HomeMy WebLinkAboutUST-DW REPORT 10/15/2014I
1�
co
co
m
<
VI
O
V
cz
co
E
m
z
(D
Lm
w
cn
cn
•
•
c"i 4
� R;
•
a
z
E
C/)
M
E
CL
C
C
C
O
zO
Cf)
E
O
F-
I
1�
co
co
m
<
VI
O
V
cz
co
E
m
z
(D
Lm
w
cn
cn
•
•
c"i 4
� R;
•
a
a
(X N
I�N
I
O
E
C
C
C
F-
F-
I--
E
cn
0
0
0
0
0
cn
cn
*a
ch
*.a
c h
-W
U )
cn
E
'E
E-
®
o
o
o
U.
E
E
>
-a
-a
-a
0
CL
o
m
c
c
c
LL
U.
CD
❑
❑
❑
❑
❑
❑
0
0 CZ
>
0
E
0
E
a
(X N
I�N
I
O
Underground Storage Tank Program
DW Inspection Repo�'-- Permission to Inspect: Aa'�
BAKERSFIELD FIRE DEPARTMENT
Prevention Services Division
2101 H Street
Bakersfield, CA 93301
Phone: 661 - 326 -3979
Fax: 661 -852 -2171
Business Name: Penske Truck Leasing Co., LP -15- 021 - 051661
Date:1211V-014
Address Name: 2929 East Brundage Lane- CAL000183641
Inspector Name: Shane Gardner #8248557
Inspection Type: Routine
Report: Final
NVO = No Violation Observed OUT = Out of Compliance NA = Not Applicable UD = Undetermined
COS = Corrected On Site RPT = Repeat Violation a6 d
Violation
Program Requirement
o SOC
Comments
No
D
�t
c
O
a
�o
z
O
z
v
o>
File Review
Facility Tank Information
2030021
Facility has a valid Permit
Tank 1- 12000 - DSL -DW
to Operate from the
Tank 2- 12000 - DSL -DW
CUPA - 23 CCR 16 2712(1);
�
❑
❑
❑
❑
❑
None
Tank 3-
HSC 6.7 25284
Tank 4-
2010010
UST Operating Permit
Application for Facility
information and Tank
information
F-1
E]
F-1
❑
❑
None
submitted /maintained - 23
CCR 16 2711; HSC 6.7
25286(a)
2010001
Current BOE number
submitted to the CUPA
❑
❑
❑
❑
❑
None
and /or CERS - HSC 6.7
25286(c)
2030011
UST compliance
statement and /or
Designated Operators
❑
❑
❑
❑
❑
None
current certification
submitted - 23 CCR 16
2715(a), 2715(b
2030046
A complete and accurate
response plan has been
submitted, approved and
❑
❑
❑
❑
❑
None
maintained - 23 CCR 16
2632, 2634(e), 2641(h),
2712(i)
2030041
A complete and accurate
plot plan has been
submitted, approved and
(
❑
❑
❑
❑
❑
None
maintained - 23 CCR 16
2632 d (1 )(C), 2711 a 8
2010006
Owner /Operator has not
made false statements or
representation on any
❑
❑
❑
❑
❑
None
required document -HSC
6.7 25299
2010003
Owner /Operator has a
DO and /or informed the
CUPA of any change (s)
❑
❑
❑
❑
❑
None
within 30 days - 23 CCR
16 2715(a)
Violation
Program Requirement
0
4)
SOC
Comments
No
0
0
CL
=
42 0)75 (a
Z
0
z
M
0
W
>
Testing
2030002
Owner/Operator has
tested and certified leak
1:1
❑
❑
None
detection equipment
annually - 23 CCR 16 2638
2030048
Secondary containment
testing conducted every
36 months in accordance
__j
None
with requirements - 23
CCR 16 2637
2030055
Spill buckets have been
tested annually as
❑
❑
1:1
❑
❑
None
required - HSC 6.7 25284.2
2010009
Secondary containment
test results submitted to
the CUPA within 30 days
1E1
❑
❑
1:1
❑
None
after the test - 23 CCR 16
2637(e)
2030064
CUPA was poperly
notified within the
prescribed number of
❑
❑
❑
1:1
❑
None
hours prior to testing - 23
CCR 16 2637(1), 2638(e),
2643(g), 2644.1(a)(4)
Install/Repair
2060009
Permits obtained to
install, replace, repair, or
❑
F-1
❑
❑
F-1
None
modify part of the LIST
system - 23 CCR 16 2712
UST System Observation
General Monitoring
2030003
Leak detection system
maintains continuous
RD
monitoring that activates
❑
❑
❑
❑
F-1
None
❑
an audible and visual
Yes
alarm - 23 CCR 16 2632,
2634, 2636, 2666
2030016
The annular space of the
tank, piping and sumps
RD
are continuously
monitored and activates
None
r-1
the alarm - 23 CCR 16
Yes
2631(g), 2632(c)(2)(A)&(8),
2633(c), 2636(o
2030017
Product piping outside the
UDC is fail-safe and shuts
down the pump or
❑
RE]
❑
❑
None
restricts flow - 23 CCR 16
636(0(5)
2030018
Turbine sump monitor
RD
activates an audible and
visual alarm or stops the
❑
❑
r-1
None
❑
flow of at the dispenser -
Yes
23 CCR 16 2636(0(1)
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
o
SOC
Comments
No
a
in
O
a
�o
z
o
z
D
v
o�
2030019
Monitoring system in the
UDCs activates an
audible and visual alarm
❑
❑
❑
❑
❑
None
or stops the flow at the
UDC -23 CCR 16
2636 (0(1)
2030043
Leak detection equipment
RD
properly programmed or
properly operated - 23
❑
❑
❑
❑
❑
None
❑
CCR 16 2632, 2634, 2636,
Yes
2666
2060005
System constructed with
a monitoring system
capable of detecting entry
❑
❑
❑
❑
❑
None
into secondary
containment - HSC 6.7
25291(b)
2060014
Correct leak detection
equipment installed for
RD
the type of system
❑
❑
❑
[]
❑
None
❑
present - 23 CCR 16 2638;
Yes
HSC 6.7 25290.1, 25290.2,
25291
2060015
Sensor located in the
RD
proper position /location -
None
❑
23 CCR 16 2630(d), 2641(a)
Yes
2030062
Facility is in compliance
RD
with not tampering with or
disabling leak detection
EY
❑
❑
❑
❑
❑
None
❑
devices or alarms - HSC
Yes
6.7 25299 a 9
2060022
System constructed with
a monitoring system
capable of detecting entry
❑
❑
❑
❑
❑
None
into secondary
containment - HSC 6.7
25290.2(d)
2030034
Tag /sticker on affixed
monitoring equipment
being certified, repaired,
❑
❑
❑
❑
❑
None
or replaced - 23 CCR 16
2638
VPH Monitoring VPH
2030065
Interstitial monitoring of
RD
the annular spaces of the
UST is properly
❑
❑
El
E-1
❑
None
❑
maintained - HSC 6.7
Yes
25290.1 e
2060023
System constructed with
a monitoring system
capable of detecting entry
into secondary
F-1
F1
❑
❑
F-1
None
containment - HSC 6.7
25290.1(d)
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
4-
0 0
SOC
Comments
No
0
o
0.
Z
0
Z
>
Line Leak
Detector
2060012
Line leak detector
installed on pressurized
RD
piping system - HSC 6.7
❑
❑
❑
❑
None
1:1
25290. 1 (h), 25290.2(g),
Yes
252910, 25292(e),
2636(0(2)
2030026
Line leak detectors detect
a 3 gph leak and/or
RD
audible and visual alarm
None
❑
function properly - 23
Yes
CCR 16 2636(0(6),
2666(c)
2030027
Turbine shuts down when
a leak is detected or
RD
when line leak detector is
None
❑
disconnected - 23 CCR 16
Yes
2666(c)
2030025
Pressurized piping able to
detect a 3.0 gph leak
RD
within an hour, and
❑
❑
❑
n
❑
None
❑
restricts the flow or
Yes
alarms - 23 CCR 16
2636(0 (2)
Secondary Containment
2060010
UST storing a hazardous
RD
substance has secondary
None
❑
containment - HSC 6.7
Yes
25292
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
4-
0 4).0
SOC
Comments
No
9
F-
<
Q
0
a-
4)
%m
00
Z
0
Z
2030008
UDC, sumps, and/or
other secondary
containment in good
None
condition and/or are free
of debris/liquid - HSC 6.7
25290.1, 25290.2, 25291
2030040
Secondarily contained
RD
piping maintained to allow
❑
❑
None
❑
liquid to drain into sump -
Yes
23 CCR 16 2630(d), 2641 (a)
2060006
Secondary containment
piping slopes back to the
❑
❑
❑
None
collection sump - 23 CCR
16 263(c)
2030047
Secondary containment
maintained tight and has
been confirmed by testing
None
- 23 CCR 16 2662, HSC 6.7
25290.1(c)(2), 25290.2(c)(2),
25291(a), 25292(e)
2030060
Entry fittings in secondary
containment for UST
system maintained
El/
None
tight/sealed - 23 CCR 16
2630, 2635(d), 2636(c),
2666
2060020
Spill bucket is installed
RP
and has a functional drain
valve or other means to
❑
❑
❑
None
❑
remove liquid - 23 CCR 16
Yes
2635(b), 2665
2030054
Spill bucket maintained in
RP
good condition and free of
❑
❑
❑
None
❑
debris and/or liquid - 23
Yes
CCR 16 2635(b), 2715(c)(2)
2060019
Spill bucket to has a
minimum capacity of five
None
gallons - 23 CCR 16
2635(b), 2665
Overfill
2030035
UST system is operated
RP
to prevent unauthorized
release, including spills
None
❑
and overfills - HSC 6.7
Yes
25292.1 (a)
2030036
Overfill prevention system
RP
has not been overridden
and meets overfill
None
❑
requirements - 23 CCR 16
Yes
2635(b)(2), 2665
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
W.
°0 o
SOC
Comments
No
0
>
M
0
0
(L
014)
0
z
0
z
M
v
of
On Site
Records
Certifications
2030023
Required designated
operators or contractors
01
maintain a proper and
E]
F
❑
F-1
None
None
current ICC certification -
23 CCR 16 2715
2030024
Service technician,
installer, and/ or
employee maintain a
❑
❑
❑
None
proper license - 23 CCR
162715
2030031
Employee or contractor
obtained and maintained
proper manufacturer
❑
❑
1:1
❑
❑
None
certification - 23 CCR 16
2715
2010007
Submit/maintain current
Certificate of Financial
Responsibility/mechanism
of financial assurance -
❑
❑
❑
❑
❑
None
23 CCR 16 2711; 23 CCR
18 2808.1, 2809-2809.2;
HSC 6.7 25292.2; HSC
6.75 25299.30-25299.34
Designated Operator
2010004
Copies of DO inspections
for last 12 months and list
of trained employees
❑
❑
❑
F-1
❑
None
maintained - 23 CCR 16
2715
2030013
Designated operator
properly conducted the
monthly inspection and
❑
❑
❑
❑
❑
None
the reports are complete -
23 CCR 16 2715
2030010
DO notified operator of
any condition observed
during the monthly
❑
El
El
El
Ej
None
inspection that may
Iff
require action - 23 CCR 16
2715(d)
2030012
DO employee training
performed, current for at
least one employee on
None
site, and a log kept - 23
CCR 16 2715(c)(6), 27150
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
%I-
0 0
0)
soc
Comments
No
a
0
(L
=
O)o 1102 M
Z
0
Z
M
Logs
2030001
Leak detection alarm
logs, maintenance and
RD
records of appropriate
❑
❑
None
❑
follow-up actions
Yes
maintained - 23 CCR 16
2632, 2634, 2712(b)
Maintenance/Tests
2010008
Monitoring, maintenance,
repairs, linings, and
RD
upgrade records
E
R
❑
❑
None
❑
maintained for the proper
Yes
time period - 23 CCR 16
1 2712(N
Documentation
2030033
Failure to maintain on site
an approved monitoring
None
plan - 23 CCR 16 2632,
2634, 2711, 2712(1)
2030037
Written agreement
between the tank owner
and tank operator to
monitor the tank system
❑
None
is maintained m 23 CCR 16
2620(b); HSC 6.7
25284(a)(3)
2030061
Suspected or actual
unauthorized release
RD
reported in appropriate
❑
❑
❑
❑
❑
None
❑
time frame - HSC 6.7
Yes
29294,29295
1
1
1
1
General Operating Requirements
Permit Condition/Approval
2030039
Compliance with all
operating permit
None
conditions - 23 CCR 16
2712, HSC 6.7 25299
2030059
UST system maintained
in accordance with
exclusion/exemption
❑
RE]
❑
E]
None
status - HSC 6.7 25281 . 6,
25283.5
2030014
Owner/Operator received
approval and has
implemented a training
❑
1:1
❑
E:]
❑
None
program at an unstaffed
facility m 23 CCR 16
2715 (2)
2030015
Facility exhibited that the
method used to monitor
the tank meets the
monitoring methods in
❑
❑
1:1
❑
❑
None
2643(f - 23 CCR 16 2643
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
° o
SOC
Comments
No
ac
o
(1)
o
a
Mo
z
o
z
o
oc
o>
Red Tag
2030045
Red Tag information is
legible and has not been
❑
❑
❑
❑
❑
❑
None
tampered with - 23 CCR
16 2717.1(
2030044
Facility did not allow for
deposit of petroleum into
a UST that has a red tag
❑
❑
❑
❑
❑
None
affixed to the fill - 23 CCR
16 2717.1
Install /Repair
2060024
UST system is made of or
lined with materials that
are compatible with the
❑
❑
❑
❑
❑
None
substance stored - 23
CCR 16 2631.1
2060021
Striker plate installed and
positioned correctly - 23
❑
❑
❑
❑
❑
None
CCR 16 2631(c), 2662(d)
There were no violations noted for this inspection.
❑This report shall serve as a "NOTICE TO COMPLY" for Minor Violations, and a "NOTICE OF VIOLATION" for
Major violations. You are, hereby, ordered to correct the above noted violations within 30 days, or according to
correction summaries provided. Formal enforcement and/or penalty assessment may be initiated for any
violations noted, and for those n t corrected in a timely manner. (NOTE: If this is a preliminary report, a final report
will follow.) 1/.? /
Inspectors Signature:
Date: --��
Inspector: Enter # of Violations: RD: RP:
Check, one box for facility Significant Operational Status (SOC) to be reported to SWRCB and US EPA:
l'
4) SOC with both Release Detection and Release Detection (Facility has no Release Prevention and no Release
Prevention Violations)
❑ Not in SOC (Facility has both Release Prevention and Release Detection Violations)
❑SOC with Release Detection only (Facility has no Release Detection violations but one or more Release Prevention
violations)
❑ SOC with Release Prevention only (Facility has no Release Prevention violations but one or more Release Detection
violations)
Underground Storage Tank Program - DW Inspection Report v 2.0