HomeMy WebLinkAboutORD NO 4878ORDINANCE NO. 4878 AN ORDINANCE AMENDING CHAPTER 15.04 OF THE BAKERSFIELD MUNICIPAL CODE RELATING TO BUILDING AND CONSTRUCTION AND ADOPTING THE 2016 CALIFORNIA BUILDING CODE, 2016 CALIFORNIA MECHANICAL CODE, 2016 CALIFORNIA PLUMBING CODE, 2016 CALIFORNIA ELECTRICAL CODE, 2016 CALIFORNIA EXISTING BUILDING CODE, 2016 CALIFORNIA HISTORICAL BUILDING CODE, 2016 CALIFORNIA RESIDENTIAL CODE AND 2013 CALIFORNIA GREEN BUILDING CODE BY AMENDING CHAPTERS 15.04, 15.05, 15.07, 15.09, 15.11, 15.13, 15.15, 15.17 AND 15.19 THERETO. WHEREAS, Health and Safety Code Section 17958 provides that the City of Bakersfield shall adopt Ordinances and regulations imposing the some or modified or changed requirements as are contained in the regulations adopted by the State pursuance to Health and Safety Code Section 17922; and WHEREAS, the State of California is mandated by Health and Safety Code Section 17922 to impose the same requirements as are contained in the most recent edition of the California Building Code, California Existing Building Code, the California Plumbing Code, the California Mechanical Code, and the California Electrical Code (hereinafter referred to collectively as "Codes "); and WHEREAS, Health and Safety Code Section 17958.7 permits the City to make modifications or changes to the Codes, which are reasonably necessary because of local climatic, geographic or topographic conditions; and WHEREAS, the Building Division staff determined that the local amendments to the Codes are necessary due to unique conditions that exist in the City of Bakersfield which include conditions conducive to steep terrain, extremely high temperatures in the summer and extremely poor visibility due to Tule fog conditions in the winter; and WHEREAS, the City of Bakersfield typically exceeds temperatures of 90° F during the summer months of June, July, August, and September and during the winter months typically experiences a high percentage of poor visibility days from zero visibility to 300 feet; and o``et,KE9� Page 1 of 46 Pages ,. m F- r U � ORIGINAL WHEREAS, the City of Bakersfield is situated in the southern San Joaquin Valley which is surrounded by the Sierra Nevada Mountains on the east, the Coastal Range on the west, and the Tehachapi Mountains on the south and is subject to periodic seismic activity from earthquake faults associated with those geologic features; and WHEREAS, the citizens of the City of Bakersfield are susceptible to high occurrence of Valley Fever due to dust conditions in the local area; and WHEREAS, the Building Division has reviewed and recommended that changes and modifications be made to the Codes and have advised that certain said changes and modifications to the California Building Code, 2016 Edition, the California Mechanical Code, 2016 Edition, the California Plumbing Code, 2016 Edition, the California Electrical Code, 2016 Edition, the California Residential Code, 2016 Edition and the California Green Building Code, 2016 Edition, are reasonably necessary due to local conditions in the City of Bakersfield as indicated above; and therefore BE IT ORDAINED by the Council of the City of Bakersfield as follows: SECTION 1. Chapter 15 of the Bakersfield Municipal Code is hereby amended to read as follows: Chapter 15 BUILDINGS AND CONSTRUCTION CODE I. BUILDINGS AND CONSTRUCTION CODE Chapter 15.04 BUILDINGS AND CONSTRUCTION Chapter 15.05 CALIFORNIA BUILDING CODE Chapter 15.07 CALIFORNIA MECHANICAL CODE Chapter 15.09 CALIFORNIA PLUMBING CODE Chapter 15.11 CALIFORNIA ELECTRICAL CODE Chapter 15.13 CALIFORNIA EXISTING CODE Chapter 15.15 CALIFORNIA HISTORICAL BUILDING CODE Chapter 15.17 CALIFORNIA RESIDENTIAL CODE Chapter 15.19 CALIFORNIA GREEN BUILDING CODE Chapter 15.20 UNIFORM HOUSING CODE Chapter 15.24 UNIFORM CODE FOR THE ABATEMENT OF DANGEROUS BUILDINGS Chapter 15.36 UNIFORM SIGN CODE Chapter 15.38 WATER METERS Chapter 15.40 EARTHQUAKE HAZARD REDUCTION IN EXISTING UNREINFORCED MASONRY BEARING WALL BUILDINGS Chapter 15.41 SEISMIC SAFETY ADMINSITRATION OF UNREINFORCED MASONRY BUILDINGS Page 2 of 46 Pages n �+ 'ORIGINAQ Chapter 15.42 DEWELLING UNIT LOCATION IDENTIFICATION IN MULTIPLE DWELLING UNITY COMPLEXES Chapter 15.44 MOVED BUILDINGS Chapter 15.50 PAY TOILETS Chapter 15.52 HOUSE NUMBERS Chapter 15.54 HANDICAPPED ACCESS APPEALS BOARD SECTION 2. Chapter 15.04 of the Bakersfield Municipal Code is hereby amended to read as follows: Chapter 15.04 BUILDINGS AND CONSTRUCTION CODE 15.04.010 Findings designated. The City Council does expressly find and determine that the changes and modifications to the 2016 Editions of the California Codes, as adopted by the ordinance codified in this title pursuant to Sections 17922, 17958 and 17958.5 of the Health and Safety Code, contained in this title are reasonably necessary because of local conditions. SECTION 3. Chapter 15.05 is hereby amended to the Bakersfield Municipal Code as follows: Chapter 15.05 CALIFORNIA BUILDING CODE 15.05.010 Adoption 15.05.020 Deletions. 15.05.030 Modifications. 15.05.040 Chapter I Division II Section 104 — Duties and Powers of Building Official. 15.05.050 Chapter 1 Division 11 Section 109 —Fees. 15.05.060 Section 903.2 amended - Automatic Sprinkler System; where required. 15.05.070 Section 1612.A.6 added -- Geological or flood hazards 15.05.080 Section 1705 — Concrete Construction Required Verification and Inspection. 15.05.090 Section 1704.6 Structural Observations. 15.05.100 Section 1807 Foundation Walls, Retaining Walls and Embedded Posts and Poles 15.05.110 Section 1809 Shallow Foundations 15.05.120 Section 1810 Deep Foundations 15.05.130 Section 1905 Modifications to ACI 318 15.05.140 Reserved 15.05.150 Reserved 15.05.160 Section 2304 General Construction Requirements 15.05.170 Appendix J Grading. oF9ANf9'r.., Page 3 of 46 Pages m U � ORIGINAL 15.05.010 Adoption. Except as provided in this chapter, that certain building code known and designated as the California Building Code, 2016 Edition including Chapter 1 Division II, Appendix I, and J, which code was based on the 2015 International Building Code as published by the International Code Council and, a copy of which is on file in the building department of the city for use and examination by the public, and each portion and provision thereof, is adopted by reference as modified and amended in this chapter and is declared to be the building code of the city for the purpose of regulating the erection, construction, enlargement, alteration, repair, moving, removal, demolition, conversion, occupancy, use, height and maintenance of all structures and certain equipment therein specifically regulated within the incorporated limits of issuance of permits and the collection of fees thereof. 15.05.020 Deletions. The following sections, tables and chapters of the California Building Code, 2016 Edition, or appendix thereto, are not adopted as part of the ordinance codified in this chapter and are deleted: Section 113 - Board of Appeals Appendix A - Employee Qualification Appendix B - Board of Appeals Appendix C - Group U: Agricultural Building Appendix D - Fire District Appendix F - Rodentproofing Appendix G - Flood Resistance Construction Appendix H -Signs Appendix K - Group R -3 and Group R -3.1 Occupancies Protected by the Facilities of the Central Valley Flood Protection Plan. Appendix L - Earthquake Recording Instrumentation Appendix M - Tsunami- Generated Flood Hazard 15.05.030 Modifications. gAK,'q Page 4 of 46 Pages o F sT v o ORIGINAL The sections of the California Building Code, Volumes 1 and 2, 2016 Edition, Appendix J mentioned in Sections 15.05.040 through 15.05.170 of this chapter, as adopted by reference, are amended as provided in Sections 15.05.040 through 15.05.170 of this chapter. 15.05.040 Section 104— Duties and Powers of Building Official. Subsection 104.2.12 Added —Dust abatement. Subsection 104.12 is added to read as follows: Dust abatement shall comply with current standards as set forth by the San Joaquin Valley Air Pollution Control District. The Building Official shall have the authority to require any reasonable means, including the use of water, to prevent dust or other particles from polluting the air and to prevent or abate any nuisance caused by the performance of any of the building or work authorized by this code. Any person engaged in the doing or causing such building or work to be done shall, by the use of water or other means approved by the building official, prevent dust or other particles from polluting the air or becoming a nuisance. 15.05.050 Section 109 —Fees. Subsection 109.2 is amended to read as follows: All plan check and permit fees shall be assessed in accordance with the Master Fee Schedule adopted by the City. Subsection 109.6 is amended to read as follows: 109.6 Refunds. All requests for refunds shall be made in writing by the applicant and shall include the reason for termination of the project. Refunds will be processed as follows: Prior to any plan checking or other work being done by the Department. a. Refund of fees paid, including plan check fees, but less a processing fee and any fees required by the State of California that have not been submitted to the State (i.e. Strong Motion Instrumentation or CBSC fee). 2. After plan check by the Department has started, but prior to the start of construction. pRepKF9'I.� Page 5 of 46 Pages m U � ORIGINAL a. Refunds of fees paid, less all plan check fees and less a processing fee and any fees required by the State of California that have not been submitted to the State (i.e. Strong Motion Instrumentation or CBSC fee). b. The approved plans and job card must be returned to the Department prior to issuing the refund. No refund will be issued for a permit that has expired or where construction has commenced. 15.05.060 Section 903.2 amended - Automatic Sprinkler System; where required. Subsection 903.2 Where required. For the purpose of this code, where the condition of 'the fire area exceeds 12,000 square feet (115 m')" appears within Section 902.2 et seq. of this code, it shall be amended to read "The fire area exceeds 10,000 square feet (892 m')." 15.05.070 Section 1612.6 added — Geological or flood hazards. Section 1612.6 is added to read as follows: Section 1612.6 Geological or Flood Hazards. If in the opinion of the Building Director a structure to be used for human habitation or occupancy is proposed to be located such that it would be subject to geological or flood hazards or mud slide, to the extent that it would endanger human life or safety, a permit to construct shall be denied, unless corrective work satisfactory to the Building Director can be done to eliminate or sufficiently reduce the hazard. No structures shall be permitted where prohibited under the City flood plain Management Ordinance. The Building Director, in formulating his opinion as to the extent of the hazard, may take into consideration such data as is available from federal, state and local agencies having information and knowledge relative to such hazardous conditions. He may require applicants to furnish geological and /or engineering studies, reports and recommendations prepared by a registered geologist and /or civil engineer for corrective work, sufficient to establish the safety of the proposed structure, including a statement verifying all corrective work was performed. 15.05.080 Section 1705 — Required Verification and Inspection. Subsection 1705.3 is amended to read as follows: 1705.3 Concrete Construction. The special inspections and verifications for concrete construction shall be as required by this section and Table 1705.3. 11 oOAKFgN Page 6 of 46 Pages U O ORIGINAL Exceptions: Special inspection shall not be required for: 1. Isolated spread concrete footings of buildings three stories or less above grade plane that are fully supported on earth or rock, where the structural design of the footing is based on a specified compressive strength, fc. no greater than 2,500 pounds per square inch (psi) (17.2 Mpa). 2. Continuous concrete footings supporting walls of buildings three stories or less in height that are fully supported on earth or rock where: 2.1. The footings support walls of light -frame construction; 2.2. The footings are designed in accordance with Table 1809.7; or 2.3. The structural design of the footing is based on a specified compressive strength, fc, no greater than 2,500 pounds per square inch (psi) (17.2 Mpa), regardless of the compressive strength specified in the construction documents or used in the footing construction. 3. Nonstructural concrete slabs supported directly on the ground, including prestressed slabs on grade, where the effective prestress in the concrete is less than 150 psi (1.03 Mpa). 4. Concrete patios, driveways and sidewalks, on grade. 15.05.090 Secillon 1704.6 amended - Structural Observations. Subsection 1704.6 is amended to read as follows: 1704.6 Structural Observations. Where required by the provisions of Section 1704.6.1 or 1704.6.2, the owner shall employ a structural observer to perform structural observations as defined in Section 1702. Structural observation does not include or waive the responsibility for inspection in Section 110 or the special inspections in Section 1705 or other sections of this code. The structural observer shall be one of the following individuals: 1. The registered design professional responsible for the structural design, or 2. A registered design professional qualified to do required observation and familiar with the design of the structural. Prior to the commencement of observations, the structural observer shall submit to the building official a written statement identifying the frequency and extent of structural observations. o eAKF9lp Page 7 of 46 Pages m � o ORIGINAL The owner or owner's representative shall coordinate and call a preconstruction meeting between the structural observer, contractors, affected subcontractors and special inspectors. The structural observer shall preside over the meeting. The purpose of the meeting shall be to identify the major structural elements and connections that affect the vertical and lateral load resisting systems of the structure and to review scheduling of the required observations. A record of the meeting shall be included in the report submitted to the building official. Observed deficiencies shall be reported in writing to the owner or owner's representative, special inspector, contractor and the building official. Upon the form prescribed by the building official, the structural observer shall submit to the building official a written statement at each significant construction stage stating that the site visits have been made and identifying any reported deficiencies which, to the best of the structural observer's knowledge, have not been resolved. A final report by the structural observer which states that all observed deficiencies have been resolved is required before acceptance of the work by the building official. 15.05.100 Section 1807 amended - Foundation Walls, Retaining Walls and Embeded Posts and Poles. Subsection 1807.1.4 is amended to read as follows: 1807.1.4 Permanent wood foundation systems. Permanent wood foundation systems shall be designed and installed in accordance with AWC PWF. Lumber and plywood shall be treated in accordance with AWPA U1 (Commodity Specification A, Use Category 4B and Section 5.2) and shall be identified in accordance with Section 2303.1.9.1. Permanent wood foundation systems shall not be used for structures assigned to Seismic Design Category D, E or F. Subsection 1807.1.6 is amended to read as follows: 1807.1.6 Prescriptive design of concrete and masonry foundation walls. Concrete and masonry foundation walls that are laterally supported at the top and bottom shall be permitted to be designed and constructed in accordance with this section. Prescriptive design of foundation walls shall not be used for structures assigned to Seismic Design Category D. E or F. Footnotes for Table 1809.7 Prescriptive Footings Supporting Walls of Light - Frame Constructions is amended to read as follows: For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm (a). Depth of footings shall be in accordance with Section 1809.4. Page 8 of 46 Pages (b). The ground under the floor shall be permitted to be excavated to the elevation of the top of the footing. (c). See Section 1905 for additional requirements for concrete footings of structures assigned to Seismic Design Category C. D, E or F. (d). For thickness of foundation walls, see Section 1807.1.6. (e(. Footings shall be permitted to support a roof in addition to the stipulated number of floors. Footings supporting roof only shall be as required for supporting one floor. 15.05.110 Section 1809 amended - Shallow Foundations. Subsection 1809.12 is amended to read as follows: 1809.12 Timber footings. Timber footings shall be permitted for buildings of Type V construction and as otherwise approved by the building official. Such footings shall be treated in accordance with AWPA U1 (Commodity Specification A, Use Category 4B(. Treated timbers are not required where placed entirely below permanent water level. or where used as capping for wood piles that project above the water level over submerged or marsh lands. The compressive stresses perpendicular to grain in untreated timber footing supported upon treated piles shall not exceed 70 percent of the allowable stresses for the species and grade of timber as specified in the AF &PA NDS. Timber footings shall not be used in structures assigned to Seismic Design Category D. E or F. 15.05.120 Section 1810 amended - Deep Foundations. Subsection 1810.3.2.4 is amended to read as follows: 1810.3.2.4 Timber. Timber deep foundation elements shall be designed as piles or poles in accordance with AF &PA NDS. Round timber elements shall conform to ASTM D 25. Sawn timber elements shall conform to DOC PS -20. Timber shall not be used in structures assigned to Seismic Design Category D. E or F. 15.05.130 Section 1905 amended - Modifications to ACI 318. Subsection 1905.1.7 is amended to read as follows: 1905.1.7 ACI 318, Section 14.1.4. Delete ACI 318, Section 14.1.4, and replace with the following: o�`0ANF9s Page 9 of 46 Pages m U O ORIGINAL 14.1.4— Plain concrete in structures assigned to Seismic Design Category C, D. E or F. 14.1.4.1 — Structures assigned to Seismic Design Category C, D, E or F shall not have elements of structural plain concrete, except as follows: (a) Concrete used for fill with a minimum cement content of two (2) sacks of Portland cement per cubic yard. (b) Isolated footings of plain concrete supporting pedestals or columns are permitted, provided the projection of the footing beyond the face of the supported member does not exceed the footing thickness. (c) Plain concrete footings supporting walls are permitted provided the footings have at least two continuous longitudinal reinforcing bars. Bars shall not be smaller than No. 4 and shall have a total area of not less than 0.002 times the gross cross - sectional area of the footing. A minimum of one bar shall be provided at the top and bottom of the footing. Continuity of reinforcement shall be provided at corners and intersections. All concrete floor slabs poured on earth, for buildings of group R occupancies, including garage floor slabs, shall be reinforced with a welded wire fabric of 6 x 6 -10/10 minimum weight or approved equal. Exceptions: In detached one- and two- family dwellings three stories or less in height and constructed with stud - bearing walls, plain concrete footings with at least two continuous longitudinal reinforcing bars not smaller than No. 4 are permitted to have a total area of less than 0.002 times the cross cross - sectional area of the footing. 15.05.160 Section 2304 amended - General Construction Requirements. Subsection 2304.12.5 is amended to read as follows: 2304.12.5 Wood used in retaining walls and cribs. Wood installed in retaining or crib walls shall be preservative treated in accordance with AWPA U1 (Commodity Specifications A or F) for soil and fresh water use. Wood shall not be used in retaining or crib walls for structures assigned to Seismic Design Category D, E or F. Subsection 2308.6.8.1 is amended to read as follows: 2308.6.8.1 Braced wall line support. Braced wall lines shall be supported by continuous foundations. �gAKF9 Page 10 of 46 Pages ° mT m U p ORIGINAL Exception: For structures with a maximum plan dimension not over 50 feet )15240 mm), continuous foundations are required at exterior walls only for structures not assigned to Seismic Design Category D, E or F. 15.05. 170 Appendix J Grading. Section J101 of Appendix Chapter J of Title 24 of the California Building Code is amended to read as follows: SECTION .1101.1— Scope. This appendix sets forth rules and regulations to control excavation and grading including fills or embankments, and the control of grading site runoff, including erosion sediments and construction - related pollutants. These regulations establish minimum standards and are not intended to prevent the use of alternate materials, methods or means of conforming to such standards, provided such alternate has been approved. The Building Official shall approve such an alternate provided he or she finds that the alternate is, for the purpose intended, at least the equivalent of that prescribed in this Code in quality, strength, effectiveness, durability and safety. The Building Official shall require that sufficient evidence or proof be submitted to substantiate any claims regarding the alternate. J101.2 flood hazard areas. The provisions of this chapter shall not apply to grading, excavation and earthwork construction, including fills and embankments, in the floodways within flood hazard areas established in Section 1612.3 or in flood hazard areas where design flood elevations are specified but floodways have not been designated, unless it has been demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the proposed work will not result in any increase in the level of the base flood. J101.3 General. Whenever the Building Official determines that any existing excavation or embankment or fill on private property has become a hazard to life and limb, or endangers property, or adversely affects the safety, use or stability of a public way or drainage channel, the owner of the property upon which the excavation or fill is located, or other person or agent in control of said property, upon receipt of notice in writing from the Building Official, shall within the period specified therein repair or eliminate such excavation or embankment to eliminate the hazard and to be in conformance with the requirements of this Code. J101.4 Safety Precautions. If at any stage of the work the Building Official determines that previously approved grading is likely to endanger any public or private property or result in the deposition of debris on any public way or interfere with any existing drainage course, the Building Official may order the 0pKF9 Page 11 of 46 Pages o`` sT > m f- U � ORIGINAL work stopped by notice in writing served on any persons engaged in doing or causing such work to be done, and any such person shall forthwith stop such work. The Building Official may authorize the work to proceed if the Building Official finds adequate safety precautions can be taken or corrective measures incorporated in the work to avoid the likelihood of such danger, deposition or interference. If the grading work as done has created or resulted in a hazardous condition, the Building Official shall give written notice requiring correction. J101.5 Protection of Utilities. The permittee shall be responsible for the prevention of damage to any public utilities or services. J101.6 Protection of Adjacent Property. The permittee is responsible for the prevention of damage to adjacent property and no person shall excavate on land sufficiently close to the property line to endanger any adjoining public street, sidewalk, alley, or other public or private property without supporting and protecting such property from settling, cracking or other damage which might result. Special precautions approved by the Building Official shall be made to prevent imported or exported materials from being deposited on the adjacent public way and /or drainage courses. J101.7 Storm Water Control Measures. The permittee shall put into effect and maintain all precautionary measures necessary to protect adjacent water courses and public or private property from damage by erosion, flooding, and deposition of mud, debris, and construction- related pollutants originating from the site during grading and related construction activities. J101.8 Maintenance of Protective Devices and Rodent Control. The owner of any property on which grading has been performed pursuant to a permit issued under the provisions of this Code, or any other person or agent in control of such property, shall maintain in good condition and repair all drainage structures and other protective devices and burrowing rodent control, when they are shown on the grading plans filed with the application for grading permit and approved as a condition precedent to the issuance of such permit. Section .1102 Appendix Chapter J of Title 24 of the California Building Code is amended to include: BEDROCK is the solid, undisturbed rock in place either at the ground surface or beneath superficial deposits of alluvium, colluviums and /or soil. BEST MANAGEMENT PRACTICE (BMP) is a storm water pollution mitigation measure which is required to be employed in order to comply with the requirements of the NPDES permit issued to the City of Bakersfield/ Kern County. DESILTING BASINS are physical structures, constructed for the removal of sediments from surface water runoff. FgpKF9 s Page 12 of 46 Pages ° m v 0 ORIGINAL ENGINEERING GEOLOGIST shall mean a person holding a valid certificate of registration as a geologist in the specialty of engineering geology issued by the State of California under the applicable provisions of the Geologist and Geophysicist Act of the Business and Professions Code. GEOTECHNICAL HAZARD is an adverse condition due to landslide, settlement, and /or slippage. These hazards include loose debris, slope wash, and the potential for mud flows from natural or graded slopes. LANDSCAPE ARCHITECT shall mean a person who holds a certificate to practice landscape architecture in the State of California under the applicable landscape architecture provisions of the Business and Professions Code. LINE shall refer to horizontal location of the ground surface. NATURAL GRADE is the vertical location of the ground surface prior to any excavation or fill. PRIVATE SEWAGE DISPOSAL SYSTEM is a septic tank with effluent discharging into a subsurface disposal field, into one or more seepage pits or into a combination of subsurface disposal field and seepage pit or of such other facilities. STORM DRAIN SYSTEM is a conveyance or system of conveyances, including roads with drainage systems, municipal streets, catch basins, curbs, gutters, ditches and man -made channels, designed or used for collecting or conveying storm water. STORM WATER POLLUTION PREVENTION PLAN is a site drawing with details, notes, and related documents that identify the measures taken by the permit tee to (1) control erosion and prevent sediment and construction - related pollutants from being carried offsite by storm water, and (2) prevent nonstormwater discharges from entering the storm drain system. SURFACE DRAINAGE shall refer to flows over the ground surface. SOIL TESTING AGENCY is an agency regularly engaged in the testing of soils and rock under the direction of a civil engineer experienced in soil testing. Appendix A 03.2 Exemptions is amended to read as follows: J103.2 Exemptions. A grading permit shall not be required for the following: 1. Excavation for construction of a structure permitted under this code. 0AKF Page 13 of 46 Pages U O ORIGINAL. 2. Cemetery graves. 3. Refuse disposal sites controlled by other regulations. 4. Excavation for wells, or trenches for utilities. 5. Mining, quarrying, excavating, processing or stockpiling rock, sand, gravel, aggregate or clay controlled by other regulations, provided such operations do not affect the lateral support of, or significantly increase stresses in, soil on adjoining properties. 6. Exploratory excavations performed under the direction of a registered design professional. This shall not exempt grading of access roads or pads created for exploratory excavations. Exemption from the permit requirements of this appendix shall not be deemed to grand authorization for any work to be done in any manner in violation of the provisions of this code any other laws or ordinances of this jurisdiction. Subsections J103.3- J103.8 of Appendix J of Title 24 of the California Building Code are added to read as follows: J103.3 Conditions of Approval. In granting any permit under this Code, the Building Official may include such conditions as may be reasonably necessary to prevent creation of a nuisance or hazard to public or private property. Such conditions may include, but shall not be limited to: 1. Improvement of any existing grading to bring it up to the standards of this Code. 2. Requirements for fencing of excavations or fills which would otherwise be hazardous. J103.4 Land Use. The Building Official shall not issue a grading permit for work on a site unless the proposed land use for the site shown on the grading plan application complies with the provisions of Title 17, entitled "Zoning," of the Bakersfield Municipal Code. J103.5 Plan Review Fees. When a plan or other data are required to be submitted, a plan review fee shall be paid at the time of submitting plans and specifications for review. Said plan review fee shall be as set forth in Appendix 1, Section 108 of this Code. Separate plan review fees shall apply to retaining walls or major drainage structures as required elsewhere in this Code. o`�0PK�9'rr Page 14 of 46 Pages = "' U O ORIGINAL J103.6 Grading Permit Fees. A fee for each grading permit shall be paid to the Building Official as set forth in Appendix 1, Section 108 of this Code. Separate permits and fees shall apply to retaining walls or major drainage structures as required elsewhere in this Code. There shall be no separate charge for standard terrace drains and similar facilities. J103.7 Site Review. When the Building Official finds that a visual inspection of the site is necessary to establish drainage requirements for the protection of property, existing buildings or the proposed construction, a site inspection shall be made during plan check of grading plans. The fee for such inspection shall be as set forth in Appendix 1, Section 108 of this Code. J103.8 Un- permitted Grading. A person shall not own, use, occupy or maintain any site containing unpermitted grading. For the purposes of this Code, unpermitted grading shall be defined as any grading that was performed, at any point in time, without the required permits) having first been obtained from the Building Official. Appendix Section J104.1 is amended by adding second paragraph to read as follows: Application, plans and Specifications. The application for approval shall be in the form of a preliminary report indicating grading work to be done. When required by the Building Official, each application for approval shall be accompanied by four (4) sets of plans and specifications and supporting data consisting of a soil engineering report and engineering geology report. The plans and specifications shall be prepared and signed by a civil engineer. J104.2 Site plan requirements. In addition to the provisions of Appendix 1, Section 106 of this code, a grading plan shall show the existing grade, and finished grade in contour intervals of sufficient clarity to indicate the nature and extent of the work and show in detail it complies with the requirements of this code. The plans shall show the existing grade on adjoining properties in sufficient detail (min 20') to identify how grade changes will conform to the requirements of this code. Appendix Section J104.2 is amended by adding second and third paragraph to read as follows: Each drainage and grading plan submitted to city for approval shall conform to adopted city standards approved by the city engineer and to those contained in Chapter 16 for subdivisions. Channelized storm waters shall be continuously maintained within approved concrete gutter until terminated at an approved drainage facility, 0 `,56KF,s Page 15 of 46 Pages = m U O ORIGINAL The Building Official may, after acceptance and approval of a civil engineers report, waive or modify any requirement of this Chapter if he determines the modification or waiver will provide for the public safety and will not violate good construction practices. Subsection J104.3 of Appendix Chapter J of Title 24 of the California Building Code is amended to read as follows: J104.3 Solis Report. A soils report prepared by registered design professionals shall be provided which shall identify the nature and distribution of existing soils; conclusions and recommendations for grading procedures; soil design criteria for any structures or embankments required to accomplish the proposed grading opinion on adequacy for the intended use of sites to be developed by the proposed grading as affected by soils engineering factors; and, where necessary, slope stability studies, and recommendations and conclusions regarding site geology. All reports shall be subject to review by the Building Official. Supplemental reports and data may be required as the Building Official may deem necessary. Recommendations included in the reports and approved by the Building Official shall be incorporated in the grading plan or specifications. The Building Director of the City of Bakersfield shall not approve any building permit on any lot within any new subdivision until the final grading report as required has been submitted to, and accepted by Building Director. For tract developments a Final Soils Report shall cover the entire phase of the map. Model homes may be treated individually. Exception: A soils report is not required where the building official determines That the nature of the work applied for is such that a report is not necessary. Subsection J104.5 of Appendix Chapter J of Title 24 of the California Building Code is added and reads as follows: J104.5 Engineering Geology Report. The engineering geology report required by Section J104.1 shall include an adequate description of the geology of the site, conclusions and recommendations regarding the effect of geologic conditions on the proposed development, and opinion on the adequacy for the intended use of sites to be developed by the proposed grading, as affected by geologic factors. The engineering geology report shall include a geologic map and cross sections utilizing the proposed grading plan as a base. All reports shall be subject to review by the Building Official. Supplemental reports and data may be required as the Building Official may deem necessary. Recommendations included in the reports and approved by the Building Official shall be incorporated in the grading plan or specifications. OAKF Page 16 of 46 Pages U O ORIGINAL Subsection J104.6 of Appendix J of Title 24 of the California Building Code is added to read as follows: J104.6 Grading Plan Requirements. The plans shall include the following information: 1. General vicinity map of the proposed site. 2. Property limits and accurate contours of existing ground and details of terrain and area drainage, including area within 25 feet (7920 mm) outside of proposed boundary lines. 3. Limiting dimensions, elevations or finished contours to be achieved by the grading, and proposed drainage channels and related construction. 4. Detailed plans of all surface and subsurface drainage devices, walls, cribbing, dams and other protective devices to be constructed with, or as a part of, the proposed work, together with a map showing the drainage area and the estimated runoff of the area served by any drains. 5. Location of any buildings, structures or other features on the property where the work is to be performed and the location of any buildings, structures or other features on land of adjacent owners that are within 15 feet (4752 mm) of the property or that may be affected by the proposed grading operations. 6. Recommendations included in the soils engineering report and the engineering geology report shall be incorporated in the grading plans or specifications. When approved by the building official, specific recommendations contained in the soils engineering report and the engineering geology reports, which are applicable to grading, may be included by reference. 7. The dates of the soils engineering and engineering geology reports together with the names, addresses, and phone numbers of the firms or individuals who prepared the reports. B. A statement of the quantities of material to be excavated and /or filled and the amount of such material to be imported to, or exported from the site. 9. A statement of the estimated starting and completion dates for work covered by the permit. 10. A statement signed by the owner acknowledging that a field engineer, soils engineer and engineering geologist, when appropriate, will be BAKE Page 17 of 46 Pages � m v o ORIGINAL employed to perform the services required by this Code, whenever approval of the plans and issuance of the permit are to be based on the condition that such professional persons are so employed. These acknowledgments shall be on a form furnished by the Building Official. 11. Storm water provisions are required to be shown on the plan in accordance with the requirement of Section 8.34.060 of the Bakersfield Municipal Code. A drainage plan for that portion of a lot or parcel to be utilized as a building site (building pad), including elevations of floors with respect to finish site grade and locations of proposed stoops, slabs and fences that may affect drainage. 12. Termination of consultants. The permittee shall notify the City Building Official within forty eight hours any changes to the project civil and /or soils engineer. 13. Plans shall label all property lines and easement lines, including their respective bearings and distances. 14. Plans to show all existing and abandon wells with dimension from two property lines. 15. An approved method of proper abandonment of any feature shall be clearly detailed on plans. 16. Sufficient cross sections at all adjacent adjoining property lines to show adequate approved method of construction and disposal of drainage waters. 17. Plans shall specify all storm water conduits: locations, material types, lengths, sizes, slopes, gradients, invert elevations, minimum earth cover and approved detail method of construction. 18. The plans shall contain a statement that the design engineer shall exercise sufficient supervisory control during grading and construction to insure compliance with the plans, soils report, specifications, and codes within his preview. 19. Plans shall have a cover sheet which shall contain the following information: a. Title. b. Sheet index. c. Scope of work. gAKF d. Project address, including street number and street name. o`` 9sT a Page 18 of 46 Pages o ORIGINAL e. Assessor's parcel number. f. Legal description of property. g. Basis of bearing. h. Benchmark used including specifying location, elevation and any identifying features. i. Vicinity map indicating the project location. j. Amount of gross acreage within the project boundary areas. k. City Planning Department's Site Plan Review number for the project. I. Civil engineer firm's contact information including, engineer's name, firm's name, address and phone number. m. Geotechnical firm's contact information including, engineer's name, firm's name, address and phone number. n. Reference to preliminary soils report including name of firm prepared by and date of report. o. Property owner's contact information including, owner's name, address and phone number. p. Grading contractor firm's contact information including, contactor's name, firm's name, address and phone number. q. All sheets of plans shall be reference with a North arrow and scale. All maps and details shall be to a legible recognized standard scale. r. Overall project plan to scale. Provide a key map clearly depicting all division match /phase lines and indicating all reference sheet locations. s. Legend of all abbreviations, symbols, lines, and miscellaneous terms used. t. Indicate quantities of earth to be moved in cubic yards for every: cut (excavation), fill, import and export. Plans to state the shrinkage factor, compaction factor, amount of over excavation, and analysis of method quantities derived. u. Location including off -site construction detail plans and property owner's approval of borrow site for any imported materials. v. Location including off -site construction detail plans and property owner's approval of fill site for any exported materials. w. Specify all the codes and standards used for design conformance. x. All grading notations necessary for proper construction and as required by geotechnical soils report, codes and other design standards. y. Dust control mitigation measures pursuant to Air Pollution Control District requirements. z. All mitigation measures notations, including but not limited to: approved method of debris removal, air quality impact, �gAKF9 Page 19 of 46 Pages mr m U O ORIGINAL biological resources, cultural resources, and contaminated soil removal measures. Subsections J105.3- J105.6 of Appendix J of Title 24 of the California Building Code are added to read as follows: J105.3 Site Inspections. The Building Official shall inspect the project at the following stages of work requiring approval to determine that adequate control is being exercised by the professional consultants: Initial. When the site has been cleared of vegetation and unapproved fill and it has been scarified, benched or otherwise prepared for fill. No fill shall have been placed prior to this inspection. Rough. When approximate final elevations have been established; drainage terraces, swales and other drainage devices necessary for the protection of the building site from flooding are installed; beams installed at the top of the slopes; and the statements required by Section J105.5 have been received. Final. When grading has been completed; all drainage devices necessary to drain the building pad are installed; slope planting established, irrigation systems installed; and the as- graded plans and required statements and reports have been submitted. Supplemental Inspections. In addition to the called inspections specified above, the Building Official may make such other inspections as may be deemed necessary to determine that the work is being performed in conformance with the requirements of this Code. Investigations and reports by an approved soil testing agency, soils engineer and /or engineering geologist may be required. J105.4 Non - inspected Grading. No person shall own, use, occupy or maintain any non - inspected grading. For the purposes of this Code, non - inspected grading shall be defined as any grading for which a grading permit was first obtained, pursuant to Section J103, supra, but which has progressed beyond any point requiring inspection and approval by the Building Official without such inspection and approval having been obtained. J105.5 Final Reports. Upon completion of the rough grading work and at the final completion of the work, the following reports and drawings and supplements there to are required for engineered grading or when professional inspection is performed for regular grading, as applicable. 1. An as -built grading plan prepared by the civil engineer retained to provide such services in accordance with Section J 104 showing original grou�i@PKBq Page 20 of 46 Pages �"� U p n?iron�n� surface elevations, as- graded ground surface elevations, lot drainage patterns, and the locations and elevations of surface drainage facilities and of the outlets of subsurface drains. As- constructed locations, elevations and details of subsurface drains shall be shown as reported by the soils engineer. Civil engineers shall state that to the best of their knowledge the work within their area of responsibility was done in accordance with the final approved grading plan. 2. A report prepared by the soils engineer retained to provide such services in accordance with Section J104, including locations and elevations of field density tests, summaries of field and laboratory tests, other substantiating data, and comments on any changes made during grading and their effect on the recommendations made in the approved soils engineering investigation report. Soils engineers shall submit a statement that, to the best of their knowledge, the work within their area of responsibilities is in accordance with the approved soils engineering report and applicable provisions of this chapter. 3. A report prepared by the engineering geologist retained to provide such services in accordance with Section J104, including a final description of the geology of the site and any new information disclosed during the grading and the effect of some on recommendations incorporated in the approved grading plan. Engineering geologists shall submit a statement that, to the best of their knowledge, the work within their area of responsibility is in accordance with the approved engineering geologist report and applicable provisions of this chapter. 4. The grading contactor shall submit in a form prescribed by the building official a statement of conformance to said as -built plan and the specifications. J105.6 Notification of Completion. The permittee shall notify the building official when the grading operations are ready for final inspection. Final approval shall not be given until all work, including installation of all drainage facilities and their protective devices, and all erosion - control measures have been completed in accordance with the final approved grading plan, and the required reports have been submitted. Subsection J106.1 of Appendix Chapter J of Title 24 of the California Building Code is amended to read as follows: J106.1 Maximum Slope. The slope of cut surfaces shall be no steeper than is safe for the intended use and shall be no steeper than 1 unit vertical in 2 units horizontal (50% slope) unless the permit fee furnishes a soils engineering or an engineering geology report, or both, stating that the site has been investigated oI eNK, 9q Page 21 of 46 Pages m U O ^RIGINAL and giving an opinion that a cut at a steeper slope will be stable and not create a hazard to public or private property. Subsection J 107.4 of Appendix Chapter J of Title 24 of the California Building Code is amended to read as follows: 1107.4 Fill Material. Detrimental amounts of organic material shall not be permitted in fills. Except as permitted by the Building Official, no rock or similar irreducible material with a maximum dimension greater than 12 inches (305 mm) shall be buried or placed in fills. Exception: The Building Official may permit placement of larger rock when the soils engineer properly devises a method of placement, and continuously inspects its placement and approves the fill stability. The following conditions shall also apply: 1. Prior to issuance of the grading permit, potential rock disposal areas shall be delineated on the grading plan. 2. Rock sizes greater than 12 inches (305 mm) in maximum dimension shall be 10 feet (3048 mm) or more below grade, measured vertically. 3. Rocks shall be placed so as to assure filling of all voids with well — graded soil. 4. The reports submitted by the soils engineer shall acknowledge the placement of the oversized material and whether the work was performed in accordance with the engineer's recommendations and the approved plans. 5. The location of oversized rock dispersal areas shall be shown on he as- built plan. Subsections J107.7- J107.11 of Appendix Chapter J of Title 24 California Building Code are added to read as follows: J107.7 Compaction. Fills shall be compacted throughout their full extent to a minimum relative compaction of 90 percent of maximum dry density. Fill slopes steeper than two horizontal to one vertical shall be constructed by the placement of soil a sufficient distance beyond the proposed finish slope to allow compaction equipment to operate at the outer surface limits of the final slope surface. The excess fill is to be removed prior to completion or rough grading. Other construction procedures may be utilized when it is first shown to the satisfaction of the Building Official that the angle of slope, construction method and other factors will accomplish the intent of this Section. J107.8 Slopes to Receive Fill. Where fill is to be placed above the top of an existing slope steeper than three horizontal to one vertical, the toe of the fill shallo�eAKFgs T Page 22 of 46 Pages m U O ORIGINAL be set back from the top edge of the slope a minimum distance of 6 feet ( 1829 mm) measured horizontally or such other distance as may be specifically recommended by a soil engineer or engineering geologist and approved by the Building Official. J107.9 Inspection of Fill. For engineered grading, the soils engineer shall provide sufficient inspections during the preparation of the natural ground and the placement and compaction of the fill to be satisfied that the work is being performed in accordance with the conditions of plan approval and the appropriate requirements of this Chapter. In addition to the above, the soils engineer shall be present during the entire fill placement and compaction of fills that will exceed a vertical height or depth of 30 feet (9144 mm) or result in a slope surface steeper than two horizontal to one vertical. J107.10 Testing of Fills. Sufficient tests of the fill soils shall be made to determine the density thereof and to verify compliance of the soil properties with the design requirements, including soil types and shear strengths in accordance with the standards established by the Building Official. J107.11 Temporary storage of stockpiles. No temporary stockpile of earth will be allowed except pursuant to a grading permit issued after the City Building Official has found that such storage would not constitute a hazard to life or property, or become a public nuisance or health menace. Temporary stockpiles approved by the issuance of a grading permit shall be removed from the site within a period of time not to exceed six months from the time of the issuance of the permit, unless otherwise approved by the City Building Official or unless the fill is graded and compacted under the authority granted by a subsequent or amended grading permit. Such stockpiles shall be placed so as not to interfere with any drainage ways or access routes. The stockpile location shall not create a nuisance from blowing dust, and shall be contour graded if in a highly visible area. Subsection 109.1 of Appendix Chapter J of Title 24 of the California Building Code is amended to read as follows: J109.1 General. Unless otherwise indicated on the approved grading plan, drainage facilities and terracing shall conform to the provisions of this section for cut or fill slopes steeper than 1 unit vertical in 3 units horizontal (33.3% slope). For slopes not steeper than 3 horizontal to 1 vertical, the Building Official may require drainage and terrace design to be submitted. �gAKF9 Page 23 of 46 Pages o mT �.. m � O Subsection J109.2 of Appendix Chapter J of Title 24 of the California Building Code is amended to read as follows: J109.2 Drainage Terrace. Terraces at least 6 feet (2438 mm) in width shall be established at not more than 32 -foot (7620 mm) vertical intervals on all cut or fill slopes to control surface drainage and debris except that where only one terrace is required, it shall be at midheight. For cut or fill slopes greater than 100 feet (30,480 mm) in vertical height, one terrace at approximately midheight shall be 20 feet (6096 mm) in width. Terrace widths and spacing for cut and fill slopes greater than 120 feet (36,576 mm) in height shall be designed by the civil engineer and approved by the Building Official. Suitable access shall be provided to permit proper cleaning and maintenance. Drainage terraces shall have a longitudinal grade of not less than 5 percent or more than 12 percent and a minimum depth of 1 foot (305 mm) at the flow line. There shall be no reduction in grade along the direction of flow unless the velocity of flow is such that slope debris will remain in suspension on the reduced grade. Such terraces must be paved with reinforced concrete not less than 3 inches (76 mm) in thickness, reinforced with 6 -inch (152 mm) by 6 -inch (152 mm) No. 10 by No. 10 welded wire fabric or equivalent reinforcing centered in the concrete slab. They shall have a minimum depth at the deepest point of 1 foot (305 mm) and a minimum paved width of 5 feet (1524 mm). Drainage terraces exceeding 8 feet (2438 mm) in width need only be so paved for a width of 8 feet (2438 mm) provided such pavement provides a paved channel at least 1 foot (305 mm) in depth. Down drains or drainage outlets shall be provided at approximately 300 -foot (91.44 m) intervals along the drainage terrace or at equivalent locations. Down drains and drainage outlets shall be of approved materials and of adequate capacity to convey the intercepted waters to the point of disposal as defined in section J 109.3. Subsection J109.4 of Appendix Chapter J of Title 24 of the California Building Code is amended to read as follows: J109.4 Disposal. All drainage facilities shall be designed to carry waters to the nearest practicable street, storm drain, or natural watercourse approved by the Building Official or other appropriate governmental agency as a safe place to deposit such waters. Erosion of ground in the area of discharge shall be prevented by installation of non - erosive down drains or other devices. Desilting basins, filter barriers or other methods, as approved by the Building Official, shall be utilized to remove sediments from surface waters before such waters are allowed to enter streets, storm drains or natural watercourses. If the drainage device discharges onto natural ground, riprap or similar energy dissipaters may be required. Building pads shall have a drainage gradient of 2 percent toward a public street or drainage structure approved to receive storm waters. A lesser slope �epkp9 Page 24 of 46 Pages C, sT � m U p ORIGINAL may be approved by the Building Official for sites graded in relatively flat terrain, or where special drainage provisions are made, when the Building Official finds such modification will not result in unfavorable drainage conditions. Subsections J109.5- .1109.8 of Appendix Chapter J of Title 24 of the California Building Code are added to read as follows: J109.5 Refention /Detention Basins and Storm Water Conveyance Systems. California registered Architect, Civil or Structural Engineer shall provide hydraulic calculations and the Public Works Department shall approve all on -site storm water conveyance systems and retention /detention basins and shall be constructed in accordance with City of Bakersfield Public Works Department Standards. Exceptions: 1. Shallow sumps may be constructed with the approval of the Building Official. Shallow sumps shall be designed such that the maximum depth of water does not exceed 18 inches, are in a turf area and are not to be used for storage, parking or other use that may affect the percolation ability of the sump. The grading around the shallow sump shall be designed such that any overflow waters from the sump shall be retained onsite or onto public right of way. 2. Storm water minimum on -site residential conduit size is 4 -inch interior diameter. Storm water minimum on -site non - residential conduit size is 6 -inch interior diameter. 3. Cleanouts and manholes on -site shall be spaced pursuant to 2010 California Plumbing Code section 719. Drywells are not a permitted on -site drainage system. Storm water conveyance systems shall not pass under or through structures or building foundations. Storm water conveyance systems, other than approved retention /detention basins, shall be design to drain completely with no standing water remaining in system. Appropriate recorded legal easements shall be obtained for all storm water conveyance systems that traverse onto adjacent property or direct any storm drainage waters onto adjacent property. J109.6 Home Owners Association Maintain Drainage. Where drainage is conveyed on slopes of lots that are channelized to flow across multiple property lines, a home owners association (HOA) is required to maintain the slopes and subsequent drainage facilities. Channels are required to be directly accessible gAKF from the private or public right of way. All accessible paths shall be a minimum a< 9sT Page 25 of 46 Pages v o ORIGINAL 6 foot in width. HOA documents shall be reviewed and approved by the Building Official. J109.7 Preparation of Ground. Except where recommended by the soils engineer or engineering geologist as not being necessary, sub drains shall be provided under all fills placed in natural drainage courses and in other locations where seepage is evident. Such sub drainage systems shall be of a material and design approved by the soils engineer and acceptable to the Building Official. The permit tee shall provide continuous inspection during the process of sub drain installation to conform to approved plans and engineering geologist's and soils engineer's recommendation. Such inspection shall be done by the soil testing agency. The location of the sub drains shall be shown on a plan by the soils engineer. Excavations for the sub drains shall be inspected by the engineering geologist when such sub drains are included in the recommendations of the engineering geologist. J109.8 Pavement and Aggregate Base. Asphalt or concrete pavement and aggregate base material types and depths shall be design pursuant to the site Geotechnical Report values and the minimum anticipated traffic loading, shall not be less the minimum requirements as set forth by the City of Bakersfield Public Works Department Standards, and shall be approved by the Public Works Department. On -site asphalt concrete pavement shall not be less than 2 inches over at least 3 inches of approved aggregate base. Asphalt concrete pavement shall have a minimum drainage gradient of not less than 1.0 %. On -site Portland concrete pavement shall not be less than 4 inches. Portland concrete pavement shall have a minimum drainage gradient of not less than 0.2 %. Concentrated water flow shall be continuously maintained entirely within the boundary edges of concrete gutters as determined by hydraulic analysis. On -site concrete valley gutters shall be minimum 4 feet wide. Pedestrian walkways and parking spaces designated for the disable shall be designed to prohibit any concentrate flow of water. Appropriate recorded legal easements shall be obtained for all paths of access from a public way that traverse onto adjacent properties. Van accessible disable parking and unloading area and 8 feet behind shall have a maximum slope gradient of 4.0% in any direction, including valley gutters. Subsection J110.1 of Appendix Chapter J of Title 24 of the California Building Code is amended to read as follows: 0 8AKF9N Page 26 of 46 Pages � T C U O ORIMNIA1 .1110.1 General. The faces of cut and fill slopes shall be prepared and maintained to control erosion. This control shall be permitted to consist of effective planting. This control may consist of effective planting, erosion control blankets, soil stabilizers or other means as approved by the Building Official. Exception: Erosion control measures need not be provided on cut slopes not subject to erosion due to the erosion - resistant character of the materials. Erosion control for the slopes shall be installed as soon as practicable and prior to calling for final inspection. Subsections J110.3 -J 110.6 are added to Appendix Chapter J of Title 24 of the California Building Code to read as follows: J110.3 Planting. The surface of all cut slopes more than 5 feet (1524 mm) in height and fill slopes more than 3 feet (914 mm) in height shall be protected against damage by erosion by planting with grass or ground cover plants. Slopes exceeding 15 feet (4572 mm) in vertical height shall also be planted with shrubs, spaced at not to exceed 10 feet (3048 mm) on centers; or trees, spaced at not to exceed 20 feet (6096 mm) on centers; or a combination of shrubs and trees at equivalent spacing's, in addition to the grass or ground cover plants. The plants selected and planting methods used shall be suitable for the soil and climatic conditions of the site. Plant material shall be selected which will produce a coverage of permanent planting effectively controlling erosion. Consideration shall be given to deep- rooted plant material needing limited watering, maintenance, high root to shoot ratio, wind susceptibility and fire- retardant characteristics. All plant materials must be approved by the Building Official. J110.4 Irrigation. Slopes required to be planted by Section J110.3 shall be provided with an approved system of irrigation that is designed to cover all portions of the slope. Irrigation system plans shall be submitted and approved prior to installation. A functional test of the system may be required. For slopes less than 20 feet (6096 mm) in vertical height, hose bibs to permit hand watering will be acceptable if such hose bibs are installed at conveniently accessible locations where a hose no longer than 50 feet (15,240 mm) is necessary for irrigation. The requirements for permanent irrigation systems may be modified upon specific recommendation of a landscape architect or equivalent authority that, because of the type of plants selected, the planting methods used and the soil and climatic conditions at the site and irrigation will not be necessary for the maintenance of the slope planting. o`�0RKf9T s Page 27 of 46 Pages F= U O ORIGINAL J110.5 Plans and Specifications. Planting and irrigation plans shall be submitted for slopes required to be planted and irrigated by sections A 10.3 and J 110.4 Except as waived by the Building Official for minor grading, the plans for slopes 20 feet (6096 mm) or more in vertical height shall be prepared and signed by a civil engineer or landscape architect. J110.6 Release of Security. The planting and irrigation systems required by this section shall be installed as soon as practical after rough grading. Prior to final approval of grading and before the release of the grading security, the planting shall be well established and growing on the slopes. Section J I I I is amended by adding second paragraph to Appendix Chapter J of Title 24 of the California Building Code to read as follows: ASTM D 1557, Laboratory Characteristics Compaction of Soil Using Modified Effort ASTM D 1556, Density and Unit Weight of Soils In Place by the Sand Cone Method ASTM D 2167, Density and Unit Weight of Soils In Place by the Rubber — Balloon Method ASTM D 2937, Density of Soils in Place by the Drive — Cylinder Method ASTM D 2922, Density of Soil and Soil Aggregate In Place by Nuclear Methods ASTM D 3017, Water Content of Soil and Rock in Place by Nuclear Methods Section J 112 of Appendix Chapter J of Title 24 of the California Building Code is added to read as follows: SECTION J112 - SECURITY J112.1 Security. A permit shall not be issued for grading involving more than 1,000 cubic yards (764.6 m3) unless the owner posts with the Building Official a security in one of the following forms: 1. A bond furnished by a corporate surety authorized to do business in this state. 2. A cash deposit. 3. An instrument of credit from a financial institution subject to regulation by the State or Federal government and pledging that the funds necessary to carry out the grading are on deposit and guaranteed for payment, or a letter of credit issued by such a financial institution. Where unusual conditions or special hazards exist, the Building Official may require security for grading involving less than 1,000 cubic yards (764.6 m3). Security required by this Section may include incidental off -site grading 11 P KFgs T Page 28 of 46 Pages = m u p ORIGINAL property contiguous with the site to be developed, provided written consent of the owner of such contiguous property is filed with the Building Official. The Building Official may waive the requirements for a security for: 1. Grading being done by or for a governmental agency. 2. Grading on a site, not exceeding a slope of three horizontal to one vertical, provided such grading will not affect drainage from or to adjacent properties. 3. Filling of holes or depressions provided such grading will not affect the drainage from or to adjacent properties. J112.2 Amount of Security. The amount of security shall be based on the number of cubic yards of material in excavation or fill, whichever is greater, plus the cost of all drainage or other protective devices or work necessary to eliminate geotechnical hazards. That portion of the security valuation based on the volume of material in either excavation or fill shall be computed as set forth as follows: • 100,000 cubic yards or less -50 percent of the estimated cost of grading work. • Over 100,000 cubic yards -50 percent of the cost of the first 100,000 cubic yards plus 25 percent of the estimated cost of that portion in excess of 100,000 cubic yards. When the rough grading has been completed in conformance with the requirements of this Code, the Building Official may at his or her discretion consent to a proportionate reduction of the security to an amount estimated to be adequate to ensure completion of the grading work, site development or planting remaining to be performed. The costs referred to in this section shall be as estimated by the Building Official. J112.3 Conditions. All security shall include the conditions that the principal shall: 1. Comply with all of the provisions of this Code, applicable laws, and ordinances; 2. Comply with all of the terms and conditions of the grading permit; 3. Complete all of the work authorized by the permit. J112.4 Term of Security. The term of each security shall begin upon the filing thereof with the Building Official and the security shall remain in effect until the work authorized by the grading permit is completed and approved by the Building Official. A 12.5 Default Procedures. In the event the owner or the owner's agent shall fail to complete the work or fail to comply with all terms and conditions of, OAKFq�T Page 29 of 46 Pages U p ORIGINAL the grading permit, it shall be deemed a default has occurred. The Building Official shall give notice thereof to the principal and security or financial institution on the grading permit security, or to the owner in the case of a cash deposit or assignment, and may order the work required to complete the grading in conformance with the requirements of this Code be performed. The surety or financial institution executing the security shall continue to be firmly bound under an obligation up to the full amount of the security, for the payment of all necessary costs and expenses that may be incurred by the Building Official in causing any and all such required work to be done. In the case of a cash deposit or assignment, the unused portion of such deposit or funds assigned shall be returned or reassigned to the person making said deposit or assignment. J112.6 Right of Entry. The Building Official or the authorized representative of the Surety Company or financial institution shall have access to the premises described in the permit for the purpose of inspecting the work. In the event of default in the performance of any term or condition of the permit, the surety or financial institution or the Building Official, or any person employed or engaged in the behalf of any of these parties, shall have the right to go upon the premises to perform the required work. The owner or any other person who interferes with or obstructs the ingress to or egress from any such premises, of any authorized representative of the surety or financial institution or of the City of Bakersfield engaged in the correction or completion of the work for which a grading permit has been issued, after a default has occurred in the performance of the terms or conditions thereof, is guilty of a misdemeanor. Section J113 is added to Appendix Chapter J of Title 24 of the California Building Code to read as follows: SECTION J113 — NATIONAL POLLUTION DISCHARGE ELIMINATION SYSTEM ( NPDES) COMPLIANCE J113.1 General. All grading plans and permits shall comply with the provisions of this section for NPDES compliance. J113.2 Storm Water Pollution Prevention Plan (SWPPP). No grading permit shall be issued unless the plans for such work include a Storm Water Pollution Prevention Plan with details of best management practices, including desilting basins or other temporary drainage or control measures, or both, as may be necessary to control construction- related pollutants which originate from the site as a result of construction related activities. Page 30 of 46 Pages 3 0 ORIGINAL All best management practices shall be installed before grading begins. As grading progresses, all best management practices shall be maintained in good working order to the satisfaction of the Building Official unless final grading approval has been granted by the Building Official and all permanent drainage and erosion control systems, if required, are in place. J113.3 Wet Weather Erosion Control Plans (WWECP). In addition to the SWPPP required in section J113.2 where a grading permit is issued and it appears that the grading will not be completed prior to November 1, then on or before October 1 the owner of the site on which the grading is being performed shall file or cause to be filed with the Building Official a WWECP which includes specific best management practices to minimize the transport of sediment and protect public and private property from the effects of erosion, flooding or the deposition of mud, debris or construction related pollutants. The best management practices shown on the WWECP shall be installed on or before October 15. The plans shall be revised annually or as required by the Building Official to reflect the current site conditions. The WWECP shall be accompanied by an application for plan checking services and plan- checking fees equal in amount to 10 percent of the original grading permit fee. J113.4 Storm Water Pollution Prevention Plan, Effect of Noncompliance. Should the owner fail to install the best management practices required by Sections J113.2 and J113.3 or submit the wet weather erosion control plans required by Section J113 by the dates specified therein, it shall be deemed that a default has occurred under the conditions of the grading permit security. Thereupon, the Building Official may enter the property for the purpose of installing, by City forces or by other means, the drainage, erosion control and other devices shown on the approved plans, or if there are no approved plans, as the Building Official may deem necessary to protect adjoining property from the effects of erosion, flooding, or the deposition of mud, debris or constructed related pollutants, or the Building Official may cause the owner to be prosecuted as a violator of this Code or may take both actions. The Building Official shall have the authority to collect the penalties imposed by this section upon determining that the site is non - compliant. Payment of penalty shall not relieve any persons from fully complying with the requirements of this Code in the execution of the work. The following penalties shall . be imposed: 1. If a designed wet weather erosion control plan is not submitted as prescribed in Section A 13: Grading Permit Volume Penalty �gAKF9 Page 31 of 46 Pages o NT U O ORIGINAL 1- 10,000 cubic yards (1- 7645.5 m3) $50.00 1- 10,000 cubic yards (1- 7645.5 m3) 1per per day 10,001 - 100,000 cubic yards (7646.3 -76455 m3) $250.00 10,001- 100,000 cubic yards (7646.3 -76455 m3) per day More than 100,000 cubic yards (76455 m3) $500.00 More than 100,000 cubic yards (76455 m3) per day 2. If the best management practices for storm water pollution prevention and wet weather erosion control are not installed as prescribed in Section A 13.2, J113.3 and approved by the Building Official: Grading Permit Volume Penalty 1- 10,000 cubic yards (1- 7645.5 m3) 1per $100.00 day 10,001- 100,000 cubic yards (7646.3 -76455 m3) $250.00 per day More than 100,000 cubic yards (76455 m3) $500.00 per day NOTE: See Section J 105 for inspection request requirements. SECTION 4. Chapter 15.07 is hereby added to the Bakersfield Municipal Code as follows: Chapter 15.07 CALIFORNIA MECHANICAL CODE Chapter 15.07.010 Adoption Chapter 15.07.020 Deletions Chapter 15.07.030 Modifications Chapter 15.07.040 Section 303.7 amended —LPG appliances Chapter 15.07.050 Section 508.4 507.2 amended — Clearances for Type I hood Chapter 15.07.060 Section 912.0 amended — Dampers Chapter 15.07.070 Section 310.lamended— Condensate disposal 15.07.010 Adoption. Except as provided in this chapter, that certain Mechanical Code known and designated as the California Mechanical Code, 2016 Edition including Appendixes as adopted by the State and Division II Administration sections 101.0 -107.0 is adopted by reference as modified and amended in this chapter o�0AK,9q Page 32 of 46 Pages U O ORIGINAL and is declared to be the Mechanical Code of the City for the purpose stated therein. 15.07.020 Deletions. The following section of the California Mechanical Code is not adopted as part of this chapter and is deleted: Section 107.0 Board of Appeals. 15.07.030 Modifications The sections of the California Mechanical Code mentioned in Sections 15.07.040 through 15.07.070 are amended to read as set forth in this chapter. 15.07.040 Section 303.7 amended —LPG appliances. Equipment burning liquefied petroleum gas (LPG) or liquid fuel shall not be located in a pit, attic, an underfloor space, below grade or similar location where vapors or fuel might unsafely collect unless an approved method for the safe collection, removal and containment or disposal of the vapors or fuel is approved. 15.07.050 Section 507.2 amended — Clearances for Type I hood. Section 507.2 is amended by adding a second paragraph to read as follows: Stainless steel wall shield below hood shall maintain 3 inches from protected combustibles. 15.07.060 Section 912.0 amended — Dampers. Section 912.0 is amended by adding a second paragraph to read as follows: Fireplaces installed with gas into the firebox shall have one of the following alterations to the damper: Three one inch diameter holes installed in damper or 1/2 inch stop welded onto damper edge, or remove damper with approval of manufacturer. 15.07.070 Section 310.1 amended — Condensate disposal. pxE Page 33 of 46 Pages o u ORIGIN& Section 310.1 is amended by adding a second paragraph to read as follows: All condensate drains installed in or on commercial structures shall be of metallic pipe and fittings. Condensate drains installed outside residential units shall be metallic pipe when over four (4) feet in developed length. Condensate drains entering residential units shall be installed in ABS, PVC, DWV, or metallic pipe installed in accordance to California Plumbing Code installation standards. SECTION 5. Chapter 15.09 is hereby added to the Bakersfield Municipal Code as follows: Chapter 15.09 CALIFORNIA PLUMBING CODE Chapter 15.09.010 Adoption Chapter 15.09.020 Deletions Chapter 15.09.030 Modifications Chapter 15.09.030 Section 508.3 added - Water heater floor support. Chapter 15.09.040 Section 609.3.1 amended - Installation, Inspection and testing Chapter 15.09.050 Section 609.4 - Testing Chapter 15.09.060 Section 713.4 amended - Sewer required Chapter 15.09.070 Section 1211.3.2 amended - Fuel Gas Piping 15.09.010 Adoption. Except as provided in this chapter, that certain Plumbing Code known and designated as California Plumbing Code 2016 Edition including Appendixes as adopted by the State and Division II Administration section's 101.0.-W3.1 is adopted by reference as modified and amended in this chapter and is declared to be the Plumbing Code of the City for the purpose stated therein. 15.07.020 Deletions. The following section of the California Plumbing Code is not adopted as part of this chapter and is deleted: Section 102.3 - Board of Appeals 15.09.030 Modifications. o gAK4 Page 34 of 46 Pages - ` "GINAL The sections of the California Plumbing Code, 2016 Edition, mentioned in Sections 15.09.040 through 15.09.080 of this chapter, as adopted by reference are modified and amended as provided in Sections 15.09.040 through 15.09.080 of this chapter. 15.09.040 Section 504.3.1 added —Water heater floor support. Add a new paragraph to read: All gas fired water heaters installed on combustible construction shall have floor under water heater made of non - combustible material approved by the Administrative Authority. 15.09.050 Section 609.3 amended — Installation, inspection and testing. Section 609.3 is amended to read as follows: 609.3 No water piping shall be installed within a concrete slab or in the ground under a concrete slab of a building. Exceptions: 1. If required by structural conditions, water piping may be installed in chases, sleeves or ducts with the prior approval of the administrative authority. All piping shall be chased, sleeved or ducted the entire length within a concrete slab or in the ground under a concrete slab of a building. Chases, sleeves or ducts shall extend six )6) inches above grade at both ends. 2. Water piping for swimming pools and /or spas. 15.09.060 Section 609.4 — Testing. Recirculating water for swimming pools shall be constructed and installed under the same standards and requirements as potable water piping. 15.09.070 Section 713.4 amended —Sewer required. Sections 713.4 is amended to read as follows: 713.4 The public sewer may be considered as not being available when such public sewer or any building or any exterior drainage facility connected thereto, is located more than one thousand feet from the nearest property line o``epKe9s,. of any proposed building or exterior drainage facility on any lot or premises, m Page 35 of 46 Pages ORIGINAL which abuts and is served by such public sewer. All permitted septic systems shall meet the requirements of the adopted Kern County Onsite Wastewater Local Area Management Plan (LAMP) and obtain a separate permit from Kern County Environmental Health. Exceptions: 1. If the property to be served by the public sewer is residential and consists of four residential living units or less, the one thousand foot requirement referenced in the previous paragraph may be reduced to two hundred feet. 2. The requirements to connect to public sewer may be waived or modified for residential living units consisting of four residential units or less by the building official when strict compliance may cause extreme hardship in accordance with the Kern County LAMP. 3. There is no requirement to hook up to the public sewer upon annexation and thereafter for existing residences of four units or less and where site conditions allow for septic systems to function in accordance with the Kern County LAMP. 15.09.080 Section 422.2 (3) Separate Facilities Section 422.2 (3) is amended to read as follows: (3) In Business and Mercantile occupancies with a total floor area of 2000 square feet or less one toilet facility designed for the use by no more than one person at a time shall satisfy the requirement for serving customers and employees of both sexes. SECTION 6. Chapter 15.11 is hereby amended to the Bakersfield Municipal Code as follows: Chapter 15.11 CALIFORNIA ELECTRICAL CODE Chapter 15.11.010 Adoption Chapter 15.11.020 Deletions Chapter 15.11.030 Modifications Chapter 15.11.040 Section 80.19(A)(3) added — Application Chapter 15.11.050 Section $0.19(C) amended - Issuance of Permits Chapter 15.11.060 Section 80.19(F)(3) amended — Inspections and approvals Chapter 15.11.070 Section 80.25(E) amended - Disconnection 15.11.010 Adoption. pFepK�9'r.. Page 36 of 46 Pages U � ORIGINAL Except as otherwise provided in this chapter, that certain electrical code known and designated as the California Electrical Code, 2016 Edition including Informative Annex H is adopted as modified pursuant to this chapter. A copy of such code is on file with the building department of the city for use and examination by the public, are adopted as the electrical code of the city, and each provision and portion thereof, except as otherwise in this chapter provided, is referred to and made a part of this chapter to the same effect as if fully set forth in this chapter. 15. 11.020 Deletions The following section of the California Electrical Code is not adopted as part of this chapter and is deleted: Section 80.15 Electrical Board of Informative Annex H Sections 80.23(B)(2) and (13)(3) of Informative Annex H Sections 80.25(C) Notification, and (D) Other Territories of Informative Annex H 15.11.030 Modifications The sections of the California Electric Code, 2016 Edition, mentioned in Sections 15.11.040 through 15.11.070 of this chapter, as adopted by reference are modified and amended as provided in Sections 15.11.040 through 15.11. ? ?? of this chapter 15.11.040 Section 80.19(A)(3) added- Application. Section 80.19 of Informative Annex H is amended by adding Section 80.19(A) (3) to read as follows: (3) Applicant. An application for an electrical permit may be filed (made) by any one of the following: (a) Qualified Installer. A qualified installer is a person, firm or corporation holding a valid Contractor's License to perform such work in this jurisdiction; or (b) Homeowners. The building official may issue to an individual a homeowner's permit authorizing said individual to install, alter, change or repair any electrical wiring, devices, appliances, apparatus or equipment in, on o6,OPK4 Page 37 of 46 Pages i o '�IGINAL about a single family dwelling of which said individual is owner and in which he resides or intends to reside, but not elsewhere, provided that electrical work authorized under any such homeowner's permit shall be done personally by the owner. If the electrical work performed under the homeowner's permit does not comply with the requirements of this code and if the corrections are not made as required by the Building Department, then the deficiencies shall be corrected by a State licensed electrical contractor under a separate permit. (c) Emergency Work, Emergency electrical work for the protection of persons or property shall have a permit obtained within one business day of commencing such work. 15.11.050 Section 80.19(C) amended - Issuance of Permits. Section 80.19(C) (1) & (2) of Informative Annex H is amended to read as follows: (c) Issuance of Permits. The authority having jurisdiction shall be authorized to establish and issue permits, certificates, notices, and approvals, or orders pertaining to electrical safety hazards pursuant to 80.23, except that no permit shall be required to execute the electrical work specified in the following: 1) Listed cord and plug connected temporary decorative lighting. 2) Reinstallation of attachment plug receptacles and general use snap switches but not the outlets therefore. 3) Replacement of branch circuit overcurrent devices of the required capacity in the same location. 4) Repair or replacement of non - emergency luminaires of 50 pounds or less. 15.11.060 Section 80.19(F)(3) amended — Inspections and approvals. Section 80.19(F) (3) of Informative Annex H is amended to read as follows: (3) When any portion of the electrical installation within the jurisdiction of an Electrical Inspector is to be hidden from view by the permanent placement of parts of the building, the person, firm, or corporation installing the equipment shall notify the Electrical Inspector, and such equipment shall not be concealed until it has been approved by the Electrical Inspector, provided that on large installations, where the concealment of equipment proceeds continuously, the person, firm, or corporation installing the equipment shall give the Electrical Inspector due notice in advance, and inspections shall be made periodically during the progress of the work. o�gpK,,q Page 38 of 46 Pages 6 (`.=71GINAL 15.11.070 Section 80.25(E) amended - Disconnection Section 80.25(E) of Informative Annex H is amended to read as follows: Where a connection is made to an installation that has not been inspected, as outlined in the preceding paragraphs of this section, the supplier of electricity shall immediately report such connection to the Chief Electrical Inspector. If, upon subsequent inspection, it is found that the installation is not in conformity with the provisions of Informative Annex H, the Chief Electrical Inspector shall notify the person, firm, or corporation making the installation to rectify the defects and, if such work is not completed within 10 business days, the authority having jurisdiction shall have the authority to cause the disconnection of that portion of the installation that is not in conformity. SECTION 7. Chapter 15.13 is hereby added to the Bakersfield Municipal Code as follows Chapter 15.13 CALIFORNIA EXISTING BUILDING CODE Chapter 15.13.010 Adoption 15.13.010 Adoption. The 2016 California Existing Building Code based on the 2015 International Existing Code is adopted by reference and enacted as the existing building code of the city for the purpose stated therein. SECTION 8. Chapter 15.15 is hereby added to the Bakersfield Municipal Code as follows: Chapter 15.15 CALIFORNIA HISTORICAL BUILDING CODE Chapter 15.15.010 Adoption 15.15.010 Adoption. The 2016 California Historical Building is adopted by reference and enacted as the historical building code of the city for the purpose stated therein. SECTION 9. Chapter 15.17 is hereby added to the Bakersfield Municipal Code as follows: Chapter 15.17 2010 CALIFORNIA RESIDENTIAL CODE okOAKf,9m Page 39 of 46 Pages v o ORIGINAL 15.17.010 Adoption. 15.17.020 Deletions. 15. 17.030 Modifications. 15.17.040 Section R108 amended -Fees. 15.17.050 Section R401 amended - General Foundations. 15.17.060 Section R403 amended - Footings 15.17.070 Section R404 amended - Foundation and Retaining Walls 15. 17.080 Section R501 amended - Floors General 15. 17.090 Section R503 amended - Floor Sheathing 15.17.100 Section R602 amended - Wood wall Framing 15.17.110 Section R606 amended - General Masonry Construction 15.17.120 Section R803 amended - Roof Sheating Chapter 15.17.010 Adoption. Except as provided in this chapter, that certain building code known and designated as the California Residential Code, 2016 Edition including Chapter 1, Division II, and Appendix H, which code was based on the 2015 International Residential Code as published by the International Code Council and, a copy of which is on file in the building department of the city for use and examination by the public, and each portion and provision thereof, is adopted by reference as modified and amended in this chapter and is declared to be the residential building code of the city for the purpose of regulating the erection, construction, enlargement, alteration, repair, moving, removal, demolition, conversion, occupancy, use, height and maintenance of all residential structures and certain equipment therein specifically regulated within the incorporated limits of issuance of permits and the collection of fees thereof. 15.17.020 Deletions. The following sections, tables and chapters of the California Residential Code, 2016 Edition, or appendix thereto, are not adopted as part of the ordinance codified in this chapter and are deleted: Chapter 1 Division II, Section R112 — Board of Appeals Appendix A - Sizing and Capacities of Gas Piping Appendix B - Sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category I Appliances and Appliances Listed for use with Type B Vents. Appendix C - Exit Terminals of Mechanical Draft and Direct -Vent Venting Systems s Page 40 of 46 Pages U � ORIGINAL Appendix D - Recommended Procedure for Safety Inspection of an Existing Appliance Installation. Appendix E - Manufactured Homes Used as Dwellings Appendix F - Radon Control Methods Appendix G - Swimming Pools, Spas and Hot Tubs Appendix I - Private Sewage Disposal Appendix J - Existing Buildings and Structures Appendix K - Sound Transmission Appendix L - Permit Fees Appendix M - Home Day Care - R3 Occupancy Appendix N - Venting Methods Appendix O - Automatic Vehicular Gates Appendix P - Sizing of Water Piping System Appendix Q - ICC International Residential Code Electrical Provisions /National Electrical Code Cross Reference. 15.17.030 Modifications. The sections of the California Residential Code 2016 Edition, Appendix H mentioned in Sections 15.17.040 through 15.17.120 of this chapter, as adopted by reference, are amended as provided in Sections 15.17.040 through 15.17.120 of this chapter. 15.17.040 Section RI 08 amended - Fees. Subsection R 108.2 is amended to read as follows: All plan check and permit fees shall be assessed in accordance with the Master Fee Schedule adopted by the City. Subsection R108.5 is amended to read as follows: oepKF9sT > m Page 41 of 46 Pages � 6 ORIGINAL R108.5 Refunds. See BMC 15.05.050 Section 109.6 Refunds 15.17.050 Section R401 amended -General • Foundations. Second paragraph of subsection R401.1 is amended to read as follows: Wood foundations in Seismic Design Category Do, Di, or D2 shall not be permitted. Exception: In non - occupied, single -story. detached storage sheds and similar uses other than carport or garage, provided the gross floor area does not exceed 240 square feet, the plate height does not exceed 12 feet in height above the grade plane at any point. and the maximum roof projection does not exceed 24 inches. 15.17.060 Section R403 amended - Footings. Section R403.1.2 is amended to read as follows: R403.1.2 Continuous footing in Seismic Design Categories Do, D, and D2. The braced wall panels at exterior walls of buildings located in Seismic Design Categories Do, Di, and D2 shall be supported by continuous footings. All required interior braced wall panels in buildings shall be supported by continuous footings. Second paragraph of Subsection R403.1.3 is added to read as follows: All concrete floor slabs poured on earth, for buildings of group R occupancies, including garage floor slabs, shall be reinforced with a welded wire fabric of 6 x 6 -10 /10 minimum weight or an approved equal. 15. 17.070 Section 404 amended - Foundation and Retaining Walls. Subsection R404.2 is amended to read as follows: R404.2 Wood foundation walls. Wood foundation walls shall be constructed in accordance with the provisions of Sections R404.2.1 through R404.2.6 and with the details shown in Figures R 403.1(2) and R403.2(3). Wood foundation walls shall not be used for structures located in Seismic Design Category Do, Di or D2. 15.17.080 Section R501 amended - Floors • General. Subsection R501.1 is amended to read as follows: oFepKF9s T Page 42 of 46 Pages v o ORIGINAL R501.1 Application. The provision of this chapter shall control the design and construction of the floors for all buildings including the floors of attic spaces used to house mechanical or plumbing fixtures and equipment weighing less than 400 lbs. 15.17.090 Section R503 amended - Floor Sheathing. Subsection R503.2.4 added to read as follows: 8503.2.4 Openings in horizontal diaphragms. Openings in horizontal diaphragms with a dimension perpendicular to the joist that is greater than 4 feet (1.2 m) shall be constructed in accordance Section 2308.11.3.3 of the California Building Code. Openings shall be further limited in accordance with Section R301.2.2.2.5. 15.17.100 Section R602 amended -Wood Wall Framing. Exception to subsection R602.3.2 amended to read as follows: Exception: In other than Seismic Design Category Do, Di, or Dz. A single top plate may be installed in stud walls, provided the plate is adequately tied at joints, corners and interesting walls by a minimum 3inch -by -6 -inch by a 0.036 - inch -thick (76 mm by 152 mm by 0.914 mm) galvanized steel plate that is nailed to each wall or segment of wall by six 8d nails on each side, provided the rafters or joists are centered over the studs with a tolerance of no more than 1 inch (25 mm). The top plate may be omitted over lintels that are adequately tied to adjacent wall sections with steel plates or equivalent as previously described. 15.17.110 Section R606 amended - General Masonry Construction. Subsection R606.2.4 amended to read as follows: R606.2.4 Parapet Walls. Unreinforced solid masonry parapet walls shall not be less than 8 inches (203 mm) thick and their height shall not exceed four time their thickness. Unreinforced hollow unit masonry parapet walls shall not be less than 8 inches (203 mm) thick, and their height shall not exceed three times their thickness. Masonry parapet walls in areas subject to wind loads of 30 pounds per square foot (1.44 kPa) or located in Seismic Design Category Do, Di or Dz or on Townhouses in Seismic Design Category C shall be shall be reinforced in accordance with section R606.12. 15. 17.120 Section R803 added - Roof Sheathing. Subsection R803.2.4 added to read as follows: o``0llKe9' Page 43 of 46 Pages G ORIGINAL R803.2.4 Openings in horizontal diaphragms. Openings in horizontal diaphragms shall conform with Section R503.2.4. SECTION 10. Chapter 15.19 is hereby added to the Bakersfield Municipal Code as follows: Chapter 15.19. CALIFORNIA GREEN BUILDING STANDARDS CODE 15.19.010 Adoption 15.19.020 Modifications. 15.19.030 Definitions. 15.19.040 Section 5.106.4 amended - Bicycle Parking Chapter 15.19.010 Adoption 15.19.010 Adoption The 2016 California Green Building Standards Code is adopted by reference and enacted as the California Green Code of the city for the purpose stated therein. Except as provided in this chapter, that certain Green Building Standards Code known and designated as the California Green Building Standards Code, 2016 Edition including Appendix is adopted by reference as modified and amended in this chapter and is declared to be the Green Code of the City for the purpose stated therein. 15.19.020 Modifications The sections of the California Green Code mentioned in Sections 15.19.030 through 15.19.050 15.19.040 are amended to read as set forth in this chapter. 15.19.030 Section 202 amended - Definitions. Section 202 amended by adding definition of Sustainability to read as follows: Sustainability. Consideration of present development and construction impacts on the community, the economy, and the environment without compromising the needs of the future. 040pKF9'�.. m Page 44 of 46 Pages =� o nz1�GINAI 15.19.040 Section 5.106.4 amended - Bicycle Parking Subsection 5.106.4 Bicycle Parking amended to read as follows: 5.106.4 Bicycle Parking For buildings within the authority of California Building Standards Commission as specified in Sections 103 and Multifamily dwellings, comply with Section 5.106.4.1. For buildings within the authority of the Division of the State Architect pursuant to Section 105, comply with Section 5.106.4.2. SECTION 11. This Ordinance shall be posted in accordance with the provisions of the Bakersfield Municipal Code and shall become effective thirty (30) days from and after the date of its passage. — 00000 - - -- eAKP4 o '!n Page 45 of 46 Pages t-- o ORIGINAL I HEREBY CERTIFY that the foregoing Ordinance was passed and adopted by the Council of the City of Bakersfield at a regular meeting thereof held on NOV 0 2 2016 by the following vote: ✓ ✓ V� ✓ ✓ ✓ / AYES: COUNCILMEMBER'. RIVERA, MAXWEL WE SMITH, HANSON, SULLIVAN, PARLIER COUNCILMEMBER: ABSTAIN: COUNCILMEMBER: ABSENT: COUNCILMEMBER: ROBERTA GAFFORD, C CITY CLERK and EX OF CIO Clerk of the Council of the City of Bakersfield APPROVED: NOV 02 HARVEY L. HALL, Mayor City of Bakersfield APPROVED AS TO FORM: VIRGINIA GENNARO City Attorney By: Andrew Heglun Deputy City Attorney �gAKF9 C ; %Ua Wck \D P\l1- M- BUIMmy C..M1 Hon Code Woncere.doc m+ m Page 46 of 46 Pages 1u?InIAL AFFIDAVIT OF POSTING DOCUMENTS STATE OF CALIFORNIA) ) ss. County of Kern ) ROBERTA GAFFORD, being duly sworn, deposes and says: That she is the duly appointed, acting and qualified City Clerk of the City of Bakersfield; and that on the 7th day of November. 2016 she posted on the Bulletin Board at City Hall, a full, true and correct copy of the following: Ordinance No. 4678, passed by the Bakersfield City Council at a meeting held on the 2nd day of November, 2016 and entitled: AN ORDINANCE AMENDING CHAPTER 15.04 OF THE BAKERSFIELD MUNICIPAL CODE RELATING TO BUILDING AND CONSTRUCTION AND ADOPTING THE 2016 CALIFORNIA BUILDING CODE, 2016 CALIFORNIA MECHANICAL CODE, 2016 CALIFORNIA PLUMBING CODE, 2016 CALIFORNIA ELECTRICAL CODE, 2016 CALIFORNIA EXISTING BUILDING CODE, 2016 CALIFORNIA HISTORICAL BUILDING CODE, 2016 CALIFORNIA RESIDENTIAL CODE AND 2013 CALIFORNIA GREEN BUILDING CODE BY AMENDING CHAPTERS 15.04, 15.05, 15.07, 15.09, 15.11, 15.13, 15.15, 15.17, AND 15.19 THERETO. ROBERTA GAFFORD City Clerk and Ex Officio of the Council of the City off Bakersfield By: % � t DEPUTY City Clerk o�`eAKF9s � m U O ORIGINAL