Loading...
HomeMy WebLinkAboutFire Safety 11-7-16�a BAKERSFIELD FIRE DEPARTMENT FIRE PREVENTION INSPECTION 't Prevention Services B E R S F I D FIRE 2101 H Street. Al{tTM T Bakersfield. CA 93301. Phone: 661- 326 -3979 9 Fax: 661- 852 -21.71 DISTRICT. BLOCK NO. DATE FEE. ' FACILITY ADDRESS `CITY, STATE, ZIP FACILITY NAME { G R'S NAME °t'.Y YI PH NO. _ :.... g xef� s. 1�.""• ! =4 . L, !..i BUSINES'S OWNER'S NAME AND ADDRESS �: _ CITY, STATE, ZIP PH NO. BILL To: (IF DIFFERENT FROM ABOVE) NAME; ADDRESS CITY, STATE, ZIP; PH No. OCC TYPE OCC LOAD NO. OF FLOORS HIGH RISE BLDG RISER DATE 13 .YES NO. CORRECT ALL VIOLATIONS vzotaTZOn REQUIREMENTS .CHECKED BELOW N.O. 1 Remove anal: safely dispose . of a1.1 hazard,ou.s refuse, and dry vegetation on the above premises (CFC COMBUSTIBLE WASTE / 'DRY 304.1 VEGETATION 2 Provide non - combustible containers w.ith tight. fitting' lids for the storage of combustible waste and rubbish pending'.its safe 'disposal. (CFC 304.3.2) Note:. applies to co.ntaine'rs over 40 gallons... COMBUSTIBLE, STORAGE . 3: Relocate combustible storage to provide at least 3 feet clearance around, motor ,fuse b'ox /fire door (CFC .60513) . 4 Relocate fire extinguisher(§) so that they will be in a conspicuous I.ocation,;han.g.irirg on brackets with the. top to. the extinguisher not more than.5 feet above the floor. (CFC 906.5. &.906.9) EXTINGUISHERS 5 Provide and in'sta'll (am'ou'nt) _____ approved (type & size). -------------- _ -_ portable fire. extinguisher to be immediately,accessible for use in (area) __ ____ _ (CFC TABLE 906.3(1)).. 5 Re'- charge al.l fire .extinguishers. Fire extinguishers shall be .serviced at least once each year, an.d /or after each use, by a person having a valid license or.certificate. (CFC 906:2) j Provide and maintain "EXIT" sign(s)-with letters .6 or more inches in height over each required exit SIGNS (door /window) to fire escape: (CFC 1011) 8 Provide "and maintain, appropriate numbers on a contrasting' background and visible from the street to indicate the _correct 'address of the building. (CFC':505:1) g Rep.air all (cracks /holes /openings). in plaster in (location) ------------------------------------ FIRE DOORS Pl.as.tering shall return the surface to.its original fire resistive condition.. (CFC 703.1) FIRE SEPARATIONS 10 Remove /repair (item & I o c a t i o n) - - -- ----------=--=---------= ------------ --------------- Self- closing' doors shall be designed to close by gravity,. or by the action of a. mechanical .device, or by an approved smoke and heat sensitive device. Self - closing doors shall have no 'attachments capable of;. preventing the operation of the 'closing device. (CFC 203.2) 11 Remove all obstruction from hallway's. Maintain a'll means of egress free of any storage. (CFC 1028.3) EXITS 12 Provide .a contrasting colored and permanently installed" electric light over or near required `exit ___ ___ to, clearly indicate it as an exit.. CFC' 1006.3 location) —=---=---------- - - - - -- (. ) STORAGE Remove all storage and /or other obstructions from fire escape landings and stairways.,stair shafts., (Fire 13 escapes /stair shafts a.re.to'b:e maintained free from obstructions: at all times.) (CFC 1003.6) 14 Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved ELECTRICAL APPLIANCES electrical outlets where needed. (CFC 605.5) 15.. Remove multiple attachment cords .from specific electrical convenience outlet' (one. paug pe,r outlet) (CFC 605.4) OUTDOOR BURNING 15 Recreational fires or open burnin . CFC 307.1 FIREWORKS. 17 Violations of Section (CFC 560$.1) &8.44.040 (B.M.C.). OTHER' - 18/ r t 1 L' ' .1 +%1 L. CORRECTION DATE Correct the violations noted above by: LEGEND:' C.F.C. CALIFORNIA.FIRE'CODE • C.B.C. CALIFORNIA BUILDING CODE. CUSTOMER: (Signature) (Please Print Name Legibly, Title) B.M.C. BAKERSFIELD MUNICIPAL CODE N.F.P.A. " NATIONAL FIRE PROTECTION INSPECTOR: r� t NO.: r ASSOCIATION. N.E.C. NATIONAL ELECTRIC CODE'