CORRECT ALL VIOLATIONS vioLATION
REQUIREMENTS
CHECKED BELOW No.
1
Remove and safely dispose of all hazardous refuse and dry vegetation on the above premises (CFC
COMBUSTIBLE WASTE / DRY
304.1.1)
VEGETATION
2
Provide non- combustible containers with tight .fitting lids for the storage of combustible waste and
rubbish pending its safe disposal. (CFC 304.3.2) Note: applies to containers over 40 gallons.
COMBUSTIBLE STORAGE
3
Relocate combustible storage to provide at Feast 3 feet clearance around motor fuse box /fire door (CFC
605.3)
4
Relocate fire extinguisher(s) so that they will be in a conspicuous location, hanging on brackets with the
top.to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9)
EXTINGUISHERS
5
_____ _________ _________ portable fire
Provide and install (amount) approved (type & size)
extinguisher to be immediately accessible for use in (area) __ ___________________________ (CFC
TABLE 906.3(1))
6
Re- charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and /or
after each use, by a person having a valid license or certificate. (CFC 906.2)
7
Provide and maintain "EXIT" sign(s) with letters 6 or more inches in height over each required exit
SIGNS
(door /window) to fire escape. (CFC 10.11)
8
Provide and maintain appropriate numbers on a contrasting background and visible from the street to
indicate the correct address of the building. (CFC 505.1)
9
Repair all (cracks /holes /openings) in plaster in (location) ______________
FIRE DOORS/
FIRE SEPARATIONS
Plastering shall return the surface to its original fire resistive condition. -(CFC 703.1)
10
Remove /repair (item & location) ______ __ ___ ________— ________ __ _ _
Self- closing doors shall be designed to close by gravity, or by the action of a mechanical_ device, or by an
approved smoke and heat sensitive device. Self- closing doors shall have no attachments capable of
preventing the operation of the closing device. (CFC 703.2)
EXITS
.11
Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1028.3)
12
Provide a contrasting colored and permanently installed electric light over or near required exit
(location) !________ ____ ____________ _____ to clearly indicate it as an exit. (CFC 1006.3)
STORAGE
13
Remove all storage and /or other obstructions from fire escape landings and stairways stair shafts. (Fire
escapes /stair shafts are to be maintained free from obstructions at all times.) (CFC 1003.6)
14
Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved
ELECTRICAL APPLIANCES
electrical outlets where needed. (CFC 605.5)
15
Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) (CFC
605.4)
OUTDOOR BURNING
16
Recreational fires or open burning. CFC 307.1
FIREWORKS
17
Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.).
OTHER
1$
CORRECTION DATE
Correct the violations noted above by: