Loading...
HomeMy WebLinkAbout3.1-123 Record DrawingLIST Jl DRA WINGS SHEET I TI TLE SHEET SHEET 2 DETAILS SHEE T 3 P S TREE T — FROM MING AVE TO BELLE TERRACE CITY STANDARDS ST -72, ST -23, ST -24, ST -25, ST -26 ES— IA, A 88 — — ----- --- F.H. Fo-1 MANHOLE FIRE HYDRANT P.P. POWER POLE O M WATER METER W.V. EXIS TING MONUMEN T N WATER VALVE G. M. ❑ FU TORE MONUMEN T ® GA S ME TER S. L. G.V. STREET LIGHT N GAS VALVE STREET LIGHT W/MAST ARM -Q� BENCHMARK C.O. Q CLEAN OUT E- AU70 SCOPE FROM MING A VENUE AND BELLE TERRACE LOCATION MAP NOT TO SCALE PRE— EMP TION DEVICEJob No.: P51<223 File Path: S:\PROJECTS\2014-2015\P51<223 - St Light Imp - P Street\AutoCAD Drawings File Name: Street Light Improv P Street.dwg RE SACRAMENTO USAN FRANCISCO ®FRESNO CITY OO F BA ; ERSF'IELD LOS ANGELES SAN DIEGO STATE OF CALIFORNIA NO TE: THE CON TRA C TOR MUST POSSESS THE FOLL 0 WING VALID LICENSES: NO TE: THE CON TRA C TOR SHALL CONTACT THE USA L OCA TOR SERVICE 1-800-642-2444, 48 HOURS PRIOR TO EXCA VA TION. r QRpFESS/pNq S1NGy � C 80507 � * Exp. 3-31-17 C t v OF CAL \F 0.5 MILE 0 1 2 3 IN EA SEMEN T _ _ -� -� EXIST. CURB & GUTTER RIGH T— OF— WA Y EXIST. A.C. FL OWLINE CENTERLINE EXIST. EDGE OF PA VEMENT RAILROAD TRACKS GUARD RAIL - X CHAIN LINK FENCE IMPROVEMENTS -UTILITY SYMBOLS W EXIST WA TER LINE S EXIST SEWER LINE G EXIS T GAS LINE SD EXIS T S TORM DRAIN OH EXIST AERIAL E EXIST UNDERGROUND LINES POWER LINE TV EXIST UNDERGROUND T EXIST UNDERGROUND TV CABLES PHONE LINE 0 EXIST OIL LINE FO EXIST FIBER OPTIC LINE F.H. Fo-1 MANHOLE FIRE HYDRANT P.P. POWER POLE O M WATER METER W.V. EXIS TING MONUMEN T N WATER VALVE G. M. ❑ FU TORE MONUMEN T ® GA S ME TER S. L. G.V. STREET LIGHT N GAS VALVE STREET LIGHT W/MAST ARM -Q� BENCHMARK C.O. Q CLEAN OUT E- AU70 SCOPE FROM MING A VENUE AND BELLE TERRACE LOCATION MAP NOT TO SCALE PRE— EMP TION DEVICEJob No.: P51<223 File Path: S:\PROJECTS\2014-2015\P51<223 - St Light Imp - P Street\AutoCAD Drawings File Name: Street Light Improv P Street.dwg RE SACRAMENTO USAN FRANCISCO ®FRESNO CITY OO F BA ; ERSF'IELD LOS ANGELES SAN DIEGO STATE OF CALIFORNIA NO TE: THE CON TRA C TOR MUST POSSESS THE FOLL 0 WING VALID LICENSES: NO TE: THE CON TRA C TOR SHALL CONTACT THE USA L OCA TOR SERVICE 1-800-642-2444, 48 HOURS PRIOR TO EXCA VA TION. r QRpFESS/pNq S1NGy � C 80507 � * Exp. 3-31-17 C t v OF CAL \F 0.5 MILE 0 1 2 3 IN z 0 Q J U z Lu w V) rc w 2 0 J n 6"X6" r^^ot-DrTr APRON AR( 2" THICK MORTAR BED TO SEAL BOX BOTTOM 3/4" CRUSHED RO( UNDER BOX 8" THI( 3/4" PVC DRAIN TO GRAVEL 12� OLDCASTLE B1017 BOX (SEE NOTES) 18" MIN. RADIUS FOR CONDUITS EXTENDING TO PULL BOXES OR PG&E ##2 BOX INTERMEDIATE PULL BOX DETAIL NOT TO SCALE GENERAL NOTES: APPROVED LED MODEL ##: AEL AUTOBAHN 143W ATB2 40BLEDE10 MVOLT R2 NL P7 PCLL 1. POLES: TYPE 15-26' TALL, ROUND TAPERED, GALVANIZED POLE WITH 12' ELLIPTICAL MAST ARM o HAVING 24" ELEVATION FOR A 28' LUMINAIRE MOUNTING HEIGHT (DETAIL A/2) II TYPE 15S-18' TALL, ROUND TAPERED, GALVANIZED POLE WITH 12' ELLIPTICAL MAST ARM HAVING 24" ELEVATION FOR A 20' LUMINAIRE MOUNTING HEIGHT (DETAIL B/2) 4"X 6-1/2" HAND—HOLE COVER WITH 1/4" x 1-1/2" REINFORCEMENT RING WELDED TO Q OUTSIDE OF POLE, STEEL HAND HOLE COVER TO HAVE TWO 1/4-20 STAINLESS STEEL TAMPERPROOF HEX REJECT SCREWS N INSTALL HOT DIPPED GALVANIZED NUTS AND LEVELING WASHERS ON TOP AND BOTTOM OF C° FLANGE BASE. INSTALL GROUT UNDER BASE AFTER LEVELING. 00 BOLT CIRCLE 11", BOLTS ASTM A-307 1"x36%4" WITH HEX NUT, LEVELING NUT & TWO 0 WASHERS PER BOLT N 2. PULL BOX: °' BOX— OLDCASTLE B1017 OR APPROVED EQUAL WITH GALVANIZED STEEL SKID RESISTANT N a) BOLT DOWN LOCKING LID MARKED "STREET LIGHTS" c LOCATE PULL -BOXES AS INDICATED ON PLAN, MAXIMUM 2' FROM POLE BASE INSTALL 8" MINIMUM THICKNESS OF 3/4" CRUSHED ROCK UNDER BOX FOR DRAINAGE c �° INSTALL 2" MORTAR BED ON GRAVEL TO SEAL BOTTOM OF BOX INSTALL 3/4" PVC DRAIN PIPE TO ALLEVIATE STANDING WATER IN PULL BOX 3 1/2" X 8' COPPER CLAD GROUND RODS ARE REQUIRED IN BOXES FEEDING POLES ONLY—NOT IN INTERMEDIATE PULL BOXES a� 3. CONDUITS: co CONDUITS TO BE GRAY PVC SCHEDULE 40— 1-1/2" FROM POLE TO PULL BOX , USE 2" a- CONDUIT BETWEEN PULL BOXES ON LONG RUNS ° INSTALL CONDUITS SO THAT THEY ARE NEATLY ARRANGED IN CENTER PORTION OF BOX, 0 ENTERING BOX PLUMB 41 INSTALL END BELLS ON ALL CONDUITS -� SEAL CONDUITS WITH DUCT SEAL, COMPLETELY SEALING AROUND CONDUCTORS AND AT LEAST 1" THICK U) USE 18" RADIUS MINIMUM SWEEPS ON ALL BENDS -EXCEPTION STANDARD SWEEPS ARE OK � ON SHORT RUNS BETWEEN PULL BOX AND POLE 3 RUNS SHALL HAVE NO MORE THAN A TOTAL OF 270 DEGREES OF BENDS BETWEEN PULLING ° POINTS 0 o MINIMUM CONDUIT DEPTH SHALL BE 24" BELOW GRADE Q U 4. WIRING: REFER TO PLAN FOR WIRE SIZE IN EACH CONDUIT RUN Q MINIMUM CONDUCTOR SIZE IS ##10 THIN STRANDED COPPER IN NEW CONDUITS AND POLES, UNLESS OTHERWISE NOTED L V) USE BLACK FOR PHASE 'A' & RED FOR PHASE 'B' a SPLICES IN PULL BOXES SHALL BE MADE WITH STANDARD TIN PLATED UNISULATED I COMPRESSION SPLICES OR COPPER COMPRESSION PARALLEL SPLICE, INSULATE SPLICES WITH E HEAVY WALL ADHESIVE BASED HEAT SHRINK TUBING (3M 0400, 0800, 1100 OR APPROVED EQUAL), INSTALL 1.5" OF HEAT SHRINK PAST EACH END OF SPLICE, WHEN PARALLEL c SPLICES ARE MADE -INSTALL 3" OF HEAT SHRINK PAST EACH END OF SPLICE AND CRIMP J THE SPLICE WITH NEEDLE NOSE PLIERS UNTIL THE ADHESIVE HAS COOLED CREATING A WATER TIGHT SEAL AROUND EACH INDIVIDUAL CONDUCTOR. USE PROPER TOOLS TO MAKE 4_1 CRIMPS PER MANUFACTURES INSTRUCTIONS i GROUND WIRE FROM POLE BASE TO GROUND ROD SHALL BE ##8 MINIMUM N THE CIRCUIT SHALL BE FUSED IN THE PULL BOX ADJACENT TO THE POLE. FUSE HOLDERS ,Yn SHALL BE FERRAZ SHAWMUT FEX-11-11 600V 30A. INSTALL 3M 0400 HEAT SHRINK (OR n -APPROVED EQUAL) OVER TERMINATIONS WITH AT LEAST 1" OF HEAT SHRINK TUBING PAST � CONNECTION OVER CONDUCTOR INSULATION. 0 N FUSES SHALL BE 6A RATED — BUSSMAN KTK6—NO EXCEPTIONS d- 5. LUMINAIRES: jLUMINAIRES SHALL BE LED TYPE ONLY— REFER TO PLAN & DETAILS FOR FIXTURE TYPES INSTALL TORK 2007A TWISTLOCK PHOTOCELL ORIENTED NORTH w a 0 6. INSTALLATION: ALL WORK SHALL BE PERFORMED BY A LICENSED C10 ELECTRICAL CONTRACTOR UNDER JOURNEYMAN LEVEL SUPERVISION CITY OF BAKERSFIELD, CALIFORNIA MOUNTING HEIGHT NOTE: LIGHT POLES, ANCHOR BOLTS, MAST ARMS, AND LED FIXTURES WILL BE FURNISHED BY THE CITY OF BAKERSFIELD AND INSTALLED BY CONTRACTOR. (E) CURB & GUTTER (E) SIDEWALK (E) STREET , 12' APPROVED LED MODEL ##: AEL AUTOBAHN 143W ATB2 40BLEDE10 MVQLT R4 NL P7 PCLL STAINLESS STEEL TAMPERPROOF SCREW / HEX -REJECTION PIN STYLE �3/4" PVC DRAIN FUSE HOLDER OLDCASTLE B1017 BOX TO GRAVEL (SEE NOTES) 6x6 CLASS B CONCRETE -----APRON AROUND BOX d • � fTpe ..u..w ._* .e fik s ..� i ."A'°°" .'�..+.a w�.,.,.�..• • set • b R•i �p � 2..�-, . «d •; :b , 120 `aa 0 OR 01 FIELD CAST CLASS A CONCRETE PLACED AGAINST UNDISTURBED SOIL POLE AND PULL BOX DETAIL Im PUBLIC WORKS DEPARTMENT Nome. -Street Light Ir 5 No.: P5K223 te: Jun. 29, 15 • '' °• III--�I € I----1 11==I 11�-i (iI 1 !—! E E -=i I != 2" THICK MORTAR BED ,. TO SEAL BOX BOTTOM �r q« 3/4"CRUSHED ROCK UNDER BOX 8" THICK 8" MIN. RADIUS FOR CONDUITS EXTENDING TO PULL BOXES OR TRAFFIC SIGNAL BOX 2" 1/2 x 8 COPPER CLAD GROUND ROD TYPE 15 NOT TO SCALE P StreetDrawn: S CLA YTON Engineer: L SUN Checked By L. S MOUNTING HEIGHT NOTE: LIGHT POLES, ANCHOR BOLTS, MAST ARMS, AND LED FIXTURES WILL BE FURNISHED BY THE CITY OF BAKERSFIELD AND INSTALLED BY CONTRACTOR. 00ESS/pN9 51 NGlj c� F2 RE /S TERED Cl VIL ENGINEER C 80507rn * Exp. 3-31-17 CITY OF BAKERSFIELD llp�x CIVIL 1501 TRUXTUN AVENUE BAKERSFIELD, CA 93301 F OF CP,0F REVISIONS No. DA TE DESCRIP TION Eft� STAINLESS STEEL TAMPERPROOF SCREW HEX -REJECTION PIN STYLE 3/4" PVC DRAIN FUSE HOLDER OLDCASTLE, 61017 BOX 1'-6" TO GRAVEL (SEE NOTES) (E) CURB & GUTTER (E) SIDEWALK 6 x6 CLASS B CONCRETE I — I j —"APRON AROUND BOX (E) STREET =. -- -�-- 4 ' III—I i I-1 i 1=1 � I= I i►=1 I I --I i 1=1 i [= 2" THICK MORTAR BED ,. TO SEAL BOX BOTTOM 3/4 "CRUSHED ROCK UNDER BOX 8" THICK 18" MIN. RADIUS FOR CONDUITS EXTENDINGT 0 PULL BOXES 1�::t TRAFFIC SIGNAL BOX 2" 1/2" x 8' COPPER CLAD GROUND ROD ' 2'-6" 0 OR FIELD CAST CLASS A CONCRETE PLACED AGAINST UNDISTURBED SOIL B POLE AND PULL BOX DETAIL TYPE 75S 2 NOT TO SCALE STREET LIGHT IMPROVEMENTS P STREET FROM MING AVENUE AND BELLE TERRACE :3.1 - CITY RECORD No. Ic , j a3 SHEET NO. 2 OF 3 1 2 W? W 2 e � € €b s € B # # # # € € € € . ► -----w ---- ----- ---- 0 __-Qt=- 1A 2 ____ 1 -_ ___ __.__ ___ r 2 ",.. -- REPLACE EXISTING N30 TRAFFIC SIGNAL BOX WITH NEW OLDCASTLE B1 i/30 TRAFFIC RATED BOX AMD B1730— 51 JH LID. 112 ROUTE NEW STREET LIGHT CIRCUIT THROUGH EXISTING CONDUIT W _j B € INTO METER PLDESTAL AND INSTALL A NSW 2 POLE 30A CIRCUIT 1;=w € T T BREAKER ON WN—METERED PANEL SECTION. LABEL—"STREET h ;w LIGHTS P STRIfET". INSTALL 6X6 CONRETd SKIRT AROUND BOX. 1W J J #si Z O STA 12+03.24 - I ____ ---_ LL _......... __.______-� ._...._O-,-_._. ___ .__ _ 8�t- O� _�.94- W W _...... __ __.._._. z -i 1:0 3 _ _ ___ 4 _ ____ c» m _ _ _ _. . _ __. _�_� n w ----------- � t f w E-rIt F------------ I ~r_ U) I- O o0 Q 10 Z I\ Q O # U~i ? # V?'pf ESS/ pN� ► NG/&-/Fy EG/ S T RED l 71 -LEN INFER uJ C 80507 rn * Exp. 3-31-17 CITY OF BAKERSFIELD y Crv�� 1501 TRUXTUN A VENUE BAKERSFIELD, CA 93,301 F OF Cm - REVISIONS No. DA TE DESCRIPTION Q 114ALL STREET LIGHT C-0 #70674 1- �- _ _ _ wr � i si n as �y o � � ri . Lu w 21- 0 Lu NOT No co am 2 - ___._._ ,.. .. _.- ._- , � -. .�.,.._ . ,_ � _ - _ . p_ .._ _ , - .� � _._ _. .._ . . _.- % z _ £. + 0 13+00 14+Do 15+00 �6-too 17+00 _� '8-f-_ ___ --__ --_- __-w _ __ _ M -_-- -__ ___-f��Q� W d 5 _ _ D0 19-f-00 20 DD 21 ->FOD 22-�-DD Z cr-�° _. m.__w_. _ . _ .... U) T => a -B ___ ____ _ __ _-__ ___ �► -- - - __.__ -mm-- ___ _ _ , _..__.- A w-4-- __- __-_ ---- __ _ _ __ -- A __.. ---- u t z_j °__.M,.M_."µ.µ-i- �.w.vA 2 ___ _ _ _ _ _ __ _ 2 __ _ 6 ____ 2 7 2 8 ����=o < Q _ _ : a _ :w mow" nk _ ; _ :w,., �,._ __ _ -------------- --_� __ _ _ _— .. µ M - - _ M _ _ - v - _ _ _ _- _ _ .. , . _ _ _ _ .. _ _ ---- — — — — — — — — I- W ;;; -- - - - - - V=3 W y( Y.XX �:s-,.-��;` W 717 Cl) 0 N V) U w 0 fh n CONSTRUCTION NOTES 1� INSTALL NEW TYPE 15 POLE SINGLE ARM LIGHTING STANDARD WITH 143W LED. 2� INSTALL NEW TYPE 15S POLE SINGLE ARM LIGHTING STANDARD WITH 143W LED. �3 INSTALL OLDCASTLE B1017 TRAFFIC RATED PULL BOX AT LOCA TION AS SHOWN ON PLANS. CITY OF BAKERSFIELD, CALIFORNIA P STREET It. CONDUCTOR NOTES XX REFER TO CAL TRANS STANDARD PLAN 2010 ES -1A. DENOTES STANDARD NOTE AS APPLIED TO CONDUIT RUNS. CONDUITS DESIGNATED (N)EW or (E)XISTING REFER TO CONDUIT ONL Y. SCALE.- 1 If = 40' h`I I- 0 J It W N W O � CO Q h O cnU)� z # NOTE: LIGHT POLES, ANCHOR BOLTS AND LED FIXTURES WILL BE FURNISHED BY THE CITY OF BAKERSFIELD AND INSTALLED BY CONTRACTOR. INSTALL NEW 2" CONDUIT FROM NEW OLDCASTLE B1017 STREET LIGHT BOX TO EXISTING TRAFFIC SIGNAL PULL BOX. FEED STREET LIGHT CIRCUIT THROUGH EXISTING CONDUIT INTO METER PEDESTAL AND INSTALL A NEW 2 POLE 30A CIRCUIT BREAKER ON UN—METERED PANEL SECTION. LABEL --"STREET LIGHTS P STREET" CONDUCTOR SCHEDULE J 211 ---------------- 2" 211 2" 2" 21' 211 2" 2" W = EXISTING (N) = NEW N o Qom' ---- N N = 2 +00 24-1-00 UW oZ W V % CONDUCTOR RUN #8 THW CU GROUND F- 2 1 N W 5 0 6 0 O+ 8 1 9 1 10 1 I n 2 2 J 0 1 O to > 1 2 N J 2 + to ,J N J r - OQ a 1 Q V) of SEE "CONTROLLER DETAIL" Q Q 0 E Q c i ? # THIS SHEET I ? # w Z V LJOn 2 2 0 0 0 0 N V) U w 0 fh n CONSTRUCTION NOTES 1� INSTALL NEW TYPE 15 POLE SINGLE ARM LIGHTING STANDARD WITH 143W LED. 2� INSTALL NEW TYPE 15S POLE SINGLE ARM LIGHTING STANDARD WITH 143W LED. �3 INSTALL OLDCASTLE B1017 TRAFFIC RATED PULL BOX AT LOCA TION AS SHOWN ON PLANS. CITY OF BAKERSFIELD, CALIFORNIA P STREET It. CONDUCTOR NOTES XX REFER TO CAL TRANS STANDARD PLAN 2010 ES -1A. DENOTES STANDARD NOTE AS APPLIED TO CONDUIT RUNS. CONDUITS DESIGNATED (N)EW or (E)XISTING REFER TO CONDUIT ONL Y. SCALE.- 1 If = 40' h`I I- 0 J It W N W O � CO Q h O cnU)� z # NOTE: LIGHT POLES, ANCHOR BOLTS AND LED FIXTURES WILL BE FURNISHED BY THE CITY OF BAKERSFIELD AND INSTALLED BY CONTRACTOR. INSTALL NEW 2" CONDUIT FROM NEW OLDCASTLE B1017 STREET LIGHT BOX TO EXISTING TRAFFIC SIGNAL PULL BOX. FEED STREET LIGHT CIRCUIT THROUGH EXISTING CONDUIT INTO METER PEDESTAL AND INSTALL A NEW 2 POLE 30A CIRCUIT BREAKER ON UN—METERED PANEL SECTION. LABEL --"STREET LIGHTS P STREET" CONDUCTOR SCHEDULE J 211 2" 2" 211 2" 2" 21' 211 2" 2" O = EXISTING (N) = NEW N o Qom' ---- N Q = 2 +00 24-1-00 UW oZ _...__ Cr % CONDUCTOR RUN #8 THW CU GROUND 2 8co 2 1 uo�w 4 0 5 0 6 0 7 0 8 1 9 1 10 1 I #6 THW CU 2 2 1 0 0 1 E 0 0 1 2 2 _0 J 2 #10 THW CU GROUND N W -J 1 prj� 0 r Cl)+ 1 �' N 0 0 Q 0 #10 THW CU Q� N N 2 w Z V LJOn 2 2 0 0 0 0 0 0 N V) U w 0 fh n CONSTRUCTION NOTES 1� INSTALL NEW TYPE 15 POLE SINGLE ARM LIGHTING STANDARD WITH 143W LED. 2� INSTALL NEW TYPE 15S POLE SINGLE ARM LIGHTING STANDARD WITH 143W LED. �3 INSTALL OLDCASTLE B1017 TRAFFIC RATED PULL BOX AT LOCA TION AS SHOWN ON PLANS. CITY OF BAKERSFIELD, CALIFORNIA P STREET It. CONDUCTOR NOTES XX REFER TO CAL TRANS STANDARD PLAN 2010 ES -1A. DENOTES STANDARD NOTE AS APPLIED TO CONDUIT RUNS. CONDUITS DESIGNATED (N)EW or (E)XISTING REFER TO CONDUIT ONL Y. SCALE.- 1 If = 40' h`I I- 0 J It W N W O � CO Q h O cnU)� z # NOTE: LIGHT POLES, ANCHOR BOLTS AND LED FIXTURES WILL BE FURNISHED BY THE CITY OF BAKERSFIELD AND INSTALLED BY CONTRACTOR. INSTALL NEW 2" CONDUIT FROM NEW OLDCASTLE B1017 STREET LIGHT BOX TO EXISTING TRAFFIC SIGNAL PULL BOX. FEED STREET LIGHT CIRCUIT THROUGH EXISTING CONDUIT INTO METER PEDESTAL AND INSTALL A NEW 2 POLE 30A CIRCUIT BREAKER ON UN—METERED PANEL SECTION. LABEL --"STREET LIGHTS P STREET" CONDUCTOR SCHEDULE CONDUIT SIZE 211 2" 2" 211 2" 2" 21' 211 2" 2" 2" = EXISTING (N) = NEW N N N N N N N N N N N CONDUCTOR RUN #8 THW CU GROUND 1 I 2 1 3 0 4 0 5 0 6 0 7 0 8 1 9 1 10 1 11 I #6 THW CU 2 2 1 0 0 1 0 0 0 1 2 2 1 2 2 #10 THW CU GROUND 0 0 1 1 1 1 1 0 0 0 0 #10 THW CU 0 0 2 2 2 2 2 0 0 0 0 GENERAL NOTES 1. IF CONTRACTOR REMOVES EXISTING HANDICAP RAMP DURING CONSTRUCTION OPERATIONS, THE RAMP SHALL BE REPLACED WITH A NEW RAMP OF EQUAL TYPE WHICH MEETS CURRENT ADA SPECIFICATIONS 2. IF CONTRACTOR REMOVES EXISTING SIDEWALK, CURB, OR GUTTER DURING CONSTRUCTION OPERATIONS, THE IMPROVEMENTS SHALL BE REPLACED WITH NEIN IMPROVEMENTS OF EQUAL TYPE AND VALUE. J. CONNECT GROUND TO EXISTING 16 CU BARE AT SIGNAL PULL BOX. 4. OPEN TRENCH OR DIRECTIONAL BORING IS ACCEPTABLE. 5. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS PROVIDED AS BEST POSSIBLE_ FINAL RESPONSIBILITY OF VERIFICATION AND ACCURACY IS THE CONTRACTOR'S. 6. LIGHT POLES, ANCHOR BOLTS AND LED FIXTURES WILL BE FURNISHED BY THE CITY OF BAKERSFIELD AND INSTALLED BY CONTRACTOR. ALL OTHER BOXES, CONDUITS, CONDUCTORS, CIRCUIT BREAKERS, FUSES, FUSE HOLDERS, CONCRETE FOUNDATIONS, FORMED CONCRETE WORK, ASPHALT REPAIR, ETC. TO BE FURNISHED AND INSTALLED BY CONTRACTOR, File Nom Street Light Improv P Street PUBLIC WORKS DEPARTMENT Job No.: P5K223 Dote: Jun. 30, 15 Drawn: S CLAYTON Engineer: L SUN Checked By. _S C W W C:UHNCH (NOT TO SCALES (l/ I T RECORD N0. STREET LIGHT IMPROVEMENTS P STREET FROM MING AVENUE TO BELLE TERRACE SHEET NO. 3 OF 3 2 3