Loading...
HomeMy WebLinkAboutFMC 2016MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of CaliforniaAuthority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A.General Information Facility Name:Bldg. No.: Site Address:City:Zip: Facility Contact Person: Contact Phone No.: Make/Model of Monitoring System:Date of Testing/Servicing: B.Inventory of Equipment Tested/Certified Check the appropriate boxes to indicate specific equipment inspected/serviced: Tank ID:Tank ID: In-Tank Gauging Probe.Model:In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model:Annular Space or Vault Sensor.Model: Piping Sump / Trench Sensor(s).Model:Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model:Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model:Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Electronic LineLeak Detector.Model: Tank Overfill / High-Level Sensor.Model:Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2).Other (specify equipment type and model in Section E on Page 2). Tank ID:Tank ID: In-Tank Gauging Probe.Model:In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model:Annular Space or Vault Sensor.Model: Piping Sump / TrenchSensor(s).Model:Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model:Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model:Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Electronic Line Leak Detector.Model: Tank Overfill / High-Level Sensor.Model:Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2).Other (specify equipment type and model in Section E on Page 2). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C.Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers’ guidelines. Attached to this Certification is information (e.g. manufacturers' checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report;(check all that apply):System set-up Alarm history report Technician Name (print):Signature: Certification No.:License. No.:804904 Testing Company Name:Confidence UST Services, Inc.Phone No.:(800)339-9930 Site Address:Date of Testing/Servicing: Page 1 of 3 Samco#4 4100CaliforniaAvenue SamJouda 02/09/2016 10,000gal.RegularNorth 847390-107 794390-407 Ronan 794390-420 Ronan Ronan Ronan FX1V OPW61-SO 10,000gal.RegularSouth 847390-107 FX1V OPW61-SO 10,000gal.Regular-Siphon 847390-107 794390-407 ■794390-407 794390-420 Ronan 794380-208 Ronan OPW61-SO 10,000gal.Super 847390-107 FX1V OPW61-SO 1-2 3-4 5-6 7-8 9-10 11-12 4100CaliforniaAvenue 02/09/2016 Bakersfield 93309 Veeder-Root TLS-350 X X Dustin Reese B43426 , Bakersfield, CA 93309 (661) 393-7000 MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of CaliforniaAuthority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A.General Information Facility Name:Bldg. No.: Site Address:City:Zip: Facility Contact Person: Contact Phone No.: Make/Model of Monitoring System:Date of Testing/Servicing: B.Inventory of Equipment Tested/Certified Check the appropriate boxes to indicate specific equipment inspected/serviced: Tank ID:Tank ID: In-Tank Gauging Probe.Model:In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model:Annular Space or Vault Sensor.Model: Piping Sump / Trench Sensor(s).Model:Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model:Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model:Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Electronic LineLeak Detector.Model: Tank Overfill / High-Level Sensor.Model:Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2).Other (specify equipment type and model in Section E on Page 2). Tank ID:Tank ID: In-Tank Gauging Probe.Model:In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model:Annular Space or Vault Sensor.Model: Piping Sump / TrenchSensor(s).Model:Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model:Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model:Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Electronic Line Leak Detector.Model: Tank Overfill / High-Level Sensor.Model:Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2).Other (specify equipment type and model in Section E on Page 2). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C.Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers’ guidelines. Attached to this Certification is information (e.g. manufacturers' checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report;(check all that apply):System set-up Alarm history report Technician Name (print):Signature: Certification No.:License. No.:804904 Testing Company Name:Confidence UST Services, Inc.Phone No.:(800)339-9930 Site Address:Date of Testing/Servicing: Page 1 of 3 6DPFR &DOLIRUQLD$YHQXH %DNHUVILHOG 6DP-RXGD   9HHGHU5RRW7/6 'XVWLQ5HHVH % &DOLIRUQLD$YHQXH%DNHUVILHOG&$ Veeder-RootTLS-350 10,000gal.Diesel ■847390-107 ■794390-407 ■Ronan ■794380-208 ■FX1DV ■OPW61-SO B43426 Monitoring System Certification D.Results of Testing/Servicing Software Version Installed: Complete the following checklist: Yes No*Isthe audible alarm operational? Yes No*Is the visual alarm operational? Yes No*Were all sensors visually inspected, functionally tested, and confirmed operational? Yes No*Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* N/A If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) operational? Yes No* N/A For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) Sump/Trench Sensors; Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection? Yes; No. Yes No* N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent oftank capacity does the alarm trigger? % Yes*NoWas any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes*NoWas liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) Product; Water. If yes, describe causes in Section E, below. Yes No*Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable Yes No*Is all monitoring equipment operational per manufacturer’s specifications? *In Section E below, describe how and when these deficiencies were or will be corrected. E.Comments: Page 2 of 3 327.04 There are two unleaded tanks and 1 unleaded slave tank that are not alternating properly like they should. The problem is that the Pump sense module and relays they are not powered and wired right and will need to be fixed. There is also a wiring issue with the annular sensors and these issues will need to be fixed before I can certify the whole monitors cert. I had to change out the annular sensor for the slave tank , I changed the Ronan sensor with a Veeder-Root 407 annular sensor. There are two spill both Fill spill buckets the unleaded north and super the do not hold 5 gallons, and will need to be fixed to properly hold 5 gallons. The Diesel fill spill bucket failed testing and will need to be replaced and retested. Monitoring System Certification F.In-Tank Gauging / SIR Equipment: Check this box if tank gauging is used only for inventory control. Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: Yes No*Has all input wiring been inspected for proper entry and termination, including testing for ground faults? Yes No*Were all tank gauging probes visually inspected for damage and residue buildup? Yes No*Was accuracy of system product level readings tested? Yes No*Was accuracy of system water level readings tested? Yes No*Were all probes reinstalled properly? Yes No*Were all items on the equipment manufacturer’s maintenance checklist completed? *In the Section H, below, describe how and when these deficiencies were or will be corrected. G.Line Leak Detectors (LLD):Check this box if LLDs are not installed. Complete the following checklist: Yes No* N/A For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? (Check all that apply)Simulated leak rate: 3 g.p.h.; 0.1 g.p.h ; 0.2 g.p.h. Yes No*Were all LLDs confirmed operational and accurate within regulatory requirements? Yes No*Was the testing apparatus properly calibrated? Yes No* N/A For mechanical LLDs, does the LLD restrict product flow if it detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? Yes No* N/A For electronic LLDs, have all accessible wiring connections been visually inspected? Yes No*Were all items on the equipment manufacturer’s maintenance checklist completed? *In the Section H, below, describe how and when these deficiencies were or will be corrected. H.Comments: Page 3 of 3 The wiring need to be checked and fixed for all sensors and probes, before monitoring certification can be completed. The LLD for unleaded south was not tested due to the fact that there was A issue with the tanks alternating. All the other LLD were tested and working Per manufacturers specs. Leak Detector Test Results Sheet Customer Address: Work Order: Site Address: Test Date: Site Contact: Phone: Technician: Phone: 800-339-9930 ICC No.: Product Type LLD Type Model Serial No. Check Valve Holding Pressure Bleed Off ML. Leak Rate Tested: Pass/Fail 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi Technician Name: Technician No.: Signature: Date: HW&JEnterprises,Inc. CaliforniaChevron 3817WilsonRd.,Ste.B Bakersfield,CA93309 35895 02/09/2016 Regular-No Mechanical FX1V SamJouda 4100CaliforniaAvenue Samco#4 12psi165ml Pass FX1VMechanicalRegular-So Fail FX1VMechanicalPremium 10psi150ml Pass FX1DVMechanicalDiesel 12psi400ml Pass 02/09/2016 Bakersfield, CA 93309 Dustin Reese 661-393-7000 8216722-UT Dustin Reese B42436 204121 California Chevron System Setup: Responses Received: 200 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 FEB 9, 2016 9:31 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED NORTH 5059 45.89 0.0 62.7 4625 2 SUPREME 4018 38.52 0.0 60.6 5666 3 UNLEADED SIPHON 2804 29.63 0.0 63.5 6880 4 UNLEADED SOUTH 4353 40.89 0.8 63.0 5331 5 DIESEL 2182 24.76 0.0 68.8 7502 I90500 FEB 9, 2016 9:31 AM SOFTWARE REVISION LEVEL VERSION 327.04 SOFTWARE# 346327-100-E CREATED - 07.02.06.10.28 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD PMC I50500 FEB 9, 2016 9:31 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 FEB 9, 2016 9:31 AM SHIFT TIME 1 : 5:00 AM I50202 FEB 9, 2016 9:31 AM SHIFT TIME 2 : DISABLED I50203 FEB 9, 2016 9:31 AM SHIFT TIME 3 : DISABLED I50204 FEB 9, 2016 9:31 AM SHIFT TIME 4 : DISABLED I54600 FEB 9, 2016 9:31 AM TANK PER TST NEEDED WRN: DISABLED I54900 FEB 9, 2016 9:31 AM TANK ANN TST NEEDED WRN: DISABLED I55300 FEB 9, 2016 9:31 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 FEB 9, 2016 9:31 AM LINE PER TST NEEDED WRN: DISABLED I55900 FEB 9, 2016 9:31 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 FEB 9, 2016 9:31 AM PRINT TC VOLUMES ENABLED I50E00 FEB 9, 2016 9:31 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 FEB 9, 2016 9:31 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 FEB 9, 2016 9:31 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 FEB 9, 2016 9:31 AM DAYLIGHT SAVING TIME ENABLED OFF I51B00 FEB 9, 2016 9:31 AM DAYLIGHT SAVING TIME START DATE APR WEEK 1 SUN 2:00 AM END DATE OCT WEEK 6 SUN 2:00 AM I51600 FEB 9, 2016 9:31 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 FEB 9, 2016 9:31 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 00 ENABLED 3 00 ENABLED 4 00 ENABLED 5 000000 DISABLED 6 00 ENABLED I21900 FEB 9, 2016 9:31 AM TANK CHART SECURITY DISABLED I5BD00 FEB 9, 2016 9:31 AM CUSTOM ALARM LABELS DISABLED I56000 FEB 9, 2016 9:31 AM MASS/DENSITY DISABLED I88101 FEB 9, 2016 9:31 AM PORT SETTINGS: COMM BOARD : 1 (RS-232) BAUD RATE : 9600 PARITY : EVEN STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I88102 FEB 9, 2016 9:31 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : EVEN STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : 00 I88103 FEB 9, 2016 9:31 AM PORT SETTINGS: COMM BOARD : 3 (EDIM ) RS-232 SECURITY CODE : 00 I88104 FEB 9, 2016 9:31 AM I88105 FEB 9, 2016 9:31 AM PORT SETTINGS: COMM BOARD : 5 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED DTR NORMAL STATE: HIGH I88106 FEB 9, 2016 9:31 AM I52000 FEB 9, 2016 9:31 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE AUG 12, 2008 DISABLED 2 ON DATE DEC 22, 2010 DISABLED 3 ON DATE DEC 22, 2010 DISABLED 4 ON DATE DEC 22, 2010 DISABLED 5 ON DATE DEC 22, 2010 DISABLED 6 ON DATE DEC 22, 2010 DISABLED 7 ON DATE DEC 22, 2010 DISABLED 8 VEEDER ROOT (FMS) WEEKLY WED 4:07 PM I60100 FEB 9, 2016 9:31 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED NORTH ON 2 SUPREME ON 3 UNLEADED SIPHON ON 4 UNLEADED SOUTH ON 5 DIESEL ON 6 OFF 7 OFF 8 OFF I60200 FEB 9, 2016 9:31 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED NORTH 2 SUPREME 3 UNLEADED SIPHON 4 UNLEADED SOUTH 5 DIESEL 6 7 8 I60300 FEB 9, 2016 9:31 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED NORTH 1 2 SUPREME 2 3 UNLEADED SIPHON 3 4 UNLEADED SOUTH 4 5 DIESEL 5 6 6 7 7 8 8 I60900 FEB 9, 2016 9:31 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED NORTH 0.000700 2 SUPREME 0.000700 3 UNLEADED SIPHON 0.000700 4 UNLEADED SOUTH 0.000700 5 DIESEL 0.000700 6 0.000000 7 0.000000 8 0.000000 I60700 FEB 9, 2016 9:31 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED NORTH 89.75 2 SUPREME 89.75 3 UNLEADED SIPHON 89.75 4 UNLEADED SOUTH 89.75 5 DIESEL 89.75 6 0.00 7 0.00 8 0.00 I60A00 FEB 9, 2016 9:31 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED NORTH 4 PTS 9684 2 SUPREME 4 PTS 9684 3 UNLEADED SIPHON 4 PTS 9684 4 UNLEADED SOUTH 4 PTS 9684 5 DIESEL 4 PTS 9684 6 4 PTS 0 7 4 PTS 0 8 4 PTS 0 I60400 FEB 9, 2016 9:31 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED NORTH 9684 2 SUPREME 9684 3 UNLEADED SIPHON 9684 4 UNLEADED SOUTH 9684 5 DIESEL 9684 6 0 7 0 8 0 I60500 FEB 9, 2016 9:31 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED NORTH 9684 7891 4918 1900 2 SUPREME 9684 7891 4918 1900 3 UNLEADED SIPHON 9684 7891 4918 1900 4 UNLEADED SOUTH 9684 7891 4918 1900 5 DIESEL 9684 7891 4918 1900 6 0 0 0 0 7 0 0 0 0 8 0 0 0 0 I60600 FEB 9, 2016 9:31 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED NORTH 9684 0 0 0 0 7891 0 0 0 0 4918 0 0 0 0 1900 0 0 0 0 2 SUPREME 9684 0 0 0 0 7891 0 0 0 0 4918 0 0 0 0 1900 0 0 0 0 3 UNLEADED SIPHON 9684 0 0 0 0 7891 0 0 0 0 4918 0 0 0 0 1900 0 0 0 0 4 UNLEADED SOUTH 9684 0 0 0 0 7891 0 0 0 0 4918 0 0 0 0 1900 0 0 0 0 5 DIESEL 9684 0 0 0 0 7891 0 0 0 0 4918 0 0 0 0 1900 0 0 0 0 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 FEB 9, 2016 9:31 AM TANK PRODUCT LABEL METER DATA 1 UNLEADED NORTH NO 2 SUPREME NO 3 UNLEADED SIPHON NO 4 UNLEADED SOUTH NO 5 DIESEL NO 6 NO 7 NO 8 NO I62F00 FEB 9, 2016 9:31 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED NORTH 2.0 INCHES 2 SUPREME 4.0 INCHES 3 UNLEADED SIPHON 2.0 INCHES 4 UNLEADED SOUTH 2.0 INCHES 5 DIESEL 4.0 INCHES I62700 FEB 9, 2016 9:31 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED NORTH 2.0 2 SUPREME 2.0 3 UNLEADED SIPHON 2.0 4 UNLEADED SOUTH 2.0 5 DIESEL 2.0 9999FF1B I62400 FEB 9, 2016 9:31 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED NORTH 3.0 2 SUPREME 3.0 3 UNLEADED SIPHON 3.0 4 UNLEADED SOUTH 3.0 5 DIESEL 3.0 I62800 FEB 9, 2016 9:31 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED NORTH 9684 2 SUPREME 9684 3 UNLEADED SIPHON 9684 4 UNLEADED SOUTH 9684 5 DIESEL 9684 6 0 7 0 8 0 I62300 FEB 9, 2016 9:31 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED NORTH 9000 2 SUPREME 9000 3 UNLEADED SIPHON 9000 4 UNLEADED SOUTH 9000 5 DIESEL 9000 6 0 7 0 8 0 I62200 FEB 9, 2016 9:31 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED NORTH 9500 2 SUPREME 9500 3 UNLEADED SIPHON 9500 4 UNLEADED SOUTH 9500 5 DIESEL 9500 6 0 7 0 8 0 I62900 FEB 9, 2016 9:31 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED NORTH 500 2 SUPREME 500 3 UNLEADED SIPHON 500 4 UNLEADED SOUTH 500 5 DIESEL 500 6 0 7 0 8 0 I62100 FEB 9, 2016 9:31 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED NORTH 500 2 SUPREME 500 3 UNLEADED SIPHON 500 4 UNLEADED SOUTH 500 5 DIESEL 500 6 0 7 0 8 0 I62600 FEB 9, 2016 9:31 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED NORTH 99 2 SUPREME 99 3 UNLEADED SIPHON 99 4 UNLEADED SOUTH 99 5 DIESEL 99 6 99 7 99 8 99 I62500 FEB 9, 2016 9:31 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED NORTH 99 2 SUPREME 99 3 UNLEADED SIPHON 99 4 UNLEADED SOUTH 99 5 DIESEL 99 6 99 7 99 8 99 I60800 FEB 9, 2016 9:31 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED NORTH 0.49 2 SUPREME 3.40 3 UNLEADED SIPHON 0.26 4 UNLEADED SOUTH 0.14 5 DIESEL 4.70 6 0.00 7 0.00 8 0.00 I60B00 FEB 9, 2016 9:31 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 FEB 9, 2016 9:31 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED NORTH 0.00 2 SUPREME 0.00 3 UNLEADED SIPHON 0.00 4 UNLEADED SOUTH 0.00 5 DIESEL 0.00 6 0.00 7 0.00 8 0.00 I61200 FEB 9, 2016 9:31 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED NORTH 3, 4 4 2 SUPREME NONE NONE 3 UNLEADED SIPHON 1, 4 NONE 4 UNLEADED SOUTH 1, 3 1 5 DIESEL NONE NONE 6 NONE NONE 7 NONE NONE 8 NONE NONE I63600 FEB 9, 2016 9:31 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED NORTH 100 2 SUPREME 100 3 UNLEADED SIPHON 100 4 UNLEADED SOUTH 100 5 DIESEL 100 6 0 7 0 8 0 I62A00 FEB 9, 2016 9:31 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED NORTH 100 2 SUPREME 100 3 UNLEADED SIPHON 100 4 UNLEADED SOUTH 100 5 DIESEL 100 6 0 7 0 8 0 I62C00 FEB 9, 2016 9:31 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED NORTH STANDARD 2 SUPREME STANDARD 3 UNLEADED SIPHON STANDARD 4 UNLEADED SOUTH STANDARD 5 DIESEL STANDARD 6 STANDARD 7 STANDARD 8 STANDARD I62D00 FEB 9, 2016 9:31 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED NORTH GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 SUPREME GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 UNLEADED SIPHON GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 UNLEADED SOUTH GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 5 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 6 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 7 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 8 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 FEB 9, 2016 9:31 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED NORTH OFF OFF 2 SUPREME OFF OFF 3 UNLEADED SIPHON OFF OFF 4 UNLEADED SOUTH OFF OFF 5 DIESEL OFF OFF 6 OFF OFF 7 OFF OFF 8 OFF OFF I63000 FEB 9, 2016 9:31 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED NORTH OFF 2 SUPREME OFF 3 UNLEADED SIPHON OFF 4 UNLEADED SOUTH OFF 5 DIESEL OFF 6 OFF 7 OFF 8 OFF I63200 FEB 9, 2016 9:31 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED NORTH OFF 2 SUPREME OFF 3 UNLEADED SIPHON OFF 4 UNLEADED SOUTH OFF 5 DIESEL OFF 6 OFF 7 OFF 8 OFF I61000 FEB 9, 2016 9:31 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED NORTH 1 2 SUPREME 1 3 UNLEADED SIPHON 1 4 UNLEADED SOUTH 1 5 DIESEL 1 6 1 7 1 8 1 I63A00 FEB 9, 2016 9:31 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED NORTH 10.00% 2 SUPREME 10.00% 3 UNLEADED SIPHON 10.00% 4 UNLEADED SOUTH 10.00% 5 DIESEL 10.00% 6 10.00% 7 10.00% 8 10.00% I61100 FEB 9, 2016 9:31 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK FEB 6, 2007 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 FEB 9, 2016 9:31 AM CSLD PROBABLITY OF DETECTION I61400 FEB 9, 2016 9:31 AM CSLD CLIMATE FACTOR I61600 FEB 9, 2016 9:31 AM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED NORTH IMMEDIATE 2 SUPREME IMMEDIATE 3 UNLEADED SIPHON IMMEDIATE 4 UNLEADED SOUTH IMMEDIATE 5 DIESEL IMMEDIATE 6 IMMEDIATE 7 IMMEDIATE 8 IMMEDIATE I61A00 FEB 9, 2016 9:31 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED NORTH DISABLED 2 SUPREME DISABLED 3 UNLEADED SIPHON DISABLED 4 UNLEADED SOUTH DISABLED 5 DIESEL DISABLED 6 DISABLED 7 DISABLED 8 DISABLED I61B00 FEB 9, 2016 9:31 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 FEB 9, 2016 9:31 AM CSLD REPORT ONLY I62B00 FEB 9, 2016 9:31 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED NORTH ??? 0, 0 2 SUPREME ??? 0, 0 3 UNLEADED SIPHON ??? 0, 0 4 UNLEADED SOUTH ??? 0, 0 5 DIESEL ??? 0, 0 6 ??? 0, 0 7 ??? 0, 0 8 ??? 0, 0 I63300 FEB 9, 2016 9:32 AM LEAK TEST REPORT FORMAT: NORMAL I63400 FEB 9, 2016 9:32 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED NORTH 0 2 SUPREME 0 3 UNLEADED SIPHON 0 4 UNLEADED SOUTH 0 5 DIESEL 0 6 0 7 0 8 0 I63500 FEB 9, 2016 9:32 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED NORTH 1 2 SUPREME 1 3 UNLEADED SIPHON 1 4 UNLEADED SOUTH 1 5 DIESEL 1 6 1 7 1 8 1 I63900 FEB 9, 2016 9:32 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED NORTH END FACTOR: NONE 2 SUPREME END FACTOR: NONE 3 UNLEADED SIPHON END FACTOR: NONE 4 UNLEADED SOUTH END FACTOR: NONE 5 DIESEL END FACTOR: NONE 6 END FACTOR: NONE 7 END FACTOR: NONE 8 END FACTOR: NONE I78000 FEB 9, 2016 9:32 AM I77700 FEB 9, 2016 9:32 AM I77800 FEB 9, 2016 9:32 AM I78C00 FEB 9, 2016 9:32 AM I78300 FEB 9, 2016 9:32 AM I78F00 FEB 9, 2016 9:32 AM I78700 FEB 9, 2016 9:32 AM I70200 FEB 9, 2016 9:32 AM LIQUID LABEL DEVICE LABEL 1 UNLEADED NORTH STP 2 SUPREME STP 3 UNLEADED SIPHON STP 4 UNLEADED SOUTH STP 5 DIESEL STP 6 UNL NORTH FILL 7 SUPREME FILL 8 UNL SIPHON FILL 9 UNL SOUTH FILL 10 DIESEL FILL 11 UNL ANNULAR 12 SUPREME ANNULAR 13 UNL SIPHON ANNULAR 14 UNL SOUTH ANNULAR 15 DIESEL ANNULAR 16 DIESEL FILL I70300 FEB 9, 2016 9:32 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNLEADED NORTH STP TRI-STATE (SINGLE FLOAT) 2 SUPREME STP TRI-STATE (SINGLE FLOAT) 3 UNLEADED SIPHON STP TRI-STATE (SINGLE FLOAT) 4 UNLEADED SOUTH STP TRI-STATE (SINGLE FLOAT) 5 DIESEL STP TRI-STATE (SINGLE FLOAT) 6 UNL NORTH FILL TRI-STATE (SINGLE FLOAT) 7 SUPREME FILL TRI-STATE (SINGLE FLOAT) 8 UNL SIPHON FILL TRI-STATE (SINGLE FLOAT) 9 UNL SOUTH FILL TRI-STATE (SINGLE FLOAT) 10 DIESEL FILL TRI-STATE (SINGLE FLOAT) 11 UNL ANNULAR TRI-STATE (SINGLE FLOAT) 12 SUPREME ANNULAR NORMALLY CLOSED 13 UNL SIPHON ANNULAR NORMALLY CLOSED 14 UNL SOUTH ANNULAR NORMALLY CLOSED 15 DIESEL ANNULAR NORMALLY CLOSED 16 DIESEL FILL NORMALLY CLOSED I70400 FEB 9, 2016 9:32 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNLEADED NORTH STP OTHER SENSORS 2 SUPREME STP OTHER SENSORS 3 UNLEADED SIPHON STP OTHER SENSORS 4 UNLEADED SOUTH STP OTHER SENSORS 5 DIESEL STP STP SUMP 6 UNL NORTH FILL OTHER SENSORS 7 SUPREME FILL OTHER SENSORS 8 UNL SIPHON FILL OTHER SENSORS 9 UNL SOUTH FILL OTHER SENSORS 10 DIESEL FILL OTHER SENSORS 11 UNL ANNULAR ANNULAR SPACE 12 SUPREME ANNULAR ANNULAR SPACE 13 UNL SIPHON ANNULAR ANNULAR SPACE 14 UNL SOUTH ANNULAR ANNULAR SPACE 15 DIESEL ANNULAR ANNULAR SPACE 16 DIESEL FILL OTHER SENSORS I74200 FEB 9, 2016 9:32 AM I74300 FEB 9, 2016 9:32 AM I74400 FEB 9, 2016 9:32 AM I74700 FEB 9, 2016 9:32 AM I74800 FEB 9, 2016 9:32 AM I74900 FEB 9, 2016 9:32 AM I7BC00 FEB 9, 2016 9:32 AM I80200 FEB 9, 2016 9:32 AM I80300 FEB 9, 2016 9:32 AM I80400 FEB 9, 2016 9:32 AM I80700 FEB 9, 2016 9:32 AM RELAY LABEL DEVICE LABEL 1 SUPREME 2 UNLEADED NORTH 3 UNLEADED SOUTH 4 DIESEL I80900 FEB 9, 2016 9:32 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 SUPREME NORMALLY CLOSED 2 UNLEADED NORTH NORMALLY OPEN 3 UNLEADED SOUTH NORMALLY OPEN 4 DIESEL NORMALLY CLOSED I80B00 FEB 9, 2016 9:32 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 SUPREME 2 2 UNLEADED NORTH 1 3 UNLEADED SOUTH 4 4 DIESEL 5 I80A00 FEB 9, 2016 9:32 AM RELAY TYPE RELAY DESIGNATION TYPE 1 SUPREME STANDARD 2 UNLEADED NORTH PUMP CONTROL OUTPUT 3 UNLEADED SOUTH PUMP CONTROL OUTPUT 4 DIESEL STANDARD I80C00 FEB 9, 2016 9:32 AM I80800 FEB 9, 2016 9:32 AM RELAY SETUP REPORT R 1:SUPREME TYPE: STANDARD NORMALLY CLOSED TANK #: 2 LIQUID SENSOR ALMS L 2:FUEL ALARM L 2:SENSOR OUT ALARM L 2:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:UNLEADED NORTH TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 1:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 1:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:UNLEADED SOUTH TYPE: PUMP CONTROL OUTPUT TANK #: 4 LIQUID SENSOR ALMS L 1:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 1:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 1:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 4:DIESEL TYPE: STANDARD NORMALLY CLOSED TANK #: 5 LIQUID SENSOR ALMS L 5:FUEL ALARM L 5:SENSOR OUT ALARM L 5:SHORT ALARM I79000 FEB 9, 2016 9:32 AM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 FEB 9, 2016 9:32 AM I72300 FEB 9, 2016 9:32 AM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 PS 7-8 VAPOR PRESSURE 02 FM 1-2 AIR FLOW METER 03 FM 3-4 AIR FLOW METER 04 FM 5-6 AIR FLOW METER 05 FM 7-8 AIR FLOW METER 06 FM 9-10 AIR FLOW METER 07 FM 11-12 AIR FLOW METER 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN I72A00 FEB 9, 2016 9:32 AM VACUUM SENSOR VOLUME DEVICE LABEL VOLUME IV4E00 FEB 9, 2016 9:32 AM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 FEB 9, 2016 9:32 AM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 FEB 9, 2016 9:32 AM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 VAPOR PROCESSOR TYPE NO VAPOR PROCESSOR IV4700 FEB 9, 2016 9:32 AM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 FEB 9, 2016 9:32 AM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 ACCEPT HIGH ORVR: NO IV4A00 FEB 9, 2016 9:32 AM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 33 01 01 BLEND3 02 34 02 01 BLEND3 03 35 03 02 BLEND3 04 01 04 02 BLEND3 05 03 05 03 BLEND3 06 00 06 03 BLEND3 07 07 07 04 BLEND3 08 04 08 04 BLEND3 09 05 09 05 BLEND3 10 08 10 05 BLEND3 11 06 11 06 BLEND3 12 02 12 06 BLEND3 IV4B00 FEB 9, 2016 9:32 AM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 00 03 02/06 03/06 09/06 xx/xx 01 02 02/04 03/04 09/04 xx/xx 02 06 02/12 03/12 09/12 xx/xx 03 03 02/05 03/05 09/05 xx/xx 04 04 02/08 03/08 09/08 xx/xx 05 05 02/09 03/09 09/09 xx/xx 06 06 02/11 03/11 09/11 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 05 02/10 03/10 09/10 xx/xx 33 01 02/01 03/01 09/01 xx/xx 34 01 02/02 03/02 09/02 xx/xx 35 02 02/03 03/03 09/03 xx/xx IV4900 FEB 9, 2016 9:32 AM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 FEB 9, 2016 9:32 AM ISD VERSION: 01.01 California Chevron Alarm Hist Before: Responses Received: I10200 FEB 9, 2016 9:35 AM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 509167 510690 2 4 PROBE / G.T. 163392 163935 3 4 PROBE / G.T. 163608 163913 4 INTERSTITIAL BD 200115 200400 5 INTERSTITIAL BD 9979989 202629 6 UNUSED 9961844 9854507 7 UNUSED 9970039 9832644 8 UNUSED 9956033 9841539 9 RELAY BOARD 14979 15014 10 STP SENSE BOARD 33191 33267 11 UNUSED 9967758 9844722 12 UNUSED 9971479 9829301 13 UNUSED 9959626 9838425 14 UNUSED 9960379 9823690 15 UNUSED 9969242 9840586 16 UNUSED 9964748 9819866 COMM 1 RS232 SERIAL BD 14958 14993 COMM 2 RS232 SERIAL BD 15084 15098 COMM 3 ELEC DISP INT. 101158 101040 COMM 4 UNUSED 9970810 9841210 COMM 5 SERIAL SAT BD 9969911 479975 COMM 6 UNUSED 9958685 9841771 I90200 FEB 9, 2016 9:35 AM SOFTWARE REVISION LEVEL VERSION 327.04 SOFTWARE# 346327-100-E CREATED - 07.02.06.10.28 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD PMC I11100 FEB 9, 2016 9:35 AM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 5 STP SUMP DIESEL STP FUEL ALARM CLEAR 2-03-16 2:27PM L 5 STP SUMP DIESEL STP FUEL ALARM ALARM 2-03-16 2:27PM L10 OTHER DIESEL FILL FUEL ALARM CLEAR 2-01-16 10:10AM L10 OTHER DIESEL FILL FUEL ALARM ALARM 1-31-16 12:20PM h12 OTHER FP12: BLEND3 DEGRD COLLECT FAIL CLEAR 12-30-15 11:47AM h12 OTHER FP12: BLEND3 DEGRD COLLECT FAIL ALARM 12-30-15 10:02AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 12-02-15 5:04PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 12-01-15 10:27AM OTHER ISD VAPOR LEAK FAIL CLEAR 9-06-15 10:58AM OTHER ISD VAPOR LEAK FAIL ALARM 9-06-15 10:03AM OTHER ISD VAPOR LEAK FAIL CLEAR 8-14-15 10:45AM OTHER ISD VAPOR LEAK FAIL ALARM 8-14-15 10:03AM OTHER ISD VAPOR LEAK FAIL CLEAR 7-20-15 11:16AM OTHER ISD VAPOR LEAK FAIL ALARM 7-20-15 10:03AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 6-27-15 4:48PM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 6-26-15 4:58PM L 6 OTHER UNL NORTH FILL FUEL ALARM CLEAR 5-25-15 3:17PM L 6 OTHER UNL NORTH FILL FUEL ALARM ALARM 5-22-15 8:58AM L 5 STP SUMP DIESEL STP FUEL ALARM CLEAR 5-07-15 8:19AM L 5 STP SUMP DIESEL STP FUEL ALARM ALARM 5-07-15 8:19AM L 2 OTHER SUPREME STP SENSOR OUT ALARM CLEAR 4-11-15 10:36AM L 8 OTHER UNL SIPHON FILL SENSOR OUT ALARM CLEAR 4-11-15 10:36AM L 7 OTHER SUPREME FILL SENSOR OUT ALARM CLEAR 4-11-15 10:36AM L 6 OTHER UNL NORTH FILL SENSOR OUT ALARM CLEAR 4-11-15 10:36AM L 5 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 4-11-15 10:36AM L 3 OTHER UNLEADED SIPHON STP SENSOR OUT ALARM CLEAR 4-11-15 10:36AM L 1 OTHER UNLEADED NORTH STP SENSOR OUT ALARM CLEAR 4-11-15 10:36AM L 4 OTHER UNLEADED SOUTH STP SENSOR OUT ALARM CLEAR 4-11-15 10:36AM L 6 OTHER UNL NORTH FILL SENSOR OUT ALARM ALARM 4-11-15 10:36AM L 3 OTHER UNLEADED SIPHON STP SENSOR OUT ALARM ALARM 4-11-15 10:36AM L 2 OTHER SUPREME STP SENSOR OUT ALARM ALARM 4-11-15 10:35AM L 8 OTHER UNL SIPHON FILL SENSOR OUT ALARM ALARM 4-11-15 10:35AM L 7 OTHER SUPREME FILL SENSOR OUT ALARM ALARM 4-11-15 10:35AM L 5 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 4-11-15 10:35AM L 1 OTHER UNLEADED NORTH STP SENSOR OUT ALARM ALARM 4-11-15 10:35AM L 4 OTHER UNLEADED SOUTH STP SENSOR OUT ALARM ALARM 4-11-15 10:35AM L12 ANNULAR SUPREME ANNULAR FUEL ALARM CLEAR 4-11-15 10:35AM L14 ANNULAR UNL SOUTH ANNULAR FUEL ALARM CLEAR 4-11-15 10:35AM L10 OTHER DIESEL FILL SENSOR OUT ALARM CLEAR 4-11-15 10:35AM L13 ANNULAR UNL SIPHON ANNULAR FUEL ALARM CLEAR 4-11-15 10:35AM L11 ANNULAR UNL ANNULAR SENSOR OUT ALARM CLEAR 4-11-15 10:35AM L 9 OTHER UNL SOUTH FILL SENSOR OUT ALARM CLEAR 4-11-15 10:35AM L15 ANNULAR DIESEL ANNULAR FUEL ALARM CLEAR 4-11-15 10:35AM L12 ANNULAR SUPREME ANNULAR FUEL ALARM ALARM 4-11-15 10:35AM L11 ANNULAR UNL ANNULAR SENSOR OUT ALARM ALARM 4-11-15 10:35AM L10 OTHER DIESEL FILL SENSOR OUT ALARM ALARM 4-11-15 10:34AM L15 ANNULAR DIESEL ANNULAR FUEL ALARM ALARM 4-11-15 10:34AM L 9 OTHER UNL SOUTH FILL SENSOR OUT ALARM ALARM 4-11-15 10:34AM L14 ANNULAR UNL SOUTH ANNULAR FUEL ALARM ALARM 4-11-15 10:34AM L13 ANNULAR UNL SIPHON ANNULAR FUEL ALARM ALARM 4-11-15 10:34AM I11200 FEB 9, 2016 9:35 AM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME OTHER ISD GROSS PRES WARN CLEAR 2-03-16 1:56PM SYSTEM PRINTER ERROR CLEAR 2-01-16 10:04AM SYSTEM PAPER OUT CLEAR 2-01-16 10:04AM SYSTEM PRINTER ERROR ALARM 2-01-16 10:04AM SYSTEM PAPER OUT ALARM 2-01-16 10:04AM OTHER ISD GROSS PRES WARN ALARM 2-01-16 10:02AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN CLEAR 2-01-16 10:00AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN ALARM 1-30-16 10:02AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN CLEAR 1-29-16 10:00AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN ALARM 1-28-16 10:01AM OTHER ISD GROSS PRES WARN CLEAR 1-26-16 8:35AM OTHER ISD GROSS PRES WARN ALARM 1-25-16 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 1-24-16 10:00AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 1-22-16 10:01AM OTHER ISD GROSS PRES WARN CLEAR 1-19-16 8:11AM OTHER ISD GROSS PRES WARN ALARM 1-15-16 10:02AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN CLEAR 1-14-16 10:00AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN ALARM 1-13-16 10:01AM OTHER ISD GROSS PRES WARN CLEAR 1-08-16 12:11PM h 4 OTHER FP4: BLEND3 GROSS COLLECT WARN CLEAR 1-06-16 10:00AM OTHER ISD GROSS PRES WARN ALARM 1-05-16 10:01AM h 4 OTHER FP4: BLEND3 GROSS COLLECT WARN ALARM 1-05-16 10:01AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 12-30-15 10:00AM OTHER ISD GROSS PRES WARN CLEAR 12-29-15 11:04AM T 1 TANK UNLEADED NORTH INVALID FUEL LEVEL CLEAR 12-24-15 2:22PM T 1 TANK UNLEADED NORTH INVALID FUEL LEVEL ALARM 12-24-15 11:43AM OTHER ISD GROSS PRES WARN ALARM 12-24-15 10:01AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 12-22-15 10:01AM OTHER ISD GROSS PRES WARN CLEAR 12-17-15 12:16PM OTHER ISD GROSS PRES WARN ALARM 12-16-15 10:01AM SYSTEM PRINTER ERROR CLEAR 12-14-15 4:33PM SYSTEM PAPER OUT CLEAR 12-14-15 4:33PM SYSTEM PRINTER ERROR ALARM 12-14-15 4:28PM SYSTEM PAPER OUT ALARM 12-14-15 4:28PM OTHER ISD GROSS PRES WARN CLEAR 12-09-15 10:49AM OTHER ISD GROSS PRES WARN ALARM 12-07-15 10:02AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 12-04-15 10:00AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 12-03-15 10:02AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 12-02-15 10:00AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 12-01-15 10:02AM OTHER ISD GROSS PRES WARN CLEAR 11-30-15 5:03PM OTHER ISD GROSS PRES WARN ALARM 11-29-15 10:02AM OTHER ISD GROSS PRES WARN CLEAR 11-23-15 7:59AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 11-22-15 10:00AM OTHER ISD GROSS PRES WARN ALARM 11-20-15 10:01AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 11-18-15 10:01AM SYSTEM PRINTER ERROR CLEAR 11-17-15 5:07PM SYSTEM PAPER OUT CLEAR 11-17-15 5:07PM SYSTEM PRINTER ERROR ALARM 11-17-15 5:01PM SYSTEM PAPER OUT ALARM 11-17-15 5:01PM I20600 FEB 9, 2016 9:35 AM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 TANK ALARM HISTORY TANK 1 UNLEADED NORTH LEAK ALARM JUN 2, 2014 1:23 PM INVALID FUEL LEVEL DEC 24, 2015 11:43 AM FEB 6, 2014 7:31 AM FEB 5, 2014 8:23 PM PROBE OUT FEB 3, 2014 11:00 AM TANK 2 SUPREME LEAK ALARM JUN 2, 2014 12:53 PM SUDDEN LOSS ALARM JUN 2, 2014 12:07 PM TANK 3 UNLEADED SIPHON LEAK ALARM JUN 2, 2014 12:53 PM PROBE OUT FEB 3, 2014 11:07 AM TANK 4 UNLEADED SOUTH LEAK ALARM JUN 2, 2014 12:23 PM OVERFILL ALARM AUG 23, 2013 2:44 AM PROBE OUT FEB 3, 2014 11:09 AM TANK 5 DIESEL LEAK ALARM JUN 2, 2014 7:53 PM SUDDEN LOSS ALARM JUN 2, 2014 7:17 PM INVALID FUEL LEVEL MAY 13, 2014 7:52 PM I38200 FEB 9, 2016 9:35 AM I30200 FEB 9, 2016 9:35 AM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNLEADED NORTH STP APR 11, 2015 10:35 AM SENSOR OUT ALARM APR 11, 2015 10:30 AM FUEL ALARM APR 11, 2015 9:59 AM FUEL ALARM 2 SUPREME STP APR 11, 2015 10:35 AM SENSOR OUT ALARM APR 11, 2015 10:30 AM FUEL ALARM APR 11, 2015 10:05 AM SENSOR OUT ALARM 3 UNLEADED SIPHON STP APR 11, 2015 10:36 AM SENSOR OUT ALARM APR 11, 2015 10:31 AM FUEL ALARM APR 2, 2015 10:38 AM FUEL ALARM 4 UNLEADED SOUTH STP APR 11, 2015 10:35 AM SENSOR OUT ALARM APR 11, 2015 10:31 AM FUEL ALARM APR 2, 2015 10:38 AM FUEL ALARM 5 DIESEL STP FEB 3, 2016 2:27 PM FUEL ALARM MAY 7, 2015 8:19 AM FUEL ALARM APR 11, 2015 10:35 AM SENSOR OUT ALARM 6 UNL NORTH FILL MAY 22, 2015 8:58 AM FUEL ALARM APR 11, 2015 10:36 AM SENSOR OUT ALARM APR 11, 2015 10:32 AM FUEL ALARM 7 SUPREME FILL APR 11, 2015 10:35 AM SENSOR OUT ALARM APR 11, 2015 9:42 AM SENSOR OUT ALARM APR 11, 2015 9:33 AM FUEL ALARM 8 UNL SIPHON FILL APR 11, 2015 10:35 AM SENSOR OUT ALARM APR 11, 2015 10:33 AM FUEL ALARM APR 11, 2015 8:59 AM FUEL ALARM 9 UNL SOUTH FILL APR 11, 2015 10:34 AM SENSOR OUT ALARM APR 2, 2015 10:40 AM FUEL ALARM APR 2, 2015 10:08 AM FUEL ALARM 10 DIESEL FILL JAN 31, 2016 12:20 PM FUEL ALARM APR 11, 2015 10:34 AM SENSOR OUT ALARM APR 10, 2015 11:23 AM SENSOR OUT ALARM 11 UNL ANNULAR APR 11, 2015 10:35 AM SENSOR OUT ALARM MAR 4, 2015 3:59 PM FUEL ALARM MAR 4, 2015 3:58 PM FUEL ALARM 12 SUPREME ANNULAR APR 11, 2015 10:35 AM FUEL ALARM APR 11, 2015 9:49 AM FUEL ALARM APR 11, 2015 9:27 AM FUEL ALARM 13 UNL SIPHON ANNULAR APR 11, 2015 10:34 AM FUEL ALARM MAR 4, 2015 1:32 PM FUEL ALARM MAR 4, 2015 1:32 PM FUEL ALARM 14 UNL SOUTH ANNULAR APR 11, 2015 10:34 AM FUEL ALARM MAR 4, 2015 4:03 PM FUEL ALARM MAR 4, 2015 4:02 PM SETUP DATA WARNING 15 DIESEL ANNULAR APR 11, 2015 10:34 AM FUEL ALARM APR 2, 2015 10:31 AM FUEL ALARM APR 2, 2015 10:06 AM FUEL ALARM I31600 FEB 9, 2016 9:35 AM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 7-8 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 6 FM 9-10 7 FM 11-12 I40200 FEB 9, 2016 9:35 AM I40300 FEB 9, 2016 9:35 AM I34200 FEB 9, 2016 9:35 AM I34700 FEB 9, 2016 9:35 AM IV0100 FEB 9, 2016 9:35 AM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.01 VAPOR PROCESSOR TYPE: NO VAPOR PROCESSOR OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% STAGE I TRANSFERS: 0 of 0 NOTEST EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 16-02-03 10:02:02 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.98 16-02-02 10:01:59 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.98 16-02-01 10:02:12 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 4.03 16-01-31 10:02:13 A/L RATIO DEGRADATION FP10 BLEND3 0.79 16-01-30 10:02:17 A/L RATIO DEGRADATION FP10 BLEND3 0.80 16-01-28 10:01:59 A/L RATIO DEGRADATION FP10 BLEND3 0.80 16-01-25 10:01:10 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.95 16-01-23 10:01:09 A/L RATIO DEGRADATION FP 4 BLEND3 0.80 16-01-22 10:01:18 A/L RATIO DEGRADATION FP 4 BLEND3 0.81 16-01-18 10:02:11 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.95 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 15-12-30 10:02:47 A/L RATIO DEGRADATION FP12 BLEND3 0.79 15-09-06 10:03:08 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.91 15-08-14 10:03:46 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.74 15-07-20 10:03:34 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 8.87 14-08-25 10:02:53 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 14-08-25 10:02:53 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 13-09-16 10:03:28 A/L RATIO DEGRADATION FP 2 BLEND3 0.69 13-05-12 10:01:22 A/L RATIO GROSS BLOCKAGE FP11 BLEND3 BLKD 13-05-12 10:01:22 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 2.05 13-05-11 10:01:14 A/L RATIO GROSS BLOCKAGE FP12 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 16-02-03 13:56:51 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 16-01-26 08:35:36 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 16-01-19 08:11:46 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 16-01-08 12:11:53 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 15-12-30 11:47:57 COLLECTION TEST HH12 GRADE TEST MANUALLY CLEARED 15-12-30 11:17:40 PUMPS MANUALLY RE-ENABLED 15-12-30 10:02:47 A/L RATIO GROSS DEGRADATION DISABLED FP 12 BLEND3 15-12-29 11:04:41 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 15-12-17 12:16:37 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 15-12-09 10:49:04 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED California Chevron Alarm Hist After: Responses Received: I10200 FEB 9, 2016 7:32 PM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 509167 509589 2 4 PROBE / G.T. 163392 163804 3 4 PROBE / G.T. 163608 163890 4 INTERSTITIAL BD 200115 200462 5 INTERSTITIAL BD 9979989 202496 6 UNUSED 9961844 9846316 7 UNUSED 9970039 9841993 8 UNUSED 9956033 9844404 9 RELAY BOARD 14979 15014 10 STP SENSE BOARD 33191 33267 11 UNUSED 9967758 9835596 12 UNUSED 9971479 9844054 13 UNUSED 9959626 9841020 14 UNUSED 9960379 9837612 15 UNUSED 9969242 9842641 16 UNUSED 9964748 9834661 COMM 1 RS232 SERIAL BD 14958 14972 COMM 2 RS232 SERIAL BD 15084 15077 COMM 3 ELEC DISP INT. 101158 101209 COMM 4 UNUSED 9970810 9834806 COMM 5 SERIAL SAT BD 9969911 480004 COMM 6 UNUSED 9958685 9829299 I90200 FEB 9, 2016 7:32 PM SOFTWARE REVISION LEVEL VERSION 327.04 SOFTWARE# 346327-100-E CREATED - 07.02.06.10.28 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD PMC I11100 FEB 9, 2016 7:32 PM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L11 ANNULAR UNL ANNULAR FUEL ALARM CLEAR 2-09-16 5:51PM L11 ANNULAR UNL ANNULAR FUEL ALARM ALARM 2-09-16 5:49PM L11 ANNULAR UNL ANNULAR FUEL ALARM CLEAR 2-09-16 5:46PM L11 ANNULAR UNL ANNULAR FUEL ALARM ALARM 2-09-16 5:45PM L11 ANNULAR UNL ANNULAR FUEL ALARM CLEAR 2-09-16 5:45PM L11 ANNULAR UNL ANNULAR FUEL ALARM ALARM 2-09-16 5:44PM L11 ANNULAR UNL ANNULAR FUEL ALARM CLEAR 2-09-16 5:44PM L11 ANNULAR UNL ANNULAR FUEL ALARM ALARM 2-09-16 5:43PM L11 ANNULAR UNL ANNULAR FUEL ALARM CLEAR 2-09-16 5:42PM L11 ANNULAR UNL ANNULAR FUEL ALARM ALARM 2-09-16 5:42PM L11 ANNULAR UNL ANNULAR FUEL ALARM CLEAR 2-09-16 5:40PM L15 ANNULAR DIESEL ANNULAR FUEL ALARM CLEAR 2-09-16 5:39PM L11 ANNULAR UNL ANNULAR FUEL ALARM ALARM 2-09-16 5:38PM L15 ANNULAR DIESEL ANNULAR SENSOR OUT ALARM CLEAR 2-09-16 5:38PM L15 ANNULAR DIESEL ANNULAR FUEL ALARM ALARM 2-09-16 5:38PM L15 ANNULAR DIESEL ANNULAR SENSOR OUT ALARM ALARM 2-09-16 5:37PM L15 ANNULAR DIESEL ANNULAR FUEL ALARM CLEAR 2-09-16 5:37PM L15 ANNULAR DIESEL ANNULAR SENSOR OUT ALARM CLEAR 2-09-16 5:37PM L15 ANNULAR DIESEL ANNULAR FUEL ALARM ALARM 2-09-16 5:37PM L15 ANNULAR DIESEL ANNULAR SENSOR OUT ALARM ALARM 2-09-16 5:37PM L15 ANNULAR DIESEL ANNULAR FUEL ALARM CLEAR 2-09-16 5:37PM L11 ANNULAR UNL ANNULAR FUEL ALARM CLEAR 2-09-16 5:36PM L11 ANNULAR UNL ANNULAR FUEL ALARM ALARM 2-09-16 5:36PM L11 ANNULAR UNL ANNULAR FUEL ALARM CLEAR 2-09-16 5:35PM L15 ANNULAR DIESEL ANNULAR FUEL ALARM ALARM 2-09-16 5:31PM L13 ANNULAR UNL SIPHON ANNULAR FUEL ALARM CLEAR 2-09-16 5:30PM L13 ANNULAR UNL SIPHON ANNULAR FUEL ALARM ALARM 2-09-16 5:28PM L13 ANNULAR UNL SIPHON ANNULAR FUEL ALARM CLEAR 2-09-16 5:27PM L13 ANNULAR UNL SIPHON ANNULAR FUEL ALARM ALARM 2-09-16 5:27PM L11 ANNULAR UNL ANNULAR FUEL ALARM ALARM 2-09-16 5:27PM L11 ANNULAR UNL ANNULAR FUEL ALARM CLEAR 2-09-16 5:26PM L11 ANNULAR UNL ANNULAR FUEL ALARM ALARM 2-09-16 5:25PM L11 ANNULAR UNL ANNULAR FUEL ALARM CLEAR 2-09-16 4:43PM L13 ANNULAR UNL SIPHON ANNULAR FUEL ALARM CLEAR 2-09-16 4:41PM T 4 TANK UNLEADED SOUTH MAX PRODUCT ALARM CLEAR 2-09-16 4:38PM L13 ANNULAR UNL SIPHON ANNULAR FUEL ALARM ALARM 2-09-16 4:37PM L13 ANNULAR UNL SIPHON ANNULAR FUEL ALARM CLEAR 2-09-16 4:35PM L13 ANNULAR UNL SIPHON ANNULAR FUEL ALARM ALARM 2-09-16 4:34PM L15 ANNULAR DIESEL ANNULAR FUEL ALARM CLEAR 2-09-16 4:02PM L11 ANNULAR UNL ANNULAR FUEL ALARM ALARM 2-09-16 3:58PM L13 ANNULAR UNL SIPHON ANNULAR FUEL ALARM CLEAR 2-09-16 3:50PM L13 ANNULAR UNL SIPHON ANNULAR FUEL ALARM ALARM 2-09-16 3:50PM L15 ANNULAR DIESEL ANNULAR FUEL ALARM ALARM 2-09-16 3:49PM T 4 TANK UNLEADED SOUTH MAX PRODUCT ALARM ALARM 2-09-16 3:46PM L13 ANNULAR UNL SIPHON ANNULAR FUEL ALARM CLEAR 2-09-16 3:35PM L13 ANNULAR UNL SIPHON ANNULAR FUEL ALARM ALARM 2-09-16 3:35PM L13 ANNULAR UNL SIPHON ANNULAR FUEL ALARM CLEAR 2-09-16 3:33PM L16 OTHER DIESEL FILL FUEL ALARM CLEAR 2-09-16 3:32PM L13 ANNULAR UNL SIPHON ANNULAR SENSOR OUT ALARM CLEAR 2-09-16 3:26PM L13 ANNULAR UNL SIPHON ANNULAR FUEL ALARM ALARM 2-09-16 3:26PM I11200 FEB 9, 2016 7:32 PM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 4 TANK UNLEADED SOUTH HIGH PRODUCT ALARM CLEAR 2-09-16 4:38PM T 4 TANK UNLEADED SOUTH HIGH PRODUCT ALARM ALARM 2-09-16 3:46PM T 4 TANK UNLEADED SOUTH HIGH PRODUCT ALARM CLEAR 2-09-16 2:43PM T 4 TANK UNLEADED SOUTH HIGH PRODUCT ALARM ALARM 2-09-16 2:20PM T 1 TANK UNLEADED NORTH HIGH PRODUCT ALARM CLEAR 2-09-16 2:17PM T 1 TANK UNLEADED NORTH HIGH PRODUCT ALARM ALARM 2-09-16 2:00PM L14 ANNULAR UNL SOUTH ANNULAR SETUP DATA WARNING CLEAR 2-09-16 1:47PM L15 ANNULAR DIESEL ANNULAR SETUP DATA WARNING CLEAR 2-09-16 1:46PM L14 ANNULAR UNL SOUTH ANNULAR SETUP DATA WARNING ALARM 2-09-16 1:39PM L14 ANNULAR UNL SOUTH ANNULAR SETUP DATA WARNING CLEAR 2-09-16 1:39PM L14 ANNULAR UNL SOUTH ANNULAR SETUP DATA WARNING ALARM 2-09-16 1:38PM L14 ANNULAR UNL SOUTH ANNULAR SETUP DATA WARNING CLEAR 2-09-16 1:38PM L14 ANNULAR UNL SOUTH ANNULAR SETUP DATA WARNING ALARM 2-09-16 1:38PM L14 ANNULAR UNL SOUTH ANNULAR SETUP DATA WARNING CLEAR 2-09-16 1:38PM L14 ANNULAR UNL SOUTH ANNULAR SETUP DATA WARNING ALARM 2-09-16 1:37PM L15 ANNULAR DIESEL ANNULAR SETUP DATA WARNING ALARM 2-09-16 1:36PM T 5 TANK DIESEL INVALID FUEL LEVEL CLEAR 2-09-16 10:33AM T 5 TANK DIESEL INVALID FUEL LEVEL ALARM 2-09-16 10:33AM T 3 TANK UNLEADED SIPHON LOW TEMP WARNING CLEAR 2-09-16 10:30AM T 3 TANK UNLEADED SIPHON LOW TEMP WARNING ALARM 2-09-16 10:30AM OTHER ISD GROSS PRES WARN CLEAR 2-03-16 1:56PM SYSTEM PRINTER ERROR CLEAR 2-01-16 10:04AM SYSTEM PAPER OUT CLEAR 2-01-16 10:04AM SYSTEM PRINTER ERROR ALARM 2-01-16 10:04AM SYSTEM PAPER OUT ALARM 2-01-16 10:04AM OTHER ISD GROSS PRES WARN ALARM 2-01-16 10:02AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN CLEAR 2-01-16 10:00AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN ALARM 1-30-16 10:02AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN CLEAR 1-29-16 10:00AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN ALARM 1-28-16 10:01AM OTHER ISD GROSS PRES WARN CLEAR 1-26-16 8:35AM OTHER ISD GROSS PRES WARN ALARM 1-25-16 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 1-24-16 10:00AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 1-22-16 10:01AM OTHER ISD GROSS PRES WARN CLEAR 1-19-16 8:11AM OTHER ISD GROSS PRES WARN ALARM 1-15-16 10:02AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN CLEAR 1-14-16 10:00AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN ALARM 1-13-16 10:01AM OTHER ISD GROSS PRES WARN CLEAR 1-08-16 12:11PM h 4 OTHER FP4: BLEND3 GROSS COLLECT WARN CLEAR 1-06-16 10:00AM OTHER ISD GROSS PRES WARN ALARM 1-05-16 10:01AM h 4 OTHER FP4: BLEND3 GROSS COLLECT WARN ALARM 1-05-16 10:01AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 12-30-15 10:00AM OTHER ISD GROSS PRES WARN CLEAR 12-29-15 11:04AM T 1 TANK UNLEADED NORTH INVALID FUEL LEVEL CLEAR 12-24-15 2:22PM T 1 TANK UNLEADED NORTH INVALID FUEL LEVEL ALARM 12-24-15 11:43AM OTHER ISD GROSS PRES WARN ALARM 12-24-15 10:01AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 12-22-15 10:01AM OTHER ISD GROSS PRES WARN CLEAR 12-17-15 12:16PM OTHER ISD GROSS PRES WARN ALARM 12-16-15 10:01AM I20600 FEB 9, 2016 7:32 PM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 TANK ALARM HISTORY TANK 1 UNLEADED NORTH LEAK ALARM JUN 2, 2014 1:23 PM HIGH PRODUCT ALARM FEB 9, 2016 2:00 PM INVALID FUEL LEVEL DEC 24, 2015 11:43 AM FEB 6, 2014 7:31 AM FEB 5, 2014 8:23 PM PROBE OUT FEB 9, 2016 10:08 AM FEB 3, 2014 11:00 AM MAX PRODUCT ALARM FEB 9, 2016 2:00 PM TANK 2 SUPREME LEAK ALARM JUN 2, 2014 12:53 PM SUDDEN LOSS ALARM JUN 2, 2014 12:07 PM PROBE OUT FEB 9, 2016 10:26 AM TANK 3 UNLEADED SIPHON LEAK ALARM JUN 2, 2014 12:53 PM PROBE OUT FEB 9, 2016 10:29 AM FEB 3, 2014 11:07 AM LOW TEMP WARNING FEB 9, 2016 10:30 AM TANK 4 UNLEADED SOUTH LEAK ALARM JUN 2, 2014 12:23 PM OVERFILL ALARM AUG 23, 2013 2:44 AM HIGH PRODUCT ALARM FEB 9, 2016 3:46 PM FEB 9, 2016 2:20 PM PROBE OUT FEB 9, 2016 10:30 AM FEB 3, 2014 11:09 AM MAX PRODUCT ALARM FEB 9, 2016 3:46 PM FEB 9, 2016 2:20 PM TANK 5 DIESEL LEAK ALARM JUN 2, 2014 7:53 PM SUDDEN LOSS ALARM JUN 2, 2014 7:17 PM INVALID FUEL LEVEL FEB 9, 2016 10:33 AM MAY 13, 2014 7:52 PM PROBE OUT FEB 9, 2016 10:31 AM I38200 FEB 9, 2016 7:32 PM I30200 FEB 9, 2016 7:32 PM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNLEADED NORTH STP FEB 9, 2016 10:13 AM FUEL ALARM FEB 9, 2016 10:02 AM SENSOR OUT ALARM APR 11, 2015 10:35 AM SENSOR OUT ALARM 2 SUPREME STP FEB 9, 2016 10:14 AM FUEL ALARM FEB 9, 2016 10:02 AM SENSOR OUT ALARM APR 11, 2015 10:35 AM SENSOR OUT ALARM 3 UNLEADED SIPHON STP FEB 9, 2016 10:15 AM FUEL ALARM FEB 9, 2016 10:02 AM SENSOR OUT ALARM APR 11, 2015 10:36 AM SENSOR OUT ALARM 4 UNLEADED SOUTH STP FEB 9, 2016 10:17 AM FUEL ALARM FEB 9, 2016 10:02 AM SENSOR OUT ALARM APR 11, 2015 10:35 AM SENSOR OUT ALARM 5 DIESEL STP FEB 9, 2016 10:17 AM FUEL ALARM FEB 9, 2016 10:02 AM SENSOR OUT ALARM FEB 3, 2016 2:27 PM FUEL ALARM 6 UNL NORTH FILL FEB 9, 2016 10:24 AM FUEL ALARM FEB 9, 2016 10:02 AM SENSOR OUT ALARM MAY 22, 2015 8:58 AM FUEL ALARM 7 SUPREME FILL FEB 9, 2016 10:24 AM FUEL ALARM FEB 9, 2016 10:02 AM SENSOR OUT ALARM APR 11, 2015 10:35 AM SENSOR OUT ALARM 8 UNL SIPHON FILL FEB 9, 2016 1:14 PM FUEL ALARM FEB 9, 2016 10:24 AM FUEL ALARM FEB 9, 2016 10:23 AM FUEL ALARM 9 UNL SOUTH FILL FEB 9, 2016 10:21 AM FUEL ALARM FEB 9, 2016 10:02 AM SENSOR OUT ALARM APR 11, 2015 10:34 AM SENSOR OUT ALARM 10 DIESEL FILL FEB 9, 2016 10:19 AM FUEL ALARM FEB 9, 2016 10:02 AM SENSOR OUT ALARM JAN 31, 2016 12:20 PM FUEL ALARM 11 UNL ANNULAR FEB 9, 2016 5:49 PM FUEL ALARM FEB 9, 2016 5:45 PM FUEL ALARM FEB 9, 2016 5:44 PM FUEL ALARM 12 SUPREME ANNULAR FEB 9, 2016 1:17 PM FUEL ALARM FEB 9, 2016 10:52 AM FUEL ALARM FEB 9, 2016 10:51 AM FUEL ALARM 13 UNL SIPHON ANNULAR FEB 9, 2016 5:28 PM FUEL ALARM FEB 9, 2016 5:27 PM FUEL ALARM FEB 9, 2016 4:37 PM FUEL ALARM 14 UNL SOUTH ANNULAR FEB 9, 2016 1:39 PM SETUP DATA WARNING FEB 9, 2016 1:38 PM SETUP DATA WARNING FEB 9, 2016 1:38 PM SETUP DATA WARNING 15 DIESEL ANNULAR FEB 9, 2016 5:38 PM FUEL ALARM FEB 9, 2016 5:37 PM SENSOR OUT ALARM FEB 9, 2016 5:37 PM FUEL ALARM I31600 FEB 9, 2016 7:32 PM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 7-8 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 6 FM 9-10 7 FM 11-12 I40200 FEB 9, 2016 7:32 PM I40300 FEB 9, 2016 7:32 PM I34200 FEB 9, 2016 7:32 PM I34700 FEB 9, 2016 7:32 PM IV0100 FEB 9, 2016 7:32 PM 204121 CALIFORNIA CH 4100 CALIFORNIA AVE BKRSFLD CA 93309 661-336-0263 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.01 VAPOR PROCESSOR TYPE: NO VAPOR PROCESSOR OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME : 99% STAGE I TRANSFERS: 0 of 0 NOTEST EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 16-02-03 10:02:02 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.98 16-02-02 10:01:59 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.98 16-02-01 10:02:12 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 4.03 16-01-31 10:02:13 A/L RATIO DEGRADATION FP10 BLEND3 0.79 16-01-30 10:02:17 A/L RATIO DEGRADATION FP10 BLEND3 0.80 16-01-28 10:01:59 A/L RATIO DEGRADATION FP10 BLEND3 0.80 16-01-25 10:01:10 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.95 16-01-23 10:01:09 A/L RATIO DEGRADATION FP 4 BLEND3 0.80 16-01-22 10:01:18 A/L RATIO DEGRADATION FP 4 BLEND3 0.81 16-01-18 10:02:11 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.95 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 15-12-30 10:02:47 A/L RATIO DEGRADATION FP12 BLEND3 0.79 15-09-06 10:03:08 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.91 15-08-14 10:03:46 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.74 15-07-20 10:03:34 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 8.87 14-08-25 10:02:53 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 14-08-25 10:02:53 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 13-09-16 10:03:28 A/L RATIO DEGRADATION FP 2 BLEND3 0.69 13-05-12 10:01:22 A/L RATIO GROSS BLOCKAGE FP11 BLEND3 BLKD 13-05-12 10:01:22 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 2.05 13-05-11 10:01:14 A/L RATIO GROSS BLOCKAGE FP12 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 16-02-09 10:02:26 READINESS ISD:PP EVR:PP ISD & EVR READY 16-02-09 10:01:04 READINESS ISD:PP EVR:NN EVR READINESS PENDING 16-02-09 10:01:04 ISD STARTUP 16-02-09 10:00:31 ISD SHUTDOWN 16-02-03 13:56:51 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 16-01-26 08:35:36 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 16-01-19 08:11:46 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 16-01-08 12:11:53 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 15-12-30 11:47:57 COLLECTION TEST HH12 GRADE TEST MANUALLY CLEARED 15-12-30 11:17:40 PUMPS MANUALLY RE-ENABLED SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator forsubmittal to the local regulatory agency. 1.FACILITY INFORMATION Facility Name:Date of Testing: Facility Address: Facility Contact:Phone: Date Local Agency Was Notified of Testing : Name of Local Agency Inspector (if present during testing): 2.TESTING CONTRACTOR INFORMATION Company Name:Confidence UST Services, Inc. Technician Conducting Test: Credentials1:CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s):CSLB#804904 ICC# 3.SPILL BUCKET TESTING INFORMATION Test Method Used:Hydrostatic Vacuum Other Test Equipment Used:Lake Test Equipment Resolution:0.0625” Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1234 Bucket Installation Type: Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test: Test Start Time (TI): Initial Reading (RI): Test End Time (TF): Final Reading (RF): Test Duration (TF – TI): Change in Reading (RF -RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Comments –(include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician’s Signature:________________________________________________ Date:_________ 1 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. Samco#4 02/09/2016 4100CaliforniaAvenue SamJouda Regular-No 12.00" 12.75" 5min. 9:30 am 12.00" 10:30 am 12.00" 1hour 0.00" 0.0625" Regular-So 12.00" 14.00" 5min. 9:30 am 13.50" 10:30 am 13.50" 1hour 0.00" 0.0625"0.0625" Regular-Siphon 12.00" 13.25" 5min. 9:30 am 13.25" 10:30 am 13.25" 1hour 0.00" Super 12.00" 13.50" 5min. 9:30 am 13.25" 10:30 am 13.25" 1hour 0.00" 0.0625" 02/09/2016 , Bakersfield, CA 93309 (661) 393-7000 1/12/2016 Dustin Reese 8216722-UT X Shane Gardner SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator forsubmittal to the local regulatory agency. 1.FACILITY INFORMATION Facility Name:Date of Testing: Facility Address: Facility Contact:Phone: Date Local Agency Was Notified of Testing : Name of Local Agency Inspector (if present during testing): 2.TESTING CONTRACTOR INFORMATION Company Name:Confidence UST Services, Inc. Technician Conducting Test: Credentials1:CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s):CSLB#804904 ICC# 3.SPILL BUCKET TESTING INFORMATION Test Method Used:Hydrostatic Vacuum Other Test Equipment Used:Lake Test Equipment Resolution:0.0625” Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1234 Bucket Installation Type: Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test: Test Start Time (TI): Initial Reading (RI): Test End Time (TF): Final Reading (RF): Test Duration (TF – TI): Change in Reading (RF -RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Comments –(include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician’s Signature:________________________________________________ Date:_________ 1 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent.     '8VWLQ5HHVH ; 87  Samco#4 4100CaliforniaAvenue,Bakersfield,CA93309 SamJouda Shane Gardner Dustin Reese 8216722-UT Diesel 12.00" 15.00" 5min. 9:30 am 12.50" 9:45 am 11.00" 1hour 1.50" 0.0625" The Diesel spill bucket is a fail and will need to be replaced