Loading...
HomeMy WebLinkAbout1.8-6853 Ph 2CAUTION JOINT TRENCH WITH POWER &Ut WORK SAFELY! mat : t SB 2201 r 01 I I1 12 13 14 i 5 1 6 1 7 1 8 1 9 110 1 11 (12 113 114 I15 1161 17 118 I 19 � � SB31I f I S112 II I I I SB13 I I I I S814 I I Fit HH-17X30XJ4 (PPA) 8#5C HH-17X3��pC24 (PPA) S�tSC I HH-17X�0X24 (PPA)I845C I IHH-17X30�(24 (PPA) 84PC ISSUE1 DATE 1 106/15/151 GEN. SAFETY NOTES: CAUTION: CONSTRUCTION ZONE HARD HAT AREA. CAUTION: HIGH TRAFFIC AREA 46 LABOR NOTES: "x;�'°"z4 17X30XZ 1/x3loxza � � I ^,G^C"� � - PLACE 1.25 INNERDUCT BETWEEN 17x30 5610 � � SPLICE BOXES. 17x3 x24 _ � _ _ � _ _ _ � _ — � — — � — — � — — —� — — — —� — — - PLACE 1' INNERDUCT TO EACH HOUSE — .� FROM SPLICE BOXES. LEAVE 40' COIL _ __ _ _ _ . _ _ _ _ _ RIBSTON. AVE, _ _ _ . _ _ 240' IPP -1 1/4 - PP -1 1/4 -U -OR (PPA) P-1 1/4 -U -OR (PPA) 8 OF 1' INNEREDUCT AT EACH LOT LINE. e-------------------------------------------------------------------------- �---------- --� ----- - -PLACE 2- 1.25' INNERDUCT FROM S62201 - - --------------------- GRD BED — � RIBSTON AVE � � � � � � � TO SB15. -PLACE EXISTING INNERDUCT FROM SB7 CL 1-----r----�— —�— 7—T �— -- -- —� „ TO NEW SB17. FUSE 1-4' STUB FROM EXISTING SB10 TO I I I I i I i 7,f� I I I I I PLACE 1' INNERDUCT TO LOTS 1& 2, o 3 36 1 35 1 34 (33 1 32 1 31 1 30 1— j— --I-- — —�-' — --I— — —r– — —�-- �--- 2_��—--�—----—I �� � } 128 12� � Zs � 25 � Za 123 I 22 121 ( Zg -, o w 7 � —�5 46 47 a oCC a 0 I I I I I I I SB17 I ( I I I HSB H -17X3044 (PPA)844C I I I S815 to 17X30X2�X24 (PPA)8r5C I I 17X30X24 HH -30X48 36 (PA)I W I I I I I I 30X48X3 I I \1z �1 C,B7 120' P -i i/4 -U -OR t 01 � 240' I -1 1/4 -U -OR (PPA) 845C 300' IPP -1 1/4 -U -OR IPPA) 845C •----------•---••--WOLF. RIVER. .AYE ---- ----17X30X24 � -- 263•t -Pc -4-c (PPA)4C --•--••-•-----•-•-•-------•---•---•-------•----•--•--- -----••----•--•----•---••--•---•---•-WOLF- RIMER- -AVE -----------•----------r-------------------------------- GRD BE PL EM � 3 TIE IN FOR FUTURE PHASE 845C o HH-17X30X24 6 EXEMPT MATERIAL ONLY I I I 49( 50 I 51 I 52 I 531 54 I cn' v /--g\845C � �6 PLACE HANDHOLE -NEW �.�.. CONST. ARC DATE COMP. 9,478 Place Item in Trench HH-30X48X36 1 EXEMPT MATERIAL ONLY ^845C / �1 PLACE HANDHOLE -NEW 5 845C IPP -1 1/4 -U -OR 2765 MATERIAL ONLY COPPE 6 8645C IPP -I -U -BL 3225 EXEMPT MATERIAL ONLY �-7 18645C [— IPP -I -U -BL 3225 EXEMPT MATERIAL ONLY 8 4C 1 -PC -4-C 263 MATERIAL ONLY AT&T lg 845C 2 PLACE GROUND FIELD f -1-1\845C 2000 LUMP SUM MATERIAL CO 12 8645C 3500 LUMP SUM MATERIAL CO 111"il"in"i'',"No Tma-f aw� DIAGRAM FOR CONNECTIONS O GROUND RODS BARE a T NTINVOUS -- fft' NO ORD WIRE 8 SOUD- wgW—E RD ROD AWO) Vv AT&T �yC�7TIICE Iy/y I r MiNUUM COVER TO TOP OF RODS riniviiIr f 1 LIN m .W GROLND RODS 1 E EVERY iii NILE 8-6, 9.5-3 Na- GEO/Co SA -27 EXCH BAKERSFIELD WEST ENGT BRAIN F RANZ TEL: 661- ENG'R ARC VOKDEODOO TYPE OF CONST. FTTP SUBDIVISION TRACT 6853 PHASE 2 RO/EST No. A005TGW 1-349 DWG 3 OF 7 P-504 0 Proprietary (Internal Use Only).Not for use or disclosure outside the AT&T companies except under written c-�igreemento NCL Io Electric Design by: _ L P E S it UTILITY DESIGN S�R�rIc�� Office (559) 641 2954 46325 Wath lane Celt (SS9) 760 9464 Ahwahnee. Cattfvrrtta 93+6fl1 CTRIC C TRUCTIO � E'CH TIZACT 6853 PHASE 2 RI TON AVE EL TORO I EJ O D Bt �CERS iEL�i CA►UFf� N1A Ana- - 6a � � - Pm feet Management by: Callforr,.a Utility Consultants Inc 7591 r� b� Ave. Suife 103 Fresno, CA 93711 Phone (559)-261-9880 Fax (559) 261.9707 ULE 15,16 +J NOT 109906091 , g• g �� DATE 2-2--201 S SHEET E2 OF E3 SHMM SCAM AS SH` DESIGNER Guff i�apts A DRAFTER Cliff toffs JOB LOT UNE LOT UNE 1'-6" �— W GSTC STUB ----, TUB L_c?-. �.�� RAW WATER METER MAIN TRENCH CIDi I -- -- - I -- -- R/W W Ia b LOT UNE ` TYPI CAL INTERIOR STUB INSTALLATION NO SCALE THIS CROSS SECTION IS REPRESENTATIONAL ONLY. ANY PARTY EXCEEDING ITS SPACE ALLOTMENT SHOULD MAKE ARRANGEMENTS TO ENSURE THAT THE TRENCH WILL ACCOMMODATE THE ADDED CONDUITS OR DUCTS. GAS TO GO ON SIDE OF TRENCH NEAREST THE CURB. NOTES: _ Ico - 1. PROVIDE 2" SAND SHADING ABOVE AND BELOW GAS FACILITIES JMINIMUM) T 2. PROVIDE 4" SAND SHAD NG ABOVE AND BELOW ELECTRIC FACILITIES (MINIMUM) Z N 1-+- 24" -4 72" MIN. BOTTOM OF GAS MAIN TO BE 6" ABOVE x TOP OF ANY OTHER CONDUIT/DUCT T C IN TRENCH * MINIMUM COVER FOR ANY PARTY IN THE STREET AREA IS 30" (EXCEPT STREELIGHTS) �6' MIN. FINISH GRADE TYPI CAL DISTRIBUTION TRENCH (SO -CAL GAS AREAS) NO SCALE NOTE: ALL SERVICES AND SUB --STRUCTURES ARE NOT TO SCALE FOR CLARITY. ALL COMPONENTS SHALL FIT WITHIN THE PUE OR FRANCHISE AREA UNLESS OTHERWISE NOTED. REFER TO DETAILS FOR LOCATIONS. SUBSTRUCTURE VERIFICATION STAMP DEVELOPER PLEASE NOTE AND SIGN ALL P.G.& E. ENCLOSURES AND BOXES HAVE BEEN SET TO GRADE ACCORDING TO GRADE STAKES PROVIDED BY DEVELOPERS ENGINEER. ALL COSTS TO RELOCATE OR RE -ADJUST BOXES AT A LATER DATE WILL BE BILLED TO THE DEVELOPER. PLEASE HAVE YOUR JOB SUP. VERIFY THE CORRECTED GRADE OF ALL ENCLOSURES AND BOXES. AND SIGN AND DATE DRAWING. THANK YOU SIGNED DATE 24• MIN. 59-1/2" MIN. lo' PUE PAD -MOUNTED / EQUIPMENT SUBSURFACE ENCLOSURE TRENCH CENTERLINE (1' UNDER WALK) TYPICAL INTERIOR STREET NO SCALE i8• MIN l FlNISH GRADE 1) r SAND SHADING AROUND GAS & ELECTRIC IF NATIVE SOIL IS NOT ROCK FREE 2) SEE OTHER DETAIL F NON -PG&E STREETLIGHT IS IN TRENCH 3) ONLY PARTIES PARTICIPATING IN U.S.A. ARE ALLOWED IN THIS TRENCH MIN. MIN. r SHADING TYPICAL SERVICE TRENCH NO SCALE JOINT TRENCH RECAP TRENCH OCCUPANTS DISTRIBUTION OR SERVICE TRENCH SIZE DEPTH FOOTAGE BACKFILL SURFACE GSTC DIST 24" x 59" 432' SPREAD DIRT GPTC DIST 24" x 59" 309' SPREAD DIRT GPSTC DIST 24" x 59" 1,152' SPREAD DIRT GTC DIST 24" x 59" 546' SPREAD DIRT GST DIST 24" x 59" 164' SPREAD DIRT GPT DIST 24" x 59" 82' SPREAD DIRT GT DIST 24" x 59" 175' SPREAD DIRT GSTC SERV FRANCH 18" x 46" 582' SPREAD DIRT GSTC SERV PRIVATE 1 18" x 46" 250' SPREAD DIRT GSTC ISERV COMP. 1 18" x 46" 1,350' SPREAD DIRT FOR TRENCH INSPECTION CALL (559) 263-7312 ANY CHANGES TO THIS DESIGN MUST FIRST BE APPROVED BY PG&E. GAS ADE: DOMINIC OTHART PHONE: (661) 398-5817 JOINT TRENCH COMPOSITE APPROVED BY. GAS ADE: ELECT ADE: DATE: GENERAL NOTES: 1. DEVELOPER TO DO ALL TRENCHING, SHADING, AND BACKFILLING. PER UO STANDARD S-5453. 2. PHONE AND CABLE TV FACILITIES ARE SUBJECT TO CHANGE AT THE DISCRETION OF THOSE COMPANIES. 3. PADS, BOXES AND OTHER FACILITES ARE NO SHOWN TO SCALE. 4. GAS AND ELECTRIC FACILITIES WILL REQUIRE SAND SHADING IF NATIVE SOIL IS NOT ROCK -FREE. PG&E WILL INSPECT BACKFILL MATERIAL. TEL AND/OR CAN MAY ALSO REQUIRE 12" OF SAND BACKFILL. 5. GROUND TO BE WITHIN .2 FT OF FINISH GRADE PRIOR TO TRENCHING. 6. GAS AND ELECTRIC FACILITES REQUIRE AT LEAST 3' OF SEPARATION (1' UNDISTURBED SOIL) FROM PARALLEL RUNS OF WATER, SEWER, OR STORM DRAIN. 7. PRE -CONSTRUCTION MEETING REQUIRED TWO WEEKS PRIOR TO THE START OF INSTALLATION. 8. CALL U.S.A. AT LEAST 48 HOURS PRIOR TO TRENCHING (DIAL 811) 9. PG&E WILL ASSIST IN LOCATING ENDS OF EXISTING GAS MAINS. 10. DEVELOPER IS RESPONSIBLE FOR OBTAINING ENCROACHMENT PERMITS.. 11, STREETLIGHT LOCATIONS MAY HAVE CHANGED. REFER TO THE APPROVED STREETLIGHT IMPROVEMENT PLAN FOR STREETLIGHT INSTALLATION. 12. DEVELOPER SHALL CONTACT ALL INVOLVED PARTIES PRIOR TO MAKING ANY CHANGES FROM THIS DRAWING. 13. REFER TO EACH PARTY'S INSTALLATION INSTRUCTIONS FOR MORE PRECISE DESCRIPTION OF SUBSTRUCTURES AND OTHER REQUIREMENTS. G GAS 2. P ELECTRIC PRIMARY S ELECTRIC SECONDARY T TELEPHONE CAN C CABLE TV ELEC. SEC. / SLASH INDICATES CHANGE IN OCCUPANCY --- -- — — -- PROPOSED SERVICE TRENCH -- — PROPOSED MAIN LINE TRENCH «� m Z Q EXISTING UNDERGROUND FACILITY W [2� PROPOSED ##2 (17" x 30" x 18") ELECTRIC SPLICE BOX [2E] PROPOSED ##2 (17" x 30" x 26") SECONDARY ELECTRIC SPLICE BOX RED PROPOSED ##3E (247" x 36" x 26") SECONDARY ELECTRIC SPLICE BOX LTj PROPOSED TELEPHONE PEDESTAL\SPLICE BOX LCJ PROPOSED CABLE SPLICE BOX PROPOSED PAD MOUNTED TRANSFORMER t0, INDICATES TRENCH FOOTAGE & OCCUPANCY Y� PROPOSED PRIVATE STREET LIGHT LOCATION (SEE NOTE 11) Q PROPOSED SERVICE LOCATION 1. LES INGLES 2. BRIAN FRANZ 3. GREG EOFF 4. LEON WELLS COMPANY TELEPHONE P G & E (661) 398-9755 AT&T (661) 631-3492 BRIGHTHOUSE (661) 395-3351 THE GAS CO. (661) 399-3215 MINIMUM COVER AND CLEARANCES' ROSEDALE HWY HOLLAND ST iv SITE-\ 0 o W C9 ENGER ST d 0 � TELSTAR AVE O 3 O GLENN ST NTS VICINITY MAP NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL DRAWINGS FOR ELECTRIC FACILITY PLACEMENT, DETAILS, AND CLEARANCES. • 6 5 4 3 vi 0 _Z 'S LdQ D CD �j n- W LL_ ~ 00 LL_ It0 � W m CK W n 0 F_ cl- 2 N w 1 W W cn G T I C I S I P COVER GAS — 1 1 " " " 4` 0" IN STREM TELE. 1 " - " 1 ' 1 " 247,30: STREET CAN 12 1" - 12" 12 18" ELEC. SEC. " 2" 12" - 3 24 30 STREET 30" IN STREET ELEC. PRI. i12"12"12"_3: - 30",36' STREET STREETLIGHT 6" 12"12 1" Y SEE EX.B FIG.1 ROSEDALE HWY HOLLAND ST iv SITE-\ 0 o W C9 ENGER ST d 0 � TELSTAR AVE O 3 O GLENN ST NTS VICINITY MAP NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL DRAWINGS FOR ELECTRIC FACILITY PLACEMENT, DETAILS, AND CLEARANCES. • 6 5 4 3 vi 0 _Z 'S LdQ D CD �j n- W LL_ ~ 00 LL_ It0 � W m CK W n 0 F_ cl- 2 N w 1 W W cn O Z 1— c.� W O a a N z O W C Z vs ca C14 00 rn o � C= N v p, .N ti o W H `[ C:) U O V V � J Q «� m Z Q m m W O 0 a w Q W Q >Z r d_- C> cn LL � M o a U O Lc"z rn Q O J Q cn co N _j co Lo !G H v a � =W E W � O U co U ad 00 H N W Z w N a� _m fY Z 0 a GOA+ ■ O Z 1— c.� W O a a N z O W C Z E O c � C= O 00 dyY I N v p, .N ti W H `[ C:) U O V V W O J Q «� m Z Q m m W O 0 a w Q O Z 1— c.� W O a a N z O W C Z 1 INCH 0 U z 0 i O O W Q >Z r d_- C> cn LL a U N Lc"z w Q O J Q co m: _j H W N =W E W � Y Q Q m Z 0 N _m fY 1 INCH 0 U z 0 i i E STUB FOR FUTURE 1 I I 1 I I I 1 I 10' -� I I I i i I 1 I I I 1 PUE 1 I S I i I i I I I 1 I I i P 1 I I l l I I I i I 1 3 55 54 53 1 2 3 4 5 0" 6 7 �" 8 9 �� 10 11 00 12 13 �� 14 15 �� 16 17 GO 18 19 6' EXTEND SERVICES FROM EXISTING STUB/--GGT-C\ 75, I I I I 1 I 1 I I 1 146 GSC 1(/ , 1 I PST I I 11 PST GPTC 1 PST I I 1 I 1 1 GSTC 1 16' SHORT / PUE 16' SHORT ` 381 16' SHORT 16' SHORT \ 120' S3' 16' SHORT` 182' 16' SHORT` 16' SHORT 10' 16' SHORT 336' I /16' SHORT SIDE SERVICE SIDE SERVICE SIDE SERVICE SIDE SERVICE SIDE SERVICE SIDE SERVICE SIDE SERVICE J pUE SIDE SERVICE SIDE SERVtC�i r --r-- _4 rW-t C — rw1 C �` I RUR L� i — — rN �� _ rN L�� r,�rCT ' rW� L_� rWC T lNJ LT ro T t . +. J LTJ LJ l.MJ LTJ LMJ 1 SS S ss SS 9S 6 S O ss I SS I SS SS I SS I SS 6' ss I SS ss I SS I SS SS --� D SD I TIE IN (I EXISTING JrI RIBSTON I i �..-- 3' 3 r-- 3 AVENUE 3' �° I-- 3' I-- 3' 1 I w w Wly. — •�-- — 7 n1L — — _ — 4 64' LONG 64' LONG , 64' LONG 64' LONG T— `/ SIDE SERVICE SIDE SERVICE 10—� SIDE SERVICE SIDE SERVICE 64' LONG 64' LONG 64 LONG , 64' LONG 64' LONG PUE ,/ I � f SIDE SERVICE , j SIDE SERVICE SIDE SERVICE 1�_ ,/ SIDE SERVICE ,/ SIDE SERVICES r x x PUE 1 II Q II IiI 01 50 51 52 1 36 1 35 1 34 1 33 1 32 1 31 1 30 29 I 28 I 27 I 26 I 25 I 24 I 23 I 22 I 21 ! 20 w 60 1 1 I 1 1 I 1 G'O 00 0010 � 164 S6PUE 1 I GTCLANDSCAPE METER O 1 � PUE I }- I 10' 1 W EXTEND SERVICES FROM a Q #7 INSTALLED ON PUE I EXISTING STUBS 1( J I PM: 31007969 o " v 00 I I 1 1 1 1 1 1 1 A I f I I 1 I 1 I i i I I 1 43 I 42 I 41 I 40 I 39 I 38 I 1 36 37 I 38 Z 39 I 40 I 41 42 1 43 44 45 46 47 48 I — I PST 1 1 1 PST 1 1 1 I GT, P I I116 1 0' GPTC PST 117 PST / ZO7'/ GPTC GPT PUE 68' I GPTC 16' SHORT \ 1 12�' 1s' SHORT\ %( 25' 16' SHORT \ / 10'SHOR \ / 107 16' SHORX 82' PRIMARY CONDUIT Je 37 SIDE SERVICE SIDE SERVICE SIDE SERVICE ,PUE SERVICE SIDE SERVICE INSTALLED ON - - PIP - _ PM 31007969 r..T_ C N LCJ 7 N c Lam, rN L�.,i rN C rN LC -T - TT k L LJ LTJ LJ LJ LTJ LJ W W S N CD rn OQ C N 4VIX o C11-4 0 o ci m =5 o o _ V U Z O t/> O ami v� a� N ,N ^ E-1 Of o 00 V � c m N Q ^ H z w v 0 'am W Z O ■ c� O Vf m v N 1.._ U rn N M '' m Le Z Co 0 it V w .i Z O Lo V O Q QCL_ Q C> o. W o Q N s .r... 011 S SD SD D SD — 6 SS ^ S SS SS SS SS SS SS Ss S S SS O SS SS SS SS RI R too TIE INTO GSTC EXIS ING JT 48'� GTC AVENUE co 59C GT I w _ _ _ _ 59 5 r,� 59' N — NI , w I '-�- ��� ROPE TRENCHES S 3' � 16' SERVICE 10 A,`16' SERVICE ' AROUND FH 5' U 5' STUB FOR PUE y '` 8 r�, FUTURE ( I r- STUB FOR g STUB FOR I I I I I I I I W FUTURE FUTURE 28 29 30 31 32 33 34 35 49 50 51 52 53 54 I W i cn 1 1 1 I I I -- I H ------1 EXTEND SERVICES FROM v v v v-- Z 10 ' 0 N v EXISTING STUB Z v v PUE I — m Q O (Al V 10 60 29 O 1 3 U LA -6-J.- 481 47 46 45 44 43 42 41 40 39 38 37 36 1 QN1 1 1 1 1r -i Psi 1 1 NOTE: ALL SERVICES AND SUB --STRUCTURES ARE NOT TO SCALE FOR CLARITY. ALL COMPONENTS SHALL FIT WITHIN THE PUE OR FRANCHISE AREA UNLESS OTHERWISE NOTED. REFER TO DETAILS FOR LOCATIONS. V) W S 6 28 11 w 3I I� J i 1 W W "2E-4 Q O L.LJ Q rx4l 0 q: 0 O F— J o � M TV CO o QW Lo E, W L" N Z W V E- m Q W O O cn M z cr_ NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL W W 2 z DRAWINGS FOR ELECTRIC FACILITY PLACEMENT, DETAILS, AND CLEARANCES. 8 �, a O 6 5 4 3 2 1 INCH 0 LEGEND INSTALL DESCRIPTION ---r--P------P--P -- PRIMARY CABLE - 1-1/OAL EPR ENCAP IN EXISTING 1-2` CONDUIT —P7 P1 PRIMARY CABLE - 1-1/0AL EPR ENCAP IN NEW 1-Z" CONDUIT -------S1 S1 SECONDARY CABLE - 4/0AT. TPX IN NEW 1--3" CONDUIT 2----'S2 SECONDARY CABLE - 350AL TPX IN NEW 1-4` CONDUIT 54-----54--*'— SECONDARY CABLE - 4/0AL TPX IN EXISTING 1-3" CONDUIT ------ W ------ S5---- SECONDARY CABLE - 350AL TPX IN EXISTING 1-3" CONDUIT --yy----�y�------ SERVICE CABLE - 4/OAL TPX -IN NEW 1-3" CONDUIT -----sVt---'SV1 SERVICE CABLE - 1/OAL TPX IN NEW 1-3" CONDUIT -----SY2--- S'V2 SERVICE CABLE - 4/0AL TPX IN EXISTING 1-3" CONDUIT STREETLIGHT CABLE EXISTING DESCRIPTION T-72604 3PHASE PRIMARY CABLE/CONDUCTOR - SIZE AS SHOWN �.. 1 PHASE PRIMARY CABLE/CONDUCTOR - SIZE AS SHOWN .,... _ ._. ..-. _ VACANT CONDUIT (PRIMARY} - SIZE AS SHOWN INSTALL EXISTING DESCRIPTION X20 171 17' x 30' x 18" SECONDARY BOX tE 17' x 30' x 26" SECONDARY BOX C3U 24" x 36" x 18" SECONDARY BOX 3E 24" x 36" x 26" SECONDARY BOX [CE) L� 0 3' x 5' x 3'6" PRIMARY ENCLOSURE 14 CUST 1 W/2B 90 0 4'6" x 8'6" x 6' PRIMARY ENCLOSURE 120/240V PM TRANSFORMER, DF—LB. SIZE AS SHOWN r, LS2A STREET LIGHT 1. THIS IS AN APPLICANT DESIGN AND INSTALL PROJECT. 2. TRENCH TO BE JOINT WITH ELECTRIC, GAS, PHONE & CATV. 3. APPLICANT SHALL OBTAIN ALL NECESSARY PERMITS.. 4. RIGID CAP ALL SPARE CONDUITS. 5. IMPORTANT! DEVELOPER, GENERAL & ELECTRICAL CONTRACTOR BEFORE BEGINNING SUBSTRUCTURE WORK, PLEASE CONTACT PGE UNDERGROUND TRENCH INSPECTOR AT LEAST TWO BUSINESS DAYS PRIOR TO REQUESTING INSPECTION. REQUEST FOR INSPECTIONS RECEIVED AFTER 12:OOPM WILL NOT BE INSPECTED UNTIL THE 3RD WORKING DAY. FAX 0 661-398-5985 CALL 0 661-398-5711 (WORK N T PROPERLY INSPECTED MAY BE REJEUE 6. APPLICANT CONTRACTOR TO LOCATE ALL UNDERGROUND FACILITIES BEFORE TRENCH & EXCAVATION. CALL UNDERGROUND SERVICE ALERT AT 811 AT LEAST TWO WORKING DAYS PRIOR TO DIGGING. 7. SECONDARY AND SERVICE CONDUITS SHALL ENTER BOXES FROM UNDERNEATH WITH 90 DEGREE VERTICAL BENDS, EXCEPT FOR BOXES ADJACENT TO TRANSFORMERS. 8. DO NOT EXCEED 300 DEGREES OF BENDS IN ANY CONDUIT RUN (INCLUDING BEND AT THE FEED LOCATION). 9. PROVIDE CLEARANCES AND WORKING SPACE PER PGE DWG. 051122. 10. PGE SHALL INSPECT ALL WORK AND PERFORM ALL HOT TIE-IN WORK. 11. CONDUIT SIZES AND LOCATIONS SHALL CONFORM TO THE PGE ELECTRIC CONSTRUCTION DWG 062288. 12. ENCLOSURES SHALL CONFORM TO THE PGE ELECTRIC CONSTRUCTION DWG. 062000. 13. APPLICANTS CONTRACTOR TO PERFORM ALL AND ANY NECESSARY INCIDENTAL TRENCHING, BACKFILL, COMPACTION AND PAVING. 14, SEE UTILITY COMPOSITE DRAWING FOR ACTUAL TRENCH & SUBSTRUCTURE LOCATIONS 15. APPLICANT TO PROVIDED PLIES AND RIGHTS OF WAY AS REQUIRED. 16. 800 SERIES SKETCH LOCATIONS INDICATE PG&E WORK. CABLE PULLING DATA LOC 17 TO LOC 7 24 LOC 35 TO LOC 23 USE 2.5 -GAL & 2- FRONT END PKS. USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 20OLBS. EST. PULL 151 LBS. ACTUAL PULL ........... LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS .......... FOREMAN'S INITIALS .......... LOC 801 TO LOC 804 LOC 800 TO LOC 806 USE 2.5 -GAL & 2- FRONT END PKS. USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 20OLBS. EST. PULL 221 LBS. ACTUAL PULL ...... ..... LBS. ACTUAL PULL ........... LBS. FOREMAN'S INITIALS .......... FOREMAN'S INITIALS .......... ENVIRONMENTAL ISSUES i� NONE APPARENT (IF PROJECT DESIGN CHANGES. CONTACT ADE) CI BASED ON APPLICANT/DEVELOPER-SUPPLIED PLANS ❑ PERMITS ❑ TAILBOARD ❑ OTHER ❑ APPLICANT DESIGN/RESPONSIBILITY (CHECK PERMITS BOX IF PERMIT CONDITIONS APPLY TO PG&E ACTIONS.) SIGNATURE TRANSFORMER DATA TABLE LOC.# TRF# TX. SIZE #CUST WIRE BUSH. ESD. KVA. PRL VOLTS SEC., VOLTS COORDINATE # SERIAL NUMBER MANUFACTURER 801 74, T-55746 100KVA 17 CUST 1W/2B 107 21 KV 120/240V 17 T-72604 100KVA 17 OUST 1W/2B 108 21 KV 120/240V + IRR METER [CE) T-80619 100KVA 14 CUST 1 W/2B 90 21 KV 120/240V TYPICAL 36" X 52" PAD DETAIL 36» p Owup AN Secor dwy Conduft Togedr Now to Baedc of tlta' OWow Pdmay C*nM $ cftn of Pad ALL RES SERVICES ARE INVENTORIED AT LOC SEE JOB INSTRUCTIONS FOR CONDUIT IN 41 FRANCHISE AND PRIVATE PROPERTY. CALL TWO WOFMG DAYS BEFORE YOU DIG NO GAS CONFLICTS IDENTIFIED FOR THIS PROJECT NON—PG&E GAS AREA [li A Placement of Conduits APPLICANT TO TRENCH, BACKFILL, INSTALL ALL SUBSTRUCTURE, AND INSTALL ALL DIST FACILITIES. PG&E TO PERFORM TIE IN WORK AND INSTALL. SERVICE FACILITIES. THIS SKETCH IS INTENDED FOR ELECTRIC CONSTRUCTION ONLY PLEASE SEE JOINT TRENCH COMPOSITE FOR TRENCHING DETAILS AND SUBSTRUCTURE INSTALLATION DETAILS THESE DRAWINGS ARE CONSIDERED PRELIMINARY AND AT RISK, UNLESS STAMPED AND APPROVED BY PG&E AND P.E. Waxi 0f1c1,4 not relvf c f+ic fipplicni -Tim­a;;,sihii i ;t� t I,� 1,ni ittoa mil' •jS JQai ��� :tk',)i 'W.2. GENERAL DESIGN INFORMATION: STREET LIGHTS — LS2A AVG HOUSE SIZE BASED ON 1800 SQ FT HOME 200 AMP MAIN PANELS SCI 10,000 AT ALL PANELS 5 TON A/C UNITS. (170 LRA) PLAT 2927293 CIR MAP 29276B INS DIST. B KERN POWER 2103 CLIMATE ZONE R VOLT CLASS 1 SUMMER INTERIOR LIGHTNING DIST: 2 NON --CORROSIVE SSD: 95027 Lq�p�Ips�p��U/�ry��/f y D 3*n S{�OMtces SCALE: 1 "=40' SCALE 40' 0 40' 80' LkL P E 5 IT' DESIGN SERVICES) NIX Ff Electric Design by: ELECTRIC CONSTRUC110N SKETCH A L qwu P E TRACT 8853 PHASE 2 UTILITY DESIGN SERVICES RI BSTO N AVE & EL TORO WI EJC) RD OfflCte (559) 6412954 46325 Wallu lane Cell (559) 760 9464 Ahmhnee, Callfbmla 93601 BAKERSFIELD CALIFORNIA, � Ij Project Management by: 57 R. 1-1/0AL 21 KV 2" I t MIa rn� 1 .V--ww------ ---- C rFD FD CALC URED ON PH 1 30993115 5.2 5.3 619 74' v 74' _4/0AL LAL /OAL 3" ..... .... 1t RIB STON� a AVENUE, ...... ..._ r... ..-. SEE PM 30993115 EXISTING PHASE 1 SEE PM 31007969 EXISTING R20C 46 45 I 45 W V) 54 I 53 T-26781 100KVA 12 EX CUST 2 NEW CUST 90KVA ORIGINAL DESIGN LOAD 120-EXIST/134' 801 74, �2 - 4/OAL 3" N 49 1 50 1 51 44 1 43 I 42 4/OAL 3" 4/OAL 3" -1 /OAL 21 KV 2" N TO SW -82157 3-1100AL 21 KV 6" I a WOLF RIVER i AVENUE I J-3�34--089 26 M � � I (jaR r) CN 00I i gi I 24 California U ' 'ty Consultants Inc 7591 N Ingram Ave. Suite 103 Fresno, CA 93711 Phone (559) 261-9880 Fax (559) 261-9707 27 T-83953 1OOKVA /OAL 3_ *\ Exp DAZE 3/5/2015 SHEET RULE 15 916 Sc" AS SHM PM 31124803 El NOT 109906091 NO. REVS10N BY M\,f&Desip y: 7L*P E 5 UTILITY DESIGN smVic s Office (559) 641 2954 46325 Wailu Lane Celt (559) 760 9464 Ahwahnee, Callfbmia 93601 E�CTRIC CC3I�STR�JCT1®M SKETCH TRACT 6853 PHASE 2 RIBSTON AVE & EL TORO 'VIEJO RD BAKOGRa i MF IA 800-22 - W ��" Project M�nage�ment by: California Utility Consultants Inc � 7591 N hipam Ave. Suite 103 Fi+esno, CA 93711 Phone (559) 261-9880 Fax (559) 261-9707 RULE 15,1 � PM 31124803 NOT 109906091. - 53' DA"C"E 3/5/2015 SHEET E2 of E3 SHEM sc� Asp oE��� �'i°� c tow a ,dos DETAIL "A" A-2 A-1 A EXISTING 4" PE NEIN 4" PE NOT TO SCALE Gas Handling g PLANNED BY: D. MCCLEAN CONSTRUCTION sri. GOFORTH DATE: DATE: 4-28-15 BASE BY: DLK COMPLETION BY: I I of = 50 1. Install & Test all Pipe & Fittings from Loc Location B ( Test @ 100 #s With air for 20 S.I. 184.005, 184.0140 & 184.0095. 2.Install & Test all Pipe & Fittings from Loc., Location F ( Test @a 100 #s with air for 20 S.I. 184.0059 184.0140 & 184.0095. 3. Verify Pressure a@ Locations A2 & C2 (421 Through Entire Process 4. S queeze Main a@ Locations Al & C1. 5 .Tie in Main @ Locations A & C 6. Relax squeeze P, Locations Al & Cl to pack main. 7. Purge by Direct Method ( Air to Gas) to 100% Gas From Location A to Location B and From Location C Locations D,E & F per S.I. 184.0160. Verify 100% Gas with Gas Scope. 8. Complete and Leak Test with soap all Fittings, squeezes And pipe. 9. Complete all related service work. PLOT INFO: 5/19/2015 7:47:01 AM DETAIL "C" C-2 C 1 C EXISTING 4" PE NEW 4" PE NOT TO SCALE DATE:01.06-15 SHEET 1 OF 1 WFM CURRENT OWNER & DATE DATE: jr9of0ri 511912015 PRE CONSTRUCTION MEETING: YES E NO REQUIRED WITH A GAS COMPANY REPRESENTATIVE LOCATION INFORMATION THOMAS GUIDE PAGE # 2441-E4 J I I AFFECTED FACILITIES I DIST. PRESS. / MAOP: 60 SET/ MOP: 50 ) SUPPLY PCB - MEGARULE N/A PCB FREE AREA 0 HOT SPOT E HOT DISTRICT ANNUAL I BUSINESS LEAK SURVEY AREA:/ POST LIMITS ON SKETCH IF APPLICABLEZ YES NO W$ CATHODICALLY PROTECTED: YES in NO CP AREA # DATE: PHONE # BRIDGE OR SPAN INVOLVED: YES IM NO WILL ANY PIPE BE LEFT EXPOSED: YES IM NO (IF YES ROUTE AS -BUILT COPY TO SP SUPERVISOR) ENVIRONMENTAL CLEARANCE REQUIRED - YES NO b ISSUED BY: DATE: STORM WATER: BMPS ONLY ® SCG SWPPP IM APPLICANT SWPPP 11 WA SPECIAL ENVIRONMENTAL CONSIDERATIONS: YES jj NO C (IF YES SEE REGION ENVIRONMENTAL ADVISOR)) MISCELLANEOUS PLANNING STAKED.EM STAKING REQUIRED: YES 11 NO VALVES REQUIRED YES IN NO PIPELINE MARKERS REQUIRED: YES NO OF YES DISPLAY LOCATION) JOINTTRENCH: YES BY: ISSUED BY. REVIEWED: PRINT NAME: DATE: PA / FPA AREA MGR. REVIEWED: PRINT NAME: DATE: t— LSPS - --- - =� ABANDON PIPELINE SAMPLING REQUIRED (PER GAS STANDARD 104.0042) YES IM NO BY. DATE: (CHANGE LABOR TO MNK)# 99300.000) CROSSING SEINER LATERALS: YES E NO NUMBER OF LATERALS CLEARED: METHOD(S) USED TO VERIFY LOCATION(S): OPEN TRENCH IM CAMERA IM POTHOLEIM EXPOSED BY EXCAVATION J1 (GAS STD #184.0170) OTHER IM METHOD: IF A POSnTk/E LOCATION COULD NOT BE DETERMINED INDICATE THE ADDRESSILOCATX)N AND REASON WHY ON THIS SKETCH. LCT DATE DESIGN CHANGES v WERE CHANGES MADE TO THE YES NO 11 0 DESIGNED PIPE OR COMPONENT PF YES TECHNICAL SERVICES APPROVAL IS REQUIRED) W_ REGION ENG: DATE FL UPDATED TO RER # TSS: DATE: LPA 1 PA / FPA: DATE: BACKFILL TYPE USED MECHANICAL COMPACTION: YES 19 NO IN GAS HANDLING REVIEWED AND PERFORMED AS YES NO IM PLANNED PER GAS STD #184.06: (IF NO PLEASE PROVIDE EXPLANATION ON SKETCH) SIGN: DATE: PRINT NAME / TITLE: CONSTRUCTION CREW FOREMAN: COMPANY 0 TOTAL FEET TOTAL FEET DATE MOVED DATE OF DATE MOVED INSTALL MAIN WITH ATIMAST: 30" RETIREMENT INSTALLED: RETIRED: ON JOB: _ OPERATION: OFF JOB: COVER BELOW: GRADE REASON: r 11lr µ WORK CENTER # CGD WB5 # DIT r v NBMS # 0OW180723 WC}T PARCEL # 107986 raSoCalGaS DREAMS* RNV# WA KNOW bdomL DESIGN # DESIGN NAME: CdolbdWynalgg. a Sempra Energy uUatr ORDER OP* CAD FILE: TICKET # NOTIFICATION # 000030018148 PLAN FILE # WA F co RER # WA a U. Cl) O TAX # o z