HomeMy WebLinkAbout2016 INSPECTION REPORTUnderground Storage Tank Prou
DW Inspection Report
Permission to Inspect:
BAKERSFIELD FIRE DEPARTMENT
Prevention Services Division
2101 H Street
Bakersfield, CA 93301
Phone: 661-326-3979
Fax- 661-852-2171
Business Name: Xpress Gas-NIKAKHTAR AHMAD-1 5-021-103872
Date:12/14/2016
Address Name: 402 S Chester
Inspector Name: Shane Gardner #8248557
Inspection Type: Routine LI
Report : Final
NVO = No Violation Observed OUT = Out of Compliance NA = Not Applicable UD = Undetermined
COS = Corrected On Site RPT = Repeat Violation
Violation
Program Requirement
0 ro-
0.-
SOC
Comments
No
0
0,4.,
cc
I- o
V)
z
0
z
D
0
W
File Review
Facility Tank Information
2030021
Facility has a valid Permit
Tank 1-12000-DW-REG
to Operate from the
Tank 2-8000-DW-PRM
CUPA - 23 CCR 16 2712(1);
❑
❑
❑
❑
None
Tank 3-
HSC 6.7 25284
Tank 4-
2010010
UST Operating Permit
Owner has just taken over site
Application for Facility
will have 30 days to update cers
information and Tank
before a violation will be issued
information
1:1
❑
❑
None
submitted/maintained - 23
CCR 16 2711; HSC 6.7
25286(a)
2010001
Current BOE number
submitted to the CUPA
❑
❑
❑
❑
❑
None
and/or CERS - HSC 6.7
25286(c)
2030011
UST compliance
statement and/or
Designated Operator
None
current certification
submitted - 23 CCR 16
2715(a), 2715(b)
2030046
A complete and accurate
response plan has been
submitted, approved and
None
maintained - 23 CCR 16
2632, 2634(e), 2641(h),
2712(i)
2030041
A complete and accurate
plot plan has been
submitted, approved and
Minor
maintained - 23 CCR 16
2632(d)(1)(C), 2711(a)(8)
2010006
Owner/Operator has not
made false statements or
representation on any
None
required document - HSC
6.725299
2010003
Owner/Operator has a
DO and/or informed the
CUPA of any change (s)
[--J
❑
None
within 30 days - 23 CCR
16 2715(a)
Violation
Program Requirement
4-
C
0 0 .0
SOC
Comments
No
O
0
0
0.
0Oo 0
1
z
0
z
:3
Testing
2030002
Owner/Operator has
tested and certified leak
E
El
❑
❑
❑
❑
None
detection equipment
annually - 23 CCR 16 2638
2030048
Secondary containment
testing conducted every
36 months in accordance
None
with requirements - 23
CCR 16 2637
2030055
Spill buckets have been
tested annually as
None
required - HSC 6.7 25284.2
2010009
Secondary containment
test results submitted to
the CUPA within 30 days
None
after the test - 23 CCR 16
2637(e)
2030064
CUPA was poperly
notified within the
prescribed number of
❑
❑
❑
None
hours prior to testing - 23
CCR 16 26370, 2638(e),
2643(8), 2644.1(a)(4)
Install/Repair
2060009
Permits obtained to
install, replace, repair, or
❑
❑
❑
❑
None
modify part of the UST
system - 23 CCR 16 2712
UST System Observation
General Monitoring
2030003
Leak detection system
maintains continuous
RD
monitoring that activates
E
❑
❑
None
❑
an audible and visual
Yes
alarm - 23 CCR 16 2632,
2634, 2636, 2666
2030016
The annular space of the
tank, piping and sumps
RD
are continuously
monitored and activates
®
❑
❑
❑
None
the alarm - 23 CCR 16
Yes
2631(8), 2632(c) (2) (A) &(B),
2633(c), 2636(o
2030017
Product piping outside the
UDC is fail-safe and shuts
down the pump or
❑
❑
❑
None
restricts flow - 23 CCR 16
2636(0 (5)
2030018
Turbine sump monitor
RD
activates an audible and
visual alarm or stops the
E
❑
❑
None
❑
flow of at the dispenser -
Yes
23 CCR 16 26360(1)
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
m o
SOC
Comments
No
M
Q
o
O
a
00
z
O
z
M
V
W
�j
2030019
Monitoring system in the
UDCs activates an
audible and visual alarm
®
❑
❑
❑
❑
❑
None
or stops the flow at the
UDC -23 CCR 16
2636 (0(1)
2030043
Leak detection equipment
RD
properly programmed or
properly operated - 23
®
❑
❑
❑
❑
❑
None
❑
CCR 16 2632, 2634, 2636,
Yes
2666
2060005
System constructed with
a monitoring system
capable of detecting entry
®
❑
❑
❑
❑
❑
None
into secondary
containment - HSC 6.7
25291(b
2060014
Correct leak detection
equipment installed for
RD
the type of system
®
❑
❑
❑
❑
❑
None
❑
present - 23 CCR 16 2638,
Yes
HSC 6.7 25290.1, 25290.2,
25291
2060015
Sensor located in the
RD
proper position /location -
0
❑
❑
❑
❑
❑
None
❑
23 CCR 16 2630(d), 2641(a)
Yes
2030062
Facility is in compliance
RD
with not tampering with or
disabling leak detection
®
❑
❑
❑
❑
❑
None
❑
devices or alarms - HSC
Yes
6.7 25299(a )(9
2060022
System constructed with
a monitoring system
capable of detecting entry
®
❑
❑
❑
❑
❑
None
into secondary
containment - HSC 6.7
25290.2(d)
2030034
Tag /sticker on affixed
monitoring equipment
being certified, repaired,
®
❑
❑
❑
❑
❑
None
or replaced - 23 CCR 16
2638
VPH Monitoring VPH
2030065
Interstitial monitoring of
RD
the annular spaces of the
UST is properly
❑
❑
®
❑
❑
❑
None
❑
maintained - HSC 6.7
Yes
25290.1(e)
2060023
System constructed with
a monitoring system
capable of detecting entry
into secondary
❑
❑
®
❑
❑
❑
None
containment - HSC 6.7
25290.1(d)
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
4-
0
0.0
SOC
Comments
No
C)
0
M
42
030
Z
0
Z
Ir
05
Line Leak
Detector
2060012
Line leak detector
installed on pressurized
RD
piping system - HSC 6.7
None
❑
25290. 1 (h), 25290.2(g),
Yes
252910, 25292(e),
2636(0(2)
2030026
Line leak detectors detect
a 3 gph leak and/or
RD
audible and visual alarm
None
❑
function properly - 23
Yes
CCR 16 2636(0(6),
2666(c)
2030027
Turbine shuts down when
a leak is detected or
RD
when line leak detector is
None
❑
disconnected - 23 CCR 16
Yes
2666(c)
2030025
Pressurized piping able to
detect a 3.0 gph leak
RD
within an hour, and
None
❑
restricts the flow or
Yes
alarms - 23 CCR 16
2636(t) (2)
Secondary Containment
2060010
UST storing a hazardous
RD
substance has secondary
Z
❑
None
❑
containment - HSC 6.7
Yes
25292