Loading...
HomeMy WebLinkAbout12500 Stockdale Hwy - Drainage Study RevisionEagle Oaks Specialty Care Center (ON-SITE ONLY) BASIN SIZING CALCULATIONS Required Sump Capacity based on Approved H/H Study* * Required Sump Capacity =12.31 AC-FT * Provided Sump Capacity = 12.53 AC-FT * Drainage Area C1 (Undeveloped) PROVIDED AREA (A) =31.21 acres RUNOFF COEFFICIENT (C)= 0.9 Approved Provided Sump Capacity for Area C1 = 0.15 x C x A =4.21 AC-FT *Per Approved Drainage Study for Tract 6250 & 6281 Required Sump Capacity for Eagle Oaks Specialty Care Center TABLE OF RUNOFF COEFFICIENTS On-Site Stockdale Hwy C x A = AREAS A-P AREA 10 R-1, 6000 SF 0.42 R-1, 6750 SF 0.4 R-1, 7500 SF 0.38 R-1, 10000 SF 0.34 R-1, 15000 SF 0.27 R-2 0.55 R-3, R-4, M-H 0.8 Commercial 0.9 8.62 7.76 Industrial 0.8 Parks 0.15 Grasslands, Type A Soil 0.15 Grasslands, Type B Soil 0.25 Grasslands, Type C Soil 0.35 Grasslands, Type D Soil 0.45 Pavement, drives & roofs 0.95 0.97 0.96 1.83 Backyards 0.05 Lawn-landscape 2% slope 0.17 Lawn-landscape 2-7% slope 0.22 Lawn-landscape 7% slope 0.35 n C x A =9.59 On-Site Stockdale Hwy Total 9.59 0.96 =Acres 10.55 Required Sump Capacity = 0.15 x C x A =0.15 X n C x A =1.44 AC-FT Remaining Sump Capacity = Undeveloped Commercial Area (Area C1) - Eagle Oaks Specialty Care Center Remaining Sump Capacity = 2.77 AC-FT STOCKDALE HIGHWAY AL L E N R O A D EXISTING GAS STATION VACANT LOT STOCKDALE HIGHWAY J E W E T T A A V E N U E Know what's R TRACT 6281 TRACT 6250 NOTE: INSTALL OUTLET STRUCTURE PER C.O.B. STD. DTL. D-11