Loading...
HomeMy WebLinkAboutFIRE PREV. INSP 9/22/2015Kern Business Forms (661) 325 -5818 - KBF -7320 BAKERSFIELD FIRE DEPARTMENT .FIRE PREVENTION INSPECTION _.-R S F Prevention services B E R 5 F I D FIRE 2101 H Street ARTM r Bakersfield, CA 93301 Phone: 661 -326 -3979 • Fax: 661 - 852 -2171 DISTRICT BLOCK NO. DATE '24 M i FEE FACILITY ADDRESS d - '.�^�. ''> - _.`"•. t�? �'l CITY, STATE, ZIP p_� , I ...'"`st=E °' ^- C 7�C_i .�11 . C.... f..;' l ✓`' i '�` FACILITY NAME MANAGER'S NAPE PH NO. ,7 BUSINESS OWNER'S NAME. AND n ADDRESS CITY, STATE, z P PH NO. 3 i.'s BILL TO: (IF DIFFERENT FROM ABOVE) NAME, ADDRESS CITY, STATE, ZIP, PH NO. OCC TYPE OCC LOAD NO. OF FLOORS HIGH RISE BLDG RISER DATE ❑ YES ,EJ NO CORRECT ALL VIOLATIONS vioLATION REQUIREMENTS CHECKED BELOW No. 1 Remove and safely dispose of all hazardous refuse and dry vegetation on the above premises (CFC COMBUSTIBLE WASTE / DRY 304.1.1) VEGETATION 2 Provide non- combustible containers with tight .fitting lids for the storage of combustible waste and rubbish pending its safe disposal. (CFC 304.3.2) Note: applies to containers over 40 gallons. COMBUSTIBLE STORAGE 3 Relocate combustible storage to provide at Feast 3 feet clearance around motor fuse box /fire door (CFC 605.3) 4 Relocate fire extinguisher(s) so that they will be in a conspicuous location, hanging on brackets with the top.to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9) EXTINGUISHERS 5 _____ _________ _________ portable fire Provide and install (amount) approved (type & size) extinguisher to be immediately accessible for use in (area) __ ___________________________ (CFC TABLE 906.3(1)) 6 Re- charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and /or after each use, by a person having a valid license or certificate. (CFC 906.2) 7 Provide and maintain "EXIT" sign(s) with letters 6 or more inches in height over each required exit SIGNS (door /window) to fire escape. (CFC 10.11) 8 Provide and maintain appropriate numbers on a contrasting background and visible from the street to indicate the correct address of the building. (CFC 505.1) 9 Repair all (cracks /holes /openings) in plaster in (location) ______________ FIRE DOORS/ FIRE SEPARATIONS Plastering shall return the surface to its original fire resistive condition. -(CFC 703.1) 10 Remove /repair (item & location) ______ __ ___ ________— ________ __ _ _ Self- closing doors shall be designed to close by gravity, or by the action of a mechanical_ device, or by an approved smoke and heat sensitive device. Self- closing doors shall have no attachments capable of preventing the operation of the closing device. (CFC 703.2) EXITS .11 Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1028.3) 12 Provide a contrasting colored and permanently installed electric light over or near required exit (location) !________ ____ ____________ _____ to clearly indicate it as an exit. (CFC 1006.3) STORAGE 13 Remove all storage and /or other obstructions from fire escape landings and stairways stair shafts. (Fire escapes /stair shafts are to be maintained free from obstructions at all times.) (CFC 1003.6) 14 Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved ELECTRICAL APPLIANCES electrical outlets where needed. (CFC 605.5) 15 Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) (CFC 605.4) OUTDOOR BURNING 16 Recreational fires or open burning. CFC 307.1 FIREWORKS 17 Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.). OTHER 1$ CORRECTION DATE Correct the violations noted above by: LEGEND: C.F.C. CALIFORNIA FIRE CODE C.B.C. CALIFORNIA BUILDING CODE CUSTOMER: MUNICIPAL CODE (Signature) (Please Print Name Legibly, Title) B.M.C: BAKERSFIELD N.F.P.A. NATIONAL FIRE PROTECTION INSPECTOR: s�' l '`���" \ -Y�`"` IVO. rw' ASSOCIATION N.E.C. NATIONAL ELECTRIC CODE