Loading...
HomeMy WebLinkAboutFMC 2015 2/21/07 1 Appendix VI (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.waterboards.ca.gov.) MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of California Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A. General Information Facility Name: _____Avo’s Shell _________________________________________________ Bldg. No.:___________________ Site Address: __5700 Auburn St. ____ _____________________ City: _Bakersfield ____________ Zip: ____________________ Facility Contact Person: ___________________________________________ Contact Phone No.: (_______)__________________________ Make/Model of Monitoring System: Veeder-Root TLS-350________________________ Date of Testing/Servicing: _3_/_12_/_2015_____ B. Inventory of Equipment Tested/Certified Check the appropriate boxes to indicate specific equipment inspected/serviced: Tank ID: _ 87 UL__ _____________________________ X In-Tank Gauging Probe. Model: __Mag.______________ X Annular Space or Vault Sensor. Model: 794380-301 __ __ _ X Piping Sump / Trench Sensor(s). Model: 794380-208 __ __ _ X Fill Sump Sensor(s). Model: 794380-208 __ __ _ X Mechanical Line Leak Detector. Model: _FX1V ___ Electronic Line Leak Detector. Model: ____________________ Tank Overfill / High-Level Sensor. Model: ____________________ Other (specify equipment type and model in Section E on Page 2). Tank ID: _ Diesel _ _____________________________ X In-Tank Gauging Probe. Model: __Mag.______________ X Annular Space or Vault Sensor. Model: 794380-301 __ __ _ X Piping Sump / Trench Sensor(s). Model: 794380-208 __ __ _ X Fill Sump Sensor(s). Model: 794380-208 __ __ _ X Mechanical Line Leak Detector. Model: _FX1DV __ Electronic Line Leak Detector. Model: ____________________ Tank Overfill / High-Level Sensor. Model: ____________________ Other (specify equipment type and model in Section E on Page 2). Tank ID: _ 87 UL_ _____________________________ X In-Tank Gauging Probe. Model: __Mag.______________ X Annular Space or Vault Sensor. Model: 794380-301 __ __ _ X Piping Sump / Trench Sensor(s). Model: 794380-208 __ __ _ X Fill Sump Sensor(s). Model: 794380-208 __ __ _ X Mechanical Line Leak Detector. Model: _FX1V ___ Electronic Line Leak Detector. Model: ____________________ Tank Overfill / High-Level Sensor. Model: ____________________ Other (specify equipment type and model in Section E on Page 2). Tank ID: _ __ ____________________________ In-Tank Gauging Probe. Model: ____________________ Annular Space or Vault Sensor. Model: ____________________ Piping Sump / Trench Sensor(s). Model: ____________________ Fill Sump Sensor(s). Model: ____________________ Mechanical Line Leak Detector. Model: ____________________ Electronic Line Leak Detector. Model: ____________________ Tank Overfill / High-Level Sensor. Model: ____________________ Other (specify equipment type and model in Section E on Page 2). Dispenser ID: _1-2 __________________________________ X Dispenser Containment Sensor(s). Model: 794380-208 __ __ _ X Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: _7-8 __________________________________ X Dispenser Containment Sensor(s). Model: 794380-208 __ __ _ X Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: _3-4 __________________________________ X Dispenser Containment Sensor(s). Model: 794380-208 __ __ _ X Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: _9-10 _________________________________ X Dispenser Containment Sensor(s). Model: 794380-208 __ __ _ X Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: _5-6 __________________________________ X Dispenser Containment Sensor(s). Model: 794380-208 __ __ _ X Shear Valve(s). Dispenser ID: _11-12 ________________________________ X Dispenser Containment Sensor(s). Model: 794380-208 __ __ _ X Shear Valve(s). Dispenser Containment Float(s) and Chain(s). *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers’ guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): X System set-up X Alarm history report Technician Name (print): _Bruce W. Hinsley___________________ Signature: __________________________________________________ Certification No.: _223613761 _____________________________ License. No.: _971259 C61/D40______________________________ Testing Company Name: _Advanced Compliance_______________________ Phone No.:(661) 706-4321______________________ Testing Company Address: _3704 Littlefalls Ct. Bakersfield, Ca. 93312______________________ Date of Testing/Servicing: _3_/_12_/_2015_____ Monitoring System Certification Page 1 of 4 12/07 2/21/07 2 D. Results of Testing/Servicing Software Version Installed: _327.04______________________________ Complete the following checklist: X Yes No* Is the audible alarm operational? X Yes No* Is the visual alarm operational? X Yes No* Were all sensors visually inspected, functionally tested, and confirmed operational? X Yes No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* X N/A If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? X Yes No* N/A For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) X Sump/Trench Sensors; X Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection? X Yes No* X N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? ________% Yes* X No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes* X No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) yes, describe causes in Section E, below. X Yes No* Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable X Yes No* Is all monitoring equipment operational per manufacturer’s specifications? * In Section E below, describe how and when these deficiencies were or will be corrected. E. Comments: ___________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ _________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ _________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ Monitoring System Certification Page 2 of 4 12/07 2/21/07 3 F. In-Tank Gauging / SIR Equipment: X Check this box if tank gauging is used only for inventory control. Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: Yes No* Has all input wiring been inspected for proper entry and termination, including testing for ground faults? Yes No* Were all tank gauging probes visually inspected for damage and residue buildup? Yes No* Was accuracy of system product level readings tested? Yes No* Was accuracy of system water level readings tested? Yes No* Were all probes reinstalled properly? Yes No* Were all items on the equipment manufacturer’s maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): Check this box if LLDs are not installed. Complete the following checklist: X Yes No* N/A For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? (Check all that apply) Simulated leak rate: X X Yes No* Were all LLDs confirmed operational and accurate within regulatory requirements? X Yes No* Was the testing apparatus properly calibrated? X Yes No* N/A For mechanical LLDs, does the LLD restrict product flow if it detects a leak? Yes No* X N/A For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? Yes No* X N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? Yes No* X N/A For electronic LLDs, have all accessible wiring connections been visually inspected? X Yes No* Were all items on the equipment manufacturer’s maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. H. Comments: ___________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ __________________________________________________________________________________________________________ Monitoring System Certification Page 3 of 4 12/07 Monitoring System Certification UST Monitoring Site Plan Site Address: ________________________________________________________________________________________________ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date map was drawn: ____/____/____. Instructions If you already have a diagram that shows all required information, you may include it, rather than this page, with your Monitoring System Certification. On your site plan, show the general layout of tanks and piping. Clearly identify locations of the following equipment, if installed: monitoring system control panels; sensors monitoring tank annular spaces, sumps, dispenser pans, spill containers, or other secondary containment areas; mechanical or electronic line leak detectors; and in-tank liquid level probes (if used for leak detection). In the space provided, note the date this Site Plan was prepared. Page _____ of _____05/00 SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: Avo’s Shell Date of Testing: 3/12/2015 Facility Address: 5700 Auburn St. Bakersfield, Ca. Facility Contact: Phone: Date Local Agency Was Notified of Testing : Name of Local Agency Inspector (if present during testing): 2. TESTING CONTRACTOR INFORMATION Company Name: Advanced Compliance Technician Conducting Test: Bruce W. Hinsley Credentials1: X CSLB Contractor  ICC Service Tech.  SWRCB Tank Tester  Other (Specify) __________________ License Number(s): 971259 3. SPILL BUCKET TESTING INFORMATION Test Method Used: X Hydrostatic  Vacuum  Other (Specify)____________________________ Test Equipment Used: Visual Equipment Resolution: Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1 87 UL Fill 2 91 UL Fill 3 Diesel 4 Bucket Installation Type:  Direct Bury X Contained in Sump  Direct Bury X Contained in Sump  Direct Bury X Contained in Sump  Direct Bury  Contained in Sump Bucket Diameter: 11” 11” 11” Bucket Depth: 10” 10” 10” Wait time between applying vacuum/water and start of test: 10 min. 10 Min. 10 Min. Test Start Time (TI): 09:30 09:30 09:30 Initial Reading (RI): 9.25” 9.50” 9.50” Test End Time (TF): 10:30 10:30 10:30 Final Reading (RF): 9.25” 9.50” 9.50” Test Duration (TF – TI): 1 Hr. 1 Hr. 1 Hr. Change in Reading (RF - RI): 0.0” 0.0” 0.0” Pass/Fail Threshold or Criteria: 0.25” 0.25” 0.25” Test Result: X Pass  Fail X Pass  Fail X Pass  Fail  Pass  Fail Comments – (include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician’s Signature:________________________________________________ Date: 3/12/2015 1 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. Monitoring System Certification Form: Addendum for Vacuum/Pressure Interstitial Sensors UN-036A - 1/1 www.unidocs.org Rev. 01/26/06 I. Results of Vacuum/Pressure Monitoring Equipment Testing This page should be used to document testing and servicing of vacuum and pressure interstitial sensors. A copy of this form must be included with the Monitoring System Certification Form, which must be provided to the tank system owner/operator. The owner/operator must submit a copy of the Monitoring System Certification Form to the local agency regulating UST systems within 30 days of test date. Manufacturer: Veeder-Root Model: TLS-350 System Type: Pressure; Vacuum Sensor ID s 8 Component(s) Monitored by this Sensor: 87 Product Line Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail s 10 Component(s) Monitored by this Sensor: 87-91 Vapor Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail s 11 Component(s) Monitored by this Sensor: 87 Vent Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail s 12 Component(s) Monitored by this Sensor: 91 Product Line Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail s 13 Component(s) Monitored by this Sensor: 91 Vent Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail s 14 Component(s) Monitored by this Sensor: Diesel Product Line Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail s 15 Component(s) Monitored by this Sensor: Diesel Vent Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail Component(s) Monitored by this Sensor: Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail Component(s) Monitored by this Sensor: Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail Component(s) Monitored by this Sensor: Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail How was interstitial communication verified? Leak Introduced at Far End of Interstitial Space;1 Gauge; Visual Inspection; Other (Describe in Sec. J, below) Was vacuum/pressure restored to operating levels in all interstitial spaces? Yes No (If no, describe in Sec. J, below) J. Comments: Page 4 of 4 1 If the sensor successfully detects a simulated vacuum/pressure leak introduced in the interstitial space at the furthest point from the sensor, vacuum/pressure has been demonstrated to be communicating throughout the interstice. Advanced Compliance 3704 Littlefalls Ct. Bakersfield, Ca. 93308 661-706-4321 Fax# 661-589-9329 VAPORLESS MANUFACTURING, INC. LDT-890 Leak Detector Test Record Contractor: Advanced Compliance Customer: Avo’s Shell Date: 3/12/2015 Location: 5700 Auburn St. Bakersfield, Ca. Product: 87 UL Technician: Bruce W. Hinsley Submersible Pump Identification Manufacturer: Redjacket Model No.: Serial No.: Notes: Leak Detector Identification Manufacturer: Redjacket Description: FX-1V Diaphragm-type: Piston-type: Tamper-proof seal installed: Other Style Leak Detector: Notes: Leak Detector in Submersible Pump Test at Dispenser Operating Pump Pressure (psi): 29 (para. 15) Gallons per hour rate: 3.0 (para. 22) Line pressure with pump shut off (psi): 16 (para. 23) Bleed-back Test with pump off (ml): 125 (para. 26) Step-through time to full flow (secs): 3 (para. 30) Leak detector stays in leak search position (Yes/No): Yes (para. 42) Leak Detector Test Pass / Fail Notes: Pass *Complete thermal expansion test before failing leak detector Advanced Compliance 3704 Littlefalls Ct. Bakersfield, Ca. 93308 661-706-4321 Fax# 661-589-9329 VAPORLESS MANUFACTURING, INC. LDT-890 Leak Detector Test Record Contractor: Advanced Compliance Customer: Avo’s Shell Date: 3/12/2015 Location: 5700 Auburn St. Bakersfield, Ca. Product: 91 UL Technician: Bruce W. Hinsley Submersible Pump Identification Manufacturer: Redjacket Model No.: Serial No.: Notes: Leak Detector Identification Manufacturer: Redjacket Description: FX-1V Diaphragm-type: Piston-type: Tamper-proof seal installed: Other Style Leak Detector: Notes: Leak Detector in Submersible Pump Test at Dispenser Operating Pump Pressure (psi): 27 (para. 15) Gallons per hour rate: 3.0 (para. 22) Line pressure with pump shut off (psi): 19 (para. 23) Bleed-back Test with pump off (ml): 160 (para. 26) Step-through time to full flow (secs): 3 (para. 30) Leak detector stays in leak search position (Yes/No): Yes (para. 42) Leak Detector Test Pass / Fail Notes: Pass *Complete thermal expansion test before failing leak detector Advanced Compliance 3704 Littlefalls Ct. Bakersfield, Ca. 93308 661-706-4321 Fax# 661-589-9329 VAPORLESS MANUFACTURING, INC. LDT-890 Leak Detector Test Record Contractor: Advanced Compliance Customer: Schwebel Petroleum Date: 3/12/2015 Location: 5700 Auburn St. Bakersfield, Ca. Product: Diesel Technician: Bruce W. Hinsley Submersible Pump Identification Manufacturer: Redjacket Model No.: Serial No.: Notes: Leak Detector Identification Manufacturer: Redjacket Description: FX-1DV Diaphragm-type: Piston-type: Tamper-proof seal installed: Other Style Leak Detector: Notes: Leak Detector in Submersible Pump Test at Dispenser Operating Pump Pressure (psi): 30 (para. 15) Gallons per hour rate: 3.0 (para. 22) Line pressure with pump shut off (psi): 19 (para. 23) Bleed-back Test with pump off (ml): 100 (para. 26) Step-through time to full flow (secs): 3 (para. 30) Leak detector stays in leak search position (Yes/No): Yes (para. 42) Leak Detector Test Pass / Fail Notes: Pass *Complete thermal expansion test before failing leak detector Responses Received: 200 FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 03-12-15 12:48 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 8357 51.57 0.0 69.9 11346 2 PREMIUM 2179 21.78 0.0 72.7 9348 3 DIESEL 4233 35.21 0.0 81.0 7294 I90500 03-12-15 12:48 PM SOFTWARE REVISION LEVEL VERSION 327.04 SOFTWARE# 346327-100-E CREATED - 07.02.06.10.28 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD PMC I50500 03-12-15 12:48 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MM-DD-YY HH:MM:SS xM I50201 03-12-15 12:48 PM SHIFT TIME 1 : 6:00 AM I50202 03-12-15 12:48 PM SHIFT TIME 2 : DISABLED I50203 03-12-15 12:48 PM SHIFT TIME 3 : DISABLED I50204 03-12-15 12:48 PM SHIFT TIME 4 : DISABLED I54600 03-12-15 12:48 PM TANK PER TST NEEDED WRN: DISABLED I54900 03-12-15 12:48 PM TANK ANN TST NEEDED WRN: DISABLED I55300 03-12-15 12:48 PM LINE RE-ENABLE METHOD PASS LINE TEST I55600 03-12-15 12:48 PM LINE PER TST NEEDED WRN: DISABLED I55900 03-12-15 12:48 PM LINE ANN TST NEEDED WRN: DISABLED I50D00 03-12-15 12:48 PM PRINT TC VOLUMES ENABLED I50E00 03-12-15 12:48 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 03-12-15 12:48 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 03-12-15 12:48 PM H-PROTOCOL DATA FORMAT HEIGHT I51A01 03-12-15 12:48 PM DAYLIGHT SAVING TIME ENABLED OFF I51B00 03-12-15 12:48 PM DAYLIGHT SAVING TIME START DATE APR WEEK 1 SUN 2:00 AM END DATE OCT WEEK 6 SUN 2:00 AM I51600 03-12-15 12:48 PM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 03-12-15 12:48 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 03-12-15 12:48 PM TANK CHART SECURITY DISABLED I5BD00 03-12-15 12:48 PM CUSTOM ALARM LABELS DISABLED I56000 03-12-15 12:48 PM MASS/DENSITY DISABLED I88101 03-12-15 12:48 PM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 03-12-15 12:48 PM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 2 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I88103 03-12-15 12:48 PM I88104 03-12-15 12:48 PM I88105 03-12-15 12:48 PM I88106 03-12-15 12:48 PM I52000 03-12-15 12:48 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE MAR 11, 2012 DISABLED 2 ON DATE MAR 11, 2012 DISABLED 3 ON DATE MAR 11, 2012 DISABLED 4 ON DATE MAR 11, 2012 DISABLED 5 ON DATE MAR 11, 2012 DISABLED 6 ON DATE MAR 11, 2012 DISABLED 7 ON DATE MAR 11, 2012 DISABLED 8 ON DATE MAR 11, 2012 DISABLED I60100 03-12-15 12:48 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 PREMIUM ON 3 DIESEL ON 4 OFF I60200 03-12-15 12:48 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 PREMIUM 3 DIESEL 4 I60300 03-12-15 12:48 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 PREMIUM 2 3 DIESEL 3 4 4 I60900 03-12-15 12:48 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 PREMIUM 0.000700 3 DIESEL 0.000450 4 0.000000 I60700 03-12-15 12:48 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 117.75 2 PREMIUM 89.75 3 DIESEL 89.75 4 0.00 I60A00 03-12-15 12:48 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 4 PTS 19703 2 PREMIUM 4 PTS 11527 3 DIESEL 4 PTS 11527 4 1 PT 0 I60400 03-12-15 12:49 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 19703 2 PREMIUM 11527 3 DIESEL 11527 4 0 I60500 03-12-15 12:49 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 19703 16062 9961 3824 2 PREMIUM 11527 9379 5836 2271 3 DIESEL 11527 9379 5836 2271 4 0 0 0 0 I60600 03-12-15 12:49 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 19703 0 0 0 0 16062 0 0 0 0 9961 0 0 0 0 3824 0 0 0 0 2 PREMIUM 11527 0 0 0 0 9379 0 0 0 0 5836 0 0 0 0 2271 0 0 0 0 3 DIESEL 11527 0 0 0 0 9379 0 0 0 0 5836 0 0 0 0 2271 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 03-12-15 12:49 PM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 PREMIUM NO 3 DIESEL NO 4 NO I62F00 03-12-15 12:49 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 3.0 INCHES 2 PREMIUM 3.0 INCHES 3 DIESEL 3.0 INCHES I62700 03-12-15 12:49 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 PREMIUM 2.0 3 DIESEL 2.0 9999FF1B I62400 03-12-15 12:49 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 PREMIUM 3.0 3 DIESEL 3.0 I62800 03-12-15 12:49 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 19703 2 PREMIUM 11527 3 DIESEL 11527 4 0 I62300 03-12-15 12:49 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 18000 2 PREMIUM 10800 3 DIESEL 10800 4 0 I62200 03-12-15 12:49 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 19000 2 PREMIUM 11400 3 DIESEL 11400 4 0 I62900 03-12-15 12:49 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 2000 2 PREMIUM 1200 3 DIESEL 1200 4 0 I62100 03-12-15 12:49 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1500 2 PREMIUM 1000 3 DIESEL 1000 4 0 I62600 03-12-15 12:49 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 PREMIUM 99 3 DIESEL 99 4 99 I62500 03-12-15 12:49 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 50 2 PREMIUM 50 3 DIESEL 50 4 99 I60800 03-12-15 12:49 PM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 PREMIUM 0.00 3 DIESEL 0.00 4 0.00 I60B00 03-12-15 12:49 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 03-12-15 12:49 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 PREMIUM 0.00 3 DIESEL 0.00 4 0.00 I61200 03-12-15 12:49 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED NONE NONE 2 PREMIUM NONE NONE 3 DIESEL NONE NONE 4 NONE NONE I63600 03-12-15 12:49 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 2000 2 PREMIUM 1200 3 DIESEL 1200 4 0 I62A00 03-12-15 12:49 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 2000 2 PREMIUM 1200 3 DIESEL 1200 4 0 I62C00 03-12-15 12:49 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 PREMIUM STANDARD 3 DIESEL STANDARD 4 STANDARD I62D00 03-12-15 12:49 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 03-12-15 12:49 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 PREMIUM OFF OFF 3 DIESEL OFF OFF 4 OFF OFF I63000 03-12-15 12:49 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 OFF I63200 03-12-15 12:49 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 OFF I61000 03-12-15 12:49 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 15 2 PREMIUM 15 3 DIESEL 15 4 1 I63A00 03-12-15 12:49 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 PREMIUM 10.00% 3 DIESEL 10.00% 4 10.00% I61100 03-12-15 12:49 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ANNUALLY: ALL TANK DEC WEEK 1 SUN START TIME : 2:30 AM TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 03-12-15 12:49 PM CSLD PROBABLITY OF DETECTION I61400 03-12-15 12:49 PM CSLD CLIMATE FACTOR I61600 03-12-15 12:49 PM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 PREMIUM IMMEDIATE 3 DIESEL IMMEDIATE 4 IMMEDIATE I61A00 03-12-15 12:49 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED DISABLED 2 PREMIUM DISABLED 3 DIESEL DISABLED 4 DISABLED I61B00 03-12-15 12:49 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 03-12-15 12:49 PM CSLD REPORT ONLY I62B00 03-12-15 12:49 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED 00-00-00 2 PREMIUM 00-00-00 3 DIESEL 00-00-00 4 00-00-00 I63300 03-12-15 12:49 PM LEAK TEST REPORT FORMAT: NORMAL I63400 03-12-15 12:49 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 PREMIUM 0 3 DIESEL 0 4 0 I63500 03-12-15 12:49 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 PREMIUM 1 3 DIESEL 1 4 1 I63900 03-12-15 12:49 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED END FACTOR: NONE 2 PREMIUM END FACTOR: NONE 3 DIESEL END FACTOR: NONE 4 END FACTOR: NONE I78000 03-12-15 12:49 PM I77700 03-12-15 12:49 PM I77800 03-12-15 12:49 PM I78C00 03-12-15 12:49 PM I78300 03-12-15 12:49 PM I78F00 03-12-15 12:49 PM I78700 03-12-15 12:49 PM I70200 03-12-15 12:49 PM LIQUID LABEL DEVICE LABEL 1 UNL TANK ANN 2 PREM TANK ANN 3 DIESEL TANK ANN 4 5 6 7 8 9 DIESEL STP 10 DIESEL STP ANN 11 UNL FILL 12 UNL FILL ANN 13 PREM FILL ANN 14 PREM FILL 15 DIESEL FILL 16 DIESEL FILL ANN 17 DIS 9-10 18 DIS 9-10 ANN 19 DIS 11-12 20 DIS 11-12 ANN 21 UNL STP 22 UNL STP ANN 23 PREM STP 24 PREM STP ANN 25 DIS 1-2 26 DIS 1-2 ANN 27 DIS 3-4 28 DIS 3-4 ANN 29 DIS 5-6 30 DIS 5-6 ANN 31 DIS 7-8 32 DIS 7-8 ANN I70300 03-12-15 12:49 PM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL TANK ANN DUAL POINT HYDROSTATIC 2 PREM TANK ANN DUAL POINT HYDROSTATIC 3 DIESEL TANK ANN DUAL POINT HYDROSTATIC 4 TRI-STATE (SINGLE FLOAT) 5 TRI-STATE (SINGLE FLOAT) 6 TRI-STATE (SINGLE FLOAT) 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) 9 DIESEL STP TRI-STATE (SINGLE FLOAT) 10 DIESEL STP ANN TRI-STATE (SINGLE FLOAT) 11 UNL FILL TRI-STATE (SINGLE FLOAT) 12 UNL FILL ANN TRI-STATE (SINGLE FLOAT) 13 PREM FILL ANN TRI-STATE (SINGLE FLOAT) 14 PREM FILL TRI-STATE (SINGLE FLOAT) 15 DIESEL FILL TRI-STATE (SINGLE FLOAT) 16 DIESEL FILL ANN TRI-STATE (SINGLE FLOAT) 17 DIS 9-10 TRI-STATE (SINGLE FLOAT) 18 DIS 9-10 ANN TRI-STATE (SINGLE FLOAT) 19 DIS 11-12 TRI-STATE (SINGLE FLOAT) 20 DIS 11-12 ANN TRI-STATE (SINGLE FLOAT) 21 UNL STP TRI-STATE (SINGLE FLOAT) 22 UNL STP ANN TRI-STATE (SINGLE FLOAT) 23 PREM STP TRI-STATE (SINGLE FLOAT) 24 PREM STP ANN TRI-STATE (SINGLE FLOAT) 25 DIS 1-2 TRI-STATE (SINGLE FLOAT) 26 DIS 1-2 ANN NORMALLY CLOSED 27 DIS 3-4 TRI-STATE (SINGLE FLOAT) 28 DIS 3-4 ANN TRI-STATE (SINGLE FLOAT) 29 DIS 5-6 TRI-STATE (SINGLE FLOAT) 30 DIS 5-6 ANN TRI-STATE (SINGLE FLOAT) 31 DIS 7-8 TRI-STATE (SINGLE FLOAT) 32 DIS 7-8 ANN TRI-STATE (SINGLE FLOAT) I70400 03-12-15 12:49 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL TANK ANN ANNULAR SPACE 2 PREM TANK ANN ANNULAR SPACE 3 DIESEL TANK ANN ANNULAR SPACE 4 OTHER SENSORS 5 OTHER SENSORS 6 OTHER SENSORS 7 OTHER SENSORS 8 OTHER SENSORS 9 DIESEL STP STP SUMP 10 DIESEL STP ANN ANNULAR SPACE 11 UNL FILL PIPING SUMP 12 UNL FILL ANN ANNULAR SPACE 13 PREM FILL ANN ANNULAR SPACE 14 PREM FILL PIPING SUMP 15 DIESEL FILL PIPING SUMP 16 DIESEL FILL ANN ANNULAR SPACE 17 DIS 9-10 DISPENSER PAN 18 DIS 9-10 ANN ANNULAR SPACE 19 DIS 11-12 DISPENSER PAN 20 DIS 11-12 ANN ANNULAR SPACE 21 UNL STP STP SUMP 22 UNL STP ANN ANNULAR SPACE 23 PREM STP STP SUMP 24 PREM STP ANN ANNULAR SPACE 25 DIS 1-2 DISPENSER PAN 26 DIS 1-2 ANN ANNULAR SPACE 27 DIS 3-4 DISPENSER PAN 28 DIS 3-4 ANN ANNULAR SPACE 29 DIS 5-6 DISPENSER PAN 30 DIS 5-6 ANN ANNULAR SPACE 31 DIS 7-8 DISPENSER PAN 32 DIS 7-8 ANN ANNULAR SPACE I74200 03-12-15 12:49 PM I74300 03-12-15 12:49 PM I74400 03-12-15 12:49 PM I74700 03-12-15 12:49 PM I74800 03-12-15 12:49 PM I74900 03-12-15 12:49 PM I7BC00 03-12-15 12:49 PM I80200 03-12-15 12:49 PM I80300 03-12-15 12:49 PM I80400 03-12-15 12:49 PM I80700 03-12-15 12:49 PM RELAY LABEL DEVICE LABEL 1 87 STP 2 91 STP 3 DIESEL STP 4 OVERFILL ALARM I80900 03-12-15 12:49 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 87 STP NORMALLY OPEN 2 91 STP NORMALLY OPEN 3 DIESEL STP NORMALLY OPEN 4 OVERFILL ALARM NORMALLY OPEN I80B00 03-12-15 12:49 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 87 STP 1 2 91 STP 2 3 DIESEL STP 3 4 OVERFILL ALARM NONE I80A00 03-12-15 12:49 PM RELAY TYPE RELAY DESIGNATION TYPE 1 87 STP PUMP CONTROL OUTPUT 2 91 STP PUMP CONTROL OUTPUT 3 DIESEL STP PUMP CONTROL OUTPUT 4 OVERFILL ALARM STANDARD I80C00 03-12-15 12:49 PM I80800 03-12-15 12:49 PM RELAY SETUP REPORT R 1:87 STP TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L17:FUEL ALARM L19:FUEL ALARM L21:FUEL ALARM L25:FUEL ALARM L27:FUEL ALARM L29:FUEL ALARM L31:FUEL ALARM L17:SENSOR OUT ALARM L19:SENSOR OUT ALARM L21:SENSOR OUT ALARM L25:SENSOR OUT ALARM L27:SENSOR OUT ALARM L29:SENSOR OUT ALARM L31:SENSOR OUT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL R 2:91 STP TYPE: PUMP CONTROL OUTPUT TANK #: 2 LIQUID SENSOR ALMS L17:FUEL ALARM L19:FUEL ALARM L23:FUEL ALARM L25:FUEL ALARM L27:FUEL ALARM L29:FUEL ALARM L31:FUEL ALARM L17:SENSOR OUT ALARM L19:SENSOR OUT ALARM L23:SENSOR OUT ALARM L25:SENSOR OUT ALARM L27:SENSOR OUT ALARM L29:SENSOR OUT ALARM L31:SENSOR OUT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL R 3:DIESEL STP TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 9:FUEL ALARM L17:FUEL ALARM L19:FUEL ALARM L25:FUEL ALARM L27:FUEL ALARM L 9:SENSOR OUT ALARM L17:SENSOR OUT ALARM L19:SENSOR OUT ALARM L25:SENSOR OUT ALARM L27:SENSOR OUT ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM I79000 03-12-15 12:50 PM EDIM:1 VR:349643-001-B TD:97.10.27.11.25 I79100 03-12-15 12:50 PM I72300 03-12-15 12:50 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 PRESS DISP 1-2 VAPOR PRESSURE 02 FM DISP 1-2 AIR FLOW METER 03 FM DISP 3-4 AIR FLOW METER 04 FM DISP 5-6 AIR FLOW METER 05 FM DISP 7-8 AIR FLOW METER 06 FM DISP 9-10 AIR FLOW METER 07 FM DISP 11-12 AIR FLOW METER 08 87 PROD UNKNOWN 09 87 PROD UNKNOWN 10 87-91 VAPOR UNKNOWN 11 87 VENT UNKNOWN 12 91 PROD UNKNOWN 13 91 VENT UNKNOWN 14 DIESEL PROD UNKNOWN 15 DIESEL VENT UNKNOWN 16 ATM PRESS UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN I72A00 03-12-15 12:50 PM VACUUM SENSOR VOLUME DEVICE LABEL VOLUME 8 87 PROD 226.3 GALLONS 9 87 PROD 212.5 GALLONS 10 87-91 VAPOR 254.1 GALLONS 11 87 VENT 69.0 GALLONS 12 91 PROD 226.3 GALLONS 13 91 VENT 55.2 GALLONS 14 DIESEL PROD 240.1 GALLONS 15 DIESEL VENT 45.0 GALLONS IV4E00 03-12-15 12:50 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 03-12-15 12:50 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 03-12-15 12:50 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 VAPOR PROCESSOR TYPE NO VAPOR PROCESSOR IV4700 03-12-15 12:50 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 03-12-15 12:50 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 ACCEPT HIGH ORVR: NO IV4A00 03-12-15 12:50 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 01 01 01 BLEND3 02 02 02 01 BLEND3 03 03 03 02 BLEND3 04 04 04 02 BLEND3 05 05 05 03 BLEND3 06 06 06 03 BLEND3 07 07 07 04 BLEND3 08 08 08 04 BLEND3 09 09 09 05 BLEND3 10 16 10 05 BLEND3 11 17 11 06 BLEND3 12 18 12 06 BLEND3 IV4B00 03-12-15 12:50 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 01/01 09/01 xx/xx 02 01 02/02 01/02 09/02 xx/xx 03 02 02/03 01/03 09/03 xx/xx 04 02 02/04 01/04 09/04 xx/xx 05 03 02/05 01/05 09/05 xx/xx 06 03 02/06 01/06 09/06 xx/xx 07 04 02/07 01/07 09/07 xx/xx 08 04 02/08 01/08 09/08 xx/xx 09 05 02/09 01/09 09/09 xx/xx 16 05 02/10 01/10 09/10 xx/xx 17 06 02/11 01/11 09/11 xx/xx 18 06 02/12 01/12 09/12 xx/xx IV4900 03-12-15 12:50 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 03-12-15 12:50 PM ISD VERSION: 01.01 Responses Received: I10200 03-12-15 12:52 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39486 39455 2 7SMARTSENSOR BD 506092 506111 3 UNUSED 4977955 4968774 4 4 PROBE / G.T. 162897 162906 5 INTERSTITIAL BD 201455 201489 6 INTERSTITIAL BD 201370 201489 7 INTERSTITIAL BD 201497 201446 8 INTERSTITIAL BD 201009 201189 9 RELAY BOARD 14935 14934 10 STP SENSE BOARD 33180 33181 11 UNUSED 4973935 4964503 12 UNUSED 4970580 4963851 13 UNUSED 4968677 4961106 14 UNUSED 4968716 4964562 15 UNUSED 4968441 4962232 16 UNUSED 4970266 4965589 COMM 1 ELEC DISP INT. 101034 101039 COMM 2 RS232 SERIAL BD 14974 14954 COMM 3 UNUSED 4972385 4965885 COMM 4 UNUSED 4969187 4963199 COMM 5 UNUSED 4969403 4966280 COMM 6 UNUSED 4970148 4962686 I90200 03-12-15 12:52 PM SOFTWARE REVISION LEVEL VERSION 327.04 SOFTWARE# 346327-100-E CREATED - 07.02.06.10.28 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD PMC I11100 03-12-15 12:52 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L24 ANNULAR PREM STP ANN FUEL ALARM CLEAR 03-12-15 12:03 PM L24 ANNULAR PREM STP ANN FUEL ALARM ALARM 03-12-15 12:03 PM T 3 TANK DIESEL MAX PRODUCT ALARM CLEAR 03-12-15 11:59 AM T 3 TANK DIESEL PROBE OUT CLEAR 03-12-15 11:59 AM T 3 TANK DIESEL PROBE OUT ALARM 03-12-15 11:59 AM T 3 TANK DIESEL MAX PRODUCT ALARM ALARM 03-12-15 11:58 AM T 3 TANK DIESEL PROBE OUT CLEAR 03-12-15 11:58 AM T 3 TANK DIESEL PROBE OUT ALARM 03-12-15 11:57 AM T 2 TANK PREMIUM MAX PRODUCT ALARM CLEAR 03-12-15 11:38 AM T 2 TANK PREMIUM MAX PRODUCT ALARM ALARM 03-12-15 11:33 AM T 2 TANK PREMIUM LOW PRODUCT ALARM CLEAR 03-12-15 11:33 AM T 2 TANK PREMIUM LOW PRODUCT ALARM ALARM 03-12-15 11:31 AM s15 OTHER DIESEL VENT NO VACUUM ALARM CLEAR 03-12-15 11:22 AM L 3 ANNULAR DIESEL TANK ANN SENSOR OUT ALARM CLEAR 03-12-15 11:04 AM L 2 ANNULAR PREM TANK ANN SENSOR OUT ALARM CLEAR 03-12-15 11:04 AM L 1 ANNULAR UNL TANK ANN SENSOR OUT ALARM CLEAR 03-12-15 11:04 AM L16 ANNULAR DIESEL FILL ANN SENSOR OUT ALARM CLEAR 03-12-15 11:04 AM L15 PIPE DIESEL FILL SENSOR OUT ALARM CLEAR 03-12-15 11:04 AM L14 PIPE PREM FILL SENSOR OUT ALARM CLEAR 03-12-15 11:04 AM L13 ANNULAR PREM FILL ANN SENSOR OUT ALARM CLEAR 03-12-15 11:04 AM L12 ANNULAR UNL FILL ANN SENSOR OUT ALARM CLEAR 03-12-15 11:04 AM L20 ANNULAR DIS 11-12 ANN SENSOR OUT ALARM CLEAR 03-12-15 11:04 AM L11 PIPE UNL FILL SENSOR OUT ALARM CLEAR 03-12-15 11:04 AM L10 ANNULAR DIESEL STP ANN SENSOR OUT ALARM CLEAR 03-12-15 11:04 AM L24 ANNULAR PREM STP ANN SENSOR OUT ALARM CLEAR 03-12-15 11:04 AM L23 STP SUMP PREM STP SENSOR OUT ALARM CLEAR 03-12-15 11:03 AM L 9 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 03-12-15 11:03 AM L18 ANNULAR DIS 9-10 ANN SENSOR OUT ALARM CLEAR 03-12-15 11:03 AM L22 ANNULAR UNL STP ANN SENSOR OUT ALARM CLEAR 03-12-15 11:03 AM L17 DISP PAN DIS 9-10 SENSOR OUT ALARM CLEAR 03-12-15 11:03 AM L21 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 03-12-15 11:03 AM L19 DISP PAN DIS 11-12 SENSOR OUT ALARM CLEAR 03-12-15 11:03 AM L32 ANNULAR DIS 7-8 ANN SENSOR OUT ALARM CLEAR 03-12-15 11:03 AM L31 DISP PAN DIS 7-8 SENSOR OUT ALARM CLEAR 03-12-15 11:03 AM L30 ANNULAR DIS 5-6 ANN SENSOR OUT ALARM CLEAR 03-12-15 11:03 AM L28 ANNULAR DIS 3-4 ANN SENSOR OUT ALARM CLEAR 03-12-15 11:03 AM L25 DISP PAN DIS 1-2 SENSOR OUT ALARM CLEAR 03-12-15 11:03 AM L29 DISP PAN DIS 5-6 SENSOR OUT ALARM CLEAR 03-12-15 11:03 AM L27 DISP PAN DIS 3-4 SENSOR OUT ALARM CLEAR 03-12-15 11:03 AM L26 ANNULAR DIS 1-2 ANN FUEL ALARM CLEAR 03-12-15 11:03 AM L 3 ANNULAR DIESEL TANK ANN SENSOR OUT ALARM ALARM 03-12-15 11:03 AM L 2 ANNULAR PREM TANK ANN SENSOR OUT ALARM ALARM 03-12-15 11:03 AM L 1 ANNULAR UNL TANK ANN SENSOR OUT ALARM ALARM 03-12-15 11:03 AM L20 ANNULAR DIS 11-12 ANN SENSOR OUT ALARM ALARM 03-12-15 11:03 AM L19 DISP PAN DIS 11-12 SENSOR OUT ALARM ALARM 03-12-15 11:03 AM L16 ANNULAR DIESEL FILL ANN SENSOR OUT ALARM ALARM 03-12-15 11:03 AM L24 ANNULAR PREM STP ANN SENSOR OUT ALARM ALARM 03-12-15 11:03 AM L12 ANNULAR UNL FILL ANN SENSOR OUT ALARM ALARM 03-12-15 11:03 AM L21 STP SUMP UNL STP SENSOR OUT ALARM ALARM 03-12-15 11:03 AM L18 ANNULAR DIS 9-10 ANN SENSOR OUT ALARM ALARM 03-12-15 11:03 AM I11200 03-12-15 12:52 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 3 TANK DIESEL HIGH PRODUCT ALARM CLEAR 03-12-15 11:59 AM T 3 TANK DIESEL HIGH PRODUCT ALARM ALARM 03-12-15 11:58 AM T 2 TANK PREMIUM HIGH PRODUCT ALARM CLEAR 03-12-15 11:38 AM T 2 TANK PREMIUM HIGH PRODUCT ALARM ALARM 03-12-15 11:33 AM T 2 TANK PREMIUM DELIVERY NEEDED CLEAR 03-12-15 11:33 AM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 03-12-15 11:31 AM T 1 TANK UNLEADED HIGH PRODUCT ALARM CLEAR 03-12-15 11:27 AM T 1 TANK UNLEADED HIGH PRODUCT ALARM ALARM 03-12-15 11:26 AM OTHER ISD GROSS PRES WARN CLEAR 03-06-15 5:27 PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 03-05-15 12:33 AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 03-04-15 10:11 PM OTHER ISD GROSS PRES WARN ALARM 03-03-15 10:02 AM OTHER ISD GROSS PRES WARN CLEAR 02-25-15 9:16 AM T 2 TANK PREMIUM DELIVERY NEEDED CLEAR 02-23-15 7:07 AM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 02-23-15 6:50 AM OTHER ISD GROSS PRES WARN ALARM 02-19-15 10:03 AM OTHER ISD GROSS PRES WARN CLEAR 02-12-15 11:07 AM OTHER ISD GROSS PRES WARN ALARM 02-06-15 10:02 AM OTHER ISD GROSS PRES WARN CLEAR 01-30-15 11:04 AM OTHER ISD GROSS PRES WARN ALARM 01-30-15 10:01 AM T 2 TANK PREMIUM DELIVERY NEEDED CLEAR 01-24-15 8:17 PM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 01-24-15 7:40 PM SYSTEM PRINTER ERROR CLEAR 01-24-15 2:55 PM SYSTEM PAPER OUT CLEAR 01-24-15 2:55 PM SYSTEM PRINTER ERROR ALARM 01-24-15 2:55 PM SYSTEM PAPER OUT ALARM 01-24-15 2:55 PM OTHER ISD GROSS PRES WARN CLEAR 01-23-15 10:00 AM OTHER ISD GROSS PRES WARN ALARM 01-16-15 10:01 AM T 2 TANK PREMIUM DELIVERY NEEDED CLEAR 01-14-15 4:25 AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 01-14-15 4:04 AM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 01-13-15 8:30 PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 01-13-15 4:53 PM OTHER ISD GROSS PRES WARN CLEAR 01-09-15 12:20 PM T 2 TANK PREMIUM DELIVERY NEEDED CLEAR 01-08-15 11:15 PM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 01-08-15 6:13 PM T 3 TANK DIESEL DELIVERY NEEDED CLEAR 01-08-15 11:15 AM T 3 TANK DIESEL DELIVERY NEEDED ALARM 01-08-15 5:39 AM T 2 TANK PREMIUM DELIVERY NEEDED CLEAR 01-06-15 1:00 AM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 01-05-15 10:25 PM OTHER ISD GROSS PRES WARN ALARM 01-05-15 10:01 AM OTHER ISD GROSS PRES WARN CLEAR 12-29-14 4:16 PM T 2 TANK PREMIUM DELIVERY NEEDED CLEAR 12-26-14 9:06 PM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 12-26-14 5:04 PM OTHER ISD GROSS PRES WARN ALARM 12-24-14 10:01 AM OTHER ISD GROSS PRES WARN CLEAR 12-18-14 9:44 AM T 2 TANK PREMIUM DELIVERY NEEDED CLEAR 12-15-14 9:50 PM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 12-15-14 4:51 PM OTHER ISD GROSS PRES WARN ALARM 12-13-14 10:01 AM T 2 TANK PREMIUM DELIVERY NEEDED CLEAR 12-11-14 8:22 PM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 12-11-14 4:55 PM I20600 03-12-15 12:53 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM 02-27-13 3:05 PM 02-06-07 10:01 AM LOW PRODUCT ALARM 01-13-15 6:36 PM 06-05-14 10:28 PM 02-04-14 12:45 PM SUDDEN LOSS ALARM 02-06-07 9:54 AM HIGH PRODUCT ALARM 03-12-15 11:26 AM 02-27-14 1:27 PM 02-27-13 3:05 PM INVALID FUEL LEVEL 02-27-13 3:07 PM PROBE OUT 02-27-14 1:28 PM 02-27-14 1:26 PM 02-27-13 3:06 PM HIGH WATER WARNING 02-06-07 9:58 AM DELIVERY NEEDED 03-04-15 10:11 PM 01-13-15 4:53 PM 10-15-14 11:47 PM MAX PRODUCT ALARM 02-27-14 1:27 PM TANK 2 PREMIUM LOW PRODUCT ALARM 03-12-15 11:31 AM 12-09-14 8:17 AM 12-03-14 6:03 PM HIGH PRODUCT ALARM 03-12-15 11:33 AM 02-27-14 1:21 PM 02-27-13 2:58 PM INVALID FUEL LEVEL 02-27-14 1:21 PM 02-27-13 3:00 PM PROBE OUT 02-27-14 1:22 PM 02-27-14 1:20 PM 02-27-13 2:59 PM HIGH WATER WARNING 02-06-07 9:56 AM DELIVERY NEEDED 03-12-15 11:31 AM 02-23-15 6:50 AM 01-24-15 7:40 PM MAX PRODUCT ALARM 03-12-15 11:33 AM 02-27-14 1:21 PM 02-27-13 2:58 PM LOW TEMP WARNING 02-27-14 1:23 PM TANK 3 DIESEL HIGH WATER ALARM 02-06-07 10:01 AM LOW PRODUCT ALARM 10-09-14 4:10 PM 07-12-14 5:45 PM 05-30-14 9:32 PM SUDDEN LOSS ALARM 02-06-07 9:55 AM HIGH PRODUCT ALARM 03-12-15 11:58 AM 02-27-14 1:16 PM 02-27-13 2:49 PM INVALID FUEL LEVEL 02-27-14 1:16 PM 02-27-13 2:50 PM PROBE OUT 03-12-15 11:59 AM 03-12-15 11:57 AM 02-27-14 1:17 PM HIGH WATER WARNING 02-06-07 10:01 AM DELIVERY NEEDED 01-08-15 5:39 AM 10-16-14 9:30 AM 10-09-14 11:06 AM MAX PRODUCT ALARM 03-12-15 11:58 AM 02-27-14 1:16 PM 02-27-13 2:49 PM LOW TEMP WARNING 02-27-14 1:18 PM 02-27-13 2:52 PM 02-06-07 10:05 AM I38200 03-12-15 12:53 PM I30200 03-12-15 12:53 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL TANK ANN 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 8:59 AM LOW LIQUID ALARM 09-04-14 2:46 AM HIGH LIQUID ALARM 2 PREM TANK ANN 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 9:00 AM LOW LIQUID ALARM 02-23-15 12:25 PM LOW LIQUID ALARM 3 DIESEL TANK ANN 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 9:01 AM LOW LIQUID ALARM 02-27-14 9:42 AM LOW LIQUID ALARM 9 DIESEL STP 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 9:33 AM FUEL ALARM 05-30-14 11:14 AM FUEL ALARM 10 DIESEL STP ANN 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 8:58 AM FUEL ALARM 02-06-15 10:07 AM FUEL ALARM 11 UNL FILL 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 9:01 AM FUEL ALARM 12-12-14 6:38 AM FUEL ALARM 12 UNL FILL ANN 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 8:49 AM FUEL ALARM 02-19-15 9:48 AM FUEL ALARM 13 PREM FILL ANN 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 8:49 AM FUEL ALARM 02-03-15 9:13 AM FUEL ALARM 14 PREM FILL 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 9:01 AM FUEL ALARM 01-11-15 6:31 AM FUEL ALARM 15 DIESEL FILL 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 9:02 AM FUEL ALARM 02-27-14 9:51 AM FUEL ALARM 16 DIESEL FILL ANN 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 8:50 AM FUEL ALARM 11-05-14 12:15 PM FUEL ALARM 17 DIS 9-10 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 10:17 AM FUEL ALARM 03-12-15 9:57 AM FUEL ALARM 18 DIS 9-10 ANN 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 9:56 AM FUEL ALARM 02-27-14 11:44 AM FUEL ALARM 19 DIS 11-12 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 10:20 AM FUEL ALARM 02-27-14 11:49 AM FUEL ALARM 20 DIS 11-12 ANN 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 10:19 AM FUEL ALARM 02-27-14 11:49 AM FUEL ALARM 21 UNL STP 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 9:30 AM FUEL ALARM 06-24-14 10:52 PM FUEL ALARM 22 UNL STP ANN 03-12-15 11:02 AM SENSOR OUT ALARM 03-12-15 8:42 AM FUEL ALARM 12-15-14 2:35 PM FUEL ALARM 23 PREM STP 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 9:31 AM FUEL ALARM 02-27-14 10:28 AM FUEL ALARM 24 PREM STP ANN 03-12-15 12:03 PM FUEL ALARM 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 8:48 AM FUEL ALARM 25 DIS 1-2 03-12-15 11:02 AM SENSOR OUT ALARM 03-12-15 9:44 AM FUEL ALARM 02-27-14 10:54 AM FUEL ALARM 26 DIS 1-2 ANN 03-12-15 11:02 AM FUEL ALARM 03-12-15 9:44 AM FUEL ALARM 02-27-14 10:53 AM FUEL ALARM 27 DIS 3-4 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 9:48 AM FUEL ALARM 02-27-14 11:05 AM FUEL ALARM 28 DIS 3-4 ANN 03-12-15 11:02 AM SENSOR OUT ALARM 03-12-15 9:48 AM FUEL ALARM 03-25-14 5:21 PM FUEL ALARM 29 DIS 5-6 03-12-15 11:02 AM SENSOR OUT ALARM 03-12-15 9:51 AM FUEL ALARM 02-27-14 11:25 AM FUEL ALARM 30 DIS 5-6 ANN 03-12-15 11:02 AM SENSOR OUT ALARM 02-27-14 11:18 AM FUEL ALARM 02-27-13 3:28 PM FUEL ALARM 31 DIS 7-8 03-12-15 11:02 AM SENSOR OUT ALARM 03-12-15 9:55 AM FUEL ALARM 02-27-14 11:36 AM FUEL ALARM 32 DIS 7-8 ANN 03-12-15 11:03 AM SENSOR OUT ALARM 03-12-15 9:54 AM FUEL ALARM 08-26-14 6:49 PM FUEL ALARM I31600 03-12-15 12:53 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PRESS DISP 1-2 2 FM DISP 1-2 3 FM DISP 3-4 4 FM DISP 5-6 5 FM DISP 7-8 6 FM DISP 9-10 7 FM DISP 11-12 8 87 PROD 03-12-15 9:22 AM HIGH LIQUID ALARM 03-12-15 8:42 AM NO VACUUM ALARM 06-20-14 9:26 AM NO VACUUM ALARM 10 87-91 VAPOR 03-12-15 9:22 AM HIGH LIQUID ALARM 03-12-15 8:41 AM NO VACUUM ALARM 02-27-14 12:27 PM HIGH LIQUID ALARM 11 87 VENT 03-12-15 9:22 AM HIGH LIQUID ALARM 03-12-15 8:41 AM NO VACUUM ALARM 02-15-15 3:33 AM NO VACUUM ALARM 12 91 PROD 03-12-15 9:21 AM HIGH LIQUID ALARM 03-12-15 8:46 AM NO VACUUM ALARM 11-05-14 1:20 PM COMMUNICATION ALARM 14 DIESEL PROD 03-12-15 9:16 AM HIGH LIQUID ALARM 03-12-15 8:57 AM NO VACUUM ALARM 06-04-14 7:56 AM HIGH LIQUID ALARM 15 DIESEL VENT 03-12-15 9:35 AM SENSOR FAULT ALARM 03-12-15 9:16 AM HIGH LIQUID ALARM 03-12-15 9:16 AM SENSOR FAULT ALARM 16 ATM PRESS I40200 03-12-15 12:53 PM I40300 03-12-15 12:53 PM I34200 03-12-15 12:53 PM I34700 03-12-15 12:53 PM IV0100 03-12-15 12:53 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.01 VAPOR PROCESSOR TYPE: NO VAPOR PROCESSOR OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% STAGE I TRANSFERS: 0 of 0 NOTEST EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 15-03-06 10:03:01 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.72 15-03-05 10:03:01 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 4.04 15-03-04 10:02:48 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 4.27 15-03-03 10:02:45 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 4.36 15-02-24 10:03:14 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.67 15-02-23 10:03:25 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.67 15-02-22 10:03:44 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.67 15-02-21 10:04:26 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.55 15-02-20 10:04:30 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.41 15-02-19 10:03:33 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.47 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 15-01-23 10:01:59 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.84 14-08-14 10:04:41 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.76 14-07-14 10:03:29 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD 14-06-01 10:03:37 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 14-03-12 10:03:03 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.48 13-09-28 10:03:07 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 BLKD 13-09-04 10:03:02 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.45 13-08-01 10:04:02 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.70 13-03-29 10:04:02 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.64 13-03-13 10:04:00 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.71 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 15-03-12 11:40:40 READINESS ISD:PP EVR:NN EVR READINESS PENDING 15-03-12 11:40:40 ISD STARTUP 15-03-12 11:40:33 ISD SHUTDOWN 15-03-12 11:11:47 READINESS ISD:PP EVR:NN EVR READINESS PENDING 15-03-12 11:11:47 ISD STARTUP 15-03-12 11:08:19 ISD SHUTDOWN 15-03-12 11:06:40 READINESS ISD:PP EVR:NN EVR READINESS PENDING 15-03-12 11:06:40 ISD STARTUP 15-03-12 11:06:30 ISD SHUTDOWN 15-03-12 10:13:08 READINESS ISD:PP EVR:NN EVR READINESS PENDING