Loading...
HomeMy WebLinkAboutDW REPORTUnderground Storage Tank Program DW Inspection Report Permission to Inspect: BAKERSFIELD FIRE DEPARTMENT Prevention Services Division 2101 H Street Bakersfield, CA 93301 Phone: 661-326-3979 Fax, 661-852-2171 Business Name: KERN HIGH SCHOOL DIST TRANS DEPT-15-021-003244 Date: 11/12/2014 Address Name: 3701 E Belle Terrace Ave-CAL0001 29669 Inspector Name: Shane Gardner #8248557 Inspection Type: Routine Report: Final [N 0 COS = No Violation Observed OUT = Out of Compliance NA = Not Applicable UD = Undetermined OS = Corrected On Site RPT = Repeat Violation Violation Program Requirement o SOC Comments No a o 0. 0)73 z 0 z n 0 W File Review Facility Tank Information 2030021 Facility has a valid Permit Tank 1-12000-REG-DW to Operate from the Tank 2-12000-DSL-DW CUPA - 23 CCR 16 2712(i); None Tank 3-1000-Waste Oil-DW HSC 6.7 25284 Tank 4- 2010010 UST Operating Permit Application for Facility information and Tank information F-1 F-1 ❑ None submitted/maintained - 23 CCR 16 2711; HSC 6.7 25286(a) 2010001 Current BOE number submitted to the CUPA El 0 1:1 D F-1 None and/or CERS - HSC 6.7 Iff 25286(c) 2030011 UST compliance statement and/or Designated Operator None current certification submitted - 23 CCR 16 2715(a), 2715(b) 2030046 A complete and accurate response plan has been submitted, approved and ❑ ❑ ❑ ❑ ❑ None maintained - 23 CCR 16 2632, 2634(e), 2641(h), 2712(i) 2030041 A complete and accurate plot plan has been submitted, approved and ❑ 1:1 ❑ ❑ ❑ None maintained - 23 CCR 16 2632 (1)(C), 2711(a)(8) 2010006 Owner/Operator has not made false statements or representation on any None required document - HSC 6.725299 2010003 Owner/Operator has a DO and/or informed the CUPA of any change (s) ❑ ❑ ❑ None within 30 days - 23 CCR 16 2715(a) Violation Program Requirement %I- 0 0 0 SOC Comments No >0 a Q) 0 �_ a. = 2 (9 0)75 z 0 z Testing 2030002 Owner/Operator has tested and certified leak El El El ❑ None detection equipment annually - 23 CCR 16 2638 2030048 Secondary containment testing conducted every 36 months in accordance ❑ ❑ ❑ ❑ F-1 None with requirements - 23 CCR 16 2637 2030055 Spill buckets have been tested annually as ❑ ❑ ❑ None required - HSC 6.7 25284.2 2010009 Secondary containment test results submitted to the CUPA within 30 days ❑ ❑ ❑ ❑ ❑ None after the test - 23 CCR 16 2637(e) 2030064 CUPA was poperly notified within the prescribed number of ❑ ❑ ❑ ❑ ❑ None hours prior to testing - 23 CCR 16 2637(0, 2638(e), 2643(g), 2644.1(a)(4) Install/Repair 2060009 Permits obtained to install, replace, repair, or ❑ El 0 ❑ ❑ ❑ None modify part of the UST / system - 23 CCR 16 2712 'Observation UST System General Monitoring 2030003 Leak detection system maintains continuous RD monitoring that activates El E] None F1 an audible and visual Yes alarm - 23 CCR 16 2632, 2634, 2636, 2666 2030016 The annular space of the tank, piping and sumps RD are continuously monitored and activates ❑ ❑ ❑ None ❑ the alarm - 23 CCR 16 Yes 2631(8), 2632(c)(2)(A)&(B), 2633(c), 2636(o 2030017 Product piping outside the UDC is fail-safe and shuts down the pump or None restricts flow - 23 CCR 16 2636(0(5) 2030018 Turbine sump monitor activates an audible and RD visual alarm or stops the ❑ ❑ ❑ ❑ ❑ None ❑ flow of at the dispenser - Yes 23 CCR 16 2636(0(1) Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement o SOC Comments No M Q o o a ago z O z M y n! 05 2030019 Monitoring system in the UDCs activates an audible and visual alarm ❑ ❑ ❑ ❑ ❑ None or stops the flow at the UDC - 23 CCR 16 2636 (0(1) 2030043 Leak detection equipment properly programmed or RD properly operated - 23 ; ❑ ❑ ❑ ❑ ❑ None ❑ CCR 16 2632, 2634, 2636, Yes 2666 2060005 System constructed with a monitoring system capable of detecting entry ❑ ❑ ❑ ❑ ❑ None into secondary containment - HSC 6.7 25291(b 2060014 Correct leak detection equipment installed for RD the type of system ❑ ❑ ❑ ❑ ❑ None ❑ present - 23 CCR 16 2638, Yes HSC 6.7 25290.1, 25290.2, 25291 2060015 Sensor located in the RD proper position /location - ❑ ❑ ❑ ❑ ❑ None ❑ 23 CCR 16 2630(d), 2641(a) Yes 2030062 Facility is in compliance with not tampering with or RD disabling leak detection ❑ ❑ ❑ ❑ ❑ None devices or alarms - HSC Yes 6.7 25299 a (9) 2060022 System constructed with a monitoring system capable of detecting entry ❑ ❑ ❑ ❑ ❑ None into secondary containment - HSC 6.7 25290.2(d) 2030034 Tag /sticker on affixed monitoring equipment being certified, repaired, ❑ ❑ ❑ ❑ ❑ None or replaced - 23 CCR 16 2638 VPH Monitoring VPH 2030065 Interstitial monitoring of the annular spaces of the RD UST is properly ❑ ❑ ❑ ❑ ❑ None ❑ maintained - HSC 6.7 Yes 25290.1 e 2060023 System constructed with a monitoring system capable of detecting entry into secondary ❑ ❑ ❑ ❑ ❑ None containment - HSC 6.7 25290.1(d) Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement %I- 0 0 SOC Comments No 0 0 0 Z 0 Z M 0 4).- > Line Leak Detector 2060012 Line leak detector installed on pressurized RD piping system - HSC 6.7 M F] F1 n ❑ None ❑ 25290. 1 (h), 25290 ' 2(g), '�4 Yes 25291(0, 25292(e), 2636(0(2) 2030026 Line leak detectors detect a 3 gph leak and/or RD audible and visual alarm None ❑ function properly - 23 Yes CCR 16 2636(0(6), 2666(c) 2030027 Turbine shuts down when a leak is detected or RD when line leak detector is ❑ ❑ ❑ ❑ ❑ None ❑ disconnected - 23 CCR 16 Yes 2666(c) 2030025 Pressurized piping able to detect a 3.0 gph leak RD within an hour, and None ❑ restricts the flow or Yes alarms - 23 CCR 16 2636(0(2) Secondary Containment 2060010 UST storing a hazardous RD substance has secondary ❑ ❑ ❑ ❑ ❑ None ❑ containment - HSC 6.7 Yes 25292 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement 4- 0 0.0 SOC Comments No 0> Q a 0 M Q)0 Z 0 Z D 2030008 UDC, sumps, and/or other secondary containment in good ❑ None condition and/or are free of debris/liquid - HSC 6.7 25290.1, 25290.2, 25291 2030040 Secondarily contained RD piping maintained to allow ❑ On None ❑ liquid to drain into sump - Yes 23 CCR 16 2630(d), 2641 (a) 2060006 Secondary containment piping slopes back to the 1:1 E:] ❑ None collection sump - 23 CCR 16 263(c) 2030047 Secondary containment maintained tight and has been confirmed by testing ❑ ❑ ❑ ❑ ❑ None - 23 CCR 16 2662, HSC 6.7 25290.1(c)(2), 25290.2(c)(2), 25291 a , 25292(g) 2030060 Entry fittings in secondary containment for UST system maintained None tight/sealed - 23 CCR 16 2630, 2635(d), 2636(c), 2666 2060020 Spill bucket is installed and has a functional drain RP valve or other means to None ❑ remove liquid - 23 CCR 16 Yes 2635(b), 2665 2030054 Spill bucket maintained in RP good condition and free of None [:1 debris and/or liquid - 23 Yes CCR 16 2635(b), 2715(c)(2) 2060019 Spill bucket to has a minimum capacity of five X None gallons - 23 CCR 16 2635(b), 2665 Overfill 2030035 UST system is operated to prevent unauthorized RP release, including spills ❑ ❑ ❑ ❑ ❑ None ❑ and overfills - HSC 6.7 Yes 25292.1 (a) 2030036 Overfill prevention system has not been overridden RP and meets overfill None ❑ requirements - 23 CCR 16 Yes 2635(b)(2), 2665 1 1 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement 4- °0 o SOC Comments No 0 0 0. w co O)o z 0 z M y W On Site Records Certifications 2030023 Required designated operators or contractors maintain a proper and ❑ 1:1 F-1 ❑ ❑ None current ICC certification - 23 CCR 16 2715 2030024 Service technician, installer, and/ or 6*1s- I ca q employee maintain a X ❑ ❑ None VK--fos-4-6� C--'Fr proper license - 23 CCR 16271 2030031 Employee or contractor obtained and maintained proper manufacturer 11 ❑ ❑ ❑ r--j ❑ None certification - 23 CCR 16 2715 2010007 Submit/maintain current Certificate of Financial Responsibility/mechanism of financial assurance - ❑ 1-1 ❑ El ❑ None 23 CCR 16 2711; 23 CCR 18 2808.1, 2809-2809.2, HSC 6.7 25292.2; HSC 6.75 25299.30-25299-34 Designated Operator 2010004 Copies of DO inspections for last 12 months and list of trained employees Ex ❑ ❑ 1:1 1:1 ❑ None maintained - 23 CCR 16 2715 2030013 Designated operator properly conducted the monthly inspection and ❑ ME] None the reports are complete - 23 CCR 16 2715 2030010 DO notified operator of any condition observed during the monthly ❑ ❑ ❑ ❑ ❑ None inspection that may require action - 23 CCR 16 2715(d) 2030012 DO employee training performed, current for at least one employee on ❑ ❑ ❑ None site, and a log kept - 23 CCR 16 2715(c)(6), 2715(o Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement 4_ 0 .2 w SOC Comments No 9 < in 0 CL I'M Z 0 Z M 0 > Logs 2030001 Leak detection alarm logs, maintenance and RD records of appropriate El El D None F� follow-up actions Yes maintained - 23 CCR 16 2632, 2634, 2712(b) Maintenance/Tests 2010008 Monitoring, maintenance, repairs, linings, and RD upgrade records ❑ ❑ ❑ ❑ ❑ None ❑ maintained for the proper Yes time period - 23 CCR 16 2712(b) Documentation 2030033 Failure to maintain on site an approved monitoring None plan - 23 CCR 16 2632, 2634, 2711, 2712(1) 2030037 Written agreement between the tank owner and tank operator to monitor the tank system ❑ ❑ ❑ ❑ ❑ None is maintained - 23 CCR 16 2620(b); HSC 6.7 25284(a)(3) 2030061 Suspected or actual unauthorized release /1:1 RD reported in appropriate b ❑ 1:1 1:1 ❑ ❑ None ❑ time frame m HSC 6.7 Yes 29294,29295 1 1 1 1 General Operating Requirements Permit Condition/Approval 2030039 Compliance with all operating permit El ❑ None conditions - 23 CCR 16 2712, HSC 6.7 25299 2030059 UST system maintained in accordance with exclusion/exemption )7f ❑ ❑ ❑ None status - HSC 6.7 25281.6, 25283.5 2030014 Owner/Operator received approval and has implemented a training ❑ ❑ None program at an unstaffed facility - 23 CCR 16 2715 (0(2) 2030015 Facility exhibited that the method used to monitor the tank meets the monitoring methods in None 2643(f) - 23 CCR 16 2643 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement 4- 0 0 4) = SOC Comments No 93 0 W W I z 0 z Red Tag 2030045 Red Tag information is 'E] legible and has not been ❑ ❑ ❑ ❑ None tampered with - 23 CCR 16 2717.1 (g) 2030044 Facility did not allow for deposit of petroleum into a LIST that has a red tag r­1 ❑ ❑ None affixed to the fi ll - 23 CCR 162717.1(0 -- Install/Repair 2060024 UST system is made of or lined with materials that are compatible with the F-1 ❑ ❑ ❑ ❑ None substance stored - 23 CCR 16 2631.1 2060021 Striker plate installed and positioned correctly - 23 None CCR 16 2631(c), 2662(d) JZ'There were no violations noted for this inspection. ❑This report shall serve as a "NOTICE TO COMPLY" for Minor Violations, and a "NOTICE OF VIOLATION" for Major violations. You are, hereby, ordered to correct the above noted violations within 30 days, or according to correction summaries provided. Formal enforcement and/or penalty assessment may be initiated for any violations noted, and for those not corrected in a timely manner. (NOTE: If this is a preliminary report, a final report will follow.) Inspectors Signature: Date: Inspector: Enter # of Violations: RD: e::z--> RP: <- Check one box for facility Significant Operational Status (SOC) to be reported to SWRCB and US EPA: SO C with both Release Detection and Release Detection (Facility has no Release Prevention and no Release Prevention Violations) ❑ Not in SOC (Facility has both Release Prevention and Release Detection Violations) ❑SOC with Release Detection only (Facility has no Release Detection violations but one or more Release Prevention violations) ❑ SOC with Release Prevention only (Facility has no Release Prevention violations but one or more Release Detection violations) Underground Storage Tank Program - DW Inspection Report v 2.0