Loading...
HomeMy WebLinkAboutFire Safety Insp 9-28-16BAKERSFI.ELD .FIRE DEPARTMENT FIRE PREVENTION .INSPECTION Preventoln Selrvices` 2101 H Street • �~� x� a aRTN r Bakersfield, CA .93301 .F Phone:' 661= 326 -3979 • Fax: 6,61- 852 -2171 DISTRICT BLOCK.NO. DATE f FEE f FACILITY ADDRESS w� v mss " � ;,: — 7 e_f . ; t% n , STATE, - CI. TY TA P T r FACILITY NAM�E -` k s ;t- MANAGER'S NAME O r PH / N S BUSINESS OWNER'S NAME AND ADDRESS `- CITY, ;STATE, ZIP, PH NO. BILL TO:. (IF DIFFERENT FROM. ABOVE) NAME, ADDRESS CITY, STATE, ZIP, PH NO. OCC TYPE OCC LOAD NO. OF FLOORS HIGH RISE BLDG RISER DATE .� ❑ YES NO, CORRECT ALL VIOLATIONS. VIOLATION REQUIREMENTS CHECKED BELOW NO. 1. Remove and safely dispose of all hazardous r.ef.use and dry vegetation on: the above premises (;CFC ' COMBUSTIBLE WASTE / DRY 304. 1'. 1), VEGETATION . 2 Provide non'- co_mb.ustible containers with tight fitting lids for the storage of combustible waste and, rubbish pending. its safe' disposal. (CFC 304..3.2) N..ote:_ applies to containers over 40- ga.11ons.. _ COMBUSTIBLE STORAGE 3 ` Relocate com- bustible storage`to provide at least-3 feet :clearance around motor . fuse box /fire door *(CFC .605.3) 4 Relocate fire extinguishers) so that they. wil.1 be in a :conspicuous location, hanging on brackets with the to.p to, the extinguisher not more than 5 feet above the floor. .(CFC 906.5. &.906..9) EXTINGUISHERS 5 Provide and install. - {amount) approve d (type. &.size) _ -------------- _ portable.. fire ____ __ -__ -_ —_ extinguisher to be'. imrrredia ely accessible for use .in (area) (CFC TABLE 906.3.(1)) 6 _ Re- charge all fire extinguishers. Fire extinguishers shall be .serviced at least on.ce.each year, and /or after each use, by.a person . having a valid IjCense.o:r c•ertific6te.., .(CFC 9:06.2) :- 7 Provide and maintain "EXIT" 'sign(s) with. .letters: 6 or -more inches in height over each required exit SIGNS (door /window) to`fire escape. (CFC 1011) - g Provide and maintain appropriate .numbers on a contrasting back.gro.und and visible from the street to' indicate the correct address of the' building. (CFC 505.1). . 9 Repair all ( cracks /holes /openings) in plaster 'in (Loca.tion) _ — �_ --- _----------------- __ _ _ _____ FIRE DOORS/ Plastering.,shall return the surface to. its original flare resistive .condition. (.CFC 703.1) .FIRE SEPARATIONS 10 R e m o v e j r e p a i r (item & I o c a t i o n.) - - -- ------- =---=- - - - - -- - -- ------- - - - - -- ---------------- Selc osing doors shall 'be designed to close by gravity, or by the action of a mechanical device, or by an approved smoke and heat' sensitive device. • Self - closing. doors.• shall have no a'ttachmentscapab.l.e of preventing the operation of the closing device. (CFC 70.3:2) 11 Remove all* obstruction from hallways. Mai.ntain "all means of egress free of any storage. (CFC 102.8:3). EXITS 12 Provide a contrasting colored and permanently installed electric light over or near required exit (location) _ _ __ -_ _ __ _____ -_..to clearly indicate it as an.exit. _ (,CFC' 1006.3) 13 all storage and /or other obstructions, from fire escape landings anal stairways stair shafts., (.Fire STORAGE - .Remove escapes /stair shafts, are to be maintained free from obstructions. at a.II times:.) :(CFC 1003.6) 14 .. Extension cords sKa.11 not be used in lieu. of permanent approved wiring. Install additional approved ELECTRICAL APPLIANCES electrical outlets where needed. .(CFC 605.5) 15 Remove .multiple attachment cords from specific electrical.. convenience outlet (one plug per outlet) (CFC 605.4) OUTDOOR BURNING 16 Recreational fires or open burning'. CFC 307.1 FIREWORKS :17 Violations of Section (CFC 5608:1)•& 8.44.040 (B,M.C.). OTHER _. tA, vc "r s' Oaf 77 f CORRECTION DATE - t • Correct the violation s.' noted. above by: i LEGEND: 1 " C.F:C. CALIFORNIA FIRE'CODE C B.C. CALIFORNIA BUILDING, CODE CUSTOMER: .► BAKERS MUNICIPAL CODE (Signature) ` (PleaA Print Name Legibly, Title B .FIELD N.F.P ;A. NATIONAL FIRE. PROTECTION. ASSOCIATION 1 ' IN SPECTOR: �? ' S =- ,'. -�`. A ° "�"" N�.: N.E.C. NATIONAL ELECTRIC CODE