Loading...
HomeMy WebLinkAbout1.2-6663 Ph 1 & 2 RevLEGEND: OF SHEETS ABBREVIATIONS CL CENTERLINE INV INVERT SD STORM DRAIN MH MANHOLE CB CATCH BASIN JB JUNCTION BOX SMH SEWER MANHOLE SCO SEWER CLEANOUT SDMH STORM DRAIN MANHOLE EXIST EXISTING ELEV ELEVATION R/W RIGHT OF WAY r 0•M. 363.22 TOP OF MANHOLE/TOP OF CLEANOUT ELEVATION ■■�■■■�■■�■■� TRACT BOUNDARY s CONSTRUCT SEWER PER CITY STANDARDS 0 CONSTRUCT SEWER MANHOLE TYPE "A" PER C.O.B. STD. S-7. 0 CONSTRUCT SEWER CLEANOUT PER C.O.B. STD. S-20. CONSTRUCT STORM DRAIN PER CITY STANDARDS 0 CONSTRUCT STORM DRAIN MANHOLE TYPE "A" PER C.O.B. STD. S-7. oir CONSTRUCT CATCH BASIN TYPE "A" PER C.O.B. STD. S-12. W WATER LINE SHOWN AT LOCATIONS OF PIPE CROSSINGS q MULTIPLE UTILITY TRENCH q SEWER MAIN 4' R 5' TVP. I STAMP AN "S" 5, v �3 IN THE CURB TYP. m 3 FACE ABOVE SEWER LETERAL I 60" 7' MAX. °o TVP. 1$ MIN. 4" LATERAL (TYP) \ ON DEEP SEWER, SLOPE LATERALS �\ TO LOT LINE SO THAT THE END OF LATERAL IS WITHIN REQUIRED TOLERANCE. FINISHED STREET GRADE 36�" TYP. q R 4' WATERLINE �a 3 0 1% MIN. ---�� 4" LATERAL (TYP) SET LATERAL PROVIDING PROPER CLEARANCE UNDER WATERLINE AND UTILITY TRENCHES NOTE: CONTRACTOR TO VERIFY THAT WATER DETAIL MAIN AND SEWER LATERAL CROSSINGS TYPICAL SEWER LATERAL INSTALLATION ARE IN CONFORMANCE WITH CALIFORNIA HEALTH CODE REQUIREMENTS. 7' MAX. CITY OF BAKERSFIELD KERN COUNTY CALIFORNIA SEWER AND STORM DRAIN PLANS FOR VESTING TENTATIVE TRACT NO. 6663 PHASES 1 & 2 E,Vs7 G COMMERCIAL an - KLY MAN SCALE: 1" = 200' ODENOTES SHEET NUMBER Q VIUINI IT MAF NO SCALE INDEX OF SHEETS No7 " #'HASl� l S N 1" 8� CvWSTRUGT,r�l� 1�1 RS7 • SHEET TITLE o�(�-�r> RL-FER -M :C#fie 1A por UMMARY OF IMPROVEMENT A01 . COVER SHEET M �E121 N� F �'7 SE MPROVEMENTS A 2. NOTES & SPECIFICATIONS 6" SE R LINE 8" SEI- WE LINE 26 1639 LF LF 3lZ 3. TULIA LANE & CROOM LANE 10 SEWER NE LATERALS 1354 LF m 4" 3659 LF 4R 4. BANGOR PLACE STANbARD MAN LE 16 EA ,- SEWER CLEAN OU 2 EA ( 5IZ Q 5. SUNCHASE DRIVE GR 6. SHANAGOLDEN STREET & NAVAN PLACE ST RM DRAT IMPR V M Ta TOTAL 'TEZ 7. SUMP & TEMPORARY SUMP DETAILS 18" STO DRAIN LINE 2249 LF 2 STOR RAIN MANHOLES 8 EA CAjZH BASINS 1 EA TLET STRUCTURES EA a AfPlzOur:v 0 i2oGik-(Z A. McINTOSE-I R,c,E 333zZ DATE A fIptzO\ter� RY DAN►E't_ F'.c�prL1-A �.c,(=; G7oa8 ��E �k FOR SHALLOW INSTALLATION OF SEWER LATERALS FROM SHALLOW SEWER MAINS, THE SEWER LATERALS MUST CROSS OVER THE WATER OR UTILITY TRENCH. THESE INSTALLATIONS MUST RECEIVE SPECIAL TREATMENT FOR LATERALS WHEN CROSSING OVER THE WATERMAIN. ; A SEWER LATERAL CROSSING ABOVE A WATER MAIN SHALL BE CONSTRUCTED OF A -� CONTINUOUS 20' SECTION OF CLASS 200 (DR 14 PER AWWA C900) PLASTIC PIPE OR EQUIVALENT, CENTERED ON THE PIPE BEING CROSSED. LO kFai:6 Z 7a SmF-ET !A AOR I���Vb�b QuAn�'T!'iy -rAa3c-� NOTE: 1. PRIOR TO THE START OF ANY PHASE OF CONSTRUCTION, THE CITY CONSTRUCTION INSPECTION DEPARTMENT SHALL BE GIVEN 24 HOURS NOTICE. TELEPHONE 326-3049 2. ALL MATERIALS SUPPLIED FOR THIS PROJECT WILL REQUIRE A CERTIFICATE OF COMPLIANCE STATING THAT THE REQUIREMENTS & STANDARDS SET FORTH BY THE CITY OF BAKERSFIELD HAVE BEEN MET. 3. NO CITY INSPECTIONS WILL BE GIVEN FOR THE WORK IN THIS AREA UNTIL A STREET PERMIT WITH APPROPRIATE SECURITY AND INSURANCE HAS BEEN OBTAINED. ENGINEER'S STATEMENT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECTION AND TO THE BEST OF MY KNOWLEDGE AND BELIEF COMPLY WITH CITY OF BAKERSFIELD ORDINANCES, STANDARDS, AND DESIGN CRITERIA AND INCLUDE ALL IMPROVEMENT REQUIREMENTS OF THE ADVISORY AGENCY OR OTHER REVIEW BOARD. I AM RESPONSIBLE FOR ALL CALCULATIONS AND DRAWINGS ON THESE PLANS AND ANY ERRORS, OMISSIONS, OR VIOLATIONS OF THOSE ORDINANCES, STANDARDS SAND DESIGN CRITERIA SHALL BE EXP. 6-30-16 IN ACCORDANCE WITH THE CONDITIONS OF THE VESTING TENTATIVE MAP, THE IMPROVEMENT PLANS HAVE BEEN REVIEWED BY THE CITY OF BAKERSFIELD PUBLIC WORKS DEPARTMENT. ALL IMPROVEMENTS HEREIN ARE PUBLIC AND ARE TO BE PUBLICLY MAINTAINED. APPROVED BY: NICOLA FIDLER, PUBLIC WORKS DIRECTOR DATE R.C.E. NO. 61069 EXP. 12-31-16 REVIEWED BY: ASSISTANT PUBLIC WORKS DIRECTOR BASIS OF BEARINGS: THE BEARING OF N88'57'42"E, SHOWN FOR THE NORTH LINE OF THE NORTHEAST QUARTER OF SEC. 28, T.30S., R.27E. M.D.M., RECORD OF SURVEY NO. 3415, R.S. BOOK 29, PAGE 100 IN THE OFFICE OF THE KERN COUNTY SURVEYOR, WAS TAKEN AS THE BASIS OF BEARINGS SHOWN HEREON. BENCHMARK USED: TOP OF CONCRETE MONUMENT IN LAMPHOLE AT THE CENTERLINE INTERSECTION OF RELIANCE DRIVE AND FIREBAUGH STREET. ELEVATION = 356.735' (U.S.G.S. DATUM) PER TRACT NO. 5845 PHASES A -D, MON. ELEV. MAP LEGAL DESCRIPTION: THE NORTH HALF OF THE NORTHEAST QUARTER OF SECTION 28, TOWNSHIP 30 SOUTH, RANGE 27 EAST, M.D.M., CITY OF BAKERSFIELD, COUNTY OF KERN, STATE OF CALIFORNIA. Know what's below. 0111 before you dig. mN m 4 2 cn Q Z O w� � N y o� q STANDARD NOTES 1. GENERAL CONTRACTOR WILL FURNISH ALL MATERIALS, TOOLS, LABOR, EQUIPMENT AND SUPERVISION NECESSARY TO COMPLETE INSTALLATION. UNDERGROUND SERVICE ALERT (USA) SHALL BE NOTIFIED AT LEAST 2 WORKING DAYS BEFORE CONSTRUCTION. TELEPHONE 1-800-227-2600. CONTRACTOR TO CALL FOR USA LOCATE AND POTHOLE ALL MARKED UTILITIES THAT CROSS OR ARE WITHIN 5' HORIZONTAL DISTANCE OF SEWER AND STORM DRAIN LINES. VERTICAL AND HORIZONTAL LOCATION SHALL BE ASCERTAINED BY THE CONTRACTOR AHEAD OF ANY EXCAVATIONS TO VERIFY THAT THE PROPOSED DESIGN DOES NOT CONFLICT WITH ANY UTILITIES. IN THE EVENT A CONFLICT EXISTS THE ENGINEER SHALL BE NOTIFIED IN ORDER TO REDESIGN THE ALIGNMENT. IF RELOCATION OF EXISTING UTILITIES IS DEEMED NECESSARY THE CONTRACTOR SHALL BE COMPENSATED FOR INSTRUCTED RELOCATION. IF REDESIGN OF THE ALIGNMENT REQUIRES ADDITIONAL FITTINGS, PIPE OR EXCAVATION THE CONTRACTOR SHALL BE COMPENSATED FOR REVISION. IN THE EVENT A UTILITY IS DAMAGED THE CONTRACTOR SHALL BE WHOLLY RESPONSIBLE FOR ITS REPAIR. CONTRACTOR SHALL VERIFY LOCATIONS AND ELEVATIONS OF EXISTING SEWER LINES THAT THE NEW SYSTEM TIES INTO PRIOR TO TRENCHING. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER SO THAT ANY NECESSARY ADJUSTMENTS MAY BE MADE UTILITIES SHALL BE THOROUGHLY RESEARCHED AND LOCATED BY CONTRACTOR PRIOR TO TRENCHING. CROSSING UTILITIES SHALL BE DAYLIGHTED AND CHECKED FOR GRADE, BY CONTRACTOR PRIOR TO TRENCHING. ALL EXISTING IMPROVEMENTS, (CURB, GUTTER, SIDEWALK, CROSS GUTTER, FENCES, ETC.) THAT ARE REMOVED, DAMAGED OR UNDERCUT SHALL BE REPAIRED OR REPLACED AS DIRECTED BY THE CITY ENGINEER. ALL EXISTING PAVING AND SURFACING REMOVED, DAMAGED OR UNDERCUT SHALL BE REPLACED IN ACCORDANCE WITH THE CITY OF BAKERSFIELD STANDARD DRAWING ST -6, EXCEPT AS NOTED ON PLANS. STAMP AN "S' INTO THE CURB FACE OVER EACH SEWER LATERAL AN OPEN STREET PERMIT SHALL BE OBTAINED FROM THE CITY OF BAKERSFIELD PUBLIC WORKS DEPARTMENT FOR ANY WORK PERFORMED WITHIN EXISTING ACCEPTED STREET RIGHT- OF-WAY. UNLESS SECURED BY AN IMPROVENT AGREEMENT, APPROVED INSURANCE AND SECURITY BASED ON AN APPROVED ENGINEER'S ESTIMATE FOR THE WORK PERFORMED WITHIN THE RIGHT-OF-WAY SHALL BE POSTED PRIOR TO ISSUANCE OF THE PERMIT COMPACTION TESTS SHALL BE THE RESPONSIBUTY OF THE DEVELOPER/CONTRACTOR. THE NUMBER AND LOCATION OF REQUIRED TESTS SHALL BE DETERMINED BY THE CITY ENGINEER 2. STANDARD DETAILS THE FOLLOWING CITY OF BAKERSFIELD STANDARDS SHALL BE CONSIDERED PART OF THESE PLANS: D-11, D-14, D-16, D-18 SW -1, SW -2, SW -3, SW -4, SW -5, SW -6, SW -9, SW -11, ST -6, ST -22 3. VCP INSTALLATION MATERIALS : THE PIPE AND FITTINGS SHALL BE EXTRA STRENGTH VITRIFIED CLAY CONFORMING TO CURRENT ASTM SPECIFICATION C-700 AND SHALL BE INSTALLED IN CONFORMANCE WITH THE PROVISIONS OF SECTION 71 OF THE STANDARD SPECIFICATIONS OF THE STATE OF CALIFORNIA, DEPARTMENT OF TRANSPORTATION, CURRENT EDITION AND THE CURRENT ASTM SPECIFICATIONS C-12. JOINTS : THE PIPE AND FITTINGS SHALL HAVE A SOCKET END AND A SPIGOT END WITH COMPRESSION JOINTS CONFORMING WITH THE CURRENT ASTM SPECIFICATION C-425. THE PIPE AND FITTINGS FOR 6% 8", 10", AND 12" SANITARY SEWER MAINS MAY BE PLAIN -END WITH COMPRESSION COUPLINGS CONFORMING WITH THE CURRENT ASTM SPECIFICATION C-425. EXCEPTING THAT A STAINLESS STEEL SHEAR RING AS MANUFACTURED BY MISSION CLAY PRODUCTS CORPORATION FOR THEIR 'MAINUNE" BANDSEAL COMPRESSION COUPLING, OR APPROVED EQUAL, SHALL BE REQUIRED. THE PIPE AND FITTINGS FOR PRIVATE SANITARY SEWER HOUSE OR BUILDING LATERALS MAY BE PLAIN -END WITH COMPRESSION COUPLINGS CONFORMING WITH THE CURRENT ASTM SPECIFICATION C-425. (STAINLESS STEEL SHEAR RINGS ARE NOT REQUIRED) 4. ABS PIPE INSTALLATION MATERIALS : PIPE AND FITTINGS SHALL MEET THE REQUIREMENTS OF THE CURRENT ASTM SPECIFICATIONS D-2680 AND D-2751. PIPE AND FITTINGS SHALL BE HOMOGENEOUS THROUGH OUT AND FREE FROM CRACKS, HOLES, FOREIGN INCLUSIONS OR OTHER INJURIOUS DEFECTS. FITTINGS SHALL BE INJECTION MOLDED AND SHALL BE INSTALLED IN LINE ON NEW PIPELINES; CUT -IN FITTINGS ARE NOT PERMITTED. JOINTS : USE ONLY SOLVENT WELDED JOINTS. THE ASSEMBLY OF JOINTS SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE ABS PIPE CONNECTS TO VCP, USE COUPLINGS APPROVED BY THE CITY OF BAKERSFIELD. INSTALLATION : PIPE AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT ASTM SPECIFICATION D-2321. ONLY CLASS 1, II, AND III EMBEDMENT MATERIALS WILL BE CONSIDERED SUITABLE. 5. PVC PIPE INSTALLATION MATERIALS : PIPE AND FITTINGS SHALL MEET THE REQUIREMENTS OF THE CURRENT ASTM SPECIFICATION D-3034 FOR SDR35. PIPE AND FITTINGS SHALL BE HOMOGENEOUS THROUGHOUT AND FREE FROM CRACKS, HOLES, FOREIGN INCLUSIONS OR OTHER INJURIOUS DEFECTS. FITTINGS SHALL BE INJECTION MOLDED AND SHALL BE INSTALLED IN UNE ON NEW PIPELINES; CUT -IN FITTINGS ARE NOT PERMITTED. JOINTS : USE ONLY ELASTOMERIC GASKET JOINTS. THE ASSEMBLY OF JOINTS SHALL BE IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS WHERE PVC PIPE CONNECTS TO VCP PIPE, USE COUPLINGS APPROVED BY THE CITY OF BAKERSFIELD. INSTALLATION : PIPE AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT ASTM SPECIFICATION D-2321. ONLY CLASS 1, 11, AND III EMBEDMENT MATERIALS WILL BE CONSIDERED SUITABLE. 6, REINFORCED CONCRETE PIPE WITH PVC LINING. REINFORCED CONCRETE PIPE WITH PVC LINING SHALL MEET THE FOLLOWING REQUIREMENTS: I.A. MATERIALS. REINFORCED CONCRETE PIPE (RCP) SHALL BE EITHER CLASS IV OR CLASS V WITH WALLS "B" OR V. RCP SHALL MEET ASTM C 76 FOR STRENGTH, ASTM C 361 OR AWWA C302 EXCEPT TEST PRESSURE SHALL BE 5 PSI FOR RUBBER GASKETS, AND LINER TESTS IN ACCORDANCE WITH THE FOLLOWING PARAGRAPHS. PIPE SHALL BE WET CAST, VIBRATED AND STEAM OR WATER CURED. JOINTS SHALL BE BELL AND SPIGOT DESIGN WITH A CONTAINED 0 -RING GASKET. PVC LINER SHALL BE CAST INTO THE WALL OF THE RCP AND SHALL COVER 36W OF THE PIPE ALL WORK FOR AND IN CONNECTION WITH THE INSTALLATION OF THE LINING IN CONCRETE PIPE AND FIELD SEALING AND WELDING OF JOINTS SHALL BE DONE IN STRICT CONFORMITY WITH ALL APPLICABLE SPECIFICATIONS, INSTRUCTIONS AND RECOMMENDATIONS OF THE LINING MANUFACTURER. LINER SHALL MEET THE FOLLOWING REQUIREMENTS. 1.B. PHYSICAL PROPERTIES OF LINER. ALL PLASTIC LINER PLATE SHEETS, WELDING STRIPS AND OTHER ACCESSORY ITEMS, SHALL HAVE THE FOLLOWING PHYSICAL PROPERTIES WHEN TESTED AT 77F t5 (251C t3 ). PROPERTY INITIAL (PAR, TENSILE STRENGTH 2200 PSI MIN. 2100 PSI MIN. (15 MPA MIN.) (14.5 MPA MIN.) ELONGATION AT BREAK 200% MIN. 200% MIN. SHORE DUROMETER, TYPE D 1 -SEC. 50-60 f5 (WITH RESPECT TO INITIAL TEST RESULT) 10 -SEC. 35-50 t5 WEIGHT CHANGE f1.5 TENSILE SPECIMENS SHALL BE PREPARED AND TESTED IN ACCORDANCE WITH ASTM D412 USING DIE B. WEIGHT CHANGE SPECIMENS SHALL BE 1 -INCH (25 -MM) BY 3 -INCH (75 -MM) SAMPLES. SPECIMENS FOR TESTING OF INITIAL PHYSICAL PROPERTIES MAY BE TAKEN FROM LINER PLATE SHEET AND WELDING STRIP AT ANY TIME PRIOR TO FINAL ACCEPTANCE OF THE WORK. LINER PLATE LOCKING EXTENSIONS EMBEDDED IN CONCRETE SHALL WITHSTAND A TEST PULL OF AT LEAST 100 POUNDS PER LINEAR INCH (1800 KG/M), APPLIED PERPENDICULARLY TO THE CONCRETE SURFACE FOR A PERIOD OF ONE MINUTE, WITHOUT RUPTURE OF THE LOCKING EXTENSIONS OR WITHDRAWAL FROM EMBEDMENT. THIS TEST SHALL BE MADE AT A TEMPERATURE OF 70' - 80' F(21' - 27' C) INCLUSIVE ALL PLASTIC LINER PLATE SHEETS, INCLUDING LOCKING EXTENSIONS, ALL JOINT, CORNER AND WELDING STRIPS SHALL BE FREE OF CRACKS, CLEAVAGES OR OTHER DEFECTS ADVERSELY AFFECTING THE PROTECTIVE CHARACTERISTICS OF THE MATERIAL THE ENGINEER MAY AUTHORIZE THE REPAIR OF SUCH DEFECTS BY APPROVED METHODS. THE LINING SHALL HAVE GOOD IMPACT RESISTANCE, SHALL BE FLEXIBLE AND SHALL HAVE AN ELONGATION SUFFICIENT TO BRIDGE UP TO 1/4 -INCH (6 MM) SETTLING CRACKS, WHICH MAY OCCUR IN THE PIPE OR IN THE JOINT AFTER INSTALLATIONS, WITHOUT DAMAGE TO THE LINING. 1.C. CHEMICAL RESISTANCE OF LINER.* AFTER CONDITIONING TO CONSTANT WEIGHT AT 110 F(43 C), TENSILE SPECIMENS AND WEIGHT CHANGE SPECIMENS SHALL BE EXPOSED TO THE FOLLOWING SOLUTIONS FOR A PERIOD OF 112 DAYS AT 77' F t5 (25' C t3 ). AT 28 -DAY INTERVALS, TENSILE SPECIMENS AND WEIGHT CHANGE SPECIMENS SHALL BE REMOVED FROM EACH OF THE CHEMICAL SOLUTIONS AND TESTED IN ACCORDANCE WITH SECTION 7-2.03(1.B) PARA. 2 ABOVE. IF ANY SPECIMEN FAILS TO MEET THE 112 -DAY REQUIREMENTS BEFORE COMPLETION OF THE 112 -DAY EXPOSURE, THE MATERIAL WILL BE SUBJECT TO REJECTION. CHEMICAL SOLUTION SULFURIC ACID SODIUM HYDROXIDE AMMONIUM HYDROXIDE NITRIC ACID FERRIC CHLORIDE 1% SOAP DETERGENT (LINEAR ALKYL BENZYL SULFONATE OR LAS BACTERIOLOGICAL CONCENTRATION 20%** 5% 5%** 1%** 1% 0.1% 0.1% BOD NOT LESS THAN 700 PPM *THIS IS TO BE USED AS A PRE -QUALIFICATION TEST AND WHEN MATERIAL FORMULATIONS ARE CHANGED. **VOLUMETRIC PERCENTAGES OF CONCENTRATED C.P. GRADE REAGENTS. I.D. DETAILS AND DIMENSIONS OF LINER SHEETS. LINER SHEETS SHALL BE A MINIMUM OF 0.065 INCH (1.65 MM) IN THICKNESS. LOCKING EXTENSIONS OF THE SAME MATERIAL AS THAT OF THE LINER SHALL BE INTEGRALLY EXTRUDED WITH THE SHEET. 1.E. INSTALLATION OF LINING. INSTALLATION OF THE LINING, INCLUDING PREHEATING OF SHEETS IN COLD WEATHER AND THE WELDING OF ALL JOINTS, SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE LINER MANUFACTURER. COVERAGE OF THE LINING SHALL NOT BE LESS THAN THE MINIMUM SHOWN ON THE PLANS. THE LINING SHALL BE INSTALLED WITH THE LOCKING EXTENSIONS RUNNING PARALLEL WITH THE LONGITUDINAL AXIS OF THE PIPE. THE LINING SHALL BE HELD SNUGLY IN PLACE AGAINST INNER FORMS. LOCKING EXTENSION SHALL TERMINATE NOT MORE THAN 1-1/2 INCHES (38 MM) FROM THE END OF THE INSIDE SURFACE OF THE PIPE SECTION. JOINT FLAPS WHEN USED SHALL EXTEND APPROXIMATELY 4 INCHES (100 MM) BEYOND THE END OF THE INSIDE SURFACE. CONCRETE POURED AGAINST LINING SHALL BE VIBRATED, SPADED OR COMPACTED IN A CAREFUL MANNER SO AS TO PROTECT THE LINING AND PRODUCE A DENSE, HOMOGENOUS CONCRETE, SECURELY ANCHORING THE LOCKING EXTENSIONS INTO THE CONCRETE. IN REMOVING FORMS. CARE SHOULD BE TAKEN TO PROTECT THE LINING FROM DAMAGE. SHARP INSTRUMENTS SHALL NOT BE USED TO PRY FORMS FROM LINED SURFACES. WHEN FORMS ARE REMOVED, ANY NAILS THAT REMAIN IN THE LINING MALL BE PULLED, WITHOUT TEARING THE LINING, AND THE RESULTING HOLES CLEARLY MARKED. ALL NAIL AND TIE HOLES AND ALL CUT, TORN AND SERIOUSLY ABRADED AREAS IN THE LINING SHALL BE PATCHED. PATCHES MADE ENTIRELY WITH WELDING STRIP SHALL BE FUSED TO THE LINER OVER THE ENTIRE PATCH AREA. LARGER PATCHES MAY CONSIST OF SMOOTH LINER SHEET APPLIED OVER THE DAMAGED AREA WITH ADHESIVE ALL EDGES MUST BE COVERED WITH WELDING STRIP FUSED TO THE PATCH AND THE SOUND LINING ADJOINING THE DAMAGED AREA. HOT JOINT COMPOUNDS, SUCH AS COAL TAR, SHALL NOT BE POURED OR APPLIED TO THE LINING. THE CONTRACTOR SHALL TAKE ALL NECESSARY MEASURES TO PREVENT DAMAGE TO INSTALLED LINING FROM EQUIPMENT AND MATERIALS USED IN OR TAKEN THROUGH THE WORK. 1.F APPLICATION TO CONCRETE PIPE - SPECIAL REQUIREMENTS. THE LINING SHALL BE SET FLUSH WITH THE INNER EDGE OF THE BELL OR SPIGOT END OF A PIPE SECTION AND SHALL EXTEND TO THE OPPOSITE END OR TO APPROXIMATELY 4 INCHES (100 MM) BEYOND THE OPPOSITE END DEPENDING UPON THE TYPE OF LINING JOINT TO BE MADE WITH THE ADJOINING CONCRETE PIPE. WHEREVER CONCRETE PIPE OR CAST -IN-PLACE STRUCTURES PROTECTED WITH LINING, JOIN STRUCTURES NOT SO LINED (SUCH AS BRICK STRUCTURES, CONCRETE PIPE OR CAST -IN-PLACE STRUCTURES WITH CLAY LINING OR CLAY PIPE), THE LINING SHALL BE EXTENDED OVER AND AROUND THE END OF THE PIPE AND BACK INTO THE STRUCTURE FOR NOT LESS THAN 4 INCHES (100 MM). THIS PROTECTING CAP MAY BE MOLDED OR FABRICATED FROM THE LINING MATERIAL BUT NEED NOT BE LOCKED INTO THE PIPE WHERE A PIPE LATERAL (NOT OF PLASTIC LINED CONCRETE) IS INSTALLED THROUGH LINED CONCRETE PIPE, THE SEAL BETWEEN THE LINED PORTION AND THE LATERAL SHALL BE PER THE MANUFACTURER'S RECOMMENDATIONS. LINED CONCRETE PIPE MAY BE CURED BY STANDARD CURING METHODS. CARE SHALL BE EXERCISED IN HANDLING, TRANSPORTING AND PLACING LINED PIPE TO PREVENT DAMAGE TO THE LINING. NO INTERIOR HOOKS OR SLINGS SHALL BE USED IN LIFTING PIPE. ALL HANDLING OPERATION SHALL BE DONE WITH AN EXTERIOR SUNG OR WITH A SUITABLE FORK LIFT. ON PIPE HAVING A 360' LINER COVERAGE, THE LONGITUDINAL EDGES OF THE SHEET SHALL BE BUTT WELDED. WHEN PIPE TUBES ARE FURNISHED. THESE ARE SHOP -WELDED JOINTS. NO PIPE WITH DAMAGED LINING WILL BE ACCEPTED UNTIL THE DAMAGE HAS BEEN REPAIRED TO THE SATISFACTION OF THE ENGINEER. 1.G. FIELD JOINTS IN LINING FOR CONCRETE PIPE THE JOINT BETWEEN SECTIONS OF LINED PIPE SHALL BE PREPARED IN THE FOLLOWING MANNER: IF REQUIRED, THE INSIDE JOINT SHALL BE FILLED AND CAREFULLY POINTED WITH CEMENT MORTAR IN SUCH A MANNER THAT THE MORTAR SHALL NOT, AT ANY POINT, EXTEND INTO THE PIPE BEYOND THE STRAIGHT LINE CONNECTING THE SURFACES OF THE ADJACENT PIPE SECTIONS. PIPE JOINTS MUST BE DRY BEFORE LINING JOINTS ARE MADE ALL MORTAR AND OTHER FOREIGN MATERIAL SHALL BE REMOVED FROM LINING SURFACES ADJACENT TO THE PIPE JOINT, LEAVING THEM CLEAN AND DRY. FIELD JOINTS IN THE LINING AT PIPE JOINTS MAY BE EITHER OF THE FOLLOWING DESCRIBED TYPES: TYPE P-1: THE JOINT SHALL BE MADE WITH A SEPARATE 4 -INCH (100 -MM) JOINT STRIP AND TWO WELDING STRIPS. THE 4 -INCH (100 -MM) JOINT STRIP SHALL BE CENTERED OVER THE JOINT, HEAT -SEALED TO THE LINING. THEN WELDED ALONG EACH EDGE TO ADJACENT LINER SHEETS WITH A 1 -INCH (25 -MM) WELD STRIP. THE 4 -INCH (100 -MM) JOINT STRIP SHALL LAP OVER EACH SHEET A MINIMUM OF 1/2 INCH (13 MM). TYPE P-2: THE JOINT SHALL BE MADE WITH A JOINT FLAP WITH LOCKING EXTENSIONS REMOVED AND EXTENDING APPROXIMATELY 4 INCHES (100 MM) BEYOND THE PIPE END. THE JOINT FLAP SHALL OVERLAP THE LINING IN THE ADJACENT PIPE SECTION A MINIMUM OF 1/2 INCH (13 MM) AND BE HEAT -SEALED IN PLACE PRIOR TO WELDING. THE FIELD JOINT SHALL BE COMPLETED BY WELDING THE FLAP TO THE LINING OF THE ADJACENT PIPE USING 1 -INCH (25 -MM) WELD STRIP. CARE SHALL BE TAKEN TO PROTECT THE FLAP FROM DAMAGE EXCESSIVE TENSION AND DISTORTION IN BENDING BACK THE FLAP TO EXPOSE THE PIPE JOINT DURING LAYING AND JOINT MORTARING SHALL BE AVOIDED. AT TEMPERATURES BELOW 50 F(10 C), HEATING OF THE LINER MAY BE REQUIRED TO AVOID DAMAGE. THE JOINT FLAP OR STRIP ON BEVELED PIPE SHALL BE TRIMMED TO A WIDTH (MEASURED FROM THE END OF THE SPIGOT) OF APPROXIMATELY 4 INCHES (100 MM) FOR THE ENTIRE CIRCUMFERENTIAL LENGTH OF THE LINING. ALL WELDING OF JOINTS IS TO BE IN STRICT CONFORMANCE WITH THE SPECIFICATIONS AND INSTRUCTIONS OF THE LINING MANUFACTURER. WELDING SHALL FUSE BOTH SHEETS AND WELD STRIP TOGETHER TO PROVIDE A CONTINUOUS JOINT EQUAL IN CORROSION RESISTANCE AND IMPERMEABILITY TO THE LINER PLATE. HOT-AIR WELDING TOOLS SHALL PROVIDE EFFLUENT AIR TO THE SHEETS TO BE JOINED AT A TEMPERATURE BETWEEN 500 AND 600 F (260 AND 316 C). WELDING TOOLS SHALL BE HELD APPROXIMATELY 1/2 INCH (13 MM) FROM AND MOVED BACK AND FORTH OVER THE JUNCTION OF THE TWO MATERIALS TO BE JOINED. THE WELDING TOOL SHALL BE MOVED SLOWLY ENOUGH AS THE WELD PROGRESSES TO CAUSE A SMALL BEAD OF MOLTEN MATERIAL TO BE VISIBLE ALONG BOTH EDGES AND IN FRONT OF THE WELD STRIP. THE FOLLOWING SPECIAL REQUIREMENT SHALL APPLY WHEN THE LINER COVERAGE IS 360 DEGREES: WHEN GROUNDWATER IS ENCOUNTERED THE LINING JOINT SHALL NOT BE MADE UNTIL PUMPING OF GROUNDWATER HAS BEEN DISCONTINUED FOR AT LEAST THREE DAYS AND NO VISIBLE LEAKAGE IS EVIDENT AT THE JOINT. WHEN WELDING THE DOWNSTREAM SIDE OF A JOINT STRIP OR FLAP, DO NOT WELD 6 TO 8 INCHES (150 TO 200 MM) AT THE PIPE INVERT TO PROVIDE RELIEF OF POTENTIAL FUTURE GROUNDWATER BUILD-UP. 1.H. APPLICATION TO CAST -IN-PLACE CONCRETE STRUCTURES - SPECIAL REQUIREMENTS. LINER SHEETS SHALL BE CLOSELY FITTED AND PROPERLY SECURED TO THE INNER FORMS. SHEETS SHALL BE CUT TO FIT CURVED AND WARPED SURFACES USING A MINIMUM NUMBER OF SEPARATE PIECES. UNLESS OTHERWISE SHOWN ON THE PLANS„ THE LINING SHALL BE RETURNED AT LEAST 3 INCHES (75 MM) AT THE SURFACES OF CONTACT BETWEEN THE CONCRETE STRUCTURE AND ITEMS NOT OF CONCRETE (INCLUDING MANHOLE FRAMES, GATE GUIDES, CLAY PIPE OR BRICK MANHOLES AND CLAY OR CAST IRON PIPES). THE SAME PROCEDURE SHALL BE FOLLOWED AT JOINTS WHERE THE TYPE OF PROTECTIVE LINING IS CHANGED OR THE NEW WORK IS BUILT TO JOIN EXISTING UNLINED CONCRETE. AT EACH RETURN, THE RETURNED LINER SHALL BE SEALED TO THE ITEM IN CONTACT WITH THE PLASTIC -LINED CONCRETE. IF THE LINER CANNOT BE SEALED WITH ADHESIVE BECAUSE OF THE JOINT AT THE RETURN BEING TOO WIDE OR ROUGH OR BECAUSE OF SAFETY REGULATIONS, THE JOINT SPACE SHALL BE DENSELY CAULKED WITH LEAD WOOL OR OTHER APPROVED CAULKING MATERIAL TO A DEPTH OF 2 INCHES (50 MM) AND FINISHED WITH A MINIMUM OF 1 INCH 925 MM) OF AN APPROVED CORROSION RESISTANT MATERIAL 1.1. TESTING AND REPAIRING DAMAGED SURFACES. AFTER THE PIPE IS INSTALLED IN THE TRENCH, ALL SURFACES COVERED WITH LINING, INCLUDING WELDS, SHALL BE TESTED NTH AN APPROVED, CONTRACTOR SUPPLIED, ELECTRICAL HOLIDAY DETECTOR (TINKER & RASOR MODEL N0. AP -W WITH POWER PACK OR APPROVED EQUAL) WITH THE INSTRUMENT SET BETWEEN 18,000 AND 22,000 VOLTS. ALL WELDS SHALL BE PHYSICALLY TESTED BY A NONDESTRUCTIVE PROBING METHOD. ALL PATCHES OVER HOLES, OR REPAIRS TO THE LINER WHEREVER DAMAGE HAS OCCURRED, SHALL BE ACCOMPLISHED IN ACCORDANCE WITH SECTION 7-2.03(1.E) PARA. 8 ABOVE. EACH TRANSVERSE WELDING STRIP WHICH EXTENDS TO A LOWER EDGE OF THE LINER WILL BE TESTED BY THE PURCHASING AGENCY. THE WELDING STRIPS SHALL EXTEND 2 INCHES (50 MM) BELOW THE LINER TO PROVIDE A TAB. A 10 -POUND (5 KG) PULL WILL BE APPLIED TO EACH TAB. THE FORCE WILL BE APPLIED NORMAL TO THE FACE OF THE STRUCTURE BY MEANS OF A SPRING BALANCE. LINER ADJOINING THE WELDING STRIP WILL BE HELD AGAINST THE CONCRETE DURING APPLICATION OF THE FORCE THE 10 -POUND (5 KG) PULL WILL BE MAINTAINED IF A WELD FAILURE DEVELOPS, UNTIL NO FURTHER SEPARATION OCCURS. DEFECTIVE WELDS WALL BE RETESTED AFTER REPAIRS HAVE BEEN MADE. TABS SHALL BE TRIMMED AWAY NEATLY BY THE INSTALLER OF THE LINER AFTER THE WELDING STRIP HAS PASSED INSPECTION. INSPECTION SHALL BE MADE WITHIN 2 DAYS AFTER THE JOINT HAS BEEN COMPLETED IN ORDER TO PREVENT TEARING THE PROJECTING WELD STRIP AND CONSEQUENT DAMAGE TO THE LINER FROM EQUIPMENT AND MATERIALS USED IN OR TAKEN THROUGH THE WORK. SHOP DRAWINGS. CONTRACTOR SHALL SUBMIT MANUFACTURER INFORMATION SHOWING DIMENSIONAL, MATERIAL AND JOINT CRITERIA TO THE ENGINEER FOR REVIEW. PIPE TRENCH CLASSIFICATION. RCP CLASS IV SHALL BE INSTALLED PER ASTM TRENCH DESIGNATION "C". RCP CLASS V SHALL BE INSTALLED PER ASTM TRENCH DESIGNATION W. PVC FOR PIPE SIZES 18" AND LESS. POLY VINYL CHLORIDE PIPE SHALL MEET THE FOLLOWING REQUIREMENTS: 1. MATERIAL PVC PIPE SHALL MEET OR EXCEED ALL REQUIREMENTS SET FORTH IN ASTM D 3034 WITH SDR OF 35. ELASTOMERIC SEALS AND JOINTS SHALL CONFORM TO ASTM D 3212 AND ASTM F 477. 2. TESTING. MANUFACTURING TESTING METHODS SHALL CONFORM TO ASTM F-679 (T -WALL). CERTIFICATES OF COMPLIANCE SHALL BE MADE AVAILABLE TO THE ENGINEER. 3. INSTALLATION. INSTALLATION OF PIPE SHALL FOLLOW MANUFACTURER'S GUIDELINES, THESE SPECIFICATIONS AND ASTM D 2321 "UNDERGROUND INSTALLATION OF FLEXIBLE THERMOPLASTIC SEWER PIPE 4. FIELD TESTS. IN -FIELD PRESSURE TESTS SHALL CONFORM TO THESE SPECIFICATIONS AND THE FOLLOWING: DEFLECTION MEASUREMENT OF PVC PIPE. AFTER 30 DAYS OF INSTALLATION THE CONTRACTOR SHALL MEASURE PIPE DEFLECTION BY PULLING A GO -NO-GO 5% MANDREL THE MANDREL SHALL BE PULLED THROUGH THE PIPE WITH ROPE BY ONE PERSON WITHOUT MECHANICAL ADVANTAGE. THE MANDREL SHALL HAVE VANES AT LEAST AS LONG AS THE PIPE DIAMETER. THE MANDREL SHALL BE USED IN STRICT CONFORMANCE WITH PIPE AND MANDREL MANUFACTURER'S RECOMMENDATIONS. THE MANDREL DIAMETER WILL BE CALCULATED USING THE FOLLOWING FORMULA: MANDREL DIAMETER = BASE PIPE I.D. -(Y/100 X BASE PIPE I.D.) WHERE Y = ALLOWABLE DEFLECTION IN % (5%) BASE I.D. = ACTUAL INSIDE PIPE DIAMETER (PROVIDED BY PIPE MANUFACTURER) THE MANDREL SHALL HAVE AN ODD NUMBER OF VANES WITH SEVEN (7) MINIMUM. THE MINIMUM LENGTH OF THE CIRCULAR PORTION OF THE MANDREL SHALL BE EQUAL TO THE NOMINAL DIAMETER OF THE PIPE ANY SECTION OF INSTALLED PIPE THAT FAILS THE MANDREL TEST SHALL BE EXCAVATED, RE -BACKFILLED, RECOMPACTED AND RETESTED UNTIL THE MANDREL TEST CAN BE PASSED. RE -ROUNDING WILL NOT BE ALLOWED. PIPE TRENCH CLASSIFICATION. PVC PIPE SHALL BE INSTALLED PER CITY STANDARD S-39, AS MODIFIED ON THE CONTRACT PLANS. COMPACTION ABOVE THE PIPE ZONE SHALL BE AS SHOWN ON THE PLANS. 7. TRENCH EXCAVATION THE EXCAVATION OF TRENCHES FOR PIPING LAID IN THE GROUND SHALL BE IN OPEN -CUT FROM THE SURFACE OF THE GROUND EXCEPT WHERE BORING IS REQUIRED. THE TRENCHES SHALL BE OF WIDTH AS SHOWN ON STANDARD S-39 AND DETAILED SECTIONS ON THE PLANS FOR PROPER PIPE INSTALLATION. THE HOLES FOR BELLS AND FITTINGS SHALL BE EXCAVATED BY HAND, TO A WIDTH PROVIDING UNIFORM BEARING ALONG THE LENGTH OF THE PIPE IT IS THE INTENTION OF THESE REQUIREMENTS TO PROVIDE FIRM, UNIFORM BEARING FOR THE PIPE. CONTRACTOR SHALL PROVIDE TRENCHING IN ACCORDANCE WITH THE DETAILED SECTIONS PROVIDED IN THE PLANS. SELECTION OF TRENCH TYPES WILL BE AS REQUIRED BY THE TYPES OF PIPE SELECTED FOR CONSTRUCTION. STORM DRAIN AND UTILITY CONDUIT INSTALLATIONS SHALL MEET CITY STANDARD S-39. TRENCH LINES SHALL MEET ALL FEDERAL AND STATE SAFETY REQUIREMENTS. 8. BRACING AND SHORING EXCAVATION SHALL BE SUPPORTED AS SET FORTH IN THE RULES, ORDERS, AND REGULATIONS OF THE STATE DIVISION OF INDUSTRIAL SAFETY. IF THE CONTRACTOR DESIRES TO DEVIATE FROM THE SAFETY ORDERS, HE SHALL SUBMIT DATA BY A REGISTERED CIVIL ENGINEER TO THE STATE DIVISION OF INDUSTRIAL SAFETY, JUSTIFYING THE ALTERNATE PROCEDURES TO BE USED. FAILURE TO COMPLY WITH ANY OF THESE RULES, ORDERS AND REGULATIONS SHALL BE SUFFICIENT CAUSE FOR THE STATE DIVISION TO IMMEDIATELY SUSPEND ALL WORK. COMPENSATION FOR LOSSES INCURRED BY THE CONTRACTOR BY SUCH AN EMERGENCY SUSPENSION SHALL NOT BE ALLOWED. DURING BACKFILLING, THE BOTTOM OF THE SHORING SHALL BE KEPT ABOVE THE LEVEL OF THE BACKFILL AT ALL TIMES. SECTION 6422 OF THE CALIFORNIA LABOR CODE REQUIRES THE CONTRACTOR TO SUBMIT TO THE ENGINEER A DETAILED PLAN, DRAWING THE DESIGN OF SHORING, BRACING, SLOPING OR OTHER PROVISIONS TO BE MADE BY THE CONTRACTOR FOR THE PURPOSE OF WORKER PROTECTION FROM THE HAZARD OF CAVING GROUND DURING THE EXCAVATION OF TRENCHES NECESSARY FOR THE CONSTRUCTION OF THE PROJECT. IF SUCH PLAN VARIES FROM THE SHORING SYSTEM STANDARD ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS, THE PLANS SHALL BE PREPARED AND CERTIFIED BY A REGISTERED CIVIL OR STRUCTURAL ENGINEER; HOWEVER, USE OF SYSTEMS THAT ARE LESS EFFECTIVE THEN THOSE REQUIRED BY THE CONSTRUCTION SAFETY ORDERS IS PROHIBITED ON THIS PROJECT. 9. TRENCH BACKFILL TRENCHES SHALL NOT BE LEFT OPEN FARTHER THAN THREE HUNDRED (300) FEET IN ADVANCE OF PIPE LAYING OPERATIONS OR TWO HUNDRED (200) FEET TO THE REAR THEREOF, UNLESS OTHERWISE PERMITTED BY THE ENGINEER. ALL WORK SHALL CONFORM TO THE APPLICABLE SECTIONS OF THE STANDARD SPECIFICATIONS, DATED JULY, 1992. BEDDING CLASS SHALL BE AS SPECIFIED IN THE PIPE OPTIONS. STORM DRAIN AND UTILITY CONDUIT INSTALLATIONS SHALL BE IN ACCORDANCE WITH CITY STANDARD ST -22, EXCEPT THAT COMPACTION SHALL BE NO LESS THAN NINETY PERCENT (90%) UP TO THIRTY INCHES (30") FROM FINISHED GRADE. BACKFILL MATERIALS IN THE PIPE ZONE SHALL BE PLACED IN LAYERS NOT TO EXCEED TWELVE (12) INCHES SIMULTANEOUSLY, ON EACH SIDE OF THE PIPE, IN SUCH A MANNER AS NOT TO DAMAGE OR DISTURB THE PIPE OR ITS ALIGNMENT AND GRADE BACKFILL MATERIAL ABOVE THE PIPE ZONE SHALL BE FREE OF DELETERIOUS MATERIALS AND LUMPS OR STONES EXCEEDING THREE (3) INCHES IN GREATEST DIMENSION AND SHALL BE PLACED IN LAYERS NOT EXCEEDING EIGHTEEN (18) INCHES. EACH LAYER SHALL BE THOROUGHLY COMPACTED BY VIBRATORY OR MECHANICAL TAMPING, OR BY A COMBINATION OF THESE METHODS. FLOODING AND JETTING SHALL NOT BE ALLOWED. THERE MUST BE AT LEAST ONE FOOT OF COVER OVER THE PIPE BEFORE COMPACTION ABOVE THE PIPE ZONE WILL BE ALLOWED. IMPORTED BEDDING AND BACKFILL MATERIAL SHALL BE OBTAINED, AND ANY EXCESS BEDDING AND BACKFILL MATERIAL SHALL BE DISPOSED, BY ANY LEGAL MEANS AT THE DISPOSAL OF THE CONTRACTOR. THE CONTRACTOR MAY SUBMIT TO THE ENGINEER SIEVE ANALYSIS FOR UTILIZATION OF IN-SITU MATERIALS. ACHIEVING FIRM BEDDING BELOW PIPE SPRINGLINE. CONTRACTOR SHALL PROVIDE "FIRM BEDDING" SUPPORT FOR THE PIPE BELOW THE SPRINGLINE FIRM BEDDING MEANS THAT THE PIPE MUST REST ON THE GRANULAR MATERIAL SPECIFIED PREVIOUSLY IN THE SPECIFICATIONS BELL OR COUPLING HOLES SHALL BE CAREFULLY EXCAVATED AT PROPER INTERVALS, SO THAT NO PART OF THE LOAD IS SUPPORTED BY THE BELLS OR COUPLINGS. DURING BEDDING AND BACKFILLING, CONSOUDATION OF MATERIAL AROUND AND UNDER BELLS AND COUPLINGS SHALL BE AVOIDED. CONTRACTOR SHALL SHOVEL -SLICE OR HAND TAMP BEDDING IN THE HAUNCH AREAS, AS 13. ALL SEWER STUBS SHALL BE CLOSED WITH A STANDARD PLASTIC PLUG. SOLVENT WELDED. I ' THIS WALL MINIMIZE VOIDS BENEATH THE PIPE AND IN THE HAUNCH AREAS. ", SHOVEL -SLICING OR HAND TAMPING SHALL BE DONE BEFORE THE BEDDING IS BROUGHT 14. ALL MANHOLES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF BAKERSFIELD UP TO THE QUARTER POINT OF THE PIPE. STANDARD DRAWINGS S-7, S-8, AND S-21 AND SECTIONS 70-1.02H AND 71-1.07 OF THE STANDARD SPECIFICATIONS OF THE STATE OF CALIFORNIA, DEPARTMENT OF TRANSPORTATION, INITIAL BACKFILL "BEDDING MATERIAL" AS SPECIFIED BY ASTM 2321-8 SHALL BE USED CURRENT EDITION. ALL CLEANOUTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY IN THE PIPE ZONE FOR INITIAL BACKFILL. AFTER THE PIPE HAS BEEN PROPERLY LAID OF BAKERSFlELD STANDARD DRAWING S-20. o AND INSPECTED, INITIAL BACKFILL SHALL BE PLACED ON BOTH SIDES AND OVER THE ""or C14 PIPE TO SUCH A DEPTH THAT, AFTER THOROUGH CONSOLIDATION, THE FINAL DEPTH MANHOLES SHALL BE TYPE 'A" FOR PIPES UNDER 48" IN DIAMETER AND TYPE "B" FOR SHALL BE AT LEAST TO THE ELEVATION SHOWN ON THE PLANS. THE MATERIAL SHALL PIPES 48" IN DIAMETER OR LARGER. UNLESS NOTED OTHERWISE. THE BOTTOM MANHOLE CD BE CONSOLIDATED BY VIBRATORY OR MECHANICAL TAMPING AND THE EQUIPMENT AND MANNER OF TAMPING MUST BE APPROVED IN WRITING BY THE ENGINEER PRIOR TO (n BARREL AT THE MANHOLE FOUNDATION SHALL BE SET ON A 2" MORTAR BED OR SET ON z COMMENCING OPERATION. IMPACT EQUIPMENT MAY BE ALLOWED UNDER THE DIRECTION KENT -SEAL, IN A GROOVED FOUNDATION. z OF THE ENGINEER. HOWEVER, THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE 15. STORM DRAIN PIPE W Wm 160 RESULTING FROM THE USE OF THIS EQUIPMENT. HYDRA -HAMMER WILL NOT BE PERMITTED. STORM DRAIN PIPE. CONTRACTOR SHALL UTILIZE RCP PIPE, CLASS III WITH RUBBER H GASKET JOINTS PER ASTM SPECIFICATION C-76, UNLESS OTHERWISE NOTED ON THE . SUBSEQUENT BACKFILL ABOVE THE LEVEL OF IN111AL BACKFILL, THE TRENCH MAY BE CONTRACT PLANS. 0 BACKFILLED WITH NATIVE MATERIAL RESULTING FROM TRENCH EXCAVATION, OR AT THE z OPTION OF THE CONTRACTOR, SELECT IMPORTED MATERIALS MAY BE USED. NATIVE REINFORCED CONCRETE PIPE. REINFORCED CONCRETE PIPE SHALL CONFORM TO THE w MATERIAL OR IMPORTED MATERIAL MAY BE COMPACTED BY TAMPING AND/OR ROLLING, PROVISIONS IN SECTION 65, 'REINFORCED CONCRETE PIPE", OF THE STANDARD ® R� USING EQUIPMENT AND METHODS APPROVED BY THE ENGINEER. SPECIFICATIONS AND THESE SPECIAL PROVISIONS. 4 "' Ch 2-1 WHEN THE CONTRACTOR COMPACTS BY TAMPING AND/OR ROLLING, THE BACKFILL EXCEPT AS OTHERWISE DESIGNATED BY CLASSIFICATION ON THE PLANS OR IN THE V __j MATERIAL SHALL BE PLACED IN LAYERS NOT EXCEEDING EIGHTEEN (18) INCHES IN LOOSE SPECIFICATIONS, JOINTS FOR CULVERT AND DRAINAGE PIPES SHALL CONFORM TO THE t1J DEPTH, EACH LAYER BEING THOROUGHLY COMPACTED BY TAMPING AND/OR ROLLING PLANS OR SPECIFICATIONS FOR STANDARD JOINTS. BEFORE SUCCEEDING LAYERS ARE PLACED. HYDROSTATIC TESTS SPECIFIED BY SECTION 65-1.08 "LAYING SIPHON AND PRESSURE COMPACTION OF SUBSEQUENT BACKFILL WITHIN TWO AND ONE-HALF (2-1/2) FEET OF PIPE", OF THE STANDARD SPECIFICATIONS WILL NOT BE REWIRED. ::E FINISHED PERMANENT SURFACING GRADE SHALL BE ACCOMPLISHED BY TAMPING AND/OR ROWING AS SPECIFIED ABOVE WHERE THE TRENCH IS WITHIN THE PAVEMENT ON REINFORCED CONCRETE PIPE SHALL HAVE RUBBER GASKETED JOINTS CONFORMING TO STREETS, THE BACKFILL WITHIN TWO AND ONE-HALF (2-1/2) FEET OF FINISHED SECTION 65-1.06B, "RUBBER GASKETED JOINTS-, OF THE STANDARD SPECIFICATIONS. CD PERMANENT GRADE SHALL BE COMPACTED TO NINETY PERCENT (907.) RELATIVE HANDLING OF MATERIALS. ALL PIPE, FITTINGS, SPECIALS AND CASTINGS MUST BE 0 M COMPACTION. CAREFULLY HANDLED AT ALL TIMES. ONLY SUITABLE AND PROPER EQUIPMENT AND M O SUBSEQUENT BACKFILL PLACED BY TAMPING AND/OR ROWING SHALL BE FREE FROM APPLIANCES SHALL BE USED FOR THE SAFE LOADING, HAULING, UNLOADING, HANDLING °' o AND PLACING OF MATERIALS, SPECIAL CARE SHALL BE EXERCISED SO THAT PREFORMED O Q 14, M � STONES OR LUMPS EXCEEDING THREE (3) INCHES IN GREATEST DIMENSIONS, VEGETABLE r) RESILIENT JOINTS ON PIPE AND FITTINGS WILL NOT BE DAMAGED. ANY PIPE OR FITTING O Z 00 MATTER, OR OTHER UNSATISFACTORY MATERIALS. U O 14- z WITH A JOINT DAMAGED OR FLATTENED WILL CAUSE THAT PIPE OR FITTING TO BE REJECTED. Z U- I IN NO CASE SHALL JETTING BE ALLOWED FOR BACKFILL COMPACTION WITHIN THE STREET. a J o WHEN APPROVED BY THE ENGINEER, JETTING MAY BE USED IN NON -STREET AREAS. -j Q It PIPE LAYING. NO PIPE SHALL BE LAID UNTIL THE ENGINEER INSPECTS AND APPROVES w U M BACKFILL TESTING AND COMPACTION, TESTING OF BACKFILL MATERIALS AND COMPACTION THE CONDITION OF THE BOTTOM OF THE TRENCH. PIPE SHALL BE INSTALLED IN STRICT W 00 'EARTHWORK- ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. I o 9 SHALL BE IN ACCORDANCE WITH SECTION 19, EARTHWORK AND SECTION 6-3, -� r - "TESTING", OF THE STANDARD SPECIFICATIONS, STATE OF CALIFORNIA, DEPARTMENT OF PIPE LAYING SHALL BEGIN FROM THE DOWNSTREAM END OF THE STORM DRAIN OR AS O E CD PUBLIC WORKS, DIVISION OF HIGHWAYS. EACH LAYER OF BACKFILL MATERIAL SHALL o x " DIRECTED BY THE ENGINEER. PIPE LAYING SHALL PROCEED WITH EACH PIECE LAID TRUE MEET THE COMPACTION, SAND EQUIVALENT, AND GRADATION REQUIREMENTS BEFORE THE N NEXT LAYER IS PLACED. TO UNE AND GRADE, AND IN SUCH A MANNER AS TO FORM A CLOSE CONCENTRIC JOINT Y m WITH THE ADJOINING PIPE AND TO PREVENT SUDDEN OFFSETS IN THE FLOW UNE. AS THE 9 8 EACH LAYER OF BACKFILL SHALL BE THOROUGHLY COMPACTED TO THE RELATIVE WORK PROGRESSES, THE INTERIOR OF THE PIPE SHALL BE CLEARED OF ALL DIRT AND m o COMPACTION OF NOT LESS` THAN IS SHOWN ON CITY OF BAKERSFIELD STANDARD S-39 DEBRIS OF EVERY DESCRIPTION. PIPE SHALL NOT BE LAID WHEN THE CONDITION OF THE AS MODIFIED ON THE CONTRACT PLANS. EXCEPT THAT COMPACTION WITHIN THE AS OR THE WEATHER UNSUITABLE. AT LOSES WHEN WORK IS NOT IN PROGRESS, ROADWAY STRUCTURAL SECTION SHALL BE NO LESS THAN NINETY PERCENT (90%) OPEN ENDS OF PIPE AND FITTINGS SHALL BE CLOSED. .9' RELATIVE COMPACTION FOR THE TOP FINISHED 30% AND SHALL BE DETERMINED BY WITH BELLED END PIPE, BELL HOLES SHALL THEN BE EXCAVATED AT EACH JOINT TO CALIFORNIA TEST METHODS 216 OR 231, OR ASTM (CURRENT EDITION) D1557 AND ONE FACILITATE THE JOINT OPERATIONS, AND SHALL BE ONLY OF SUFFICIENT SIZE FOR THAT OF THE FOLLOWING D2922 OR D1556. PURPOSE. IN ORDER THAT BELL HOLES MAY BE PROPERLY LOCATED, NOT MORE THAN N SIX (6) HOLES SHALL BE EXCAVATED AHEAD OF ACTUAL PIPE LAYING, ON ACCOUNT OF b W".IF THE RELATIVE COMPACTION, AS DETERMINED BY TESTING, FAILS TO MEET THE THE VARIATIONS IN JOINT CONSTRUCTION OPERATIONS. �' z SPECIFIED PERCENTAGE, THE TRENCH SHALL BE RE -EXCAVATED AND RE -COMPACTED. COMPACTION TESTS WILL BE THE SUBDIVIDERS RESPONSIBILITY. THE NUMBER AND ' . BEING FLUSHED INTO AN EXISTING STORM DRAIN UNE. M THE CONTRACTOR SHALL MAKE PROVISIONS FOR PREVENTING FOREIGN MATERIAL FROM `V :� c3 8 > LOCATIONS OF THE TESTS SHALL BE DETERMINED BY THE CITY ENGINEER. .4 d CUTTING PIPE. THE CONTRACTOR SHALL PERFORM ALL WORK OF CUTTING PIPE AND 10. SEWER PIPE INSTALLATION SPECIAL CASTING NECESSARY TO THE ASSEMBLY, ERECTION, AND COMPLETION OF THE WORK. ALL PIPE SHALL BE CUT TO FIT ACCURATELY, WITH SMOOTH EDGES AND FACES. S SEWER PIPE SHALL CONFORM TO THE PLANS, AND THESE SPECIAL PROVISIONS. THE THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CORRECTNESS OF CUTTING AND NO PRICE PER LINEAL FOOT SHALL INCLUDE BUT NOT BE LIMITED TO EXCAVATION, BEDDING ADDITIONAL COMPENSATION WILL BE ALLOWED FOR ANY MATERIALS WHICH ARE DAMAGED AND BACKFILL. OR INCORRECTLY CUT. -� HANDLING OF MATERIALS. ALL PIPE, FITTINGS, SPECIALS AND CASTINGS MUST BE 16. QED f JACKED PIPE c CAREFULLY HANDLED AT ALL TIMES. ONLY SUITABLE AND PROPER EQUIPMENT AND APPLIANCES SHALL BE USED FOR THE SAFE LOADING, HAULING, UNLOADING. HANDLING CASING OR SMOOTH OUTSIDE WALLED PIPE FOR BORED/JACKED PIPE MALL BE AND PLACING OF MATERIALS, SPECIAL CARE SHALL BE EXERCISED SO THAT PREFORMED INSTALLED. IT SHALL HAVE EVEN BEARING THROUGHOUT ITS LENGTH AND SHALL SLOPE RESILIENT JOINTS ON PIPE AND FITTINGS WILL NOT BE DAMAGED. ANY PIPE OR FITTING TOWARD ONE END. SPACE BETWEEN CASING AND PIPELINE SHALL BE BACKFILLED WITH m WITH A JOINT DAMAGED OR FLATTENED WALL CAUSE THAT PIPE OR FITTING TO BE SAND. IF THE PIPE AND CASING ARE INSTALLED BY BORING, THE SPACE AROUND THE REJECTED. CASING ALSO SHALL BE BACKFILLED WITH GROUT OR SAND. THE ENDS OF SPACE PIPE LAYING. NO PIPE SHALL BE LAID UNTIL THE ENGINEER INSPECTS AND APPROVES BETWEEN THE CASING AND THE PIPE SHALL BE SEALED WITH GROUT. THE STRENGTH OF PIPE DESIGNATED IN THE PLANS OR SPECIFICATIONS IS DETERMINED FOR VERTICAL THE CONDITION OF THE BOTTOM OF THE TRENCH. PIPE SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. PIPE LAYING SHALL BEGIN LOAD ONLY ANY ADDITIONAL STRENGTH REQUIRED BY BORING/JACKING OPERATIONS FROM THE DOWNSTREAM END OF THE TRUNK SEWER OR AS DIRECTED BY THE ENGINEER. SHALL BE FURNISHED AT THE CONTRACTOR'S EXPENSE. PIPE LAYING SHALL PROCEED WITH EACH PIECE LAID TRUE TO UNE AND GRADE, AND IN THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR APPROVAL ALL PLANS OF SUCH A MANNER AS TO FORM A CLOSE CONCENTRIC JOINT WITH THE ADJOINING PIPE BORING/JACKING OPERATIONS PRIOR TO BORING OR JACKING. AND TO PREVENT SUDDEN OFFSETS IN THE FLOW LINE AS THE WORK PROGRESSES, THE INTERIOR OF THE PIPE SHALL BE CLEARED OF ALL DIRT AND DEBRIS OF EVERY BORING JACKING OPERATIONS SHALL BE CONDUCTED IN A SAFE AND EFFICIENT MANNER, DESCRIPTION. PIPE SHALL NOT BE LAID WHEN THE CONDITION OF THE TRENCH OR THE BORING/ JACKING IS UNSUITABLE AT TIMES WHEN . WORK IS NOT IN PROGRESS, OPEN ENDS OF CONSISTENT WITH CURRENT ACCEPTED PROCEDURES. WATER BORING SHALL NOT BE V) PIPE AND FITTINGS SHALL BE CLOSED. PERMITTED. THE CASING PIPE SHALL BE JACKED WITH SUCH PRECISION THAT WILL o ALLOW THE REPLACEMENT OF THE PIPELINE TO THE LINE AND GRADE AS INDICATED ON V) WITH BELLED END PIPE, BELL HOLES SHALL THEN BE EXCAVATED AT EACH JOINT TO THE PLANS. Uj FACILITATE THE JOINT OPERATIONS, AND SHALL BE ONLY OF SUFFICIENT SIZE FOR THAT UPON COMPLETION OF THE INSTALLATION OF THE CASING AND INSTALLATION OF THE PURPOSE IN ORDER THAT BELL HOLES MAY BE PROPERLY LOCATED, NOT MORE THAN V HOLES SHALL BE EXCAVATED AHEAD IN JOINT CONSTRUCTION OPERATIONS. ACTUAL PIPE LAYING, ON ACCOUNT OF PIPELINE TO GRADE, THE VOID BETWEEN THE CASING OR RC PIPE AND THE EXCAVATION THE V SIX RSHALL BE COMPLETELY FILLED WITH SAND, COMPACTED BY THE USE OF AIR -BLOWING TIONS. SAND EQUIPMENT OR ANY OTHER MEANS ACCEPTABLE TO THE ENGINEER UPON HIS CUTTING PIPE THE CONTRACTOR SHALL PERFORM ALL WORK OF CUTTING PIPE AND APPROVAL SPECIAL CASTING NECESSARY TO THE ASSEMBLY, ERECTION, AND COMPLETION OF THE ALL IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN A SAFE OPERATION AT WORK. ALL PIPE SHALL BE CUT TO FIT ACCURATELY, WITH SMOOTH EDGES AND FACES. TIMES. SHOULD THE TUNNEL HEADING OPERATIONS RESULT IN DANGEROUS T THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CORRECTNESS OF CUTTING AND NO UNREASONABLE SLOUGHING OF MATERIAL WHICH MAY JEOPARDIZE THE SAFETY OF ADDITIONAL COMPENSATION WILL BE ALLOWED FOR ANY MATERIALS WHICH ARE DAMAGED OR INCORRECTLY CUT. WORKERS OR THE STABILITY OF THE SOIL AND ROADWAY ABOVE, THE CONTRACTOR SHALL FURNISH AND INSTALL BREASTBOARDING AND/OR FACE CLOSURE WITH W PIPELINE TESTING. ALL SEWERS SHALL BE TESTED FOR TIGHTNESS WHEN COMPLETED SUFFICIENT JACKS TO INHIBIT THE SLOUGHING AND/OR CLOSING THE WORK FACE c AND READY FOR SERVICE. TESTING SHALL BE CONDUCTED IN ACCORDANCE WITH THE THE CONTRACTOR, BEFORE RESUMING WORK, SHALL FURNISH THE ENGINEER WITH A UNIFORM PLUMBING CODE AIR TEST METHOD UPC SEC. 318-6(4). OR THE WATER DETAILED PLAN OF PRECEDING WITH THE WORK, FOR HIS REVIEW AND APPROVAL EXFlLTRATION TEST OR AIR PRESSURE TEST PER SECTION 306-1.4, "TESTING PIPELINES' ANY AND ALL EXPENSES THEREFORE WILL BE CONSIDERED AS INCLUDED IN THE BID OF THE 1994 EDITIONS, 'STANDARD SPECIFICATIONS" FOR PUBLIC WORKS CONSTRUCTION, PRICE AND NO ADDITIONAL COMPENSATION WILL BE MADE THEREFORE. AND CHAPTER 1.3 OF THE CITY OF BAKERSFIELD SUBDIVISION DESIGN MANUAL, AND THE 17. MINOR STRUCTURES PIPE SUPPLIER'S REQUIREMENTS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER 24 HOURS PRIOR TO ANY TESTING. MINOR STRUCTURES. PORTLAND CEMENT CONCRETE MINOR STRUCTURES SHALL CLEANING PIPE LINES. CARE SHALL BE EXERCISED IN LAYING OF PIPE LINES TO CONFORM, IN DESIGN, MATERIALS, AND CONSTRUCTION, TO THE PROVISIONS OF EXCLUDE DIRT AND ANY OTHER FOREIGN MATERIAL WHEN PIPE LAYING IS INTERRUPTED, SECTIONS 70-1.02 H OF THE STANDARD SPECIFICATIONS AND THESE SPECIAL AS AT NIGHT, THE PIPE ENDS SHALL BE SUITABLY CLOSED. UPON COMPLETION, AND PROVISIONS. MANHOLES SHALL CONFORM TO THE CITY OF BAKERSFIELD STANDARDS BEFORE PLACING iS-7 AND S-8. DROP INLETS SHALL CONFORM TO THE CITY OF BAKERSFIELD INTO SERVICE, ALL LINES SHALL BE FLUSHED AND MANDRELLED TO (n REMOVE ANY DIRT OR FOREIGN MATERIALS WHICH WOULD CLOG PUMPS, EQUIPMENT, STANDARD S-12. TEMPORARY INLET GRATES SHALL CONFORM TO DETAILS ON THE SPRAY HEADS, ETC. THE CONTRACTOR SHALL MAKE PROVISIONS FOR PREVENTING PLANS Q Z FOREIGN MATERIAL FROM BEING FLUSHED INTO AN EXISTING SEWER UNE THE PRECAST CYLINDER, TAPER, AND ECCENTRIC FLAT TOP SECTIONS SHALL MEET THE .»J Q SEWER LATERALS SEWER LATERALS SHALL CONFORM TO THIS IN EVERY REGARD. STRENGTH REQUIREMENT OF ASTM. C-478. EACH SUCCESSIVE MANHOLE SECTION SHALL IL p EXISTING SEWER LATERALS SHALL BE LOCATED BY THE CONTRACTOR AND CONNECT TO BE SET ON A BED OF PORTLAND CEMENT GROUT OR 'KENT SEAL* TO MAKE A AND EXTENDED OR RECONSTRUCTED ACCORDING TO THE PLANS. COMPRESSION WATERTIGHT JOINT, SHALL BE NEATLY POINTED ON THE INSIDE, AND SHALL BE SET N Z < COUPLINGS MAY BE UTILIZED FOR CONNECTING TO EXISTING LATERALS. POSITIVE GRADE PLUMB. .o Q ♦ 1 TO THE TRUNK SEWER SHALL BE MAINTAINED AND INVERT GRADES SET AS CALLED ON 18. ADJUST SURLY MONUMENT ENCA��EN� V..� THE PLANS. SEWER WYES SHALL BE INSTALLED ON THE TRUNK IN ACCORDANCE WITH a NJ 0 i.L. THE PIPE MANUFACTURERS RECOMMENDATIONS. PAYMENT FOR SEWER LATERALS WILL BE SURVEY MONUMENT AND FRAME AND COVER WITH ENCASEMENTS SHALL BE ADJUSTED OR PAID AS SEWER FOR THE APPROPRIATE DIAMETERS INSTALLED NEW TO FINISH GRADE AT THE LOCATIONS SHOWN ON THE PLANS, IN W ACCORDANCE WITH THESE SPECIAL PROVISIONS, AND CITY STANDARD S-29. 11. SYSTEM TESTING THE SURFACE OF THE CONCRETE SHALL BE PROTECTED FROM PUBLIC TRAFFIC FOR A a Q 0) A MANDREL TEST AND PRESSURE TEST SHALL BE PERFORMED ON INSTALLED PIPE MINIMUM OF THREE DAYS. I m I. - IN ACCORDANCE WITH THE CITY OF BAKERSFIELD SUBDIVISION MANUAL AND THE 0 RECOMMENDATIONS OF THE MANUFACTURER. AT THE OPTION OF THE CONTRACTOR, MINOR CONCRETE CONTAINING A MINIMUM OF od SEVEN SACKS OF CEMENT PER CUBIC YARD MAY BE USED AND THE TIME REWIRED FOR I PRIOR TO FINAL ACCEPTANCE, ALL SEWER LINES SHALL BE INSPECTED WITH VIDEO EQUIPMENT PROTECTION OF THE CONCRETE SURFACE FROM PUBLIC TRAFFIC SHALL BE REDUCED TO DESIGNED FOR THIS PURPOSE THE TELEVISION CAMERA SHALL HAVE THE CAPABILITY OF ROTATING A MINIMUM OF ONE DAY. 0C W 3607, IN ORDER TO VIEW AND RECORD THE TOP AND SIDES OF THE PIPE, AS REWIRED. THE VIDEO W INSPECTION SHALL BE WITNESSED BY THE CITYS CONSTRUCTION INSPECTOR, WHO WILL ALSO INITIAL THE MONUMENT WILL BE SET BY OTHERS. THE OWNER WILL PROVIDE SURVEYS. AND DATE THE 'CHAIN OF CUSTODY" FORM. THE SUBDIVIDER SHALL IMMEDIATELY NOTIFY CITY OF CONTRACTOR SHALL GIVE THE OWNER 24 HOURS NOTICE WHEN SURVEYS ARE REQUIRED. ANY PIPE LOCATIONS REVEALED TO BE NOT IN COMPLIANCE WITH THE SPECIFICATIONS. A RECORDED III Z VIDEO CASSETTE, THE COMPLETED "CHAIN OF CUSTODY" FORM AND A WRITTEN LOG (WHICH INCLUDES ANY MONUMENT FRAME OR COVER DAMAGED BY THE CONTRACTOR OR HIS OPERATIONS 0) THE STATIONING, BASED ON THE STATIONING OF THE APPROVED PLANS, OF ALL CONNECTED LATERALS) SHALL BE REPLACED BY THE CONTRACTOR AT NO COST TO THE OWNER. OF THE INSPECTION SHALL BE PROVIDED FOR VIEWING, AND SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO ACCEPTANCE. AFTER ACCEPTANCE, THE VIDEO CASSETTE SHALL BECOME THE PROPERTY OF ' THE CITY. ,t; 12. WYE FITTINGS SHALL BE INJECTION MOLDED IN-LINE TYPE AND SHALL BE USED FOR ALL LATERAL CONNECTIONS AND SHALL BE ROTATED A MINIMUM OF 23 DEGREES ABOVE THE HORIZONTAL PLANE RUNNING THROUGH THE CENTERLINE OF THE MAIN. ALL LATERALS SHALL BE 4" IN DIAMETER EXCEPT AS NOTED ON PLANS, EXTENDING A MINIMUM OF 4' BEYOND THE PROPERTY LINE OR RIGHT-OF-WAY LINE WITH 30" OF COVER AT FLOW LINE SURFACE MARKERS FOR SEWER LATERALS SHALL BE INSTALLED AT THE PROPERTY UNE OR RIGHT-OF- WAY LINE AS SHOWN IN THE "SEWER LATERAL MARKER" DETAIL, C.O.B. STD. DET. SW -1. LATERALS SHALL BE A MINIMUM OF 5.0' DEEP AND A MAXIMUM OF i DEEP AT PROPERTY UNE OR RIGHT-OF-WAY LINE AND A MINIMUM OF 2.5' DEEP AT FLOWLINE 1.2-6663 Ph 1 & 2 Rev Know what's below. 0111 before you dig. CAP 8" SEWER STUB AT PHASE BOUNDARY SUNCHASE DRIVE SEE SHEET 5 ATYPICAL EXISTI Ga C0MA4E1-?(,'_,'1AL AREA TRACT BOUNDARY �� ssf�sf�s����ff���+�Es• sf��s •���ss f��s� �f���• ��f+E�s+t �ssa��• �sff�� �sff�� •��f�� �a�L � N I An � I r_ , � T u r_ z I I ti 1 J ATYPICAL J J _ I ,_ I Z3' W A N I I I -••� J J �-- � I � y o I I I J J 1 -� I I J � �+ E- I ( I o g '+� O J O J J • J I J J O - Y \ QZ I ^ I Mg I MO ( Og I MO I M'p O a■/ ooi- O 00 0. nM O Q p p I 0 I d0 I V� OQ 11 I 12� ( MM ( MOf I �m 1 O I MO Mg I MO I MO Lhg .- N> o�- 00' O' O_d0 I o \ co W I , r� M M M ,,� I Ni v> I Ni of o ( t� o n ,y M o W) p ,� p vi Z 10 13 MW 0i I "! I I MM MM MM I ►70f ( C17 i MM Z J.j�W O O O Mg I MW 1Lya,11 -P + .� . 14 15 W 16 W 17 M W I 18. 15 W 14 M M "' , M W Z v 4: Mof Ki ai I Ki I c0 I JQ \ JJ\ O.. +O �� �� Na ooa W M I W ( MM MM r7 17O> I {. a0 g� o� Q ^N N� I +� I Oa 13 W=12 -�11 �� 10 9 I 8MM 7 6 + .+} dD op to a N : fn OD oD W N) �y Z W I rrj I I Z Z �N �' M^ M. + +� +O O +� �O ti d= O� a t0W eMW N O O O I F O �.- m oo CO -j + ro F M -} oo .� oo N s p I I to z L- O I Q P O N I N N •- - co _ ao . + a7 Q Woo ` i a' t -o �o I Qp ✓SE�a� 1i�1 �- ;Q o s� I :Q x ++ r-N+M �N •-N ( w� I �� I vW • 1• • 0 rn //nom u -^ Z - _ _ — U. .I Z ", .� _ N N .-. w M N J r' CV I .-- CV .-= _. N J 3 ` . W N o.� N N = I O ey Oi W W r I �' R" OD pip •� a f� s N CO .-�Q w t0 .- 1 O M Q M Q M N CV J (V Q' W N V G Iz J N 00 N 00 N p0 00 I : to ¢ CO - W U = CA W ] Q �- OD ++ Z 00 Z ¢ nn lino M NO x ,rn I 1 of� , Mp 0 MQ UN MQ MN MN NCV ( • IN IZ W Zr- _ I CAM C5 PHASE BOUNDARY _ - �, N W � < IZ 2 4 2 3 2 2 21 2 0 ' M 19 -16 `� -- ' N NCV aLri Om NN JO.�•Z N +ZIz N -�Z I Z 00 , tp0 x NO W .-� e00 �O.- I 1 Q = W COp M N N O Z W r W (r to to Li + z 1 •} O O O O^ r' J - a -- -- W�- o+ N.p 0 �_ ++ �� �.... ¢ 0 +Z Z�� 17 18 1 g fi I 1 1 2 p 3 �� 4 ppW I + Z N M M + Z I i Lp p r .- .f .- Lc ' I M W O s = U 00 JN O++ ++ T 1 M QOO �} +Z +ZI Z OMM GfO ( too p �O J -U 30' 3p' wQF z �� ��Q o0o a I I I++ �coco L^ m 5' x +z +z I +z ( iv 5 0�� Ito o oro a ia- z L- M a d v � I z Lc ce n o rn M I x 20 20' to to 7 a I 2s w� I¢ I W V) n �'- '� o: L< ¢ ++ a I I 5, 1¢ M o Q Z v> 5' ,a- �Lnzo I�¢� w¢t¢- 1 I to I N �d•� I�+r ¢ ( d I a I no I ¢ 5' ' �n + _ _ _ c� �n I in �n I I PHA E 2 , in a in cn cn LIU) P i ' in 20' 20' v v am -1 , o_+, z +04 N5' --- 5' I - - - - -- - -- - _ _ _ RASE ( 30' 30' I a F I I I d I w3 SUNCHASE DRIVE7 I I I 1 , I F I i -- -- -- -- I cn v) SEE SHEET 5R 0 30' 30' I I I A , 1 368 - - 366 - -- Cn UTILITY EASEMENT PER �. 362 DOCUMENT NO. 360 F 0 m J N 358 cn s 356 --- - i� rr 354 !- -- - 352--- -- R/W ,�. 350 ---- G) 348 348 -- Q a- 346 ` - --- PWASF an►tinAPY CAP 8" SEWER STUB AT PHASE BOUNDARY SUNCHASE DRIVE SEE SHEET 5 ATYPICAL EXISTI Ga C0MA4E1-?(,'_,'1AL AREA TRACT BOUNDARY �� ssf�sf�s����ff���+�Es• sf��s •���ss f��s� �f���• ��f+E�s+t �ssa��• �sff�� �sff�� •��f�� �a�L � N I An � I r_ , � T u r_ z I I ti 1 J ATYPICAL J J _ I ,_ I Z3' W A N I I I -••� J J �-- � I � y o I I I J J 1 -� I I J � �+ E- I ( I o g '+� O J O J J • J I J J O - Y \ QZ I ^ I Mg I MO ( Og I MO I M'p O a■/ ooi- O 00 0. nM O Q p p I 0 I d0 I V� OQ 11 I 12� ( MM ( MOf I �m 1 O I MO Mg I MO I MO Lhg .- N> o�- 00' O' O_d0 I o \ co W I , r� M M M ,,� I Ni v> I Ni of o ( t� o n ,y M o W) p ,� p vi Z 10 13 MW 0i I "! I I MM MM MM I ►70f ( C17 i MM Z J.j�W O O O Mg I MW 1Lya,11 -P + .� . 14 15 W 16 W 17 M W I 18. 15 W 14 M M "' , M W Z v 4: Mof Ki ai I Ki I c0 I JQ \ JJ\ O.. +O �� �� Na ooa W M I W ( MM MM r7 17O> I {. a0 g� o� Q ^N N� I +� I Oa 13 W=12 -�11 �� 10 9 I 8MM 7 6 + .+} dD op to a N : fn OD oD W N) �y Z W I rrj I I Z Z �N �' M^ M. + +� +O O +� �O ti d= O� a t0W eMW N O O O I F O �.- m oo CO -j + ro F M -} oo .� oo N s p I I to z L- O I Q P O N I N N •- - co _ ao . + a7 Q Woo ` i a' t -o �o I Qp ✓SE�a� 1i�1 �- ;Q o s� I :Q x ++ r-N+M �N •-N ( w� I �� I vW • 1• • 0 rn //nom u -^ Z - _ _ — U. .I Z ", .� _ N N .-. w M N J r' CV I .-- CV .-= _. N J 3 ` . W N o.� N N = I O ey Oi W W r I �' R" OD pip •� a f� s N CO .-�Q w t0 .- 1 O M Q M Q M N CV J (V Q' W N V G Iz J N 00 N 00 N p0 00 I : to ¢ CO - W U = CA W ] Q �- OD ++ Z 00 Z ¢ nn lino M NO x ,rn I 1 of� , Mp 0 MQ UN MQ MN MN NCV ( • IN IZ W Zr- _ I CAM C5 PHASE BOUNDARY _ - �, N W � < IZ 2 4 2 3 2 2 21 2 0 ' M 19 -16 `� -- ' N NCV aLri Om NN JO.�•Z N +ZIz N -�Z I Z 00 , tp0 x NO W .-� e00 �O.- I 1 Q = W COp M N N O Z W r W (r to to Li + z 1 •} O O O O^ r' J - a -- -- W�- o+ N.p 0 �_ ++ �� �.... ¢ 0 +Z Z�� 17 18 1 g fi I 1 1 2 p 3 �� 4 ppW I + Z N M M + Z I i Lp p r .- .f .- Lc ' I M W O s = U 00 JN O++ ++ T 1 M QOO �} +Z +ZI Z OMM GfO ( too p �O J -U 30' 3p' wQF z �� ��Q o0o a I I I++ �coco L^ m 5' x +z +z I +z ( iv 5 0�� Ito o oro a ia- z L- M a d v � I z Lc ce n o rn M I x 20 20' to to 7 a I 2s w� I¢ I W V) n �'- '� o: L< ¢ ++ a I I 5, 1¢ M o Q Z v> 5' ,a- �Lnzo I�¢� w¢t¢- 1 I to I N �d•� I�+r ¢ ( d I a I no I ¢ 5' ' �n + _ _ _ c� �n I in �n I I PHA E 2 , in a in cn cn LIU) P i ' in 20' 20' v v am -1 , o_+, z +04 N5' --- 5' I - - - - -- - -- - _ _ _ RASE ( 30' 30' I a F I I I d I w3 SUNCHASE DRIVE7 I I I 1 , I F I i -- -- -- -- I cn v) SEE SHEET 5R 0 30' 30' I I I A , 1 368 - - 366 - -- 364 - 362 o: a 360 F 0 m J N 358 cn s 356 --- - 354 !- -- - 352--- -- cq 350 ---- -c 348 348 -- Q a- 346 ` - --- 344 r --- -- - 342 - ! 340 -- 1 m - 336 - 334 - 11+00 CROOM LANE (STA. 11+40.07 C.L. TO 12+85.06 C.L.) SCALE: 1" = 50' HORIZONTAL 12+00 13+00 (STA. 11+40.07 TO 12+85.06) SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL 368 366 364 362 360 358 356 354 352 350 348 346 344 342 340 338 336 334 * CONTRACTOR TO HAVE SURVEYOR VERIFY LOCATION AND INVERT ELEVATION OF SEWER STUB PRIOR TO BACKFILL. LJWVVIYIL_14 1 1`I W. TO BE CONSTRUCTED WITH PHASE 1 AND TO BE REMOVED WITH PHASE 2. BB: TEMPORARY SEWER CLEANOUT NO. 15R TO BE CONSTRUCTED WITH PHASE 1 AND TO BE REMOVED WITH PHASE 2. DD: SEWER MAIN LINE AND LATERALS TO BE CONSTRUCTED WITH PHASE 1. LEGEND: ABBREVIATIONS CL CENTERLINE SMH SEWER MANHOLE INV INVERT SCO SEWER CLEANOUT SD STORM DRAIN SDMH STORM DRAIN MANHOLE MH MANHOLE EXIST EXISTING CB CATCH BASIN ELEV ELEVATION JB JUNCTION BOX R/W RIGHT OF WAY SCP STREET CONSTRUCTION PLAN T36 0 22 - TOP OF MANHOLE/TOP OF CLEANOUT ELEVATION —S—CONSTRUCT SEWER PER CITY STANDARDS ® CONSTRUCT SEWER MANHOLE TYPE "A" PER C.O.B. STD. SW -4 AND SW -5. ® CONSTRUCT SEWER CLEANOUT PER C•0.8. STD. SW -6. I vLIn `.MII" (STA. 10+00 C.L. TO 20+14.45 C.L.) SCALE: 1" = 50' HORIZONTAL (STA. 10+00.00 TO 20+14.45) SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL CONSTRUCT STORM DRAIN PER CITY STANDARDS ® CONSTRUCT STORM DRAIN MANHOLE TYPE aA" PER C.O.B. STD. SW -4 do SW -5. CONSTRUCT CATCH BASIN TYPE "Aa PER C.O.B. STD. D-14. — w WATER UNE SHOWN AT LOCATIONS OF PIPE CROSSINGS NOTES : 1) ALL CATCH BASINS ARE TO BE TYPE "A" WITH 3.5' OPENINGS PER C.O.B. STD. D-14 UNLESS OTHERWISE NOTED. 2) ALL PIPE ELEVATIONS SHOWN ARE INVERT ELEVATIONS UNLESS OTHERWISE NOTED. SECTION DESIGNATION: SECTION LETTER _2 SHEET *RE SECTION Is SHOWN FAI REVISION V / u lk� APPROVED l/ ROGER A. McINTOSH REVISION APPROVED BY- iV.6� :L PADILLA pl/ 1z V_77� R.C.E. 33322 DATE R.C.E. 67008 DATE - - 368 - 366 - 364 -- 362 - 360 - - 358 - 356 -- - 354 _._ 352 - - 350 -- 348 -- - 346 - 344 -- 342 - 340 - - 338 - - 336 -- 334 20+50 SCALE: 1 " = 50' 50' 25' 0' 50' 100' sss I I I 1 1 I I TRACT BOUNDARY 1 i f I I I (L ASHE ROAD I I 1 1 . ASHE ROAD SEE STREET PLANS (NOT A PART) N b/ Z N i N U M ULLiS � M > U o tt z Know what's below. Call before you dig. m J N s cq Z i ! Q 0 APPROXIMATE FINISH. i M �o j z U Wo O r -- - 8" _ WATER _ I -- - --- cn 0 DRAIN SEWER; STUB INVERT 18" -- -AT-.PHASE_.BOUNDARY-____-_._-_ INVERT 8" SEWER-� _ —__-- . - -- --�- — � -- � o Lc)O W • riT , _z1� �O =. w G. o z J + M•M N I SEE " NOTE DD 3 W WJ,� fv<) W J N a V) W;W W STALL _ f ±C.99- 1F ---DF- 8" -PVC- --0:3 -- --- i i 12+00 13+00 (STA. 11+40.07 TO 12+85.06) SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL 368 366 364 362 360 358 356 354 352 350 348 346 344 342 340 338 336 334 * CONTRACTOR TO HAVE SURVEYOR VERIFY LOCATION AND INVERT ELEVATION OF SEWER STUB PRIOR TO BACKFILL. LJWVVIYIL_14 1 1`I W. TO BE CONSTRUCTED WITH PHASE 1 AND TO BE REMOVED WITH PHASE 2. BB: TEMPORARY SEWER CLEANOUT NO. 15R TO BE CONSTRUCTED WITH PHASE 1 AND TO BE REMOVED WITH PHASE 2. DD: SEWER MAIN LINE AND LATERALS TO BE CONSTRUCTED WITH PHASE 1. LEGEND: ABBREVIATIONS CL CENTERLINE SMH SEWER MANHOLE INV INVERT SCO SEWER CLEANOUT SD STORM DRAIN SDMH STORM DRAIN MANHOLE MH MANHOLE EXIST EXISTING CB CATCH BASIN ELEV ELEVATION JB JUNCTION BOX R/W RIGHT OF WAY SCP STREET CONSTRUCTION PLAN T36 0 22 - TOP OF MANHOLE/TOP OF CLEANOUT ELEVATION —S—CONSTRUCT SEWER PER CITY STANDARDS ® CONSTRUCT SEWER MANHOLE TYPE "A" PER C.O.B. STD. SW -4 AND SW -5. ® CONSTRUCT SEWER CLEANOUT PER C•0.8. STD. SW -6. I vLIn `.MII" (STA. 10+00 C.L. TO 20+14.45 C.L.) SCALE: 1" = 50' HORIZONTAL (STA. 10+00.00 TO 20+14.45) SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL CONSTRUCT STORM DRAIN PER CITY STANDARDS ® CONSTRUCT STORM DRAIN MANHOLE TYPE aA" PER C.O.B. STD. SW -4 do SW -5. CONSTRUCT CATCH BASIN TYPE "Aa PER C.O.B. STD. D-14. — w WATER UNE SHOWN AT LOCATIONS OF PIPE CROSSINGS NOTES : 1) ALL CATCH BASINS ARE TO BE TYPE "A" WITH 3.5' OPENINGS PER C.O.B. STD. D-14 UNLESS OTHERWISE NOTED. 2) ALL PIPE ELEVATIONS SHOWN ARE INVERT ELEVATIONS UNLESS OTHERWISE NOTED. SECTION DESIGNATION: SECTION LETTER _2 SHEET *RE SECTION Is SHOWN FAI REVISION V / u lk� APPROVED l/ ROGER A. McINTOSH REVISION APPROVED BY- iV.6� :L PADILLA pl/ 1z V_77� R.C.E. 33322 DATE R.C.E. 67008 DATE - - 368 - 366 - 364 -- 362 - 360 - - 358 - 356 -- - 354 _._ 352 - - 350 -- 348 -- - 346 - 344 -- 342 - 340 - - 338 - - 336 -- 334 20+50 SCALE: 1 " = 50' 50' 25' 0' 50' 100' sss I I I 1 1 I I TRACT BOUNDARY 1 i f I I I (L ASHE ROAD I I 1 1 . ASHE ROAD SEE STREET PLANS (NOT A PART) N b/ Z N i N U M ULLiS � M > U o tt z Know what's below. Call before you dig. m J N Z 0 �o j z Wo 0 z a W z J N a a w o N 30' ' 30' 1 20' 20' I 1 * 5 * � 51 1 1 * � W � Z U i a * 1 I Z ap TRACT BOUNDARY $ t� ■ 1 :2 ! 10+00 — i 1 rn 1' * 4 I ! R/W yW� I 0 Z ! t Ic * 1 N t 1 I * I I4 3 2 ! 1 30' V) 30' I* - -- -- 20' 20' 1 I 5' i * I I I i 1 001 1 *--- -- ---I ±t SHANAGOLDEN STREET SEE SHEET 6 NOTES: AA: TEMPORARY TURN—AROUND EASEMENT PER DOCUMENT NO. TO BE CONSTRUCTED WITH PHASE 1 AND TO BE REMOVED WITH PHASE 2. DD. TC►ADADADV CCU/= PI CAAInI IT AIA 170 (STA. 10+00 C.L. TO 20+41.31 C.L.) SCALE: 1" = 50' HORIZONTAL ILH * ,n CL ASHE ROAD !) * TRACT BOUNDARY -Al * * ASHE ROAD SEE STREET PLANS (NOT A PART) -- - - 360 i 358 r 356 - - -' -- - 354 - - - - -- - 352 i - - - - - 350 -- - - - 348 I -- - - -- —-346 i - �- -- 344 o - -- - 342 - --� --- - 338 - �- -- - - 336 - t -- - 334 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 (STA. 10+00.00 TO 20+41.31) SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL 10-MV119 CL CENTERLINE SMH SEWER MANHOLE INV INVERT SCO SEWER CLEANOUT SD STORM DRAIN SDMH STORM DRAIN MANHOLE MH MANHOLE EXIST EXISTING CB CATCH BASIN ELEV ELEVATION JB JUNCTION BOX R/W RIGHT OF WAY SCP STREET CONSTRUCTION PLAN T 0.X4. 363.2 TOP OF MANHOLE/TOP OF CLEANOUT ELEVATION S CONSTRUCT SEWER PER CITY STANDARDS ® CONSTRUCT SEWER MANHOLE TYPE "A" PER C.O.B. STD. SW -4 AND SW -5. ® CONSTRUCT SEWER CLEANOUT PER C.O.B. STD. SW -6. CONSTRUCT STORM DRAIN PER CITY STANDARDS o CONSTRUCT STORM DRAIN MANHOLE TYPE "A" PER C.O.B. STD. SW -4 do SW -5. otr CONSTRUCT CATCH BASIN TYPE "A" PER C.O.B. STD. D-14. W WATER UNE SHOWN AT LOCATIONS OF PIPE CROSSINGS L NOTES : 1) ALL CATCH BASINS ARE TO BE TYPE "A" REVISION WITH 3.5' OPENINGS PER C.O.B. STD. D-14 APPROVED BY. UNLESS OTHERWISE NOTED. ROGER A. McINTOSH R.C.E. 33322_ DATE 2) ALL PIPE ELEVATIONS SHOWN ARE INVERT ELEVATIONS UNLESS OTHERWISE NOTED. SECTION DESIGNATION: SECTION LEVER REVISION APPROVED BY: T)OJ 2 NIEL PADILLA R.C.E. 67008 DATE SHEET WHEN SECTION IS SHOWN ., '&, w SCALE: 1" = 50' 50' 25' 0' 50' 100' Know what's below. 0111 before you dig. } M J N V)o zZ 0 T)o J W Z V) Z J Q a 0 N W t0 Lj a O N SHANAGOLDEN STRE T 1 SEE SHEET 6R IM--- - - - - - - 30' 30' R/W 1 TRACT BOUNDARY R/W 20' 20' 1 2 1 5' -- --� --- oz � aD 5' w 9 $ r rn N p r•> M 1 I J J 1 M O M p. W 0 1 U Z N j 0 O '--- — — — — to C LO II O . 3 '+. Z Z C3 L� > W N O N •p t N M -Z Wj W O O N O J -1 II W N h j_J— Of W L` tp N l N Q > W J 1 Z _ pp 41 1 10 z �w -4 O cfl z ��$ opFO w +00 ago;, �j W C_O UTILITY `4 m M e J o Q ao Q w c H JQ W N N EASEMENT PER - w + + cn o Q D: Q P DOCUMENT N0. LL ± ± ± a cn C-4 o ± < o l±i SI o i Q �m o o ao z� u'z, c' d cc a_ Li Li a z nF 40 WN r� NNZ� V1 N C7N A\ CAP 10' SEWER S B - - _ C I AT TRACT BOUND Y 1 5R- I N885 42 W -10' SEWER 16.1¢' 11+00 _ - 12+00-N885742"W 0' SE, —� - -N 8857'42" W 51 10+00 S 88'5742" E 161.16; N8857 42 W L4 i 8 WATER t8' DRAIN 81.00` " N885742'W 18" DRAM 370 368 366 364 362 360 358 356 354 352 350 348 346 344 342 340 338 336 334 332 330 366 364 362 360 358 356 354 352 350 348 346 344 342 Z Q Z � I � � I Jc � � 1 w A 5R fRAINAGE SUMP SEE SHT. 7 o: Z t5R $ oma- _ M -- AO ��' N M j a V\ Z� % z Q LL L9 r'�Q NT N0. M �I I tri o �- 1 M to 10 L,_ W + j I U + ; N =r- Se `- W U o I c-.43 N fn Z C o i f ' FLOWAGE AND LUU1 DRAINAGE EASEMENT PER DOC.# 000215149026. c z pL c I J I j 1 1= I t= I t= !-! 1:i 1 , J 1 J O J �-' O I g. N o0 0 o 0 1 8 1 TYPICA 8 't . 3. W l o Np I zc l N'00 N, pf p O N I NO '� NO Z��I 42 J - �W ('*D _j ��^W 44 ,^NoJ 45;N46 IN47o-I:1^ 48 I } pQ Z to : N W Q OD 1 ri W = Df 1 .M-iV I Q QNNI 4� �� �U +ar +ao z�^ Oao I zo a I 1 IQ -o 1 Wz ���, �� ap z I Q I �Q+tet �Q 1 cnz ( cn 1 ►-o 1 �0 1 �S ar- Q�I , cnzC 1 cnz 1 cnz 3ddl in TYPICAL CD .T U •r R/W ��i �� Iz �0 1 c>r01 :� �0 1 iro W I O pj Jg0, a3 U pj 00 pj 00 R W tq Map V M 00 I M a^p I F -U_ M o0 I MoD O� ej IS N 06 Lq . � U I. rnoi iuo Iza �P 1 o,Ql z o^ip 1 �Q -ISI d 69 NZ 68 MZ 67 z' 66 Z' N „z' +z64 goo ra' I < I94 a I vtoom� to ( cn 1 �- F- I 6 < ( d ' + + 1 HA SIE 2 I I aN cn -•Aim!— �__H.A 3 ASHE ROAD NAVAN PLACE Q SEE STREET PLANS SEE SHEET 6R (NOT A PART) • ( I TRACT BOUNDARY a 00 JJ a Q u'�- ' �-■� - �� �F -�--� �! ASHE ROAD =a ID Z .0 J p I M •� J 1 J Q ' J I J 1 t I 7 Z S I J, R I I 3-1 + z N� I NOO<Q NO I C4 1 ci 30^ I 30' 0 I: n vii N 1 v'W N a Q 1 v No 1 N 1 ' EXISTING EDGE g 20' , 20' _ rz n i (6W 1 W 52, ^ W 53 I M=, 54 55 OF PAVEMENT o O 5> QOLD O O+ °.° N °D z + + o.° ;o 5• �OD� �Q I .P L 104 I NQ 36.26' I iv~i I �3QQ Nz I Nz j v~iUj z j v~iz Win in In _ 1 R I - 35' WIDE SEWER 00 -� EASEMENT TO BE10 RECORDED WITH - • S o 0 20+00 S N8857'42'W 10" SEWER ?95.29 \ FINAL MAP • z 1 +00 S 8857'42' E 292.59' 21 00 x N54'38'34"W D I 10' SEWER 161.49' SAWCUT CROOM LANE - - _ - _ SEE SHEET 3RSUNCHASE DRIVE (STA. 10+00 C.L. TO 23+34.68 C.L.) SCALE: 1" = 50' HORIZONTAL SOI R/W �o I LF VT PER c MI M 1 0 NT N0. M �I I tri o i _ M Z O W '�'a-0 I R r• E' o c; 1-d I0 o � co, I1 >w LUU1 a I =-1 N 1 z JJ J C; Moo Q dp QV j .- z Uli W W -I LLJ ^_ ±Z62 z 61 � �� m� `60 + I w> - a o z L. , o Q 0 a+0 mml } Ob 0+0 J N to •- I Elm 11.2M �� mal"M11"p-0,18 U N►Q�ow cnW I j CL j W OQ F_ vF► W W W J J J U N N e4j to to z in 1 CROOM LANE - - _ - _ SEE SHEET 3RSUNCHASE DRIVE (STA. 10+00 C.L. TO 23+34.68 C.L.) SCALE: 1" = 50' HORIZONTAL SOI R/W �o I LF VT PER c MI M 1 0 NT N0. M �I 0i I c M t o ^��NI �p 1 W '�'a-0 I 59 m_' S8 0=' 57 Nz I I N W-� a I d I N I N 1 N I A 1 o 00 00 Icn PHASE BOUNDARY �' OVER GRADING LIMITS TEMPORARY FLOWAGE AND DRAINAGE EASEMENT PER DOC�j Ob2T57: " - 11. J 1 N to R i oW3 CONNECT TO I z • N EXISTING 30" 1 SEWER MAIN j 56 =^r II I QN , rnrn + + I I jr 04 N I o -- -----i �3'dQ cow (A v) v~i o a0 J z d V — — 0 i +p d� QNN co Z I`- TEMP. SUMP i , O r) xSEE SHT. 7 i N N Lj " / Nom( la STORM DRAIN LINE TABLE UNE SIZE BEARING DISTANCE L1 18" N 1'01'46' E 56.61' L2 18" S 45'32'44" W 37.80' L3 18" S 1928'24" W 15.81' L4 18" S 885742' E 42.75' L5 18" N 1'02'18" E 25.00' L6 18" S 17.2348' E 15.81' SEWER LATERAL LINE TABLE UNE SIZE BEARING DISTANCE L7 4" S 16'14'02" W 51.41' L8 4" S 10.30'48" W 48.57 INSTAI L 15.81 LF OF 18 RGJ-F CP co OR O N W-� Al 000 0 o 00 00 SEWER LATERAL LINE TABLE UNE SIZE BEARING DISTANCE L7 4" S 16'14'02" W 51.41' L8 4" S 10.30'48" W 48.57 INSTAI L 15.81 LF OF 18 RGJ-F CP 10+00 11+00 INSTAI L 15.81 LF OF 18 RGJ-F CP co OR O N W-� Al 000 0 o 00 00 10. j .- Z-- ­Eln „ �� zz U z_j OZ w> - a z 0 L. , o Q 6 LnMiO mml +MMM z Elm 11.2M �� mal"M11"p-0,18 U cnW I j CL j W OQ F_ W W W J J J U O W NONE WWW l m -m mmmmmmmmm y � immium m 'MEIN IN RT 18' DRAIN mvllmw�lmm mmmmmmmmmm IN N ME m ONERNMEN1- U-1 ME mmmmmmmmm m � A�■t■finmmmmmmmmmm MEER NEW 11 -p- ME m I-EMEMEMENEEN m ME m�EMENEENE MEN m mj1mi,300mmmmm mmmv- ME m m Em.. l%kEEEE NEON MENEM m MENEENE m MEN ME m 0 m 111 mimmmmmmmm m a 0 m m E ummem Mae won CONTRACTOR TO HAVE SURVEYOR AND INVERT STUB -.NMI .-IBACKFILL � � IIIA .�� MENNMASEWER �� NA 10+00 11+00 Aj( V(!j6LE: SECTION 1"= 50'HORIZ.1" = 5' VERT. 12+00 13+00 366 EE NOTE 'CC ZE 368 ac64 366 -362 364 360 362 358 360 356 358 354 356 352 354 350 352 348 350 346 348 344 346 342 INSTAI L 15.81 LF OF 18 RGJ-F CP co OR O N W-� Al 000 0 o 00 00 10. j .- Z-- ­Eln „ �� zz U z_j OZ w> - a z 0 L. , o Q 6 LnMiO mml +MMM z Elm 11.2M �� mal"M11"p-0,18 U cnW I j CL j W OQ F_ W W W J J J U O W v) WWW l m -m y � immium 'MEIN IN RT 18' DRAIN mvllmw�lmm IN N Aj( V(!j6LE: SECTION 1"= 50'HORIZ.1" = 5' VERT. 12+00 13+00 366 EE NOTE 'CC ZE 368 ac64 366 -362 364 360 362 358 360 356 358 354 356 352 354 350 352 348 350 346 348 344 346 342 B SECTION Q 5R SCALE: 1" = 50' HORIZ. 1" = 5' VERT. __L4+_Q0 15+00 368 NOTES: CC: STORM DRAIN LINE TO BE CONSTRUCTED Q WITH PHASE 1, CATCH BASIN STRUCTURES 366 IN PHASE 2 SHALL BE CONSTRUCTED WITH PHASE 2, PLUG DRAIN LINE ® END FOR 364 FUTURE CONNECTION TO CATCH BASIN. DD: SEWER MAIN LINE AND LATERALS TO BE CONSTRUCTED WITH PHASE 1. 362 EE: OUTLET STRUCTURE TO BE CONSTRUCTED WITH PHASE 1. 360 LEGEND: 358BA BREVIATIONS CL CENTERUNE SMH SEWER MANHOLE INV INVERT SCO SEWER CLEANOUT 356 SD STORM DRAIN SDMH STORM DRAIN MANHOLE MH MANHOLE EXIST EXISTING CB CATCH BASIN ELEV ELEVATION 354 JB JUNCTION BOX R/W RIGHT OF WAY SCP STREET CONSTRUCTION PLAN 352 r O.M.363.22 TOP OF MANHOLE/TOP OF CLEANOUT ELEVATION 350 —S—CONSTRUCT SEWER PER CITY STANDARDS 348 ® CONSTRUCT SEWER MANHOLE TYPE 'A" PER C.O.B. STD. SW -4 AND SW-& 346 ® CONSTRUCT SEWER CLEANOUT PER C.O.B. STD. SW -6. 16+00 17+00 18+00 19+00 OTF " /,\20+00 21+00 (STA. 10+00.00 TO 23+34.68) 36 SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL 36 36 36 36 35 CONSTRUCT STORM DRAIN PER CITY STANDARDS o CONSTRUCT STORM DRAIN 35 MANHOLE TYPE 'A' PER C.O.B. STD. SW -4 do SW -5. oir CONSTRUCT CATCH BASIN 35 TYPE 'A' PER C.O.B. STD. D-14. 35 W WATER UNE SHOWN AT LOCATIONS OF PIPE CROSSINGS 35 NOTES : 1) ALL CATCH BASINS ARE TO BE TYPE "A" WITH 3.5' OPENINGS PER C.O.B. STD. D-14 3 UNLESS OTHERWISE NOTED. 2) ALL PIPE ELEVATIONS SHOWN ARE INVERT ELEVATIONS UNLESS OTHERWISE NOTED. 34 SECTION DESIGNATION: SECTION LEM 34 8Iwo INSTALL 5.00 L OF 187 GJ -RCP 6 0 011% r 4 0 V) z W Z3 2 •a W a x R o _ r- • > z » > o l� Z Q zzz w z '7, z 'OD 14 8 < 00 Ix �CD� z = M M M M w ~ W O WWW >> 6 U W in W W W t oM' 4 _ �- 2 0 ' � I VERT 16' AIN 6 NWRT 4 10' SEWER 368 370 n 366 368 364 366 362 364 360 362 358 360 356 358 354 356 352 354 350 352 348 350 346 348 344 ■ -MnEM 2 C SECTIOND SECTION Slit WHERE SECTION IS SHOWN � 5R SCALE: 1" _ 50' HORIZ. Q 5 SCALE: 1" _ 50VERT. ' J 1 — 5 VERT. 22+00 370 368 366 364 362 360 358 356 354 352 350 348 23+00 .� REVISION APPROVED BY: ROGER A. McINTOSH REVISION � APPROVED BY:)0j DANIEL PADILLA 370 368 366 364 362 360 358 356 354 352 350 348 346 344 342 340 338 336 334 332 330 Know what's below. Call before you dig. SCALE: 1" = 50' 50' 25' 0' 50' 100' 1 R. 33322 DATE d ---a7-(6 R.C.E. 67008 DATE M J N Zvs Zo 2 z V� w Z W z N Q 2 a W W 0 N INSTAI L 15.81 LF OF 18 RGJ-F CP co OR O N W-� Al 000 0 o 00 00 .- j .- „ �� zz U z_j OZ w> - a z 0 L. , o Q 6 LnMiO mci +MMM z m+ 11.2M �� U cnW I j CL j W OQ F_ W W W J J J U O W v) WWW y � IN RT 18' DRAIN B SECTION Q 5R SCALE: 1" = 50' HORIZ. 1" = 5' VERT. __L4+_Q0 15+00 368 NOTES: CC: STORM DRAIN LINE TO BE CONSTRUCTED Q WITH PHASE 1, CATCH BASIN STRUCTURES 366 IN PHASE 2 SHALL BE CONSTRUCTED WITH PHASE 2, PLUG DRAIN LINE ® END FOR 364 FUTURE CONNECTION TO CATCH BASIN. DD: SEWER MAIN LINE AND LATERALS TO BE CONSTRUCTED WITH PHASE 1. 362 EE: OUTLET STRUCTURE TO BE CONSTRUCTED WITH PHASE 1. 360 LEGEND: 358BA BREVIATIONS CL CENTERUNE SMH SEWER MANHOLE INV INVERT SCO SEWER CLEANOUT 356 SD STORM DRAIN SDMH STORM DRAIN MANHOLE MH MANHOLE EXIST EXISTING CB CATCH BASIN ELEV ELEVATION 354 JB JUNCTION BOX R/W RIGHT OF WAY SCP STREET CONSTRUCTION PLAN 352 r O.M.363.22 TOP OF MANHOLE/TOP OF CLEANOUT ELEVATION 350 —S—CONSTRUCT SEWER PER CITY STANDARDS 348 ® CONSTRUCT SEWER MANHOLE TYPE 'A" PER C.O.B. STD. SW -4 AND SW-& 346 ® CONSTRUCT SEWER CLEANOUT PER C.O.B. STD. SW -6. 16+00 17+00 18+00 19+00 OTF " /,\20+00 21+00 (STA. 10+00.00 TO 23+34.68) 36 SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL 36 36 36 36 35 CONSTRUCT STORM DRAIN PER CITY STANDARDS o CONSTRUCT STORM DRAIN 35 MANHOLE TYPE 'A' PER C.O.B. STD. SW -4 do SW -5. oir CONSTRUCT CATCH BASIN 35 TYPE 'A' PER C.O.B. STD. D-14. 35 W WATER UNE SHOWN AT LOCATIONS OF PIPE CROSSINGS 35 NOTES : 1) ALL CATCH BASINS ARE TO BE TYPE "A" WITH 3.5' OPENINGS PER C.O.B. STD. D-14 3 UNLESS OTHERWISE NOTED. 2) ALL PIPE ELEVATIONS SHOWN ARE INVERT ELEVATIONS UNLESS OTHERWISE NOTED. 34 SECTION DESIGNATION: SECTION LEM 34 8Iwo INSTALL 5.00 L OF 187 GJ -RCP 6 0 011% r 4 0 V) z W Z3 2 •a W a x R o _ r- • > z » > o l� Z Q zzz w z '7, z 'OD 14 8 < 00 Ix �CD� z = M M M M w ~ W O WWW >> 6 U W in W W W t oM' 4 _ �- 2 0 ' � I VERT 16' AIN 6 NWRT 4 10' SEWER 368 370 n 366 368 364 366 362 364 360 362 358 360 356 358 354 356 352 354 350 352 348 350 346 348 344 ■ -MnEM 2 C SECTIOND SECTION Slit WHERE SECTION IS SHOWN � 5R SCALE: 1" _ 50' HORIZ. Q 5 SCALE: 1" _ 50VERT. ' J 1 — 5 VERT. 22+00 370 368 366 364 362 360 358 356 354 352 350 348 23+00 .� REVISION APPROVED BY: ROGER A. McINTOSH REVISION � APPROVED BY:)0j DANIEL PADILLA 370 368 366 364 362 360 358 356 354 352 350 348 346 344 342 340 338 336 334 332 330 Know what's below. Call before you dig. SCALE: 1" = 50' 50' 25' 0' 50' 100' 1 R. 33322 DATE d ---a7-(6 R.C.E. 67008 DATE M J N Zvs Zo 2 z V� w Z W z N Q 2 a W W 0 N 368 370 n 366 368 364 366 362 364 360 362 358 360 356 358 354 356 352 354 350 352 348 350 346 348 344 ■ -MnEM 2 C SECTIOND SECTION Slit WHERE SECTION IS SHOWN � 5R SCALE: 1" _ 50' HORIZ. Q 5 SCALE: 1" _ 50VERT. ' J 1 — 5 VERT. 22+00 370 368 366 364 362 360 358 356 354 352 350 348 23+00 .� REVISION APPROVED BY: ROGER A. McINTOSH REVISION � APPROVED BY:)0j DANIEL PADILLA 370 368 366 364 362 360 358 356 354 352 350 348 346 344 342 340 338 336 334 332 330 Know what's below. Call before you dig. SCALE: 1" = 50' 50' 25' 0' 50' 100' 1 R. 33322 DATE d ---a7-(6 R.C.E. 67008 DATE M J N Zvs Zo 2 z V� w Z W z N Q 2 a W W 0 N 2 C SECTIOND SECTION Slit WHERE SECTION IS SHOWN � 5R SCALE: 1" _ 50' HORIZ. Q 5 SCALE: 1" _ 50VERT. ' J 1 — 5 VERT. 22+00 370 368 366 364 362 360 358 356 354 352 350 348 23+00 .� REVISION APPROVED BY: ROGER A. McINTOSH REVISION � APPROVED BY:)0j DANIEL PADILLA 370 368 366 364 362 360 358 356 354 352 350 348 346 344 342 340 338 336 334 332 330 Know what's below. Call before you dig. SCALE: 1" = 50' 50' 25' 0' 50' 100' 1 R. 33322 DATE d ---a7-(6 R.C.E. 67008 DATE M J N Zvs Zo 2 z V� w Z W z N Q 2 a W W 0 N �1 SUNCHASE DRIVE Q SEE SHEET 5R 1 TRACT BOUNDARY �ss�� sisfs+_E�s�s�f�s s�sff�E •��ff�� sof• •;sisfr� sf,•Eff fs��ff���f �s�ff�Ess�� N � � Q N 1 I Q I , I n 00 o ILZ� L'o PHA 2 tD •� I I z �Z qWa �i w c Ura W 0 Ld 7b I t= I ( 3 ►= ao Z ,W 1 I 1 I_ J ( J I I I C�� 1 J n I J , II 1 fm U in C3 N O 2 O ' Z C0.9 O O ^ W I ( O n O ��i1 O W VlN (9N �,N 3 O 4 O Q Z 5 O ' O 6 O 3 g M tp Z W , Q J - o ,� cc oW p N CA o 6' a 0i o of ' v z W ori � z Q S� y 0 0i O O p -1tn�p -ANO ON NO NO I NO Im NO NO (n CAO 7 I MM 8 W / QJ Z. 0 _Z �- _ O O CL Q ai ri 3 1 N ci 0i _j � p CA 4 _- N of tc 3 O- 0 N 9 Z 0 o G d O a t0= g I 1� N ( 1� N I Gj N O N O a O . J Q' _ ++ I'� �WccQW o-dNI ,�j3 I d 3 I m3 I�UU ui3 , crj3 = 01 ON 1 ^vN Z _jJ Q O ip m m Cr ^ ^ N N a0 tV N O Oac-4 t0 = Z • O I O 3 ( j� Q N I U C3 W 0: add �Q� V) +d I +.r .+1* 1=SO � Q O NN �+ z F� rr��� Qao =� UCC �- �. F } .f Q�j 0000 - V)o00 r J 3 . Q to � N N to to � Z !n •- I + o ! � !n � ^� � I co Er. V o o ' M ti cwi� v~i z I 1 �a-W 1 Q0000 1 fQ000 0 i � <0000 ►Q0°Oo a� Nz 'Q. ++ Z I M 1 �z vriz <nZ vriz I V) 'al r00 1 r cno I 1 L I z a d 1 W r, z 1 � to - i- a CL l 0 0 -�_- --�-- � vrivri rn m dad =0+�-+ - --� X6 63' uri cn /z cr I Q m � "�� I - M 11+00 N01*02'18"E S 6' SEWER 39 -♦68:89= S 13+00 �_� '�' o �n L1 5\� ` z - N 1'0218 E 270.00 - - - - I-- - LLJ N 1'02'18" E 270.00' Z U w I o S01102'18"W 18" DRAIN -6;5.68' 2+00 14+00 _ Q 0 .00 N \ M W t,_ 0 0 � 1 !? m m `r 4 o Z H I Z 'sem it -+-JN = I I I 3 C.> -- --�� -- -j - -- -- o /8' s�� 5� as ii z J Z200 H J R/W I / 1 r r O W < .. to U R/W om \ 'pq6'S0 cn z Q ' Q. Z W �:_ q ' I , W I S.9 11 x ¢ N mo 8W I 26 25 -- -enz 40 39 1 Ix N Z-3 -BOO CSD LU O =Z I ( 3 I"^ ( M I IN N N O co O N N , }I z- d' 30' I 30' N �� -- -- 1 -- -- --� `� Ito °vg F------ -- i o• w ' 12 20' 20' 1 0 C1 I 1 5' 1 Q -- -- -- -�' m N to 5' r SEWER LINE TABLE UNE SIZE BEARING DISTANCE L1 6" N 1'02'18" E 120.00' L2 6" N 45.44'33' E 45.20' L3 4" N 31.3753" W 47.52' L4 4' N 41'16'53" W 24.74' L5 4' N 8104'01' W 22.18' STORM DRAIN UNE TABLE UNE SIZE BEARING DISTANCE L6 18" N 88'57'42" W 25.00' L7 18' N 88'57'42" W 15.00' L8 18" N 8857'42" W 25.00' L9 18" N 8857'42" W 15.00' 0 Z i� N R/W [lid J C3 n �cn `SUN HA E DRIVE 9BANR PLACE Q TU LIANE Q SEE SHEET 5R EET 4R T 3R Uj 1 U , Q TYPICAL SEE NOTE FF � N -J W W 35V C 22 18 �rR� 0 !j fA J d'M 1 IW o W�, 49 ,N J _ ( 13 '" o �n = 1 I N o Z � J "�> _ - U -_ -- � � __ _- _---�---1Zg N1c'4 �r'n`% I O I� � � � l y io U LA - 30' W a R/W I I v°g I -r R/yy I ori M y^ M n 30' 30' ? 'cri to i r J o _qj I�. �1 100 Q^ n �`' z w I 30' 30' ( < v Z U w W 1 I °� �-� > m f: � J a z M I c[i w 30' 30' C p. ���tg7f �_+ 34 N Lq 20 2 5 o o a W+ Q 20' 20' 8' WATER 2 I �" 1 9 0° M aN, W 20 20' 1 z o W I Q moo: r o+ ++JN 5' N o 5 N z o N 5 0 H R/W 5 R/W � < r��� m�� WO 12 U Q Q d 2 + N S01'02'18"W - �_ _ _ _ _ _. - cri> ci - c� ci c i z o I I rU- 'r < w I ' U dna I 18' DRAIN ^ o o $05'2605 E c� vri z o 52.75' -' M 11+00 12+00 SOt'02'18"W 8" DRAIN 444.50' �' "' 14+00 18" RAIN 6 .19' -- -- J - -+- - - - I -- 8 - - --{ - S - - - - ; S "' co N01"02'18 SEWER 260.00' 13+00 0 11 o N N01'0218 E 8 SEWER 270.00' 000 15+003 6R c R/yy W �, R/W a w M II o ,n 1 Ia J 1 B� 8' WATERr� -- ' 3 m N M. rn'' I ii o- 1 1 > Q wl Z /9\ _ M> �Z •� W ,. 0 _ GR 0Ui Z� �I y�yy,,,��� JpUi 0/ 1 \LZ- C)li W W J Z .� 1 �Z 24 IM oM 1 ''�nW ip W = .0 Q ^^WN a W Cn ' ZQ N M> (7J3 N C.UV 10 m I zJ0W 04 51m �nv�c F- O '0 30' NI 30' I -4J IZ Cj�jW Ld �-o ^�5 ooJW _- __ -Z 'mJ 20' 20' zUU -- �cicnw� Opo N sr I Nv30'I QyNj + 1 5' F ,�- -- Q "c'! w_- __-=c!q IkLi 1( 1 30' U Q d W N I U O �m CA 0, ti w ZQ r) M to I m •- 2(Y 20' � ta- C -Y 1;; 'cn- I I 1 aN� � aN M+tn Lo c0n0 -~� --- I 5' �'32 U •W zaa 25 < ��oW 3Qa in cn I 5' h U 20' 20' I A. TYPICAL I -- I I v i c-� cn cn z 0 2 W r r oQ Q (n V) in I I I 5 � $ + � 30 30 1 I 20' N 20' L.. _ _ - - - m 'v 52 I I 1 I 30' 30' I 41 3 Q 30' 30' I I - - - _ - _ RjW I R/W 1 I 20' 20' ? N I (� R/W" I � R/W 2 7 PHASE 2 1 I NOTES: i R/W -�- - - - - --I -- - - -�--- -- -- --•� 5 �UNCH D IV 1 BANGOR PLACEI 1 CC: STORM DRAIN LINE TO BE CONSTRUCTED SUNCHASE DRIVE BANGOR PLACE 1 TULIA LANE SEE SHEET 5R 1 SEE SHEET 4 TULIA LANE WITH PHASE 1, CATCH BASIN STRUCTURES SEE SHEET 5R__/ SEE SHEET 4R �EE SHEET 3R Al .._`�,..�D SEE SHEET 3R QIN PHASE 2 SHALL BE CONSTRUCTED WITH SHANAGOLDEN STREET PHASE 2, PLUG DRAIN LINE ®END FOR FUTURE CONNECTION. CONSTRUCT WITH CONSTRUCT WITH (STA. 10+00 C.L. TO 15+40.00 C.L.) DD: SEWER MAIN LINE AND LATERALS TO BE _ PHASE 1 -__ PHASE 2 017 "R GJ CP 18"--R -PCP CB CATCH BASIN ELEV ELEVATION : = SCP STREET CONSTRUCTION PLAN 1 00.1% TOP OF MANHOLE/TOP OF CLEANOUT ELEVATION S CONSTRUCT SEWER PER CITY STANDARDS ® r M TYPE 'A' PER C.O.B. SM. SW -4 AND SW -5. ® CONSTRUCT SEWER CLEANOUT azo PER C.O.B. STD. SW -6. 370 W -- Z IR M W Z 3 W t M 3 n) 0 �� raj j00 N ii jW W Z z INSTALL 20 LF O .1 C0.11 1%RGJ-4RCP � W 368 ---WITH PH 18- -- - -- -- - ;----- ----- M _I W Cf r5 5.00 z U) -I W Of 0 M N - M M m* VL N OD INSTALL 69.24 LF OF 18" 368 J QNM W U .;k= ' Coe. '_� O W J LL. EL W W Q U Z 13 W N W U Z � W I I- cn I STALL\ c OF 1" RI J -RCP 410.11% I ROJ-RCP 4 0.1174 INVERT 8 DR-AINRei 366 I -- ---- -L- cn 366 , W j Q C5 a o 00M3 364--- { z �n--Z -- - ----- -- - - - -- _ Z 0 W Wzcn ao N n 364 0 00 00 W �`00 j o z °0 °p M j 00 - -362 362a z zz g � oJ Z W _ - Z M�tpiM 360 - - -«� WUU> �, �_- ; ---- -- - ---f----- - Z 'n O d Z c+- 00 360 D' 1� 00 t� I^ +I Z O O J� LL o MMM m + `` M M M IM _ 358 -- --- ; (Q� >�t> � Mm � -o---=- -- ---- --- - , • = Q WM 358 (>� F J < I OM I ( O "'�J J Q O W J _j _j N W W W�W 356 mVW� �j W-- -- tcn�NW - -- -�--- GR A TERUNE -- - c ' � (n W W W `�' OS1.0.M U �z O W 356 a-- -- ---- -- 6�0 354 -- - -- - I -_ --- -- - - -- - =-- - - - ---- - - -- - - - - - - - - 3' 354 352 - - - I - 352 -- ------ 350 4 350 --- - - - - - - - - -: 348 ---� __7348 INV. 18" DRAIN INVERT ;18 DRAT , INVERT 6. SEW 6 " SEWER 346 - - -• - ---- - -- - -----�--- • - • 346 -- i ' f iINVERT 6. 'EWER 18" AIN 344 -----I - -- - - �r V.- » __S; tj _-- {--- `-� 3 344 O N to Z - -- - -- 342- 0 = Z--- oz a 0 -- -- - --- -- C - - - •a Z J tD t� a 342 340 - - - - W�> >- Z-- -- Z i - -- ---- a m .zz - - - - j z 340 - Z © JZ 0- a0 Om 0 Ui 'n 0 UZ O Q N F O M 338 - - - - 0 °�- z,4 + - = ---- - -- -a--- --� - - O .. pip Q�p 0; + 338 i O N } MM • + d A M m� 336 � . > -� � � W ----- --------�----- - d M ►�'1 SQ W W J 336 N W W W LL 1 Q LL W W w INSTAL LF 334 - _ --- -- -- ---- ----- --- -- ---- t "45.20 334 INSTALL' 10 LF OF INS ALL LF OF 6 " PVC ® 0.61% 6 " PVC 1.00% 1.00% - - --- -- --- - - -- -- ----- j 33 07 Pi�P -0.61 332 CONSTRUCT WITH CO STRUCT WITH - - = PHASE __-PHASE- ---------'---- - 12+00 13+00 - 14+00 15+00 16+00 9+50 1 00 11+00 368 368 INST L 15.00 LF INSTALL 2.00 LF OF 1 RGJ-RCP OF 18" RGJ-RCP 366 I 366 364 - --- - o-- - - --- 364 z3wcn W 1 CO W a a:: ` M • � a O M aoo-m too 00 Al ,Mq Il a 362 - M .- •- - -- M -s 362 J Q jtj j = �zzZ �+- >Wj Z _ _ - 0 W IL 1��0 W Z _s- J. J_ i2 =,,, ;� w a 'M=��M, Z W� 360 • -I 0 F- < 1' 06 00 m m O to -i p rn 358 rm.M z -+ ;��' w . QOM 358 U .M j wcn. Otwww cn i2w>; Z - W 356356Z g 354 ----- -- �_ �--�'0.11•-'�----�---- 354 352 --- - r --------- --- 352 t j 350 -- - -- ^ - - j -- - -- -� 350 I � � 348 -INVERT -- - - - - - --� 348 8' DRAIN INVERT 1$ DRAIN 346 ----- -- .-- ---t--------- -- ----- -- 346 I 344 344 INVERT �! j 8. SEWER I A SECTION Q 6R SCALE: 1" = 50' HORIZ. 1" = 5' VERT. (STA. 10+00.00 IU 15+40.00) SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL 370 368 366 364 362 360 358 356 354 352 350 348 346 INST LL 15.0 LF INSTALL 25.00 LF1 017 "R GJ CP 18"--R -PCP CB CATCH BASIN ELEV ELEVATION 00.117, SCP STREET CONSTRUCTION PLAN 1 00.1% TOP OF MANHOLE/TOP OF CLEANOUT ELEVATION S CONSTRUCT SEWER PER CITY STANDARDS ® r M TYPE 'A' PER C.O.B. SM. SW -4 AND SW -5. ® CONSTRUCT SEWER CLEANOUT azo PER C.O.B. STD. SW -6. -- W -- Z IR M W Z 3 W t M 3 n) 0 �� raj j00 N ii jW W Z z IM N - Z- W J Z --Z Z W J Z M _I W Cf Q -01 bD ' QA Op ,0 • z U) -I W Of 0 M N 0 M M m* VL N OD altn M _ J QNM W U .;k= ' Coe. '_� O W J LL. EL W W Q U Z 13 W N W U Z � W I I- cn I c Q I a f INVERT 8 DR-AINRei - I -L- B SECTION Q6R SCALE: 1" = 50' HORIZ. J 1" = 5' VERT. 370 368 366 364 362 360 358 356 354 352 350 348 346 LEGEND: CONSTRUCTED WITH PHASE 1. FF: CURB & GUTTER AND CATCH BASIN TO BE CONSTRUCTED WITH PHASE 1 (SEE _ ALSO STREET PLAN). 368 -- T 366 --- - �; o 364 - - - -- w O 0 362 --- I 360--- . ! � 358 - -- ' O N 356- 354 - - 352 !---- -j - 1 350 --- - - -' 348 --- --� - j 346 -- - - I 344 C 342 -- - I 340 -- - 338 -- --� - i I i 336 -- - -- - 334 --- - I 332 - - 9+50 CL CENTERLINE SMH SEWER MANHOLE INV INVERT SCO SEWER CLEANOUT SD STORM DRAIN SDMH STORM DRAIN MANHOLE MH MANHOLE EXIST EXISTING CB CATCH BASIN ELEV ELEVATION JB JUNCTION BOX R/W RIGHT OF WAY SCP STREET CONSTRUCTION PLAN T 0 M. 363.22 TOP OF MANHOLE/TOP OF CLEANOUT ELEVATION S CONSTRUCT SEWER PER CITY STANDARDS ® CONSTRUCT SEWER MANHOLE M TYPE 'A' PER C.O.B. SM. SW -4 AND SW -5. ® CONSTRUCT SEWER CLEANOUT azo PER C.O.B. STD. SW -6. FAI SE' E NOTE _FF'_ FOR THIS NAVAN PLACE (STA. 10+00 C.L. TO 15+40.00 C.L.) SCALE: 1" = 50' HORIZONTAL 10+00 11+00 12+00 13+00 14+00 15+00 (STA. 10+00.00 TO 15+40.00) SCALE: 1" = 50' HORIZONTAL SCALE: 1" = 5' VERTICAL CONSTRUCT STORM DRAIN PER CITY STANDARDS ® CONSTRUCT STORM DRAIN MANHOLE TYPE "A" PER C.O.B. STD. SW -4 & SW -5. CONSTRUCT CATCH BASIN TYPE "A' PER C.O.B. STD. D-14. w WATER UNE SHOWN AT LOCATIONS OF PIPE CROSSINGS NOTES : 1) ALL CATCH BASINS ARE TO BE TYPE "A" WITH 3.5' OPENINGS PER C.O.B. STD. D-14 UNLESS OTHERWISE NOTED. 2) ALL PIPE ELEVATIONS SHOWN ARE INVERT ELEVATIONS UNLESS OTHERWISE NOTED. SECTION DESIGNATION: SECTION LETTER _2 SHEET WHERE SECTION IS SHOWN REVISION APPROVED B . ROGER A. REVISION APPROVED BY: _ D '40 0, PADILLA SH R.C.E. 33322 DATE R.C.E. 67008 DATE 9 LF OF 00 18" b. = N N LO Q cn N, ' Q M in O z J ,Z z- W ' iV + J M M zZ Q azo • W U Z W 3 V� 0 LU t to Z Q� c� r 0 t0 00 Zz tC �to M try LU Lj W W W rn 0 M H � Q U x I- Z OL I Q J W U 00 00 J .- W 0 o N (Y. U.1 Y Q 368``' b. = N V 366 Q V M , ' Q 364 o U �z �P 362 0 ot$ 360 < 0 358 356 354 352 350 348 346 344 342 340 338 336 334 332 16+00 SCALE: 1 " = 50' 50' 25' O' 50' 100' Know what's below. 0111 before you dig. .2-6663 Ph 1 & 2 Rev CITY RECORDS NO: y M _=1 N V Q CO J z a. J Z a. Q �o Z � N Q a Z 0 ot$ O Uo co Z zZ aw azo ~ Q j �o W O♦R 3 V� 0 LU to Z Q� c� r 0 W o' z Q W Z cn Q a 0 cn W cc a o W V Q CO J z a. J Z a. Q Z � N Q a Z 0 ot$ O Uo co Z aw azo ~ Q j �o W O♦R 3 V� LU to Z Q� c� NOTES- Z� CC: STORM DRAIN7BE ONSTRUCTED ■ WITH PHASE STRUCTURES - - - - - - - IN PHASE 2 TRUCTED WITH PHASE 2, PLUG DRAIN UNE 0 END FOR ■ FUTURE CONNECTION TO CATCH BASIN. I EE: OUTLET STRUCTURE TO BE CONSTRUCTED ' ( �NTH PHASE 1. g SUNCHASE DRIVE TRACT BOUNDARY ■ I ■ I ■ PHASE BOUNDARY 354.1 FG ...�-�x-■�..�- � �s /CONSTRUCT CHAIN LINK GATE g ' ��5� PER C.O.B. STD. DET. D-13. cli 00-a-0 �" 4 5 FG N8O '"ll, 6'W 81.00' J\ -------------------- L5 1200" 355. FGf k------ A 100 � ' W TRACT BOUNDARY N I 1 I I I p I O I o I I N Lo W c Q I i 3 3 I I I I Q I I N I I 9�G i y9l I L6 A ' 7 ' I I 2.1 I I I 3 I � I � �I o� � I DRAIN SEE NOTE 'CC' Q -j _ 7 s � I S89'46'42'W 45.18' -� `�� ! FLOWAGE AND o DRAINAGE EASEMENT PER CONSTRUCT OUTLET ��' I DOC./ 000215149026. STRUCTURE PER C.O.B. SEE N •E' i FG STD. DET. D-11. I A •,,�' 355,6 EG I Q ' 1200' CONSTRUCT 6' HIGH CHAIN LINK FENCE 1 WITH REDWOOD SLATS PER C.O.B. STD. 2:1 DET. D-12 RETENTION BASIN UMP) VOLUME REQ'D: 1.54 AC. FT. VOLUME PROVIDED: 1.91 AC. FT. D.W.S.: 350.00' BOTTOM ELEV.: 342.00' M w 3 0 .ug n F: z 2:1 DESIGN WATER LEVEL S89'01'10"E 59.57' W 04 I � i ----------------- i I I 354.i I S88'57'46'E 81.00' S88 57'46"E r - DRAINAGE SUMP SCALE: 1" = 20' 20' 10' 0' 20' 40' O 0 N w OD 04 P O Z 355.3 ---A SUMP NOTES: 1. SUMP TO BE CONSTRUCTED PER COB STANDARDS D-11, D-12, AND D-13. 2. THE DRAINAGE BASIN SHALL BE OVER EXCAVATED TO A DEPTH OF 22 FEET BELOW EXISTING GRADE (ELEV. 331.42) AND BACKFILLED TO AN ELEV. OF 342.00 WITH CLEAN COHESIONLESS SAND CLASSIFIED AS SP OR SW IN THE UNIFIED SOILS CLASSIFICATION SYSTEM TO ENSURE ADEQUATE PERMEABILITY FOR WATER TO DRAIN IN SEVEN DAYS OR LESS. A SOILS ENGINEER IS REQUIRED TO BE ON SITE DURING CONSTRUCTION OF THE SUMP. 362 360 358 356 354 352 350 348 346 344 342 340 338 UNE TABLE UNE BEARING DISTANCE L1 S 43'5744' E 21.21' L2 N 46'02'16" E 21.21' L3 N 43'57'44' W 21.21' L4 S 1'02'18" W 15.00' L5 N 88'5746' W 15.00' L6 N 88'56'28' W 15.00' A RETENTION BASIN 7 SCALE: 1" = 50' HORIZONTAL 1" = 5' VERTICAL PhASE 2 6' TA LL CHAIN LINK FENCE c , r WITH C. 0.* REDWOOD STD. SLATS PI R . D-12 I r I I � I I i 1 i r EXISTI G A 12.00' ESS 0 1 I r 1 r 12,00! ACCESsROAD i r I r I I � r 7 Z S=200X 362 ,r VOLUME REQ'D: 0.05 AC. FT. r TEMPORARY FLOWAGE i i�DRAINAGE EE BOA D 1 360 S=200 i BOTTOM ELEV.: 353.75' r 358 ' r rr I I 356 ELE V. 350.0 1 � i I 354 I r � r I , 352 DESIGN I ATER I c r 350 r 55 3 FG tSS.i F r r _ r 348 38' LEVEL 344 342 TEMPORARY SUMP DETAIL 340 SCALE: 1 " = 10' 338 REQUIRED VOLUME: 0.05 AC -FT AREA: 0.35 AC, C=0.95 VOLUME REQUIRED: 0.15 X (0.33) = 0.05 AC -FT PROVIDED VOLUME: 0.06 AC -FT A(BTM): 0.03 AC; A(MID): 0.04 AC; A(TOP): 0.05 AC )ELEV. 34 2.00 1.5' DEEP SUMP - NO FENCE REQUIRED R _ 53' 5.65' z A RETENTION BASIN 7 SCALE: 1" = 50' HORIZONTAL 1" = 5' VERTICAL It B SUMP TO EXISTING GROUND 7 SCALE: N.T.S HIGH CHAIN LINK ]VCE WITH REDWOOD SLATS 3? C.O.B. STD. DET. 0-12. EXISTING G_ROLNVD_ EXISTING GROUNG 2 C TEMPORARY SUMP SECTION 7 SCALE: N.T.S 2 EXISTING I I EXISTING GROUNG GROUNG 1� U-) �1 2 2 D TEMPORARY SUMP SECTION 7 SCALE: N.T.S .A REVISION APPROVED BY. ROGER A. McIN REVISION APPROVED BY: � a DANIEL PADILLA 1Z -/q ,/4 R.C.E. 33322 DATE R.C.E. 67008 DA1 EXISTING GROUNG ` M z V m PhASE 2 Pf-h`44 SE 3 355.3 FG �SS3F % r c , r I I r I r I r I I � I I i 1 i r I , I , V) 1 , ' 2.1 2.1 r 1 I r 1 r i r I r I I � r 7 Z TEMPORARY SUMP I 362 ,r VOLUME REQ'D: 0.05 AC. FT. r TEMPORARY FLOWAGE i i�DRAINAGE VOLUME PROVIDED: 0.06 AC. FT.i EANDAS r EASEMENT PER 360 D.W.S.: 355.25' I ; DOCJ 000215149027. i BOTTOM ELEV.: 353.75' r 358 ' r rr I I 356 ' 1 � i I 354 I r � r I , 352 G 8E , I c r 350 r 55 3 FG tSS.i F r r _ r 348 38' 346 344 342 TEMPORARY SUMP DETAIL 340 SCALE: 1 " = 10' 338 REQUIRED VOLUME: 0.05 AC -FT AREA: 0.35 AC, C=0.95 VOLUME REQUIRED: 0.15 X (0.33) = 0.05 AC -FT PROVIDED VOLUME: 0.06 AC -FT A(BTM): 0.03 AC; A(MID): 0.04 AC; A(TOP): 0.05 AC VOLUME PROVIDED: 1/5 X (0.03+(3X(0.04))+0.05) X 1.5 = 0.06 AC -FT 1.5' DEEP SUMP - NO FENCE REQUIRED R _ 53' 5.65' It B SUMP TO EXISTING GROUND 7 SCALE: N.T.S HIGH CHAIN LINK ]VCE WITH REDWOOD SLATS 3? C.O.B. STD. DET. 0-12. EXISTING G_ROLNVD_ EXISTING GROUNG 2 C TEMPORARY SUMP SECTION 7 SCALE: N.T.S 2 EXISTING I I EXISTING GROUNG GROUNG 1� U-) �1 2 2 D TEMPORARY SUMP SECTION 7 SCALE: N.T.S .A REVISION APPROVED BY. ROGER A. McIN REVISION APPROVED BY: � a DANIEL PADILLA 1Z -/q ,/4 R.C.E. 33322 DATE R.C.E. 67008 DA1 EXISTING GROUNG ` M z V m J V) Z oZ j o J W o z z V) CL 0 N -> Li u� d^