Loading...
HomeMy WebLinkAboutFire Safety Insp 9-14-16DISTRICT " BLOCK NO. DATE : FEE' FACILITY ADDRESS CITY, STATE,:ZIP , k �? O; r t t" FACILITY NAME a_.f .M,�-AaN.�A-GER'S NAME P%+ F9.' PH NO. _ r BUSINESS OWNER'S NAME AND ADDRESS CITY, STATE, ZIP ' trre I 1 PH NO.. - BILL TO: (IF DIFFERENT FROM, ABOVE) NAME, ADDRESS CITY, :STATE, ZIP, PH NO. OCC TYPE, OCC LOAD NO. OF FLOORS. HIGH RISE BLDG NO RISER DATE . . YES r CORRECT ALL VIOLATIONS. VIOLATION REQUIREMENTS CHECKED BELOW NO: 1 Remove and safely dispose of all hazardous refuse and dry. vegetation on the above. premises (CFC COMBUSTIBLE WASTE % DRY VEGETATION 304.1. '1.) 2 L Provide non - combustible. containers with tight fitting lids for - the- storag.e, of coinbustible.waste and rubbish. pending its `s.afe d1sposal. (CFC 304.3;2) ,Note: applies to containers. over 40 gallons: . COMBUSTIBLE. STORAGE 3 :.. Relocate combustible storage to provide at least 3. -feet clearance around motor fuse-box/fire door (CFC ` 605.3) . 4 Relocate fire extinguishers) so that they will -be in a conspicuous - location, hanging on brackets with the ;. top to the extinguisher not more than. 5 feet..a.bove the-floor.. (CFC 906.5 &.9:06.9) .' EXTINGUISHERS 5 Provide and install (amount) _____ approved (type. &.size) __ __ __ _ portable fire extinguisher to ,be immediately. accessible for. use in (area) ___ ____________ __ ____ __ ___ (CFC TABLE: 9063(l)). 6 Re- charge a.11 fire extinguis.he:rs.. Fire extinguishers shall be serviced at least once each year:, and %or -after each use; by a person having a valid -license or certificate. '(CFC. 9.0'6.2) : 7 P..rovide..and maintain "EXIT ";sign(s) with letters 6, or more inches in height over each required exit SIGNS . (door/window) to fire escape:. (CFC 101.1) g Provide and maintain appropriate numbers on a: contrasting .background, and Visible from the street to - - indicate. the. correct` address of the:?build`ing... ,(CF.0 505.:1) g Repair all. ( cracks /hole's /openings):,i,n pfaste_r. in (location). ------------------------ —7 ----------- -- FIRE DOORS /. Plastering, sha•II "return the surface to its original fire resistive condition. (CFC 703A.) FIRE SEPARATIONS 10 Remove /repair , (item & location). ---- -=-------- - - - - -- = - ------------ ----- - - - - -- --- - - - - -- Self= closing doors' shall . be designed to close Eby gravity;• or, by the action Of a mechanical `'device,'or by an approved smoke and. heat Sensitive'. device,.. Self - closing doors shall. have no attachments capable of preventing the operation ofahe closing.,device. (CFC 703.2) 11 Remove all obstruction from hallways... Maintain all means of egress free of any storage. (CFC 10.28.3) EXITS iz Provi.de'a colored and permanently instal.led,el6i tric light over or near required exit ,contras'ting (location) _ _ ___ ___ _ ______ ______ o clearly ,indi,cate it .as: an exit.: (CFC 1006.3) storage and /or other.obstructions.from fire escape landings; and stairways .stair shafts. (Fire STORAGE 13 Aemove.;all escapes /stair shafts are to. be mainta'ined free from o`bstructions.at all times,) (CFC 1003.6) ,. 14 , . Extension cords shall not be. used in lieu of permanent-approved wiring: Install additio.na.l approved ELECTRICAL APPLIANCES' electrical Outlets Where needed. ,. (CFC 605..5) 15 Remove multiple attachment cords from specific :ejectricaI convenience outlet ( one plug per outlet) (CFC 605.4) OUTDOOR BURNING 16 ` ' Recreational fires or open burning..! CFC 307:.1 FIREWORKS X12", Violations. of Section (CFC 5608.1):& 8.44.0,40 (B.M -C -). OTHER 18 > f`�'°` '" � � 1 S`' ° f `"`'�• .fi St...� : � �' �J a'' 1 i t ...w. � ,,' �;1 -� =:-+ f` '`+ �, CORRECTION DATE Correct the, violations noted above by: ,r -CUSTOMER: / jr/` :, +, rr. s . 1 (, c f` LEGEND: ` C.F.C. CALIFORNIA FIRE CODE. C.B.C.CALIFORNIA.BUILDING CODE B.M.C. BAKERSFIELD MUNICIPAL CODE . N.F.P.A. 'N'ATIONAL FIRE PROTECTION. ` ' (Signature) : (Please Priht.Name Legibly,.Title ' i ASSOCIATION N.E -C. NATIONALELECTRIC CODE INSPECTOR:' NO