Loading...
HomeMy WebLinkAbout1.6-7246 Ph 1 & 2APPROVED BY: WATER DIRECTOR DATE CITY OF BAKERSFIELD, DOMESTIC WATER DIVISION CALIFORNIA WATER SERVICE COMPANY, AS AGENT FOR INSPECTION TO THE CITY, SHALL BE NOTIFIED AT LEAST 24 HOURS PRIOR TO THE START OF CONSTRUCTION. CITY ACKNOWLEDGEMENT OF WATER PLANS FOR CONSTRUCTION AND APPROVAL OF PLANS BY SIGNATURE DOES NOT ABROGATE CITY WRITTEN SPECIFICATIONS BY OMISSION OR MISINTERPRETATION. AUTHORIZED CITY INSPECTORS OR AGENTS MAY REQUIRE CHANGES IN PLANS BEFORE CERTIFICATION AND ACCEPTANCE IN ORDER TO COMPLY WITH STANDARD SPECIFICATIONS. BENCHMARK USED: TOP OF CONCRETE MONUMENT IN A LAMPHOLE AT THE SOUTHEAST CORNER OF SECTION 13-30/26, BEING ABOUT 50—FEET SOUTH OF THE RAILROAD TRACK ALONG THE CENTERLINE OF BUENA VISTA ROAD. ELEVATION = 354.13 BASIS OF BEARINGS: THE BEARING OF N 00'57'45" E ALONG THE CENTERLINE OF BUENA VISTA ROAD AS SHOWN ON PARCEL MAP 11838 PHASE 2 RECORDED IN BOOK 57 OF PARCEL MAPS AT PAGE 169 IN THE OFFICE OF THE KERN COUNTY RECORDER WAS TAKEN AS THE BASIS OF BEARINGS SHOWN HEREON. LEGAL DESCRIPTION- A PORTION OF SECTION 13, TOWNSHIP 30 SOUTH, RANGE 26 EAST MOUNT DIABLO BASE AND MERIDIAN, IN THE CITY OF BAKERSFIELD, COUNTY OF KERN, STATE OF CALIFORNIA. VICINITY MAP NO SCALE "Y,E;TEM TR,ACAT 7,,,.46 P1 A%:)EIS 1-2 AK RSF:1 LD, CALIFORNIA CITY STANDARD v s L co!( )uc cy 1[:TR-6223 � 1-7' s1 OV, h �� i ��S( FOLLOWING i00L WHITE LANE. A PART OF THESE PLANS. CONTRACTOR TO C`BTAIN LATEST EDITION. LOT 1 PM No. CITY 11961 1 i PROJECT DoT i 1LLA 0351 p LLA No. 13-0176 Q SITE LOT f ` 1 LOT 1 LLA No. 12-0133 W0. 13-0176 o. 4861 Iw _u W-3 LOT 3 Ja LLA No. 13-0176 a �- LOT 2 `-- _'J LAK :. 1 P LLA No. 12-01 33 r /` _ -- ` Q TO BE VACATED r i+ R` 5 m F _ a w N TR 6116 AND REAUGNED W-5 ! �z LOT 2 ��------ LLA ® r rj Na 13-0179REMAINDER -- -- OF PARCEL A o� Z o z TR -5135 W OF P.M.W. 08-1182 -e „� m L VTPM 11838 t t UI LOT 4 LLA No. TR -5196 "1" t 1 �t 12-0133 i VTPM 11838 ❑ tt �1 4" & LARGER TURNOUT WEST MING SPECIFIC PLAN AREA TYPICAL METER BOX LOCATION ® VICINITY MAP NO SCALE "Y,E;TEM TR,ACAT 7,,,.46 P1 A%:)EIS 1-2 AK RSF:1 LD, CALIFORNIA CITY STANDARD PLATES (TYPICAL ALL SHEETS) 1- THE FOLLOWING CITY OF BAKERSFIELD DOMESTIC WATER STANDARD DRAWINGS SHALL BE CONSIDERED A PART OF THESE PLANS. CONTRACTOR TO C`BTAIN LATEST EDITION. CITY STD. NO. DESCRIPTION ® W-1 STANDARD PIPE TRENCH ® W-2 THRUST BLOCK DETAIL ® W-3 FIRE HYDRANT ASSEMBLY ® W-4 BLOWOFF ASSEMBLY - PAVED AREA ❑ W-5 COMBINATION AIR VALVE ® W-6 END OF LINE BLOWOFF ASSEMBLY - UNPAVED AREA ❑ W-7 PIPE BORE AND CASING DETAIL ® W-8 STANDARD SERVICE CONNECTION - 3/4" TO 2" ❑ W-9 3", 4", & 6" WATER SERVICE DETAIL ❑ W-10 4" & LARGER TURNOUT ® W-11 TYPICAL METER BOX LOCATION ® W-12 VALVE BOX DETAIL ❑ W-13 CANAL CROSSING DETAIL ❑ W-14 CONCRETE SADDLE DETAIL ❑ W-15 SAFETY FENCE DETAIL ❑ W-16 IRRIGATION, FIRE & WATER SERVICE REQUIRING BOOSTER PUMP ❑ W-17 ALTERNATE AIR -GAP INSTALLATION REQUIREMENTS ❑ W-18 TYPICAL FIRE SERVICE DETAIL : CONTRACTOR SHALL OBTAIN LATEST COPY OF STAND 4RD DRAWINGS AND SPECIFICATIONS FROM CITY OF BAKERSFIELD WATER RESOURCES DEPARTMENT NOTE: CONTRACTOR SHALL OBTAIN LATEST COPY OF CITY OF BAKERSFIELD WATER RESOURCES DEPARTMENT SPECIFICfJIONS PRIOR TO BIDDING AND SHALL BE ON DEPARTMENT'S APPROVED CONTRACTOR LIST FOR TIE—IN TO EXISTING MAIN. SHEET No.INDEX M TITLE SHEET ® STANDARD NOTES & DETAILS C3 WATER SYSTEM (FLAN VIEW --NORTH HALF) O WATER SYSTEM (P -AN VIEW—SOUTH HALF) U LL wa.WO m0� Z0a.zzy wpwP LL0aa0 W WLU.-lil�_w w Oq. TKO wz0!gmwp U. 04= < ww=�- almz mT8w1ffiww*V- wo C93 6 LL 9% w!5 Z z u 0 w� ¢aazOw ZwZ azak<� F - X — �a'O -%z 8io� 3w 0z10 ul 0p00z0 u�z� ���Owiw ww� wjOUz=cO9 po§jgc aazz> pwZwpw4E00 �w1--a. wF_w0Q,0aa. z�oww 0w0Qaa' �aoZpa w>G�na �toll -ZmaaiQZNygsULLz�,—vC) w1 yCVUZgs 0 00 0 0 0 ow w y_ Sao 8 o0 - pw0OW �w�-Ozm �a0WwMOMMc-'.j3�>m wwv�wz v»-cn 10 _ z )� �� th • In L0 U,1 ` ) LLIz r Lu CIu.4� cf.I -� Q o: to c", ul w 'ai cfI 06 0Ny_Z ;2) c, 1..(.. 0 Cr? of LLI Z W cc) C) i eV a. E i C \ a t)• !. ui 1jL u, t�. I W =' 1- ) �\ q_ z �' m Z ui w > iLl u; IX tl a; c La =Q;zz;; A 00 w U �aw v ` � a �y , S�4s PROPOSED WATER LINE -`----- PROPOSED WATER LINE PER PARCEL MAP 12100 Sy WATER SYSTEM PLANS NS s _ — PROPOSED FIRE -HYDRANT PROPOSED FIRE—HYDRANT PER PARCEL MAP 12100 WHITE LANE v WATER SYSTEM PLANS — — — — — -- -- — -- — — -- — ' 9 10 11 12 13 14 15 16 17 18 I < MATERIALS LIST I I'I �i _ I _j _i_ _�!__ -- -- - - --- ...J t,� I (L _ c) BLUEGRASS _ _ LADIE _ ► Q r ESTIMATED QUANTITIES I. -OR PLAN � r _ — — � 7 � 3I � `'� �... CHECK AND INSPECTION FEE CALCULATIONS. NOT TO BE USED FOR BIDDING PURPOSES. 27 26 25 24 23 22 21 20 19� / Cr ! ' q L. J 6 WATER LIJ PHASE 1 _ \( t ` t I 5 29 30 31 32 33 34 35 rw 8" P.V.C. WA -`ER MAIN 1880 LF 1 Itjl \ t I i // ma 28 8" GATE VALVES 5 EA 8" 45' ELBOW' 2 EA4 , l 2 — — s� 1 ,� 8" TEE 2 EA t SII `��` `---"-�� LAUREN _ COURT L� -- _ — , BLOW OFF ASSEMBLY (PAVED F,REA) 4 EA i I f r ♦A NI FIRE -HYDRANT ASSEMBLY 3 Eq III -' —� - �' 3 36 qy V J r� (MI " TEN TATI VI 42 41 40 39 3$ 37 �r i� 1 . – 1 STANDARD SERVICE CONNEC f10N 38 EA ' 1 �tl TRACT 72:i 4� ,c- 43 , PHASE 2 9 1 t'1— -- — — - -' "{, ' 2 '°n` PHASE 2 8" P.V.C. WA "ER MAIN 2073 LF, j PHASE 1 r 8" GATE V 1 �` 1 W 8" 45* ELBOA' 3 EA ,ti �t ` ,�t� �C �; ' 38 37 36 35 34 333 8 TEE 1 EA 1 r \ FIRE -HYDRANT ASSEMBLY 3 Eq TIE-IN(S) 3 EA �� �� �` \i 2s=�N�R'�' 1 STANDARD SERVICE CONNEC TION 43 EA ( i 25 / / S i 24 32 2 31 / o 1 r � 3 2 0 27 22 28 \ `/� / �0) 29 ,�.._.r..w„�.. � o 14 16f.- �Q� / / / , 3 6 �/ / �` 7 12 18 w S l� 10 UNDERGROUN) SERVICE ALERT \ \ g , TEN TATI VE OFSOUTHEINCAUFORNIA \\ `� �, r , \ /TRACT 7247 -a ti p /TENTATIVE _ z eFORE yaoU TRACT 7248iFUTURE / v c \ COMMUNITY FUTURE\ CENTER U s PARK SITE GATE 9/t r5/2tt 14 FA JOB Nc,. 1 %3.2750H cl sFc/FUN D SE01 CL DIV. TOLL FR EE lMD-227.2600 _ N_ z AT LEAST TWO GAYS BEFORE YOU DIG KEY M A i SCALE: 1'=200' OF 4 S SEE`'$ CONTRACTOR SHALL FURNISH ALL MATERIALS, TOOLS, LABOR, EQUIPMENT, SUPERVISION AND TESTING NECESSARY FOR A COMPLETE INSTALLATION OF THE WATER SYSTEM. THE FOLLOWING NOTES ARE FROM THE CITY OF BAKERSFIELD STANDARDS AND SPECIFICATIONS FOR DOMESTIC WATER SYSTEMS AND ARE FOR REFERENCE ONLY, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN THE LATEST EDITION THEREOF. 5.2 QUALITY OF MATERIALS: ALL MATERIAL INCORPORATED INTO THE WORK SHALL BE NEW AND SHALL CONFORM TO THESE STANDARDS AND SPECIFICATIONS. NO MATERIAL SHALL BE INCORPORATED INTO THE WORK UNTIL IT HAS BEEN APPROVED BY THE INSPECTOR. ANY REJECTED MATERIAL SHALL BE IMMEDIATELY REMOVED FROM THE SITE. 5.2.1 CERTIFICATE OF COMPLIANCE: A CERTIFICATE OF COMPLIANCE SHALL BE FURNISHED PRIOR TO THE USE OF ANY MATERIALS OR EQUIPMENT. THE CERTIFICATE SHALL BE SIGNED BY THE MANUFACTURER OF THE MATERIALS OR EQUIPMENT. A CERTIFICATE OF COMPLIANCE SHALL BE FURNISHED WITH EACH LOT OF MATERIAL DELIVERED TO THE WORK AND THE LOT SO CERTIFIED SHALL BE CLEARLY IDENTIFIED IN THE CERTIFICATE. 5.3 POLYVINYL CHLORIDE PIPE (PVC): PVC PIPE SHALL BE MANUFACTURED FOR USE IN WATER SYSTEMS AND SHALL BE DESIGNATED AS CLASS 150 (DR18) OR CLASS 200 (DR14), AND SHALL COMPLY WITH AWWA C900 SPECIFICATIONS FOR 12" AND LESS, AND AWWA C905 FOR PIPE 14" TO 36" IN DIAMETER. OUTSIDE DIAMETER OF PVC PIPE SHALL BE EQUIVALENT TO CAST-IRON PIPE. 5.3.1 PVC JOINTS: PVC PIPE SHALL HAVE ELASTOMERIC GASKET JOINTS, EITHER GASKET BELL AND SPIGOT TYPE OR PLAIN END WITH GASKET COUPLING TYPE. 5.3.2 FITTINGS: SPECIALS AND FITTINGS SHALL BE DUCTILE -IRON CONFORMING TO AWWA SPECIFICATION C100, CLASS D, EXCEPT THAT FITTING SHALL HAVE ALL BELL CONNECTIONS OF STANDARD AWWA DIMENSIONS OR SPECIAL DIMENSIONS AS REQUIRED, OR FITTINGS SHALL BE EQUIPPED NTH ADAPTERS OF THE PROPER CLASS FOR THE SIZE OF PIPE, AS RECOMMENDED BY THE PIPE MANUFACTURER, OR EQUAL. PROTECTIVE COATING SHALL BE IN ACCORDANCE WITH SECTION 5.15 OF THESE SPECIFICATIONS. 5.5 STEEL PIPE: STEEL PIPE SHALL BE BLACK STEEL CONFORMING TO AWWA SPECIFICATION C-202, AND SHALL HAVE A MINIMUM WALL THICKNESS EQUAL TO THE REQUIREMENTS OF GENERAL ORDER NO. 103 OF THE PUBLIC UTILITIES COMMISSION, STATE OF CALIFORNIA. 5.5.1 TEMPORARY PIPE: TEMPORARY TRANSMISSION STEEL PIPE SHALL BE DOUBLE DIPPED WITH ASPHALT AND WRAPPED WITH ASBESTOS FELT OR FIBERGLASS IN CONFORMANCE WITH APPENDIX B OF SAID GENERAL ORDER NO. 103. 5.5.2 PERMANENT PIPE: PERMANENT TRANSMISSION STEEL PIPE SHALL BE LINED AND COATED IN ACCORDANCE WITH SECTION 5.15 OF THESE SPECIFICATIONS. 5.5.3 SMALL SIZE PIPE FOR BLOW -OFFS OR SIMILAR USES SHALL BE BRASS. 5.5.4 STEEL PIPE JOINTS: FITTINGS AND SPECIAL FABRICATION, "SPECIALS", FOR PIPES 4 INCHES AND LARGER IN DIAMETER SHALL BE OF THE SAME MATERIAL AND THICKNESS AS THE PIPE. "SPECIALS" AND FITTINGS SHALL BE MADE OF STANDARD STEEL TUBE TURNS WITH ENDS TO ACCOMMODATE THE TYPE OF COUPLING SPECIFIED FOR THE PIPE. FITTINGS SHALL BE LINED, COATED AND WRAPPED AS SPECIFIED FOR THE PIPE. "SPECIALS" AND FITTINGS THAT CANNOT BE MECHANICALLY LINED, COATED AND WRAPPED, SHALL BE LINED, COATED AND WRAPPED BY HAND, USING THE SAME MATERIALS AS SPECIFIED FOR THE PIPE, WITH THE SAME NUMBER OF APPLICATIONS OR EACH MATERIAL, CAREFULLY AND SMOOTHLY APPLIED. CAST-IRON FITTINGS CONFORMING TO THESE SPECIFICATIONS MAY BE USED WITH TRANSITION FITTINGS OR ADAPTERS. 5.5.5 WELDED FITTINGS: STEEL WELDED FITTINGS SHALL CONFORM TO THE REQUIREMENTS OF ASTM DESIGNATION A-234. 5.5.6 FLANGES: STEEL PIPE FLANGES SHALL CONFORM TO THE REQUIREMENTS OF AWWA SPECIFICATION C-207. 5.5.7 BOLTS: MATERIAL FOR BOLTS SHALL CONFORM TO THE REQUIREMENTS FOR OPEN HEARTH, FREE CUTTING GRADE BAR STEEL, ASTM DESIGNATION A-107. BOLTS SHALL HAVE A MINIMUM TENSILE STRENGTH OF 60,000 PSI. BOLT HEADS SHALL BE EITHER SQUARE OR HEXAGON AND NUTS SHALL BE COLD PRESSURED SEMI -FINISHED HEXAGON. 5.5.8 GASKETS: FLANGED JOINTS SHALL BE PROVIDED WITH 1/16TH-INCH THICK GASKETS, CRANITE, OR EQUAL. 5.5.9 VICTAULIC COUPLINGS: WHEN VICTAULIC COUPLINGS ARE INDICATED ON THE DRAWINGS, STYLE 77 DRESSER VICTAULIC COUPLINGS, OR AN APPROVED EQUAL, SHALL BE FURNISHED. THE VICTAULIC COUPLING SHALL BE DESIGNED FOR 150 PSI, WORKING PRESSURE. 5.5.10 SLEEVE -TYPE COUPLINGS: SLEEVE -TYPE COUPLINGS SHALL BE STYLE 38 DRESSER OR SMITH-BLAIR ADAPTER COUPLINGS OR APPROVED EQUAL, AND SHALL BE OF STEEL WITH STEEL BOLTS, WITHOUT CENTERING RING. THE MIDDLE RING SHALL BE NOT LESS THAN 1/4 INCH IN THICKNESS. 5.6 VALVES: ALL VALVES SHALL BE CAST-IRON BODY, BRONZE MOUNTED, SOLID BRONZE INTERNAL WORKING PARTS WITH NON -RISING STEMS, AND SHALL BE OPENED BY TURNING COUNTER -CLOCKWISE. BRONZE SHALL BE GRADE 1 AND SHALL CONFORM TO ASTM -B-62 (85-5-5-5) BRONZE (85% COPPER, 5% ZINC, 5% LEAD, AND 5% TIN). VALVES SHALL BE DESIGNED FOR A MINIMUM WORKING PRESSURE OF 150 PSI. VALVES 2 INCHES AND LARGER SHALL CONFORM TO THE REQUIREMENTS OF AWWA C500, EXCEPT AS OTHERWISE PROVIDED IN THESE SPECIFICATIONS. VALVES SMALLER THAN 2 INCHES SHALL CONFORM TO THE REQUIREMENTS OF FEDERAL SPECIFICATION WW -V-54. 5.6.1 TESTS: EACH VALVE SHALL HAVE THE MANUFACTURER'S INITIALS, PRESSURE RATING, AND YEAR OF MANUFACTURE CAST IN THE BODY. VALVES SHALL BE TESTED AT THE FACTORY AT A HYDRAULIC PRESSURE EQUAL TO TWICE THE SPECIFIED WATER WORKING PRESSURE. FACTORY TEST RESULTS SHALL BE SUPPLIED TO THE DEPARTMENT UPON REQUEST. 5.6.2 COATING: ALL VALVE BODIES AND CAST-IRON PORTIONS OF THE HOUSINGS AND EXTENSIONS SHALL BE COATED IN ACCORDANCE WITH SECTION 5.15 OF THESE SPECIFICATIONS. 5.6.3 GATE VALVES: GATE VALVES SHALL BE DOUBLE -DISC, PARALLEL FACED AND SHALL HAVE A CLEAR WATERWAY EQUAL TO THE FULL NOMINAL DIAMETER OF THE PIPE. RESILIENT SEALED GATE VALVES IN ACCORDANCE WITH AWWA C509, ARE APPROVED FOR USE BY THE DEPARTMENT. 5.6.4 BUTTERFLY VALVES: BUTTERFLY VALVES SHALL BE RUBBER -SEATED AND SHALL COMPLY WITH AWWA C-504, CLASS 150-B GEAR OPERATED UNLESS OTHERWISE APPROVED BY THE DEPARTMENT. THE DISC SHALL BE CAST IRON ASTM A-126 CLASS B OR ASTM A-48 CLASS 40 IN SIZES 24" AND SMALLER OR DUCTILE IRON IN CONFORMANCE WITH ASTM A-536 FOR 30" AND LARGER, AND SHALL ROTATE 90 DEGREES BETWEEN THE FULLY OPEN AND FULLY CLOSED POSITIONS. BUNA-N RUBBER SEATS SHALL BE SECURELY HELD IN-PLACE BY NICKEL CAST-IRON OR TYPE 316 STAINLESS STEEL RETAINING SEGMENTS, OR SHALL BE BONDED TO THE BODY AND MEET TEST PROCEDURES OUTLINED IN ASTM D-429 METHOD B. 5.6.5 AIR AND VACUUM RELEASE VALVES: AIR AND VACUUM RELIEF VALVES SHALL BE EQUAL TO NO. 31 AUTOMATIC DIAPHRAGM VALVE AS MANUFACTURED BY CLA-VAL CO., NEWPORT BEACH, CALIFORNIA. 5.7 VALVE BOXES: VALVE BOXES IN SIDEWALKS, PARKWAYS, AND OTHER AREAS SHALL CONSIST OF A CAST IRON VALVE BOX AND RISER AND A CAST IRON LOCKING COVER IN ACCORDANCE WITH THE STANDARD DETAILS. THE CAST-IRON COVERS SHALL BE HOT -DIPPED ASPHALT -COATED AND SHALL HAVE THE WORD "WATER" CAST IN THE TOP. IN ANY AREAS SUBJECT TO TRAFFIC, A CLASS "B" CONCRETE PAD SHALL BE POURED AROUND THE RISER IN ACCORDANCE WITH THE STANDARD DETAILS. 5.8.4 WATER SERVICE PIPE FOR SERVICES LARGER THAN 2 INCHES SHALL COMPLY WITH THE REQUIREMENT OF P.V.C. AS SPECIFIED HEREIN. 5.9 CORPORATION STOPS: ALL CORPORATION STOPS SHALL BE BRONZE OR BRASS, ROUND, WITH INLET FOR EITHER CORPORATION STOP (C.S.) THREAD FOR PVC OR DUCTILE -IRON PIPE, OR IRON PIPE STANDARD (I.P.S.) THREAD FOR STEEL PIPE, AN) OUTLET FOR THE TYPE OF SERVICE PIPE USED. 5.10 METER STOPS: ALL METER STOPS SHALL BE BRONZE OR BRASS, WITH INLET FOR THE TYPE OF SERVICE PIPE USED, AND OUTLET FOR THE TYPE OF SERVICE PIPE OTR METER COUPLING USED. 5.11 FIRE HYDRANTS: FIRE HYDRANTS SHALL BE PURCHASED DIRECTLY FROM THE CITY OF BAKERSFIELD FIRE DEPARTMENT. FIRE HYDRANTS SHALL BE MUELLER COMPANY NO. A-24009 COMPLETE WITH PROPER BURY LENGTH, EXCEPT FIRE HYDRANTS SHALL BE JONES COMPANY J-344 WHERE ANGLE FIRE PLUGS HAVE BEEN INDICATED. HOSE THREADS SHALL BE NATIONAL STANDARD HOSE THREADS. 5.12 PORTLAND CEMENT CONCRETE: PORTLAND CEMENT CONCRETE SHALL BE CLAS'3 "B" AND SHALL CONTAIN A MINIMUM OF 5 SACKS (470 POUNDS) OF CEMENT PER CUBIC YARD. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI AT 28 DAYS. 5.12.1 MATERIALS FOR CONCRETE SHALL BE PORTLAND CEMENT CONFORMING TO ASTM SPECIFICATIONS FOR TYPE I OR TYPE 11, WELL GRADED, SOUND, NON-REACTIVE AGGREGATE, AND CLEAN WATER. 5.15 PROTECTIVE COATINGS: ALL VALVES, FLANGES, BOLTS, FITTINGS AND PIPING FOR INSTALLATION SHALL BE SHOP COATED AND FIELD REPAIRED AS NECESSARY PRIOR TO BACKFILLING IN CONFORMANCE WITH THE FOLLOWING SCHEDULE: 1. EXTERIOR SURFACES OF BURIED COAL TAR EPDXY OR AWWA C 205 STEEL PIPE TO A POINT 4 CEMENT MORTAR INCHES ABOVE FINISH GRADE. 2. INTERIOR SURFACES OF STEEL COAL TAR EPDXY OR AWWA C 205 PIPE. FUSION EPDXY 3. ALL EXPOSED FERROUS METAL RED PRIMER 2 COATS SURFACES. 3 MILS 4. BURIED VALVES, COUPLINGS COAL TAR ENAMEL 2 COATS AND OTHER SURFACES NOT 16 MILS OTHERWISE DESIGNATED TO BE CEMENT MORTAR COATED. ALL SURFACES 10 BE PAINTED OR COATED SHALL BE PROPERLY CLEANED WITH APPROVED EQUIPMENT BEFORE APPLICATION OF COATING MATERIALS. THE REMOVAL OF OIL OR GREASE SHALL BE ACCOMPLISHED WITH SUITABLE SOLVENTS BEFORE MECHANICAL CLEANING IS STARTED. ANY GRIT OR DUST REMAINING ON THE SURFACE FROM THE CLEANING OPERATIONS SHALL BE REMOVED BEFORE COATING MATERIALS ARE APPLIED. 6.1 ALL FACILITIES TO BE INSTALLED ON THE CITY OF BAKERSFIELD DOMESTIC WATER SYSTEM MUST BE INSTALLED BY A CONTRACTOR APPROVED BY THE CITY AND NO PART OF THE WORK MAY BE SUBLET WITHOUT THE APPROVAL OF THE CITY. CONTRACTOR MUST HAVE A CURRENT AND VALID LICENSE ISSUED BY THE STATE OF CALIFORNIA FOR THE CONSTRUCTION OF WATER SUPPLY MAINS AND RELATED FACILITIES. ACCEPTABLE CLASSIFICATIONS WILL CONSIST OF EITHER AN "A" LICENSE (GENERAL ENGINEERING CONTRACTOR) OR A "C-34" LICENSE (PIPELINE CONTRACTOR). 6.2 TRENCHING: TRENCHING SHALL NOT OCCUR PRIOR TO CURB AND GUTTER INSTALLATION WITHIN THE TRACT BOUNDARY. THE MINIMUM WIDTH OF TRENCH SHAL_ BE THE OUTSIDE DIAMETER OF THE PIPE PLUS 12 INCHES. A MINIMUM OF 6 INCHES OF CLEARANCE SHALL BE PROVIDED FROM THE OUTSIDE FACE OF THE PIPE TO THE TRENCH WALL. EXCESSIVE TRENCH WIDTHS GREATER THAN 16 INCHES MORE THAN THE PIPE OUTSIDE DIAMETER SHALL BE AVOIDED WHENEVER POSSIBLE. 6.2.1 PIPE DEPTH: FOR WATER MAINS AND SERVICES 12 INCHES AND LESS IN INSIDE DIAMETER, A MINIMUM OF 42 INCHES OF COVER FROM TOP OF PIPE TO FINISHED GRADE, OR FOR PIPE LOCATED WITHIN STREETS, A MINIMUM OF 42 INCHES OF COVER FROM TOP OF PIPE TO GUTTER FLOWLINE, SHALL BE MAINTAINED. FOR WATER MAINS LARGER NAN 12 INCHES IN DIAMETER, 48 INCHES OF COVER SHALL BE MAINTAINED, MEASURED FOR THE VARIOUS PIPE LOCATIONS AS DEFINED IN THIS SECTION. 6.2.2 WHEN WATER MAINS CROSS ROADWAYS THAT HAVE NOT BEEN CONSTRUCTED TO FULL ULTIMATE WIDTH, ADEQUATE TRENCH DEPTH SHALL BE PROVIDED SUCH THAT MINIMUM COVER REQUIREMENTS AS STATED ARE SATISFIED WHEN THE ROADWAY IS CONSTRUCTED TO ITS ULTIMATE WIDTH. 6.2.3 TRENCH BOTTOM: THE BOTTOM OF TRENCH SHALL BE EXCAVATED TO THE ESTABLISHED GRADE LINE OF THE PIPE AND SHALL BE SMOOTH, EVEN AND FLAT FOR THE ENTIRE WIDTH OF TRENCH. AT EACH JOINT OF PIPE THE BOTTOM OF THE TRENCH SHALL BE RECESSED IN SUCH A MANNER AS TO BELIEVE THE PIPE BALL OR COUPLING OF ALL LOAD AND TO ENSURE CONTINUOUS BEARING ALONG THE PIPE BARREL. WHERE EXCAVATION ENCOUNTERS BOULDERS, ROCK, HARDPAN, OR OTHER HARD OR UNYIELDING MATERIAL, THE TRENCH SHALL BE EXCAVATED A MINIMUM OF 6 INCHES BELOW THE ESTABLISHED GRADE, AND BACKFILLED TO PROPER GRADE WITH MATERIAL ACCEPTA3LE TO THE DEPARTMENT. BACKFILL MATERIAL SHALL BE COMPACTED TO 90% OF RELATIVE COMPACTION. WHERE EXCAVATION ENCOUNTERS SOFT, UNSTABLE, OR EXCESSIVELY `NET MATERIAL, SUCH MATERIAL SHALL BE REMOVED TO A DEPTH AS DIRECTED BY THE ENGINEER, AND REPLACED WITH MATERIAL ACCEPTABLE TO THE DEPARTMENT. 6.2.4 NUISANCE WATER: PIPE TRENCH AND ANY OTHER EXCAVATION SHALL BE KEPT ENTIRELY FREE OF WATER UNTIL ALL PIPE HAS BEEN PLACED AND APPROVED. WAT=R SHALL BE DISPOSED IN SUCH A MANNER AS TO NOT CAUSE INJURY TO PUBLIC OR PRIVATE PROPERTY, NOR CREATE A PUBLIC NUISANCE. 6.2.5 BACKFILL: BACKFILL SHALL BE INITIALLY PLACED AND COMPACTED FROM THE PIPE BED OR FOUNDATION TO THE "SPRINGLINE" OF THE PIPE. BACKFILL SHALL BE SUFFICIENTLY RODDED OR HAND -TAMPED TO ENSURE REQUIRED COMPACTION IS OBTAINED ON ALL SIDES OF THE PIPE. SUBSEQUENT BACKFILL SHALL BE PLACED IN LAYERS NOT EXCEEDING 6 INCHES IN COMPACTED THICKNESS, AND SHALL BE COMPACTED BY APPROVED METHOD SO AS TO NOT CAUSE INJURY OR DISTURBANCE OF THE PIPE. FLOODING OF TRENCHES MAY BE PERMITTED BY THE DEPARTMENT PROVIDED FOUNDATION AND BACKFILL MATERIAL IS SUFFICIENTLY GRANULAR AND OPEN GRADED IN NATURE SUCH THAT REQUIRED COMPACTION MAY BE OBTAINED. BACKFILL MATERIAL SHALL 13E FREE OF ALL TRASH, DEBRIS, ROCKS LARGER THAN 3/4" IN ANY DIMENSION, ORGA VIC OR OTHER DELETERIOUS MATERIAL COMPACTION SHALL BE OBTAINED IN ACCORDAN �IE WITH THE STANDARD DETAILS. MAXIMUM DENSITY AND OPTIMUM MOISTURE SHALL BE DETERMINED IN ACCORDANCE WITH ASTM D-1557. COSTS OF COMPACTION TESTING SHALL BE BORNE BY THE CONTRACTOR AND SHALL BE PERFORMED BY A COMPANY OR INDIVIDUAL PROPERLY LICENSED TO PERFORM SUCH WORK. 6.2.6 TRENCH SAFETY: EXCAVATIONS SHALL BE SUPPORTED IN CONFORMANCE WITH THE RULES, ORDERS, AND REGULATIONS OF THE INDUSTRIAL ACCIDENT COMMISSION AND THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA. 6.3 PIPE PLACEMENT & MATERIAL HANDLING: ALL PIPE AND PIPE MATERIAL SHALL BE HANDLED, STORED, LAID, BLOCKED AND JOINED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS EXCEPT AS OTHERWISE PROVIDED IN THE STANDARD DETAILS AND THESE SPECIFICATIONS. 6.3.1 EVERY PRECAUTION SHALL BE TAKEN TO PREVENT FOREIGN MATERIAL FROM ENTERING THE PIPE DURING INSTALLATION. ALL OPEN ENDS OF PIPE SHALL BE PRO'ERLY COVERED AT THE END OF EACH DAY TO PREVENT THE ENTRY OF FOREIGN MATTER, ANIMALS OR CHILDREN. NO TOOLS, RAGS, OR OTHER EQUIPMENT SHALL BE PLACED IN THE PIPE DURING INSTALLATION. 6.3.2 HANDLING: HOISTING OF PIPE BY MECHANICAL MEANS SHALL REQUIRE USE OF A CLOTH BELT OR CONTINUOUS FIBER ROPE THAT DOES NOT SCRATCH THE PIPE SURFACE. PIPE SHALL BE CAREFULLY LOWERED INTO TRENCH SUCH THAT PIPE BEDDING OR FOUNDATION WILL NOT BE DISTURBED AND PIPE WILL NOT BE INJURED. ANY PIPE THAT IS MARRED, CRACKED, OR SCRATCHED FORMING A CLEAR DEPRESSION SHALL BE REJECTED. 6.3.3 DUCTILE IRON FITTINGS: DUCTILE IRON FITTINGS SHALL BE LOWERED INTO TRENCH BY MECHANICAL MEANS. DUCTILE IRON FITTINGS SHAL'_ BE RUNG WITH A LIGHT HAMMER WHILE SUSPENDED TO DETECT CRNCKS, AND SHALL BE INSPECTED 17 OR SCRATCHES OF THE SURFACE COATING AND OTHER DEFECTS. ANY MATERIAL REJECTED SHALL BE PROM'TLY REMOVED FROM THE SITE AND SHALL BE REPLACED WITH SUITABLE MATERIAL. WHEN THE SEAL BETWEEN THE PIPE AND THE BELL END OF THE FITTING IS MADE WITH A RIGID JOINTING MATERIAL, THE LENGTH OF THE PIPE SHALL NOT EXCEED 3 FEET, 3 INCHES FOR PIPE 6 INCHES AND LESS W INSIDE: DIAMETER. WHEN PIPE IS 9 INCHES AND MORE IN DIAMETER, THE LENGTH OF THE PIPE SH/ALL NOT EXCEED 6 FEET, 6 INCHES. WHEN A RUBBER RING -TYPE CAST-IRON FITTING IS USED TO MAKE THE: JOINT, LENGTHS OF PIPE UP TO 13 FEET MAY BE USED FOR ENTERING BELLS OF FITTINGS. 6.3.4 STORAGE: PVC PIPE SHALL NOT BE STACKED HIGHER THAN 4 FEET NOR STACKED WITH WEIGHT ON THE BELLS. IF PVC PIPE IS STORED FOR PROLONGED PERIODS IT SHALL BE PROTECTED FROM ULTRAVIOLET LIGHT BY COVERING. 6.3 .5 P.V.C. PIPE INSTALLATION: THE MANUFACTURER'S RECOMMENDATIONS SHALL BE STRICTLY ADHERED TO EXCEPT AS OTHER\MSE PROVIDED HEREIN. THE BELL AND SPIGOT SHALL BE THOROUGHLY WIPED CLEAN JUST PRIOR TO COUPLING. THE RUBBER G/,SKET SHALL BE INSERTED, AND THE SPIGOT END SHALL BE LUBRICATED JUST PRIOR TO JOINING PIPES. THE RUBBER RING GASKET SHALL BE CHECKED FOR PROPER PLACEMENT WITH A FEELER GAGE AFTER JOINING PIPE. 6.3.7 SETTING VALVES AND VALVE BOXES: VALVES SHALL BE SET TRULY PLUMB WITH VALVE BOXES DIRECTLY OVER THE WRENCH NUT OF THE VALVE. THE VALVE BOX SHALL NOT TRANSMIT SHOCK OR STRESS TO THE VALVE. AFTER BEING CORRECTLY POE TIONED FOR LINE AND GRADE, EARTH FILL SHALL BE CAREFULLY TAMPED AROUND THE VALVE BOX. 6.3.8 SETTING AIR AND VACUUM RELIEF VALVE INSTALLATIONS: THE GATE VALVE IMMEDIATELY BELOW THE RELIEF VALVE SHALL BE SET TO THE GRADE INDICATED ON THE DRAWINGS OR APPROVED BY THE ENGINEER. SUFFICIENT CLEARA14CE SHALL BE PROVIDED BELOW THE VALVE FOR THE INSTALLATION OF A CONCRETE PAD TO SUPPORT A PROTECTIVE ENCLOSURE. 6.3.9 SETTING HYDRANTS AND ANGLE FIRE PLUGS: ALL HYDRANTS SHALL STAND PLUMB AND SHALL HAVE THEIR NOZZLES PARALLEL WITH OR AT RIGHT ANGLES TO THE CURB, WITH THE PUMPER NOZZLE FACING THE CURB, EXCEPT THAT HYDRANTS HAM14G TWO HOSE NOZZLES 90 DEGREES APART SHALL BE SET WITH EACH NOZZLE FACING THE CURB AT AN Al\ GLE OF 45 DEGREES. HYDRANTS SHALL BE SET TO THE ESTABLISHED GRADE EXCEPT THAT WHERE NOT SHOWN, NOZZLES SHALL BE AT LEAST 18 INCHES ABOVE GROUND. UNLESS OTHERWISE NOTED ON THE DRAWINGS OR DIRECTED, EACH HYDRANT SHALL BE CONNECTED TO THE MAIN WITH A E, INCH BRANCH UNE CONTROLLED BY AN INDEPENDENT 6 INCH GATE VALVE. THE BOWL OF EACH HYDRANT SHALL BE WELL BRACED AGAINST UNDISTURBED EARTH AT THE END OF THE TRENCH WITH CONCRETE BACKING., EACH ANGLE FIFE PLUG SHALL BE CONNECTED TO THE MAIN WITH A 4 INCH BRANCH LINE:, CONTROLLED 13Y AN INDEPENDE VT 4 INCH GATE VALVE. ANGLE FIRE PLUG SHALL BE SET WITH THE 2-1/2 INCH OUTLET FACING THE CURB AND SHALL BE SET TO ESTABLISHED GRADE EXCEPT, THAT WHERE NOT SHOWN, NOZZLE SHALL_ BE AT LEAST 18 INCHES ABOVE GROUND. 6.3.10 CONCRETE THRUST BLOCKS: CONCRETE THRUST BLOCKS SHALL BE INSTALLED ACCORDING TO THE STANDARD DETAILS AND SHALL BE PDURED BETWEEN UNDISTURBED GROUND AND THE FITTING TO BE ANCHORED. THE CONCRETE SHALL BE PLACED SUCH THAT THE PIPE, VALVES, AND FITTINGS WILL BE ACCESSIBLE FOR REPAIRS. 6.4 BORING: ALL CROSSINGS REQUIR114C A PIPE BORE SHALL BE CASED AND COMPLY FULLY WITH THE REQUIREMENTS SET BY PLATE NO. 7 IN THESE SPECIFICATION. ALL PIPE SIZES TWO INCHES (2") AND LARGER SHALL REQUIRE BORING AND CASING. 7.2 HYDROSTATIC (LEAKAGE:) TEST: AFTER COMPLETION OF THE PIPELINE INSTALLATION, THE LINE SHALL BE TESTED UNDER THE HYDROSTATIC PRESSURE TEST OF 150 PSI FOR A PERIOD OF NOT LESS THAN 4 HOURS FOR EACH SECTION OF PIPE TESTED. THE PRESSURE SHALL BE MAINTAINED BY RESTORING THE TEST PRESSURE WHENEVER IT FALLS AN AMOUNT OF 25 PSL AT THE CONCLUSION OF THE 4 HOURS, THE TEST PRESSURE SHALL BE RESTORED AND ALL WATER USED DURING THE TESTS SHALL BE ACCURATELY MEASURED TO DETERMINE THE ACTUAL LEAKAGE. 7.2.1 THE CONTRACTOR SHALL PROVIDE SUITABLE CALIBRATED TANKS FOR MEASUREMENT OF LEAKAGE AND SHF+LL FURNISH NECESSARY BULKHEADS, PIPING, PUMPS, POWER, LABOR, AND SHALL PERFORM ALL WORK REQUIRED FOR FILLING THE PIPELINE AND FOR MAINTAINING THE REQUIRED WATER PRESSURE. THE DEPARTMENT OR INSPECTOR WILL PROVIDE CALIBRATED GAGES AND WILL MAKE NECESSARY READINGS. 7.2.2 THE CONTRACTOR, AT HIS OWN EXPENSE SHALL MAKE ALL NECESSARY REPAIRS OF THE WATER SYSTEM UNTIL THE PIPE IS FOUND TO BE SATISFACTORY. 7.2.3 ALLOWABLE 1_1=AKAGE RATE: RESOARDLESS OF THE RATE OF LEAKAGE, A DETECTABLE LEAKAGE POINT SOURCE SHALL BE =1XED. THE FOLLO`ING ARE MAXIMUM ACCEPTABLE LEAKAGE RATES FOR A.C. AND P.V.C. PIP1= OVER A 24 HOUR PERIOD. P.V.C. AND MOLECULARY ORIENTED P.V.C. PIPE: MAXIMUM ACCEPTABLE LEAKAGE RATE IS 10 GALLONS PER DAY PER INCH PIPE DIAMETER PER MILE OF PIPE OVER A 24 HOUR PERIOD. 7.3 DISINFECTION OF WATER LINES: AFTER HYDROSTATIC TESTING HAS BEEN COMPLETED, THE ENTIRE NEWLY CONSTRUCTED WATER SYSTEM, INCLUDING PIPE, VALVES, FITTINGS, HYDRANTS, AND OTHER ACCESSORIES SHALL BE DISINFEC TED IN ACCORDANCE WITH AWWA C-601 AND THE MOST RECENT STANDARDS AND SPECIFICATIONS FOR DOMESTIC WATEF' SYSTEMS FOR THE CITY OF BAKERSFIELD. 7.5 FIRE FLOW TEST: THE CITY OF BAKERSFIELD FIRE DEPARTMENT WILL TEST NEWLY CONSTRUCTED WATER SYSTEMS TO DETERMINE IF MINIMUM STANDARDS FOR THE FIRE FLOW HAVE BEEN MET. 7.6 COSTS FOR TESTING: THE CONTR NCTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH THE VARIOUS ACCEPTANCE TESTS AND ANY NECESSARY REPAIRS, EXCEPT AS OTHERWISE STATED IN THESE SPECIFICATIONS. Q±SITE WATER SPECIFICATIONS THE FOLLOWING NOTES SHALL APPLY TO THE ONSITE WATER SYSTEM (INCLUDING FIRE SERVICE) FRCM THE SERVICE CONNECTION TO THE BUILDING. ALL OTHER ASPECTS OF THE ONSITE WATER SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE CITY OF BAKERSFIELD STANDARDS AND SPECIFICATIONS FOR DOMESTIC WATER SYSTEMS, CURRENT EDITION. 1. CONTRACTOR SHALL FURNISH ALL MATERIALS, TOOLS, LABOR, EQUIPMENT, SUPERVISION AND TESTING NECESSARY FOR A COMPLET17 INSTALLATION OF THE WATER SYSTEM. 2. WATER PIPE 4" AND LARGER SHALL HEET THE REQUIREMENTS OF AWWA C900, CLASS 150. JOINTS SHALL HAVE ELASTOMERIC GASKETS AND CONFORM TO ASTM D3139. WATER PIPE 3" AND SMALLER SHALL CONFORM TO ASTM U1785 SCHEDULE 40 AND SHALL HAVE SOLVENT WELDED JOINTS. PIPE SHALL BE INSTALLED IN CONFORMANCE WITH MANUFACTURER'S RECOMMENDATIONS. 3. FITTINGS FOR AWWA C900 PIPE SHALT_ BE DUCTILE IRON CONFORMING TO AWWA 150. FITTINGS FOR SCHEDULE 40 PIPE SHALL CONFORM TO ASTM D2466 SCHEDULE 40. 4. GATE VALVES SHALL BE AWWA C509 WITH RESILIENT SEATS. 5. THE MINIMUM WIDTH OF TRENCH SHALL BE THE OUTSIDE DIAMETER OF THE PIPE PLUS 12". A MINIMUM OF 6" OF CLEARANCE SHALL, BE PROVIDED FROM THE OUTSIDE FACE OF THE PIPE TO THE TRENCH WALL. WATER LINES ANC SERVICES SHALL HAVE A MINIMUM OF 30" OF COVER FROM THE TOP OF PIPE TO FINISHED GRADE. THE BOTTOM OF THE TRENCH SHALL BE EXCAVATED TO THE ESTABLISHED GRi0E UNE OF THE PIPE AND SHALL BE SMOOTH, EVEN AND FLAT FOR THE ENTIRE WIDTH OF THE TRENCH. AT EACH JOINT THE BOTTOM OF THE TRENCH SHALL BE RECESSED IN SUCH A MANNER AS TO RELIEVE THE PIPE BELL OR COUPLING OF ALL LOAD AND TO ENSURE CONTINUOUS E EARING ALONG THE PIPE BARREL. 6. BACKFILL SHALL BE INITIALLY PLACED AND COMPACTED FROM THE PIPE BED TO THE SPRING LINE: OF THE PIPE. 13ACKFILL SHALL EE SUFFICIENTLY RODDED OR HAND -TAMPED TO ENSURE REQUIRED COMPACTION IS ACHIEVED j�ROUND THE PIPE. SUBSEQUENT BACKFILL SHALL BE PLACED IN LAYERS NOT EXCEEDING 6" IN COMPACTED THICKNESS. EMBEDMENT MATERIALS SHALL BE CLASS I OR II PE=R A.S.T.M. D2321, MAX SIZE=1 ". 7. INS71-ALL 3" WIDE BLUE MAGNETIC DETECTION TAPE MARKED "WATER" AS MANUFACTURED BY MAC NATEC 12" ABOVE WATER LINES. 8. BACKFLOW PREVENTION DEVICES SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATION AND IN ACCORDANCE WITH CITY OF BAKERSFIELD STANDARD PLATES. REQUESTS FOR SUBSTITUTION OF DEVICES MUST BE _�UBMITTED PRIOR TO BIDDING AND MUST BE APPROVED BY THE ENGINEER AND THE CITY WATER MANAGER. 9. THRUST BLOCKS SHALL BE {NSTALLED PER C.0.6. PLATE W-2. S 0 c 0 0 3 d U �r N i N i z a 0i 14- N U a i N 0 0- E i 0 !; "> W \ \ \ \ DRAINAGE \\ `------.—_.._------ SUMP , I 21 I 20 � 20 \ 1527 7 I 25 ; 24 I 23 { 2 I i { i� I \ \ `i-------------------------------- 1 1 I I I f I { � ► \,� \ �- – �X EX W EX W — — — — — EX W — -- — EX W -- = — — — — — — EX W —. — — — — EX W — — -- — -- EX W — — — — _ _ EX W — — — — W ------=----dam--_ ---------------------------- _ _-- -- -- --- L _ ---_ _--- ---- — _----__ = ---_ __.— _----- = ---- _ = ---- ---- _-- _ _ WHITE LANE I L------- F----- -- -----_e-________-_ 0 lI� + 7 !� D \ (B s 5 W / / / / 3 2 12 13 ��----- ^--�— BLUE _GRASS INSTALL 171.2 LF.t 8' PVC WATER MAIN -INSTALL 22.3 LFt 8" PVC WATER MAIN ll 1a 27 28 2 26 29 / 43 38 25 24 30 31 lV 23 32 14 LANE 15 INSTALL 659.3 L.F.t 8' PVC WATER MAIN 22 33 21 34 16 17 ! �l j� 18 " U oaUo mv� r, w8wz wow_a -ver t - wow d w Z cn nid' zpz&= w0 wmwr-♦� cb to co Z0W=1S=5Zm W Z `` wwow wupiv�LL'61- N zcF-i'=`i'o��� t�3 Zvi wW:)ZOi-opt �oaw'p�z�2�� U a<tf-�- m d7" �o3LL�§o�ewu �� viwgwwv��zp rn C�fr LL zc��paa zzo0w �Lr//) (7 (D a. rV _o wZ�waOa'idQvwiwwww4Z►=-WI CD NN0ozo2m 06a�5 Ooz�cro2> � pcpso8a WwxF=¢wvzZa Zpw Cl8ca W W ul— 2w w ZwwV°u5p0 � CSI a. m>apLuW t O r mw�=F-ac�zc� 0-Ir,Oou.2LuWrc mFi- �TtAx�UoaWLL1 J O U' tq�S�U>Q uuiip= ¢~OwwNm�p aOpq}�Vp55 Zyo!dm .....t i Q�o�iZiiC�7>ifL>F- W W U O W Z w> y �t=-aa+=-002ad� G N k �I j�—.--•.�--®. GATE VALVE w/SIZE (PER CITY OF BAKERSFIELD SPECIFICATIONS) 1 r� +� ®------ 2" STANDARD SERVICE CONNECTION -UNLESS NOTED OTHERWISE (PER C.O.B. STD. DWG. W-8) FIRE -HYDRANT ASSEMBLY (PER C.O.B. STD. :WG. W-3) ® o BLOWOFF ASSEMBLY (SEE MATERIAL LEGEND FOR PAVED OR UNPAVED) PROPOSED WATERLINE w/SIZE HJ it z ao /II --•—jam}— PROPOSED WATER VALVE C: — (� Pw PROPOSED WATERLINE PER PARCEL MAP 121 CO IMPROVEMENT PLANS 0 z E 10' WATER UNE EASEMENT 20 35 10' WATER UNE EA N —'--- I M -00 -INSTALL 63.5 LFt —I LAUREN - COURT 8" PVC WATER MAIN toOD 0 INSTALL 412.0 LF:t 8' PVC WATER MAIN iv INSTALL 228.3 LF.f 8' PVC WATIR MAIN 42 37 41 36 N 40 PHASE 2 35 34 SEE SHE=ET 4 38 33 37 �+ 1 PROPOSED WATER VALVE PER PARCEL MAP 12100 IMPROVEMENT PLANS a L3 �� p j U1 �� LL w -tEx ,�,.-- --- EXISTING WATERLINE p_ " U. C. o <a 5 // / - -- - �� --- -- EXISTING WATER VALVE H 1 Z / S - PROPOSED SEWER MAIN / QO s ___. __- PROPOSED SEWER PER PARCEL MAP 12100 IVPROVEMENT PLANS Qom. <� Lam' PROPOSED STORM DRAIN MAIN // —�—� a // / = PROPOSED STORM DRAIN PER PARCEL MAP '12100 IMPROVEMENT PLANS ins 3 '� >I v --GAS-- EXISTING GAS MAIN/ , d U 19RIGHT-OF-WAY R/w STREET RIGHT -OF -WAY � APPROXIMATE LENGTHS, CONTRACTOR SHALL VERIFY ALL PIPE LENGTHS PRIOR TO BIDDING THIS PROJECT. MATERIAL LEGEND �✓ �// //r Q 8" TEE 8" GATE VALVE 8" 90- ELL 8" 45- ELL FIRE HYDRANT BLOWOFF ASSEMBLY (PAVED AREA) (PER C.O.B. STD. DW(;. W-4) END OF LINE BLOWOFF ASSEMBLY - UNPAVED AREA (PER C.O.B. STD. Q DWG. W-6) REMOVE EXISTING BLOWOFF ASSEMBLY (PER PARCEL MAP 12100 PLANS) 1 AND TIE INTO EXISTING WATER MAIN. Q. CONSTRUCTION NOTES C. �v CA REMOVE EXISTING WHARF HYDRANT AND CONNECT TO EkSTING 8 WATER 1� ! r \\ MAIN (CONTRACTOR SHALL VERIFY EXACT LOCATION AND DEPTH IN FIELD). iii LIJ �\ \\ G INSTALL CURB &GUTTER PRIOR TO WATER MAIN INSTALIj�TIONS. � •roma S�. \ \ \ \\ Q3 NO OTHER UTILITIES IN CITY WATER MAIN TRENCH OTHER THAN C C PERPENDICULAR CROSSINGS WITH 1' SEPARATION (MINIMUAI) END PHASE 1 CONSTRUCTION. TO BE EXTENDED WITH FUTJRE PHASE t CONSTRUCTION. PROPOSED 10' WIDE WATER LINE EASEMENT TO BE DEDIC�.TED ON FINAL MA ct 36 \ \ \ \\ c LoL 0) O 013 Q t'7 v r - w C1r C14 I ct u Q N F Q a a c -N- u N LL: o CI,ATE 9/(.15/2(314 i C'4 JOE3 Nci 1:3.27��+)H NORTH � �HEE1" o SCALE: 1 "= 50' t i 0 25 50 100 = 0 L — — LPHASE 2 os�� w0r4 SEE SHEET 4� �- 10w w� W a PHASE 1 vim'awiw Rru I al 0c -zo t)z zo �VO Ml O cr F wwO�x r==.OW7-12 \� 3PA 6 35 34 �3�►-��o5 I= 33 a�a�5�z�°W� 37 af�oa�a��w=z ui 'dtlfjelw5w .. 10 \\ \ aW � z t �� / x oo �zz+L ��zzw000m 14 160 Lu �A WAY �W�a�c�wZOO E-10 r F.t _ $" PVC WATER MAIN iv 0 O W tOi INSTALL 3929 _ &6 w y co ME I ¢ 0 \ / 000— � Z �!26 �`` ww wOm co n —� �� /' /i / ► N. / ww 025 Owz cn>-� rj KCE- 24 60 3032 31\ 30 ,i r .// \ \\ \ !r \ ^ Oc75— t 4� / C �_ \\ 22 \ 7�, / �4' 28 3 / 4 / \ 5 \\ INSTALL 22.4 LFt \ 8" PVC WATER MAIN / D \\ 6 7 �y \ / 8 W" WP�R a 13 0 12 N 15 17 21 1ti 29 i� X '9 20 \ cv, % oL \\ \ 19 / ' // / 18 Cie, -N- 4/1 41 /�� ; NORTH V' Z :> Lc C/) ca c WI _Z i_ ti_ > 01N Q � ' in LL zLu x co oa Z iu a n U) CN W W �� ~ CD N lw 1 �a CI: N Lil i a li L2' Lu C -i w = i/ z ti. C Lu z: LLi CI L) v; LiI � LL� W a y U. i. C a �G.LR�1, f 00 cn a �. (� w V V SCALE: 1 "=50' z FM 0 25 50 100 1',c)' CL 'qq':r C CA� W qlv� U r`/ / 1 G <- _1_ w loj< C.L. 1� W LEGEND MATERIAL LEGEND --- - — ' 10 �� ��--_ ,, SCALE: 1 "=50' FM 0 25 50 100 v LEGEND MATERIAL LEGEND --- - — M 104 GATE VALVE w/SIZE (PER CITY OF BAKERSFIELD Sf'1=CIFICATIONS) 8" TEE 8" GATE VALVE / �--- 2" STANDARD SERVICE CONNECTION -UNLESS NOTED OTHERWISE 8" 90" ELL N / (PER C.O.B. STD. DWG. W-8) �D 8" 45- ELL \ --- FIRE -HYDRANT ASSEMBLY (PER C.O.B. STD. DWG. W-3) �E FIRE HYDRANT / \\ •---- BLOWOFF ASSEMBLY (SEE MATERIAL LEGEND FOR F/ VED OR UNPAVED) BLOWOFF ASSEMBLY (PAVED AREA) (PER C.O.B. STD. DWG. W-4) \ \ PROPOSED WATERLINE w/SIZE END OF LINE BLOWOFF ASSEMBLY — UNPAVED AREA (PER C.O.B. STD. w --{ja- PROPOSED WATER VALVE PW PROPOSED WATERLINE PER PARCEL MAP 12100 IMPROVEMENT PLANS -{id--- PROPOSED WATER VALVE PER PARCEL MAP 12100 IMPROVEMENT PLANS -EX w- -- EXISTING WATERLINE - - -t>Q - - EXISTING WATER VALVE s PROPOSED SEWER MAIN - - s - - PROPOSED SEWER PER PARCEL MAP 12100 IMPROVEMENT PLANS _ = PROPOSED STORM DRAIN MAIN - _ - - - PROPOSED STORM DRAIN PER PARCEL MAP 12100 iIAPROVEMENT PLANS - -GAS- - EXISTING GAS MAIN R/W STREET RIGHT-OF-WAY t APPROXIMATE LENGTHS, CONTRACTOR SHALL VERIF( ALL PIPE LENGTHS PRIOR TO BIDDING THIS PROJECT. DWG. W--6) N REMOVE EXISTING BLOWOFF ASSEMBLY (PER PARCEL MAP 12100 PLANS) AND TIE INTO EXISTING WATER MAIN. co Z Gi J �1 CONSTRUCTION NOTES CN � L3 0 REMOVE: EXISTING WHARF HYDRANT AND CONNECT EXISTING 8" WATER MAIN (CONTRACTOR SHALL VERIFY EXACT LOCATION AND DEPTH IN FIELD). o "�'�"'"'�' [ )ATE INSTALL. CURB & GUTTER PRIOR TO WATER MAIN INSTALLATIONS. i F'A JOB No. 03 NO OTHER UTILITIES IN CITY WATER MAIN TRENCH OTHER THAN NEE, PERPENDICULAR CROSSINGS WITH 1' SEPARATION (KNNIMUM) E v ® END PHASE 1 CONSTRUCTION. TO BE EXTENDED W111-4 FUTURE PHASE CONSTRUCTION. E i t�5 PROPOSED 10" WIDE WATER LINE EASEMENT TO BE CEDICATED ON FINAL MAP a 1 f__ s N Of