HomeMy WebLinkAboutUST REP. 11/23/2015BAKERSFIELD FIRE DEPARTMENT
Prevention Services Division
Underground Storage Tank Program 2101 H Street
DW Inspection Report Bakersfield, CA 93301
Permission to Inspect: Phone: 661- 326 -3979
Fax: 661 -852 -2171
Business Name: Arco AMPM (Monterey), 15- 021 - 102327
Date: 11/23/15
Address Name: 900 Monterey, Bakersfield,CA93305, (661) 861 -1972
Inspector Name: Kris Karns (8292402)
Inspection Type: Routine
Report :Final
NVO = No Violation Observed OUT = Out of Compliance NA = Not Applicable UD = Undetermined
COS = Corrected On Site RPT = Repeat Violation
Violation
Program Requirement
o
SOC
Comments
No
a
o
o
a
�o
Z
O
Z
U
�?
File Review
Facility Tank Information
2030021
Facility has a valid Permit
Tank 1- 12000 -REG #1 -DW
to Operate from the
Tank 2- 12000 -REG #2 -DW
CUPA - 23 CCR 16 2712(1);
®
❑
❑
❑
❑
❑
None
Tank 3- 12000 - SUP -DW
HSC 6.7 25284
2010010
UST Operating Permit
Application for Facility
information and Tank
information
®
❑
❑
❑
❑
❑
None
submitted /maintained - 23
CCR 16 2711; HSC 6.7
25286(a)
2010001
Current BOE number
submitted to the CUPA
®
❑
❑
❑
❑
❑
None
and /or CERS - HSC 6.7
25286(c)
2030011
UST compliance
statement and /or
Designated Operator
®
❑
❑
❑
❑
Ej
None
current certification
submitted - 23 CCR 16
2715(a), 2715(b
2030046
A complete and accurate
response plan has been
submitted, approved and
®
❑
❑
❑
❑
❑
None
maintained - 23 CCR 16
2632, 2634(e), 2641(h),
2712(i)
2030041
A complete and accurate
plot plan has been
submitted, approved and
❑
❑
❑
❑
None
maintained - 23 CCR 16
2632(d) 1 C , 2711(a)(8
2010006
Owner /Operator has not
made false statements or
representation on any
®
❑
❑
❑
❑
❑
None
required document - HSC
6.7 25299
Underground Storage Tank Program
DW Inspection Report
Permission to Inspect:
[_Business Name: Arco AMPM (Monterey), 15-021-102327
Date: 11/23/15
Address Name: 900 Monterey, Bakersfield, CA93305, (661) 861-1972
Inspector Name: Kris Karns (8292402)
Inspection Type: Routine
Report: Final
NVO = No Violation Observed OUT = Out of Compliance NA = Not Applicable UD = Undetermined
COS = Corrected On Site RPT = Repeat Violation
Violation
Program Requirement
0
SOC
Comments
No
9.cc
n
In
0
0.
z
0
z
I
:)
I
(.)
W
>
File Review
Facility Tank Information
2030021
Facility has a valid Permit
Tank 1-1 2000-REG #1 -DW
to Operate from the
Tank 2-12000-REG #2 -DW
CUPA - 23 CCR 16 2712(1);
F-1
❑
❑
❑
❑
None
Tank 3-12000-SUP-DW
HSC 6.7 25284
2010010
UST Operating Permit
Application for Facility
information and Tank
information
❑
❑
❑
❑
None
submitted/maintained - 23
CCR 16 2711; HSC 6.7
25286(a)
2010001
Current BOE number
submitted to the CUPA
❑
❑
❑
None
and/or CERS - HSC 6.7
25286(c)
2030011
UST compliance
statement and/or
Designated Operator
F-1
❑
❑
None
current certification
submitted - 23 CCR 16
2715(a), 2715(b)
2030046
A complete and accurate
response plan has been
submitted, approved and
❑
❑
1:1
E-1
❑
None
maintained - 23 CCR 16
2632, 2634(e), 2641(h),
2712
2030041
A complete and accurate
plot plan has been
submitted, approved and
❑
RE]
❑
❑
None
maintained - 23 CCR 16
2632(d)(1 (C), 2711(a)(8)
2010006
Owner/Operator has not
made false statements or
representation on any
None
required document - HSC
6.725299
Violation
Program Requirement
m o
SOC
Comments
No
<t
o
o
a
ai o
z
O
z
2010003
Owner /Operator has a
DO and /or informed the
CUPA of any change (s)
®
❑
❑
❑
❑
❑
None
within 30 days - 23 CCR
16 2715(a)
Testing
2030002
Owner /Operator has
tested and certified leak
®
❑
❑
❑
❑
❑
None
detection equipment
annual) - 23 CCR 16 2638
2030048
Secondary containment
Failure to perform secondary
testing conducted every
containment testing within the
36 months in accordance
❑
®
❑
❑
❑
❑
None
rquired 36 months.
with requirements - 23
CCR 16 2637
2030055
Spill buckets have been
tested annually as
®
❑
❑
❑
❑
❑
None
required - HSC 6.7 25284.2
2010009
Secondary containment
test results submitted to
the CUPA within 30 days
®
❑
❑
❑
❑
❑
None
after the test - 23 CCR 16
2637(e)
2030064
CUPA was poperly
notified within the
prescribed number of
®
❑
❑
❑
❑
❑
None
hours prior to testing - 23
CCR 16 26370, 2638(e),
2643(g), 2644.1(a)(4)
Install /Repair
2060009
Permits obtained to
install, replace, repair, or
®
❑
❑
❑
❑
❑
None
modify part of the UST
system - 23 CCR 16 2712
UST System Observation
General Monitoring
2030003
Leak detection system
maintains continuous
RD
monitoring that activates
®
❑
❑
❑
❑
❑
None
❑
an audible and visual
Yes
alarm - 23 CCR 16 2632,
2634, 2636,. 2666
2030016
The annular space of the
L -7 Tank #3 (91) 409 Annular
tank, piping and sumps
Sensor would not activate when
are continuously
RD
tested. Anew sensor was
monitored and activates
❑
®
❑
❑
❑
❑
None
®
installed, re- tested and confirmed
the alarm - 23 CCR 16
Yes
operational. Violation was
corrected on site.
2631(g), 2632(c)(2)(A) &(B),
2633(c), 2636
2030017
Product piping outside the
UDC is fail -safe and shuts
down the pump or
®
❑
❑
❑
❑
❑
None
restricts flow - 23 CCR 16
26360 (5)
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
m o
SOC
Comments
No
q
o
O
a
ac
z
o
z
2030018
Turbine sump monitor
activates an audible and
RD
visual alarm or stops the
®
❑
❑
❑
❑
❑
None
❑
flow of at the dispenser -
Yes
23 CCR 16 2636(0(1)
2030019
Monitoring system in the
UDCs activates an
audible and visual alarm
®
❑
❑
❑
❑
❑
None
or stops the flow at the
UDC -23 CCR 16
2636 (0(1)
2030043
Leak detection equipment
properly programmed or
RD
properly operated - 23
®
❑
❑
❑
❑
❑
None
❑
CCR 16 2632, 2634, 2636,
Yes
2666
2060005
System constructed with
a monitoring system
capable of detecting entry
®
❑
❑
❑
❑
❑
None
into secondary
containment - HSC 6.7
25291(b)
2060014
Correct leak detection
equipment installed for
RD
the type of system
❑
❑
❑
❑
❑
None
❑
present - 23 CCR 16 2638;
Yes
HSC 6.7 25290.1, 25290.2,
25291
2060015
Sensor located in the
RD
proper position /location -
❑
[]
❑
❑
❑
None
❑
23 CCR 16 2630(d), 2641(a)
Yes
2030062
Facility is in compliance
with not tampering with or
RD
disabling leak detection
®
❑
❑
❑
❑
❑
None
❑
devices or alarms - HSC
Yes
6.7 25299(x)(9)
2060022
System constructed with
a monitoring system
capable of detecting entry
®
❑
❑
❑
❑
❑
None
into secondary
containment - HSC 6.7
25290.2(d)
2030034
Tag /sticker on affixed
monitoring equipment
being certified, repaired,
®
❑
❑
❑
❑
❑
None
or replaced - 23 CCR 16
2638(1)
VPH Monitoring VPH
2030065
Interstitial monitoring of
the annular spaces of the
RD
UST is properly
❑
❑
®
❑
❑
❑
None
❑
maintained - HSC 6.7
Yes
25290.1(e
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
0 0.0
SOC
Comments
No
:0:1.
Q
a
0
0.
0
Z
0
Z
05
2060023
System constructed with
a monitoring system
capable of detecting entry
into secondary
0
❑
❑
❑
None
containment - HSC 6.7
25290.1(d)
Line Leak
Detector
2060012
Line leak detector
installed on pressurized
RD
piping system - HSC 6.7
0
❑
None
❑
25290. 1 (h), 25290.2(8),
Yes
252910, 25292(e),
2636(0(2)
2030026
Line leak detectors detect
a 3 gph leak and/or
RD
audible and visual alarm
S
❑
❑
None
❑
function properly - 23
Yes
CCR 16 2636(0(6),
2666(c)
2030027
Turbine shuts down when
a leak is detected or
RD
when line leak detector is
None
❑
disconnected - 23 CCR 16
Yes
2666(c)
2030025
Pressurized piping able to
detect a 3.0 gph leak
RD
within an hour, and
None
❑
restricts the flow or
Yes
alarms - 23 CCR 16
2636 2)
Secondary Containment
2060010
UST storing a hazardous
RD
substance has secondary
None
[:1
containment - HSC 6.7
Yes
25292
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
4-
0
SOC
Comments
No
0>
D
<
0
0
00
Z
0
Z
D
0
W
05
0
2030008
UDC, sumps, and/or
other secondary
containment in good
0
1:1
❑
None
condition and/or are free
of debris/liquid - HSC 6.7
25290.1, 25290.2, 25291
2030040
Secondarily contained
RD
piping maintained to allow
Z
❑
❑
❑
❑
❑
None
❑
liquid to drain into sump -
Yes
23 CCR 16 2630(d), 2641(a)
2060006
Secondary containment
piping slopes back to the
None
collection sump - 23 CCR
6 263(c)
2030047
Secondary containment
maintained tight and has
been confirmed by testing
None
m 23 CCR 16 2662, HSC 6.7
25290.1(c)(2), 25290.2(c)(2),
25291(a), 25292(e)
2030060
Entry fittings in secondary
containment for UST
system maintained
2
❑
1:1
❑
❑
❑
None
tight/sealed - 23 CCR 16
2630, 2635(d), 2636(c),
2666
2060020
Spill bucket is installed
RP
and has a functional drain
valve or other means to
❑
None
❑
remove liquid - 23 CCR 16
Yes
2635(b), 2665
2030054
Spill bucket maintained in
RP
good condition and free of
Z
❑
❑
❑
❑
❑
None
❑
debris and/or liquid - 23
Yes
CCR 16 2635(b), 2715(c)(2)
2060019
Spill bucket to has a
minimum capacity of five
None
gallons m 23 CCR 16
2635(b), 2665
Overfill
2030035
UST system is operated
to prevent unauthorized
RP
release, including spills
None
❑
and overfills - HSC 6.7
Yes
25292.1 (a)
2030036
Overfill prevention system
RP
has not been overridden
and meets overfill
None
❑
requirements - 23 CCR 16
Yes
2635(b)(2), 2665
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
° o
SOC
Comments
No
�C
o
O
a
o
Z
O
Z
C)
W
On Site
Records
Certifications
2030023
Required designated
operators or contractors
maintain a proper and
❑
❑
❑
❑
❑
None
current ICC certification -
23 CCR 16 2715
2030024
Service technician,
installer, and/ or
employee maintain a
®
❑
❑
❑
❑
❑
None
proper license - 23 CCR
162715
2030031
Employee or contractor
obtained and maintained
proper manufacturer
®
❑
❑
❑
❑
❑
None
certification - 23 CCR 16
2715
2010007
Submit/maintain current
Certificate of Financial
Responsibility /mechanism
of financial assurance -
®
❑
❑
❑
❑
❑
None
23 CCR 16 2711; 23 CCR
18 2808.1, 2809- 2809.2;
HSC 6.7 25292.2; HSC
6.75 25299.30- 25299.34
Designated Operator
2010004
Copies of DO inspections
Failure to maintain on site
for last 12 months and list
designated operator reports for the
of trained employees
❑
®
❑
❑
❑
❑
None
last 12 months.
maintained - 23 CCR 16
2715
2030013
Designated operator
properly conducted the
monthly inspection and
®
❑
❑
❑
❑
❑
None
the reports are complete -
23 CCR 16 2715
2030010
DO notified operator of
any condition observed
during the monthly
®
❑
❑
❑
❑
❑
None
inspection that may
require action - 23 CCR 16
2715(d
2030012
DO employee training
Failure to have at least one
performed, current for at
employee on site who has been
least one employee on
❑
®
❑
❑
❑
❑
None
trained by the designated operator
site, and a log kept - 23
within the last 12 months.
CCR 16 2715(c)(6), 27150
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
4-
0
0.0
SOC
Comments
No
>0
d
a
0
(L
Q)0
Z
0
Z
:D
>
Logs
2030001
Leak detection alarm
logs, maintenance and
RD
records of appropriate
❑
n
❑
❑
None
❑
follow-up actions
Yes
maintained - 23 CCR 16
2632, 2634, 2712(b)
Maintenance/Tests
2010008
Monitoring, maintenance,
Failure to maintain on site fuel
repairs, linings, and
RD
monitoring certification and sb-989
upgrade records
None
0
records on site for the required
maintained for the proper
Yes
time.
time period - 23 CCR 16
2712(b)
Documentation
2030033
Failure to maintain on site
an approved monitoring
❑
1:1
❑
❑
None
plan - 23 CCR 16 2632,
2634, 2711, 2712(1)
2030037
Written agreement
between the tank owner
and tank operator to
monitor the tank system
0
❑
1:1
❑
❑
❑
None
is maintained - 23 CCR 16
2620(b); HSC 6.7
25284(a)(3)
2030061
Suspected or actual
unauthorized release
RD
reported in appropriate
None
❑
time frame - HSC 6.7
Yes
29294,29295
General Operating Requirements
Permit Condition/Approval
2030039
Compliance with all
operating permit
None
conditions - 23 CCR 16
2712, HSC 6.7 25299
2030059
UST system maintained
in accordance with
exclusion/exemption
❑
❑
None
status - HSC 6.7 25281.6,
25283.5
2030014
Owner/Operator received
approval and has
implemented a training
None
program at an unstaffed
facility - 23 CCR 16
2715 (2)
2030015
Facility exhibited that the
method used to monitor
the tank meets the
monitoring methods in
None
2643(f - 23 CCR 16 2643
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
4-
0 .2
o
S-- 0C
Comments
No
a
CO
0
a.
42
Qo
z
0
z
n
0
W
Red Tag
2030045
Red Tag information is
legible and has not been
Z
None
tampered with - 23 CCR
16 2717.1(g)
2030044
Facility did not allow for
deposit of petroleum into
a UST that has a red tag
None
affixed to the fi ll - 23 CCR
162717.1(0
Install/Repair
2060024
UST system is made of or
lined with materials that
are compatible with the
None
substance stored - 23
CCR 16 2631.1
2060021
Striker plate installed and
positioned correctly - 23
❑
1:1
1:1
Z
❑
❑
None
CCR 16 2631(c), 2662(4 )
I
❑ There were no violations noted for this inspection.
ZThis report shall serve as a "NOTICE TO COMPLY" for Minor Violations, and a "NOTICE OF VIOLATION" for
Major violations. You are, hereby, ordered to correct the above noted violations within 30 days, or according to
correction summaries provided. Formal enforcement and/or penalty assessment may be initiated for any
violations noted, and for those not corrected in a timely manner. (NOTE: If this is a preliminary report, a final report
will follow.)
Inspectors Signature: et�-� Date: i L "d3 a�
Inspector: Enter # of Violations: RD: a RP: Q
Check one box for facility Significant Operational Status (SOC) to be reported to SWRCB and US EPA:
❑ SOC with both Release Detection and Release Detection (Facility has no Release Prevention and no Release
Prevention Violations)
❑ Not in SOC (Facility has both Release Prevention and Release Detection Violations)
❑SOC with Release Detection only (Facility has no Release Detection violations but one or more Release Prevention
violations)
0 SOC with Release Prevention only (Facility has no Release Prevention violations but one or more Release Detection
violations)
Underground Storage Tank Program - DW Inspection Report v 2.0