HomeMy WebLinkAbout1.8-7246 Ph 2I , 13 /C;)"( 4 ' Z,�- 1 � — �'� � �1 C� � s� �,. APPLICANT TO TRENCH, BACKFILL, INSTALL ALL SUBSTRUCTURE, AND INSTALL ALL DIST FACILITIES. PG&E TO PERFORM TIE IN WORK AND INSTALL SERVICE FACILITIES. THIS SKETCH IS INTENDED FOR ELECTRIC CONSTRUCTION ONLY PLEASE SEE JOINT TRENCH COMPOSITE FOR TRENCHING DETAILS AND SUBSTRUCTURE INSTALLATION DETAILS THESE DRAWINGS ARE CONSIDERED PRELIMINARY AND AT RISK, UNLESS STAMPED AND APPROVED BY PG&E AND P.E. NOTES 1. THIS IS AN APPLICANT DESIGN AND INSTALL PROJECT. 2. TRENCH TO BE JOINT WITH ELECTRIC, GAS, PHONE do CATV. 3. APPLICANT SHALL OBTAIN ALL NECESSARY PERMITS.. 4. RIGID CAP ALL SPARE CONDUITS. 5. IMPORTANT! DEVELOPER, GENERAL & ELECTRICAL CONTRACTOR BEFORE BEGINNING SUBSTRUCTURE WORK, PLEASE CONTACT PGE UNDERGROUND TRENCH INSPECTOR AT LEAST TWO BUSINESS DAYS PRIOR TO REQUESTING INSPECTION. REQUEST FOR INSPECTIONS RECEIVED AFTER 12'OOPM WILL NOT BE INSPECTED UNTIL THE 3RD WORKING DAY. FAX Q 661-398-5985 CALL ® 661-398-5711 OEM NOT PROPERLY INSPECTED, MAX BE REJECTED) 6. APPLICANT CONTRACTOR TO LOCATE ALL UNDERGROUND FACILITIES BEFORE TRENCH & EXCAVATION. CALL UNDERGROUND SERVICE ALERT AT 811 AT LEAST TWO WORKING DAYS PRIOR TO DIGGING. 7. SECONDARY AND SERVICE CONDUITS SHALL ENTER BOXES FROM UNDERNEATH WITH 90 DEGREE VERTICAL BENDS. EXCEPT FOR BOXES ADJACENT TO TRANSFORMERS. 8. DO NOT EXCEED 300 DEGREES OF BENDS IN ANY CONDUIT RUN (INCLUDING BEND AT THE FEED LOCATION). 9. PROVIDE CLEARANCES AND WORKING SPACE PER PGE DWG. 051122. 10. PGE SHALL INSPECT ALL WORK AND PERFORM ALL HOT TIE-IN WORK. 11. CONDUIT SIZES AND LOCATIONS SHALL CONFORM TO THE PGE ELECTRIC CONSTRUCTION DWG. 062288. 12. ENCLOSURES SHALL CONFORM TO THE PGE ELECTRIC CONSTRUCTION DWG. 062000. 13. APPLICANTS CONTRACTOR TO PERFORM ALL AND ANY NECESSARY INCIDENTAL. TRENCHING, BACKFILL, COMPACTION AND PAVING. 14. SEE UTILITY COMPOSITE DRAWING FOR ACTUAL TRENCH & SUBSTRUCTURE LOCATIONS 15. APPLICANT TO PROVIDED PUES AND RIGHTS OF WAY AS REQUIRED. 16. 800 SERIES SKETCH LOCATIONS INDICATE PG&E WORK. GENERAL DESIGN INFORMATION: PRIVATE STREET LIGHTS LARGEST HOME = 4000 AVG HOUSE SIZE BASED ON 3860 SQ FT HOME 200 AMP MAIN PANELS SCI 10,000 AT ALL PANELS 5 TON A/C UNITS (170 LRA) TRANSFORMER DATA TABLE LOC.j TRF# TX. SIZE ICUST WIRE BUSH. ESD. KVA. PRI. VOLTS SEC. VOLTS COORDINATE SEFIAL NUMBER MANUFACTURER 1ls3'eF T-91928 1OOKVA 12 CUST 1W/2B 101 21 KV 120/240V V x V x 3'6' PR's►MRY ENCLOSURE ® 1$ T-27808 1OOKVA 12 GUST 1W/28 101 21 KV 120/240V tE T-44392 100KVA 8 CUST 1W/2B 71 21 KV 120/240V I I T-59373 I 1OOKVA 1 8 OUST 1W/28 71 21 KV 120/240VT T I ALL RES SERVICES ARE INVENTORIED AT LOC SEE JOB INSTRUCTIONS FOR CONDUIT IN FRANCHISE AND PRIVATE PROPERTY. GD PG&E TO INSTALL SERVICE CABLE. 21 SOQ J-72752 4'x6'6'x5'DNT.BOX ENVIRONMENTAL ISSUES NONE APPARENT (IF PROJECT DESIGN OW4GES, CONTACT ADE) L) BASED ON APPLICANT/DEVELOPER-SUPPLIED PLANS ❑ PERMITS ❑ TAILBOARD ❑ OTHER ❑ APPLICANT DESIGN/RESPONSIBILITY (CHECK PERMITS BOX IF PERMIT CONDITIONS APPLY TO PG&E ACTIONS.) SIGNATURE ENCLOSURE DETAILS ARE INTENDED FOR CONDUIT ENTRANCE INFORMATION ONLY. PLEASE REFER TO JOINT TRENCH DRAWING FOR EXACT LOCATION IN REFERENCE TO CURB, SIDEWALK, PUE, AND P/L. FROM T-27808 go Pi C SPLICE BOX 3' x 5' x 316'D Pa. sox 1t TO T-91928 CABLE PULLING DATA 1Q LOC 5 TO LOC 11 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL i 04LBS. ACTUAL PULL ........... LOS. FOREMAN'S INITIALS .......... 12 LOC 15 TO LOC 11 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 77LBS. ACTUAL PULL ........ ...LBS. FOREMAN'S INITIALS.___ 18 LOC 15 TO LOC 21 USE 2.5 -GAL & 2- FRONT DID PKS. EST. PULL 112LBS. ACTUAL PULL ........... LBS. FOREMAN'S INITIALS-...._ AJ LOC Ni TO LOC 21 USE 2.5 -GAL dt 2- FRONT END PICS. EST. PULL 110LEI1. ACTUAL PUU_...........LBS. FOREMAN'S INITIALS......... (D LOC .ki TO LOC 25 USE 2.5 -GAL do 2-- FRONT END PKS. EST. PULL 151UG. ACTUAL PULL ...... ......19S. FOREMAN'S INITIALS.......... LOC 13 )3 TO LOC 800 USE 2.5 -GAL & 2- FRONT END PKS. EST. PULL 9" ACTUAL PULL...........LOS. FOREMAN'S INITIALS.......... LEGEND INSTALL DESCRIPTION ---P1---P1 PRUW CABLE - 1-1/0M_ EPR ENCAP IN NEW 1-2' COMM -:-----P4 PR*IARY CABLE - 1-1/ac EPR EmCAP IN EX1Srm 1-2' comir -----_�� ---61 SE(CIARY CABLE - 4/0u. 7PX IN NEW 1-3' OONDLIFT ----SZ SE XINDARY 00aK - 3%9. TPX IN NEIN 1-r MKIIA T -----•--s--SS Y CABLE - 350N. TPX N E09TM 1-4' CONOW -------$11------ WSERVICE CABLE - 4/DAL 'n"A IN NEW 1-r CMW PFM7E SIREETLI#iT a a TEVIS 2102 CIR MAP 30264 PLAT 3026131 INS DIST:B CLIMATE ZONE R VOLT CLASS 1 LOADING DIST: SI LIGHTNING DIST: 2 NON --CORROSIVE PG&E Plan Chock doeffi wt release to from Iespomhft to com ul the ficuities womm 3g to PG" StsndaedL In the a want of a Congos daringoomftdioo betty m t PG&E and the plam, PG l:E Stm&rds will amtmL Final � t Dam ; i .S ft lim sw-Ac. SCALE: 1 "=40' SCALE" 40' 0' 40' fi0' mm 3 MASE PR MARY CABIf./WM)JCTt7R - SIZE AS SOWN ...._.-.......�......-..- 1 PHASE PRIUARY CASWC010)CM - SQE AS SHOMM .,,- .� .� .... _... VACANT CM10W (PRIMW k't) - !;IZE AS SMOMM INSTALL EXISTING DESCRIPTION . D ® iT x 30' x Ir I;r=NDW Box 1ls3'eF ® 17' x 30' x 26' %-WNDARY 9W �etllic cw tq m ff 24' x ae x 2a' 14VONDARr SWC ® V x V x 3'6' PR's►MRY ENCLOSURE ® 4' x 6V x 5' PRIkARY VOLOSURE ® 4'6' x 8'6' x a' I' MAW ENCLOSURE ® ® PM TROWDRMER. OF LB. SIZE AS SHMN PFM7E SIREETLI#iT a a TEVIS 2102 CIR MAP 30264 PLAT 3026131 INS DIST:B CLIMATE ZONE R VOLT CLASS 1 LOADING DIST: SI LIGHTNING DIST: 2 NON --CORROSIVE PG&E Plan Chock doeffi wt release to from Iespomhft to com ul the ficuities womm 3g to PG" StsndaedL In the a want of a Congos daringoomftdioo betty m t PG&E and the plam, PG l:E Stm&rds will amtmL Final � t Dam ; i .S ft lim sw-Ac. SCALE: 1 "=40' SCALE" 40' 0' 40' fi0' mm OLIN Oil �: L*P E 5 UTMW DESIGN smnczs umm (SS9) 6412954 46325 WaN Lam Cd (559) T64 9464 Catl bnda 93601 EUEcr�e coNSTRu�noN SKETCH TRACT 7246 PHASE 2 1WOODME)GE WHITE LANE AND BUENA VISTA a Ilq FEwn IIS -, D mm l rs GVAWAWLTROMLnraW A 0W0°-=7- � , *," �: - California Utility Consultants Inc 7591 N Ium m Ave. Sake ilk Fre=6 CA 93711 Pix-oune (559) 261-9680 Fax (559) 261-9M _ RULE I So 16 PM 31115 789 ni�T 109612824 a"'l El of rA. std WAR ,S, A �etllic cw tq m ff ��R Crlrt�aas Jos _ 1 \ \ i y ` -- —_ r — TO J-1837 3-1100AL 21 KV IN 6" WHITE LANE Q J SCALE: 1"=a0' SCALE 1 1 4O' 0' 40' J-1259 j ,! /f �.^ 11 !?OAL 21 KY IN 6% TO J- 1226 HOA WATER— MH-11 1 KVA 9 10 11 12 13 14 15 11 8 100'/114' T-27808 Vi CD100 KVA 12 CUST 16 75'/89' 7 17 18 380'/407' cl ED J D Z_ n € 19 n 160'/174' i 12 6 r - m J 1 V 4 t SHEET E2 27 25'/40, 25•/40• 14 � ds 165'/180' , 13 1-----P E--P1---P1--Pi --Pt 12 �uu'lo.. 260'/297' 150'/165' 150'/165' 26 VD 5.9 FD 5.6 c! 1 1't •---Pt •---Pt L. a) 355'/392' 195'/213, 195'/210' VD 6.2 FD 6.1 25 j 24 16 25'/40' 25•/40' 5 8 ' 6 T-91928 180'/194' � 4' 7 100 KVA / 90'/104' 12 CUS f t)'/1 ' HELIOTROPE II COURT 23 s 15) /164. 150'/164' 22 21 150'/165' 150'/ 165' 20 130'/145' 19 1 VD 5.5 FD 6.3 50'/64' Q 3 N0. llrlllo H EET E2 14 / l f� l Q J SCALE: 1"=a0' SCALE 1 1 4O' 0' 40' J-1259 j ,! /f �.^ 11 !?OAL 21 KY IN 6% TO J- 1226 HOA WATER— MH-11 1 KVA 9 10 11 12 13 14 15 11 8 100'/114' T-27808 Vi CD100 KVA 12 CUST 16 75'/89' 7 17 18 380'/407' cl ED J D Z_ n € 19 n 160'/174' i 12 6 r - m J 1 V 4 t SHEET E2 27 25'/40, 25•/40• 14 � ds 165'/180' , 13 1-----P E--P1---P1--Pi --Pt 12 �uu'lo.. 260'/297' 150'/165' 150'/165' 26 VD 5.9 FD 5.6 c! 1 1't •---Pt •---Pt L. a) 355'/392' 195'/213, 195'/210' VD 6.2 FD 6.1 25 j 24 16 25'/40' 25•/40' 5 8 ' 6 T-91928 180'/194' � 4' 7 100 KVA / 90'/104' 12 CUS f t)'/1 ' HELIOTROPE II COURT 23 s 15) /164. 150'/164' 22 21 150'/165' 150'/ 165' 20 130'/145' 19 1 VD 5.5 FD 6.3 50'/64' Q 3 N0. llrlllo H EET E2 SHEET E3 j,6 29 t 28 115'/129' VD 5.9 380'/407' ` VD 2. .1 FD 5.7 t FD 3.11 T-44392 18 100 KVA 24 8 COST 4 2t tt s0'wCD /-_��=- J-72752 11 VOLTAGE DROP FIGURED ON PM 31115784 i TRACT 7246 PH 1 3 VD 5.0 129' 115' �—$V FD 5.9 / 12 SEE PM 31115797 FOR EXISTING TRACT 7254 30 31 2 C30 150/" 64' -'S1_ S1 _-s'?. 1 26 2 250'/287' 65'/79' 0 2 42 ,A o ` 13 Ir t cj 1 210'EXIST.( 60'/284' 831 o TIE INTO 4" N � liE INTO 2' r 75'EXIST. 4 o 245'/380' 802 14 J-74870 43 SEE PM 31115784 FOR EXISTING TRACT 7246 PH 1 38 f1 SEE PM 31096785 FOR EXISTING BACKBONE WORK 2" ._ / /� tN . �s£-° 3• 'PI, J-1 / 26 10 / 25 T -27807t 100 KVA KVA 10 COST 23 24 22 SEE PM 31115784 FOR EXISTING TRACT 7246 PH 1 27 _: �j ®� �- -� NZ / 1008KVA 678 21 10 COST 2 C� 42 37 30 LAUREN 41 -z* 32 33 W VD 2.9 FD 3.1 T-59373 100 90'/104 a CUSTA�i 90'/104'` 1 ---Si ----31 ,----51----�1 6 C�D 360'/374' 31 J V) 5.1 F) 5.7 .0 36 I 35 31 T--94237 100 KVA 9 CUST 32 WAY K� 36 COURT 65•/79' ^ VD 2.6 FD 2.7 39 34 33 m SHEET E%3 35 4th 155'/ 169' J 41 36 'f4Q VD 5.1 � FD 5.7 0y 37 C9� TEVI S 2102 CIR MAP 30264 PLAT, 3026131 INS DIST:B CLIMATE ZONE R VOLT � LASS 1 LOADING DIST: SI LIGHTNING DIST: 2 NON—CORROSIVE PCAE Pim Check does not relobe the, M—..� 8cm inl, m conxt da fad i Tics �t ax xx *Ag to PG&E gam. k Abe errs Of a couffut duft cmxEtut Liam ban wam PG&E St m dw* and *a plans, pQW Sim adords wQI col&OL FtedAonmwut• Mof. Ir1�e , SCALE: 1 "= 0' SCALE 40' 0' 40' 80' Na.nos= r arby; t ELECTRIC CONSTRUCTION SKETCH TRACT 7246 PHASE 2 RI D WWDBC; E WH ITE LANE AND BUENA VISTA W ro�rwoo�uoca�r�ccrwIotRi Illa,n Il*o�elma CAUFOMM t pwjw� � UT � California U ' 'ty Consultants Inc 7591 N Ave. Some 143 Fiewat CA 93711 Phow (559) 261-W Fax (559) 2619707 t WE2-16-MISSWr .. E3 OF 54 MIM t 103 � 0 0 2 42 ,A o ` 13 Ir t cj 1 210'EXIST.( 60'/284' 831 o TIE INTO 4" N � liE INTO 2' r 75'EXIST. 4 o 245'/380' 802 14 J-74870 43 SEE PM 31115784 FOR EXISTING TRACT 7246 PH 1 38 f1 SEE PM 31096785 FOR EXISTING BACKBONE WORK 2" ._ / /� tN . �s£-° 3• 'PI, J-1 / 26 10 / 25 T -27807t 100 KVA KVA 10 COST 23 24 22 SEE PM 31115784 FOR EXISTING TRACT 7246 PH 1 27 _: �j ®� �- -� NZ / 1008KVA 678 21 10 COST 2 C� 42 37 30 LAUREN 41 -z* 32 33 W VD 2.9 FD 3.1 T-59373 100 90'/104 a CUSTA�i 90'/104'` 1 ---Si ----31 ,----51----�1 6 C�D 360'/374' 31 J V) 5.1 F) 5.7 .0 36 I 35 31 T--94237 100 KVA 9 CUST 32 WAY K� 36 COURT 65•/79' ^ VD 2.6 FD 2.7 39 34 33 m SHEET E%3 35 4th 155'/ 169' J 41 36 'f4Q VD 5.1 � FD 5.7 0y 37 C9� TEVI S 2102 CIR MAP 30264 PLAT, 3026131 INS DIST:B CLIMATE ZONE R VOLT � LASS 1 LOADING DIST: SI LIGHTNING DIST: 2 NON—CORROSIVE PCAE Pim Check does not relobe the, M—..� 8cm inl, m conxt da fad i Tics �t ax xx *Ag to PG&E gam. k Abe errs Of a couffut duft cmxEtut Liam ban wam PG&E St m dw* and *a plans, pQW Sim adords wQI col&OL FtedAonmwut• Mof. Ir1�e , SCALE: 1 "= 0' SCALE 40' 0' 40' 80' Na.nos= arby; P E DMON SEWICES OA1ae (559) 641 2994 "325 WWlu Lame can (559) 760 9464 Alivmht�ee, CW fiornia 93601 ELECTRIC CONSTRUCTION SKETCH TRACT 7246 PHASE 2 RI D WWDBC; E WH ITE LANE AND BUENA VISTA W ro�rwoo�uoca�r�ccrwIotRi Illa,n Il*o�elma CAUFOMM eoo-ter- pwjw� � UT � California U ' 'ty Consultants Inc 7591 N Ave. Some 143 Fiewat CA 93711 Phow (559) 261-W Fax (559) 2619707 RULE 15, 16 31115789 NC 9 1 0961 2 82 4 WE2-16-MISSWr .. E3 OF 54 MIM SO" A A a: ee crr upw D WM caff lApa Spectrum 4 California Ave. Suite A leld, CA 93309 WHITE LN r 4 WE Ai -Z3X Lao in iiih 2 "1 t,,% , 0 , - — t L L GAZEBO CT M 1 ' -�'' 1�/7 HELIOTROPE CT U - z Ct r==te — — — i�� LEMONGRA55 CIRCLE vi ik VQD� 40, M ■Q 6 1 37 x z Z� 23 t2ta 13 12 1] 12 10 29 30 31 3? ]3 » 35 .� ow ' gyp• t .00 r LAUREN CT 1� 3 12 D 35 ' , ,p a2 41 .a 39 39 37 1 .3 VOO 13 t � 13 M CP vi --�T 15 14 36 35 34 moo 00 PW di .� �' �1 '� VINERY WY vow 73 f C} z# 31 32 f t OPOI �r '\ 210. f f t i 29 f f 1 LO► :14 C', CIA , kil -i 13 � .d n •ray 1T 12 10 r 0 ) ,a - ul L'. P k ;, 6 1 37 x z Z� 23 t2ta 13 12 1] 12 10 29 30 31 3? ]3 » 35 .� ow ' gyp• t .00 r LAUREN CT 1� 3 12 D 35 ' , ,p a2 41 .a 39 39 37 1 .3 VOO 13 t � 13 M CP vi --�T 15 14 36 35 34 moo 00 PW di .� �' �1 '� VINERY WY vow 73 f C} z# 31 32 f t OPOI �r '\ 210. f f t i 29 f f 1 LO► :14 C', CIA , kil -i 13 � .d n •ray 1T 12 10 r 0 ) ,a - ul L'. P k ;, 4 i � rr 4 �r de N OP J r le le le \j +" 0 r� r Vo M 14 op 00 s� oc► n� .r O r 1, rrrl rfrl fill rll�l r r Eel. fry rf�+ flll fill,. fl�l f ,.i� Dt ip ' I Iill +frirl CAMPUS PA13K OR r4I I II �Ilfl —=F I 4225 L a.. f .h ,r • 0 f