Loading...
HomeMy WebLinkAboutMinor Mod Folder 4-26-16HOODS ALARMS SPRINKLER SYSTEMS SPRAY BOOTH AST UST Permit No. Permit No. Permit No. Permit No. Permit No. Permit No. l 2- File Number: _ 6 Date Received: V- _4z %% Address: - 5700 Bakersfield, CA 933 Business Name: ;� // > '�` °�' f Q Z0 Z2Z SYSTEM: BUILDING SQUARE FEET: New Mod. ❑ ❑ Commercial Hood System ❑ ❑ Fire Alarm System ❑ ❑ Fire Sprinkler System ❑ ❑ Spray Finish System ❑ ❑ Aboveground Storage Tank ❑ ❑ Underground Storage Tank mi;;) modifi Underground Storage Tank removal Underground Storage Tank ❑ ❑ Other: Comments: Building Sq. Feet: Calculation Bldg. Sq. Ft: INSPECTION LOG-] Date 1. L9 S T 2. 3. 4. Signature Signature BILLING PERMIT STATEMENT BAKERSFIELD FIRE DEPARTMENT s R s F I"' D Prevention Services PERMIT # FIRE 2101 H Street Bakersfield, CA 93301 - LOCATION OF PROJECT PROPERTY OWNER 5100 Gasoline Alley Drive Bill Wright Toyota STARTING DATE COMPLETION DATE NAME 04/05/2016 4/5/16 PROJECT NAME ADDRESS Bill Wright Toyota 5100 Gasoline Alley Drive PHONE # (661) 398 -8697 PROJECT ADDRESS Clfl 5100 Gasoline Alley Drive C g�C �� 5� (� L� STATE A ZIP CODE 93313 CONTRACTOR INFORMATION CONTRACTOR NAME CA LICENSE # TYPE Frank Landa 804904 OF LICENSE EXPIRATION DATE A, C61 -D40, Haz 03/31/2016 PHONE # (661) 631 -3870 CONTRACTOR COMPANY NAME Confidence UST Services, Inc. FAX # (661) 587 -9758 ADDRESS 16250 Meacham Road CITY Bakersfield ZIP CODE 93314 II permits must be reviewed, stamped, and approved PRIOR TO BEGINNING - New & Modification (minimum charge) $280 • 71 0Alarm ❑ Over 10,000 sq ft $0 .028 x sq ft ❑ Sprinkler - New & Modification (minimum charge) $280 ❑ Over 10,000 sq ft $0 .028 x sq ft ❑ Sprinkler - Minor Modification ( <10 heads) $ 96 (inspection only) 84 ❑ Commercial Hood (New & UL 300 Upgrade Modification) Additional Hood $470 58 hood ❑ Commercial Hood - Minor Modification (add /move nozzle) $ 96 (inspection only) 84 ❑ Spray Booth (New & Modification) $470 98 ❑ Aboveground Storage Tank (1 inspection per installation) AST $180 /tank 82 ❑ Additional Tank ATI $ 96 /tank 82 ❑ Aboveground Storage Tank (Removal, Mod,or Inspect'n) ATR $109 /tank 82 ❑ Underground Storage Tank (Installation /Inspection) NI $878 /tank 82 ❑ Underground Storage Tank (Modification) MOD $878 /site 82 (� Underground Storage Tank (Minor Modification) MTM $167 /site 82 ❑ Underground Storage Tank (Removal) TR $573 /tank 84 ❑ Mandated UST Testing: Fuel Mont Cert /SB989 /Cath. Prot. NOTE: $96 /hr for each type of test /per site /per UST system even if scheduled at the same time $ 96 /hr (2 hrs minimum) _ $192 82 ❑ Oil well (Installation, Inspection, or re- inspection) X $ 96 /hr 82 ❑ Tent # $ 96 /tent 84 ❑ After -hours inspection fee $121 /hr (2 hrs minimum) = $242 ❑ Pyrotechnic (1 permit per event, plus an inspection fee of $96 /hr during business hours) PY NOTE: After hours Pyrotechnic event inspection is @ $121/hr $ 96 /hr + (5 hrs min standby fee /insp) _ $576 5 hrs in standby fee /ins = $605 84 • Re- inspection /Follow -up Inspection $ 96 /hr 84 • Portable LPG (Propane): # of Cages? $ 96 /hr 84 • Explosive Storage $266 84 ❑ Copying & File Research (File Research fee $50 /hr) $0.25 /page 84 ❑ Miscellaneous 84 UNDERGROUND STORAGE TANK PERMIT APPLICATION TO CONSTRUCT - INSTALL NEW TANK (NEW FACILITY) /NEW TANK INSTALL (EXISTING FACILITY) /MOD -MINOR MOD Permit # /��_� TYPE OF /APPLICATION: ❑ NEW TANK INSTALL /NEW FACILITY �i_r_r^v �nC rnii v\ I—I MnnTCTr`A -rT!" m r1C GA(—T1 TTV ❑ NEW TANK INSTALL /EXISTING FACILITY F.771 MTNr1R MC)nTFTr'ATTnN OF FACTI TTY STARTING DATE/ 04/05/2016 F4/5/16 POSED COMPLETION DATE FACILITY NAME Bill Wright Toyota EXISTING FACILITY PERMIT # FACILITY ADDRESS 5100 Gasoline Alley Drive CITY Bakersfield ZIP CODE 193313 TYPE OF BUSINESS Auto Dealership APN # TANK OWNER Bill Wright Toyota PHONE # (661) 398 -8697 ADDRESS 5100 Gasoline Alley Drive CITY Bakersfield ZIP CODE 93313 CONTRACTOR Confidence UST Services Inc. CA LICENSE # 1 804904 ICC # - 8180171 -U1 ADDRESS 16250 Meacham Road CITY Bakersfield ZIP CODE 93314 PHONE # 661- 631 -3870 1 BAKERSFIELD CITY BUSINESS LICENSE # 32864 WORKMANS COMP # 1 1308371 INSURER SCIF BRIEFLY DESCRIBE THE WORK TO BE DONE: Install Bravo Conv -82000 Series Conversation Frame (see attached photo in blue box) WATER TO FACILITY PROVIDED BY DEPTH TO GROUND WATER SOIL TYPE EXPECTED AT SITE # OF TANKS TO BE INSTALLED ARE THEY FOR MOTOR FUEL? SPILL YES NO PREVENTION CONTROL AND COUNTERMEASURES PLAN ON FILE? YES NO THIS SECTION IS FOR STORAGE TANK IDENTIFICATION TANK # VOLUME UNLEADED REGULAR PREMIUM_ DIESEL OTHER 1 10000 X X Tank Testing Company NAME OF TESTING COMPANY Confidence UST Services Inc. PHONE NUMBER 661 -631 -3870 MAILING ADDRESS 16250 Meacham Road, Bakersfield, CA 93314 NAME OF TESTER ICC# THE APPLICANT HAS RECEIVED, UNDERSTANDS, AND WILL COMPLY WITH THE ATTACHED CONDITIONS OF THIS PERMIT AND ANY OTHER STATE, LOCAL, AND FEDERAL REGULATIONS. THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY, AND TO THE BEST OF MY KNOWLEDGE IS TRUE AND CORRECT. NAME OF TESTER Frank Landa ICC# 8180171 -U1 THIS APPLICATION BECOMES A PERMIT WHEN APPROVED FOR OFFICIAL USE ONLY DATE APPROVED -' 4-1125-116 APPROVED BY �f_"z4<x\�9 Fn -5 nAr, (Rav nRinA) CONVmB2000 SERIES DISPENSER CONVERSION FRAMES ® on ■ . WI N a .��t;e�, sa List 495 658 GA- CONVB2K O tlon that adds Galvanized coat and E owder coat $ 140 Dispenser Brand and Model Number are Required for Every Order. Use Order Form. Below, Part Number Description MO -400 1-1/2" Offset, 1 -1/2" NPT Male x 1 -1/2" NPT Female MO -401 List 1" Offset, 1 -1/2" NPT Male x 1 -1 /2" NPT Female MO -402 $ 46 11 2" Offset, 1 -1/2" NPT Male x 1 -1/2" NPT Female MO -403 46 3" Offset, 1 -1/2" NPT Male x 1 -1/2" NPT Female 46 51 * NOTE: Offset Information provided in Bravo Systems Blueprints are deemed accurate but must be verified to be compatible with Existing and New Dispense b rs y the Insta lling Contra ctor It is the responsibility of the End User to verify that the correct Offsets are being ordered. oft,