HomeMy WebLinkAboutHAZ WASTE 1/27/20171.
= % - V1111J10.11.1L.
Y — t.luJJ 1, u Vl ♦.uaava
HAZARDOUS WASTE REQUIREMENT
N/A
C S
Violation #
COMMENTS
C .
V'
Recordkee in documentation
Generator has an EPA ID number [HSC 25143:131
3010002
Hazardous waste determination made for. all wastes
B59enerator Knowledge [CCR 66262.40]
3030005
Contingency plan information posted near phone [CCR 66262.34(d)(2)]
3010022
'
Facility personnel demonstrate trainin /awareness .[CCR 66262.34(d)(2)]
3020001
Manifests /Consolidated Manifest receipts complete [CCR 66262:23(a)]
3010008
Blue copy(s) of manifest mailed -to DTSC [CCR 66262.23(a)(4)]
3010011
Bills of Lading/receipts available [CCR 66262.40(a)]
3010010
LDRs- available and complete [C.CR 66268.7(a)] '.
3030006
Onsite recycling reported using UPCF [HSC 25143.10] .
3030001
Container /tank'.mana ement
)0
Containers are in good condition . [CCR 66262.34(d)(2)].
Containers are closed except when adding /removin [CCR66262.34(d)(2)]
3030013.
3030017
1-:. C',, i ;'a� -= q
Satellite containers at or near point of generation [CCR 66262.34(e)(1)(A)]
Empty containers are empty [CCR 66262.34(f)].
3030007,
'
Containers ins ected weekly [CCR 66262.34(d)(2)]
3030019
Tanks inspected daily [CCR 66262.34(d)(2), 40CFR 265.201]
3030027
One container per waste stream at satellite area [CCR 66262.34(d)(2)] .
Exclude recyclable materials stored in accordance with local
ordinance/hazardous materials codes [HSC 25143.10]'
3030022
3010016
Accumulation Time Limits
Waste is accumulated not more than 90 /180/270 [CCR. 66262.34(d)]
3030010
'Empty containers ,managed within one year [CCR.66262:34(d)]
3030010
Universal waste accumulated less than one year [CCR 66273.15(a)]
3030011
Used oil filters offsite within :180 (1 year <1 ton) [CCR 66266.130(c)(4)]
3030004.
Pb,acid batteries offsitewithin 180 (1 yr. < 1 ton) [CCR60266.81(a)(3)]
12>4
1 3030002'
Labeling/Marking
Containers are properly labeled [66262.34(f)]
3030007
-`
Excluded recyclable materials marked properly [HSC 25143.9(a)]•
3050005
Universal waste container propetlylabeled (CCR 66273.341
3030008
Used oil filters marked "drained used oil filters" [CCR 66266.1301
a ,
3030004
Date'written on spent lead -acid batteries [CCR 66266.81(a)(6)(B)]
3030003
Used Oil" marked' on all used oil tanks /containers [CCR 66279.21(b)]
3030007
Tank marked with "haz'waste" , contents, start date [66262.34(f)]
3030007
Treatment, Transport and Disposal/Other
Have permit/authorization to do treatment [HSC 25136.21
30
3040003.
Waste sent with authorized transport (men. eli ible) [CCR 66263.41]
3050001.
Waste disposed of to. authorized point/ party [HSC 25189.5(a)]
;
3050002
`Failed to handle appliance w=astes [HSC 25212(a)]
prop
Fire Protection [6626234(d)(2)]
3030.032
Print and sign in this box for receipt of this report. Signature does not imply agreeinent with findings only receipt of report..
INSPECTOR
IN
POST INSPECTION INSTRUCTIONS:
• Correct. the violation(s) noted. above by
natur'(that all violations have been corrected as noted).
• Within 5 days of correcting allof the violations, sign and return a copy of this page to:
Bakersfield Fire Dept., Prevention Services, 2101 H St: Bakersfield; CA 93301 Date
i FD2171 (Rev 9/14) ,