Loading...
HomeMy WebLinkAbout1.8-6758 Ph 4E C 1 2 3 LOT LINE LOT LINE l'-6"1 - — - w GSTC STUB - IL IL — —1 — �—L-H — — — R/W NFT WATER METER I MAIN TRENCH O o I (o — —-- R/W w a o LOT LINE I _ f� V-6" TYPICAL INTERIOR STUB INSTALLATION 24" NIDE (COMMON) I r FINISH GRADE 30" MINIMUM IN FRANCHISE AREA 30" MINIMUM IN :. FRANCHISE AREA 12" SANDif ' 12 OVER TELE II MIN 2" OR 4".'. C.:C : `.. :: '„ POSSIBLE 62" 12" MIN. 2" OR 4' 3MIN." ; El MIN. 2" or 4" SHADING 1) 2" SAND SHADING AROUND GAS & ELECTRIC IF SOIL IS NOT ROCK FREE 2) ONLY PARTIES PARTICIPATING IN U.S.A. ARE ALLOWED IN JOINT TRENCH 3) ANY PARTY EXCEEDING ITS TRENCH ALLOTMENT SHALL MAKE ARRANGEMENTS TO ENSURE THAT TRENCH WILL ACCOMMODATE ADDED FACILITIES 4) GAS TO GO ON SIDE OF TRENCH NEAREST STREET 5) TRENCH LAYOUT SHALL CONFORM TO UO STANDARD S5453. TYPICAL DISTRIBUTION TRENCH NOTE: ALL SERVICES AND SUB -STRUCTURES ARE NOT TO SCALE FOR CLARITY. ALL COMPONENTS SHALL FIT WITHIN THE PUE OR FRANCHISE AREA UNLESS OTHERWISE NOTED. REFER TO DETAILS FOR LOCATIONS. 1 SUBSTRUCTURE VERIFICATION STAMP DEVELOPER PLEASE NOTE AND SIGN ALL P.G.& E. ENCLOSURES AND BOXES HAVE BEEN SET TO GRADE ACCORDING TO GRADE STAKES PROVIDED BY DEVELOPERS ENGINEER. ALL COSTS TO RELOCATE OR RE -ADJUST BOXES AT A LATER DATE WILL BE BILLED TO THE DEVELOPER. PLEASE HAVE YOUR JOB SUP. VERIFY THE CORRECTED GRADE OF ALL ENCLOSURES AND BOXES. AND SIGN AND DATE DRAWING. THANK YOU SIGNED DATE NO SCALE NO SCALE 4 � 5 18' MIN FINISH GRADE 24" MIN. 59-1/2" MIN. T T C C 6" PMIN. 000 1) 2” SAND SHADING AROUND GAS & ELECTRIC IF NATIVE SOIL IS NOT ROCK FREE. 2) SEE OTHER DETAIL IF NON -PG&E STREETLIGHT IS IN TRENCH 3) ONLY PARTIES PARTICIPATING IN U.S.A. ARE ALLOWED IN THIS TRENCH 2" MIN. 2" MIN. 2' SHADING TYPICAL SERVICE TRENCH NO SCALE 10' PUE 4'/6' PAD -MOUNTED / EQUIPMENT SUBSURFACE ENCLOSURE L w lo' z J of LLJ 1' w U TRENCH CENTERLINE TYPI CAL INTERIOR STREET NO SCALE O LLI 16' z J 11' w Z w U TRENCH CENTERLINE TAFT HIGHWAY NO SCALE 7 JOINT TRENCH RECAP TRENCH OCCUPANTS DISTRIBUTION OR SERVICE TRENCH SIZE DEPTH FOOTAGE BACKFILL SURFACE GSTC DIST 24" x 59" 486' SPREAD DIRT GPTC DIST 24" x 59" 312' SPREAD DIRT GPSTC DIST 24" x 59" 873' SPREAD DIRT SC DIST 24" x 59" 83' SPREAD DIRT P DIST 24" x 59" 1 150' SPREAD DIRT GSTC SERV FRANCH 18" x 46 362' SPREAD DIRT GSTC SERV PRIVATE 18" x 46" 1 210' ISPREAD [C] DIRT GSTC SERV COMPL. 18" x 46" 950' SPREAD DIRT S SERVICE 18" x 46" 10' SPREAD DIRT GAS NOTE: TRENCH DEPTH NOT TO EXCEED 5' UNLESS APPROVED BY PG&E INSPECTOR. IN NO CASE SHOULD PLASTIC GAS PIPE BE INSTALLED AT A DEPTH GREATER THAN 10' UNLESS APPROVED BY PG&E SENIOR GAS ENGINEER. FOR TRENCH INSPECTION CALL (559) 263-7312 ANY CHANGES TO THIS DESIGN MUST FIRST BE APPROVED BY PG&E. GAS ADE: DOMINIC OTHART PHONE: (661) 398-5817 NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL DRAWINGS FOR ELECTRIC FACILITY PLACEMENT, DETAILS, AND CLEARANCES. JOINT TRENCH COMPOSITE APPROVED BY: GAS ADE: ELECT ADE: DATE: E:3 9 � 10 GENERAL NOTES: DEVELOPER TO DO ALL TRENCHING, SHADING, AND BACKFILLING. PER UO STANDARD S-5453. 2. PHONE AND CABLE TV FACILITIES ARE SUBJECT TO CHANGE AT THE DISCRETION OF THOSE COMPANIES. :i. PADS, BOXES AND OTHER FACILITES AREOTOT SHOWN TO SCALE. 4. GAS AND ELECTRIC FACILITIES WILL REQUIRE SAND SHADING IF NATIVE SOIL IS NOT ROCK -FREE. PG&E WILL INSPECT BACKFILL MATERIAL. TEL AND/OR CATV MAY ALSO REQUIRE 12" OF SAND BACKFILL. 5. GROUND TO BE WITHIN .2 FT OF FINISH GRADE PRIOR TO TRENCHING. 6. GAS AND ELECTRIC FACILITES REQUIRE AT LEAST 3' OF SEPARATION (1' UNDISTURBED SOIL) FROM PARALLEL RUNS OF WATER, SEWER, OR STORM DRAIN. 7. PRE -CONSTRUCTION MEETING REQUIRED TWO WEEKS PRIOR TO THE START OF INSTALLATION. 8. CALL U.S.A. AT LEAST 48 HOURS PRIOR TO TRENCHING (DIAL 811) 9. PG&E WILL ASSIST IN LOCATING ENDS OF EXISTING GAS MAINS. 10.. DEVELOPER IS RESPONSIBLE FOR OBTAINING ENCROACHMENT PERMITS.. 11. STREETLIGHT LOCATIONS MAY HAVE CHANGED. REFER TO THE APPROVED STREETLIGHT IMPROVEMENT PLAN FOR STREETLIGHT INSTALLATION. 12. DEVELOPER SHALL CONTACT ALL INVOLVED PARTIES PRIOR TO MAKING ANY CHANGES FROM TF.IS DRAWING. 13. REFER TO EACH PARTY'S INSTALLATION INSTRUCTIONS FOR MORE PRECISE DESCRIPTION OF SUBSTRUCTURES AND OTHER REQUIREMENTS. LEGEND: O 00 CON rn co CV — ...... __... _ M MINWM SEPARATION AND CLEARANCE RSQVJREMENT ." (Inches) G GAS �> ¢� P ELECTRIC PRIMARY S ELECTRIC SECONDARY T TELEPHONE F (T£L£PrNONeI DUCT 12 C CABLE TV 12 1 / SLASH INDICATES CHANGE IN OCCUPANCY — — --- — — PROPOSED SERVICE TRENCH — — PROPOSED MAIN LINE TRENCH o EXISTING UNDERGROUND FACILITY SOURCES. NON -PG&E') �2] PROPOSED #2 (17" x 30" x 18") ELECTRIC SPLICE BOX '2_E] PROPOSED #2E (17" x 30" x 26") ELECTRIC SPICE BOX � 3] PROPOSED #3 (24" x 36" x 18") ELECTRIC SPLICE BOX �3E] PROPOSED #3E (24" x 36" x 26") ELECTRIC SPLICE BOX F-6] PROPOSED #6 (4' x 6'-6" x 5') SUB -SURFACE ENCLOSURE �T] PROPOSED TELEPHONE PEDESTAL\SPLICE BOX [C] PROPOSED CABLE SPLICE BOX LW PROPOSED PAD MOUNTED TRANSFORMER cPsrc 10' INDICATES TRENCH FOOTAGE & OCCUPANCY --- PROPOSED LS 2A STREET LIGHT LOCATION (SEE NOTE 11) ----�' PROPOSED SERVICE LOCATION AL'_ FIELD CHANGES REQUIRE PRIOR APPROVAL FROM: COMPANY TELEPHONE 1. LES INGLES P G & E (661) 398-3907 2. BRIAN FRANZ ATT (661) 631-3492 3. GREG EOFF BRIGHTHOUSE (661) 395-3351 Utility Standard 55453. "Joint Tronch Exh1c't B Es updated as tc c -n s' O 00 CON rn co CV — ...... __... _ M MINWM SEPARATION AND CLEARANCE RSQVJREMENT ." (Inches) Li C �> ¢� T I a5 _ Ln r- I SEE NOTES 4,7, & 13 CV F (T£L£PrNONeI DUCT 12 17 t T gElLEBM I PIRO& BURY 1': 12 1 _ CRGA 2 12 S� (ELECTRIC SECONDARY, _ -- 3 s _(ELECTRIC PRIMARY) 2 2„ . 3 St a (STREETLIGHT) 3 SEE NOTE 3 o FE* (FOREIGN ELECTRIC 1: 12 12 . SOURCES. NON -PG&E') SEE NOTE 5 "&1&t be ctnss"ved a `Ublify as d4nr ,:, ... .... y N 3 4, 6. 7- and 13 acre coca:=d m .1 Z 3::z McKEE RD. PROJECT SITE zc� D — rz w ZCD L,U C/) o a TAFT HWY NTS VICINITY MAP 6 5 4 3 0 z Q 0 LLJ p Q m w LL_ ~ O 0 L_ LL O Q m w O O cn 6 c\ v Z CSO O 00 CON rn co CV E o c. C m v Li �> ¢� — Ln r- CV ~ Imo% M w L_ c\ o c\ m Q c> y .1 Z 3::z m 0 O rn rn �o w > � w J U WP Z U -) I= IV 1- O Q =5 O O = m IY U U Z O V) El- Q Cn J 00 C-) co o Z O M rn Li m cD Z � N HLo w 0 E -+cm Y m E_ O r co X cn Q O U o Q rn cla N M ►� z ,o FI N 44 Y'. r�- —4 m z a O 0 ..0.4 U v Z CSO O 00 CON rn co CV E o c. C m v Li �> ¢� — _t— ~ z w Q Q c> y Z 3::z m 0 O rn rn �o w > � w J U WP Z J -) Q cn U O Q QCL. CC) o Q = m IY CL U U cl- w 0 Q Cn J 00 Cl- w r M E-+ Li m � Z = Q w 0 E -+cm Y m < O w Q Q cla M N O LL I Z U L, j 0 Cc a Q 0 Z 1 INCH 0 Z c� cn w z w Q Q z d. 3::z 0 �o � w J C -) Q cn U CC) o w O r— 0 J Cc NY J 00 Cl- w M E-+ Li � Z = Q w E -+cm Y m < O w Q 1 INCH 0 Z c� 1,k-ko-�'s�- f'h ILI PGE TO: SQUEEZE EXIST. 2" MAIN REMOVE: (1) 2" PLASTIC CAP INSTALL: (1) 2" ELECTROFUSION CODE: 02-1635 LOCATING WIRE PER GS&S A-90.2 TEXISTING 2• HP PL PROPOSED 2' HP PL ° I GAS TIE-IN DETAIL "A)) - NO SCALE C 1 LB. ANODE - CODE: 56-1494 1 " CTS CONSTAB BLIND -END CPLG CODE: 02-0083 T T LOCATING I WIRE / 2' / / MIN. I / 1" CTS CONSTAB I / BLIND -END CPLG / CODE: 02-0083 1" CTS CONSTAB THREE-WAY TEE CODE: 02-1145 I I- 1' CONSTAB COUPLING B I CODE: 02-1021 J a 1" SERIES 1100 EXCESS FLOW VALVE = 0 � CODE: 02-2918 > INSTALL EXCESS FLOW VALVES 8"-12" o U FROM SERVICE TEE, PER GSS oN A-93.3 PG 5 OF 9 1" CONSTAB COUPLING 0 < CODE: 02-1021 n. m 2" x 1" BRANCHING SADDLE PROPOSED 2" HP PL w CODE: 02-9792 CAL BRANCH STUB SERVICE TIE-IN DETAIL TYPI NO SCALE A NOTE: ALL SERVICES AND SUB -STRUCTURES ARE NOT TO SCALE FOR CLARITY. ALL COMPONENTS SHALL FIT WITHIN THE PUE OR FRANCHISE AREA UNLESS OTHERWISE NOTED. REFER TO DETAILS FOR LOCATIONS. 4 5 1 6 LOOP LOCATIONC IN BOX PER A - ETS STATION PER G.S. & S. 0-10 FIN. GRD. LOCATING MARE GAS MAIN ETS DETAIL_ NO SCALE 1 L.B. ANODE TEST AT 100-110 PSI FOR MINIMUM OF 5 MIN Pressure CODE: 56-1494 Initials Date of Test SITE 1 Cn Ln 1" CTS CONSTAB Q G.S.&S L-16 /o I..L 6" X 1000' ROLL BLIND -END CPLG TERA TAPE CODE: 37-9947 WARNING TAPE INSTALATION ZONE o T CODE: 02-0083 LOCATING Plastic Pipe Data Footage and Size / SDR / Wall Thickness WIRE Pipe Manufacture V, Date Manufactured 1* CONSTAB COUPLING ❑ PE 2406/2708 ❑ Other PE: Footage and Size CODE: 02-1021 SDR / Wall Thickness 2 Pipe Manufacture 1" SERIES 800 EXCESS FLOW VALVE Date Manufactured > a' ❑ PE 2406/2708 ❑ Other PE: CODE: 02-2917 Foreman LAN ID: Date: Foreman Signature: List all plastic pipe by footage, size, manufacture and date manufactured per Gas Design Standard A-93.1 INSTALL EXCESS FLOW VALVES 8"-12' D Q Ln FROM SERVICE TEE, PER GSS J a L A-93.3 PG 5 OF 9 t CL U 1" CONSTAB COUPLING H- I w CODE: 02-1021 w 0 U.1 = 2" x 1" BRANCHING SADDLE O 0 = CODE: 02-9792 O CL U ATTACH EFV. I.D. TAG TO PROPOSED 2" I HP PL STUB END USING THE LOC. WIRE. TYPICAL SINGLE STUB SERVICE TIE-IN DETAIL_ 00 NO SCALE 7 1 8 Plastic Pipe Data TEST AT 100-110 PSI FOR MINIMUM OF 5 MIN Pressure Duration Initials Date of Test SITE 1 Cn Ln WARNING TAPE Q G.S.&S L-16 /o I..L 6" X 1000' ROLL TERA TAPE CODE: 37-9947 WARNING TAPE INSTALATION ZONE o T N 1 Plastic Pipe Data Footage and Size / SDR / Wall Thickness Li l Z Pipe Manufacture V, Date Manufactured NTS ❑ PE 2406/2708 ❑ Other PE: Footage and Size / SDR / Wall Thickness O Pipe Manufacture Date Manufactured :M ❑ PE 2406/2708 ❑ Other PE: c- Foreman LAN ID: Date: Foreman Signature: List all plastic pipe by footage, size, manufacture and date manufactured per Gas Design Standard A-93.1 GASLINE CAUTION TAPE FINISH GRADE - L- Ln Lil Q SITE 1 Cn Ln WARNING TAPE Q G.S.&S L-16 /o I..L 6" X 1000' ROLL TERA TAPE CODE: 37-9947 WARNING TAPE INSTALATION ZONE o T N 1 m 1 G SII GAS PIPELINE ATTENTION FOREMAN PRIOR TO STARTING JOB, CONSULT AREA CORROSION MECHANIC FOR LOCATING WIRE INSTALLATION AND CATHODIC PRO- TECTION REQUIREMENTS CONTACT: SAM HENRY PHONE: 661-342-0855 NOTIFIED U.S.A. DATE: TICKET: BY: INSTALLATION TESTED OR INSPECTED AND NOTED ON DRAWING ALL CORROSION LEVELS SATISFACTORY PER PG&E GAS UTILITY STANDARD TD -4181S QUALIFIED EMPLOYEE DATE Corrosion mechanics signature is required when a CPA boundary is within the scope of the project 9 � 10 GAS NOTES: 1. DEVELOPER TO INSTALL ALL GAS PIPE. 2. DEVELOPER TO DO ALL TRENCHING, BACKFILLING AND COMPACTING. 3. REFER TO TRENCHING COMPOSITE DRAWING FOR PRECISE LOCATION OF TRENCH, TRENCHING DETAILS, SHADING AND OCCUPANCY. 4. GAS PIPE REQUIRES SAND SHADING IF NATIVE SOIL IS NOT ROCK -FREE. PG&E WILL INSPECT BACKFILL MATERIAL. 5. GROUND TO BE WITHIN .2 FT OF FINISH GRADE PRIOR TO INSTALLATION OF GAS PIPE. 6. GAS REQUIRES AT LEAST 3' OF SEPARATION (1' UNDISTURBED SOIL) FROM PARALLEL RUNS OF WATER, SEWER, OR STORM DRAIN. 7. PRE -CONSTRUCTION MEETING REQUIRED AT LEAST 2 WEEKS PRIOR TO START OF INSTALLATON. 8. CONSULT WITH PG&E REPRESENTATIVE PRIOR TO INSTALLING CONDUIT FOR GAS PIPE. 9. CONTACT PG&E REPRESENTATIVE PRIOR TO MAKING ANY CHANGES FROM THIS DRAWING. 10. ALL EXCESS FLOW VALVES TO BE PLACED 8"-12" FROM GAS MAIN. 11. CALL U.S.A. AT LEAST 48 HRS PRIOR TO TRENCHING (DIAL 811) CONTRACTOR CONSTRUCTION REFERENCES 1. REFER TO GAS STANDARDS A-90, A-93 & A-93.1 FOR TYPICAL DIRECT BURIAL PLASTIC GAS MAIN AND SERVICE INSTALLATION. 2. REFER TO GAS STANDARDS A-90, A-90.3 & A-93.1 FOR TYPICAL PLASTIC GAS MAIN AND SERVICE INSERT CONSTRUCTION. 3. REFER TO GAS STANDARDS A-90.2, 0-10, 0-13, 0-13.1, TD -41805 & TD -4181S FOR TYPICAL_ ANODE AND LOCATING WIRE INSTALLATION ON DIRECT BURIAL PLASTIC GAS MAIN AND SERVICES. 4. REFER TO GAS STANDARDS AND A-90 & A-91 FOR TYPICAL GAS SERVICE RISER INSTALLATION 5. REFER TO GAS STANDARD A-34 FOR TEST CRITERIA ON GAS MAIN AND SERVICES. 6. PACIFIC GAS AND ELECTRIC TO PERFORM ALL HOT TIE-INS AND PURGING OF GAS PIPING PER GAS STANDARD A-38 7. CONTRACTOR IS RESPONSIBLE FOR CROSSING EXISTING WATER, SEWER AND STORM DRAIN LINES, EITHER UNDER OR OVER, AS REQUIRED TO MEET P.G.&E. COVER AND CLEARANCE REQUIREMENTS. REFER TO UO STANDARD S5453. 8. THE LOCATION OF ALL EXISTING OR NEWLY INSTALLED WATER, SEWER, AND STORM DRAIN OR OTHER LINES, SHALL BE DETERMINED BY THE CONTRACTOR. THE CONTRACTOR SHALL NOT RELY ON PG&E TO LOCATE FACILITIES. (PG&E WILL LOCATE PG&E FACILITIES UPON PROPER USA NOTIFICATION). CALL USA AT 811. 9. THE CONTRACTOR WILL BE REQUIRED TO REMOVE AND REPLACE TRENCH SPOIL WITH SELECT BACKFILL AS REQUIRED BY PG&E SPECIFICATIONS, AND ANY LOCAL CITY, COUNTY OR STATE REQUIREMEN-S. 1C. THE CONTRACTOR WILL BE REQUIRED TO PLACE TEMPORARY AND/OR PERMANENT PAVING IN ACCORDANCE WITH ANY LOCAL CITY, COUNTY OR STATE REQUIREMENTS. 11. USE #10 WIRE ON ALL MAINS AND SERVICES. 12. REFER TO GAS STANDARD J-15 FOR GAS METER LOCATIONS. McKEE RD. O 00 00 rnCn N PROJECT - L- Ln Lil Q SITE z� Cn Ln Q o /o I..L r -L LTJ o Z O N = m 00 SII < Li l Z N V, TAFT HWY NTS VICINITY MAP APPLICANT TO VERIFY RIGHT OF WAY, THE CONTRACTOR SHALL OBTAIN ALL APPLICABLE PUBLIC UTILITY EASEMENT AND/OR PUBLIC SERVICE PERMITS PRIOR TO COMMENCING THE WORK EASEMENT ACQUISITION PRIOR TO CONSTRUCTION AT NO COST TO PG&E. LEGEND: PROPOSED SERVICE PROPOSED MAIN LINE EXISTING GAS FACILITY PROPOSED 5 -LB ZINC ANODE PROPOSED 4' x 6' x 12" BELLHOLE (12" UNDER PIPE) �F-EFV PROPOSED EXCESS FLOW VALVE EQ PROPOSED ETS BOX LOCATED IN OR BEHIND SIDEWALK DESIGN CHANGE COMPONENT ANY CHANGES TO THIS DESIGN MUST BE APPROVED BY DOMINIC OTHART (661) 398-5817 PG&E GAS ADE RECAP 1. INSTALL 1,671' OF 2" HP PL MAIN 2. INSTALL (2) ETS STATIONS 3. INSTALL (3) 5# ZINC ANODES 4. INSTALL (37) 1# MAGNESIUM ANODES 5. INSTALL (21) 1" EFV VALVES (5) 800 SERIES (16) 1100 SERIES 6. INSTALL (21) 1" PL SERVICE STUBS (572') 7. INSTALL (38) 1" PL SERVICE COMPLETIONS (950') 8. TIE-INS (2) 2" PL X 2" PL (BY PGE) No. M31650 o�. e,/agp�on OF1®111�1►.�pQ� PLAT 5126-D6 M.A.O.P. 60 PSIG C.P.A./C.P.S 512600 T.B.A. T-01 EMERGENCY ZONE: 6 5 4 3 LIJ O M O U U � Z U Z UJ o Of LU LL Ld ftf 2 N cn CV C3 Q C7 ck� O 00 00 rnCn N L - L- Ln Lil Q L) Q Cn Ln CV Z r -L LTJ o Z O N rn rn m M SII O Li l Z N 0o O LiJ� U O Q Q O Q = :M CC c- U U a L,J D Q Ln TF11 L� L t I U r M H- I w U = O O I = m O U U Z O t/') aZ CO o_ Q 00 � o Z O a rn 0 z 0..f cn N N E.y Y - 0 Y rn u7 Q m O .--I 2 U w z 3 cry O' U o U 0 00 I O ,by M N a .M Z E- W 0 -4 O 0 w Z o_ D_ O ■ ■■ rte-+ all cn CV C3 Q C7 ck� O 00 00 rnCn N Cl U c 2L - L- Ln Lil Q L) Q Cn o m Z LTJ o Z O rn rn m 0 SII U Li l Z J Z O LiJ� U O Q Q d Q = :M CC c- U U a L,J D Q Ln TF11 t I r M w U c0 0 O J Z�- CO o_ Q 00 E-• LLL a 0 z 0..f N Ems-, Y - 0 Y Q m O 2 U w z 3 cry Q 0 W 0 0 0 .z IN n 1 INCH 0 1 U Z 0 V) W Z LTJ Q Q Z Z O O ►�-i L.L W J w U c0 O O J Z�- CO 00 E-• LLL 0 z 0..f Ems-, Y Q m O w cry Q 1 INCH 0 1 U Z 0 r � ,• ,�� � �.: LEGEND INSTALL DESCRIPTION D4 D4 VACANT DUCT 4" D6 D6 VACANT DUCT 6" -P PP PRIMARY CABLE - 1-1/OAL EPR ENCAP IN EXISTING 1-2" CONDUIT P1 P1 PRIMARY CABLE - 1-1/OAL EPR ENCAP IN NEW 1-2" CONDUIT S S S SECONDARY CABLE - 1/OAL TPX IN NEW 1-3" CONDUIT S1 S1 SECONDARY CABLE - 4/OAL TPX IN NEW 1-3" CONDUIT S2 S2 SECONDARY CABLE - 350AL TPX IN NEW 1-4" CONDUIT SV SV SERVICE CABLE - 4/DAL TPX IN NEW 1-3" CONDUIT SVl _SV1 SERVICE CABLE - 1/OAL TPX IN NEW 1-3" CONDUIT STREETLIGHT CABLE EXISTING DESCRIPTION -2X 3 PHASE PRIMARY CABLE/CONDUCTOR - SIZE AS SHOWN 13 CUST 1 PHASE PRIMARY CABLE/CONDUCTOR - SIZE AS SHOWN - - - - - VACANT CONDUIT (PRIMARY) - SIZE AS SHOWN INSTALL EXISTING DESCRIPTION 1-f 11 F22 17" x 30" x 18" SECONDARY BOX LJ 17" x 30" x 26" SECONDARY BOX X317 24" x 36" x 18" SECONDARY BOX 3E 24" x 36" x 26" SECONDARY BOX F5 3' x 5' x 3'6" PRIMARY ENCLOSURE L6J 4' x 6'6" x 5' PRIMARY ENCLOSURE W® PM TRANSFORMER, DF -LB, SIZE AS SHOWN FRONT 100KVA r: LS2A STREET LIGHT Q END OF CONDUIT - BALL MARKER 120/240V E) SOLELY OWNED POLE W/ FOREIGN CONTACT SOLELY OWNED ANCHOR TO T -3X TRF# TX. SIZE #CUST BUISH. RE KVA. P1 VOLS COORDINATE # SERIAL NUMBER P1 TO T -2X 12 CUST ENCLOSURE DETAIL IS INTENDED FOR CONDUIT ENTRANCE INFORMATION ONLY. PLEASE REFER TO JOINT TRENCH DRAWING FOR EXACT LOCATION IN REFERENCE TO CURB, SIDEWALK, PUE, AND P/L. ENVIRONMENTAL ISSUES ❑ NONE APPARENT (IF PROJECT DESIGN CHANGES, CONTACT ADE) ❑ BASED ON APPLICANT/DEVELOPER-SUPPLIED PLANS ❑ PERMITS ❑ TAILBOARD ❑ OTHER ❑ APPLICANT DESIGN/RESPONSIBILITY (CHECK PERMITS BOX IF PERMIT CONDITIONS APPLY TO PG&E ACTIONS.) SIGNATURE Underground Service Alert Call: Toll Free 811 CALL TWO WORE ING DAYS BEFORE YOU DIG PG&E GAS CONFLICT IDENTIFIED FOR THIS PROJECT GAS PLAT: 5126-C6 PG&E GAS FACILITIES IN PROXIMITY WITH EXCAVATION AT LOCATION(S) - 1 J -1X CODE 04-1495 4' X 6'-6"X 5'D IVT. BOX 12 NOTES 1. THIS IS AN APPLICANT DESIGN AND INSTALL PROJECT. 2. TRENCH TO BE JOINT WITH ELECTRIC, GAS, PHONE & CAN. 3. APPLICANT SHALL OBTAIN ALL NECESSARY PERMITS.. 4. RIGID CAP ALL SPARE CONDUITS. 5. IMPORTANT! DEVELOPER, GENERAL & ELECTRICAL CONTRACTOR BEFORE BEGINNING SUBSTRUCTURE WORK, PLEASE CONTACT PGE UNDERGROUND TRENCH INSPECTOR AT LEAST TWO BUSINESS DAYS PRIOR TO REQUESTING INSPECTION. REQUEST FOR INSPECTIONS RECEIVED AFTER 12:OOPM WILL NOT BE INSPECTED UNTIL THE 3RD WORKING DAY. (WORK NOT PROPERLY INSPECTED, MAY BE REJECTED) 6. APPLICANT CONTRACTOR TO LOCATE ALL UNDERGROUND FACILITIES BEFORE TRENCH & EXCAVATION. CALL UNDERGROUND SERVICE ALERT AT 811 AT LEAST TWO WORKING DAYS PRIOR TO DIGGING. 7. DO NOT EXCEED 300 DEGREES OF BENDS IN ANY CONDUIT RUN (INCLUDING BEND AT THE FEED LOCATION). 8. PROVIDE CLEARANCES AND WORKING SPACE PER PGE DWG. 051122. 9. PGE SHALL INSPECT ALL WORK AND PERFORM ALL HOT TIE-IN WORK. 10. BOX AND CONDUIT SIZES AND LOCATIONS SHALL CONFORM TO THE PGE ELECTRIC CONSTRUCTION DWG. 062288. 11. ENCLOSURES SHALL CONFORM TO THE PGE ELECTRIC CONSTRUCTION DWG. 062000. 12. APPLICANTS CONTRACTOR TO PERFORM ALL AND ANY NECESSARY INCIDENTAL TRENCHING, BACKFILL, COMPACTION AND PAVING. 13. SEE UTILITY COMPOSITE DRAWING FOR ACTUAL TRENCH & SUBSTRUCTURE LOCATIONS 14. 800 SERIES SKETCH LOCATIONS INDICATE PG&E WORK. I TO T-1 X 801 LOC 800 TO LOC 802 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 193LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS.......... CABLE PULLING DATA 8O LOC 12 TO LOC 4 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 232LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS.......... ALL RES SERVICES ARE INVENTORIED AT LOC SEE JOB INSTRUCTIONS OR CONDUIT IN 42 FRANCHISE AND PRIVATE PROPERTY. PG&E TO INSTALL HOUSE SERVICE CABLE. TRANSFORMER DATA TABLE LOC.# TRF# TX. SIZE #CUST BUISH. RE KVA. VOLTS VOLS COORDINATE # SERIAL NUMBER MANUFACTURER OT-1 X 100KVA 12 CUST 1W/2B 88 21 KV 120/240V 0 GDVT -2X 100KVA 13 CUST 1W/2B 96 21 KV 120/240V + 1 METER CK) T -3X 100KVA 12 CUST 1 W/2B 88 21 KV 120/240V T-28447 100KVA 12 EX CUST 1W/2B 85 21 KV 120/240V 1 NEW TYPICAL 36" X 52" PAD DETAIL 16 LOC 20 TO LOC 12 USE 2.5 -GAL & 2- FRONT END PKS EST. PULL 133LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS.......... PG&E PAD CODE 36-001 36" 39 LOC 37 TO LOC 12 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 160LBS. ACTUAL PULL ............ LBS. FOREMAN'S INITIALS.......... Group All Secondary Conduits Together Near the Back of the Window Secondary Primnry CnnrilNlt Section C d -.t S t' On U.ec Ion of Pad ns ns Detail A Placement of Conduits GENERAL DESIGN INFORMATION: STREET LIGHTS — LS2A LARGEST HOME = 2500 AVG HOUSE SIZE BASED 200 AMP MAN PANELS ON 2111 SQ FT HOME SCI 10,000 AT ALL PANELS 5 TON A/C UNITS (170 LRA) THIS JOB WILL BE FULL APPLICANT CONSTRUCTION. APPLICANT TO TRENCH, BACKFILL, INSTALL ALL SUBSTRUCTURE AND DISTRIBUTION. PG&E TO PERFORM TIE IN WORK AND SERVICE FACILITIES. THIS SKETCH IS INTENDED FOR ELECTRIC CONSTRUCTION ONLY. PLEASE SEE JOINT TRENCH COMPOSITE FOR TRENCHING DETAILS. THESE DRAWINGS ARE CONSIDERED PRE-IMINARY AND AT RISK, UNLESS STAMPED AND APPROVED BY PG&E AND P.E. CIR MAP 30275-C PLAT 3027346 INS DIST: B CLIMATE ZONE R STOCKDALE 2112 VOLT CLASS 1 LOADING DIST: SI LIGHTNING DIST: 2 NON -CORROSIVE Lopes Utility Design Services WWW.LopesUDS.com NO. REWSM wElectric Design by: L*P..0 DESIGN SERVICES Office (5 59) 641 2954 46325 Wallu Lane Cell (559) 760 9464 Ahwahnee, California 93601 ELECTRIC CONSTRUCTION SKETCH TRACT 6 75 8 PHASE 4 S/W OF WAREHAM DR & HATHAWAY AVE FOR: LENNAR HOMES BAKERSFIELD CALIFORNIA 800-22 a 260 y° �,��,�' ND SER Project Management by: California Utility lity Consultants Inc 7591 N Ingram Ave. Suite 103 Fresno, CA 93711 Phone (559) 261-9880 Fax (559) 261-9707 RULE 15,16 PM 31223169 NOT 111377591 DATE 4/26/2016 SHEET SCALE AS SHOWN DESIGNER Cuff Lopes El DRAFTER Cuff Lopes 1O8 I OF E3 SHEETS pES AlUTILITY 0 0 € _ '` �24 25 2 (3 2 VD 2.9 -- FD 2.9 FD4.1,�8 29 30 15 j et t4.1 VD CALC FIGURED ON 1 31174863 ' 4CT 6758 PH 3 i 5.8 6.7 3 8 5' EXIST O 20'/39' 160'/174' 803 38 �1 s1 — P1 PULL - 37 T -3X 100 KVA 530'/567' 60'/74 37 F 36 04 I N sk 35 VD 2.9120'/134' N 36FD 2.8 Z 0 :)E: 36 i IJ5 34 A V E N U E 33 32 3-1 32 106] J rn Q � I �I t— 0 0 I I� 1 - 1, OAL 1-1 /OAL WI -� T�77225 100 KVA 5 6 7 8 9 VD 6.3 VD 6.1 FD 6.2 FD 5.7 aAL 125'/ 139' 125 1 S1 S1 S1 S1 -N� 13J 1X I, GE) / 40...,__._.. 6 V—si S1 — P1 P1 P1 P1 P1 P1 ..7___ P1 P1 _ ._._.- P1 P1 ?i_ P1 _. P1 P1 340 /377 P1 P1 P1� P1 H A T C H V I L L E PULL A V E N U E a 16 I �I 634P9 1 ��` Cn 150'/164 � Ij 29 2 8 i 60'/25'/99'18 (n ! I � 2E SP 60'/25'/99' 60'/74 v`�i (L 27 I3 19 � II � (I 30 N U) (n� 20 60'/25'/99 ~ 60'/25'/99' 21 a 1 160'/25'/200'/ 19 1-1/OAL 801 CD 310' EXIST 155'/496' TIE INTO 2" VD 3.3 12 FD 3.6 60'/25'/99' 13 CD 7 2� 175'/19:' Ski` j S27-7 S2 S2 P1 _ -- l� �E ? 14 N O —� 360'/397' PULL`cq 60'/74' CD T -1X 100 KVA 4 802 N O 15 160'/74 Q W SV CDVD 2.8 FD 2.7 16 65'/25'/105'----'3'4 VD 4.0 145'/160'` FD 3.7 24 �3 `�� 24 LANDSCAPE METER O C 10'/24', -SV1-t 634Q9 s' --- SCI 10,000, 1 KVA L S�� :---- 634Q4 634Q8 1 - EM 4 D4 D4—D4----D4—D4--D4 EM—D4—D4—D4—p4—D4 04 D4—D4-D4—D4—p4 D4--D4—p4 D4—p4 - - - -- 6 D6—D6—D6—D6_D6—D6—D6—D6—D6 D6 D6 D6 D6—D6—D6—D6—D6—D6 D6—D6—D6—pg_D6_D6—D6—D6 6 D6 D6—D6 `D4--D4—D4—D4—D4—D4—D--4 - 6 D4—D4 D4 mm D4 9 D4 D4 M 6—D6 D6—D6—D6-----D6—D6--D6—D6—D6—D6—D6—D6 —D6 T A F T H I G H W A Y 1,C50' 1,050' CONDUIT INSTALLED THE EXTENT OF 027 UNIT 4 IMPROVEMENTS ON TAFT HWY 26 FOR FUTURE MAINLINE LOOP 100' STUB TO S/S OF TAFT HIGHWAY 3-2AL 12KV 3-2AL 12KV iGE) FOR FUTURE 30 PUMP TIE IN 3-2AL 12KV 3-2AL 12KV 3-2AL 12KV 45' 45' 40' 45' J-25229 800 41 II CIR MAP 102'75---C PLAT 302;'346 INS DIST: 3 CLIMATE ZONE R STOCKDALE 2112 VOLT CLASS 1 LOADING DIST: S LIGHTNING DIST: 2 NON—COR=ROSIVE 1 , Lopes Wiity Design Services WWW.LopesUDS.com SCALE: 1 "=40' SCALE 40' 0 40' 8 NO• '1S1ON BY Electric Design by:ELECTRIC ETRACT UTILITY DESIGN SERVICES O ce (559) 641 2954 46325 Wallu Lane Cell (559) 760 9464 Ahwahnee, California 93601 CONSTRUCTION SKETCH 6758 PHASE 4 S W OF WAREHAM DR & HATHAWAY AVE � FOR: LENNAR HOMES BAKERSFIELD CALIFORNIA 800-22 a 260 0� Yo � �� ��,�' ��"°SVEE R� Project Management by: CaliforniaC lifoiUtility Consultants Inc �' 7591 N Ingram Ave. Suite 103 Fresno, CA 93711 Phone 559 261-9880 Fax 559 261-9707 DATE 4/26/2016 RULE 15,16 � SCALE ASsHo� PM 312 2 3169 DESIGNER tiff Lopes NOT 111377591 9 DRAFTER cuff Lopes _- i -JOB SHEET E2 I OF E3 SHEETS �SULE Al� k TO J-8625 F J-15375 01 > Y N 0 T-75034 50 KVA AO 5 CUST I I I I 1-1/OAL 3-1 /OAL FI J-98534 3-1 /OAL SSF-56606 3 WIRE SS FUSE 48 CUST IN=IE=7.8AMPS ® 21 KV INSTALL 20CL AO=8 AMPS, 17 CUST BO=8.5 AMPS, 18 CUST CO=6 AMPS, 13 CUST �[5 T23813 50KVA tn J-4668 > Y N J Q O O to J-5530 T 6"1 I I I I I CIRCUIT SKETCH LEGEND INSTALL DESCRIPTION D4 -D4 VACANT DUCT 4" D6 D6 VACANT DUCT 6" P P P PRIMARY CABLE - 1-1/OAL EPR ENCAP IN EXISTING 1-2" CONDUIT P1 P1 PRIMARY CABLE - 1-1/OAL EPR ENCAP IN NEW 1-2" CONDUIT EXISTING DESCRIPTION � ,� SHo� 1 PHASE PRIMARY UG CONDUCTOR - SIZE AS SHOWN 3 PHASE PRIMARY UG CONDUCTOR - SIZE AS SHOWN — — — — — — — VACANT CONDUIT (PRIMARY) - SIZE AS SHOWN INSTALL EXISTING DESCRIPTION m 200A SEPARABLE DEADBREAK CONNECTOR 200A SEPARABLE LOADBREAK CONNECTOR Q PADMOUNT TRANSFORMER - SIZE AS SHOWN ePMH -4 PADMOUNT FUSE SUBSURFACE SWITCH 3 WAY 2 WAYS SWITCHED OSUBSURFACE SWITCH 2 WAY SWITCH SUBSURFACE FUSED SWITCH OSUBSURFACE TRANSFORMER SIZE AS SHOWN - SUBSURFACE SWITCH 3 WAY 3 WAYS SWITCHED FAULT INDICATOR J-15375 01 > Y N 0 T-75034 50 KVA AO 5 CUST I I I I 1-1/OAL 3-1 /OAL FI J-98534 3-1 /OAL SSF-56606 3 WIRE SS FUSE 48 CUST IN=IE=7.8AMPS ® 21 KV INSTALL 20CL AO=8 AMPS, 17 CUST BO=8.5 AMPS, 18 CUST CO=6 AMPS, 13 CUST �[5 T23813 50KVA tn J-4668 > Y N J Q O O to J-5530 T 6"1 I I I I I T-64305 100 KVA 12 CUST EXISTING UNIT 3 J-86997 4" T-53639 50 KVA BO EM 9 CUST STUB UP TO 52 FUTURE CUSTOMERS. I FUTURE 3-1100AL FUTURE MAINLINE LOOP I T-27417 100 KVA 8 EX CUST, 2 NEW ESD 77 KVA AO CAPE 1-1/OAL REFER TO PM 31042992 FOR INSTALLATION OF PHASE 2 T-64352 100 KVA 9 EX CUST, 2 NEW ESD 81 KVA Co 1-1 /OAL w Z g 0 Y 1110� 2-1 /OAL T-44960 50 KVA BO 9 CUST T-91010 100 KVA 15 CUST ESD 107 KVA AO COD - 1-1/OAL EXISTING UNIT 2 T-79261 100 KVA 11 CUST ESD 81 KVA AO DRIVE EXISTING UNIT 2 T-56999 100 KVA 12 CUST ESD 88 KVA Co PROVINCETOWN AVE. 1-1 /OAL HATHAWAY T-28447 100 KVA Co 12 EX CUST+1 NEW F-19410 3-65E IN= A PHASE 83 CUST = 43AMPS J-45629 B PHASE 73 CUST = 38AMPS _I �— 7,7 C PHASE 75 CUST = 39AMPS 1-1 /OAL IFI) T-13935 T-13934 Q FI T-55909 100 KVA 100 KVA \I 100 KVA 10 CUST 12 CUST T 13 CUST B0 BO ESD 95 KVA AO— FI T-63339 1-1/OAL T-42464 100 KVA J 100 KVA 12 CUST I o 12 CUST - ESD 88 KVA T-13936 0 ESD 88 KVA AO I 100 KVA BO 14 CUST 1-1 /OAL FI AO 1-1/OAL J-2339 AJ-13603 ASHINTULLY AVE. F, FI Q 1-1/OAL I 0 �— 2-1/OAL EMSTH\IC; I T-13897 100 KVA I I UNIT 1 J-25229 15 CUST � , I FI BO 1-1 /OAL 1 DRIVE I T-92471 FI — 50 KVA 8 CUST I a j I ESD 64KVAcr_ AO I p LL A --h (F) j �_17 2 -1 /OAL � 1-1 /OAL FI J-35333 T-77225 100 KVA 10 EX CUST, 5 NEW ESD 107 KVA Co ■ LTJ REFER TO PM 31036850 FOR INSTALLATION OF PHASE 1 0 O z z D 12 Z 19415 J-2328 3-1/OAL y. TIE INTO 2" I 1 -1 /OAL PROSPOSED UNIT 4 a � FI 1 T-13899 T-13898 I 100 KVA 100 KVA 12 CUST 12 CUST BO BO a I I I � I I I W P1 P1 P1 P1,4 P1 P1 P1 wHATCHVILLE DRIVE T -1X Z T -3X 100 KVA O 100 KVA EH- 12 CUST ~ 12 CUST(n Co Co I T -2X I 100 KVA Ld 13 CUST Co CSD I I I EM I 0 I I I I �D6 D6 D6 D6 —D6 D6 D6 D6 D6 D6 I D4—D4—D4 —D4 D4 D4 D4 D4 D4 D4 EM I -------------------------------------------------------------------------------------------------------------------- ---------------------------------------------------------j TAFT HIGHWAY STUB TD S/S OF TAFT HIGHWAY FOR FUTURE 30 PUMP TIE IN 3-2A 12KV EM CONDUIT INSTALLED THE EXTENT OF UNIT 4 IMPROVEMENTS ON TAFT HWY FOR FUTURE MAINLINE LOOP CIR MAP 30275-C PLAT 3027346 INS DIST: B CLIMATE ZONE R STOCKDALE 2112 VOLT CLASS 1 LOADING DIST: SI LIGHTNING DIST: 2 NON -CORROSIVE T 9416 Ld 0 0 Z Z D F-194 19417 0 Li z O Cn w V) z SCALE: N.T.S. NO' W w Z ELECTRIC CIRCUIT SKETCH TRACT 6 7 5 8 PHASE 4 S/W OF WAREHAM DR &HATHAWAY AVE • FOR. LENNAR HOMES BAKERSFIELD CALIFORNIA 800 L22R -2so � � � � �^ � � �. �”"� SERA 01�g RULE 15 ,16 PM 312 2 3169 NUT 1 1 1 3 7 7 5 91 0 SHEET E 3 OF E3 SHEETS � � ,� SHo� J O LL_ J m W Ld Q T-64305 100 KVA 12 CUST EXISTING UNIT 3 J-86997 4" T-53639 50 KVA BO EM 9 CUST STUB UP TO 52 FUTURE CUSTOMERS. I FUTURE 3-1100AL FUTURE MAINLINE LOOP I T-27417 100 KVA 8 EX CUST, 2 NEW ESD 77 KVA AO CAPE 1-1/OAL REFER TO PM 31042992 FOR INSTALLATION OF PHASE 2 T-64352 100 KVA 9 EX CUST, 2 NEW ESD 81 KVA Co 1-1 /OAL w Z g 0 Y 1110� 2-1 /OAL T-44960 50 KVA BO 9 CUST T-91010 100 KVA 15 CUST ESD 107 KVA AO COD - 1-1/OAL EXISTING UNIT 2 T-79261 100 KVA 11 CUST ESD 81 KVA AO DRIVE EXISTING UNIT 2 T-56999 100 KVA 12 CUST ESD 88 KVA Co PROVINCETOWN AVE. 1-1 /OAL HATHAWAY T-28447 100 KVA Co 12 EX CUST+1 NEW F-19410 3-65E IN= A PHASE 83 CUST = 43AMPS J-45629 B PHASE 73 CUST = 38AMPS _I �— 7,7 C PHASE 75 CUST = 39AMPS 1-1 /OAL IFI) T-13935 T-13934 Q FI T-55909 100 KVA 100 KVA \I 100 KVA 10 CUST 12 CUST T 13 CUST B0 BO ESD 95 KVA AO— FI T-63339 1-1/OAL T-42464 100 KVA J 100 KVA 12 CUST I o 12 CUST - ESD 88 KVA T-13936 0 ESD 88 KVA AO I 100 KVA BO 14 CUST 1-1 /OAL FI AO 1-1/OAL J-2339 AJ-13603 ASHINTULLY AVE. F, FI Q 1-1/OAL I 0 �— 2-1/OAL EMSTH\IC; I T-13897 100 KVA I I UNIT 1 J-25229 15 CUST � , I FI BO 1-1 /OAL 1 DRIVE I T-92471 FI — 50 KVA 8 CUST I a j I ESD 64KVAcr_ AO I p LL A --h (F) j �_17 2 -1 /OAL � 1-1 /OAL FI J-35333 T-77225 100 KVA 10 EX CUST, 5 NEW ESD 107 KVA Co ■ LTJ REFER TO PM 31036850 FOR INSTALLATION OF PHASE 1 0 O z z D 12 Z 19415 J-2328 3-1/OAL y. TIE INTO 2" I 1 -1 /OAL PROSPOSED UNIT 4 a � FI 1 T-13899 T-13898 I 100 KVA 100 KVA 12 CUST 12 CUST BO BO a I I I � I I I W P1 P1 P1 P1,4 P1 P1 P1 wHATCHVILLE DRIVE T -1X Z T -3X 100 KVA O 100 KVA EH- 12 CUST ~ 12 CUST(n Co Co I T -2X I 100 KVA Ld 13 CUST Co CSD I I I EM I 0 I I I I �D6 D6 D6 D6 —D6 D6 D6 D6 D6 D6 I D4—D4—D4 —D4 D4 D4 D4 D4 D4 D4 EM I -------------------------------------------------------------------------------------------------------------------- ---------------------------------------------------------j TAFT HIGHWAY STUB TD S/S OF TAFT HIGHWAY FOR FUTURE 30 PUMP TIE IN 3-2A 12KV EM CONDUIT INSTALLED THE EXTENT OF UNIT 4 IMPROVEMENTS ON TAFT HWY FOR FUTURE MAINLINE LOOP CIR MAP 30275-C PLAT 3027346 INS DIST: B CLIMATE ZONE R STOCKDALE 2112 VOLT CLASS 1 LOADING DIST: SI LIGHTNING DIST: 2 NON -CORROSIVE T 9416 Ld 0 0 Z Z D F-194 19417 0 Li z O Cn w V) z SCALE: N.T.S. NO' SON w Electric Design by: �� � � UTILITY DESIGN SERVICES Office (559) 641 2954 46325 Wallu Lane Cell (559) 760 9464 Ahwahnee, California 93601 ELECTRIC CIRCUIT SKETCH TRACT 6 7 5 8 PHASE 4 S/W OF WAREHAM DR &HATHAWAY AVE • FOR. LENNAR HOMES BAKERSFIELD CALIFORNIA 800 L22R -2so � � � � �^ � � �. �”"� SERA p�j� Management by: California Utili Consultants Inc �' 7591 N Ingram Ave. Suite 103 Fresno, CA 93711 Phone (559) 261-9880 Fax 559 261-9707 ( ) RULE 15 ,16 PM 312 2 3169 NUT 1 1 1 3 7 7 5 91 DATE 4/26/2016 SHEET E 3 OF E3 SHEETS � � ,� SHo� � DESIGNER Cliff � 0 D,� �„�,.� Q 1O8