HomeMy WebLinkAboutTract 6760 - Drainage StudyTract No. 6760
DRAINAGE STUDY
2
Table of Contents
1.0 PURPOSE ...................................................................................................................3
2.0 GUIDELINES ...............................................................................................................3
3.0 DESIGN APPROACH .................................................................................................3
4.0 CONCLUSION AND RECOMMENDATIONS .............................................................5
..................................................................................................................back of report
Soil Map ....................................................................................................back of report
Hydrology Calculations..............................................................................back of report
Inlet Sizing Calculations ............................................................................back of report
Hydraulics Calculations and Profiles .........................................................back of report
Basin Exhibit ..............................................................................sleeve in back of report
Drainage Exhibit .........................................................................sleeve in back of report
Reference ..................................................................................................back of report
Reference ..................................................................................................back of report
4.
Tract No. 6760
DRAINAGE STUDY
3
1.0 PURPOSE
The purpose for this drainage study is as follows:
1. To provide a storm drainage system in accordance with the City of Bakersfield
requirements and guidelines.
2. To provide an economical and reasonable design for storm drain conveyance and
disposal facilities.
2.0 GUIDELINES
The following design standards were used in the development of this study:
1. Initial times of concentration (roof to gutter) are 15 minutes for R-1 Development.
2. Soil Group A is primarily located throughout the site:
127— Granoso sandy loam, 0 to 2 percent slopes, overwash
174— Kimberlina fine sandy loam, 0 to 2 percent slopes MLRA 17
3. The runoff coefficients used are:
0.27 - R-1, 15,000 S.F.
0.38 - R-1, 7,500 S.F.
4. Rainfall intensity curves used are those shown on Plate D-1 of the City of Bakersfield,
Subdivision & Engineering Manual.
3.0 DESIGN APPROACH
The contributing areas to the existing storm drain system are all zoned residential and therefore
were modeled as such.
The project area for these improvements is dictated by the flat terrain that is present. More
specifically the improvements are bounded to the east by Parcel A of Parcel Map 3790, to the
north by Tract 6290, to the south by Taft Highway, and to the west by Tract 6491. The property
was previously vacant and had a natural courses of drainage towards the middle of the site.
The proposed project will construct 33 residential lots ranging in size from 8,100 sq. ft. to 16,713
sq. ft. and an existing residential lot adjacent to Taft Highway. The proposed drainage differs from
the Approved Drainage Study for Tract 6491 by using a lower runoff coefficient and the addition
of an existing residence to the watershed. Drainage Areas along Boise River Drive will drain
midway between Agassiz Rock Way and the end of each cul-de-sac. Catch basins #1 and #2 will
collect the discharge produced by site areas along north of the T-intersection of Boise River Road
and Agassiz Rock Way. The existing residential lot, off of Taft Highway, will be incorporated into
Drainage Area 3 which will have a composite runoff coefficient. Although this lot drains into CB8,
the analysis is more conservative to include this area at the upstream end of the pipe network
than further downstream at the existing inlet. Drainage Areas 3 and 4 will discharge into two catch
basins (CB #3 and #4) south of the Boise River Road and Agassiz Rock Way T-intersection.
Analysis for the proposed improvements along Taft Highway was included as part of Area 8A in
the Approved Drainage Study for Tract 6491. (See Reference Section for Drainage Study Map)
The flows for the sizing of the pipes were estimated utilizing the City of Bakersfield Rational
Method in accordance with the Subdivision Standards. Flows were computed for the 10-year
event using the formula Q = CIA, where Q is the flow in cubic feet per second, C is the runoff
Tract No. 6760
DRAINAGE STUDY
4
coefficient, I is the intensity in inches per hour, and A is the catchment’s area in acres. The storm
drain system and the curb capacities were calculated based the 10-year storm event.
The existing retention basin is located at the southwest corner of Tract 6491 and handles all of
the discharge from Tract 6760 and the existing residential lot. The existing basin volume was
calculated in the Approved Drainage Study for Tract 6757 and 6758 which does included the
drainage areas for Tract 6757, 6758, and 6491.
The rational method for the 10-year event was performed using Autodesk Hydraflow Storm
Sewers Extension 2015. This program routes the flows and calculates the HGL for the system.
The program has the ability to calculate the time of concentrations, but it also allows you to enter
your own time. A spreadsheet similar to the curb capacity spreadsheet was used to determine the
initial time of concentrations in a 10-year event. The flows from the 10-year event were calculated
and routed. Starting HGL at the existing stub was at an elevation of 341.82 which was
established by the Approved Drainage Study for Tract 6491 per CB5.
4.0 CONCLUSION AND RECOMMENDATIONS
The flows from the 10-year event were calculated and routed. All the pipes in this system were
sized to be 18” RCP and is not less than 0.5’ below the proposed grade at any manhole or inlet.
The required sump capacity for Tract 6760 and an existing residential lot is 0.54 ac-ft. Based on
the Approved Drainage Study for Tract 6491, the required sump capacity for Area 5 was
calculated at 0.55 ac-ft which is 0.01 ac-ft greater than the current analysis. Thus the previously
analyzed required sump capacity is about the same volume for the proposed required sump. The
coefficient values are provided for each area and the calculations for the required volumes are
shown below. (See Reference Section for Existing Basin Capacity)
Area Acres Coefficient C x A
Approved TRACT 6491 See Approved Drainage Study for Tract 6491
AREA 5 8.71 0.42 0.35
AREA 5 Ʃ(CXA) =3.66
TOTAL (AC)8.71 VOLUME REQUIRED (AF) =0.55
Proposed TRACT 6760
R-1, 7500 SF 8.92 0.38 3.39
R-1, 15000 SF 0.71 0.27 0.19
TRACT 6536 Ʃ(CXA) =3.58
TOTAL (AC)9.63 VOLUME REQUIRED (AF) =0.54
The Basin Exhibit, part of this study, shows the existing basin based with the proposed
improvements based on Approved Drainage Study for Tract 6757 and 6758. This basin will be
deepened by 0.55 feet to account for the proposed improvements. The basin will have a new
water depth of 9.0’ by holding the existing design water surface elevation at 343.0. The updated
basin will be able to store 11.99 AF of runoff with required volume for all tracts is 11.97 AF which
has an excess volume of 0.02 AF.
Tract No. 6760
DRAINAGE STUDY
5
Vicinity Map
NOT TO SCALE
SOIL MAP
Hydrologic Soil Group—Kern County, California, Northwestern Part
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
2/29/2016
Page 1 of 4
39
0
4
5
9
0
39
0
4
6
4
0
39
0
4
6
9
0
39
0
4
7
4
0
39
0
4
7
9
0
39
0
4
8
4
0
39
0
4
8
9
0
39
0
4
9
4
0
39
0
4
9
9
0
39
0
5
0
4
0
39
0
4
5
9
0
39
0
4
6
4
0
39
0
4
6
9
0
39
0
4
7
4
0
39
0
4
7
9
0
39
0
4
8
4
0
39
0
4
8
9
0
39
0
4
9
4
0
39
0
4
9
9
0
39
0
5
0
4
0
312140 312190 312240 312290 312340 312390 312440
312090 312140 312190 312240 312290 312340 312390 312440
35° 16' 15'' N
11
9
°
3
'
5
7
'
'
W
35° 16' 15'' N
11
9
°
3
'
4
2
'
'
W
35° 16' 0'' N
11
9
°
3
'
5
7
'
'
W
35° 16' 0'' N
11
9
°
3
'
4
2
'
'
W
N
Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 11N WGS84
0 100 200 400 600
Feet
0 30 60 120 180
Meters
Map Scale: 1:2,310 if printed on A portrait (8.5" x 11") sheet.
MAP LEGEND MAP INFORMATION
Area of Interest (AOI)
Area of Interest (AOI)
Soils
Soil Rating Polygons
A
A/D
B
B/D
C
C/D
D
Not rated or not available
Soil Rating Lines
A
A/D
B
B/D
C
C/D
D
Not rated or not available
Soil Rating Points
A
A/D
B
B/D
C
C/D
D
Not rated or not available
Water Features
Streams and Canals
Transportation
Rails
Interstate Highways
US Routes
Major Roads
Local Roads
Background
Aerial Photography
The soil surveys that comprise your AOI were mapped at 1:24,000.
Warning: Soil Map may not be valid at this scale.
Enlargement of maps beyond the scale of mapping can cause
misunderstanding of the detail of mapping and accuracy of soil line
placement. The maps do not show the small areas of contrasting
soils that could have been shown at a more detailed scale.
Please rely on the bar scale on each map sheet for map
measurements.
Source of Map: Natural Resources Conservation Service
Web Soil Survey URL: http://websoilsurvey.nrcs.usda.gov
Coordinate System: Web Mercator (EPSG:3857)
Maps from the Web Soil Survey are based on the Web Mercator
projection, which preserves direction and shape but distorts
distance and area. A projection that preserves area, such as the
Albers equal-area conic projection, should be used if more accurate
calculations of distance or area are required.
This product is generated from the USDA-NRCS certified data as of
the version date(s) listed below.
Soil Survey Area: Kern County, California, Northwestern Part
Survey Area Data: Version 8, Sep 9, 2015
Soil map units are labeled (as space allows) for map scales 1:50,000
or larger.
Date(s) aerial images were photographed: Aug 13, 2013—Oct 23,
2013
The orthophoto or other base map on which the soil lines were
compiled and digitized probably differs from the background
imagery displayed on these maps. As a result, some minor shifting
of map unit boundaries may be evident.
Hydrologic Soil Group—Kern County, California, Northwestern Part
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
2/29/2016
Page 2 of 4
Hydrologic Soil Group
Hydrologic Soil Group— Summary by Map Unit — Kern County, California, Northwestern Part (CA666)
Map unit symbol Map unit name Rating Acres in AOI Percent of AOI
127 Granoso sandy loam, 0
to 2 percent slopes,
overwash
A 2.3 26.4%
174 Kimberlina fine sandy
loam, 0 to 2 percent
slopes MLRA 17
A 6.3 73.6%
Totals for Area of Interest 8.6 100.0%
Description
Hydrologic soil groups are based on estimates of runoff potential. Soils are
assigned to one of four groups according to the rate of water infiltration when the
soils are not protected by vegetation, are thoroughly wet, and receive precipitation
from long-duration storms.
The soils in the United States are assigned to four groups (A, B, C, and D) and
three dual classes (A/D, B/D, and C/D). The groups are defined as follows:
Group A. Soils having a high infiltration rate (low runoff potential) when thoroughly
wet. These consist mainly of deep, well drained to excessively drained sands or
gravelly sands. These soils have a high rate of water transmission.
Group B. Soils having a moderate infiltration rate when thoroughly wet. These
consist chiefly of moderately deep or deep, moderately well drained or well drained
soils that have moderately fine texture to moderately coarse texture. These soils
have a moderate rate of water transmission.
Group C. Soils having a slow infiltration rate when thoroughly wet. These consist
chiefly of soils having a layer that impedes the downward movement of water or
soils of moderately fine texture or fine texture. These soils have a slow rate of water
transmission.
Group D. Soils having a very slow infiltration rate (high runoff potential) when
thoroughly wet. These consist chiefly of clays that have a high shrink-swell
potential, soils that have a high water table, soils that have a claypan or clay layer
at or near the surface, and soils that are shallow over nearly impervious material.
These soils have a very slow rate of water transmission.
If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is
for drained areas and the second is for undrained areas. Only the soils that in their
natural condition are in group D are assigned to dual classes.
Hydrologic Soil Group—Kern County, California, Northwestern Part
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
2/29/2016
Page 3 of 4
Rating Options
Aggregation Method: Dominant Condition
Component Percent Cutoff: None Specified
Tie-break Rule: Higher
Hydrologic Soil Group—Kern County, California, Northwestern Part
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
2/29/2016
Page 4 of 4
HYDROLOGY CALCULATIONS
CITY OF BAKERSFIELD RATIONAL METHOD
(In accordance with City of Bakersfield Standards)
TABLE OF RUNOFF COEFFICIENTS
R-1, 6000 SF 0.42
JOB TITLE:Tract 6760 R-1, 6750 SF 0.4
DATE:Nov-16 R-1, 7500 SF 0.38
R-1, 10000 SF 0.34
Rational Values:R-1, 15000 SF 0.27
Event: 10 YEAR Values: 5, 10, 50 R-3, R-4, M-H 0.8
M.A.P. 6 in./yr. Values: 6, 10, 15, 20, 25, 30 Commercial 0.9
Industrial 0.8
Curve Values Parks 0.15
a: 2.38 I=a+bTc (Tc<20min.) Grasslands, Type A Soil 0.15
b: -0.058 Grasslands, Type B Soil 0.25
P60: 0.550 I=K1*(6.02*Tc)^(0.17*LN(p60/K1) Grasslands, Type C Soil 0.35
K1: 40.00 (Tc>=20min.) Grasslands, Type D Soil 0.45
Pavement, drives & roofs 0.95
Backyards 0.05
Lawn-landscape 2% slope 0.10 0.17
Lawn-landscape 2-7% slope 0.15 0.22
Lawn-landscape 7% slope 0.20 0.35
SUBAREA C I A rslt Tc L dH Sg Q Street V Trial Tc Roof to Tm Curb D
NAME Runoff Intensity Total Time Length Elev. Gutter Flow Type Vel. MIN. Gutter Travel Cap Pipe
Coef. IN/HR Area Conc. Feet Diff. Slope CFS FPS Time Time In Dia.
AC. MIN. Feet Ft/Ft MIN. MIN. In.
Input
AREA 1 0.38 1.43 2.11 16.44 180 0.82 0.46% 1.14 60 2.08 16.44 15 1.44 3.10
PIPE 4 23.65 1.14 0.65 0.61 18
17.05
AREA 2 0.38 1.42 2.03 16.45 180 0.82 0.46% 1.10 60 2.07 16.45 15 1.45 3.07
PIPE 3 26.00 1.10 0.62 0.70 18
17.15
PIPE 2 0.38 1.38 4.14 261.63 2.18 1.23 17.15 3.54 18
20.69
0.38 2.83
0.27 0.71
AREA 3 0.36 1.37 3.54 17.25 300 1.42 0.47% 1.74 60 2.22 17.31 15 2.25 3.49
PIPE 6 14.00 1.74 0.99 0.24 18
17.55
AREA 4 0.38 1.34 1.95 17.94 360 1.73 0.48% 0.99 60 2.04 17.94 15 2.94 2.99
PIPE 7 26.30 0.99 0.56 0.78 18
18.72
PIPE 5 0.37 1.29 5.49 394.11 2.60 1.47 18.72 4.47 18
23.19
PIPE 1 0.37 1.09 9.63 159.01 3.92 2.22 23.19 1.20 18
24.39
Required Sump Capacity = 0.15 x C x A =0.54 ac-ft 0.55 ac-ft
C = 0.37 A= 9.63 acres C = 0.42 A= 8.71 acres
Tract 6760
CALCULATIONS & RESULTS
AREA 3
BREAKDOWN Existing R-1, 15,000 SF (APN:532-040-03)
Proposed Tract 6760 (Lots 25-33)
Required Sump Capacity from (Area 5 of Approved Study) = 0.15 x C x A =
Hydrology_10_yr - Copy
McIntosh Associates
2001 Wheelan Ct
Bakersfield, CA 93309 10 yr Calc
2.25
.49
INLET SIZING CALCULATIONS
Inlet Report
Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc.Thursday, Nov 17 2016
Catch Basin #1 - Drainage Area 1
Curb Inlet
Location = Sag
Curb Length (ft) = 3.50
Throat Height (in) = 4.50
Grate Area (sqft) = -0-
Grate Width (ft) = -0-
Grate Length (ft) = -0-
Gutter
Slope, Sw (ft/ft) = 0.020
Slope, Sx (ft/ft) = 0.083
Local Depr (in) = 2.00
Gutter Width (ft) = 2.00
Gutter Slope (%) = -0-
Gutter n-value = -0-
Calculations
Compute by: Known Q
Q (cfs) = 1.14
Highlighted
Q Total (cfs) = 1.14
Q Capt (cfs) = 1.14
Q Bypass (cfs) = -0-
Depth at Inlet (in) = 4.03
Efficiency (%) = 100
Gutter Spread (ft) = 3.56
Gutter Vel (ft/s) = -0-
Bypass Spread (ft) = -0-
Bypass Depth (in) = -0-
Inlet Report
Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc.Thursday, Nov 17 2016
Catch Basin #2 - Drainage Area 2
Curb Inlet
Location = Sag
Curb Length (ft) = 3.50
Throat Height (in) = 4.50
Grate Area (sqft) = -0-
Grate Width (ft) = -0-
Grate Length (ft) = -0-
Gutter
Slope, Sw (ft/ft) = 0.020
Slope, Sx (ft/ft) = 0.083
Local Depr (in) = 2.00
Gutter Width (ft) = 2.00
Gutter Slope (%) = -0-
Gutter n-value = -0-
Calculations
Compute by: Known Q
Q (cfs) = 1.10
Highlighted
Q Total (cfs) = 1.10
Q Capt (cfs) = 1.10
Q Bypass (cfs) = -0-
Depth at Inlet (in) = 3.98
Efficiency (%) = 100
Gutter Spread (ft) = 3.51
Gutter Vel (ft/s) = -0-
Bypass Spread (ft) = -0-
Bypass Depth (in) = -0-
Inlet Report
Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc.Thursday, Nov 17 2016
Catch Basin #3 - Drainage Area 3
Curb Inlet
Location = Sag
Curb Length (ft) = 3.50
Throat Height (in) = 4.50
Grate Area (sqft) = -0-
Grate Width (ft) = -0-
Grate Length (ft) = -0-
Gutter
Slope, Sw (ft/ft) = 0.020
Slope, Sx (ft/ft) = 0.083
Local Depr (in) = 2.00
Gutter Width (ft) = 2.00
Gutter Slope (%) = -0-
Gutter n-value = -0-
Calculations
Compute by: Known Q
Q (cfs) = 1.74
Highlighted
Q Total (cfs) = 1.74
Q Capt (cfs) = 1.74
Q Bypass (cfs) = -0-
Depth at Inlet (in) = 4.70
Efficiency (%) = 100
Gutter Spread (ft) = 4.22
Gutter Vel (ft/s) = -0-
Bypass Spread (ft) = -0-
Bypass Depth (in) = -0-
Inlet Report
Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc.Thursday, Nov 17 2016
Catch Basin #4 - Drainage Area 4
Curb Inlet
Location = Sag
Curb Length (ft) = 3.50
Throat Height (in) = 4.50
Grate Area (sqft) = -0-
Grate Width (ft) = -0-
Grate Length (ft) = -0-
Gutter
Slope, Sw (ft/ft) = 0.020
Slope, Sx (ft/ft) = 0.083
Local Depr (in) = 2.00
Gutter Width (ft) = 2.00
Gutter Slope (%) = -0-
Gutter n-value = -0-
Calculations
Compute by: Known Q
Q (cfs) = 0.99
Highlighted
Q Total (cfs) = 0.99
Q Capt (cfs) = 0.99
Q Bypass (cfs) = -0-
Depth at Inlet (in) = 3.85
Efficiency (%) = 100
Gutter Spread (ft) = 3.38
Gutter Vel (ft/s) = -0-
Bypass Spread (ft) = -0-
Bypass Depth (in) = -0-
HYDRAULIC CALCULATIONS AND
PIPE PROFILES
TR
A
C
T
6
7
6
0
HY
D
R
A
U
L
I
C
C
A
L
C
U
L
A
T
I
O
N
S
(
O
U
T
P
U
T
)
Li
n
e
I
D
L
i
n
e
L
e
n
g
t
h
L
i
n
e
S
i
z
e
F
l
o
w
R
a
t
e
V
e
l
A
v
e
C
a
p
a
c
i
t
y
F
u
l
l
I
nv
e
r
t
D
n
H
G
L
D
n
V
e
l
D
n
V
e
l
H
d
D
n
E
G
L
D
n
S
f
D
n
I
n
v
e
r
t
U
p
(f
t
)
(
i
n
)
(
c
f
s
)
(
f
t
/
s
)
(
c
f
s
)
(
f
t
)
(
f
t
)
(
f
t
/
s
)
(
f
t
)
(
f
t
)
(
%
)
(
f
t)
PI
P
E
1
1
5
9
.
0
1
1
8
3
.
9
2
2
.
2
2
3
.
6
3
3
3
9
.
5
0
3
4
1
.
8
2
2
.
2
2
0
.
0
8
3
4
1
.
9
0
0
.
1
3
9
3
3
9
.
6
9
PI
P
E
2
2
6
1
.
6
3
1
8
2
.
1
8
1
.
2
3
3
.
6
1
3
3
9
.
6
9
3
4
2
.
1
2
1
.
2
3
0
.
0
2
3
4
2
.
1
4
0
.
0
4
3
3
4
0
.
0
0
PI
P
E
3
2
6
.
0
0
1
8
1
.
1
0
2
.
0
9
7
.
4
3
3
4
1
.
4
7
3
4
2
.
2
5
1
.
1
8
0
.
1
4
3
4
2
.
4
0
0.
0
0
0
3
4
1
.
6
0
PI
P
E
4
2
3
.
6
5
1
8
1
.
1
4
2
.
0
6
7
.
4
8
3
4
1
.
3
8
3
4
2
.
2
5
1
.
0
7
0
.
1
5
3
4
2
.
4
0
0.
0
0
0
3
4
1
.
5
0
PI
P
E
5
3
9
4
.
1
1
1
8
2
.
6
0
1
.
4
7
3
.
6
3
3
3
9
.
6
9
3
4
2
.
1
2
1
.
4
7
0
.
0
3
3
4
2
.
1
5
0
.
0
6
1
3
4
0
.
1
6
PI
P
E
6
1
4
.
0
0
1
8
1
.
7
4
0
.
9
8
1
0
.
5
0
3
4
0
.
1
6
3
4
2
.
3
9
0
.
9
8
0
.
0
2
3
4
2
.
4
1
0
.
0
2
7
3
4
0
.
3
0
PI
P
E
7
2
6
.
3
0
1
8
1
.
0
0
0
.
5
7
1
0
.
4
4
3
4
0
.
1
6
3
4
2
.
3
9
0
.
5
7
0
.
0
0
3
4
2
.
4
0
0
.
0
0
9
3
4
0
.
4
2
Li
n
e
I
D
H
G
L
U
p
R
i
m
E
l
e
v
U
p
C
o
v
e
r
U
p
V
e
l
U
p
V
e
l
H
d
U
p
E
G
L
U
p
S
f
U
p
S
fA
v
e
E
n
e
r
g
y
L
o
s
s
J
-
L
o
s
s
C
o
e
f
f
M
i
n
o
r
L
o
s
s
(f
t
)
(
f
t
)
(
f
t
)
(
f
t
/
s
)
(
f
t
)
(
f
t
)
(
%
)
(
%
)
(
f
t
)
(
f
t
)
PI
P
E
1
3
4
2
.
0
4
3
4
7
.
7
6
6
.
5
7
2
.
2
2
0
.
0
8
3
4
2
.
1
2
0
.
1
3
9
0
.
1
3
9
0
.
2
2
2
1
0
.
0
8
PI
P
E
2
3
4
2
.
2
3
3
4
6
.
6
1
5
.
1
1
1
.
2
3
0
.
0
2
3
4
2
.
2
5
0
.
0
4
3
0
.
0
4
3
0
.
1
1
3
1
0
.
0
2
PI
P
E
3
3
4
1
.
9
9
3
4
6
.
1
7
3
.
0
7
3
.
0
1
0
.
1
4
3
4
2
.
1
3
0
.
0
0
0
0
.
0
0
0
0
.
0
0
0
1.
0
0
z
n
/
a
PI
P
E
4
3
4
1
.
9
0
3
4
6
.
0
8
3
.
0
8
3
.
0
6
0
.
1
5
3
4
2
.
0
4
0
.
0
0
0
0
.
0
0
0
0
.
0
0
0
1.
0
0
z
n
/
a
PI
P
E
5
3
4
2
.
3
6
3
4
5
.
9
3
4
.
2
7
1
.
4
7
0
.
0
3
3
4
2
.
3
9
0
.
0
6
1
0
.
0
6
1
0
.
2
4
2
1
0
.
0
3
PI
P
E
6
3
4
2
.
4
0
3
4
5
.
4
6
3
.
6
6
0
.
9
8
0
.
0
2
3
4
2
.
4
1
0
.
0
2
7
0
.
0
2
7
0
.
0
0
4
1
0
.
0
2
PI
P
E
7
3
4
2
.
4
0
3
4
5
.
4
9
3
.
5
7
0
.
5
7
0
.
0
0
3
4
2
.
4
0
.
0
0
9
0
.
0
0
9
0
.
0
0
2
1
0
34
1
.
1
4
34
1
.
0
5
No
t
e
s
:
z
-
Z
e
r
o
J
u
n
c
t
i
o
n
L
o
s
s
PI
P
E
#
1
C
O
N
N
E
C
T
I
O
N
T
O
S
T
U
B
M
H
-
1
PI
P
E
#
2
M
H
-
1
M
H
-
2
PI
P
E
#
3
M
H
-
2
C
B
#
2
PI
P
E
#
4
M
H
-
2
C
B
#
1
PI
P
E
#
5
M
H
-
2
M
H
-
3
M
H
-
3
PI
P
E
#
6
C
B
#
3
M
H
-
3
PI
P
E
#
7
C
B
#
4
DRAINAGE EXHIBITBASIN EXHIBIT
TRACT 6760
BASIN SIZING CALCULATIONS
1.20 344.20
343.00 334.55
8.45 feet
Abtm = 40,882 sq ft = 0.94 acres
Amid = 60,783 sq ft = 1.40 acres
Atop = 73,213 sq ft = 1.68 acres
Existing Sump Capacity =503,097 Cu. FT 11.55 AC-FT
334.55 334.00
0.55 feet
Abtm =32,988 sq ft = 0.76 acres
Amid =33,815 sq ft = 0.78 acres
Atop =40,882 sq ft = 0.94 acres
19,170 Cu. FT 0.44 AC-FT
Existing Sump Capacity =+
Proposed Additional Sump Capacity =
522,268 Cu. FT 11.99 AC-FT
Existing Sump Capacity
TOTAL PROVIDED SUMP CAPACITY =
Proposed Additional Sump Capacity =
TOTAL PROVIDED SUMP CAPACITY =
Bottom Area of Sump
Half Depth Area of Sump
Area of Design Water Level
Prismoidal Formula: Volume = 1/6 x(A btm+4Amid+Atop) x D
Volume = 1/6 x (0.76+3.11+0.94) x 0.55 = 1/6 x (4.81) x 0.55
Exist. Bottom Basin Elev = Prop. Bottom Basin Elev =
Depth from Design Water Surface =
Provided Sump Capacity
Volume = 1/6 x (0.94+5.58+1.68) x 8.45 = 1/6 x (8.20) x 8.45
Depth from Design Water Surface =
Bottom Area of Sump
Half Depth Area of Sump
Area of Design Water Level
Prismoidal Formula: Volume = 1/6 x(A btm+4Amid+Atop) x D
Freeboard (ft)=
Exist. Water Surface Elev =
Exist. Lowest Inlet Elev =
Exist. Bottom Basin Elev =
Proposed Additional Sump Capacity
+
TRACT 6760
BASIN SIZING CALCULATIONS
TABLE OF RUNOFF COEFFICIENTS C x A =
Sq Ft.Acres
R-1, 6000 SF 0.42
R-1, 6750 SF 0.4
R-1, 7500 SF 0.38
R-1, 10000 SF 0.34
R-1, 15000 SF 0.27 30,933 0.71 0.19
R-2 0.55
R-3, R-4, M-H 0.8
Commercial 0.9
Industrial 0.8
Parks 0.15
Pavement, drives & roofs 0.95
Backyards 0.05
Lawn-landscape 2% slope 0.17
Lawn-landscape 2-7% slope 0.22
Lawn-landscape 7% slope 0.35
n C x A =0.19
Total
Total 0.71 =Acres 0.71
Required Sump Capacity = 0.15 x C x A = 0.15 X
n C x A =0.03 AC-FT
=9.04 AC-FT
=2.90 AC-FT
TOTAL 11.97 AC-FT
0.02 AC-FT AC-FTTotal Difference of
Required Sump Capacity
Required Sump Capacity for Tracts 6757 & 6758
Required Sump Capacity for Tracts 6760 & 6491
DRAINAGE EXHIBIT
Know what's
R
REFERNCE
CITY OF BAKERSFIELD RATIONAL METHOD
(In accordance with City of Bakersfield Standards)Street Flow Chart
TABLE OF RUNOFF COEFFICIENTS 60 R/W, Slope=0.200%
R-1, 6000 SF 0.42 Q, cfs V, f/s
JOB TITLE: CURB CAPACITIES TRACT 6491 R-1, 7500 SF 0.38 0.3 1.07 2.6
DATE: Aug-05 R-1, 10000 SF 0.34 0.64 1.35 3
R-1, 15000 SF 0.27 1.6 1.5 4
Rational Values:R-2 0.55 3.75 1.7 5
Event: 10 YEAR Values: 5, 10, 50 R-3, R-4, M-H 0.8 5 1.8 5.5
M.A.P. 6 in./yr. Values: 6, 10, 15, 20, 25, 30 Commercial 0.9 6.5 1.9 6
Industrial 0.8 13 1.9 6
Curve Values Parks 0.15
a: 2.38 I=a+bTc (Tc<20min.) Grasslands, Type A Soil 0.15 Street Flow Chart
b: -0.058 Grasslands, Type B Soil 0.25 60 R/W, Slope=0.250%
P60: 0.550 I=K1*(6.02*Tc)^(0.17*LN(p60/K1) Grasslands, Type C Soil 0.35 Q, cfs V, f/s Curb Cap
K1: 40.00 (Tc>=20min.) Grasslands, Type D Soil 0.45 0.3 1.1 2.5
Pavement, drives & roofs 0.95 0.72 1.5 3
Backyards 0.05 1.8 1.7 4
Lawn-landscape 2% slope 0.10 ` 4.3 1.9 5
Lawn-landscape 2-7% slope 0.15 0.22 5.5 2.02 5.5
Lawn-landscape 7% slope 0.20 0.35 7.3 2.1 6
14.6 2.1 6
SUBAREA C I A rslt Tc L dH Sg Q Street V Trial Tc Roof to Tm Inlet Curb
NAME Runoff Intensity Total Time Length Elev. Gutter Flow Type Vel. MIN. Gutter Travel Size Cap Street Flow Chart
Coef. IN/HR Area Conc. Feet Diff. Slope CFS FPS Time Time Feet In 60 R/W, Slope=0.300%
AC. MIN. Feet Ft/Ft MIN. MIN. Q, cfs V, f/s Curb Cap
0.3 1.25 2.4
RUNOFF & CURB CAPACITY CALCULATIONS 0.79 1.6 3
1.95 1.9 4
AREA 1A 0.90 1.83 0.90 9.47 933 2.333 0.250%1.48 60 1.64 9.47 0 9.47 3.71 4.6 2.05 5
AREA 1B 0.37 1.27 1.91 19.16 383 0.93 0.243%0.90 60 1.53 19.16 15 4.16 3.17 6 2.2 5.5
CP1 0.541 1.27 2.81 19.16 40 0.25 0.625%1.93 60 2.27 19.16 0 0.29 3.62 8 2.35 6
AREA 1C 0.38 1.26 1.56 19.24 383 0.98 0.256%0.74 60 1.50 19.24 15 4.24 3.02 16 2.35 6
CP2 0.483 1.25 4.37 19.45 245 0.65 0.265%2.64 60 1.77 19.45 0 2.31 4.33
AREA 1D 0.41 1.22 1.44 19.90 441 1.14 0.259%0.72 60 1.50 19.90 15 4.90 3.00 Street Flow Chart
CB1 0.464 1.22 5.81 19.90 3.30 19.90 3.5 60 R/W, Slope=0.350%
AREA 2A 0.41 1.10 1.32 23.01 663 1.74 0.262%0.59 60 1.38 23.01 15 8.01 2.85 Q, cfs V, f/s Curb Cap
AREA 2B 0.37 1.26 1.75 19.27 389 1.01 0.260%0.82 60 1.52 19.27 15 4.27 3.09 0.3 1.3 2.25
CB2 0.387 1.10 3.07 23.01 1.31 23.01 3.5 0.85 1.75 3
AREA 3A 0.37 1.15 1.61 21.74 616 1.79 0.291%0.68 60 1.52 21.74 15 6.74 2.96 2.2 2 4
AREA 3B 0.38 1.30 1.25 18.62 321 1.03 0.321%0.62 60 1.48 18.62 15 3.62 2.79 5 2.25 5
CB3 0.374 1.15 2.86 21.74 1.23 21.74 3.5 6.5 2.45 5.5
AREA 4A 0.59 1.00 2.20 26.29 1088 2.72 0.250%1.30 60 1.61 26.29 15 11.29 3.53 8.5 2.5 6
AREA 4B 0.42 1.27 0.90 19.06 369 1.44 0.390%0.48 60 1.52 19.06 15 4.06 2.44 17 2.5 6
CB4 0.541 1.00 3.10 26.29 1.67 26.29 3.5 4.03
AREA 7B/CB7B 0.40 1.34 1.23 17.85 273 0.91 0.333%0.66 60 1.60 17.85 15 2.85 3.5 2.74 Street Flow Chart
AREA 5/CB5 0.42 1.29 8.71 18.80 470 1.508 0.321%4.71 60 2.06 18.80 15 3.80 6.5 5.04 60 R/W, Slope=0.400%
AREA 6/CB6 0.38 1.34 2.19 17.96 369 2.04 0.553%1.11 60 2.08 17.96 15 2.96 3.5 3.07 Q, cfs V, f/s
AREA 7A 0.90 2.03 0.75 6.02 632 1.95 0.309%1.37 60 1.75 6.02 0 6.02 3.50 0.3 1.35 2.2
AREA 7C 0.40 1.28 0.96 18.92 380 1.75 0.461%0.49 60 1.61 18.92 15 3.92 2.73 0.9 1.9 3
CB7 0.619 1.28 1.71 18.92 1.36 18.92 3.5 2.25 2.2 4
AREA 8A 0.90 1.81 1.69 9.79 1044 2.61 0.250%2.76 60 1.78 9.79 0 9.79 4.38 5.3 2.4 5
AREA 8B 0.38 1.26 1.37 19.21 424 1.74 0.410%0.66 60 1.68 19.21 15 4.21 2.68 7 2.55 5.5
CB8 0.667 1.26 3.06 19.21 2.58 19.21 3.5 9.2 2.75 6
AREA 9A 0.90 2.01 0.83 6.32 710 2.49 0.351%1.50 60 1.87 6.32 0 6.32 3.48 18.4 2.75 6
AREA 9B 0.41 1.10 2.03 23.06 789 2.49 0.316%0.91 60 1.63 23.06 15 8.06 3.11
CB9 0.552 1.10 2.86 23.06 1.73 23.06 3.5 Street Flow Chart
AREA 10A 0.90 2.01 0.81 6.36 677 2.02 0.298%1.47 60 1.77 6.36 0 6.36 3.58 60 R/W, Slope=0.500%
AREA 10B 0.38 1.40 1.28 16.86 198 1.34 0.677%0.68 60 1.78 16.86 15 1.86 2.57 Q, cfs V, f/s Curb Cap
CB10 0.582 1.40 2.09 16.86 1.70 16.86 3.5 0.3 1.45 2.05
AREA 11/CB11 0.35 1.38 1.20 17.27 230 1.65 0.717%0.58 60 1.69 17.27 15 2.27 3.5 2.83 1 2.05 3
AREA 12/CB12 0.37 1.41 1.43 16.77 194 1.03 0.531%0.74 60 1.83 16.77 15 1.77 3.5 3.02 2.5 2.4 4
AREA 13/CB13 0.90 2.16 0.96 3.76 385 0.97 0.252%1.87 60 1.71 3.76 0 3.76 3.5 4.03 6 2.7 5
SUMP 0.05 0.83 0.63 33.69 0.03 33.69 0 8 2.9 5.5
10 3 6
TOTAL AREA: 0.47 40.91 20 3 6
2.90 Ac.Ft.Assumptions: Bottom Elev. =
Design Water Surface Elev. =
Hydraulic Grade Line @ Sump =
Future Required Basin Volume = 0.15 x C x A= 0.15 x 0.47 x 40.91 = 2.90 ac-ft
Required Basin Volume = 0.15 x C x A= 0.15 x 0.46 x 30.16 = 2.07 ac-ft
A1= sf
A2= sf
A3= sf
Vol = 1/5*(A1+3*A2+A3)*Depth to DWS
Vol = cf =2.17 ac-ft
Req. Basin Size:333.95
341.95
337.95
94478
11736
16234
RETENTION BASIN DIMENSIONS
7607
05051DS01
McIntosh Associates
2001 Wheelan Ct
Bakersfield, CA 93309 10 yr Calc
CITY OF BAKERSFIELD RATIONAL METHOD TABLE OF RUNOFF COEFFICIENTS
(In accordance with City of Bakersfield Standards)R-1, 6000 SF 0.42
R-1, 7500 SF 0.38
JOB TITLE: DRAINAGE STUDY TRACT 6757 AND 6758 R-1, 10000 SF 0.34
DATE: June 2006 R-1, 15000 SF 0.27
R-2 0.55
Rational Values:R-3, R-4, M-H 0.8
Event: 10 YEAR Values: 5, 10, 50 Commercial 0.9
M.A.P. 6 in./yr. Values: 6, 10, 15, 20, 25, 30 Industrial 0.8
Parks 0.15
Curve Values Grasslands, Type A Soil 0.15
a: 2.38 I=a+bTc (Tc<20min.) Grasslands, Type B Soil 0.25
b: -0.058 Grasslands, Type C Soil 0.35
P60: 0.550 I=K1*(6.02*Tc)^(0.17*LN(p60/K1) Grasslands, Type D Soil 0.45
K1: 40.00 (Tc>=20min.) Pavement, drives & roofs 0.95
Backyards 0.05
Lawn-landscape 2% slope 0.10 0.17
Lawn-landscape 2-7% slope 0.15 0.22
Lawn-landscape 7% slope 0.20 0.35
SUBAREA C I A rslt Tc L dH Sg Q Street V Trial Tc Initial Tm Inlet
NAME Runoff Intensity Total Time Length Elev. Gutter Flow Type Vel. MIN. Time Travel Size
Coef. IN/HR Area Conc. Feet Diff. Slope CFS FPS MIN. Time Feet
AC. MIN. Feet Ft/Ft MIN.
CURB CAPACITY CALCULATIONS
FLOW TO CATCH BASIN #1
AREA 1 0.49 1.16 4.33 21.42 853 3.34 0.392%2.45 60 2.21 21.42 15 6.42 3.50
FLOW TO CATCH BASIN #2
AREA 2 0.36 1.01 7.45 25.91 1272 3.71 0.292%2.71 60 1.94 25.91 15 10.91 3.50
FLOW TO CATCH BASIN #3
AREA 3 0.43 1.23 7.11 19.87 543 1.42 0.262%3.78 60 1.86 19.87 15 4.87 3.50
FLOW TO CATCH BASIN #4
AREA 4 0.42 1.19 3.42 20.69 575 1.49 0.259%1.72 60 1.68 20.69 15 5.69 3.50
FLOW TO CATCH BASIN #5
AREA 5 0.35 1.08 3.39 23.73 840 2.24 0.267%1.28 60 1.60 23.73 15 8.73 3.50
FLOW TO CATCH BASIN #6
AREA 6 0.90 1.80 1.16 10.00 535 1.07 0.200%1.88 90 1.36 10.00 0 6.57 3.50
FLOW TO CATCH BASIN #7
AREA 7 0.33 1.24 1.99 19.59 418 1.12 0.268%0.81 60 1.52 19.59 15 4.59 3.50
FLOW TO CATCH BASIN #8
AREA 8 0.36 1.08 5.30 23.54 977 2.89 0.296%2.06 60 1.91 23.54 15 8.54 3.50
FLOW TO CATCH BASIN #9
AREA 9 0.35 1.14 4.20 21.96 763 2.31 0.303%1.67 60 1.83 21.96 15 6.96 3.50
FLOW TO CATCH BASIN #10
AREA 10 0.34 1.10 4.47 22.95 872 2.66 0.305%1.68 60 1.83 22.95 15 7.95 3.50
FLOW TO CATCH BASIN #11
AREA 11 0.37 1.13 2.92 22.09 678 1.86 0.274%1.22 60 1.59 22.09 15 7.09 3.50
P:\PROJECTS\04102\studies\Drainage\Revisions to Ashe Road Add Street Access (for City Review)\04102DSrevised access steet04102DSrevised access steet
11/18/2015 11:49 AM Page 1
CITY OF BAKERSFIELD RATIONAL METHOD TABLE OF RUNOFF COEFFICIENTS
(In accordance with City of Bakersfield Standards)R-1, 6000 SF 0.42
R-1, 7500 SF 0.38
JOB TITLE: DRAINAGE STUDY TRACT 6757 AND 6758 R-1, 10000 SF 0.34
DATE: June 2006 R-1, 15000 SF 0.27
R-2 0.55
Rational Values:R-3, R-4, M-H 0.8
Event: 10 YEAR Values: 5, 10, 50 Commercial 0.9
M.A.P. 6 in./yr. Values: 6, 10, 15, 20, 25, 30 Industrial 0.8
Parks 0.15
Curve Values Grasslands, Type A Soil 0.15
a: 2.38 I=a+bTc (Tc<20min.) Grasslands, Type B Soil 0.25
b: -0.058 Grasslands, Type C Soil 0.35
P60: 0.550 I=K1*(6.02*Tc)^(0.17*LN(p60/K1) Grasslands, Type D Soil 0.45
K1: 40.00 (Tc>=20min.) Pavement, drives & roofs 0.95
Backyards 0.05
Lawn-landscape 2% slope 0.10 0.17
Lawn-landscape 2-7% slope 0.15 0.22
Lawn-landscape 7% slope 0.20 0.35
SUBAREA C I A rslt Tc L dH Sg Q Street V Trial Tc Initial Tm Inlet
NAME Runoff Intensity Total Time Length Elev. Gutter Flow Type Vel. MIN. Time Travel Size
Coef. IN/HR Area Conc. Feet Diff. Slope CFS FPS MIN. Time Feet
AC. MIN. Feet Ft/Ft MIN.
CURB CAPACITY CALCULATIONS
FLOW TO CATCH BASIN #12
AREA 12 0.35 1.00 7.16 26.36 1198 3.05 0.255%2.53 60 1.76 26.36 15 11.36 3.50
FLOW TO CATCH BASIN #13
AREA 13 0.46 1.29 0.89 18.69 329 1.1 0.334%0.53 60 1.48 18.69 15 3.69 3.50
FLOW TO CATCH BASIN #14
AREA 14 0.32 1.20 2.69 20.41 506 1.38 0.273%1.03 60 1.56 20.41 15 5.41 3.50
FLOW TO CATCH BASIN #15
AREA 15 0.37 1.12 3.71 22.32 725 1.81 0.250%1.53 60 1.65 22.32 15 7.32 3.50
FLOW TO CATCH BASIN #16
AREA 16 0.36 1.21 2.92 20.28 507 1.27 0.250%1.27 60 1.60 20.28 15 5.28 3.50
FLOW TO CATCH BASIN #17
AREA 17 0.35 1.20 2.56 20.50 516 1.42 0.275%1.07 60 1.56 20.50 15 5.50 3.50
FLOW TO CATCH BASIN #18
AREA 18 0.37 1.27 1.56 19.10 407 1.33 0.327%0.73 60 1.65 19.10 15 4.10 3.50
FLOW TO CATCH BASIN #19
AREA 19 0.40 1.20 1.98 20.37 497 1.32 0.266%0.95 60 1.54 20.37 15 5.37 3.50
FLOW TO CATCH BASIN #20
AREA 20 0.40 1.21 1.64 20.25 504 1.49 0.296%0.79 60 1.60 20.25 15 5.25 3.50
FLOW TO CATCH BASIN #21
AREA 21 0.40 1.25 2.71 19.49 539 2.29 0.425%1.35 60 2.00 19.49 15 4.49 3.50
P:\PROJECTS\04102\studies\Drainage\Revisions to Ashe Road Add Street Access (for City Review)\04102DSrevised access steet04102DSrevised access steet
11/18/2015 11:49 AM Page 2
CITY OF BAKERSFIELD RATIONAL METHOD TABLE OF RUNOFF COEFFICIENTS
(In accordance with City of Bakersfield Standards)R-1, 6000 SF 0.42
R-1, 7500 SF 0.38
JOB TITLE: DRAINAGE STUDY TRACT 6757 AND 6758 R-1, 10000 SF 0.34
DATE: June 2006 R-1, 15000 SF 0.27
R-2 0.55
Rational Values:R-3, R-4, M-H 0.8
Event: 10 YEAR Values: 5, 10, 50 Commercial 0.9
M.A.P. 6 in./yr. Values: 6, 10, 15, 20, 25, 30 Industrial 0.8
Parks 0.15
Curve Values Grasslands, Type A Soil 0.15
a: 2.38 I=a+bTc (Tc<20min.) Grasslands, Type B Soil 0.25
b: -0.058 Grasslands, Type C Soil 0.35
P60: 0.550 I=K1*(6.02*Tc)^(0.17*LN(p60/K1) Grasslands, Type D Soil 0.45
K1: 40.00 (Tc>=20min.) Pavement, drives & roofs 0.95
Backyards 0.05
Lawn-landscape 2% slope 0.10 0.17
Lawn-landscape 2-7% slope 0.15 0.22
Lawn-landscape 7% slope 0.20 0.35
SUBAREA C I A rslt Tc L dH Sg Q Street V Trial Tc Initial Tm Inlet
NAME Runoff Intensity Total Time Length Elev. Gutter Flow Type Vel. MIN. Time Travel Size
Coef. IN/HR Area Conc. Feet Diff. Slope CFS FPS MIN. Time Feet
AC. MIN. Feet Ft/Ft MIN.
CURB CAPACITY CALCULATIONS
FLOW TO CATCH BASIN #22
AREA 22 0.62 1.13 4.15 22.20 874 3.97 0.454%2.90 90 2.02 22.20 15 7.20 3.50
FLOW TO CATCH BASIN #23
AREA 23 0.34 1.18 2.78 20.92 560 1.47 0.263%1.13 60 1.58 20.92 15 5.92 3.50
FLOW TO CATCH BASIN #24
AREA 24 0.37 1.09 3.07 23.28 794 2.14 0.270%1.25 60 1.60 23.28 15 8.28 3.50
FLOW TO CATCH BASIN #25
AREA 25 0.49 1.26 2.54 19.29 427 1.16 0.272%1.58 60 1.66 19.29 15 4.29 3.50
FLOW TO CATCH BASIN #26
AREA 26 0.38 1.11 4.66 22.83 893 2.52 0.282%1.96 60 1.90 22.83 15 7.83 3.50
FLOW TO CATCH BASIN #27
AREA 27 0.43 1.37 1.36 17.42 220 0.55 0.250%0.79 60 1.51 17.42 15 2.42 3.50
FLOW TO CATCH BASIN #28
AREA 28 0.42 1.19 2.03 20.75 571 1.6 0.280%1.00 60 1.66 20.75 15 5.75 3.50
FLOW TO CATCH BASIN #29
AREA 29 0.55 1.23 4.67 19.77 563 1.68 0.298%3.16 60 1.97 19.77 15 4.77 3.50
FLOW TO CATCH BASIN #30
AREA 30 0.48 1.38 1.43 17.27 260 1.1 0.423%0.94 60 1.91 17.27 15 2.27 3.50
FLOW TO CATCH BASIN #31
AREA 31 0.38 1.22 2.70 19.95 542 2.01 0.371%1.25 60 1.82 19.95 15 4.95 3.50
FLOW TO CATCH BASIN #32
AREA 32 0.44 1.29 1.45 18.72 386 1.41 0.365%0.83 60 1.73 18.72 15 3.72 3.50
FLOW TO CATCH BASIN #33
AREA 33 0.40 1.31 1.88 18.50 325 0.89 0.274%0.98 60 1.55 18.50 15 3.50 3.50
P:\PROJECTS\04102\studies\Drainage\Revisions to Ashe Road Add Street Access (for City Review)\04102DSrevised access steet04102DSrevised access steet
11/18/2015 11:49 AM Page 3
CITY OF BAKERSFIELD RATIONAL METHOD TABLE OF RUNOFF COEFFICIENTS
(In accordance with City of Bakersfield Standards)R-1, 6000 SF 0.42
R-1, 7500 SF 0.38
JOB TITLE: DRAINAGE STUDY TRACT 6757 AND 6758 R-1, 10000 SF 0.34
DATE: June 2006 R-1, 15000 SF 0.27
R-2 0.55
Rational Values:R-3, R-4, M-H 0.8
Event: 10 YEAR Values: 5, 10, 50 Commercial 0.9
M.A.P. 6 in./yr. Values: 6, 10, 15, 20, 25, 30 Industrial 0.8
Parks 0.15
Curve Values Grasslands, Type A Soil 0.15
a: 2.38 I=a+bTc (Tc<20min.) Grasslands, Type B Soil 0.25
b: -0.058 Grasslands, Type C Soil 0.35
P60: 0.550 I=K1*(6.02*Tc)^(0.17*LN(p60/K1) Grasslands, Type D Soil 0.45
K1: 40.00 (Tc>=20min.) Pavement, drives & roofs 0.95
Backyards 0.05
Lawn-landscape 2% slope 0.10 0.17
Lawn-landscape 2-7% slope 0.15 0.22
Lawn-landscape 7% slope 0.20 0.35
SUBAREA C I A rslt Tc L dH Sg Q Street V Trial Tc Initial Tm Inlet
NAME Runoff Intensity Total Time Length Elev. Gutter Flow Type Vel. MIN. Time Travel Size
Coef. IN/HR Area Conc. Feet Diff. Slope CFS FPS MIN. Time Feet
AC. MIN. Feet Ft/Ft MIN.
CURB CAPACITY CALCULATIONS
FLOW TO CATCH BASIN #34
AREA 34 0.40 1.27 2.22 19.17 488 1.91 0.391%1.12 60 1.95 19.17 15 4.17 3.50
FLOW TO CATCH BASIN #35
AREA 35 0.39 1.26 2.37 19.27 502 2.09 0.416%1.17 60 1.96 19.27 15 4.27 3.50
FLOW TO CATCH BASIN #36
AREA 36 0.36 1.19 4.30 20.60 629 2.01 0.320%1.85 60 1.87 20.60 15 5.60 3.50
FLOW TO CATCH BASIN #37
AREA 37 0.44 1.34 0.99 17.86 236 0.62 0.263%0.59 60 1.37 17.86 15 2.86 3.50
FLOW TO CATCH BASIN #38
AREA 38 0.40 1.35 1.47 17.68 243 0.6 0.247%0.80 60 1.51 17.68 15 2.68 3.50
FLOW TO CATCH BASIN #39
AREA 39 0.45 1.42 0.49 16.58 122 0.39 0.320%0.32 60 1.29 16.58 15 1.58 3.50
FLOW TO CATCH BASIN #40
AREA 40 0.35 1.22 2.55 19.90 493 1.47 0.298%1.09 60 1.68 19.90 15 4.90 3.50
FLOW TO CATCH BASIN #41
AREA 41 0.40 1.34 1.91 17.98 297 0.9 0.303%1.02 60 1.66 17.98 15 2.98 3.50
FLOW TO CATCH BASIN #42
AREA 42 0.38 1.33 1.66 18.13 346 1.49 0.431%0.84 60 1.84 18.13 15 3.13 3.50
FLOW TO CATCH BASIN #43
AREA 43 0.40 1.19 2.42 20.66 613 2.16 0.352%1.15 60 1.81 20.66 15 5.66 3.50
FLOW TO CATCH BASIN #44
AREA 44 A 0.90 1.80 1.25 10.00 783 2.17 0.277%2.03 110 1.36 10.00 0 9.57
AREA 44 B 0.90 1.80 0.84 10.00 420 1.05 0.250%1.36 110 1.27 10.00 0 5.49
Catch Basin #44 0.90 1.80 2.09 3.39 10.00 3.50
P:\PROJECTS\04102\studies\Drainage\Revisions to Ashe Road Add Street Access (for City Review)\04102DSrevised access steet04102DSrevised access steet
11/18/2015 11:49 AM Page 4
CITY OF BAKERSFIELD RATIONAL METHOD TABLE OF RUNOFF COEFFICIENTS
(In accordance with City of Bakersfield Standards)R-1, 6000 SF 0.42
R-1, 7500 SF 0.38
JOB TITLE: DRAINAGE STUDY TRACT 6757 AND 6758 R-1, 10000 SF 0.34
DATE: June 2006 R-1, 15000 SF 0.27
R-2 0.55
Rational Values:R-3, R-4, M-H 0.8
Event: 10 YEAR Values: 5, 10, 50 Commercial 0.9
M.A.P. 6 in./yr. Values: 6, 10, 15, 20, 25, 30 Industrial 0.8
Parks 0.15
Curve Values Grasslands, Type A Soil 0.15
a: 2.38 I=a+bTc (Tc<20min.) Grasslands, Type B Soil 0.25
b: -0.058 Grasslands, Type C Soil 0.35
P60: 0.550 I=K1*(6.02*Tc)^(0.17*LN(p60/K1) Grasslands, Type D Soil 0.45
K1: 40.00 (Tc>=20min.) Pavement, drives & roofs 0.95
Backyards 0.05
Lawn-landscape 2% slope 0.10 0.17
Lawn-landscape 2-7% slope 0.15 0.22
Lawn-landscape 7% slope 0.20 0.35
SUBAREA C I A rslt Tc L dH Sg Q Street V Trial Tc Initial Tm Inlet
NAME Runoff Intensity Total Time Length Elev. Gutter Flow Type Vel. MIN. Time Travel Size
Coef. IN/HR Area Conc. Feet Diff. Slope CFS FPS MIN. Time Feet
AC. MIN. Feet Ft/Ft MIN.
CURB CAPACITY CALCULATIONS
FLOW TO CATCH BASIN #45 (FROM TRACT 6491 DRAINAGE STUDY)
AREA 45 0.90 1.80 0.98 4.84 385 0.97 0.252%1.59 110 1.33 10.00 0 4.84 3.50
FLOW TO CATCH BASIN #45 (FROM THIS STUDY)
AREA 45 0.90 1.80 0.88 9.18 710 2.66 0.375%1.43 110 1.29 10.00 0 9.18 3.50
FLOW TO CATCH BASIN #45 (TOTAL)
AREA 45 0.90 1.80 1.86 8.36 710 2.66 0.375%3.01 110 1.42 10.00 0 8.36 3.50
FLOW TO CATCH BASIN #46
AREA 46 A 0.90 1.80 1.39 10.00 795 2.4 0.302%2.25 110 1.37 10.00 0 9.64
AREA 46 B 0.90 1.80 0.79 10.00 447 1.7 0.380%1.28 110 1.26 10.00 0 5.93
Catch Basin #46 0.90 1.80 2.18 3.53 10.00 3.50
FLOW TO CATCH BASIN #47
AREA 47 A 0.90 1.80 1.32 10.00 796 2.32 0.291%2.14 110 1.37 10.00 0 9.69
AREA 47 B 0.90 1.80 0.70 10.00 470 1.73 0.368%1.13 110 1.22 10.00 0 6.40
Catch Basin #47 0.90 1.80 2.02 10.00 3.27 10.00 3.50
FLOW TO CATCH BASIN #48
AREA 48 0.90 1.80 2.09 7.18 895 3.73 0.417%3.39 110 2.08 10.00 0 7.18 3.50
TOTAL SITE:0.44 136.90
Req. Sump Size:9.04 Ac.Ft. (0.15*C*A)Assumptions:Sump Bottom Elev. = 334.25
+ 2.90 Ac.Ft. (From Tract 6491) Design Water Surface Elev. = 343.00
11.94 Ac.Ft.Hydraulic Grade Line @ Sump =338.63
A1= sf
A2= sf
A3= sf
Vol = 1/5*(A1+3*A2+A3)*Depth to DWS
Vol = cf =12.16 ac-ft529664
SUMP DIMENSIONS
48167
60433
73199
P:\PROJECTS\04102\studies\Drainage\Revisions to Ashe Road Add Street Access (for City Review)\04102DSrevised access steet04102DSrevised access steet
11/18/2015 3:40 PM Page 5