Loading...
HomeMy WebLinkAbout1.8-6557 Ph 2Fol � 2 3 4 5 6 � 7 8 10 J d 14' 9' Ld 3 _Z J VARIES WALL Li 3.5'-6' W U TRENCH AT BOW TRENCH CENTERLINE MOUNTAIN RIDGE DRIVE NO SCALE 10' PUE PAD -MOUNTED EQUIPMENT SUBSURFACE ENCLOSURE J a 10' z J oc 5' OR 6' z 1' w U TRENCH CENTERLINE C A TYPIL INTERIOR STREET NO SCALE (TRENCH IN FRONT OF ROW) LOT LINE LOT LINE V-6" c�••� _ I _ w GSTC STUB o / \ N aT �-- — —I — — co WATER METER MAIN TRENCH 0 .n B i w a LOT LINE I( TYPICAL INTERIOR STUB INSTALLATION NO SCALE (TRENCH IN FRONT OF ROW) NOTE: ALL SERVICES AND SUB -STRUCTURES ARE NOT TO SCALE FOR CLARITY. ALL COMPONENTS SHALL FIT WITHIN THE PUE OR FRANCHISE AREA UNLESS OTHERWISE NOTED. REFER TO DETAILS FOR LOCATIONS. SUBSTRUCTURE VERIFICATION STAMP DEVELOPER PLEASE NOTE AND SIGN ALL P.G.& E. ENCLOSURES AND BOXES HAVE BEEN SET TO GRADE ACCORDING TO GRADE STAKES PROVIDED BY DEVELOPERS ENGINEER. ALL COSTS TO RELOCATE OR RE -ADJUST BOXES AT A LATER DATE WILL BE BILLED TO THE DEVELOPER. PLEASE HAVE YOUR JOB SUP. VERIFY THE CORRECTED GRADE OF ALL ENCLOSURES AND BOXES. AND SIGN AND DATE DRAWING. THANK YOU SIGNED DATE R/W R/W 24" WIDE (COMMON) J 14' 9' 3.1 W cr_WALL Z J ' L 6 NOTCH WALL Z TO MAI NTAI N v 1. 3' MIN. PAD -MOUNTED EQUIPMENT TRENCH CENTERLINE TRENCH AT BOW BERKSHIRE ROAD zI � 10' J \ Ia -I 1 O'PUE NO SCALE - PAD -MOUNTED EQUIPMENT 1' �— 2' PROPOSED WATER T\\— TRENCH SUB -SURFACE ENCLOSURE CENTERLINE BURNISHED BRON-'E DRIVE NO SCALE (TRENCH IN REAR OF PUE) LOT LINE 1 -6'I LOT LINE GSTC STUB T C w I C MAIN TRENCH NS OD o II T R/W U O / ILi 7) CL b LOT LINE V-6" TYPICAL STUB INSTALLATION FINISH GRADE 30" MINIMUM IN _T FRANCHISE AREA 30" MINIMUM IN FRANCHISE AREA 12" SAND OVER TELE MIN •.. .. 2" OR 4" C..0 :. POSSIBLE 58" 2 OR 4" :. c•' : •' 12" MIN. TOP OF GAS LEVEL 3" MIN.",; WITH BOTTOM OF `v TELEPHONE OR TV'':''''::":: 2" or 4" SHADING 1) 2" SAND SHADING AROUND GAS & ELECTRIC IF SOIL IS NOT ROCK FREE 2) ONLY PARTIES PARTICIPATING IN U.S.A. ARE ALLOWED IN JOINT TRENCH 3) ANY PARTY EXCEEDING ITS TRENCH ALLOTMENT SHALL MAKE ARRANGEMENTS TO ENSURE THAT TRENCH WILL ACCOMMODATE ADDED FACILITIES 4 GAS TO GO ON SIDE OF TRENCH NEAREST STREET 5 TRENCH LAYOUT SHALL CONFORM TO UO STANDARD S5453. TYPI CAL DISTRIBUTION TRENCH NO SCALE NO SCALE (TRENCH IN REAR OF PUE) 18" MINIMUM JOINT TRENCH RECAP SEL i� 1E =R CDP P."P �`�`.L._ FRCM: G GAS "_ P -)NE P TRENCH OCCUPANTS DISTRIBUTION OR SERVICE TREK S ZE DEPT FOOTAGE BACKFILL SURFACE I GSTC DIST 24" x 59" 1,029' SPREAD 1 D RT GPTC DIST 24" x 59" 1,817' SPREAD j D'RT GPSTC DIST 2L" x 59" 3,509' SPREAD D1 RT GPC DIST 21-" 24" x x 59" 59" 129' 175' SPREAD SPREAD DIRT Di RT _ _GPSC DIST_ PSTC DIST 24" x 59" 26' SPREAD DIRT STC DIST i 24" x 59"341' m SPREAD j DIRT GT DIST 24" x 59" 1 74' SPREAD DIRT GC DIST 2L" x 59"17.9 T2 SPREAD DIRT SC_ DIST 2L" x 59" 65' SPREAD DIRT _ PC DIST 2 x 59" 168' SPREAD DIRT _PSC DIST DIST 24" x 59" 58' SPREAD D'RT _ G 24" x 59" 1,596' SPREAD I D', RT T_ DIST 2L" x 59" 233' SPREAD D RT C DIST 24" x 59" 1,129' `; SPREAD DIRT P DIST 2L" x 59"0' SPREAD DIRT GSTC SERV FRANCH 18" x 46" 2,3_22' SPREAD DIRT GSTC SERV PRIVATE 18" x 46"894' SPREAD DIRT G SERVICE 18' x 46° 211' SPR'AD 1 DIRT GSTC JSERV. COMP. 18" x 46" 4 325' SPREAD I DIRT 'AaLLar.om%J>E■r'!wd rL Lilltr9ii4Xrtr" fnLMMKIMMM03MEL ° W1f 24" (30" IN STREET) 42" MIN. 00 3,. 12 6" " 1) 2" SAND SHADING AROUND GAS & ELECTRIC MIN. IF NATIVE SOIL IS NOT ROCK FREE. 2) SEE OTHER DETAIL IF NON -PG&E c4S GSTREETIGHT IS IN ENCH 3) ONLY PARTIES PARTICIPATING IN L.S.A. ARE BEDDING MATERIAL ALLOWED IN THIS TRENCH 2" FIG. 2 (VIEW FACING DISTRIBUTION TRENCH) TYPI CAL SERVICE TRENCH_ NO SCALE NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL DRAWINGS FOR ELECTRIC FACILITY PLACEMEN—, DETAILS, AND CLEARANCES. GENERAL NOTES: 1. DEVELOPER TO DO ALL TRENCHING, SHADING, AND BACKFILLING. PER UO STANDARD S-5452. 2. PHONE AND CABLE TV FACILITIES ARE SUBJECT TO CHANGE AT THE DISCRETION OF THOSE COMPANIES. 3. PADS, BOXES AND OTHER FACILITES ARE NOT SHOWN TO SCALE. 4. GAS AND ELECTRIC FACILITIES WILL REQUIRE SAND SHADING IF NATIVE SOIL IS NOT ROCK---iEE. PG&E WILL INSPECT BACKFILL MATERIAL. TEL AND/OR CATV MAY ALSO REQUIRE 12" OF SAND BACKFILL. 5. GROUND TO BE WITHIN .2 FT OF FINISH GRADE PRIOR TO TRENCHING. 6. GAS AND ELECTRIC FACILITES REQUIRE AT LEAST 3' OF SEPARATION (1' UNDISTURBED SOIL) FROM PARALLEL RUNS OF WATER, SEWER, OR STORM DRAIN. 7. PRE -CONSTRUCTION MEETING REQUIRED TWO WEEKS PRIOR TO THE START OF INSTALLATION. 8. CALL U.S.A. AT LEAST 48 HOURS PRIOR TO TRENCHING (DIAL 811) 9. PG&E WILL ASSIST IN LOCATING ENDS OF EXISTING GAS MAINS. 10. DEVELOPER IS RESPONSIBLE FOR OBTAINING ENCROACHMENT PERMITS.. 11. STREETLIGHT LOCATIONS MAY HAVE CHANGED. REFER TO THE APPROVED STREETLIGHT IMPROVEMENT PLAN FOR STREETLIGHT INSTALLATION. 12. DEVELOPER SHALL CONTACT ALL INVOLVED PARTIES PRIOR TO MAKING ANY CHANGES FROM THIS DRAWING. 13. REFER TO EACH PARTY'S INSTALLATON INSTRUCTIONS FOR MORE PRECISE DESCRIPTION OF SUBSTRUCTURES AND OTHER REQUIREMENTS. _.EGEND: SEL i� 1E =R CDP P."P �`�`.L._ FRCM: G GAS "_ P -)NE P EL EC: --R C PR MA (661) S ELEC-�C SECJNDAR`' T T' TELE CINE 3. GREG EOF C - 395-3351 1 - i2.12 CIO.— PROPOSED S=R`v.CE -r' - B 13 PROWDS-D MAN L`lE _NC- TE' - t2 c 1 1 a 12 t2 ,E POE L3] PRODOS D #3 (��„ x �r ., x ' L_. -h. C ` FL:C- BJX L3_E] 1 12 12 c LNC_ -CS Lp t2 1 1 PROPOS_D _-ANLSCA-L 12 12 12 0 iu PROPOS__D CABLE PL :;E =?OX r\ m PRO1'JS3 DAD I,iL-iPa-E ! -RA` SF+`,?ti,'-R tos.�,irn. rtn iit 13:im12 G10'PSTC NDjCA�_S c 8 8 1 Q IWL T2 12 1 3 W-0 ..� 12 13 F2 12 a a 12 'AaLLar.om%J>E■r'!wd rL Lilltr9ii4Xrtr" fnLMMKIMMM03MEL ° W1f 24" (30" IN STREET) 42" MIN. 00 3,. 12 6" " 1) 2" SAND SHADING AROUND GAS & ELECTRIC MIN. IF NATIVE SOIL IS NOT ROCK FREE. 2) SEE OTHER DETAIL IF NON -PG&E c4S GSTREETIGHT IS IN ENCH 3) ONLY PARTIES PARTICIPATING IN L.S.A. ARE BEDDING MATERIAL ALLOWED IN THIS TRENCH 2" FIG. 2 (VIEW FACING DISTRIBUTION TRENCH) TYPI CAL SERVICE TRENCH_ NO SCALE NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL DRAWINGS FOR ELECTRIC FACILITY PLACEMEN—, DETAILS, AND CLEARANCES. GENERAL NOTES: 1. DEVELOPER TO DO ALL TRENCHING, SHADING, AND BACKFILLING. PER UO STANDARD S-5452. 2. PHONE AND CABLE TV FACILITIES ARE SUBJECT TO CHANGE AT THE DISCRETION OF THOSE COMPANIES. 3. PADS, BOXES AND OTHER FACILITES ARE NOT SHOWN TO SCALE. 4. GAS AND ELECTRIC FACILITIES WILL REQUIRE SAND SHADING IF NATIVE SOIL IS NOT ROCK---iEE. PG&E WILL INSPECT BACKFILL MATERIAL. TEL AND/OR CATV MAY ALSO REQUIRE 12" OF SAND BACKFILL. 5. GROUND TO BE WITHIN .2 FT OF FINISH GRADE PRIOR TO TRENCHING. 6. GAS AND ELECTRIC FACILITES REQUIRE AT LEAST 3' OF SEPARATION (1' UNDISTURBED SOIL) FROM PARALLEL RUNS OF WATER, SEWER, OR STORM DRAIN. 7. PRE -CONSTRUCTION MEETING REQUIRED TWO WEEKS PRIOR TO THE START OF INSTALLATION. 8. CALL U.S.A. AT LEAST 48 HOURS PRIOR TO TRENCHING (DIAL 811) 9. PG&E WILL ASSIST IN LOCATING ENDS OF EXISTING GAS MAINS. 10. DEVELOPER IS RESPONSIBLE FOR OBTAINING ENCROACHMENT PERMITS.. 11. STREETLIGHT LOCATIONS MAY HAVE CHANGED. REFER TO THE APPROVED STREETLIGHT IMPROVEMENT PLAN FOR STREETLIGHT INSTALLATION. 12. DEVELOPER SHALL CONTACT ALL INVOLVED PARTIES PRIOR TO MAKING ANY CHANGES FROM THIS DRAWING. 13. REFER TO EACH PARTY'S INSTALLATON INSTRUCTIONS FOR MORE PRECISE DESCRIPTION OF SUBSTRUCTURES AND OTHER REQUIREMENTS. _.EGEND: SEL i� 1E =R CDP P."P �`�`.L._ FRCM: G GAS "_ P -)NE P EL EC: --R C PR MA (661) S ELEC-�C SECJNDAR`' ATT (661) TELE CINE 3. GREG EOF C CABI.= _ V 395-3351 tfJ CC U W CIO.— PROPOSED S=R`v.CE -r' - > - — PROWDS-D MAN L`lE _NC- CD - Ex S N , UNDER ROUT :ACL__` c L2J PRO ' JS -_D ( ?" x 3 x 1 c '; 1 R L- BJ;< L2E,' PRO-OS=D #)C- 1 ; ° .' x _6") E __ -H C `SPL ,E POE L3] PRODOS D #3 (��„ x �r ., x ' L_. -h. C ` FL:C- BJX L3_E] PROPOS-D #3E 121"r ;C" x ''6» L_ C 7 C S'[ ";E -3_DX L5] PR0�05-D s U R S,'U 4-A 7- LNC_ -CS Lp PROPOS-J ##6 - ' x ';; »B- J� A''- �C'- 's 'T= PROPOS_D _-ANLSCA-L [T] PROPOS_3 -E_FI `-,NL -=Jrc ,aL''�,�P�C-}; 0 [C] PROPOS__D CABLE PL :;E =?OX r\ m PRO1'JS3 DAD I,iL-iPa-E ! -RA` SF+`,?ti,'-R o rtn PROPJSED PM ---9 PA N- _GrC R .A< F :c -D SVJ-. G10'PSTC NDjCA�_S c ��--- PROPOSED LS 24 PROPOSED SERV CE 1.0�L, ON FOR TRENCH INSPECTION CALL (559) 263-7312 ANY CHANGES TO THIS DESIGN MUST JOINT TRENCH COMPOSITE APPROVED BY: FIRST BE APPROVED BY PG&E. GAS ADE: GAS ADE: DOMINIC OTHART ELECT ADE: PHONE: (661) 398-5817 DATE: ALL FIELD C:-AN"ES SEL i� 1E =R CDP P."P �`�`.L._ FRCM: a COVP aNY "_ P -)NE i. LES INGLES P G & E (661) 398-3907 2. REGGIE SMITH ATT (661) 631-3473 3. GREG EOF BRIGHTHOUSE (661) 395-3351 PANAMA LN SITE BERKSHIRE RD o 2 En ~ z L_ HOSKING RD XI McCUTCHEN RD VICINITY MAP 6 5 4 NTS 3 un O z < w 0 C LL - O 0 LL - LL O 0 Cn< M O DO O O U T Z do QD U oho c'V rn co v y C CD � a � W Lij W C� — Q L v r W Z re"C o O CL. m LLC', L� tfJ CC U W CIO.— Z > E-+ CD -1 Q c �^ _ Cfl U a cc ci Q tvi � I 0 r\ m o c iVLi- a a u 1— => O O -� U U Z CD n LL vi U In 0 O 0 m to CV E 4 Lo Lo Z 0 x 00 Go s. Cn L to e., E --L r r 0 0_4zI4 E— "40 Lo L{� W z 0 0.4 TT - Z do QD U oho c'V rn co v y C CD � a m 0 N LJ I o — Q L v r W Z re"C o O CL. m LLC', L� tfJ CC U W CIO.— Z > E-+ CD -1 Q c �^ U a W ci Q tvi I m c a a CL vi 0 x Z 0 o 0 i LLJ O t/7 Z 2 1 W c.� 0 Z C\2 Q W Z re"C m F� CL. I�- 46 LLC', L� tfJ CC cr — 6rJ I� E-+ CIO.— U Y E-+ Li L:A O i LLJ O t/7 Z 2 1 1: "I Im i I z 1 X V) _j o TIE INTO EXISTING PRIMARY DUCTS BERKSHIRE ROAD _0 (CAUTION: EXISTING GAS) TIE INTO EXISTING 8" GAS MAIN P c PC 8* HIP PL GAS 69 go 10, 48' 109' -------------------- 77-7 . .... ... A", A 9 10 P_ tn LLJ 0:: W LLJ V) Q0 07) 0 L_ C=) C14 C) LL_ L: V F= CD 7: A c) :F , 1 , \11\ = C) = ........ .. `N�l .. .. ..... . "'M i=-. .. . ........ =... . . .. ............ . Z= ..... ..... =Z= ROPE TRENCH BEHIND EXISTING #7 VAULTC-4 E-, 47) 0 LO BERKSHIRE ROAD 1-4G 0 5' TIE INTO EXISTING 0)a re I-**-- c > Boo GAS MAIN (48i�' -:4 . . . . . . . . . . . ..... .............. 6' r ;9 C) C:> Go .. ...... ------ H? PL GAS P .............. C 61 ................ 549' 15' D LANDSCAPE Dsc 0 C1.4 E- a Ld 15' SERVICE 58' NOTCH WALL >. c" LOT 12 z. 1 LOT 11 LOT 10 o0 00 AS REQUIRED no E_ V) LOT 9 LOT 8 LOT 7 LOT 6 LOT 5 LOT 3 LOT 1 CPSC no C. 0 U, LOT 173 LOT 172 LOT 4 1 LOT 2 175' LOT 171 LOT 170 1 LOT 169 LOT 19 Li 1 u L . Ld z 5: 0 0 -11 ko V) Ld 0 w z z 5; L61 r- 1 Lo. A-/ _j LLJ OM ow Owl C) 0!! 1 60, 10, Zs Z!5 0 V) to, Z5 U) LLI _j W too LL1 V) W 10' * LL, _j En Wo W 41fl rx a- -0- LLJ EDO CO PUE u' C) LO PUE cn tog ;Z. 4 U) 10' 6' LOT 168 10, PUE E .............�PU L ­ 7 7� 7r- 20 F. 77W LO' E C14 .............. CZ> cm - - - --------- (0 7 L L .. .- i ; . CRYSTAL CASCADE LAN� 0 : I I ............ 7 S . ............. ....................... 00 ...... . ............... .......... .......... sa V2 6' Li LOT 167 _4J . ........... .. . ...... . ...... ... ......... . . . ....... . . ...... _7 – – ---- ........... - — ----- ------ r (1,; L!fj Ic 1c,41 76, "T- L �7 11 C-41 T {Ni C=� PST GSTC GPTc C:) 196' 61' 1 Wow 117' M PUE wd 10' w 5;\ 00f WN CWJ T STC 10 GPTC 1 C5) Ow 0 w 119 PUE ui W Ld w ox 0 of CD th cn 4 D ky CA U) En En tn cn m bi ox 0 0 V) V) L0 c bf Lu W Ly (n (n Ld 0 -,, La 0 —0 —0 1 -,, W cf) OSI cn / U, ui La W In cn —9 - 'i !6",- LOT 166 LOT 13 En ROPE TRENCH -o L I LOT 14 m 1' BEHIND no O�' SD BOX W LOT 15 LOT 16 1 LOT 17 LOT 18 LOT 20 LOT 21 LOT 22 1 LOT 23 LOT 24 LOT 162 LOT 163 LOT 164 0 LOT 19 N V) >_ >_ >_ >_ >_ � 00 no no an an LOT 165 00 LOT 161 280' En r ------- 10' PUE LOT 23 Cc PUE n LOT 35 LOT 34 n 0 L 60' LOT 33 LOT 32 LOT 31 LOT 30 LOT 29 LOT 28 LOT 27 LOT 26 W Wl LOT 25 LOT 160 1 W LOT 159 LOT 158 0 u � I. - LOT 157 LOT 1 1 Owl z 5; LOT 155 ow z 5: z 5; _j 0 W o X z 5; 5; V) _j uj _j uj owl w Z 5 ( cel 1 4� tn W_j W 7 fu W tn L. . 11. go 0 of En Ln Ln Lj Ui Ln O CO _j W _j uj A, ee-1 I I o OSS ui cn U3 En 4, 7� -V n to (D uj W Cn 10' LOT 36 LOT 211, 10' Sc UE 65' 3 L I—P f PUE = GT ------------ .......... ..... ... ........ 74 mmmmmmn T' ...... .......... . . ......... . ........ S10,6 Shql_T � LOT 37 LOT 38 PST 142' DWY 16' SHORT SIDE SERVICE LOT 39 10 UE -- — - -------- i IC> CL V) ............................. .o 3p U -------------- LOT 154 LANE 'ss --- -- ---------- -- 1 32 �ARIQIV CHANN 3 s GPTC 6 ......... ..... .......... . . ..... . 12' y .. ... ...... SHOR-f T 47. T -7 7 uj. 17 s_ L�J 1 C-41 L2 _PST 4� pW L_ L9J S�UE. SF RVICE L.2f J �CNI 131 GPc 3 62' LOT 153 u 10 w WN w \ 309' GPTc 05U\ / I b I u _� 7S3- 5 uj 5N Ir 5; CC) I uuj \ LOT En to Ld U.1 Lu 0 w 0 cn v) tn W uj 103 LOT 104 LOT 105 m cn 'LOT 6 V) En GPTC W U-1 -, W . V) V) N,�77' � 7 M En uj LOT 106 LOT 107 LOT 108 LOT 109 LOT 110 LOT ill LOT 112 LOT 113 LOT 114 LOT 115 LOT 116 En En En En Li r 'n 2 2 SHORT SCR V) :60:9E f SIDE SERVICE DWY > TW_y V L.LJ "�­LOT 152 no 10' 0 T _j 8' PUE �1. PST LOT 128 129' LOT 102 LOT 127 LOT 126 LOT 125 LOT 124 LOT 123 LOT 122 LOT LOT 1201 LOT 119 LOT 118 60' MATCH LINE A -A (SEE SHEET 3) LOT 151 MATCH LINE A -A (SEE SHEET 3) NOTE: ALL SERVICES AND SUB -STRUCTURES ARE NOT TO SCALE FOR CLARITY. ALL COMPONENTS SHALL FIT WITHIN THE PUE OR FRANCHISE AREA UNLESS OTHERWISE NOTED, REFER TO DETAILS FOR LOCATIONS. ';AL 811 SUBSTRUCTURE VERIFICATION STAMP DEVELOPER PLEASE NOTE AND SIGN ALL P.G.& E. ENCLOSURES AND BOXES HAVE BEEN SET TO GRADE ACCORDING TO GRADE STAKES PROVIDED BY DEVELOPERS ENGINEER. ALL COSTS TO RELOCATE OR RE -ADJUST BOXES AT A LATER DATE WILL BE BILLED TO THE DEVELOPER. PLEASE HAVE YOUR JOB SUP. VERIFY THE CORRECTED GRADE OF ALL ENCLOSURES AND BOXES. AND SIGN AND DATE DRAWING. THANK YOU SIGNED DATE NOTE- US--- THIS DRAW NG FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL DRAW NGS FOR ELF-----zRC FACILITY PLACEMENT, DETAILS, AND CLEARANCES. i 1v SCALE: 1 "=50' SCALE L 50' b' 50' 100' 5 0, LL_ LLJ L6j C\2 p,:1 z ck: m LL. cl- —T-7- C:) Ll LJ ck:: CO LL_ r-- E— C-) LL_ Lu 1,e- E .. 4 M _< LL cc Ld O (n LL_ L6j c:) m cl- —T-7- inun u IUD m W, 6' FROM ROW TIE INTO EXISTING 4" GAS MAI N AL 81 LOT 39 10' PUE DWY DWY 1TSHORT SIDE SERVICE / E_ LOT 40 PST ROPE TRENCH 126' l' BEHIND SD BOX GC lot 6p 129' PUE '0 LUSTROUS LANE LOT 100 _i /16' SERVICE DWY DWY LJ LOT 99 lot PUE LOT 98 L01 97 Owl_j L.0 o 41 LOT 12 7 � LOT 126 > LOT 125 LOT 124 LOT 123 LOT 122 LOT 121 Ld c-, () LLJ W Z!; cis 0 U 00 0: ' Z!-> ZS Ox 0 W _j uJ owl V) _j Ll cn _j LJ 101) Li (f) Lu Li (00 a (00 U) \U, ... ....... 10 MATCH LINE A -A (SEE SHEET 2) LLJ 8, V) 28 LOT 119 LOT 118 LOT 117 A 151 m r LOT 0 1 lul Z' lot z w I co 0 ui 0 (x V) tf) I PUE 21 ®2' SHORT Ld SIDE SERVICE DWY Fn M C:) (0 ... ...... LOT 129 ................. . . ... ......... .......... ...... _d/ 51 61 . . . . . . . . . . . . . . ... .. ..... ............ . . . ........ ............ -L4T Ar ............... 10 F_-1 EN L2J 1 C-41 L J L _J_ 10 c icf LLI 10 / 1 5-1\ PST GSTC PUE I Lui LIN GPTC 15 / w �ij:\ 0 m "gl000, Ox 0 Li 61' Li Ld Li Ld 243' CAW U) In En cn (n (n V) En Lu ui W LOT 130 a -0 -0 W -" Li En cn En 4" ul LOT 131 LOT 132 LOT 133 LOT 134 >_ LOT 135 LOT 136 LOT 137 LOT 138 LOT 139 LOT 140 LOT 141 o O0 0o ao 00 o0 10' PUE STC LOT 142 62 LOT 96 ILOT 95 I LOT 94 ILOT 93 I LOT 92 ILOT 91 LOT 90 LOT 89 I LOT 88 ops LOT 87I 24c 24 's Ol m _j �Lj q LWL-1 I I q LMIJ I I ON] N] in I U) min I U) LOT 74 I LOT 75 I LOT 76 I LOT 77 I LOT 78 I LOT 79 I LOT 80 I LOT 81 I LOT 82 LOT 83 10' PUE LOT 73 LOT 72 LOT 71 LOT 70 LOT 69 LOT 68 LOT 67 LOT 656 LOT 65 LOT 64 LU LL1 0 L) Ld L9 L) L) Z5 Z!-> owl 0 of zw OW W z 0 u En -i _j W _j LU _j uJ cn (n W () to LLJ to C3 LLJ coW LLJ Ln too PUE ... ................. -------- ... ............ 77777�; -7� ............. 7 :4 LOT 84 ........... ........... .. .. ..... . I . ........ .... . ............... . ..... ............ . ......... ..... TWINK LLANE 0 .......... sf.) '-.0 .................... o .................... . ......... ............ ... ................ IT09�d. lot 5s LOT 86 LOT 85 DWY DWY 16' SHORT SIDE SERVICE 10' LOT 143 A_m LOT 144 LJW T L C) _c LOT 150I ILA.- L: ID OT 20, L bc 01 O C" ............... ..... 2' SHORT SIDE SERVICE DWY 07E ­ LOT 149 I z 0 Ln LOT 30 ­!&_ 4 .............. GPTC 24' >< > GPTC 40 Qc) i 00 2 SHORT U cd C" 01 SIDE SERVICE DWY ...... tw 0 LOT 148 OT PST LE— > 31 0-4 Z LO 124' E lot m PUE -- — --------------- C) CL .3 LOT 147I LOT 3 a Q 8' DWY J cm r"r' DWY I I Q E C`4 GPC00 LOT 33 CO 24' #01� 621 LOT 146 U> C-4 SERVICE GP CA L> cn 43 m Ln co . . . ........ . . .... .... ................ ' 5 OR TIE INTO CD CL. EXISTING JT b 11-1 a- C-) (:I C/) a- .............................. PCC ... ..... . .. .. ... \_L9 COOL RUSH TERRACE 27 -AP PL ;6 TIE SERVICE :INTO 1 4 EXISTING GAS. � I � L DWY L DWY 167_"__SHORT - — I — —:-) \ SIDE SERVI�CE 2 Lij LOT 145 SERVICE [L TIE INTO IV EXISTING LOT 63 LOT 62 LOT 61 # Oxzi Z!5 GAS _j uJ _j uJ cn (n 40' TIE SERVICES SERVICE INTO EXISTING GAS 14' 'EXISTING) .... . ........ PL GAS L G IP HP P AS2" H , ........ .... .... ..... . .......... ........ .. .......... GO, ............................ $s 6' 6 40-69f 9 90 SERVICE 40' +_0 .......... F T L J I Lji T I C141 L _ hLe LJ L__j 1 NI PST PST STCSTC QSTCFUTURE SERVICE U.1) I u L 60 44' 16' STC L) brIL, 255' GPTC L W 52' 64' U L, PUE 10 36' 0 jr - 5N x C51N 5; of 5: 00: 0 0 X 10' 05 0 x Ld LJ W cn Ln En V) cn CA Lov' LOT 52 LOT 53 u.' L 0 T 54 LOT 55 '='uj LOT 56 7w V, xw LOT 51 l'W LOT 5 ui LOT 59 1-, En I (n n 3'x5' 60' V) I TEL cn 'n Lu 6 Li o o 3t B. LOT 58 00, Li ca ca 1 ro SCALE: 1 "=50' SCALE NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL DRAWINGS FOR ELECTRIC FACILITY PLACEMENT, DETAILS, AND CLEARANCES. 50' 01 50' 10( 6 5 4 3 2 cr 3 4 MATCH LINE A -A (SEE SHEET 2) 6 ---- - - ------ LOT 102 (. m 7 -7-7-t- C) INCH 0 LOT 128 60' k7 64 LTNG DWY DWY SIDE SERVICE M LOT 101 LOT 100 _i /16' SERVICE DWY DWY LJ LOT 99 lot PUE LOT 98 L01 97 Owl_j L.0 o 41 LOT 12 7 � LOT 126 > LOT 125 LOT 124 LOT 123 LOT 122 LOT 121 Ld c-, () LLJ W Z!; cis 0 U 00 0: ' Z!-> ZS Ox 0 W _j uJ owl V) _j Ll cn _j LJ 101) Li (f) Lu Li (00 a (00 U) \U, ... ....... 10 MATCH LINE A -A (SEE SHEET 2) LLJ 8, V) 28 LOT 119 LOT 118 LOT 117 A 151 m r LOT 0 1 lul Z' lot z w I co 0 ui 0 (x V) tf) I PUE 21 ®2' SHORT Ld SIDE SERVICE DWY Fn M C:) (0 ... ...... LOT 129 ................. . . ... ......... .......... ...... _d/ 51 61 . . . . . . . . . . . . . . ... .. ..... ............ . . . ........ ............ -L4T Ar ............... 10 F_-1 EN L2J 1 C-41 L J L _J_ 10 c icf LLI 10 / 1 5-1\ PST GSTC PUE I Lui LIN GPTC 15 / w �ij:\ 0 m "gl000, Ox 0 Li 61' Li Ld Li Ld 243' CAW U) In En cn (n (n V) En Lu ui W LOT 130 a -0 -0 W -" Li En cn En 4" ul LOT 131 LOT 132 LOT 133 LOT 134 >_ LOT 135 LOT 136 LOT 137 LOT 138 LOT 139 LOT 140 LOT 141 o O0 0o ao 00 o0 10' PUE STC LOT 142 62 LOT 96 ILOT 95 I LOT 94 ILOT 93 I LOT 92 ILOT 91 LOT 90 LOT 89 I LOT 88 ops LOT 87I 24c 24 's Ol m _j �Lj q LWL-1 I I q LMIJ I I ON] N] in I U) min I U) LOT 74 I LOT 75 I LOT 76 I LOT 77 I LOT 78 I LOT 79 I LOT 80 I LOT 81 I LOT 82 LOT 83 10' PUE LOT 73 LOT 72 LOT 71 LOT 70 LOT 69 LOT 68 LOT 67 LOT 656 LOT 65 LOT 64 LU LL1 0 L) Ld L9 L) L) Z5 Z!-> owl 0 of zw OW W z 0 u En -i _j W _j LU _j uJ cn (n W () to LLJ to C3 LLJ coW LLJ Ln too PUE ... ................. -------- ... ............ 77777�; -7� ............. 7 :4 LOT 84 ........... ........... .. .. ..... . I . ........ .... . ............... . ..... ............ . ......... ..... TWINK LLANE 0 .......... sf.) '-.0 .................... o .................... . ......... ............ ... ................ IT09�d. lot 5s LOT 86 LOT 85 DWY DWY 16' SHORT SIDE SERVICE 10' LOT 143 A_m LOT 144 LJW T L C) _c LOT 150I ILA.- L: ID OT 20, L bc 01 O C" ............... ..... 2' SHORT SIDE SERVICE DWY 07E ­ LOT 149 I z 0 Ln LOT 30 ­!&_ 4 .............. GPTC 24' >< > GPTC 40 Qc) i 00 2 SHORT U cd C" 01 SIDE SERVICE DWY ...... tw 0 LOT 148 OT PST LE— > 31 0-4 Z LO 124' E lot m PUE -- — --------------- C) CL .3 LOT 147I LOT 3 a Q 8' DWY J cm r"r' DWY I I Q E C`4 GPC00 LOT 33 CO 24' #01� 621 LOT 146 U> C-4 SERVICE GP CA L> cn 43 m Ln co . . . ........ . . .... .... ................ ' 5 OR TIE INTO CD CL. EXISTING JT b 11-1 a- C-) (:I C/) a- .............................. PCC ... ..... . .. .. ... \_L9 COOL RUSH TERRACE 27 -AP PL ;6 TIE SERVICE :INTO 1 4 EXISTING GAS. � I � L DWY L DWY 167_"__SHORT - — I — —:-) \ SIDE SERVI�CE 2 Lij LOT 145 SERVICE [L TIE INTO IV EXISTING LOT 63 LOT 62 LOT 61 # Oxzi Z!5 GAS _j uJ _j uJ cn (n 40' TIE SERVICES SERVICE INTO EXISTING GAS 14' 'EXISTING) .... . ........ PL GAS L G IP HP P AS2" H , ........ .... .... ..... . .......... ........ .. .......... GO, ............................ $s 6' 6 40-69f 9 90 SERVICE 40' +_0 .......... F T L J I Lji T I C141 L _ hLe LJ L__j 1 NI PST PST STCSTC QSTCFUTURE SERVICE U.1) I u L 60 44' 16' STC L) brIL, 255' GPTC L W 52' 64' U L, PUE 10 36' 0 jr - 5N x C51N 5; of 5: 00: 0 0 X 10' 05 0 x Ld LJ W cn Ln En V) cn CA Lov' LOT 52 LOT 53 u.' L 0 T 54 LOT 55 '='uj LOT 56 7w V, xw LOT 51 l'W LOT 5 ui LOT 59 1-, En I (n n 3'x5' 60' V) I TEL cn 'n Lu 6 Li o o 3t B. LOT 58 00, Li ca ca 1 ro SCALE: 1 "=50' SCALE NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL DRAWINGS FOR ELECTRIC FACILITY PLACEMENT, DETAILS, AND CLEARANCES. 50' 01 50' 10( 6 5 4 3 2 cr u- m 7 -7-7-t- C) INCH 0 E— Ez (n 4.n E— M C) u- 7 -7-7-t- C> INCH 0 TY EXISTNG 8" HP PL SQUEEZE LOCATION PGE TO SQUEEZE 8" PL MAIN PER GS&S A-93.1 INSTALL- (1) 8" PLASTIC BUTT FUSION TEE CODE: 02-0202 (3) 8" ELECTROFUSION COUPLING CODE: 02-1631 LOCATING WIRE PER GS&S A-90.2 3 EXIS?ING 8" HP PL A T U n SQUEEZE LOCATION APPLICANT TO: 2 INSTALL: (1) 8" X 6" PLASTIC REDUCER CODE: 02-0766 o (1) 6" X 4" PLASTIC REDUCER a I I CODE: 02-7992 (1) 4" X 2" PLASTIC REDUCER CODE: 03-3947 GASTIE-IN DETAIL "A" NO SCALE [) I EXISTING 8" HP PL EXISTING 8" HP PL T U SQUEEZE LOCATION n SQUEEZE LOCATION PGE TO SQUEEZE 8" PL MAIN PER GS&S A-93.1 APPLICANT TO: INSTALL: (1) 8" PLASTIC BUTT FUSION TEE CODE: 02-0202 4, INSTALL: (1) 8" X 6" PLASTIC REDUCER (3) 8" ELECTROFUSION COUPLING o CODE: 02-0766 CODE: 02-1631 0I I (1) 6" X 4" PLASTIC REDUCER U CODE: 02-7992 LOCATING WIRE PER GS&S A-90.2 13 A GAS TIE-IN DETAIL "B" NO SCALE ETS STATION PER G.S. & S. 0-10 FIN. GRD. LOOP LOCATIONG WIRE TRIM EXTENSION IN BOX PER A-90.2(AS REQUIRED) '_OCA?��NG WIRE GAS MAIN ETS DETAIL_ NO SCALE 5 LB. ANODE - CODE. 56-9145 NOTE: PGE TO: IF UNABLE TO MAINTAIN 24" FROM INSTALL- (1) 2"xt" ELECTROFUSION TAPPING TEE TOP OF TEE , TIE-IN WITH 4" x 1" CODE: 03-5610 BRANCHING SADDLE. 24" MIN. COVER FROM FINISH GRADE. LOCATING WIRE PER GS&S A-90.2 PROPOSED 1" HP PL EXISTING 2" HP PL GAS TIE-IN DETAIL "E" NO SCALE 4 PLACES V ---A-93.3 " " 1 CTS BLIND CPLG1 CTS BLIND CPLG CODE: 01-5608 � \ CODE: 01-5608 MINLL EXCESS FLOW VALVES 8"-12" SERVICE TEE, PER GSS (1) 1 CTS 3 -WAY BLIND END WYE PG 4 OF 6 CODE: 02-1547 J [I- Li., >(1) 1" SERIES 1100 EXCESS FLOW VALVE > CODE: 02-1706 o n w (CONNECTED LOAD 800 CFH) � T o0 (1) 2" x 1" BRANCHING SADDLE 0_ < CODE: 02-9792 0-M PROPOSED 2"HP PL TYPI CAL STUB SERVICE TIE-IN DETAIL NO SCALE PGE TO: SQUEEZE EXIST. 2" MAIN REMOVE: (1! 2" PLASTIC CAP a INSTALL: (1) 2" ELECTROFUSION CODE: 02-1635 z LOCATING WIRE PER GS&S A-90.2 I J IoI IaI I..J a GAS TIE-IN DETAIL "C 11 NO SCALE 2 PLACES PGE TO: SQUEEZE EXIST. 4" MAIN REMOVE: (1) 4" PLASTIC CAP INSTALL: (1' 4" ELECTROFUSION CODE: 02-1637 Z LOCATING WIRE PER GS&S A-90.2 I�I I0I 0 a_ I` I..J a GAS TIE-IN DETAIL "D" NO SCALE APPLICANT TO: INSTALL: (1) 2" PLASTIC ELBOW CODE: 02-9760 LOCATING WIRE PER GS&S A-90.2 PGE TO: SQUEEZE EXIST. 2" MAIN REMOVE: (1) 2" PLASTIC CAP INSTALL- (1) 2" ELECTROFUSION CODE: 02-1635 LOCATING WIRE PER GS&S A-90.2 NP: I I IJE= T I o91 I l_..d GAS TIE --IN DETAIL "F" NO SCALE 5 LB. ANODE TEST AT 100-110 PSI FOR MINIMUM OF 5 MIN Pressure Duration Initials CODE: 56-9145 C7 12" MIN. LOCATING WIRE �rJ WARNING TAPE 1 1" CTS BLIND CPLG () G.S.&S L-16 CODE: 01-5608 w Footage and Size INSTALL EXCESS FLOW VALVES 8"-12' SDR / Wall Thickness U Pipe Manufacture FROM SERVICE TEE, PER GSS --F- ❑ PE 2406/2708 ❑ Other PE: w / SDR / Wall Thickness A-93.3 PG 4 OF 6 Pipe Manufacture co U) GAS PIPELINE ❑ PE 2406/2708 ❑ Other PE: Foreman LAN ID: Date:-/-/ Ii List all plastic pipe by footage, size, manufacture and date manufactured per Gas Design Standard A-93.1 (1) 1" SERIES 800 EXCESS FLOW VALVE -` CODE: 02-0953 _ O (CONNECTED LOAD 400 CFH) `- U - U O U Ot Z UJ w (1) 2" x 1" BRANCHING SADDLE Z o CODE: 02-9792 / IL � 1 M E- Of �! ATTACH EFV. I.D. TAG TO PROPOSED 2" HP PL STUB END USING THE LOC. WIRE. TYPI CAL SINGLE STUB SERVICE TIE-IN DETAIL ►� D t`) NO SCALE 7 � 8 Plastic Pipe Data TEST AT 100-110 PSI FOR MINIMUM OF 5 MIN Pressure Duration Initials Date of Test C7 12" MIN. �rJ WARNING TAPE G.S.&S L-16 6" X 1000' ROLL Plastic Pipe Data Footage and Size / SDR / Wall Thickness Pipe Manufacture Date Manufactured --F- ❑ PE 2406/2708 ❑ Other PE: Footage and Size / SDR / Wall Thickness G Pipe Manufacture co Date Manufactured GAS PIPELINE ❑ PE 2406/2708 ❑ Other PE: Foreman LAN ID: Date:-/-/ Foreman Signature: List all plastic pipe by footage, size, manufacture and date manufactured per Gas Design Standard A-93.1 GASLI N FINISH GRADE E CAUTION TAPE 2 C7 12" MIN. �rJ WARNING TAPE G.S.&S L-16 6" X 1000' ROLL TERA TAPE CODE: 37-9947 WARNING TAPE INSTALATiON ZONE --F- 12' 12" MIN. G co GAS PIPELINE (� INSTALLATION TESTED OR INSPECTED AND NOTED ON DRAWING ALL CORROSION LEVELS SATISFACTORY PER PG&E GAS UTILITY STANDARD TD -41815 QUALIFIED EMPLOYEE DATE Corrosion mechanics signature is required when a CPA boundary is within the scope of the project ATTENTION FOREMAN PRIOR TO STARTING JOB, CONSULT AREA CORROSION MECHANIC FOR LOCATING WIRE INSTALLATION AND CATHODIC PRO- TECTION REQUIREMENTS CONTACT: SAM HENRY PHONE: 661 342-0855 NOTIFIED U.S.A. DATE: TICKET f BY: 9 1 10 , GAS NOTES: 1. DEVELOPER TO INSTALL ALL GAS PIPE. 2. DEVELOPER TO DO ALL TRENCHING, BACKFILLING AND COMPACTING. 3. REFER TO TRENCHING COMPOSITE DRAWING FOR PRECISE LOCATION OF TRENCH, TRENCHING DETAILS, SHADING AND OCCUPANCY. 4. GAS PIPE REQUIRES SAND SHADING IF NATIVE SOIL IS NOT ROCK -FREE. PG&E WILL INSPECT BACKFILL MATERIAL 5. GROUND TO BE WITHIN .2 FT OF FINISH GRADE PRIOR TO INSTALLATION OF GAS PIPE. 6. GAS REQUIRES AT LEAST 3' OF SEPARATION (1' UNDISTURBED SOIL) FROM PARALLEL RUNS OF WATER, SEWER, OR STORM DRAIN. 7. PRE -CONSTRUCTION MEETING REQUIRED AT LEAST 2 WEEKS PRIOR TO START OF INSTALLATION. 8. CONSULT WITH PG&E REPRESENTATIVE PRIOR TO INSTALLING CONDUIT FOR GAS PIPE. 9. CONTACT PG&E REPRESENTATIVE PRIOR TO MAKING ANY CHANGES FROM THIS DRAWING. 10. ALL EXCESS FLOW VALVES TO BE PLACED 8"-12" FROM GAS MAIN. 11. CALL U.S.A. AT LEAST 48 HRS PRIOR TO TRENCHING (DIAL 811) CONTRACTOR CONSTRUCTION REFERENCES 1. REFER TO GAS STANDARDS A-90, A-93 & A-93.1 FOR TYPICAL DIRECT BURIAL PLASTIC GAS MAIN AND SERVICE INSTALLATION. 2. REFER TO GAS STANDARDS A-90, A-90.3 & A-93.1 FOR TYPICAL PLASTIC GAS MAIN AND SERVICE INSERT CONSTRUCTION. 3. REFER TO GAS STANDARDS A-90.2, 0-12, 0-13, 0-13.1 FOR TYPICAL ANODE AND LOCATING WIRE INSTALLATION ON DIRECT BURIAL PLASTIC GAS MAIN AND SERVICES. 4. REFER TO GAS STANDARDS AND A-90 & A-91 FOR TYPICAL GAS SERVICE RISER INSTALLATION 5. REFER TO GAS STANDARD A-34 FOR TEST CRITERIA ON GAS MAIN AND SERVICES. 6. PACIFIC GAS AND ELECTRIC TO PERFORM ALL HOT TIE-INS AND PURGING OF GAS PIPING PER GAS STANDARD A-38 7. CONTRACTOR IS RESPONSIBLE FOR CROSSING EXISTING WATER, SEWER AND STORM DRAIN LINES, EITHER UNDER OR OVER, AS REQUIRED TO MEET P.G.&E. COVER AND CLEARANCE REQUIREMENTS. REFER TO UO STANDARD S5453. B. THE LOCATION OF ALL EXISTING OR NEWLY INSTALLED WATER, SEWER, AND STORM DRAIN CR OTHER LINES. SHALL BE DETERMINED BY THE CONTRACTOR. THE CONTRACTOR SHALL NOT RELY 014 PG&E TO LOCATE FACILITIES. (PG&E WILL LOCATE PG&E FACILITIES UPON PROPER USA NOTIFICATION). CALL USA AT 811. 9. THE CONTRACTOR WILL BE REQUIRED TO REMOVE AND REPLACE TRENCH SPOIL WITH SELECT BACKFILL AS REQUIRED BY PG&E SPECIFICATIONS, AND ANY LOCAL CITY, COUNTY OR STATE REQUIREMENTS. 10. THE CONTRACTOR WILL BE REQUIRED TO PLACE TEMPORARY AND/OR PERMANENT PAVING I'q ACCORDANCE WITH ANY LOCAL CITY, COUNTY OR STATE REQUIREMENTS. 11. USE #10 WIRE ON ALL MAINS AND SERVICES. 12. REFER TO GAS STANDARD J-15 FOR GAS METER LOCATIONS. APPLICANT TO VERIFY RIGHT OF WAY, THE CONTRACTOR SHALL OBTAIN ALL APPLICABLE PUBLIC UTILITY EASEMENT AND/OR PUBLIC SERVICE PERMITS PRIOR TO COMMENCING THE WORK EASEMENT ACQUISITION PRIOR TO CONSTRUCTION AT NO COST TO PG&E. LEGEND: - - - - - PROPOSED SERVICE PROPOSED MAIN LINE EXISTING GAS FACILITY PROPOSED 5 -LB ZINC ANODE ® PROPOSED 4' x 6' x 12" BELLHOLE (12" UNDER PIPE) E -;7'v PROPOSED EXCESS FLOW VALVE IE PROPOSED ETS BOX LOCATED IN OR BEHIND SIDEWALK Zd E�PANAMA LN SITE BERKSHIRE RD o Q- v, x o z En H05KING RD N McCUTCHEN RD VICINITY MAP NOTE: ALL SERVICES AND SUB -STRUCTURES ARE NOT TO SCALE FOR CLARITY. ALL COMPONENTS SHALL FIT WITHIN THE PUE OR FRANCHISE AREA UNLESS OTHERWISE NOTED. REFER TO DETAILS FOR LOCATIONS. NTS DESIGN CHANGE COMPONENT ANY CHANGES TO THIS DESIGN MUST BE APPROVED BY DOMINIC OTHART (661) 398-5817 PG&E GAS ADE RECAP 1. INSTALL 1,370' OF 4" HP PL MAIN 2. INSTALL 7,040' OF 2" HP PL MAIN 3. INSTALL (9) ETS STATIONS 4. INSTALL (11) 5# ZINC ANODES 5. INSTALL (174) 1# MAGNESIUM ANODES 6. INSTALL (95) 1" EFV VALVES (16) 800 SERIES (79) 1100 SERIES 7. INSTALL (174) 1" PL SERVICE STUBS (3,505') 8. INSTALL (173) 1" PL SERVICE COMPLETIONS (4,325') 9. TIE-IN (1) 8" PL X 4" PL (BY PGE) 10.T:E-IN (1) 8" PL X 2" PL (BY PGE) 11. TIE-IN (1) 4" PL X 4" PL (BY PGE) 12. TIE-INS (3) 2" PL X 2" PL (BY PGE) 13. TIE-INS (4) 2" PL X 1" PL SERVICE (BY PGE) PLAT 5126 A7 & B7 M.A.O.P. 60 PSIG C.P.R./C.P.S 512600 T.B.A. T-01 EMERGENCY ZONE: - w I-- V) O 11M1 � 11 O U O � z U Z CID w Of w L w Of o � O_ N U - W o: W 2 C7 �rJ co (� O -` O LZ `- C�6 U O U Ot Z O E v) a Z O a ri � 1 M E- =a -. E- U2�F�a v) n ►� D t`) x UD d' t71 ,a m Ems-+ . E- p1 N O E- W OJ o cn z a X101 U L0 o Z CZ)y C=) p U N 0 000c rn . rn ca W ti Cfl N ?� 4 _ Q cn urf Uri = O U t/) >._ ® p OZ ® rn Q1 LJ --- U U L'j Z C3 C3 -� � __J U w 2 c� a. Q U cn m M 0 Q o_ N 0 Y S U 3 0 w I-- V) O 11M1 � 11 O U O � z U Z CID w Of w L w Of o � O_ N U - W o: 6 5 4 3 2 1 INCH C �Is W C7 O -` C�6 O a LL's J t�J � M E- v) n Y �! m Ems-+ . O W o cn U LAJZ o a. 6 5 4 3 2 1 INCH C �Is D ■V � 2 3 4 8 1 10 II >I I III a I I II p a< , v `W,:�-+w.,,. ....,v. ,,,v,.. ,,,..., .mm. w.,v:. ,:,.,... �:. ,..v... ..w.,,. wae. v...... v,..,w-,w.,.. .,vv. ,�:...,. .vin _ ..-. - ri•.sx +�aeavsf s „gym ..- .i.•. .- -. ..... J " .,..,,, .,.w.,, w„„, ...,V.:. a,.,w m,.ry„ ,.„,.. +...w ..,,,,,, +v..,. ..,•:.., .ww, ...w,, v+..w- «-..,,, ,_,..w, ,,.,,.., ..o.., ..w..:: ww„, ,.+.,.wvv+..v,.v„ ....... ....... .•..... ,,,,.., ,,..,.,, ::......'...,„, .,-.,,,. w,w.w ,ww„: w,.w. ,F`�3 F£............... -... CL ao xto �o X DETAIL "B" INSTALL 4'x6' BERKSHIRE ROAD o BELLHOLE r— 11' (EXISTING) DETAIL "A” INSTALL 4'x6' BELLHOLE T•XISTIN "..,. u.....,. • U�661,�L1b �00'� w.:�w.. ,_.-,-..,_,...,.._., ,,."ww-,...:.......:.. »,w,,..... ..., ` EX 8 HPPL 'r1 �, — (MAOP 60#) PM: 30657326 ,.009 µ 100' 3<_ 9' FROM k_ i. P/ L a OF 4" HP PL MAIN CODE: 01-6081 3'-6" FROM V) W r` cr_ o W E° [Y C Q �I W >< O is W U cd PL MAINCL °D 46 CLLJ! L� Li, Vi DETAIL "A” INSTALL 4'x6' BELLHOLE T•XISTIN "..,. u.....,. • U�661,�L1b �00'� w.:�w.. ,_.-,-..,_,...,.._., ,,."ww-,...:.......:.. »,w,,..... ..., ` EX 8 HPPL 'r1 �, — (MAOP 60#) PM: 30657326 ,.009 µ 100' 3<_ 9' FROM k_ i. P/ L f INSTALL 605' OF 4" HP PL MAIN CODE: 01-6081 3'-6" FROM ROW L Lu r` cr_ o W QO 44s' LOT 165 C Q �I Z >< O is o ao U cd PL MAINCL °D 46 CLLJ! L� Li, Vi to cli ( Z INSTALL 280' i CD � Lo E-., ta. ) Q Y N — — OF 2" HP PL MAIN 10, X;: CODE: 01-6079 ' i ni C> i 10, T 1 O k iE z LL O ' 10' L 0 T 213 O C-)oo= PUE III I? 1 PUEtaw I 6n' I ( I k ............ t... _... mow... w.....w..:-„,.....w nn=n — o -., w , w_ w - - "..,,......,..w.w _,. �--.� i to DETAIL "A” INSTALL 4'x6' BELLHOLE T•XISTIN "..,. u.....,. • U�661,�L1b �00'� w.:�w.. ,_.-,-..,_,...,.._., ,,."ww-,...:.......:.. »,w,,..... ..., ` EX 8 HPPL 'r1 �, — (MAOP 60#) PM: 30657326 ,.009 µ 100' 3<_ 9' FROM k_ i. P/ L f INSTALL 605' OF 4" HP PL MAIN CODE: 01-6081 3'-6" FROM ROW L Lu r` cr_ o W INSTALL 44s' LOT 165 C Q �I Z >< O is 6' FROM ROW 9' FROM P/L (MAOP 60#) I INSTALL 180' E 1'AF I OF 2" HP PL MAIN I / I p 5 CODE: 01-6079 ETS I LOT 12 owl LOT 11 w LOT 10 LOT 9 LOT 8 LOT 7 LOT 6 LOT 5 LOT 3 LOT 1 L BERKSHIRE ROAD 0: IT t72 I nT 1-7n i `, i w Z ��1 I �I I wl I wl I LOT 4 wi I LOT 2 w I a= I LOT 169 , Z w Z� w LOT 171 w LOT 170 � 0 0 z5 ZS z5 Z5; 5; oI? I v I I I V I Z o \ N JAI owl I pwl I o�1 I ZwI i zs z5 � I°mss Q' Vw ,vwi Jcwi, �vwi �V)il 10' i� CL 60 I 10 jLd I oLd mo aw :r (n t� h� rnN (0o (oo coo PUE , PUE �o 5# ZA �° 1 N 10' `� (NEW) 10'�- LOT 168 ■ PUE ' , N F— PUE , II `•.,,w,.w: . I , - I -—_. kk L S...:: t .... .. .. 1100 ...... EF LO. 2. .:, I z , _ , I Jj ci . I I g 00 oen Icno 00 t k ! I 6 (NEW) CRYSTAL CASCADE LANE1 o I I - - o ..... _... , , ara �. ...... c r .................... .. �r, . �. .. € .,.. C" W x i ........_J�FV ..... t .... CO CC C7 1. �_. ..... LOT 167 - - - I -w - 1 Q _ 500 EFV: i �S , ✓ '"' r_ 1100 EFV I i 1100 NEW' ' �.: `; • ,: � ... } . Vic; I I 1100 EFV _ 1100 EFV 1100 EFV 1 6':> :(NEW) 1100 FV ca a G,- $ 800 EFV w__„ Mw. _ , .. ht3 S�,•Fw w""... - 100 EFV E c� ...w ., � t F 1.100 EF�i'a. c.ri m800 EFV,CD SF ORT I 1 Z rn I E 10' 84Q .EF w,w 10 U W y o E�$ �� -cwi �v PUE cwi �cwi� w w Z -� � J^ 5 �� �5 �S Ips �s �c� c� PUE o \ U O QE d Q ZA o� o�\ o�� o�� o� o 1 k D i w N to N N N N I Vm: ui=I N to N N (n e Q / V=1 uwi S �.' >..„,...,..,.,w.ww. V d W [� Q trl 1 mol Imo I I -"o I I Imo I Imo I O I�w IOW � LOT 166 cn V)I�'co 1 En LOT 13 mol LOT 14 LOT 15 I LOT 16 LOT 17 LOT 18 I LOT 19 LOT 20 I LOT 21 I LOT 22 I LOT I Y I�� 1 I N��s�� I -.µ ` �" 23 LO 24 I I LOT 162 LOT 163 LOT 164 I INSTALL 687' OF 2” HP PL MAIN CODE: 01-6079 i I I I LOT 35 LOT 34 LOT 33 LOT 32 LOT 31 LOT 3 O I;I w i `, i w Z Lo Q E— INSTALL 44s' LOT 165 C Q >< O i' o ao U cd PL MAINCL °D 46 CLLJ! L� Li, Vi to cli ( Z INSTALL 280' i z � Lo E-., ta. ) Q Y — — OF 2" HP PL MAIN 10, X;: CODE: 01-6079 ' i — — — — — — — — — —� 10, T 1 O ��1 I �I I wl I wl I LOT 4 wi I LOT 2 w I a= I LOT 169 , Z w Z� w LOT 171 w LOT 170 � 0 0 z5 ZS z5 Z5; 5; oI? I v I I I V I Z o \ N JAI owl I pwl I o�1 I ZwI i zs z5 � I°mss Q' Vw ,vwi Jcwi, �vwi �V)il 10' i� CL 60 I 10 jLd I oLd mo aw :r (n t� h� rnN (0o (oo coo PUE , PUE �o 5# ZA �° 1 N 10' `� (NEW) 10'�- LOT 168 ■ PUE ' , N F— PUE , II `•.,,w,.w: . I , - I -—_. kk L S...:: t .... .. .. 1100 ...... EF LO. 2. .:, I z , _ , I Jj ci . I I g 00 oen Icno 00 t k ! I 6 (NEW) CRYSTAL CASCADE LANE1 o I I - - o ..... _... , , ara �. ...... c r .................... .. �r, . �. .. € .,.. C" W x i ........_J�FV ..... t .... CO CC C7 1. �_. ..... LOT 167 - - - I -w - 1 Q _ 500 EFV: i �S , ✓ '"' r_ 1100 EFV I i 1100 NEW' ' �.: `; • ,: � ... } . Vic; I I 1100 EFV _ 1100 EFV 1100 EFV 1 6':> :(NEW) 1100 FV ca a G,- $ 800 EFV w__„ Mw. _ , .. ht3 S�,•Fw w""... - 100 EFV E c� ...w ., � t F 1.100 EF�i'a. c.ri m800 EFV,CD SF ORT I 1 Z rn I E 10' 84Q .EF w,w 10 U W y o E�$ �� -cwi �v PUE cwi �cwi� w w Z -� � J^ 5 �� �5 �S Ips �s �c� c� PUE o \ U O QE d Q ZA o� o�\ o�� o�� o� o 1 k D i w N to N N N N I Vm: ui=I N to N N (n e Q / V=1 uwi S �.' >..„,...,..,.,w.ww. V d W [� Q trl 1 mol Imo I I -"o I I Imo I Imo I O I�w IOW � LOT 166 cn V)I�'co 1 En LOT 13 mol LOT 14 LOT 15 I LOT 16 LOT 17 LOT 18 I LOT 19 LOT 20 I LOT 21 I LOT 22 I LOT I Y I�� 1 I N��s�� I -.µ ` �" 23 LO 24 I I LOT 162 LOT 163 LOT 164 I INSTALL 687' OF 2” HP PL MAIN CODE: 01-6079 i I I I LOT 35 LOT 34 LOT 33 LOT 32 LOT 31 LOT 3 O I;I w i `, i w z 0 Q LOT 161 INSTALL 44s' LOT 165 C Q tr 0 i ? k OF 2' HF CODE: 01--6079 PL MAINCL 46 CLLJ! L� Li, Vi 1 ( Z INSTALL 280' 1 INCH 0 � Y t1i Q Y — — OF 2" HP PL MAIN 10, X;: CODE: 01-6079 ' i — — — — — — — — — —� O z O ' 10' L 0 T 213 O (li PUE III I? 1 PUEtaw I 6n' I ( I o 0 LOT 29 LOT 28 LOT 27 LOT 26 LOT 25 _ LOT 60 LOT 159 LOT 158 LOT 157 �, LOT 156 LOT 155 � v I U w w w w 5 INSTALL 73' 'ash Z 5 0 5 1 1 �, S I I 0 I I 01 w Z 1 I OF 2" HP PL MAIN �;`�n� 1 �vwil owI I _jwI oW ow I 6' I oxi a) of I �w A, 04V — — LLIo S L..._.....w:.. ,� CODE: 01-6079 d w (NEW -'N -'moi L' r q- INSTALL 74' cow 00 vw aw aw � a \ . ) I g q � moi!' in mo tOp 0o rao_ ? �w1 �w OF 2" HP PL MAIN rn / \ in 10' N I 1 �' 10' 5# ZA '51 CODE: 01-6079 / I LOT ; PUE PUE _ %� -... z E J i .... :: .......- : ......; r m" � C) LOT36 wwww 11`00 EFV ! s . w,w �. 5# ZAf I :: I : I -- tr.FF,,� a / OT 154 - f _ ,,..... f �, 110 L , - _; :: W :.. LARI DN CH :: �I s.. ANN �u....:..._.. C. ., co A ZA 6 NEW T � 800 EF , � ,:.,. ' �^ - ::. .------ .. W € s 6 NEW 25 1100 EFV 110q FV ( ) 1100 EFV :1100 EFV:: SDE NORT 1100, EFV, ww _ 1.1,OQ.IRFV 11 0 FV 800 EFV .1100 EFV .I ! sE , '� ,� , E ...... . 1100 EFV.__ 800 EFV ��-` 11_DO EFV 1 t [ FV E 1110 EFV : E" — -do LOT 37 I ^� I v; / ETS \ i BOE) IEFV +< w w I 11 LOT 38 I . INSTALL 142' OF 2" HP PL MAIN CODE: 01-6079 16' SHORT SIDE SERVICE LOT 39 10 PUE w w ..I ( w w tnV) En En 00 (nN xw iw =w �r I LOT 103 ��o LOT 104 ( LOT 105 ��w LOT 106 I LOT 107 �w LOT 108 LOT 109 LOT 110 LOT 111 N�' LOT 113 �� LOT 114 LOT 115 �'�' LOT 116 Li - �� I�� I I�� I Imo I Imo -,� > t I i I I 1Ln � 1100 i INSTALL 386' i LOT 112 (I INSTALL 648' OF 2" HP PL MAIN € y IR- `I I OF 2" HP PL MAIN CODE: 01-6079 6, �CODE: 01-6079 NEW)1QJ 8 , I '._. 10 ' I _ESV PUE (NEW) — — — fi0'.....Piz t I LOT 102 LOT 128 LOT 127 LOT 126 LOT 125 LOT 124 LOT 123 LOT 122 LOT 121 LOT 120 LOT 119 LOT 118 ' ' J i 60 :. x- s. MATCH LINE A -A (SEE SHEET 3) MATCH LINE A -A (,SEE SHEET 3) i NOTE: ALL SERVICES AND SUB—STRUCTURES ARE NOT TO SCALE FOR CLARITY. ALL COMPONENTS SHALL FIT WITHIN THE PUE OR FRANCHISE AREA UNLESS OTHERWISE NOTED. REFER TO DETAILS FOR LOCATIONS. PLAT 5126 A7 & B7 M.A.O.P. 60 PSIG C.P.A./C.P.S 512600 T.B.A. T-01 EMERGENCY ZONE: — NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTF CAL DRAWINGS FOR ELECTRIC. FACILITY PLACEMENT, DETAILS, AND CLEARANCES. SNO VICE SIpE SER LOT 153 LOT 2 I, INSTALL 141' OF 2" HP PL MAIN SHORT CODE: 01-6079 SIDE SERVICE I LOT 152 1 LOT 27 LOT 151 N1 SCALE: 1 "=50' SCALE 50' 0' 50' 100' 6 5 4 3 Ld I— V5 O O_ �o U o � z_ U r 1 z V W �► o 0_ Ld LL_ w 2 G w z 0 W z C Q tr 0 46 CLLJ! L� Li, 1 c= 1 INCH 0 � Y t1i O O (li z -- W Z 0 tL 0 1 INCH 0 ID CI., 13 W, 9' FROM P/L INSTALL 126' N LL 1 2 ST� HIP OF 4" HIP PL MAIN CODE: 01-6081 6' FROM ROW 90' INSTALL 639' '.- OF 4' HIP PL MAIN CODE: 01-6081 5# ZA m A 9' FROM P/L 2111111�1 L_ 11=02 DETAIL "D INSTALL 4'x6' BELLHOLE AL 81, LOT 39 10, PUE "N4 16' SHORT LOT 40 SIDE SERV IC INSTALL 129' OF 2" HP PL MAIN CODE: 01-6 079 0 PUE 3 1 4 8 9 MATCH LINE A -A .(SEE SHEET 2) MATCH LINE A -A (SEE SHEET 2) 8' 7t LOT 102 7. LOT 127 LOT 126 LOT 125 LOT 124 LOT 123 1 C)T 199 1 OT 1'71 1 OT 1 0f) I r%T LOT 128 k I E7W 10 PM W 119 L 1 110 LOT II/ k 8 U. Lu LOT LOT 2'%� 151 z owl Z 3 10' Q0 -1100 EFV: oo::l oaf I oxl 0 X _j _j LJ _j LJ 60' __j W U) U)co LO Lu V) PUE Lu Lu LONG �? 0 FV CO 0 (00 Lj 71j'v - "<SHORT 00 W3 00 E In rV] SIDE SERVICE Lo LA_ DE SERVICE to 0 to a 1100 E In m it 5 ZA 10, 61�r LOT 101 UE UTS . ...... ..... LOT 150 LL: L LP CD !D INSTALL I 'C p 4" OT 29 41 INSTALL 126' Hp OF 2" HP PL MAIN OF 2" H PL MAI 1ST L N, a. 0 . 01 . : , : i � = - 7 ----- - ---- - - --- . ..... .. i -6079 7- 7.7 �7� 17 ........ .... 0- DE 6079) .......... CODE: 01 -6079 CODE: 01 ct 1100 &V�'\ C4 0 RIVULET RU --------- - N COURT (0 ........... ........... 800 FFa; 2' SHORT o 2' SHORT 0 LOT 129 ....... .........fc c 7 C14 .......... SIDE SERVICE 1:100 E Z V 51 1100 EF 1100 EFV v _FV C NEW 1100 EFV 1100 EFV Z) A V . ....... . ..... .. 1100 EF ETS (NEW) _j LOT 100 X 11 OP �EFV . .. ............ ... 8 -L77 '77' co 1Po EFV . ................. . LOT 30 E— ROUS LANE LOT LUST 149 r- .. . . ....... 10' - - ----------- - ---------- 64' LONG LA ......... .. ......... \&\W 1100 EFV ."._- C) LLI 50 L) 'r w 00 EFS SHORT c" PUE SIDE SERVICE 0 w ow 0 m = Ld CA En En In LLI 800 05 cn In V) U) SIDE SERVICE fO Lj b.0 0 -W W 1 1. En .. ........... 1-. LLJ Lu LOT 130 E-1 LOT 411 - V) En In .......... LOT 99 Q) LOT crs Ln V LOT 148 IN LOT 131 LOT 132 LOT 133 LOT 134 LOT 135 LOT 136 E— INSTALL 231' AIN a 7 141 OF 2" HIP PL MAIN LOT 13 LOT 138 LOT 139 LOT 140 LOT CO 10, 1 INSTALL 7913' 10, CODE: 01-6079 10, m <� PUE 10, ----------- OF 2" HIP PL MAIN PUE PUE ------------- CODE: 01-6079 E ------------ V) 16' SHORT 1;100&V [co SIDE SERVICE cf) 0 - LOT 147 will LOT 42 60' L 0 3 8 (NEW) LZ) INSTALL 293' OT 142 LOT 98 LOT 97 LOT 96 LOT 95 LOT 94 LOT 93 LOT 92 LOT 91 LOT 90 LOT 89 LOT 88 LOT 87 4"'SHORT OF 2' HP PL MAIN Q '' CODE: 01-6079 Lu (NEW) L) V SIDE SERVICE 0 1 100 E"V Z Z!-> .............. z 0 0 w_ owl Z 5; 0 w_ Owl _j La II I_j LU E .......... En cn En V) JW LU ETS iloo 5FV: Lu -x c=> ci UJ v41 to CO ED LOT 33 > ORT 78' SHORT 00 LLJ 10' in- / LOT 43 _.j Ckt 10. SIDE SER PUE E # V LOT 143 $0, PUE US LOT 146 4:114 C_.) m ........... . -n-1 ------- LO 80� C= E ....... ... . . . ..... C> A 77 ...... .............. V"L 5# ZA 1100 EF loop -&v" in DETAIL 1TSHORT lfl 00 EFV j A SIDE SER --- ------- A LOT 86 INSTA LL 4'x 6' LLJ LLJ 0 5p c_.) CD, co BLACK PEARL COURT I I BELLHOLE _---------------- <� . . .. ............. M LOT 44 A— . ....... ...... . I 33 INSTALL 280' =I OF 2* HP PL MAIN CODE: 01-6079 .. ...... . j> .. ........ n INSTALL 65' OF 2" HP PL MAIN II CODE: 01-6079 'N E HE_P"A�b 6# o 0 1-- (EXISTING) C14 0 0 CS1 -j a.tn N a - to N LOOKING GLASS �0 !� 0 " LO LANE C.4 a - CL 80 6f (EXISTING) (EXISTING) lk- ............ .. ........ . . .... ... . --- ....................... EFV1100 EFV 1100 EF 1'WO E -V 6 (NEW) 5# Zk 1100Q cn 1100 EFV .. ...... ... ___ _V �J!Q J.' -9 E 1100 EFV 1100 EFV 1100 � NE 6' (NEW) 7 V, LOT 74 LOT 75 . ...... ...............N r -W) LOT 144 COOL RUSH TERRACE 1100 EF*_'. . . 10' ........ — II 2 J EX."�-HPPL-4' euT)­ (MA-OP 60#) PUE ' / W - lw�wj'\ 4 x 0 n n Nn Lu Ow Nn ,o n LOT 85 V) I_ 110 EFV N v, In LLJ LOT 84 PQ cn 74' LONG SIDE SERVI�� C:)=> li LAJ LOT 80 LOT 81 LOT 8 2 LOT 83 � ce _J a - E, DETAIL "E" ce- V) M :< W 119 L 1 110 LOT II/ k 8 U. Lu LOT LOT 2'%� 151 z owl Z 3 10' Q0 -1100 EFV: oo::l oaf I oxl 0 X _j _j LJ _j LJ 60' __j W U) U)co LO Lu V) PUE Lu Lu LONG �? 0 FV CO 0 (00 Lj 71j'v - "<SHORT 00 W3 00 E In rV] SIDE SERVICE Lo LA_ DE SERVICE to 0 to a 1100 E In m it 5 ZA 10, 61�r LOT 101 UE UTS . ...... ..... LOT 150 LL: L LP CD !D INSTALL I 'C p 4" OT 29 41 INSTALL 126' Hp OF 2" HP PL MAIN OF 2" H PL MAI 1ST L N, a. 0 . 01 . : , : i � = - 7 ----- - ---- - - --- . ..... .. i -6079 7- 7.7 �7� 17 ........ .... 0- DE 6079) .......... CODE: 01 -6079 CODE: 01 ct 1100 &V�'\ C4 0 RIVULET RU --------- - N COURT (0 ........... ........... 800 FFa; 2' SHORT o 2' SHORT 0 LOT 129 ....... .........fc c 7 C14 .......... SIDE SERVICE 1:100 E Z V 51 1100 EF 1100 EFV v _FV C NEW 1100 EFV 1100 EFV Z) A V . ....... . ..... .. 1100 EF ETS (NEW) _j LOT 100 X 11 OP �EFV . .. ............ ... 8 -L77 '77' co 1Po EFV . ................. . LOT 30 E— ROUS LANE LOT LUST 149 r- .. . . ....... 10' - - ----------- - ---------- 64' LONG LA ......... .. ......... \&\W 1100 EFV ."._- C) LLI 50 L) 'r w 00 EFS SHORT c" PUE SIDE SERVICE 0 w ow 0 m = Ld CA En En In LLI 800 05 cn In V) U) SIDE SERVICE fO Lj b.0 0 -W W 1 1. En .. ........... 1-. LLJ Lu LOT 130 E-1 LOT 411 - V) En In .......... LOT 99 Q) LOT crs Ln V LOT 148 IN LOT 131 LOT 132 LOT 133 LOT 134 LOT 135 LOT 136 E— INSTALL 231' AIN a 7 141 OF 2" HIP PL MAIN LOT 13 LOT 138 LOT 139 LOT 140 LOT CO 10, 1 INSTALL 7913' 10, CODE: 01-6079 10, m <� PUE 10, ----------- OF 2" HIP PL MAIN PUE PUE ------------- CODE: 01-6079 E ------------ V) 16' SHORT 1;100&V [co SIDE SERVICE cf) 0 - LOT 147 will LOT 42 60' L 0 3 8 (NEW) LZ) INSTALL 293' OT 142 LOT 98 LOT 97 LOT 96 LOT 95 LOT 94 LOT 93 LOT 92 LOT 91 LOT 90 LOT 89 LOT 88 LOT 87 4"'SHORT OF 2' HP PL MAIN Q '' CODE: 01-6079 Lu (NEW) L) V SIDE SERVICE 0 1 100 E"V Z Z!-> .............. z 0 0 w_ owl Z 5; 0 w_ Owl _j La II I_j LU E .......... En cn En V) JW LU ETS iloo 5FV: Lu -x c=> ci UJ v41 to CO ED LOT 33 > ORT 78' SHORT 00 LLJ 10' in- / LOT 43 _.j Ckt 10. SIDE SER PUE E # V LOT 143 $0, PUE US LOT 146 4:114 C_.) m ........... . -n-1 ------- LO 80� C= E ....... ... . . . ..... C> A 77 ...... .............. V"L 5# ZA 1100 EF loop -&v" in DETAIL 1TSHORT lfl 00 EFV j A SIDE SER --- ------- A LOT 86 INSTA LL 4'x 6' LLJ LLJ 0 5p c_.) CD, co BLACK PEARL COURT I I BELLHOLE _---------------- <� . . .. ............. M LOT 44 A— . ....... ...... . I 33 INSTALL 280' =I OF 2* HP PL MAIN CODE: 01-6079 .. ...... . j> .. ........ n INSTALL 65' OF 2" HP PL MAIN II CODE: 01-6079 'N E HE_P"A�b 6# o 0 1-- (EXISTING) C14 0 0 CS1 -j a.tn N a - to N LOOKING GLASS �0 !� 0 " LO LANE C.4 a - CL 80 6f (EXISTING) (EXISTING) lk- ............ .. ........ . . .... ... . --- ....................... EFV1100 EFV 1100 EF 1'WO E -V 6 (NEW) 5# Zk 1100Q cn 1100 EFV .. ...... ... ___ _V �J!Q J.' -9 E 1100 EFV 1100 EFV 1100 � NE 6' (NEW) 7 V, LOT 74 LOT 75 . ...... ...............N r -W) LOT 144 COOL RUSH TERRACE 1100 EF*_'. . . 10' ........ — II 2 J EX."�-HPPL-4' euT)­ (MA-OP 60#) PUE ' / W - lw�wj'\ 4 x 0 n n Nn Lu Ow Nn ,o n LOT 85 110 EFV N v, In In V) I LOT 84 PQ cn 74' LONG SIDE SERVI�� C:)=> li LOT 76 LOT 77 LOT 78 LOT 79 LOT 80 LOT 81 LOT 8 2 LOT 83 � ce _J a - E, DETAIL "E" ce- E- M :< Im L C:) o cn LL_ INSTALL 4'x6' INSTALL 825' LOT 145 4 BELLHOLE ---------- OF 2"HIP PL MAIN CODE: 01-6079 .................. ................................. 1 o PUE I N CL a. 10' t PUE Ld LOT 60 5' (EXISTING). LOT 73 LOT 72 LOT 71 LOT 70 LOT 69 LOT 68 LOT 67 LOT 66 LOT 65 LOT 64 LOT 63 LOT 62 LOT 61 DETAIL "F" 05; 00 0 0 0 W uj 01 1 1 1 1 1 1 1 w I INSTALL 40' 5; 5 0 r. INSTALL 4'x6' Owl Oaf ZW zml z zwl 0 _j uj _j LLI 0 0 xi zu r- OF 2- HIP PL MAIN Zn Ll Ld 0 LLJ 0 Lu V) _j U) _j In _j LLJ BELLHOLE DETAIL "E" V) _j 'I CODE: 01-6079 -mow 'q- V) _j En co W tom 1W Li to uj W fn 0 to INSTALL 4-'x6' 10' �V' BELLHOLE L PUE 14' (EXISTING) m -------- ----- 7777�� 777� �7 .. . .......... 0 . ..... . ...... ....... 77777777r7���= 777�f -w_ ........ .. . .... ... ........... ---------- 2 (MAOP 60#) 0 PFU14(JT) TWINKLE LANE i wi . .... ....... ........... -- -- ------- - - ------- .... ......... ---- ------ 46 T - ----- - ---- -- ... b -------------- 5# ZA 'c' EFV .......... . ..... .............. Z '-�800 ............. 800 EFV. S 13 Q ..... ... ... z .......... EW . .. ... ...... .................. 6" (N 00 EFV 1100 EFV 1100 EFV 1100 EFV 1100: EFVj 6 :NEW ) 1100 EFV -61p :..,...,..:.<.,.. ....... . . 1100 EFV 00 W04 �FV 1�9 : 1 1: 1 �9, ffV 41 . ......... . ....... .......... .... 4'- 6 v mrrL 0 . ... . ........ . ....... 'k .......... E or\ 10 FUTURE SER ICE 10, ETS IV PUE Lou IPUE L) ow 15 mw 0 m: I LN 6 w �3 5;\ Lj 0 ox 5x ox Z: W A-1 LOT 45 Ax _j W En tn In _j V) 'u"'Wn LOT 46 LOT 47 -',n Lvi' LOT 48 LOT 49 1-, I'j LOT 51 lzm:wo LOT 52 LOT 53 'nv.' LOT 54 LOT 55 LOT 56 -to 1'�j I i VWXI W LOT 57 LOT 59 V) 6 i V) 0' u) a no In 2 V) V) INSTALL 472' I 1 61 DETAIL "C" OF 2m HP PL MAIN LOT 50 INSTALL 470' CODE: 01-6079 (NEW) OF 2" HP PL MAIN INSTALL 4'x6' CODE: 01-6079 LOT 58 BELLHOLE INSTALL 116' DETAIL "C" OF 2"HP PL MAIN 6' ' CODE: 01-6079 INSTALL 4'x6 NOTE: ALL SERVICES AND SUB -STRUCTURES ARE NOT TO SCALE FOR CLARITY. ALL COMPONENTS SHALL FIT WITHIN THE PUE OR FRANCHISE AREA UNLESS OTHERWISE NOTED. REFER TO DETAILS FOR LOCATIONS. I (EXISTING) INU) BELLHOLE N >- 3 PLAT 5126 A7 & B7 o _j M.A.O.p. 60 PSIC IL Cq _to C.P.A./C.p.S 512600 of T.B.A. T-01 Q) EMERGENCY ZONE: - cz 00 SCALE: 1 "=50' SCALE NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL DRAWINGS FOR ELECTRIC FACILITY PLACEMENT, DETAILS, AND CLEARANCES. 50' 01 50' 100, 6 5 4 3 2 O INCH 0 ck: C\2 PQ cn :2f C:)=> li M CO � ce _J a - E, to Jn fa� ce- E- M :< Im L C:) o cn LL_ O INCH 0 LEGEND INSTALL USE 2.5 -GAL DESCRIPTION P1 F11 EST. PULL 184LBS. PRIMARY CABLE - 1-1/OAL EPR ENCAP IN NEW 1-2" CONDUIT -P8 -P8 ACTUAL PULL ............ PRIMARY CABLE - 3-1100AL EPR ENCAP IN NEW 1-6" CONDUIT ---P9-P9 FOREMAN'S INITIALS PRIMARY CABLE - 3-1100AL EPR ENCAP IN EXISTINd_14E)Z-&DUIT S1 S1 13 LOC 18 SECONDARY CABLE - 4/OAL TPX IN NEW 1-3" CONDUIT S2 S2 USE 2.5 -GAL SECONDARY CABLE - 350AL TPX IN NEW 1-4" CONDUIT SV SV EST. PULL 169LBS. SERVICE CABLE - 4/OAL TPX IN 3" CONDUIT SV1 -SV1 ACTUAL PULL ............ SERVICE CABLE - 1/OAL TPX IN 3" CONDUIT LOC 'I TO LOC FOREMAN'S INITIALS STREETLIGHT CABLE EXISTING 26 LOC 27 DESCRIPTION 42 3 PHASE PRIMARY CABLE/CONDUCTOR - SIZE AS SHOWN INSTALL EXISTING DESCRIPTION r-2� 0 17" x 30" x 18" SECONDARY BOX [2E' 2E 17" x 30" x 26" SECONDARY BOX L3J 03 24" x 36" x 18" SECONDARY BOX 3E, 3E] 24" x 36" x 26" SECONDARY BOX L5- 05 3' x 5' x 3'6" PRIMARY ENCLOSURE 6, L -J © 4' x 6'6" x 5' PRIMARY ENCLOSURE -GAL 07 4'6" x 8'6" x 6' PRIMARY ENCLOSURE PKS. EST. PULL PMHI PADMOUNT SWITCH / INTERRUPTER ® ® PM TRANSFORMER, DF -LB, SIZE AS SHOWN tRar ............ LBS. FOREMAN'S LS2A STREET LIGHT, 70W, 50 KVA 6 CI ST 3 WAY 3 WAY SWITCH OLOC 65 TO LOC M OCD LOC 1 TO LOC 43 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 184LBS. & 2- FRONT END ACTUAL PULL ............ LBS. 149LBS. FOREMAN'S INITIALS .......... -GAL & 2- FRONT END PKS. 13 LOC 18 TO LOC 42 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 169LBS. 159LBS. ACTUAL PULL ............ LBS. LOC 'I TO LOC FOREMAN'S INITIALS .......... USE 2.5 26 LOC 27 TO LOC 42 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 93LBS. 100KVA 13 CUST ACTUAL PULL ............ LBS. ............ FOREMAN'S INITIALS.......... 120/240V 32 LOC 35 TO LOC 37 USE 2.5 -GAL USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 149LBS. FOREMAN'S INITIALS.......... -GAL & 2- FRONT END PKS. ACTUAL PULL ............. LBS. USE 2.5 -GAL FOREMAN'S INITIALS.......... 159LBS. ACTUAL PULL ............ O LOC 'I TO LOC 42 1 W/28 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 175LBS. T-763805 100KVA 13 CUST ACTUAL PULL ............ LBS. 120/240V FOREMAN'S INITIALS.......... 65 T-37058 100KVA 41 LOC 65 TO LOC 43 120/240V USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 272LEIS. 1 W/26 99 21 KV ACTUAL PULL ............ LBS. FOREMAN'S INITIALS.......... 50 KVA 6 CI ST 1 W/2B OLOC 65 TO LOC 42 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 20OLBS. 21 KV 120/240V ACTUAL PULL ............ LBS. 93 FOREMAN'S INITIALS.......... 13 CUST 1 W/2B 95 CABLE PULLING DATA 45 LOC 49 TO LOC 43 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 166LBS. LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS.......... -GAL & 2- FRONT END PKS. 52 LOC 49 TO LOC 157 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 159LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS.......... 1 W/28 63 LOC 43 TO LOC 69 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 190LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS.......... 71 LOC 76 TO LOC 65 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 169LBS. ACTUAL PULL............ LBS. FOREMAN'S INITIALS .......... 81 LOC 130 TO LOC 157 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 107LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS.......... 89 LOC 93 TO LOC 87 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 99LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS.......... 90 LOC 86 TO LOC 157 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 109LBS. ACTUAL PULL ............ LBS, FOREMAN'S INITIALS .......... ENVIRONMENTAL ISSUES ❑ NONE APPARENT (IF PROJECT DESIGN CHANGES, CONTACT ADE) ❑ BASED ON APPLICANT/DEVELOPER-SUPPLIED PLANS ❑ PERMITS ❑ TAILBOARD ❑ OTHER ❑ APPLICANT' DESIGN/RESPONSIBILITY (CHECK PERMITS BOX IF PERMIT CONDITIONS APPLY TO PG&E ACTIONS.) SIGNATURE GENERAL_ DESIGN INFORMATION: 102 LOC 69 TO LOC 155 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 256LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS .......... 107 LOC 111 TO LOC 155 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 93LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS.......... 115 LOC 111 TO LOC 119 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 149LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS .......... 141 LOC 137 TO LOC 143 CITY OWNED STREET LIGHTS - LS2A -GAL & 2- FRONT END PKS. EST. PULL LARGEST HOME = 2969 ACTUAL PULL ............ LBS. FOREMAN'S AVG HOUSE SIZE BASED ON 2368 SQ FT HOME 146 LOC 143 TO LOC 149 200 AMP MAIN PANELS EST. PULL 134LBS. SCI 10,000 AT ALL PANELS FOREMAN'S INITIALS .......... 5 TON A/C UNITS (170 LRA) 21 KV I 120/240V 102 LOC 69 TO LOC 155 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 256LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS .......... 107 LOC 111 TO LOC 155 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 93LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS.......... 115 LOC 111 TO LOC 119 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 149LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS .......... 141 LOC 137 TO LOC 143 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 101 LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS .......... 146 LOC 143 TO LOC 149 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 134LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS .......... 154 LOC 149 TO LOC 155 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 213LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS .......... 156 LOC 57 TO LOC 157 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 39LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS .......... Underground Service Alert Call: Toll Free 811 CALL TWO WORKING DAYS BEFORE YOU DIG PG&E GAS CONFLICT IDENTIFIED FOR THIS PROJECT GAS PLAT: 5126-A7 PG&E GAS FACILITIES IN PROXIMITY WITH EXCAVATION AT ALL LOCATIONS ON BERKSHIRE ROAD REVISION BY Electric Design by: L�*P E 5 UTILITY DESIGN SERVICES N. Office (559) 641 2954 46325 Wallu Lane Cell (559) 760 9464 Ahwahnee, California 93601 ELECTRIC CONSTRUCTION SKETCH S/E OF BERKSHIRE & MOUNTAIN RIDGE TRACT 6557-2 03NMIEWO CALIFORNIAI w800 -227 - THIS JOB WILL BE FULL APPLICANT CONSTRUCTION. APPLICANT TO TRENCH, BACKFILL, INSTALL ALL SUBSTRUCTURE AND DISTRIBUTION. PGBc- TO PERFORM TIE IN WORK AND INSTALL SERVICE CABLE. THIS SKETCH IS INTENDED FOR ELECTRIC CONSTRUCTION ONLY. PLEASE SEE JOINT TRENCH COMPOSITE FOR TRENCHING DETAILS. THESE DRAWINGS ARE CONSIDERED PRELIMINARY AND AT RISK, UNLESS STAMPED AND APPROVED BY PG&E AND P.E. ALL RES SERVICES ARE INVENTORIED A_t LOC SEE JOB INSTRUCTIONS FOR CONDUIT IN FRANCHISE AND PRIVATE PROPERTY. 158 PG&E TO INSTALL SERVICE WIRE XX'/XX'/XX' ALL SHORT SIDE SERVICE ARE 25'/39' �s \ o v UNLESS OTHERWISE NOTED CJ 02� 0�0 v <c G Q� NOTES 1. THIS IS AN APPLICANT DESIGN AND INSTALL PROJECT. 2. TRENCH TO BE JOINT WITH ELECTRIC, GAS, PHONE & CAN. 3. APPLICANT SHALL OBTAIN ALL NECESSARY PERMITS.. 4. RIGID CAP ALL SPARE CONDUITS. 5. IMPORTANT! DEVELOPER, GENERAL & ELECTRI:AL CONTRACTOR BEFORE BEGINNING SUBSTRUCTURE WORK, PLEASE CONTACT PGE UNDERGROUND TRENCH INSPECTOR AT LEAST TWO BUSINESS DAYS PRIOR TO REQUESTING INSPECTION. REQUEST FOR INSPECTIONS RECEIVED AFTER 12:OOPM WILL NOT BE INSPECTED UNTIL THE 3RD WORKING DAY (WORK NOT PROPERLY INSPECTED MAY BE REJECTED 6. APPLICANT CONTRACTOR TO LOCATE ALL UNDERGROUND FACILITIES BEFORE TRENCH & EXCAVATION. CALL UNDERGROUND SERVICE ALERT AT 811 AT L[:4ST TWO WORKING DAYS PRIOR TO DIGGING. 7. DO NOT EXCEED 300 DEGREES OF BENDS IN ANY CONDUIT RUN (INCLUDING BEND AT THE FEED LOCATION). 8. PROVIDE CLEARANCES AND WORKING SPACE P!=R PGE DWG. 051122. 9. PGE SHALL INSPECT ALL WORK AND PERFORM ALL HOT TIE-IN WORK. 10. BOX AND CONDUIT SIZES AND LOCATIONS SHALL CONFORM TO THE PGE ELECTRIC CONSTRUCTION DWG. 062288. 11. ENCLOSURES SHALL CONFORM TO THE PGE ELECTRIC CONSTRUCTION DWG. 062000. 12. APPLICANTS CONTRACTOR TO PERFORM ALL AND ANY NECESSARY INCIDENT/�_ TRENCHING, BACKFILL, COMPACTION AND PAVING. 13. SEE UTILITY COMPOSITE DRAWING FOR ACTUAL TRENCH & SUBSTRUCTURE LOCATIONS 14. 800 SERIES SKETCH LOCATIONS INDICATE PGCE WORK. TRANSFORMER DATA TABLE LOC.# TRF# TX. SIZE #GUST WIRE BUSH. ESD. KVA. PRI VOLTS SEC. VOLTS COORDINATE # SERIAL NUMBER MANUFACTURER 27 T-825522 100KVA 12 CUST 1 W/213 89 21 KV I 120/240V 35 T-176136 100KVA 12 OUST 1 W/28 88 21 KV 120/240V 18 T-763805 100KVA 13 CUST 1W/213 95 21 KV 120/240V - 65 T-37058 100KVA 15 CUST 1 W/2B 107 21 KV 120/240V CK) T-438013 100KVA 14 CUST 1 W/26 99 21 KV 120/240V 57 T-96278 50 KVA 6 CI ST 1 W/2B 50 21 KV 120/240V 86 T-548824 100KVA 12 CLIST 1 W/213 88 21 KV 120/240V 93 T-703418 100KVA 13 CUST 1 W/2B 95 21 KV 120/240V 76 T-285544 100KVA 11 CUST 1 W/2B 81 21 KV 120/240V 111 T-449587 100KVA 16 CUST 1 W/2B 114 21 KV 120/240V 119 T-32858 100KVA 13 C -ST 1 W/26 95 21 KV 120/24OV 149 T-494486 100KVA 12 C� ST 1 W/28 88 21 KV 120/240V 143 T-455764 50 KVA 10 C -ST 1 W/2B 77 21 KV 120/240V 137 T-153972 100KVA 8 CUST 1W/2B 64 21 KV 120/240V 130 T-836094 50 KVA 7 CUST 1 W/2B 57 21 KV 120/240V Project Management by: California Utility Consultants Inc 7591 N Ingram Ave. Suite 103 Fresno, CA 93711 Phone (559) 261-9880 Fax (559) 261-9707 STOCK DALE 2112 CIRCUIT PLAT 30275 PLAT- 3027274, 3027275 INS DIST: B CLIMATE ZONE: R VOLT CLASS: 1 LOADING DIST: SI LIGHTNING DIST: 2 NON CORROSIVE RMILE 151 161 LS2A PM 31174862 • �` • • SCALE: 1 "=40' SCALE 40' 0' 40' P,(D> DATE 1/13/2016 SHEE- El OF ES SHEF-TS SCALE AS SHOWN DESIGNER Cliff Lopes DRAFTER Cliff Lopes JOB BERKSHIRE RD CURB INSTALL CONDUITS A MINIMUM OF 24" FROM INSIDE WALL OF PAD .....-------------- 2" OF PEA GRAVEL REQUIRED ON TOP OF ROCK ......._....,M_ . .......: BASE TO AVOID DAMAGE TO CABLE. C PHASE - 1-833866 B PHASE - 1-353584 3-1100AL 21kV IN 6" A PHASE - 1-160226 TO 890894 �`- PULL BACK CABLE AND ROUTE INTO NEW PMI -9 ��\ UNUSED 3 LOT 4 in TIE INTO EXISTING 6" CONDUIT ca \ 3-1100AL 21kV IN 6" ----------- ��m D 1 0 �m D TYPICAL 36" X 52" PAD DETAIL 36" —P1 P1 P1- P1 P1 SW -516105 Q� SW -160226/ P8---/ 8' Group All Secondary and Service Conduits Together Near the Back of the Window Secondary Primary Conduit Section Conduit Section of Pad � I(D 0 19�-o 0 Detail A Placement of Conduits WALL LOT 3 SIDEWALK —ra _P C............ ............ ..... ... .._....._. .......-1-833866 TO J-46543 P1 1-353584 TO T-438013 P1 1-160226 TO J-59317 1-9 PADMOUNT INTERRUPTER APPLICANT TO PROVIDE PUE OR R/W AS REQUIRED FOR THIS INSALLATION. 8' CLEARANCE REQUIRED ON DOOR SIDES ON INTERRUPTER. APPLICANT TO INSTALL PAD & INTERRUPTER. APPLICANT TO COORDINATE WITH PG&E FOR INTERRUPTER SETTINGS PRIOR TO INSTALLATION. SCALE: 1 "=5' SCALE 5' 0 5' 10' O r- co 0) �I 00 DOOR SIDE DOOR SIDE —� z 6'4" � rco PMI -9 PROFILE VIEW R 2" Prior to installation ,Interrupters should be delivered to the PG&E yard for HIPOT testing and settings installation. Settings will be provided by Planning engineer to DLT technician. 00 00 00 00 00 TO T-548824 8 �--P 1----/// (((��I 0 ca a M 00 I O 157 �— 4' x 6'6" x 5'D IVT. BOX J-22073 N N N LO oLO 0 N(D co 00 r, 0 0� 0 a as A� Q1 00 00 00 00 00 00 J-59317 4' x 6'6" x 5'D IVT. BOX 42 ENCLOSURE DETAILS ARE INTENDED FOR CONDUIT ENTRANCE INFORMATION ONLY. PLEASE REFER TO JOINT TRENCH DRAWING FOR EXACT LOCATION IN REFERENCE TO CURB, SIDEWALK, PUE AND P/L. x CO 000 r mP') � wn rn U �t J I D_ — I V� 0 �0 Of 0 a. A� Q C) 00 00 00 00 00 00 SPLICE BOX 3 x 5 x 3'6"D IVT. BOX O 00 a J-46543 t 4' x 6'6" x 5'D IVT. BOX I ~ 155 0 1 1000 U N _i U) JN in LO o_ O n co -r. I zi 0— 1z) (L Oga :t� x(t v_ el �Q1 00 00 00 00 O _ )X o_ m a r2 o w r� 00 U tt I I ~ S � 0 O O ~ O Of F- 8 8 THROUGH SPLICE BO�Xj —P1 TO J-46543 SPLICE BOX 3' x 5' x 3'6"D IVT. BOX 99 1 STOCKDALE 21 12 CIRCUIT PLAT 30275 PLAT: 3027274, 3027275 INS DIST: B CLIMATE ZONE: R VOLT CLASS: 1 LOADING DIST: S LIGHTNING DIST: 2 NON CORROSIVE •• °\ THROUGH SF LICE E30X \ FROM 1-160226 P1 -*- SCALE: 1 "=40' SCALE 40' 0' 40' 80' ' ' £ rM N � " J l VD 3.9 FD 4 LOT 153 CL W I N LLj ww a f € r: : m_ ....�.. �.. ti 25'/39' W LOT 152 1 2 03 Z I Nn mT-96278 _,:50 KVA 57 «.._... Ln So SCALE: 1 "=40' SCALE (o L0 u,) ��€ %�` 40' 0' 40' 80' 1< CO �o N :D N 00 CO _ 't- cn w»w ISCO to M � ,.,,,«, ,,...,,, ,»�» »•»», _,»»» ,,,,;,,,, ,,,,,,,, ,».»„ _«...., ,.,,.. ::,,,,,. :....,.., ,:»,: ......... .,,,,,,,, w...., _.,,o„ »,_,» x,:.»_ ,»,_. •.,»... ... », «....�. _.... ..., - _ _ ,:,... >.... „».: _.., ..».. ,.... ., x..>.... ..•,.. ,.._.,» ..._», ..,4,,,,,,»�.�.»x _.._ _.-x ....F-wV,,.., ro 00 801 «:.:::. •_,. _ ..:x:......,.. BERKSHIRE ROAD can I I I REMOVE 125' OF 3-1100AL INSTALL 155' OF 3--1100AL SKETCH LOCATIONS 2 TO 5 NOT USED. PULL BACK CABLE AND IN EXISTING 6' CONDUIT. ROUTE INTO NEW PMI -9 195'+or- 627R4 8 3-1/OAL 21KV TO T-33555 3-1100AL 21 KV P1 P P1 P1 P1 P1 P1 P1 3-1100AL 21 KV P1 P P1 P1 P1 P1 P1 P1 515' 569' 3-1100AL 21 kV IN 6" CONDUIT TO J30688 FROM1 P1 —P1 P1 P1 P1 P1 SW5542339 �# �.�.;�,. � �.,,,,....._,,,,,,.x..._x,....:,x:�„»�;`.,x��,.���w`,a..:,w��..wu.»»,.M,,,�,,�..»,'�..�,»�,...�"..�..�.�,..M,N,».�.._.�..m,,.,_w...,.«_.o,,.>«::••»,»»»»,�..,,.w,.. .>T _.,»,..�, '�.��•`.,..,,,,µ,..�»..>_....o,.,...,..»»_.,.»».».,_,,..u_»x.,.»»,._,..,»»_.,».,,,..,,,,.»...,._...._„»»,»,,.,»_..».._..,»..�..,,,,»�,»,•,.,,».,.,,.�,w»w.,»,,,_.,..�..w,_..,»»._.»-__..,:..xx.�,.x„».,»..._»_..»,»_�»._.,.,.,.. ».,,....,,.,»,»»:,.,.,......,.,,,,,».».».»..............a_.>„x...»...,�,,.:x,....,,,,..,,w,,,,,,.,,,,,:,,,».........�,,.., ..»,..k»»,>.:�,.A,,.�.,,,�•;•'.",,,,.:.,.,..":""'"",.m,,.�`w •, m',,..,,: m..."�rr' »..,w-•,,.w....,,»„»,.:._,.,.,�,""..»,,.""":"^v,.,,�».'""^'^<^,»,,,,.,.,„..,.,...,,.,».�»...+.,.....w.»,»max "”" ,»....,.»,:...-,. ,... r».,..�._.-w,-.�...w..».......e.«.,....,...:»,......_..:...».»..exµ..',..�'e-",�,._.>n,.,'.."....», � 5 627R3 i ; 3 i � � :, ", <;�• 9 s s in 515' 569' J-19368 7 I a i £ I #t 802 SW 890894 i � � I LOT 12 � � £ ' # � � 100 AMP i 1 v' € v' L.S. SERVICE .t J SW 554399 I { f SW 319643 5'/19' LOT 171 LOT 170 LOT 169 -sv1- N 0- O I LOT 173 LOT 172 f > VD 5.3 LOT 11 LOT 10 LOT 9 LOT 8 I LOT 7 LOT 6 - LOT 5 ' LOT 4 LOT 3 LOT 2 > ( # E SCI 10,000 FD 5.8 € i SKETCH LOCATIONS 11 NOT USED. �,, N 150'/25'/189' ? VD 5.6 I i { VD=3.2 'n a _ VD 5.3 ! LOT 168 FD 5.0 J -j ; . f VD 3.5 FD 5.3 ; ! £ € 25'/39' I I a I FD 3.6 , (( LOT 1 (Hy VD 5.6 / Q o >€ € l i FD 5.2 3 0 0 ? € 60'/25'/99' 60'/25'/99' 60'/25'/99' 60'/25'/99' 60'/25'/99' t 60'/25'/99' 60'/25'/99' , 60'/25'/99 j 60'/25'/99' ; 60'/25'/100` 12 N £ b £ £ £ , , ' , T I ; VD 3.5 60'/25'/99'60 /25'/99 f 60 /25 /99' 60'/25'/99' e0. a 25'/39'€ FD 3.6 ' i 22 5, ✓� `'� ��` 60'/25'/100' Z 3 £ I£ / 627X7 }j{ I € s T 23776 w . 0.� . _ 25 KVAEs > 4. --.....'.... ,»,.. Y.' _,».,»....:.,..,,a,�»..M...,...,... ,»,»..,._.,..w_.x., ..»...»,.»....c. _.w.»..w .,M..»„ d,.....,..,..._... «....».x_,x.,,»x__,,.._.k»......._»x,. »x.. _ �'.. a e"� S', ,ice 00 I I - - - --- _ \ 32 26 / 'l "' a a a 13 '''; L 0 T 167 s CRYSTAL 355'/369'1CASCADE LANE 235 272' D I 400' 437' 3 ' 627X8 vs� I I .,,..:w . m .. „ w w » w » �� 627X6 PULS as PULL 20 _,x i - _ «,. , \� �37�w 111 �� fit•.-(�1 i�f f�f € »�e „P1:....,. P1....,.,_,__ 1 P1 P1 P1 P1 P1 P1—� q AS1, _.... U i I �, t t f N - -I•• „--- ,., , .._...,...._....,.,.,..,»..,.,w�._,w,,.,...... »,,,,,,,», --, , •,.,.., »,»,»„ ,,,,,,,,,,,,,, x.,,•»,»..._«...__,<«,. W L 1 Y S W� » f x z /' �'--51 S1 N S2 S2 S1 N N J� /` » d _ _ »» _ __,,....»«». », ,K.,. ,., 25' 39' f I r ys S1 33 Sl Sl $1 Sl Sl N S2 S2 S1 1 S S IN / 60'/74' 60' 74' , O ',»». 5.,,,,., y M ? "M ,x, # _ ..„ I / 60 74 31 a f` St S11 S1 S1 �`'� S2 fr _. : 39 / i 120 134 60' 75 f O/. / 160' fi 75,, ! T-1761 29 60' 74' d a;14 69' 36 f / / \ 2'4 120'x/134' 55'/ r"' S � 7n T-82552236 10o KVA 34 s 16 CK) O O 30 10o KVA 25 f { 23 I I <) _ ' o , € f 28 _'; '._ 2 7r, »....»..» 25'/39 12 COST ! f I 12 CUST �r S1 f 25'/39' ESD 88 KVA t ESQ 89 KVA € % T-76385 120'/134' 25'/39' 25'/39' 25'/39' 25'/39' 25'/39' 25'/39' 25'/39' 25'/39' 25'/40' ; 25'/40' LOT 166 ; 100 KVA cn '27 IF I f 25 /39 , 25 /39' } '° 13 CUS� 's 3 LOT 71'/25'/11o'i r ,I a 25 3925 39' T 1 13LOT 14 I LOT 15 LOT 16 LOT 17 LOT 18 LOT 19 LOT 20 LOT 21 I LOT 22 LOT 23 LOT 24 °- a I / / ESD 951 KVA 19 3 I l IE) 45'/25'/84,` t i 40 (III f i 1 1480'/517' a " t I $4 LOT 161 z LOT 162 LOT 163 LOT 164 LOT 165 ddd '( I s 3 fi" SI , ' i € � J-59317 _.,.»,..,.m..»»,..,_.... 2 5 i 3 _..,,x..� 3 .... .... i{ 42 �� � �......�....."___...�.,_.vw.A,»,._.__...__.w..w.,H,»x_....�.»-,».___»::,.�.:,:._.»�..«.__.«».:x._»».w__.f.._.,....�.,.«,....,,__o,.......».,,.,w»r_,w,..... .._:.,_:»x.,»_»...«».�..:,w_....__..._ ,.,,._....�._.._»�.»»,.._.,,,,_...... .... i ' wq 8 cr0 SHEET E3 LOT 35 \ LOT 34 25'/39' '{ VD 3.8 25'/39' ;., FD 4.1 LOT 36 72 25'/39' 74 w..�� y P. s LOT 37 2 r S� Q a f 25'/39' �1 T-285544 76 100 KVA 3 $ ESD 81KVA LOT 38 77 _ Q 0 N ; '.3 25'/39 78 w PE, O I LOT 39 N cptn t I la 71 380' 394' LOT 33 ? LOT 32 LOT 31 LOT 30 1; LOT 29 LOT 28 LOT 27 LOT 26 LOT 25 i 43 # � i } 485 522' a 80'/25'/119' VD 5.7 FD 5.7 —P1 P1 P1 —pi P1 P 70 P w www N N f t 25'/39' 4 25'/39 LOT 103 LOT 102 105'/25'/144' 105'/25'/144' 112'/25'/151' ; 112'/25'/151' 125'/25'/165' ; 125'/25'/165' 125'/25'/164' 125'/25'/164' VD 5.8 aaI %I FD 5.8 63 580'/628' 69 PULL 627W6 P1 P-- 1 P P1 pi Pi P1 P1 P1 'f 1 (� Pf T x.:..,,. P -- :i 1 P� .., P 1 1: PULL 5 W S1 01 S1 S1� S2 S2 S2 S2 M 125'/140' 67 � 65' 80' T-37058 65'/80' 62 Gi) v' 66 100 KVA - 15 CUST O ESD 107KVA # 25,/40, ; I 25 /40 65 25'/40' 25'/40' OFF SET ST LT j ! FOR TX CLEARANCE x LOT 104 LOT 105 LOT 106 LOT 107 I LOT 108 CLARION CHANNEL LANE P1 P 1 P1 P1 P1 P1 �1 1 fi P1 125'/140S1 N� 60 61 25'/39' 25'/39' VD 5.1 t FD 4.5 LOT 109 LOT 110 3 I . xV,,,..•»»»_,,�a�`°»»»_.,»»,»,. �j a 460' 491 \ as s27W7 ,IIa E Ia a P1 —pi P`f P ^NSC 4.z2 S2 - 59 130'/145' 4? < Vp 46 / I 25'/39' 25'/39' LOT 111 LOT 112 i LOT 160 LOT 159 LOT 158 LOT 157 f F i i 120'/25J1 59 70'/25'/110' 110'/25'/`150': 110'/25'/150' 45 52 300' 331' 436' 473' 627W8 PULL Pf-�--- P P F 1 1 FT F1 q ....P,I, r 2—S2—S2 W S2 S2-- S1 S1S1 65 /80 T-438013 65'/79'51 130' 144' 47O100 KVA �' 53 48 � 50 � - � 1 14 CUST o / ESD 99KVA / 25'/39:'• 25'/39' CK) 25'/39' 25'/39' r LOT 113 LOT 114 LOT 115 LOT 116 LOT 128 g LOT 127 LOT 126 LOT 125 1 LOT 124 LOT 123 LOT 122 LOT 121 LOT 120 LOT 119 1 LOT 118 LOT 156 r 3 r�! 25'/39' f' 25'/3c VD 4.0 FD 5.0 LOT 155 LOT 117 i 6 CUST - E ESD 50KVA / /, F gg S ♦��. I . 1f 1 / SHEET 55'/25'/94' l VD 3.9 FD 4 LOT 153 CL W I N £. ;t 55 25'/39' a :°s m_ ....�.. �.. ti 25'/39' W LOT 152 1 2 03 Z I Nn mT-96278 _,:50 KVA 57 «.._... LOT 117 i 6 CUST - E ESD 50KVA / /, F gg S ♦��. I . 1f 1 / SHEET SHEET E4 € if 627R2 t. 25'/39' 2E; y<sa LOT 40 25'/39' 100 y 0� 0 I a 0 I s. N P824 \: LUSTROUS LANE LOT 41 65'/25'/104' SY 1--.1 65'/25'/104' LOT 101 LOT 100 _r t5 25'/39' S1sk2 :I ~ 25'/39' I E f a FD 6 3 25/39'1. 135'/25'/174'\ 25'/39' :. VD 5.9N w FD 5.1 << 627W9 LOT 129 --'s4 99 25 /39' p C97 S2 LOT LOT 130f ` 96 25'/39'1/ %LOT 131 f ' r LOT 99 25'/39'' VD 5.9 € ; a 3 FD 5.7 O104 ; , � s CL L O T 42 25'/39 N j a # £ If ; I i ( LOT 98 LOT 97 LOT 96 LOT 95 i a : �I f » N... 'a 65'/25'/104' FD 4.1 FD /25 LOT 43 3.7 65'' /104 65'/25'/104' ' 65'/25'/104' 105 � I ' , to N s t I � f 25'/39' N °- ..__..._......:..........-,..,....��....u:,m.._.,....w»».,....»...�...,»m_:~�w�'" I ...»,.....,.....,,._....s.m:. m�,. ?.�..w_w»».»».»»�.m,:.:....,...,�m».._...��,�.�,w ..w.».,w•_...` � �.»..»,..�' ...m:.,,.».. 25'/39' SA E as 107 115 LOT 442 3 PULL 215' 252' BLACK PEARL COURT 355' 369' O106 €' PULL 627W1 1' I� P1 P1 P1 P1 01 01 01 O I LOT 94 75'/25'/114' ' 75J25'/1 14' 75'/25'/114' 68'/25'/107' VD 3.7 FD 3.7 V11 -XX,` /// � � # �' ^,ef' o✓ , .^� �l 3/r ' f �'' �/ �/,+ % /�/ r ''"� /�:r �'sd`/ . /'}�,dk ' y" s . � ,� _/ s�" . ,.'t .y : � ' /„a' �/ ,� ,� /' : % <' i '/^' .'is``^``� 3�f" ,/ �/^ �,. // / / , </. ,'. -.. •A/,, , s1 f`.. /... ,,.�' Fg, •>,' J _.f .,c..,.s :.F,,,,, -.,G... ,.:a��..�eG „s..•./:>r,c',�;a'Ff.',^�%rr,..^:/sk �. .,c / •� -�' r<< .b` i� /' s:'. o". •, f �f _,p t,,:.....m,.. ................ ..c......s.:! ::..::. , i .e :._.. -�• .:,�.. .-�,';'; 156 LOT 151 ET E4 E o' SHE 130 167' i i I Ln 58 j> t 25'/39' t : I > F 5 75'/25'/114' 75'/25'/114' 75 /25'/114 75'/25'/114' £ 75'/25'/114' 75/25'/114' , a u' ......... .." _.... .... .,..,-... VQ 3.6 VD 5.7 €/ I SVS 25'/39' FD 3.8 I I FD 5.5 627X3 �s a I 80 LOT 150 ;._r....._.....v» # t • .._ 62,..m»2 w7 ^.m^ .,., ..., ...,..... ,w € LOC 90 8YJ 89 €, RIVULET RUN COURT LOC 83 235' 249' \ \ 90 s27x1 PULL �.,.�»...�,• � ...._ . ,� f �...,�..»w Pr ,,....»... ... ,..,..• ».»»,,...»i _.:..... ; fit.... -£ » . --- ...... 1 `�-�-�-P1 N. » �w ud .......... f 84 - 1 s2 s2 s7 s7 N 91 ! C14s1 m N:....,,... S7 w _w S N 95 I t 60/74 7r 94 T-703418 KVA 60/74 C�2:) } : 88f / 60'/74' 4-01C S1 --S1 T-548824 60 /74 5151 120134 S1 S2 1�ccusT 87 ' 12 cusA 100 KV85 v'130 83 ESD 95KVA - _ / \ ESD 88KVA i 25'/39' 25'/39' 93 25'/39' € 25'/39' 25'/39' 1 25'/39' 86 25'/39' 25'/39' 25'/39' 25'/39' LOT 132 LOT 133 LOT 134 LOT 135 LOT 136 LOT 137 LOT 138 LOT 139 LOT 140 LOT 14' , LOT 93 65'/25'/104' 60'/25'/99' VD 5.4 FD 6.3 LOT 92 LOT 91 65'/25'/104' £ 65'/25'/104' VD 3.7 FD 3.7 1 a P1 P1 P1 P1 P1 -c7-p1 P1 -p1-p1 P1 P1 P1 " SEE TOP RIGHT OF CORNER 110 �w _ w £» f » ,..::.,,... t ............- ..,-,.w•. M _....._ . �� f _ m , w� mw. �» m ' JT m OF SHEET E FOR __ LOC 156 109 mw»,�.w.», .. • AND 157 ' S2-F77"240'/254' S2 S2 S S2 ' S S2 S2 S2 S2 S2 S2 S2 S2 wi -;; ». m 116 '/ € 60' 74' 1 120'/134' �� € 240 254 `y T-449587 J »46543 £ 108 / 100 KVA 155 / 16 CUST / ESD 114KVA € 25'/39' 25'/39' 111 25r/39' 1 25'/39' 251/39, I 5' '/39' ' LOT 74 LOT 75 LOT 76 s LOT 77 LOT 78 LOT 79 L00KING GLASS LANE 4 a � I a } LOT 73 LOT 7 2 0. ' a a 1 65'/25'/104' 65'/25'/104' I 0 VD 6.0 a i FD 5.7 I I LOT 71 1 LOT 70 65'/25'/104' 65'/25'/104' LOT 69 I LOT 68 85'/25'/124' 85'/25'/124' I VD 3.8 FD 4.1 627W2 LOT 90 1 LOT 89 65'/25'/104' 65'/25'/104' t w.�_w»»»_ww�mwwmw..». .:< . ,,:.... ....,.. .....».�w,»:.»: k ».»_» :. 121 �. O117}N S1 s1 S2 S2 60'/74' 60'/74' 118 T-32858 100 KVA 120 s 13 CUST ESD .95KVA 25'/39' 25'/39' 119 25'/39 25'/39' LOT 80 LOT 81 LOT 82 LOT 83 LOT 67 LOT 66 155'/25'/195' 155'/25'/195' VD 5.8 FD 5.5 � r i f a 154 � 146 545' 582' s27u7 TWINKLE LANE 320' 334' P1 P1 -pi Pi P1 P1 P1 P1 P1 P}1 1PULL �-P1 P1 - - - P4 - -::7-P P1 P1 P1 P1 P1- »:,,,.:..»�.»»„.Y,.,.., �. w„ .. .t$.,........,.......,,.. :..,....•....,...,..Twp...»....».,,,»•»».•..........:..:.m �«,»..,� m..�..w...,...., yit•:,....::,.,.,,,,» „....,4.. ........... ,�,. ....�..,,....- »»,:.» .........»..•.w ,> mw. t,..,, z.p.,_"`».»"'.","""""""";"...- wwwj ,I...... �' »,»,»»• »..». _.. ». _ s� ,, w,•,, �. _mS1 S1 1 5 S 1 S N SZT ee2 N , i 153 � s1 s1 7 ' 0 84 135 �147 14/9151/70 84' b / € - € T 94486 10 KVA O € 3 f _ % 12 CUST # 25'/39' 25'/39' # ° ESD; 88KVA ' £ 2 `5'/39' W 25'/39' 25'/39- 149 25 /39 € € LOT 45 LOT 46 LOT 47 LOT 48 LOT 49 ! LOT 50 V LOT 65 LOT 88 LOT 87 25'/25'/64' VD 5.9 FD 5.2 t x L f; 25,/39, "r » k.� 25'/39' LOT 86 cq f {` Y , Y 627W3 f ' t r' l n / Q124'. 123 N LOT 85 1 25'/39' 1 , `f 25'/39' ; LOT 84 YE} LOT 64 105'/25'/145' 105'/25'/145' LOT 142 127 100'/114' S1 S1 - 25'/39' 126 N 148 25'/39' LOT 146 25`/39��� LOT 143 N a� CC, 27u4 129 co ; o T-83609 7 CUST ESD 57KVA LOT 144 130 o� 131 r 10 25'/39' LOT 145 r� 25'/39' VD 3.7 FD 3.5 a 1 P, 00111- RUSH TERRACE: 132 W .tt5�k 1 N I 5 ' S f � k LOT 63 LOT 62 LOT 61 LOT 60 W co � € m f 110'/25'/149' 110'/25'/149' 115'/25'/154' ' 115'/25'/154' VD 5.6 VD 5.0 FD 5.2 FD 5.2 (1741) 627U6 PULL 240' 254' � P1 -n --P7 P1 P1 P1 P1 P1 P1 P1 . } 'S 145 M s2 s2 s1 s1 rN 140 60' 74� o 60 /75' T-455764 / 50 KVA 142 j 10 CUST S ESD 77KVA +� 25'/40' 25'/40' 143 25'/39' 1 25'/39' E f LOT 51 LOT 52 j LOT 53 LOT 54 STOCKDALE 2112 0IRCUIT PLAT 30275 PLAT: 3027274, 3027.175 INS DIST: B 'LIMATE ZONE: R VOLT CLASS: 1 LOADING DIST: SI LIGHTNING DIST: 2 NON CORROSIVE � 627U5 ,i . '�;.... SCALE: 1 "=40' SCALE 1 � 40' 0' 40' s;0' P1 P1 P1 P1 \ .�........,.....v...:,.:..... ..?. w.w.., ..» L ... ..� y .:.w...,w., H �...w 135 133 O Nj---S1 S1 s1 S1 N . S1 S1 �N 39 f 1 60'/74' 5, T-153972 60'/74' 1 15' 129' 7 138 50 KVA136 f 134 � : 2 ` '/39' a� / 8 CUST / 1 VD 5.5 f ESD .64KVA Ir 25'/39' #FD 5.4 M € 25'/39' 137 25'/39' € 25'/39' t S LOT 5:� LOT 56 LOT 57 LOT 58 LOT 59 5 t T33555 300 30 wwW n nn z z Qm U I I O ON00 wN �Z (0 � n(0 N 1 /, OA 48710 554,399 319643 VICINITY MAP Q I ICn r I Q T27043 w 00 100 -BO 1 OA I w Q I 0 MENSEN DR z� `31998 < GOZUM DR / 1 OA 57604 T38542 / 100-B0 110 OA J19368 PHISTO T7 9 9 21 100 -Co cam-- T53174 1 /OA T69945 0 100 -BO I I I Q 100 -Co w J m 0 0 a- J37791 890894 �� ��ry �� BERKSHIRE RD. 1 100A c 1 100A 8265E r __j /OA J D,q LZ.,pi P'P1 PP1 P1 P1 J30688 98927 I I T26805 T96..75 P, P, P, ' P, P' P, P' -I T515 9 3 / 6 5 E 25 Co a00 1 100 CoC8201 1 fo' AO CRYSTAL CASCADE LN a a T68962 65E \ 1 100 Co z T23776 �;y P1fLi -���� P1 P1 P1 P1 P1 Pi TV 25 aCal: 1 �- -' T92010 _ U J14362 �- U --" T-17 o 100 A� 6136 T-825522 � Q W QW100 KVA 100 KVA �°-� T-763805 (J) 10 z I m w 12 CUST 12 CUST 100 KVA I _ (� Of .v a 13 COST -� ESD 88KVA ESD 89KVA J-59317 ��1 � � Q I IO U A� A� 1 I a0 ESD 95KVA 1 Q 10 w 10 O Q 1 m I = 1 1 O 1 z U U 1 I aC� I w .- � m W I �- a _Z Q w I I= � 1 SHINING CRAG[ AVE cn IQ I acn 1 L o CLARION CHANNEL LN m 1 act� 1 /OA 1 /OA P1 P1 P1 P1 P1 P1 P1 � I P1 P, P, �EL�T �„ P, P, P, P,—� T61552 T41087 _I;y(Ejt--P' P' P' 50KVAU 50 CO J23199 1 50 CO 4 T-37058 T-438013 6 CUST Q F- 00 100 KVA a KVA ESD 50KVA 0 100 KVA 4 a 15 CUST 14 CUST BO 100 KVI ESD 107KVA ESD 99KVA I (*I 11 c AO B� r T66370 A� a ESD 811KVAly�a I SILVER JEWEL LN I I T77017 100 AO A a a 50 Co /-- J61 68 RIVULET RUN CT ,�� a - 1 OA 1 /OA I Ir.; T5 413 a D�F�P,�E1.��'y —P, P, P,--��}:'�,v�� T85068 8 100 A� I T-703418 T-548824 �T1 J-22073 50 Co 100 KVA 100 KVA a 13 CUST 12 CUST iESD 95KVA ESD 88KVA BO EO a I r.. SILVER JEWEL LN CL P1P1—� FX ,�. r'�'y P' P' P' P'��'� COOL RUSH TERRACE T-836094 �--� Iyi i T-449587 T-32858 50 KVA U w Q J-46543 100 KVA 100 KVA 7 CUST N� �OA �QA 13 ESD 57KVA 1 ESD16 c1 CUST 100 ESDC95KVA g� Z -� c� o T14664 co 100 co T39370 T93069 � z 100 AO 100 AO I a W In � =I O a BLACK PEARL CT. L 1 Pt P1 P1 P1—TV ry Ff}--P1 P1 P1—�� �y �;--P1 ',�' T-494486 T-455764 T-153972 100 KVA 50 KVA 50 KVA 1 12 CUST 10 CUST 8 CUST ESD 88KVA ESD 77K\iA ESD 64KVA I co co co Prior to installation ,Interrupters should be delivered to the PG&E yard for HIPOT testing and settings installation. Settings will be provided by Planning engineer to E,LT technician, CIRCUIT SKETCH LEGEND INSTALL DESCRIPTION —P1 P1 — PRIMARY CABL= - 1-1/OAL EPR ENCAP IN NEW 1-?" —P9 P9— CONDUIT PRIMARY CABLE - 3-1100AL EPR ENCAP IN EXISTING 1-6" CONDUr"- EXISTING DESCRIP I ION 1 PHASE PRIMAR" UG CONDUCTOR - SIZE AS SHOWN ' 3 PHASE PRIMAR" UG CONDUCTOR - SIZE AS SHOWN INSTALL EXISTING DESCRIPTION f\ - 200A SEPARABLE DEADBREAK CONNECTOR r 2D3A SEPARABLE LOADBREAK CONNECTOR F C– 6DDA SEPARABLE CONNECTOR ® ® PA -)MOUNT TRANSFORMER - SIZE AS SFOWN �v PM -II PADMOUNT SWITCH / INTERRUPTER LOiQBREAK 200A 3 WAY JUNCTION 600A 3 WAY JUNCTION 60UA/200A 3 WAY JUNCTION n 'ELI FI FAJLT INDICATOR STOCKDALE 2112 CIRCUIT PLAT 30275 PLAT: 3027274, 3027275 INS DIST: B CLIMATE ZONE: R S.S.D. VOLT CLASS: 1 LOADING DIST: SI LIGHTNING DIST: 2 A I / \ A I - - - - i-.