HomeMy WebLinkAboutinspection reports 2017BAKERSFIELD FIRE DEPARTMENT Prevention Services Division Underground Storage Tank Program 2101 H Street DW Inspection Repo tr Bakersfield, CA 93301 Permission to Inspect: Phone: 661 - 326 -3979 � Fax: 661- 852 -2171 J �S t,n . Business Name: ARCO #82765 -15- 021 - 097033 -J &J OIL GROUP, INC Date:02/21/2017 Address Name: 3333 Union Ave- CAL000397030 Inspector Name: Shane Gardner #8248557 Inspection Type: Routine Report: Final NVO = No Violation Observed OUT = Out of Compliance NA = Not Applicable UD = Undetermined COS = Corrected On Site RPT = Repeat Violation Violation Program Requirement o SOC Comments No vj Q a O a ago Z O Z M1 V pj File Review Facility Tank Information '2030021 Facility has a valid Permit Tank 1- 10000 -DW -REG to Operate from the Tank 2- 10000 -DW -REG CUPA - 23 CCR 16 2712(1); ® ❑ ❑ ❑ ❑ ❑ None Tank 3-1 0000-DW-M I D HSC 6.7 25284 Tank 4- 10000- DW -PRM 2010010 UST Operating Permit Application for Facility information and Tank information ® ❑ ❑ ❑ ❑ ❑ None submitted /maintained - 23 CCR 16 2711; HSC 6.7 25286(a) 2010001 Current BOE number submitted to the CUPA ® ❑ ❑ ❑ None and /or CERS - HSC 6.7 25286 c 2030011 UST compliance statement and /or Designated Operator ❑ ® ❑ ❑ ❑ ❑ None current certification submitted - 23 CCR 16 2715(a), 2715(b 2030046 A complete and accurate response plan has been submitted, approved and ® ❑ R ❑ ❑ None maintained - 23 CCR 16 2632, 2634(e), 2641(h), 2712(1) 2030041 A complete and accurate plot plan has been submitted, approved and ® ❑ ❑ ❑ ❑ ❑ Minor maintained - 23 CCR 16 2632(d )(1 (C ), 2711(a)(8) 2010006 Owner /Operator has not made false statements or representation on any ® ❑ ❑ ❑ ❑ ❑ None required document - HSC 6.7 25299 2010003 Owner /Operator has a DO and /or informed the CUPA of any change (s) ® ❑ ❑ ❑ El [] None within 30 days - 23 CCR 16 2715(a) Violation Program Requirement o SOC Comments No O �-o z o z _ v o> Testing 2030002 Owner /Operator has tested and certified leak ❑ ❑ ❑ ❑ ❑ None detection equipment annual) - 23 CCR 16 2638 2030048 Secondary containment testing conducted every 36 months in accordance ® ❑ ❑ ❑ ❑ ❑ None with requirements - 23 CCR 16 2637 2030055 Spill buckets have been tested annually as ® ❑ ❑ ❑ ❑ ❑ None required - HSC 6.7 25284.2 2010009 Secondary containment test results submitted to the CUPA within 30 days ® ❑ ❑ ❑ ❑ ❑ None after the test - 23 CCR 16 2637(e) 2030064 CUPA was poperly notified within the prescribed number of ® ❑ ❑ ❑ ❑ ❑ None hours prior to testing - 23 CCR 16 26370, 2638(e), 2643(8), 2644.1(a)(4) Install /Repair 2060009 Permits obtained to install, replace, repair, or ® ❑ ❑ ❑ ❑ ❑ None modify part of the UST system - 23 CCR 16 2712 UST System Observation General Monitoring 2030003 Leak detection system maintains continuous RD monitoring that activates ® ❑ ❑ ❑ ❑ ❑ None ❑ an audible and visual Yes alarm - 23 CCR 16 2632, 2634, 2636, 2666 2030016 The annular space of the tank, piping and sumps RD are continuously monitored and activates ® ❑ ❑ ❑ ❑ ❑ None ❑ the alarm - 23 CCR 16 Yes 2631(g), 2632(c)(2)(A) &(8), 2633(c), 2636 2030017 Product piping outside the UDC is fail -safe and shuts down the pump or ® ❑ ❑ ❑ ❑ ❑ None restricts flow - 23 CCR 16 2636(0 (5) 2030018 Turbine sump monitor RD activates an audible and visual alarm or stops the ® ❑ ❑ ❑ ❑ ❑ None ❑ flow of at the dispenser - Yes 23 CCR 16 26360(1) Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement d o SOC Comments No O = a o o (L a)c z o z M )!; 2030019 Monitoring system in the UDCs activates an audible and visual alarm ® ❑ ❑ ❑ ❑ ❑ None or stops the flow at the UDC -23 CCR 16 2636 (0(1) 2030043 Leak detection equipment RD properly programmed or properly operated - 23 ® ❑ ❑ ❑ ❑ ❑ None ❑ CCR 16 2632, 2634, 2636, Yes 2666 2060005 System constructed with a monitoring system capable of detecting entry ® 0 ❑ ❑ None into secondary containment - HSC 6.7 25291(b 2060014 Correct leak detection equipment installed for RD the type of system ® ❑ ❑ ❑ El ❑ None ❑ present - 23 CCR 16 2638, Yes HSC 6.7 25290.1, 25290.2, 25291 2060015 Sensor located in the RD proper position /location - None ❑ 23 CCR 16 2630(d), 2641(a) Yes 2030062 Facility is in compliance RD with not tampering with or disabling leak detection ® ❑ ❑ ❑ ❑ ❑ None ❑ devices or alarms - HSC Yes 6.7 25299 a (9) 2060022 System constructed with a monitoring system capable of detecting entry ® ❑ ❑ ❑ ❑ [] None into secondary containment - HSC 6.7 25290.2(d) 2030034 Tag /sticker on affixed monitoring equipment being certified, repaired, ® ❑ El ❑ ❑ ❑ None or replaced - 23 CCR 16 2638( VPH Monitoring VPH 2030065 Interstitial monitoring of RD the annular spaces of the UST is properly ❑ ❑ ® ❑ ❑ ❑ None [:1 maintained - HSC 6.7 Yes 25290.1(e 2060023 System constructed with a monitoring system capable of detecting entry into secondary ❑ ❑ ® ❑ ❑ ❑ None containment - HSC 6.7 25290.1(d) Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement d .o SOC Comments No O 1- ( � c z z o ° o> Line Leak Detector 2060012 Line leak detector installed on pressurized RD piping system - HSC 6.7 ® ❑ ❑ ❑ ❑ ❑ None ❑ 25290.1(h), 25290.2(8), Yes 252910, 25292(e), 26360(2) 2030026 Line leak detectors detect a 3 gph leak and /or RD audible and visual alarm ® ❑ ❑ ❑ ❑ ❑ None ❑ function properly - 23 Yes CCR 16 2636(0(6), 2666(c) 2030027 Turbine shuts down when RD a leak is detected or when line leak detector is ❑ ❑ ® ❑ ❑ ❑ None ❑ disconnected - 23 CCR 16 Yes 2666 c 2030025 Pressurized piping able to detect a 3.0 gph leak RD within an hour, and ® ❑ ❑ ❑ ❑ ❑ None ❑ restricts the flow or Yes alarms - 23 CCR 16 2636(1) (2) Secondary Containment 2060010 UST storing a hazardous RD substance has secondary ® ❑ ❑ ❑ ❑ ❑ None ❑ containment - HSC 6.7 Yes 25292 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement o SOC Comments No O Nc Z O z � 0 � o 2030008 UDC, sumps, and /or other secondary containment in good ® ❑ ❑ ❑ ❑ ❑ None condition and /or are free of debris /liquid - HSC 6.7 25290.1, 25290.2, 25291 2030040 Secondarily contained RD piping maintained to allow ® ❑ ❑ ❑ ❑ ❑ None ❑ liquid to drain into sump - Yes 23 CCR 16 2630(d), 2641(a) 2060006 Secondary containment piping slopes back to the ® ❑ ❑ ❑ ❑ ❑ None collection sump - 23 CCR 16 263(c) 2030047 Secondary containment maintained tight and has been confirmed by testing ® ❑ ❑ ❑ ❑ ❑ None - 23 CCR 16 2662, HSC 6.7 25290.1(c)(2), 25290.2(c)(2), 25291(a), 25292(g) 2030060 Entry fittings in secondary containment for UST system maintained ® ❑ ❑ ❑ ❑ ❑ None tight/sealed - 23 CCR 16 2630, 2635(d), 2636(c), 2666 2060020 Spill bucket is installed RP and has a functional drain valve or other means to ® ❑ ❑ ❑ ❑ ❑ None ❑ remove liquid - 23 CCR 16 Yes 2635(b), 2665 2030054 Spill bucket maintained in RP good condition and free of ® ❑ ❑ ❑ ❑ ❑ None ❑ debris and /or liquid - 23 Yes CCR 16 2635(b), 2715(c)(2) 2060019 Spill bucket to has a minimum capacity of five ® ❑ ❑ ❑ ❑ ❑ None gallons - 23 CCR 16 2635(b), 2665 Overfill 2030035 UST system is operated RP to prevent unauthorized release, including spills ® ❑ ❑ ❑ ❑ ❑ None ❑ and overfills - HSC 6.7 Yes 25292.1 a 2030036 Overfill prevention system RP has not been overridden and meets overfill ® ❑ ❑ ❑ ❑ ❑ None ❑ requirements - 23 CCR 16 Yes 2635(b)(2), 2665 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement 0 o SOC Comments - No O = Q o 0 c~..c z O z I M 0 w W> On Site Records Certifications 2030023 Required designated operators or contractors maintain a proper and ® ❑ ❑ ❑ ❑ ❑ None current ICC certification - 23 CCR 16 2715 2030024 Service technician, installer, and/ or employee maintain a ® ❑ ❑ ❑ ❑ ❑ None proper license - 23 CCR 162715 2030031 Employee or contractor obtained and maintained proper manufacturer ® ❑ ❑ ❑ ❑ ❑ None certification - 23 CCR 16 2715 2010007 Submit/maintain current Certificate of Financial Responsibility /mechanism of financial assurance - ❑ ❑ ❑ ❑ ❑ None 23 CCR 16 2711; 23 CCR 18 2808.1, 2809- 2809.2, HSC 6.7 25292.2; HSC 6.75 25299.30- 25299.34 Designated Operator 2010004 Copies of DO inspections for last 12 months and list of trained employees ® ❑ ❑ ❑ ❑ ❑ None maintained - 23 CCR 16 2715 2030013 Designated operator properly conducted the monthly inspection and ® ❑ ❑ ❑ ❑ ❑ None the reports are complete - 23 CCR 16 2715 2030010 DO notified operator of any condition observed during the monthly ® ❑ ❑ ❑ ❑ ❑ None inspection that may require action - 23 CCR 16 2715(d 2030012 DO employee training performed, current for at least one employee on ® ❑ ❑ ❑ ❑ ❑ None site, and a log kept - 23 CCR 16 2715(c)(6), 27150 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement W. d o' SOC Comments No o _ d o o a Cc Z o z M 0 W o> Logs 2030001 Leak detection alarm logs, maintenance and RD records of appropriate 0 ❑ ❑ ❑ ❑ ❑ None ❑ follow -up actions Yes maintained - 23 CCR 16 2632, 2634, 2712(b) Maintenance/Tests 2010008 Monitoring, maintenance, repairs, linings, and RD upgrade records ® ❑ ❑ ❑ ❑ None, ❑ maintained for the proper Yes time period - 23 CCR 16 2712(b) Documentation 2030033 Failure to maintain on site an approved monitoring ❑ ® ❑ ❑ ❑ ❑ None plan - 23 CCR 16 2632, 2634, 2711, 2712(1) 2030037 Written agreement between the tank owner and tank operator to monitor the tank system ® ❑ ❑ ❑ ❑ ❑ -None is maintained - 23 CCR 16 2620(b); HSC 6.7 25284(a)(3) 2030061 Suspected or actual RD unauthorized release reported in appropriate ❑ ❑ ® ❑ ❑ ❑ None ❑ time frame - HSC 6.7 Yes 29294, 29295 General Operating Requirements Permit Condition /Approval 2030039 Compliance with all operating permit ® ❑ ❑ ❑ ❑ ❑ None conditions - 23 CCR 16 2712, HSC 6.7 25299 2030059 UST system maintained in accordance with exclusion /exemption ® ❑ ❑ ❑ ❑ ❑ None status - HSC 6.7 25281.6, 25283.5 2030014 Owner /Operator received approval and has implemented a training ❑ ❑ ® ❑ ❑ ❑ None program at an unstaffed facility - 23 CCR 16 2715( 2) 2030015 Facility exhibited that the method used to monitor the tank meets the monitoring methods in ® ❑ ❑ ❑ ❑ ❑ None 2643(f) - 23 CCR 16 2643 Underground Storage Tank Program - DW Inspection Report v L.0 Violation Program Requirement 4- 0 .2 0 SOC Comments No OO D a 0 0. 4.0 Co cc 0 z 0 z D 0 W Red Tag 2030045 Red Tag information is legible and has not been ❑ None tampered with - 23 CCR 16 2717.1 (g) 2030044 Facility did not allow for deposit of petroleum into a UST that has a red tag ❑ ❑ None affixed to the fill - 23 CCR 162717.1(0 Install/Repair 2060024 UST system is made of or lined with materials that are compatible with the None substance stored - 23 CCR 16 2631.1 2060021 Striker plate installed and positioned correctly - 23 None CCR 16 2631(g), 2662(d) ❑ There were no violations noted for this inspection. ZThis report shall serve as a "NOTICE TO COMPLY" for Minor Violations, and a "NOTICE OF VIOLATION" for Major violations. You are, hereby, ordered to correct the above noted violations within 30 days, or according to correction summaries provided. Formal enforcement and/or penalty assessment may be initiated for any violations noted, and for those not corrected in a timely manner. (NOTE: If this is a preliminary report, a final report will follow.) Inspectors Signature: Date Inspector: Enter # of Violations: RD: CD RP: Check one box for facility Significant Operational Status (SOC) to be reported to SWRCB and US EPA: ❑SOC with both Release Detection and Release Detection (Facility has no Release Prevention and no Release "Prevention Violations) ❑ Not in SOC (Facility has both Release Prevention and Release Detection Violations) ❑SOC with Release Detection only (Facility has no Release Detection violations but one or more Release Prevention violations) ❑ SOC with Release Prevention only (Facility has no Release Prevention violations but one or more Release Detection violations) Underground Storage Tank Program - DW Inspection Report v 2.0 FACILITY CERS Violation INSPECTION DATE INSPECTION TIME NAME ADD'RESS 3010001 PHONE NO. NO OF EMPLOYEES " AJ 1n 1010008 FACILITY CONTACT BUSINESS ID NUMBER rc?z C73 Consent to Inspect Namefritle . VISIBLE ADDRESS (CFC: 505.1, BMC: 15.52.020) F rx`C. P "^ti w � Y �... c• r , N ,,.. b: tce'e. ,3 k v''�..a .. {. .... ... :'.r.,,.:i` <. . .h ,.x.. '�y f � , ..0 :., ..N'. > .,. .. �s.. 't z. y "�' .." .: >.r.. ,t ,^>•<, � .�xk. ua "k ' '� �;. �. � Y �3'w r , .. ��s Y. { .,zr �. n:< �. %' ni .3... . - . .� �:. .. 7 ..... -. .. ; ,: ; ;.. c: y • . ,.:x„r,+ o <- .�* a � .A:. y �`,�". Y: .._:w`:�ry ��7c0�F..C, F,:.. '?2�,::.��,?:3,'�Y.� ,Y:e� :fo.; ',.. �:.n:.:,, $ <: r.hf�s'..:.:. x a,.. ur �x �,., u3..z.k iiwE, Lt.:;✓Aaw.�Gre t,e4 SSa. Y, kr".Y,a l�h......m 'Y,4 {k�..2+::C.: -._ na_ r..,Tf.AZ.,fcf,Cc+..��?rl. ,,m,,,�a.e s..: s&eF'..S „...Y,.:..T�'�..:#. .....:,�.�_.,. 9a'f x..,J�rP..'is,''El ,r....?s:. „$, s,er.., aYJ".' ❑ ROUTINE COMBINED ❑ JOINTAGENCY_ ❑ MULTI- AGENCY ❑ COMPLAINT ❑ RE- INSPECTION omp lance C V OPERATION v =violation; 1,11 Minor CERS Violation COMMENT APPROPRIATE PERMIT ON HAND (BMC: 15.65.080). 3010001 BUSINESS. PLAN CONTACT INFORMATION ACCURATE (CCR: 2729.1) 1010008 VISIBLE ADDRESS (CFC: 505.1, BMC: 15.52.020) CORRECT OCCUPANCY (CBC: 401) VERIFICATION OF INVENTORY MATERIALS (CCR: 2729.3) 1010004 VERIFICATION OF QUANTITIES (CCR: 2729.4) 1010006 VERIFICATION OF LOCATION (CCR: 2729.2) PROPER SEGREGATION OF MATERIAL, (CFC: 2704.1) VERIFICATION OF SDS AVAILABILITY (CCR: 2729.2(3)(b)) VERIFICATION OF HAZ MAT TRAINING (CCR: 2732) 1020002 VERIFICATION OF ABATEMENT SUPPLIES & PROCEDURES (CCR: 2731(c)) EMERGENCY PROCEDURES ADEQUATE (CCR: 2731) 1010010 t CONTAINERS PROPERLY LABELED (CCR: 66262.34(f), CFC: 2703.5) 3030007 HOUSEKEEPING (CFC: 304.1) FIRE PROTECTION (CFC: 903 & 906) 3030032 SITE DIAGRAM ADEQUATE & ON HAND (CCR: 2729.2) 1010005 ANY HAZARDOUS WASTE ON SITE? El ,NO Signature of Recei t �. " ' C k ` . -- Explain: Inspector: POST INSPECTION INSTRUCTIONS • Correct the violation(s) noted above by • Within 5 days of correcting all of the violations, sign and return a copy of this page to: Signature (that all violations have been corrected as noted) Bakersfield Fire Dept., Prevention Services, 2101 H Street, California 93301 Date White - Business Copy Yellow - Station Copy Pink Prevention Services FD2155 (Rev 8//14) , HAZARDOUS WASTE BAKERSFIELD FIRE DEPARTMENT UNIFIED PROGRAM CONSOLIDATED FORMS °'` Prevention Services H ERSFI i.D 2101HStreet SMALL QUANTITY HAZARDOUS �'�� Bakersfield, CA 93301 WASTE GENERATOR INSPECTION ARTM Phone: 661 - 326 -3979 • Fax: 661 -852 -2171 Facility Name: ! , Date: Site Address: ��, a t "t Time In: Time Out: Owner /Operator: r"" +" t~l Phone: EPA ID # pe of Inspection 0 Routine 0 Re- inspection/Follow -up >Cclombined Routine 5pection -0 Joint Insp 'on 0 Complaint 0 Focused d Other YCONSENT TO INSPECT GRANTED BY (Name/ Title): Inspection may involve obtaining photographs, review and copying of records, and determination of compliance with hazardous waste handling requirements. \„ = C %-Ulll V I 141111.. V — '%-Maa 1, as va .Tua.w HAZARDOUS WASTE REQUIREMENT N/A CERS Violation # COMMENTS Recordkee in documentation Generator has an EPA ID number HSC 25143.131 3010002 Hazardous waste determination made for all wastes n Anal sis )!Penerator Knowledge [CCR 66262.401 3030005 Contingency lan information posted near one [CCR 66262.34(d)(2)] 3010022 Facility personnel demonstrate training/awareness [CCR 66262.34(d)(2)] 3020001 " Manifests/Consolidated Manifest receipts complete [CCR 66262.23(a)] 3010008 Blue co (s) of manifest mailed to DTSC [CCR 66262.23(a)(4)] 3010011, Bills of Lading/receipts available [CCR 66262.40(a)] 3010010 LDRs available and complete CCR 66268.7(a)] 3030006 Onsite recyclink reported using UPCF [HSC 25143.101 3030001 Container /tank management Containers are in good condition CCR 66262.34(d)(2)] 3030013 . Containers are closed except when adding/removing [CCR66262.34(d)(2)] 3030017 Satellite containers at or near point of generation [CCR 66262.34(e) 1)(A)] Empty containers are empty [CCR 66262.34(f)] 3030007 Containers inspected weekly [CCR 66262.34(d)(2)] 3030019 Tanks inspected daily CCR 66262.34 d 2 , 40CFR 265.2011 1 3030027 One container per waste stream at satellite area CCR 66262.34 d 2 3030022 Exclude recyclable materials stored in accordance with local ordinance/hazardous materials codes [HSC 25143.101 3010016 Accumnf ation Time Limits Waste is accumulated not more than 90180 0 CCR 66262.34(d)] 3030010 Empty containers managed within one y ear CCR 66262.34(d)] [ 3030010 Universal waste accumulated less than one year [CCR 66273.15(a)] 3030011 Used oil filters offsite within 180 (1 year <1 ton) [CCR 66266.130(c)(4)] 3030004 Pb -acid batteries offsite within 180 (1 yr. < 1 ton) [CCR66266.81(a)(3)] 3030002 Labeling/Marking Containers are properly labeled [66262.34(f)] 3030007 Excluded recyclable materials marked properly. [HSC.25143.9(a)] 3050005 Universal waste container properly labeled (CCR 66273.341 3030008 Used oil filters marked "drained used oil filters" [CCR 66266.1301 3030004 Date written on spent lead -acid batteries [CCR 66266.81(a)(6 )(B)] 3030003 "Used Oil" marked on all used oil tanks /containers [CCR 66279.21 3030007 Tank marked with "haz waste" , contents, start date 66262.34 f)] 3030007 Treatment,_ Transport and Disposal/Other Have ermit/authorization to do treatment [HSC 25136.21 3040003 Waste sent with authorized transport (gen. eligible) [CCR 66263.41] 3050001 Waste disposed of to authorized point/ party [HSC 25189.5(a)] 3050002 Failed to properly handle appliance wastes fHSC 25212(a) Fire Protection [66262.34(d)(2)] 3030032 Print and sign in this box for receipt of this report. Signature does not imply agreement with findings only receipt of report. V� k INSPECTOR " POST INSPECTION INSTRUCTIONS: * Correct the violation(s) noted above by • Within 5 days of correcting all of the violations, sign and return a copy of this page to: Bakersfield Fire Dept., Prevention Services, 2101 H St. Bakersfield, CA 93301 White — Business Copy Yellow— Station Copy Signature (that all violations have been corrected as noted) Date FD2171 .(Rev 9/14) Pink- Prevention Services Copy K�� Owner /Operator: - - r; Facility:i - Address: INJI There were NO violations observed during this inspection ♦...a � u .... r -5,. v:W � ?'b'R � < k n �zce`',' ,... u . a :.' ,. e., .-„ W ,,. S.. ,. . �. ' � tk4'Y- ' .. „:�`- �.� +"g�,,c -,. T 1 � „a�,r. �� ai. �.... -.. tai. . ✓ Notice to Comply: Minor Violations were found Bunn this ins ecfii'on as noted in the following Su►nma of Viola #ions. The violations indicated in this` inspection report must be corrected within 30 days, unless otherwise noted. F ormal- enforce�ment-may.be initiated for any violations noted, and for those snot corrected in a ` timely manner. This report does' not represent that there are 'no other violation at this facility. A re- inspection may occur to determine compliance status. Al IMMARY nF VIOLATIONS ^c®-irrcrr+nirt'r % ki r%C.DCT1.IPKI T(I r'C)MPI IANr'_F certify that the violations noted above on this. - Notice to Comply /s,umm.ary of Violations have been corrected. I have personally examined any documentation "attached to the certification to establish that the violations have been corrected. Signature; Title: Print Name: Date: KPS #8446 V- 11^%.. -Pi icinccc rrnnv fn nP Gent in after Return -to- Compliance Pink - Prevention Services Copy