Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3.2-538
LIS T SHEET 1-2 SHEET 3 SHEET 4 OF DRA WINGS TITLE SHEET AND DETAILS COFFEE RD AT STOCKDALE HWY OLD RIVER RD AT MING AVE CITY STANDARDS CAL TRANS STANDARDS ES -1 A, ES 1 B, ES -8, ES -13 CONVENTIONAL SYMBOLS - - - SECTION LINE RIGH T- OF- WA Y CEN TERL INE RAILROAD TRACKS X FENCE CITY 0� 3A/< S -D DEPARTMENT OF PUBLIC WORKS RED LIGHT CAMERA INSTALLATION COFFEE RD AT STOCKDA E HWY AND OLD RIVER RD ATMING AVE --------- EXIST. CURB & GUTTER --------- EXIST. A.C. FLOWLINE EXIST EDGE OF PA VEMEN T GUARD RAIL IMPRO VEMEN TS LEGEND ® TRAFFIC CONTROL CABINET 0 POWER CABINET GK1 CAMERA SYSTEM WITH FLASH di SLIMLINE CAMERA W/FLASH NEW PULL/JUNCTION BOX o EXISTING PULL/JUNCTION BOX D TELECOMMUNICATIONS LUMINAIRE o REDFLEX MAPPING RADAR I 1VVtJL' u l LVUtil lVly LOCATION MAP 1 S TA TE OF CALIFORNIA BENCHMARK SEE PLAN SHEETS BASIS OF BEARING SEE PLAN SHEETS NO TE. - THE CON TRA C TOR MUST POSSESS THE FOLLOWING VALID LICENSES: CLASS A OR C 'O OR c-12 sb n oo'% aft -m 4 TRAFFIC SIGNAL POLE WITH RADAR MAPPING DEVICE 4"0 STD. GALVANIZED STEEL PIPE (ASTM A53 SCH 40 4 J" O.D.) INLINE FUSE TO PROTECT EQUIPMENT REDFLEX PMC SIGNAL S CABINET CL ___, CTRAFFIC SIGNAL CL C:) FRANGIBLE BASE (CASE JUNCTION MAST ARM ALUMINUM OR CAST IRON) 14" BOX N, I _17 SQUARE AT THE BASE K- 0 r 0 777,, x"ll 114- CN 0 SIDEWALK OR ISLAND ...... %rye jVie.,. ...,j--------- i GROUND LINE RADAR MAPPING DEVICE 7-7 RED LIGHT CAMERA SYSTEM 7\ RED PHASE CONNECTIONS SCALE: N.T.S. DEVICE (PREFERRED OPTION) (ALTERNATE OPTION) RADAR MAPPING SEE POLE SCHEDULE NOTE: PROPER PLACEMENT OF RADAR MAPPING DEVICE TO BE DETERMINED BY REDFLEX CONSTRUCTION MANAGER. CONTRACTOR TO SUPPLY AND INSTALL GROMMET IN DRILLED HOLE TO PROTECT WIRE. AFTER WIRE IS PULLED IN, THE HOLE SHALL SEALED SO IT IS WATERPROOF. (TRAFFIC SIGNAL POLE W/RADARRED LIGHT CAMERA SYSTEM MAPPING DEVICE I SCALE: N.T.S. CD - I rl REF. RCO-SUFO: POLE F2 STANDARD TERMINATION PANEL (16"x12%7") MOUNTING KIT POLE DIAMETER RANGE 4"-12" MAX. MINI CAMERAS ON NEW POLE INOT TO SCALE VER 1( DATE YYMMDD) I INITIAL RED LIGHT CAMERA SYSTEM SCALE: N.T.S. REVISIONS DESCRIPTION 1 "X36 )I X4 to LENGTH AS REQUIRED BY MANUFACTURER 23"(MIN.) B.C. FOUNDATION TEMPLATE j `j j POLE — TYPE 1 1111kilmall0=101• Eell STANDARD TERMINATION PANEL (16"x 1 2"x7") MOUNTING KIT POLE DIAMETER RANGE 4"-12" MAX. MINI CAMERAS ON NEW POLE 0 GROUND ROD (3/4") BOUNDED TO POLE & BACK TO RTS CABINET __--1"0 ANCHOR BOLTS (4)X36" (ASTM) A-36 OR A-307 13 J" BOLT CIRCLE FOUNDATION MAY BE ROUND OR SQUARE RED LIGHT CAMERA SYSTEM SCALE: N.T.S. I RED LIGHT CAMERA SYSTEM SCALE: N.T.S. I POWER PEDESTAL rI REDFLEX PMC JUNCTION BOX EXISTING METER SOCKET XX" V jj,jjjFx . / '�� �,f � jj.:jjj��j. :.,. ' ,. 17 jjj�jj j�jj _...�::.N..........................;.........:...,-� j `• .......,...�:...... «._ ...........n�_...�� jj POWER CONNECTIONS RED LIGHT CAMERA SYSTEM (PDP) SCALE: N.T.S. MINI CAMERAS ON NEW POLE / REDFLEX SIGNATURE mv- DRAWN B� J.LORD REDFLEX DESIGNED BY: I-FREY TRAFFIC SYSTEMS INTERNAL REVIEW CHECKED BY: 23751 NORTH 23RD AVE PHOENIX, AZ 85085 AS -BUILT, VERIFIED BY: PH: 623-207-2000 INSTALLATION CONSTRUCTION RED LIGHT CAMERA SYSTEM SCALE: N.T.S. RED LIGHT CAMERA SYSTEM Comms I SCALE: N.T.S. I lr—\/ r—1 At -+f I A K I r -N REDFLEX GK1 SYSTEM "- 11 ro—'s RED LIGHT CAMERA SYSTEM 0 SCALE: N.T.S. APPROVED BY: CITY OF: BAKE RS F I E L D, CA PUBLIC WORKS DIRECTOR / CITY ENGINEER DATE REDLIGHT PHOTO ENFORCEMENT RECOMMENDED BY: RECOMMENDED BY: DETAILS DEPUTY CITY ENGINEER -1 DEVELOPMENT SERVICES ,AutoCAD Tsmpkft 2012-01-01 "5 > DRAWING NO. 1071 102 SIZE SHEET NO. D CONSTRUCTION NOTES ❑1 THIS IS A GK1 SYSTEM. ALL CONDUCTOR CONNECTIONS TO BE MADE WITHIN THE MAIN SCENE CAMERA ENCLOSURE AND INSIDE THE POLE MOUNTED CABINET THAT WILL BE INSTALLED BY THE CONTRACTOR, SEE POLE DETAILS. 0 CONTRACTOR SHALL TERMINATE AND LAND ALL POWER CIRCUITS INTO REDFLEX POLE MOUNTED CABINET. Q3 INSTALL INLINE FUSE HOLDER (#HEB-AA) ON RED PHASE CONDUCTOR WITH 5 AMP FUSE (#MEN -10) INSIDE CITY CABINET AND REDFLEX ENCLOSURE TO PROTECT EQUIPMENT. TERMINATE #14 WIRE TO RED PHASE AND NEUTRAL INSIDE CITY TRAFFIC CABINET. SEE CONDUCTOR SCHEDULE FOR APPROACHES. (NOTE: NOTIFY THE TRAFFIC OPERATIONS DEPARTMENT OF THE CITY 24 HOURS BEFORE CONNECTION). ® INSTALL A 40 AMP CIRCUIT BREAKER INTO POWER PANEL FOR 120V SUPPLY TO REDFLEX POWER DISTRIBUTION PANEL. 0 INSTALL TWO SLIMLINE CAMERA ENCLOSURES, ONE 500 WATT FLASHES ON REDFLEX POLE, ONE SLIMLINE TERMINATION PANEL TO BE INSTALLED BY THE CONTRACTOR, SEE POLE DETAILS; AIM AT MONITORED APPROACHES. ® INSTALL SLIMLINE CAMERA ENCLOSURE AND 500 WATT FLASH ON REDFLEX POLE, SLIMLINE TERMINATION PANEL TO BE INSTALLED BY THE CONTRACTOR, SEE POLE DETAILS; AIM AT MONITORED APPROACHES. 07 ATTACH MAPPING RADAR DEVICE TO MAST ARM OF SIGNAL POLE. RUN CAT5E CABLE FROM MAPPING RADAR DEVICE TO REDFLEX CAMERA ENCLOSURE. MAPPING RADAR DEVICE TO MONITOR SOUTHBOUND LANES 1-6 AND NORTHBOUND LANES 1-5. ® INSTALL FOUNDATION, POLE AND GROUND FOR REDFLEX EQUIPMENT. SEE DRAWING FOR LOCATION. SEE POLE DETAIL. Q INSTALL CAMERA ENCLOSURE ON REDFLEX POLE; AIM AT MONITORED APPROACHES. 10 INSTALL A FLASH UNIT ON REDFLEX POLE, AIM AT MONITORED APPROACHES. 11 CONNECT POLE TO STRANDED BOND GROUND AND GROUNDING ROD IN POLE FOUNDATION AND TO SYSTEM GROUND BONDED BACK AT THE REDFLEX ENCLOSURE. CONTRACTOR SHALL PERFORM THREE-POINT GROUND TEST AT EACH MAIN CABINET OR ENCLOSURE. GROUNDING SYSTEM MUST YIELD RESULTS BELOW 10 OHMS AND DOCUMENTATION FROM THE ELECTRICAL CONTRACTOR MUST BE PROVIDED TO REDFLEX. NO ADDITIVE IS TO BE PUT IN THE GROUND TO ARTIFICIALLY YIELD THE DESIRED RESULTS. 12 PULL ROPE TO BE RUN THROUGH ALL CONDUIT FROM THE REDFLEX ENCLOSURE TO ALL REDFLEX EQUIPMENT. ALL SPARE CONDUCTORS/WIRES SHALL TERMINATE AT THE JUNCTION BOXES, CAMERA ENCLOSURES AND CABINETS. SPARE WIRES SHALL BE TAPED AT THE END, CONTINUOUS IN LENGTH AND IDENTIFIABLE WITH PERMANENT IDENTIFICATION BAND AND TAGGED AS "RTS". 13 CONTRACTOR SHALL COMPLETE AS MANY POTHOLES AS NECESSARY. CONDUIT TO BE BORED OR TRENCHED TO MIN. STANDARD COVER DEPTH REQUIRED BY THE CITY (24" MINIMUM). 14 VERIFY IF EXISTING SIGNAL HEADS HAVE LED'S INSTALLED. IF NOT, INSTALL RED AND AMBER GELCORE LED'S OF THE TYPE APPROVED BY THE CITY -VERIFY BEFORE INSTALLING. IF NEEDED, ADJUST REDFLEX CAMERA SO IT IS VISIBLE TO THE SIGNAL HEADS. 15 REFRESH STRIPING (VIOLATION LINE AND LANES ETC) AS NEEDED AT THE MONITORED APPROACHES. 16 INSTALL WIRELESS COMMUNICATIONS INTO PMC. 17 TERMINATE POLE TO REDFLEX POWER CIRCUIT, SEE CONDUCTOR SCHEDULE FOR DETAILS (HOT AND NEUTRAL). LEGEND ® TRAFFIC CONTROL CABINET Gi POWER CABINET GK1 CAMERA SYSTEM WITH FLASH Li SLIMLINE CAMERA W/FLASH m NEW PULL/JUNCTION BOX o EXISTING PULL/JUNCTION BOX MT TELECOMMUNICATIONS )Z� LUMINAIRE REDFLEX MAPPING RADAR 1, 5'-0" F.O.C. REDFLEX GK1 3—CAMERA SYSTEM W/250 WATT FLASH BA -COST -01 (35.354793, —119.092474) 0 1 2 3 8 9 1011121617 REDFLEX SLIMLINE CAMERA ENCLOSURE W/500 WATT FLASH AND STP BA -COST -04A 13 F4 6 8 1 11217 ,�, _. S �_. ___ GAS__ ___ GAS p. CABLE STnr.K)AI F HWY I m 0 MAPPING RADAR DEVICE _ -6N INSTALLED ON (MAST ARM OF SIGNAL POLE X1 7 13 5 REDFLEX DUAL CAMERA SETUP W/PDP & STP; TWO SLIMLINE CAMERA ENCLOSURES, ONE 500 WATT FLASH AND AN 8—PORT SWITCH BA -COST -02 Cam= SIGNAL POWER PEDESTAL E ABBREVIATIONS CONDUITS AWG # TERMINATION 1 2 3 4 5 6 AsA8^9 CATSE 4 PAIR 1 1 1 POLE F1 CAT5E "ED 4 PAIR 1 1 1 POLE F2 CAT5E GELD 4 PAIR POLE F3 CAT5E St"E!A 4 PAIR 1 1 1 1 POLE F1 CAT5E St11EtD 1 1 1 4 PAIR POLE F4 RD (+) #14 ORWM c+) 1 1 1 1 1 2 2 ENCLQSU REDX srnEtn CAT5E 4 PAIR 1 1 1 POLE M 1 CATSE"ELD 4 PAIR 1 1 1 1 POLE M2 CAT5E 4P R 1 1 1 1 1 POLE M2 #1QMIRE{-� 2 2 2 POLE M1 euac+, #10 wHRE 2 2 2 2 POLE M2 etAac+� #102 �_� 2 2 POLE F4 #10 VWE 2 2 POLE F2 evac+� #10 rliffE 2 2 2 2 POLE F3 4410 m" CAT5 DLC TSP LED R/W PDP STP = CATEGORY FIVE CABLE = DETECTOR LOOP CABLE (SHIELDED) = TWISTED SHIELDED PAIR = LIGHT EMITTING DIODE = RIGHT OF WAY = POWER DISTRIBUTION PANEL = SLIMLINE TERMINATION PANEL 3 SOURCE I � It i 0 20' POLE SCHEDULE ' SCALE: 1 "=20' I NO. TYPE HEIGHT NEW/ EXISTING M@1 REDFLEX, TYPE 1 14' N £ REDFLEX, TYPE 1 14' N F1 REDFLEX, TYPE 1 10' N 1 REDFLEX, TYPE 1 10' N F3 REDFLEX, TYPE 1 10' N POLE M2 REDFLEX, TYPE 1 10' N X1 TRAFFIC SIGNAL 30' E I TRAFFIC SIGNAL POLE M2 r� 1, 5'-0" F.O.C. REDFLEX GK1 3—CAMERA SYSTEM W/250 WATT FLASH BA -COST -01 (35.354793, —119.092474) 0 1 2 3 8 9 1011121617 REDFLEX SLIMLINE CAMERA ENCLOSURE W/500 WATT FLASH AND STP BA -COST -04A 13 F4 6 8 1 11217 ,�, _. S �_. ___ GAS__ ___ GAS p. CABLE STnr.K)AI F HWY I m 0 MAPPING RADAR DEVICE _ -6N INSTALLED ON (MAST ARM OF SIGNAL POLE X1 7 13 5 REDFLEX DUAL CAMERA SETUP W/PDP & STP; TWO SLIMLINE CAMERA ENCLOSURES, ONE 500 WATT FLASH AND AN 8—PORT SWITCH BA -COST -02 Cam= SIGNAL POWER PEDESTAL E CONDUCTORS CONDUITS AWG # TERMINATION 1 2 3 4 5 6 AsA8^9 CATSE 4 PAIR 1 1 1 POLE F1 CAT5E "ED 4 PAIR 1 1 1 POLE F2 CAT5E GELD 4 PAIR POLE F3 CAT5E St"E!A 4 PAIR 1 1 1 1 POLE F1 CAT5E St11EtD 1 1 1 4 PAIR POLE F4 RD (+) #14 ORWM c+) 1 1 1 1 1 2 2 ENCLQSU REDX srnEtn CAT5E 4 PAIR 1 1 1 POLE M 1 CATSE"ELD 4 PAIR 1 1 1 1 POLE M2 CAT5E 4P R 1 1 1 1 1 POLE M2 #1QMIRE{-� 2 2 2 POLE M1 euac+, #10 wHRE 2 2 2 2 POLE M2 etAac+� #102 �_� 2 2 POLE F4 #10 VWE 2 2 POLE F2 evac+� #10 rliffE 2 2 2 2 POLE F3 4410 m" POLES 3 SOURCE I � It i 0 20' I y ' SCALE: 1 "=20' I � I i I 3 0 8 I IEI FF l I POLE M 1D 1 1 ENCLOSURE W/500 WATT £ f � I I F3 8 1 1121718 POLE F1 f ' 1 1 t ! INSTALLED ON MAST I zz I i m m I- I POLE M2 z m NOTE: LOCATION OF SIGNAL EQUIPMENT IS BASED UPON LOCATIONS "7�7 i f PRIOR TO WESTBOUND RIGHT 1 1 I I E POLE M2 r� d- p +a ab f t £ I 55 S 1 ; 1 Uj }a o POLE F1 £ 3 la 1 ,. E 1 RED PHASE (5-7 CABLE CONDUCTOR) 1 co 0 zo e 1 I I I MAPPING RADAR DEVICE (POLE X 1) 1 I 1 obi 1j y MAPPING RADAR DEVICE (POLE X2) I s 1 1 POLE Ml (COMMS) 1 1 POWER CIRCUIT 1 (PDP POLE F1) 2 2 POWER CIRCUIT 2 (PDP POLE F1) 2 2 POWER CIRCUIT 3 (PMC POLE Ml) 2 2 POWER CIRCUIT 4 (PMC POLE M2) 2 2 POWER CIRCUIT 5 (PMC POLE M2) 2 2 POWER CIRCUIT 6 1, 5'-0" F.O.C. REDFLEX GK1 3—CAMERA SYSTEM W/250 WATT FLASH BA -COST -01 (35.354793, —119.092474) 0 1 2 3 8 9 1011121617 REDFLEX SLIMLINE CAMERA ENCLOSURE W/500 WATT FLASH AND STP BA -COST -04A 13 F4 6 8 1 11217 ,�, _. S �_. ___ GAS__ ___ GAS p. CABLE STnr.K)AI F HWY I m 0 MAPPING RADAR DEVICE _ -6N INSTALLED ON (MAST ARM OF SIGNAL POLE X1 7 13 5 REDFLEX DUAL CAMERA SETUP W/PDP & STP; TWO SLIMLINE CAMERA ENCLOSURES, ONE 500 WATT FLASH AND AN 8—PORT SWITCH BA -COST -02 Cam= SIGNAL POWER PEDESTAL E 2 Idn E I �o I i £ � I 3 I I I10' I � It i 0 20' I y ' SCALE: 1 "=20' I � I i I 3 0 8 I IEI FF l I £ I f ENCLOSURE W/500 WATT £ f � I I F3 8 1 1121718 f ' E 13 MAPPING RADAR DEVICE t ! INSTALLED ON MAST I zz I i m m I- I z rel z m NOTE: LOCATION OF SIGNAL EQUIPMENT IS BASED UPON LOCATIONS "7�7 i f PRIOR TO WESTBOUND RIGHT £ y� � TURN �4 "" '� '� ADDITION. TO BE FIELD VERIFIED. I I E I r� d- p +a ab f t £ I 55 S £ ; Lu Uj }a o S £ 3 la L 9 14 7� A E � �wbwn. _. t. _ 4D, Lo Ui, 7 rr' '-6" II .O.C. r (ISTING° TRAFFIC 0 BINET a{ V) 0 I t { f I i }j P i E I £ 2 Idn E I �o I i £ � I £ I I I10' I � It i 0 20' I y ' SCALE: 1 "=20' I � I i I 3 0 8 I IEI FF l I REDFLEX SLIMLINE CAMERA I f ENCLOSURE W/500 WATT t FLASH AND STP BA -COST -04 F3 8 1 1121718 E 13 MAPPING RADAR DEVICE t ! INSTALLED ON MAST I ARM OF SIGNAL POLE 6 NOTE: LOCATION OF SIGNAL EQUIPMENT IS BASED UPON LOCATIONS "7�7 4 LO PRIOR TO WESTBOUND RIGHT AS� y� � TURN �4 "" '� '� ADDITION. TO BE FIELD VERIFIED. I 14 r� d- p +a ab f t £ I 55 S Lij LiJ Lu 1 z LTJ ----------------- £ I < ,. E E 4-- E _ E _ _ _ E E�_ co 0 zo e #= I I I I I obi 1j y I s - _ 15 v O�ATI UNE I REDFLEX SLIMLINE CAMERA ENCLOSURE W/500 WATT FLASH AND STP BA -COST -02A F2 6 8 111217 —REDFLEX GK1 3—CAMERA SYSTEM W/250 WATT FLASH IBA -COST -03 (35.353935, —119.092094) RiMmm©m ommmmi 2'-6„ wi, (PDP) wHRE POLE F1 2 �4 1_7 f UST VERIFY EXISTING UTILITY INFO AND LOCATION CITY/STATE POWER j_+ . . SOURCE (120V) # cRourJD� 3 3 3 "r l 8 w"'� REDFLEX PDP 3 GENERAL NOTES .- STRANDED BOND #8+ 1 1 1 1 1 1 1 1 1 1 1 ALL REDFLEX 1 1 1 1 1 1 1. ALL EXISTING UTILITIES L TIES SHOWN WITHIN THE PLANS ARE PROVIDED BY THE BEST AVAILABLE INFORMATION PROVIDED BY COOPERATING UTILITY COMPANIES. NEITHER REDFLEX NOR THE CITY ASSUME RESPONSIBILITY AS TO THE TOTAL NEW CABLES 9 3 4 8 12 1 7 7 12 3 5 5 4 1 5 2 PRECISE LOCATION OR ACCURACY OF SHOWN UTILITIES. THE CONTRACTOR SHALL PROPERLY FIELD VERIFY UTILITY LOCATIONS AND SHALL PROPERLY PROTECT, MAINTAIN AND/OR REPAIR ANY 12 12 4 1 12 4 4 1 EXPOSED UNKNOWN UTILITIES SHOWN WITHIN THE PLANS. REDFLEX AND THE CIT`( ASSUME NO LIABILITY RESULTING IN POSSIBLE DEFICIENCIES IN UTILITY LOCATIONS AND NO REMEDIAL OR ADDITIONALAGE COMPENSAFALL OTIONAWI ANY NOTE: ALLOWED. L BE CONDUIT SIZE (INCHES) 3 — 2 — 2 — — — 3 2 — — 2 _ _ _ 2(2'°) CONDUITS CONDUIT LENGTH (- FEET) 72 8 19 156 6 3 41 62 91 12 139 11 6 3 5 4 MAY BE 14 14 10 30 10 10 10 2. ALL WORK SHALL CONFORM TO ALL NATIONAL BUILDING AND ELECTRICAL CODES EXCEPT WHEN THE STATE D.O.T. AND THE CITY STAND SUBSTITUTED 30 /OR ARDS SUPERSEDE. NEW/EXISTING CONDUIT N E :N] E N E E E N N E E N EtE E FOR THE 4" N N N E =NN N JE 3• ALL SUBSTRUCTURES MUST BE LOCATED PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL AND MUST NOTIFY ALL UTILITY * = CONDUTORS RUN WITHIN POLE I A = AFRIAI RI IM THE CONTRACTOR AND CITY OFFICIALS TO MARK THE EXACT LOCATION OF REDFLEX EQUIPMENT IF NECESSARY PRIOR TO CONST COMPANIES WITHIN A MINIMUM OF 48 HOURS PRIOR TO START OF WORK. REDFLEX WILL MEET WITH VER DATE INITIAL REVISIONS (YYMMDD) I I DESCRIPTION AutoCAD Teff0ato 2012-01-01 ws RUCTION. 4. TRAFFIC FLOW SHALL BE MAINTAINED AT ALL TIMES. TEMPORARY SHUTDOWNS OR DISRUPTION MUST BE COORDINATED WITH THE CITY. REDFLEXIG SNATU BY: APPROVED DRAWN BY: REDFLEitJ-LORD CITY OF: BAKERSFIELD' CA DRAWING NO. DESSIGNEIGNED BY: 10 71 TRAFFIC SYSTEMS J.FREY PUBLIC WORKS DIRECTOR / CITY ENGINEER DATE REDLIGHT PHOTO ENFORCEMENT INTERNAL REVIEW CHECKED BY: 23751 NORTH 23RD AVE RECOMMENDED BY: RECOMMENDED BY: -118 COFFEE PHOENIX, AZ 85085 AS -BUILT, VERIFIED BY: C C C PH: 623-207-2000 f (- C RD AT STOCKDALE HWY SIZE SHEET NO., INSTALLATION CONSTRUCTION DEPUTY CITY ENGINEER DEVELOPMENT SERVICES D i � 3 o o I 3 0 8 I IEI FF l I 0 I f I IE E IA E I I oCV, £ IQ F £ F£ ( £ r� d- L0 Lij LiJ Lu W LTJ i t E 3 I REDFLEX SLIMLINE CAMERA ENCLOSURE W/500 WATT FLASH AND STP BA -COST -02A F2 6 8 111217 —REDFLEX GK1 3—CAMERA SYSTEM W/250 WATT FLASH IBA -COST -03 (35.353935, —119.092094) RiMmm©m ommmmi 2'-6„ wi, (PDP) wHRE POLE F1 2 �4 1_7 f UST VERIFY EXISTING UTILITY INFO AND LOCATION CITY/STATE POWER j_+ . . SOURCE (120V) # cRourJD� 3 3 3 "r l 8 w"'� REDFLEX PDP 3 GENERAL NOTES .- STRANDED BOND #8+ 1 1 1 1 1 1 1 1 1 1 1 ALL REDFLEX 1 1 1 1 1 1 1. ALL EXISTING UTILITIES L TIES SHOWN WITHIN THE PLANS ARE PROVIDED BY THE BEST AVAILABLE INFORMATION PROVIDED BY COOPERATING UTILITY COMPANIES. NEITHER REDFLEX NOR THE CITY ASSUME RESPONSIBILITY AS TO THE TOTAL NEW CABLES 9 3 4 8 12 1 7 7 12 3 5 5 4 1 5 2 PRECISE LOCATION OR ACCURACY OF SHOWN UTILITIES. THE CONTRACTOR SHALL PROPERLY FIELD VERIFY UTILITY LOCATIONS AND SHALL PROPERLY PROTECT, MAINTAIN AND/OR REPAIR ANY 12 12 4 1 12 4 4 1 EXPOSED UNKNOWN UTILITIES SHOWN WITHIN THE PLANS. REDFLEX AND THE CIT`( ASSUME NO LIABILITY RESULTING IN POSSIBLE DEFICIENCIES IN UTILITY LOCATIONS AND NO REMEDIAL OR ADDITIONALAGE COMPENSAFALL OTIONAWI ANY NOTE: ALLOWED. L BE CONDUIT SIZE (INCHES) 3 — 2 — 2 — — — 3 2 — — 2 _ _ _ 2(2'°) CONDUITS CONDUIT LENGTH (- FEET) 72 8 19 156 6 3 41 62 91 12 139 11 6 3 5 4 MAY BE 14 14 10 30 10 10 10 2. ALL WORK SHALL CONFORM TO ALL NATIONAL BUILDING AND ELECTRICAL CODES EXCEPT WHEN THE STATE D.O.T. AND THE CITY STAND SUBSTITUTED 30 /OR ARDS SUPERSEDE. NEW/EXISTING CONDUIT N E :N] E N E E E N N E E N EtE E FOR THE 4" N N N E =NN N JE 3• ALL SUBSTRUCTURES MUST BE LOCATED PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL AND MUST NOTIFY ALL UTILITY * = CONDUTORS RUN WITHIN POLE I A = AFRIAI RI IM THE CONTRACTOR AND CITY OFFICIALS TO MARK THE EXACT LOCATION OF REDFLEX EQUIPMENT IF NECESSARY PRIOR TO CONST COMPANIES WITHIN A MINIMUM OF 48 HOURS PRIOR TO START OF WORK. REDFLEX WILL MEET WITH VER DATE INITIAL REVISIONS (YYMMDD) I I DESCRIPTION AutoCAD Teff0ato 2012-01-01 ws RUCTION. 4. TRAFFIC FLOW SHALL BE MAINTAINED AT ALL TIMES. TEMPORARY SHUTDOWNS OR DISRUPTION MUST BE COORDINATED WITH THE CITY. REDFLEXIG SNATU BY: APPROVED DRAWN BY: REDFLEitJ-LORD CITY OF: BAKERSFIELD' CA DRAWING NO. DESSIGNEIGNED BY: 10 71 TRAFFIC SYSTEMS J.FREY PUBLIC WORKS DIRECTOR / CITY ENGINEER DATE REDLIGHT PHOTO ENFORCEMENT INTERNAL REVIEW CHECKED BY: 23751 NORTH 23RD AVE RECOMMENDED BY: RECOMMENDED BY: -118 COFFEE PHOENIX, AZ 85085 AS -BUILT, VERIFIED BY: C C C PH: 623-207-2000 f (- C RD AT STOCKDALE HWY SIZE SHEET NO., INSTALLATION CONSTRUCTION DEPUTY CITY ENGINEER DEVELOPMENT SERVICES D CONSTRUCTION NOTES 0 THIS IS A GK1 SYSTEM. ALL CONDUCTOR CONNECTIONS TO BE MADE WITHIN THE MAIN SCENE CAMERA ENCLOSURE AND INSIDE THE POLE MOUNTED CABINET THAT WILL BE INSTALLED BY THE CONTRACTOR, SEE POLE DETAILS. F2-1 CONTRACTOR SHALL TERMINATE AND LAND ALL POWER CIRCUITS INTO REDFLEX POWER DISTRIBUTION PANEL. 173-1 INSTALL INLINE FUSE HOLDER (#HEB–AA) ON RED PHASE CONDUCTOR WITH 5 AMP FUSE (#MEN -10) INSIDE CITY CABINET AND REDFLEX ENCLOSURE TO PROTECT EQUIPMENT. TERMINATE #14 WIRE TO RED PHASE AND NEUTRAL INSIDE CITY TRAFFIC CABINET. SEE CONDUCTOR SCHEDULE FOR APPROACHES. (NOTE: NOTIFY THE TRAFFIC OPERATIONS DEPARTMENT OF THE CITY 24 HOURS BEFORE CONNECTION). ® INSTALL A 40 AMP CIRCUIT BREAKER INTO POWER PANEL FOR 120V SUPPLY TO REDFLEX POWER DISTRIBUTION PANEL. F5 INSTALL TWO SLIMLINE CAMERA ENCLOSURES, ONE 500 WATT FLASH ON REDFLEX POLE, ONE SLIMLINE TERMINATION PANEL TO BE INSTALLED BY THE CONTRACTOR, SEE POLE DETAILS; AIM AT MONITORED APPROACHES. ® INSTALL SLIMLINE CAMERA ENCLOSURE AND 500 WATT FLASH ON REDFLEX POLE, SLIMLINE TERMINATION PANEL TO BE INSTALLED BY THE CONTRACTOR, SEE POLE DETAILS; AIM AT MONITORED APPROACHES. M ATTACH MAPPING RADAR DEVICE TO MAST ARM OF SIGNAL POLE. RUN CAT5E CABLE FROM MAPPING RADAR DEVICE TO REDFLEX CAMERA ENCLOSURE. MAPPING RADAR DEVICE TO MONITOR SOUTHBOUND LANES 1-6 AND NORTHBOUND LANES 1-6. ® INSTALL FOUNDATION, POLE AND GROUND FOR REDFLEX EQUIPMENT, SEE DRAWING FOR LOCATION. SEE POLE DETAIL. ® INSTALL CAMERA ENCLOSURE ON REDFLEX POLE; AIM AT MONITORED APPROACHES. 10 INSTALL A FLASH UNIT ON REDFLEX POLE, AIM AT MONITORED APPROACHES. 11 CONNECT POLE TO STRANDED BOND GROUND AND GROUNDING ROD IN POLE FOUNDATION AND TO SYSTEM GROUND BONDED BACK AT THE REDFLEX ENCLOSURE. CONTRACTOR SHALL PERFORM THREE–POINT GROUND TEST AT EACH MAIN CABINET OR ENCLOSURE. GROUNDING SYSTEM MUST YIELD RESULTS BELOW 10 OHMS AND DOCUMENTATION FROM THE ELECTRICAL CONTRACTOR MUST BE PROVIDED TO REDFLEX. NO ADDITIVE IS TO BE PUT IN THE GROUND TO ARTIFICIALLY YIELD THE DESIRED RESULTS. 12 PULL ROPE TO BE RUN THROUGH ALL CONDUIT FROM THE REDFLEX ENCLOSURE TO ALL REDFLEX EQUIPMENT. ALL SPARE CONDUCTORS/WIRES SHALL TERMINATE AT THE JUNCTION BOXES, CAMERA ENCLOSURES AND CABINETS. SPARE WIRES SHALL BE TAPED AT THE END, CONTINUOUS IN LENGTH AND IDENTIFIABLE WITH PERMANENT IDENTIFICATION BAND AND TAGGED AS "RTS". 13 CONTRACTOR SHALL COMPLETE AS MANY POTHOLES AS NECESSARY. CONDUIT TO BE BORED OR TRENCHED TO MIN. STANDARD COVER DEPTH REQUIRED BY THE CITY (24" MINIMUM). 14 VERIFY IF EXISTING SIGNAL HEADS HAVE LED'S INSTALLED. IF NOT, INSTALL RED AND AMBER GELCORE LED'S OF THE TYPE APPROVED BY THE CITY–VERIFY BEFORE INSTALLING. IF NEEDED, ADJUST REDFLEX CAMERA SO IT IS VISIBLE TO THE SIGNAL HEADS. 15 CITY TO REFRESH STRIPING (VIOLATION LINE AND LANES ETC) AS NEEDED AT THE MONITORED APPROACHES. 16 INSTALL WIRELESS COMMUNICATIONS INTO PMC. 17 TERMINATE POLE TO REDFLEX POWER CIRCUIT, SEE CONDUCTOR SCHEDULE FOR DETAILS (HOT AND NEUTRAL). 18 INSTALL TWO SLIMLINE CAMERA ENCLOSURES, ONE 500 WATT FLASH ON REDFLEX POLE AND AN 8–PORT SWITCH, SEE POLE DETAILS; AIM AT MONITORED APPROACHES. CONDUCTORS CONDUITS TYPE POLES EXISTING MO TERMINATION 14' N l@ REDFLEX, TYPE 1 d N F1 I 10' MING AVE I } N F�3 L ___ 10' N I ri I 1 REDFLEX, TYPE 1 10' N X1 TRAFFIC SIGNAL 30' E I E TRAFFIC SIGNAL 30' E m 0 7_ W13 WB SOURCE AWG# 1 2 3 lAsA5A6A7A8 TIO I LINE AAAAAAAAAAAAAA Q F1 X1 POLE F1 CAT5E � R 1 1 1 1 1 1 1 1 POLE F4 1 1 POLE M1 CAT5E ; EU 1 1 1 1 1 1 1 1 1 POLE F1 1 1 POLE F1 CAT5E smw 1 1 1 POLE F2 1 1 4 POLE M2 CAT5E 1 1 1 1 1 1 POLE F3 1 1 4 PAIR POLE M2 CAT5E SMELD 1 1 1 POLE F1 1 1 RED PHASE (5-7 #14 RED (+) 1 1 1 1 1 1 1 2 1 1 1 2 REDFLEX 1 1 CABLE CONDUCTOR) DRAIN (+) ENCLOSURES MAPPING RADAR DEVICE (POLE X1) CAT5E SWELD 4PAIR 1 1 1 1 1 1 1 1 1 POLE Ml 1 1 MAPPING RADAR DEVICE (POLE X2) CAT5E SHELD 4 PAIR 1 1 1 1 1 1 POLE M2 1 1 POWER CIRCUIT 1 (PDP POLE F1) #10`+> 2 2 2 2 2 2 2 2 2 POLE M1 2 2 POWER CIRCUIT 2 (PDP POLE F1) #10 B` c+> OWE 2 2 2 2 POLE M2 2 2 POWER CIRCUIT 3 (PMC POLE M1) #10 '(+) Vim c—i 2 2 2 POLE F4 2 2 POWER CIRCUIT 4 (PMC POLE M2) #10 a` M W+1rrE 2 2 2 POLE F2 2 2 POWER CIRCUIT 5 (PMC POLE M2) #10"+� IME 2 2 2 2 2 2 POLE F3 2 2 CIRCUIT 6 #10 BLACK{ WHffE POLE F1 2 (PDP}R CITY/STATE POWER#8 SOURCE (120V) BLACK 3 3 REDFLEX PDP 3 STRANDED BOND #8 GLEN 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ALL REDFLEX EQUIPMENT 1 1 1 1 1 1 TOTAL NEW CABLES 9 9 4 8 8 8 8 8 12 12 1 7 12 12 4 5 5 5 4 1 2 3 9 14 4 1 12 4 4 1 NOTE: 2(2") CONDUIT SIZE (INCHES) 3 — 2 — — — — — — 2 — — — 3 2 — — — 2 — — — CONDUITS MAY BE SUBSTITUTED FOR THE 4" CONDUIT LENGTH (- FEET) 24 56 9 35 6 51 74 43 6 5 13 113 46 29 21 30 122 32 3 4 2 5 10 14 14 30 10 10 10 30 NEW/EXISTING CONDUIT N E N E E E E E E N E E E N N E E El N E E E N N N E N T N N E LEGEND CM TRAFFIC CONTROL CABINET 0 POWER CABINET GK1 CAMERA SYSTEM WITH FLASH 13 SLIMLINE CAMERA W/FLASH ® NEW PULL/JUNCTION BOX o EXISTING PULL/JUNCTION BOX DT TELECOMMUNICATIONS LUMINAIRE REDFLEX MAPPING RADAR ABBREVIATIONS CATS = CATEGORY FIVE CABLE DLC = DETECTOR LOOP CABLE (SHIELDED) TSP = TWISTED SHIELDED PAIR LED = LIGHT EMITTING DIODE R/W = RIGHT OF WAY PDP = POWER DISTRIBUTION PANEL STP = SLIMLINE TERMINATION PANEL F REDFLEX GK1 3—CAMERA SYSTEM W/250 WATT FLASH BA-ORMI-01 (35.340240, —119.114542) Cl 2389 10111217 REDFLEX SLIMLINE CAMERA ENCLOSURE W/500 WATT FLASH \\\ AND STP BA-ORMI-04A F4 6 8 111217 — E i £ m� ___—......__...._� £ MAPPING RADAR DEVICE---,_ INSTALLED ON MAST ARM OF SIGNAL POLE X1 7 REDFLEX DUAL CAMERA SETUP W/PDP & STP; TWO SLIMLINE CAMERA ENCLOSURES, ONE 500 WATT FLASH AND A 8—PORT SWITCH BA-ORMI-02 F1 8 11121718 SIGNAL POWER PEDESTAL EXISTING TRAFFIC CABINET ❑3 POLE SCHEDULE NO. TYPE HEIGHT EXISTING MO REDFLEX, TYPE 1 14' N l@ REDFLEX, TYPE 1 d N F1 I 10' MING AVE I } N F�3 L ___ 10' — E i £ m� ___—......__...._� £ MAPPING RADAR DEVICE---,_ INSTALLED ON MAST ARM OF SIGNAL POLE X1 7 REDFLEX DUAL CAMERA SETUP W/PDP & STP; TWO SLIMLINE CAMERA ENCLOSURES, ONE 500 WATT FLASH AND A 8—PORT SWITCH BA-ORMI-02 F1 8 11121718 SIGNAL POWER PEDESTAL EXISTING TRAFFIC CABINET ❑3 POLE SCHEDULE NO. TYPE HEIGHT EXISTING MO REDFLEX, TYPE 1 14' N l@ REDFLEX, TYPE 1 14' N F1 REDFLEX, TYPE 1 10' N m REDFLEX, TYPE 1 10' N F�3 REDFLEX, TYPE 1 10' N I ri I 1 REDFLEX, TYPE 1 10' N X1 TRAFFIC SIGNAL 30' E I E TRAFFIC SIGNAL 30' E I I 5'-0" i F.O.0. i I c I r iW £ REVISIONS £ £ £ I I ; £ I BAKERSFIELD, I D= } E I ; € ID ml m m rel m I REDLIGHT PHOTO ENFORCEMENT JL INITIAL EMAINECAMERA PUBLIC WORKS DIRECTOR j CITY ENGINEER DATE 2 150612 JL UPDATED150511 CALLOUTS I ri I 1 — E OLD RIVER RD AT MING AVE i £ RECOMMENDED BY: E I I 1 I E 2 ERFVERIFIED BY: INSTALLATION CONSTRUCTION I 0 m 0 7_ W13 WB — DEPUTY CITY ENGINEER DEVELOPMENT SERVICES E 15 VIO, TIO I LINE J,v, 0- C) i r L0 v 10' 0 20' SCALE: 1 "=20' REDFLEX DUAL CAMERA SETUP; TWO SLIMLINE CAMERA ENCLOSURES, ONE 500 WATT FLASH AND ONE STP w:� i' i2 ©um®®' MAPPING RADAR DEVICE INSTALLED ON MAST ARM OF SIGNAL POLE I. R/W R/w q.......,,.m»...e.e.�.e.e........,..... ....v,'., �......w..m...w.e.m... a� E i 3 3 — I fi 7t 1 m Is 2'-6„ F.O.C. 2'=6" IF.O.C. GAS GAS GAS REDFLEX SLIMLINE CAMERA 13 ENCLOSURE W/500 WATT FLASH AND STP I BA-ORMI-02A F2 6 8 111217 REDFLEX GK1 3—CAMERA i SYSTEM W/250 WATT FLASH { r1lBA-ORMI-03 (35.339361, —119.114124) I 9 i MUST VERIFY EXISTING UTILITY INFO AND LOCATION GENERAL NOTES 1. ALL EXISTING UTILITIES SHOWN WITHIN THE PLANS ARE PROVIDED BY THE BEST AVAILABLE INFORMATION PROVIDED BY COOPERATING UTILITY COMPANIES. NEITHER REDFLEX NOR THE CITY ASSUME RESPONSIBILITY AS TO THE PRECISE LOCATION OR ACCURACY OF SHOWN UTILITIES. THE CONTRACTOR SHALL PROPERLY FIELD VERIFY UTILITY LOCATIONS AND SHALL PROPERLY PROTECT, MAINTAIN AND/OR REPAIR ANY DAMAGE OF ALL KNOWN AND ANY EXPOSED UNKNOWN UTILITIES SHOWN WITHIN THE PLANS. REDFLEX AND THE CITY ASSUME NO LIABILITY RESULTING IN POSSIBLE DEFICIENCIES IN UTILITY LOCATIONS AND NO REMEDIAL OR ADDITIONAL COMPENSATION WILL BE ALLOWED, 2. ALL WORK SHALL CONFORM TO ALL NATIONAL BUILDING AND ELECTRICAL CODES EXCEPT WHEN THE STATE D.O.T. AND/OR THE CITY STANDARDS SUPERSEDE. 3. ALL SUBSTRUCTURES MUST BE LOCATED PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL AND MUST NOTIFY ALL UTILITY COMPANIES WITHIN A MINIMUM OF 48 HOURS PRIOR TO START OF WORK. REDFLEX WILL MEET WITH THE CONTRACTOR AND CITY OFFICIALS TO MARK THE EXACT LOCATION OF REDFLEX EQUIPMENT IF NECESSARY PRIOR TO CONSTRUCTION. * = CONDUTORS RUN WITHIN POLE I A = AERIAL RUN 4. TRAFFIC FLOW SHALL BE MAINTAINED AT ALL TIMES. TEMPORARY SHUTDOWNS OR DISRUPTION MUST BE COORDINATED WITH THE CITY. REVISIONS RELAY SCHEDULE ,g REDFLE T FFIG* SYSTEMS 23751 NORTH 23RD AVE $ �$ PHOENIX, AZ 85085 PH: 623-207-2000 REDFLEX SIGNATURE °�®"�®Y' APPROVED BY: CITY OF: BAKERSFIELD, CA DRAWING N0. 7 — 119 DATE VER (YY ATE INITIAL DESCRIPTION NB 2 DESIGNED BY: J.FREY REDLIGHT PHOTO ENFORCEMENT JL INITIAL EMAINECAMERA PUBLIC WORKS DIRECTOR j CITY ENGINEER DATE 2 150612 JL UPDATED150511 CALLOUTS EB — INTERNAL REVIEW CHECKED BY: OLD RIVER RD AT MING AVE RECOMMENDED BY: RECOMMENDED BY: S13 2 ERFVERIFIED BY: INSTALLATION CONSTRUCTION SIZE D SHEET N0. W13 WB — DEPUTY CITY ENGINEER DEVELOPMENT SERVICES AutoCAD TmOcts 2012-01-01 ,.�