HomeMy WebLinkAboutHAZMAT INSP 4/2017BAKERSFIELD FIRE DEPARTMENT FIRE PREVENTION INSPECTION B 1E, R S F it D Prevention Services F�Re 2101 H Street n aRTM Bakersfield, CA 93301 Phone: 661 - 326 -3979 •Fax: 661 - 852 -2171 DISTRICT BLOCK NO. DATE FEE FACILITY ADDRESS CIT�I, 4 E, 1 I ( i 2� FACILITY NAME MANAGER'S NAME PH NO. BUSINESS OWNER'S NAME AND ADDRESS CITY, STATE, ZIP PH NO. BILL TO: (IF DIFFERENT FROM ABOVE) NAME, ADDRESS A CITY, STATE, ZIP PH NO. OCC TYPE OCC LOAD O. F FLOORS HIGH RISE BLDG RISER DATE ❑YES f°N� -T_ { - IREQU EMEN PF CORRECT ALL VIOLATIONS VIOLATION NO' CHECKED BELOW x 1 Remove and safely dispose of all hazardous refuse a d \vketatidkon the above premises COMBUSTIBLE WASTE I DRY (CFC 304.1 .1) VEGETATION 2 Provide non- corribustible containers with tight fitting lids or he storage of combustible waste and rubbish pending its safe disposal. `, (CFC 304.3.2) Note: applies to containers over 40 gallons. gip. 3 y Relocate combustible storage to provide at least 3 feet clearance around motor fuse box /fire door COMBUSTIBLE STORAGE ell (CFC 605.3) 4 Relocate fire extinguisher(s) so Tat they will be in a conspicuous location, hanging on brackets with the top to the extinguisher not morethan 5 feet above the floor. (CFC 906.5 & 906!.9) 5 Provide and install (amount) approved (type & size) portable fire- EXTINGUISHERS extinguisher to be immediateft accessible for use in (area) (CFC TABLE 906.3(1)) 6 Re- charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and /or after each use, by a pers , n having a valid license or certificate. (CFC 906.2) 7 Provide and maintain " IT" sign(s) with letters 6 or more inches in height over each required exit" SIGNS (door /window) to fire eape. (CFC 1011) 8 Provide and maintain appropriate numbers on a contrasting background and visible from the street to '�: { indicate the correct address of the building. (CFC 505.1) r 9 Repair all (cracks /holes /openings) in plaster in (location) ` FIRE DOORS / Plastering shall return the surface to its original fire resistive condition. (CFC 703.1) FIRE SEPARATIONS 10 Remove /repair (it fm & location) Self - closing doors shall be designed to close by gravity, or by the action Of mechanical device, or by an approved smoke ind heat sensitive device. Self - closing doors shall have no attachments capable of preventing the operation of the closing device. (CFC 703.2) 11 Remove all obstru 'ion from hallways. Maintain all means of egress free of any storage. (CFC 1028.3) EXITS 12 Provide a contrasting colored and permanently installed electric light over or,.a.ea.r- required -exit (location) '° to early" "M icate it as an exit. (CFC 1006.3) STORAGE 13 Remove all storage and /or otf"ie`rabst�- i ns from fire escape landings and stairways stair shafts. (Fire escapes /stair shafts are to be maintained free from obstructions at all times.) (CFC 1003.6) 14 Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved ELECTRICAL APPLIANCES electrical outlets where needed. (CFC 605.5) 15 Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) (CFC 605.4) OUTDOOR BURNING 16 Recreational fires or open burning. (CFC 307..1) FIREWORKS 17 Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.). OTHER 18 -. Y„ CORRECTION DATE Correct the violations noted above by: LEGEND: C.F.C. CALIFORNIA FIRE CODE CUSTOMER: C.B.C. CALIFORNIA BUILDING CODE (n ture) (Please Print Name Legibly, Itle) 7 B.M.C. BAKERSFIELD MUNICIPAL CODE N.F.P.A. NATIONAL FIRE PROTECTION ASSOCIATION NO.. INSPECTOR: N.E.C. NATIONAL ELECTRIC CODE FD 2022 (Rev. 06/14) White - Customer /Oriainal Yellow - Station Coov Pink - Prevention Services I