HomeMy WebLinkAbout1.4-6419 Ph 1 Record Drawing- CITY OF BAKERSFIELD INTHF COUNTY OF KERN STATE OF CALIFORNIA Block Wall Construction Plans TRACT 6419 -PHASE 1 GENERAL NOTES 1. WALL: HEIGHT VARIES (SEE PLANS) COLOR: TO BE DETERMINED BY OWNER CAP: GROUTED DESIGN WIND: 70 MPH 2. ALL STATIONING DATA WAS CALCULATED FROM CENTERLINE, OFFSETS ARE TO THE LANDSCAPE EASEMENT. 3. HEIGHT OF WALL SHALL BE 9'-0" MAX. MEASURED FROM GROUND AT HIGHEST SIDE OF WALL. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR CLEARING AND GRADING THE AREA ALONG THE WALL LINE. 5. CONTRACTOR SHALL OBTAIN AND PROVIDE ALL PERMITS REQUIRED BY CITY OF BAKERSFIELD PUBLIC WORKS DEPARTMENT RIVERTON STREET AND/OR ENGINEERING & SURVEY SERVICES. 6. ALL SURVEYING REQUIRED SHALL BE PROVIDED INITIALLY BY DEVELOPER ON A ONE TIME ONLY BASIS. ALL OTHERS WILL - - _ - - - - - - - - - - - -- BE -BE CHARGED OUT ON AN HOURLY BASIS. 7. BEARING SOIL SHALL BE COMPACTED TO 90% OF MAXIMUM DRY DENSITY AS DETERMINED BY A.S.T.M. D-1557 TOA --- DEPTH OF 12 INCHES BELOW BOTTOM OF FOOTING. 8 WATER NG. ALL OTHER SURFACES ABOVDE THE FOOTING BSHALLCBETSEALEDTWITH PORTION BELOW LOTPADS RDE DOWN SURFACE SHALL BE PER 1997 ONLY AS "AQUA -SEAL', OR APPROVED EQUAL. I - - - - - - - - - - - - - PRAD 0 DEL REY COURT 9. EXPANSION JOINTS SHALL BE CONSTRUCTED AT MAXIMUM 96 FOOT INTERVALS. EXPANSION JOINTS SHALL BE FREE OF ALL MORTAR AND GROUT FROM TOP OF FOOTING TO TOP OF WALL. Iti T F-1 10. BLOCKS AND BRICKS SHALL BE SET ON GRADE, TRUE, PLUMB, AND STRAIGHT. CURVES SHALL BE LAID OUT ON NO i A TIRRA MERIDIAN WAY GREATER THAN 8 FOOT CHORDS. HORIZONTAL MORTAR COURSES ON BLOCK SHALL BE 1/2 INCH, +/-1/8 INCH. ALL REINFORCING STEEL SHALL BE TIED FIRMLY IN PLACE PRIOR TO PLACEMENT OF BLOCK. OPEN END BLOCK WILL BE ALLOWED IN GROUTED CELLS ONLY. NO BROKEN BLOCK WILL BE ALLOWED. ALL CONSTRUCTION OF NON -MODULAR PIECES SHALL BE DONE WITH SAWCUTS. REINFORCING STEEL SPLICES SHALL BE A MINIMUM OF THIRTY -INCHES (30"). I p 1.4 11. BLOCK COLOR SHALL BE UNIFORM IN TEXTURE AND COLOR. L- V RIVIERA DEL SOL DRIVE 12. CONTRACTOR SHALL VERIFY LOCATION OF UTILITIES PRIOR TO COMMENCEMENT OF WORK AND NOTIFY ENGINEER IF CONFLICT WITH UTILITIES EXISTS. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRS TO DAMAGED UTILITIES CAUSED BYSN HIS FORCES, BUT NOT COSTS TO RELOCATE IN THE EVENT OF PROPER NOTIFICATION AHEAD OF THE CONSTRUCTION.' 13. ALL PROPER SAFETY PRECAUTIONS, INCLUDING SHORING AND BRACING OF WALL SHALL BE PROVIDED BY THE CONTRACTOR, ESPECIALLY IN THE EVENT THAT FULL HEIGHT GROUTING METHOD IS USED. -- --- 14. AN OPEN STREET PERMIT SHALL BE OBTAINED FROM THE CITY OF BAKERSFIELD PUBLIC WORKS DEPARTMENT FOR ANY i ' ARENA BLANCA WAY WORK PERFORMED WITHIN EXISTING ACCEPTED STREET' RIGHT OF WAY. UNLESS SECURED BY A SUBDIVISION AGREEMENT, � A DEPOSIT BASED ON AN APPROVED ENGINEER'S ESTIMATE FOR THE WORK PERFORMED WITHIN THE RIGHT OF WAY AND INSURANCE SHALL BE POSTED PRIOR TO ISSURANCE OF THE PERMIT. i 15. FOOTINGS SHALL NOT EXCEED THE WIDTH SHOWN ON THE PLANS BY MORE THAN 2 INCHES. ANY FORM WORK NECESSARY TO MAINTAIN THIS FOOTING WIDTH SHALL EXTEND BELOW THE FINISHED TOP OF GRADE AT LEAST 16 INCHES ' ; MAR AZUL WAY OR THE DEPTH OF THE FOOTING, WHICHEVER IS LESS. 16. ALL CONSTRUCTION EQUIPMENT SHALL BE PROPERLY AND ROUTINELY MAINTAINED, AS RECOMMENDED BY MANUFACTURER Ln MANUALS, TO CONTROL EXHAUST EMISSIONS.17. CONSTRUCTION EQUIPMENT SHALL BE SHUT DOWN WHEN NOT IN USE FOR EXTENDED PERIODS OF TIME TO REDUCE _ _ _ aizj _ _ __rmn _ _ EMISSIONS ASSOCIATED WITH IDLING ENGINES. SHEET 2 TORTUGA DEL MAR DRIVE 18. ELECTRIC CONSTRUCTION EQUIPMENT SHOULD BE USED WHENEVER POSSIBLE IN LIEU OF FOSSIL FUEL -FIRED EQUIPMENT. OOL 19. FUGITIVE DUST EMISSIONS FROM ALL DISTURBED AREAS, INCLUDING STORAGE PILES, WHICH ARE NOT BEING ACTIVELY UTILIZED FOR CONSTRUCTION PURPOSES, SHALL BE STABILIZED USING WATER, CHEMICAL STABILIZERS/SUPPRESSANTS, COVERED WITH A TARP OR OTHER SUITABLE COVER, OR PLANTED WITH VEGETATIVE GROUND COVER. 20. FUGITIVE DUST EMISSIONS FROM ALL ON-SITE UNPAVED ROADS AND OFF-SITE ACCESS ROADS SHALL BE STABILIZED THROUGH THE USE OF WATER OR CHEMICAL STABILIZERS/SUPPRESSANTS. �..._ _ 21. FUGITIVE DUST EMISSIONS FROM ALL LAND CLEARING, GRUBBING, SCRAPING, EXCAVATION, LAND LEVELING, GRADING, CUT AND FILL, AND DEMOLITION ACTIVITIES SHALL BE CONTROLLED BY APPLYING WATER OR BY PRESOAKING. 22. WHEN MATERIALS ARE TRANSPORTED OFF SITE, ALL MATERIAL SHALL BE COVERED OR EFFECTIVELY WETTED TO LIMIT I 51T 1-C{'Q(w4 ...... VISIBLE DUST EMISSIONS, AND AT LEAST SIX INCHES OF FREEBOARD SPACE FROM HE TOP OF THE CONTAINER SHALL BE MAINTAINED. 3'+ Ar �_.. 23. ALL OPERATIONS SHALL LIMIT OR EXPEDITIOUSLY REMOVE THE ACCUMULATION OF MUD OR DIRT FROM ADJACENT PUBLIC STREETS AT THE END OF EACH WORK Y SUFFICIENTE OF TO ROTARY THE RUSHES VIS BLE DUST EMISSIONS. OHI BITED EXCEPT WHERE PRECEDED OR ACCOMPANIED BUSE OF BLOWER U-19� fIo 11I 4'S � DEVICES IS EXPRESSLY FORBIDDEN). 4z 24. FUGITIVE DUST EMISSIONS SHALL BE CONTROLLED WITH THE APPLICATION OF SUFFICIENT WATER OR CHEMICAL - STABILIZERS/SUPPRESSANTS WHENEVER MATERIALS ARE ADDED TO, OR REMOVED FROM, OUTDOOR STORAGE PILES.V5i 25. VEGETATION COVER ON THE SITE SHALL BE RETAINED UNTIL CONSTRUCTION BEGINS. ►tl PD. JzOt> 26. PRIOR TO THE START OF ANY PHASE OF CONSTRUCTION THE CITY CONSTRUCTION INSPECTION DEPARTMENT AND PARKS DEPARTMENT SHALL BE GIVEN 24 HOURS NOTICE. CITY CONSTRUCTION INSPECTION DEPARTMENT 326-3049 PARKS DEPARTMENT 326-3117 27. PRIOR TO INSTALLATION OF ANY SIGNAGE, THE SUBDIVIDER SHALL SUBMIT TWO COPIES OF THE SUBDIVISION IDENTIFICATION SIGN PLANS TO THE BUILDING DIRECTOR FOR REVIEW AND APPROVAL PURSUANT TO BMC SECTION 17.60.11O(N). ONE COPY OF THE SIGN PLAN SHALL BE SUBMITTED TO THE PARKS DIVISION FOR REVIEW AND APPROVAL. SIGN PLANS SHALL INCLUDE COPY, DIMENSIONS, COLOR, MATERIAL, LIGHTING, ANCHORAGE, AND LOCATION OF SIGN(S). APPROVAL OF THESE WALL PLANS BY THE PUBLIC WORKS DIRECTOR DOES NOT INCLUDE APPROVAL OF ANY SIGNAGE. SHEETINDEX 28. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION AND/OR REPAIR OF EXISTING IRRIGATION EQUIPTMENT AND PROTECTION AND/OR REPLACEMENT OF EXISTING PLANT MATERIAL. ALL REPAIRS AND REPLACEMENTS MUST BE 1, COVER SHEET COMPLETED BY A LICENSED LANDSCAPER. IN LIEU OF THE USE OF A LICENSED LANDSCAPER THE CONTRACTOR WILL BE RESPONSIBLE FOR SUBMITTING AN IRRIGATION MODIFICATION PLAN FOR REVIEW AND APPROVAL BY THE PARKS DIVISION PRIOR TO ANY REPAIRS OR REPLACEMENT TAKING PLACE. FURTHERMORE, IT IS THE CONTRACTOR'S RESPONSIBLITY TO 2. PLAN AND PROFILE CALLOWAY DRIVE INSURE THAT ALL EXISTING PLANT MATERIAL THAT IS AFFECTED BY THE WALL CONSTRUCTION ACTIVITIES RECEIVE AN u _ ` ADEQUATE AMOUNT OF WATER TO INSURE HEALTHY PLANT GROWTH DURING THE ENTIRE CONSTRUCTION PHASE /�\ Wp� Lv� - I�iy� O" ZSR CA�tt.0 �i lw„G.' KEY MAP r rr NtTr rP W 3. wgtr5 DATE UE 200' 0 200' SCALE: 1"= 200' BENCH MARK "Top of concrete monument at the intersection of Snow Road and Quail Creek Road, also the North 114 corner of Section 8, 29127 Elevation = 401.06 Ne tC.C.G.F D-&. 41%. Pg. 22 A� Tr. X09 WIA4 ptahc VIUNI I Y MAr NOT TO SCALE GENERAL STRUCTURAL NOTES GENERAL A. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH APPLICABLE SECTIONS OF THE UNIFORM BUILDING CODE (UBC) 1997 EDITION. AND KERN COUNTY DEVELOPMENT STANDARDS, LATEST EDITIONS. FOUNDATIONS A. FOR ALLOWABLE SOIL BEARING VALUES REFER TO THE SOIL BEARING SCHEDULE OR THE SOILS REPORT PROJECT NO. B1005-12-01 DATED 01/10/06 BY GEOCON INLAND EMPIRE, INC. GEOTECHNICAL CONSULTANTS. 1. REINFORCING: DEFORMED ASTM, A615, GRADE 4 2. CEMENT: PORTLAND CEMENT, TYPE II, ASTM C-150 3. AGGREGATE: ASTM C-33 4. WATER: CLEAN AND DRINKABLE. B. CONCRETE MIX DESIGN FOR FOOTINGS AND WALL GROUTING 1. CLASS B CONCRETE, 2500 PSI ® 28 DAYS 2. 5.0 SACKS OF CEMENT (MIN.) PER CUBIC YARD 3. 1 1/2" AGGREGATE (MAX.) 4. 4' SLUMP (MAX.) C. ADMIXTURES: ONLY AS APPROVED BY THE ENGINEER. 1. CONCRETE BLOCK MASONRY UNITS: ASTM C-90 2. REINFORCING MATERIALS: ASTM A515, GRADE 40 DEFORMED 3. ADMIXTURES: ONLY AS APPROVED BY THE ENGINEER B. MORTAR 1. STRENGTH: TYPE S, 1200 PSI ® 7 DAYS AND 2500 PSI ® 28 DAYS C. GROUT: 1. STRENGTH: 1500 PSI ® 7 DAYS AND 2500 PSI @ 28 DAYS 2. CONCRETE BLOCK MASONRY UNITS SHALL BE DRY AND CLEAN BEFORE GROUTING OPERATION. 3. LOWER 3 COURSES ARE TO BE ALLOWED TO CURE FOR 3 FULL DAYS AFTER GROUTING PRIOR TO PLACING OR SELLING ANY FURTHER BLOCK COURSE THEREON. ENGINEER'S.. STATEMENT, I HEREBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS COMPLY WITH THE CITY OF BAKERSFIELD ORDINANCES, STANDARDS AND DESIGN CRITERIA, AND THAT THEY INCLUDE ALL IMPROVEMENTS OF THE ADVISORY AGENCY OR OTHER REVIEW BOARD. I AM RESPONSIBLE FOR ALL CALCULATIONS AND DRAWINGS ON THESE PLANS, AND ANY ERRORS, OMISSIONS OR VIOLATION OF THOSE ORDINANCES, STANDARD, AND DESIGN CRITERIA SHALL BE CORRECTED DURING CONSTRUCTION. REVIEWED BY: APPROVED 13 f zda)/,/ 3 -q -d7 aTRAFFIC ENGINEER DATE PUBLIC WORKS DIRECTOR S2 D DATE PUBLIC WORKS DIRECTOR -CITY OF BAKERSFIELD DATE RAUL M. ROJAS, R,C.E. 39880- EXP. 12-31-07 BEMIM EXCAVATING CALL • ETSA 1-800-227-2800 (--\NEER\ 00 JOB NO.: o mJ�2 00 S rn o W FILE NAME: Oa > V Z .a o���Nooa316 z z � ^ Y x O W .- O AS SHOWN � O � O c0 Q 0 00 Li U CK z Ir- af mw m W _ z z _w W U �R0 CK O m r o t� > e. O 0� w e a o PLOT DATE: 00 JOB NO.: rn o W FILE NAME: Qof I LL z O 00� O I 060026 -01 -COV -WALL SCALE: z z � ^ Y x O W .- O AS SHOWN � O � O c0 Q 0 1 OF W W M (n m �5 L U 0 V C o I m z w x �i�� a < a V o PLOT DATE: 01/19/07 JOB NO.: W FILE NAME: 060026 -01 -COV -WALL SCALE: AS SHOWN Z 1 OF �5 L 0 V C o < 0 - in LL, LLJ JW z 0 M 0 W W �aM �.Ycc LLJo i" Zar. Q0> W cc M PLOT DATE: 01/19/07 JOB NO.: 06uO26 FILE NAME: 060026 -01 -COV -WALL SCALE: AS SHOWN SHEET NO.: 1 OF }rte- 0 7� 00 co n w 4 z :DW m W J Z Z J W i- W U U z0 � n OD O � W O O W a d a o o rn00 O Q� o O I O U Z U <D 0 O X O � C) O r,) L, coOf O W m W 6� (n m L 3 U LLJ2 C U i m 0 W m cu m a Z Ld d 0 � l p z � � o O a U c O OC a o m Q p W04 U.4' F - LULU Q CG t - W `j C�,� Uv /A ' CC o�� F-m� r7DATE: 01/19/07 JOB NO.: 060026 FILE NAME: 060026-02-CALLOWAY-WALL SCALE: HORIZ. 1"=40' VERT. 1"=4' SHEET NO.: 2 OF REVISION Q APPROVED BY: 3KAN, : 51;L of lS` MATTHEW J. BARNES DATE RCE NO.: 79145 ef- S 4AAN P. SHAW DATE RCE NO.: 32178 410 mo 390 OF AK RSFI D ",TRACT,NO.* 64''19 PHAS NO. 1 GALLOWAY BLOCK WALL - 17+00 _ _ 18+0 — — 19+00_ _ _ 20 00 BLOCK WALL PER SHEET 2 OF APPROVED PLANS CALLOWAY DRIVE PHASE 2 WALL SEPARATE F 10+00"" 11+00 1 9`� OGS' FG BLOCK WALL ALIGNMENT 1 AT EAST FACE OF WALL 1 1 RETENTION BASIN 1 12+00 N 13+00 REVISED SECTION \\\\\\\\\ k. \m -0 09 40' 10+00 11+00 12+00 13+00 BENCHMARK &TOP OF CONCRETE MONUMENT AT THE INTERSECTION OF SNOW ROAD AND QUAIL CREEK ROAD, ALSO THE NORTH 1/4 CORNER OF SECTION 8 29/27 ELEVATION = 401.06' U.S.G.S. DATUM PER K.C.S.F.B. 1152, PG. 22 AND TR. 5909 STREET PLANS BASIS OF BEARING THE BEARING OF N00°52'25.7" E SHOWN FOR THE WEST LINE OF THE SOUTHWEST 1/4 OF SECTION 5, TOWNSHIP 29 SOUTH, RANGE 27 EAST, MOUNT DIABLO BASE & MERIDIAN, IN THE CITY OF BAKERSFIELD, COUNTY OF KERN, STATE OF CALIFORNIA AS SHOWN ON THE SURVEY INVESTIGATION MAP 7-1, BOOK 6, PAGE 50, WAS USED AS THE BASIS OF BEARINGS SHOWN ON THIS MAP. NOTE TO OWNER AND CONTRACTOR THIS PLAN HAS BEEN PREPARED WITH THE INTENT THAT QUAD KNOPF WILL BE PERFORMING THE CONSTRUCTION STAKING FOR THE COMPLETE PROJECT. IF, HOWEVER ANOTHER ENGINEERING AND/OR SURVEYING FIRM SHOULD BE EMPLOYED TO USE THESE PLANS FOR THE PURPOSE OF CONSTRUCTION STAKING, NOTICE IS HEREBY GIVEN THAT THE FIRM OF QUAD KNOPF, INC. WILL NOT ASSUME ANY RESPONSIBILITY FOR ERRORS OR OMISSIONS, IF ANY, WHICH MIGHT OCCUR AND WHICH COULD HAVE BEEN AVOIDED, CORRECTED OR MITIGATED IF QUAD KNOPF HAD PERFORMED THE STAKING WORK. ENGINEER'S STATEMENT I HEREBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS COMPLY WITH THE CITY OF BAKERSFIELD ORDINANCES, STANDARDS AND DESIGN CRITERIA, AND THAT THEY INCLUDE ALL IMPROVEMENTS OF THE ADVISORY AGENCY OR OTHER REVIEW BOARD. I AM RESPONSIBLE FOR ALL CALCULATIONS AND DRAWINGS ON THESE PLANS, AND ANY ERRORS, OMISSIONS OR VIOLATION OF THOSE ORDINANCES, STANDARD, AND DESIGN CRITERIA SHALL BE CORRECTED DURING CONSTRUCTION. m 390 380 14+00 TOP OF FOOTING: 396.50—FT VILAN11 Y mRr NOT TO SCALE CMU RETAINING WALL NOTES: 1. DESIGN IS PER CALIFORNIA BUILDING CODE (LATEST EDITIONS AND CITY OF BAKERSFIELD PUBLIC WORKS AND BUILDING DEPARTMENT REQUIREMENTS. DESIGN PER ATTACHED CALCULATIONS. MASONRY f'm=1,500 PSI (SPECIAL INSPECTION REQUIRED). 2. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60. A. REINFORCEMENT SPLICES SHALL BE AS SHOWN ON DRAWINGS AND SHALL BE 60 BAR DIAMETERS MINIMUM U.N.O. STAGGER ALL ADJACENT HORIZONTAL SPLICE POINTS 6 FEET MINIMUM. ALL LAP SPLICES SHALL BE WIRE TIED BOTH ENDS. ALL REINFORCING SHALL BE SECURELY HELD IN THE PROPER PLACE, BEFORE AND DURING GROUTING. 3. FOUNDATION CONCRETE SHALL ATTAIN A 28 DAY COMPRESSIVE STRENGTH OF 2,500 P.S.I. ® 28 DAYS. DESIGN BASED ON 2,500 P.S.I. (SPECIAL INSP. NOT REQ' D) 4. CONTRACTOR SHALL OVEREXCAVATE A MINIMUM OF 1—FOOT BELOW THE FOOTING AND BACKFILL AND COMPACT TO 90% RELATIVE COMPACTION OR PER THE PROJECT SOILS REPORT, DATED DECEMBER 12, 2013 BY KRAZAN AND ASSOCIATES, INC., WHICHEVER IS GREATER. ALL SOILS TESTING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL COMPLY WITH THE CITY OF BAKERSFIELD PUBLIC WORKS DEPARTMENT AND BUILDING DEPARTMENT. CONTRACTOR SHALL NOT POUR THE FOOTING UNTIL ALL COMPACTION TESTING HAS BEEN APPROVED BY THE CITY OF BAKERSFIELD PUBLIC WORKS AND BUILDING INSPECTORS. 5. CLEAR SPACING FOR REINFORCING SHALL BE 3" UNLESS OTHERWISE STATED ON THESE PLANS. 6. CONCRETE MASONRY UNITS SHALL CONFORM TO THE REQUIREMENTS LISTED IN THE LATEST EDITION OF THE CALIFORNIA BUILDING CODE. A. GROUT SHALL ATTAIN A MIN. 28 DAY COMPRESSIVE STRENGTH OF 3,000 P.S.I. AND COMPLY WITH ASTM C476. B. MORTAR SHALL CONFORM TO C.B.C. AND ASTM C270 TYPE S. MIN. 28 DAY COMP. STRENGTH SHALL BE 1,800 P.S.I., MIN. C. ALL MASONRY UNITS SHALL BE ASTM C90 GRADE N (I OR II), AND SHALL BE MADE WITH LIGHTWEIGHT AGGREGATE. MASONRY f'm=1,500 PSI MIN. UNLESS OTHERWISE NOTED ON THE PLANS. D. TYPE II MASONRY UNITS, IF USED, SHALL NOT BE MOIST, AND SHALL BE AGED SUFFICIENTLY TO ACHIEVE CLIMATIC BALANCE. E. SET ALL MASONRY UNITS PLUMB, TRUE TO LINE, AND LEVEL U.N.O. ON THE DRAWINGS. LAY UNITS IN FULL HEAD AND BED JOINTS OF 4 ' THICKNESS. STRIKE OFF EXCESS MORTAR FLUSH WITH FACE. FOR ALL EXPOSED JOINTS, WHEN THUMBPRINT HARD, TOOL TO OBTAIN A DENSE, UNIFORM CONCAVE JOINT. CLEAN MORTAR FINS PROJECTING MORE THAN ONE—HALF INCH FROM INSIDE CORES, AND REMOVE DROPPINGS FROM BOTTOM OF CELLS PRIOR TO GROUTING. F. GROUT WALLS ONLY AFTER MORTAR HAS CURED 24 HOURS. WALLS SHALL BE GROUTED IN 4'-0" MAXIMUM VERTICAL LIFTS. ALL WALLS SHALL BE GROUTED SOLID (FILL ALL CELLS SOLIDLY) U.N.O. ON DRAWINGS. G. ALL GROUT SHALL BE VIBRATED INTO PLACE WITH A PENCIL TIP VIBRATOR. H. KEY GROUT POURS BY HOLDING TOP OF GROUT 1Yi' BELOW TOP OF BLOCK. DO NOT STOP GROUT LIFT AT REINFORCED BOND BEAMS. 7. VERTICAL CONTROL JOINTS SHALL BE AT PILASTERS. 8. COMPACT BACKFILL TO 90% RELATIVE COMPACTION OR GEOTECHNICAL ENGINEER'S RECOMMENDATION, WHICHEVER IS GREATER. HAND COMPACT BACKFILL IN MAXIMUM EIGHT (8) INCH LIFTS A DISTANCE EQUAL TO RETAINED HEIGHT BACK FROM FACE OF WALL. RETAINED UNDISTURBED NATIVE SOILS NEED NOT BE COMPACTED. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TESTING OF COMPACTED FILL. 9. WHERE RETAINED GRADE IS 2—FEET OR GREATER, CONTRACTOR SHALL PROVIDE 12" WIDE DRAIN ROCK WRAPPED IN FILTER FABRIC FOR WEEP HOLES AS INDICATED ON THE SECTION VIEW. TOP OF DRAIN ROCK SHALL BE A MIN. OF 12" BELOW FINISHED GRADE. 10. ANY AND ALL TESTING REQUIRED BY THE CITY OF BAKERSFIELD SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. NOTE: SEE APPROVED WALL PLANS FOR TRACT 6419 PHASE 1 FOR GENERAL NOTES. MORTAR CAP- 8"x8"x16" CMU BLOCK WALL CL Q i e ��] a• S d 'd'' - a Q( , a .4 .d 'd a • A ° g .y d d O! — I A - ^ e �J -"O - d _ a - - 4 0 .. c �Q_ Ld ° a n d a I TOP OF FOOTING: 392.50—FT Q:) �. A d' 4 d REINFORCEMENT PER WALL _ 44 PREVIOUSLY APPROVED WALL e ' e " .d 2'-8" ° . ° d d' TYP. SECTION (SEPARATE PLANS) b a. -1 d e A. 4 d U ce d ve - ° O 4 9 01—p2'—O.. (U� V .d .eQe e 9 ° e d TYP TYP LANDSCAPE SIDE d d REINFORCEMENT PER 4—#4 VERT. BARS c #4 TIES ® 24" O.C. a Q 19 4 ' P 'a" e; a WALL SECTION SHOWN \a .' d. d- ON THESE PLANS HORIZONTAL REINEFORCEMENT J o z -"- ' - ' ¢: - _ 4 . ` - ° A d a'. a.e. d o- 0.2" DEEP CAUL PER WALL SECTION KING BACKER ROD ° ° d • a c .' Q d3 ° . a .. ® EXPANSION JOINT SUMP d o —3" �. .a. d q .. ° d a NOTE: MIN. (TYP.) - a . e 4 • 4 d. . v: v 4 .° ° a Q..- d. e EXPANSION JOINTS MUST EXTEND VERTICALLY AT ALL PILASTERS. JOINT MUST ° ° ` Q' d a 3" J.D BEND (hi'P,) NOT CONTAIN ANY INCOMPRESSIBLE MATERIAL (EX. GROUT OR MORTAR) d . e d d -4 a ° ¢ °_ a a nd ° EXTEND CAULKING 6" BELOW GRADE #4 STD. STIRRUPS , " a ` ? e4e. .e -4 ° ® 16" O.C. (TYP.) a e . 4 ?d e e d4 d PILASTER DETAIL STEP FOOTING DETAIL Q a LAP SPLICE NOT TO SCALE NOT TO SCALE 72ab = 3'-0" (TYP.) CALLOWAY TRACT 6419 LANDSCAPE 9 a I1 ... PHASE 1 I I I" II1y LANDSCAPE FlNISHED GRADE t. �/'i30" LAP SPLICE #4 HORIZONTAL HAW O 24" O.C. OYP•) 12" WOE 7 Ap Hall r 3' INSIDE.O `BEND° d 1 44 0 16' O.C. R' 8 BOTH WAYS ,1'-6",'' 4. —_— — —_ — — — OVE M(CAVATE I -FOOT MIN. AND b — — — — — — — — — COMPACTION OR PER GEOTECHNICAL — — — REPORT. WHICHEVER 1S GREATER I'-2" X-4" 4'-6' RETAINING WALL SECTION NOT TO SCALE r w z 0 a a, - (3) 0 m N U <� I V) K LU z 0 z ^ D W LLJ z U N W or Ld N m o Ld 00 Q w o 0 x w Y Lo U) m H Li. j U l.i< Z W U U Z co (YLJ.! a o oLL a0 z TOT Z Y �J r i a ��- Cfl a � Q d U n z 0 m r m Q ca x m J EDuj F- U >z a U p L ® a rr U uj W s m Lo4 Q o QROFESS/p�, J. F1p y w r NO. 79145 s lF OF, CAl\FOR L0 r w U N W zafW <,z Ld m— cD �z W Ld U z W a0 ca m � o W 0 o- Q o Lj uj o0 o w z 0 a a, - (3) 0 m N U Z U (O (D d K LU z 0 z ^ D W LLJ J o Ld N U N W or Ld N m o Ld 00 Q w o Q t j 3 x w Y Lo U) m H Li. j U l.i< Z W U U Z co (YLJ.! a o oLL a0 z TOT Z Y �J r i a ��- Cfl a � Q d U n m r m Q ca x m J EDuj F- U >z a U p L ® i d z 0 z LU z LLJ J LLI U 1 LL o *' J 0 7 wa w co (YLJ.! N o L a0 z TOT z — �J r LL i Z o arn0 M ��- Cfl a � Q d U n 0 Z zoo LL! 00 W MOJ cc Q J o U. F- U PLOT MACH 24, 2015 JOB NO.: 130190.01 FILE NAME: 30190 -RETAINING WALL-RCALLOWA SCALE: AS SHOWN SHEET NO.: 2AR OF 3