEADED OVERFILL ALARM ALARM 7-28-16 9:34AM L10 PIPE VENT BOX FUEL ALARM CLEAR 7-28-16 9:32AM L10 PIPE VENT BOX FUEL ALARM ALARM 7-28-16 9:31AM L13 DISP PAN DISP 5-6 FUEL ALARM CLEAR 7-28-16 9:30AM L13 DISP PAN DISP 5-6 FUEL ALARM ALARM 7-28-16 9:30AM L12 DISP PAN DISP 3-4 FUEL ALARM CLEAR 7-28-16 9:29AM L12 DISP PAN DISP 3-4 FUEL ALARM ALARM 7-28-16 9:28AM L11 DISP PAN DISP 1-2 FUEL ALARM CLEAR 7-28-16 9:28AM L11 DISP PAN DISP 1-2 FUEL ALARM ALARM 7-28-16 9:27AM L 8 PIPE DSL FILL FUEL ALARM CLEAR 7-28-16 9:27AM L 8 PIPE DSL FILL FUEL ALARM ALARM 7-28-16 9:27AM I11200 JUL 28, 2016 11:27 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK PREMIUM LOW TEMP WARNING CLEAR 7-28-16 9:40AM T 2 TANK PREMIUM LOW TEMP WARNING ALARM 7-28-16 9:39AM T 2 TANK PREMIUM HIGH PRODUCT ALARM CLEAR 7-28-16 9:39AM T 2 TANK PREMIUM HIGH PRODUCT ALARM ALARM 7-28-16 9:37AM T 1 TANK UNLEADED LOW TEMP WARNING CLEAR 7-28-16 9:36AM T 1 TANK UNLEADED LOW TEMP WARNING ALARM 7-28-16 9:36AM T 2 TANK PREMIUM LOW TEMP WARNING CLEAR 7-28-16 8:35AM T 2 TANK PREMIUM LOW TEMP WARNING ALARM 7-28-16 8:34AM OTHER ISD VAPOR LEAK WARN CLEAR 7-27-16 5:07PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-22-16 9:19PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-22-16 8:34PM OTHER ISD VAPOR LEAK WARN ALARM 7-21-16 10:01AM T 3 TANK DIESEL LOW TEMP WARNING CLEAR 7-19-16 10:55AM T 3 TANK DIESEL LOW TEMP WARNING ALARM 7-19-16 10:54AM T 3 TANK DIESEL HIGH PRODUCT ALARM CLEAR 7-19-16 10:52AM T 3 TANK DIESEL HIGH PRODUCT ALARM ALARM 7-19-16 10:52AM T 2 TANK PREMIUM LOW TEMP WARNING CLEAR 7-19-16 10:50AM T 2 TANK PREMIUM LOW TEMP WARNING ALARM 7-19-16 10:50AM T 2 TANK PREMIUM HIGH PRODUCT ALARM CLEAR 7-19-16 10:49AM T 2 TANK PREMIUM HIGH PRODUCT ALARM ALARM 7-19-16 10:49AM OTHER ISD VAPOR LEAK WARN CLEAR 7-15-16 1:52PM OTHER ISD VAPOR LEAK WARN ALARM 7-12-16 10:01AM h 8 OTHER FP8: BLEND3 GROSS COLLECT WARN CLEAR 6-28-16 4:49PM h 8 OTHER FP8: BLEND3 GROSS COLLECT WARN ALARM 6-28-16 10:01AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-17-16 7:46PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-17-16 5:25PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-16-16 6:41PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-16-16 6:34PM SYSTEM PRINTER ERROR CLEAR 6-15-16 10:16AM SYSTEM PAPER OUT CLEAR 6-15-16 10:16AM SYSTEM PRINTER ERROR ALARM 6-15-16 10:16AM SYSTEM PAPER OUT ALARM 6-15-16 10:16AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-11-16 12:02PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-11-16 11:43AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-07-16 4:48PM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 6-07-16 4:46PM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 6-07-16 4:40PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-07-16 2:10PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-06-16 4:30PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-06-16 3:45PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-05-16 4:12PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-05-16 2:14PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-03-16 6:06PM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 6-03-16 6:03PM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 6-03-16 5:47PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-03-16 3:40PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-03-16 4:40AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-03-16 1:42AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-02-16 5:46AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-02-16 4:35AM I20600 JUL 28, 2016 11:27 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM JUL 28, 2016 9:34 AM JUL 21, 2016 4:02 PM JUL 19, 2016 10:45 AM LOW PRODUCT ALARM JUN 17, 2016 6:50 PM JUN 7, 2016 3:35 PM JUN 5, 2016 3:46 PM SUDDEN LOSS ALARM JUL 19, 2016 9:27 AM JUL 29, 2015 10:09 AM JUL 22, 2014 9:32 AM HIGH PRODUCT ALARM JAN 19, 2016 3:20 PM DEC 4, 2015 4:19 PM OCT 15, 2015 11:07 AM INVALID FUEL LEVEL JUN 7, 2016 4:40 PM JUN 3, 2016 5:47 PM MAY 29, 2016 1:14 PM PROBE OUT JUL 28, 2016 9:35 AM JUL 28, 2016 8:35 AM JUL 19, 2016 10:45 AM DELIVERY NEEDED JUL 22, 2016 8:34 PM JUN 17, 2016 5:25 PM JUN 16, 2016 6:34 PM MAX PRODUCT ALARM OCT 15, 2015 11:08 AM SEP 4, 2015 6:29 PM MAY 31, 2015 9:26 PM LOW TEMP WARNING JUL 28, 2016 9:36 AM JUL 29, 2015 10:12 AM JUL 31, 2014 9:52 AM TANK 2 PREMIUM OVERFILL ALARM JUL 28, 2016 9:38 AM JUL 19, 2016 10:49 AM DEC 22, 2015 4:53 AM LOW PRODUCT ALARM JAN 30, 2016 1:22 PM OCT 24, 2015 8:29 PM JUL 29, 2015 10:04 AM SUDDEN LOSS ALARM JUL 19, 2016 9:32 AM JUL 29, 2015 10:04 AM JUL 22, 2015 10:22 AM HIGH PRODUCT ALARM JUL 28, 2016 9:37 AM JUL 19, 2016 10:49 AM JUL 29, 2015 10:06 AM INVALID FUEL LEVEL JAN 30, 2016 4:42 PM OCT 24, 2015 8:59 PM JUL 22, 2015 10:24 AM PROBE OUT JUL 28, 2016 9:38 AM JUL 28, 2016 8:34 AM JUL 19, 2016 10:49 AM DELIVERY NEEDED MAY 5, 2016 3:23 PM APR 22, 2016 2:15 PM JAN 30, 2016 5:24 AM LOW TEMP WARNING JUL 28, 2016 9:39 AM JUL 28, 2016 8:34 AM JUL 19, 2016 10:50 AM TANK 3 DIESEL OVERFILL ALARM JUL 28, 2016 9:42 AM JUL 29, 2015 10:01 AM AUG 1, 2012 9:40 AM HIGH PRODUCT ALARM JUL 19, 2016 10:52 AM JUL 29, 2015 10:01 AM JUL 22, 2015 10:26 AM INVALID FUEL LEVEL JUL 31, 2014 9:46 AM JUL 22, 2014 10:34 AM AUG 1, 2013 1:33 PM PROBE OUT JUL 28, 2016 9:43 AM JUL 28, 2016 8:33 AM JUL 19, 2016 10:53 AM DELIVERY NEEDED MAY 19, 2016 10:19 AM MAY 11, 2016 12:47 PM MAY 4, 2016 6:07 AM LOW TEMP WARNING JUL 19, 2016 10:54 AM JUL 29, 2015 10:02 AM JUL 22, 2015 10:28 AM I38200 JUL 28, 2016 11:27 AM I30200 JUL 28, 2016 11:27 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL STP JUL 28, 2016 9:51 AM SENSOR OUT ALARM JUL 28, 2016 9:18 AM FUEL ALARM JUL 19, 2016 10:34 AM SENSOR OUT ALARM 2 UNL FILL JUL 28, 2016 9:51 AM SENSOR OUT ALARM JUL 28, 2016 9:25 AM FUEL ALARM JUL 19, 2016 10:34 AM SENSOR OUT ALARM 3 UNL ANN JUL 28, 2016 9:51 AM SENSOR OUT ALARM JUL 28, 2016 9:22 AM HIGH LIQUID ALARM JUL 28, 2016 9:21 AM LOW LIQUID ALARM 4 PNL STP JUL 28, 2016 9:51 AM SENSOR OUT ALARM JUL 28, 2016 9:19 AM FUEL ALARM JUL 19, 2016 10:34 AM SENSOR OUT ALARM 5 PNL FILL JUL 28, 2016 9:51 AM SENSOR OUT ALARM JUL 28, 2016 9:26 AM FUEL ALARM JUL 19, 2016 10:34 AM SENSOR OUT ALARM 6 PNL ANN JUL 28, 2016 9:51 AM SENSOR OUT ALARM JUL 28, 2016 9:23 AM LOW LIQUID ALARM JUL 28, 2016 9:22 AM HIGH LIQUID ALARM 7 DSL STP JUL 28, 2016 9:51 AM SENSOR OUT ALARM JUL 28, 2016 9:20 AM FUEL ALARM JUL 19, 2016 10:34 AM SENSOR OUT ALARM 8 DSL FILL JUL 28, 2016 9:51 AM SENSOR OUT ALARM JUL 28, 2016 9:27 AM FUEL ALARM JUL 19, 2016 10:34 AM SENSOR OUT ALARM 9 DSL ANN JUL 28, 2016 9:51 AM SENSOR OUT ALARM JUL 28, 2016 9:24 AM LOW LIQUID ALARM JUL 28, 2016 9:24 AM HIGH LIQUID ALARM 10 VENT BOX JUL 28, 2016 9:51 AM SENSOR OUT ALARM JUL 28, 2016 9:31 AM FUEL ALARM JUL 19, 2016 10:34 AM SENSOR OUT ALARM 11 DISP 1-2 JUL 28, 2016 9:51 AM SENSOR OUT ALARM JUL 28, 2016 9:27 AM FUEL ALARM JUL 19, 2016 10:34 AM SENSOR OUT ALARM 12 DISP 3-4 JUL 28, 2016 9:51 AM SENSOR OUT ALARM JUL 28, 2016 9:28 AM FUEL ALARM JUL 19, 2016 10:34 AM SENSOR OUT ALARM 13 DISP 5-6 JUL 28, 2016 9:51 AM SENSOR OUT ALARM JUL 28, 2016 9:30 AM FUEL ALARM JUL 19, 2016 10:34 AM SENSOR OUT ALARM 14 DISP 7-8 JUL 28, 2016 9:51 AM SENSOR OUT ALARM JUL 19, 2016 10:34 AM SENSOR OUT ALARM JUL 19, 2016 10:19 AM FUEL ALARM I31600 JUL 28, 2016 11:27 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 VP 1-2 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 JUL 11, 2012 5:01 PM COMMUNICATION ALARM JAN 11, 2012 6:17 PM COMMUNICATION ALARM AUG 17, 2010 10:25 AM COMMUNICATION ALARM I40200 JUL 28, 2016 11:27 AM I40300 JUL 28, 2016 11:27 AM I34200 JUL 28, 2016 11:27 AM I34700 JUL 28, 2016 11:27 AM IV0100 JUL 28, 2016 11:27 AM FASTRIP 785 3701 MING AVE BAKERSFIELD 93309 661-397-3699 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.02 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME : 99% STAGE I TRANSFERS: 5 of 5 PASS EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 16-07-27 10:01:40 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-26 10:01:47 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-25 10:01:46 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-24 10:01:16 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-23 10:01:15 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-22 10:01:13 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-21 10:01:09 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-15 10:01:24 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-14 10:01:18 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 16-07-13 10:01:22 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.15 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 13-08-20 10:01:35 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 BLKD 13-03-15 10:02:04 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 BLKD 11-09-08 10:02:27 VAPOR CONTAINMENT LEAKAGE GROSS FAIL 11-06-28 10:02:43 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 11-06-28 10:02:43 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 11-06-27 10:02:45 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 10-11-01 10:01:09 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 10-11-01 10:01:09 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 16-07-28 10:01:09 READINESS ISD:PP EVR:PP ISD & EVR READY 16-07-28 09:50:57 READINESS ISD:PP EVR:NN EVR READINESS PENDING 16-07-28 09:50:57 ISD STARTUP 16-07-28 09:50:36 ISD SHUTDOWN 16-07-27 17:07:44 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED 16-07-20 10:01:31 READINESS ISD:PP EVR:PP ISD & EVR READY 16-07-19 10:32:31 READINESS ISD:PP EVR:NN EVR READINESS PENDING 16-07-19 10:32:31 ISD STARTUP 16-07-19 10:32:03 ISD SHUTDOWN 16-07-15 13:52:15 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator forsubmittal to the local regulatory agency. 1.FACILITY INFORMATION Facility Name:Date of Testing: Facility Address: Facility Contact:Phone: Date Local Agency Was Notified of Testing : Name of Local Agency Inspector (if present during testing): 2.TESTING CONTRACTOR INFORMATION Company Name:Confidence UST Services, Inc. Technician Conducting Test: Credentials1:CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s):CSLB#804904 ICC# 3.SPILL BUCKET TESTING INFORMATION Test Method Used:Hydrostatic Vacuum Other Test Equipment Used:Lake TestEquipment Resolution:0.0625” Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1234 Bucket Installation Type: Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test: Test Start Time (TI): Initial Reading (RI): Test End Time (TF): Final Reading (RF): Test Duration (TF – TI): Change in Reading (RF -RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Comments –(include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician’s Signature:________________________________________________ Date:_________ 1 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. #7785/Fastrip#32 07/28/2016 3701MingAvenue Bakersfield,CA93309 OmeroGarcia(661)393-7000 06/14/2016 Kris Karns CameronMason 8174721-UT Regular 12.00" 12.75" 5min. 9:00 am 11.00" 10:00 am 11.00" 1hour 0.00" 0.0625" Super 12.00" 13.00" 5min. 9:00 am 11.00" 10:00 am 11.00" 1hour 0.00" 0.0625"0.0625" Diesel 12.00" 12.50" 5min. 9:00 am 11.00" 10:00 am 11.00" 1hour 0.00" 07/28/2016