HomeMy WebLinkAboutORD NO 3030ORDINANCE NO. 3030 NEW SERIES
AN ORDINANCE OF THE COUNCIL OF THE CITY OF
BAKERSFIELD AMENDING SECTIONS 15.28.010,
15.28.020, 15.28.030, 15.28.040, 15.28.050,
15.28.055, 15.28.060, 15.28.070 and 15.28.080,
OF THE BAKERSFIELD MUNICIPAL CODE REGARDING THE
UNIFORM PLUMBING CODE.
BE IT ORDAINED by the Council of the City of Bakersfield
as follows:
Section
hereby amended to
SECTION 1
15.28.010 of the Bakersfield Municipal
read as follows
Code is
15.28.010 Adoption.
Except as otherwise provided
tain plumbing code known and designated
in this chapter, that cer-
as the Uniform Plumbing
Code, 1985 Edition, (with Appendices A through I), sponsored and
copyrighted by the International Association of Plumbing and
Mechanical Officials, three copies of which have heretofore been
filed with the City Clerk of the City for use and examination by
the public, is adopted by reference and enacted as the plumbing
code of the City for the purpose stated therein.
Section
hereby amended to
SECTION 2
15.28.020 of the Bakersfield Municipal
read as follows:
Code is
15.28.020 Modifications.
The sections of the Uniform Plumbing Code, 1985 Edition,
-1-
mentioned
reference,
15.28.090.
in Sections 15.28.030 through 15.28.090,
are modified and amended as provided in
as adopted by
Sections
hereby
SECTION 3
Section 15.28.030 of the Bakersfield Municipal Code
amended to read as follows:
15.28.030 Section 609 amended - Cooling Water.
Section 609 is amended to read as follows:
609 (a) Water which has been used as a cooling medium in
any cooler, appliance, device or other apparatus shall not be con-
nected to the drainage system on the premises where the cooler,
appliance, device or other apparatus is located and used, nor
shall the water be in any manner discharged into the sanitary
sewer system of the City of Bakersfield, provided, however, that
water which has been used as a cooling medium in any cooler,
appliance, device or other apparatus must be disposed of in a man-
ner approved by the Building Director of the City of Bakersfield.
(b) All connections heretofore made or existing at the
time of the effective date of the ordinance codified herein, as
mentioned in this section, shall be disconnected from the sanitary
sewer system of the City of Bakersfield, and the discharge of
water from the coolers, appliances, devices and other apparatus
shall be effected in a manner approved by the Building Director.
-2-
15.28.040
follows:
Section
hereby amended to
Section 903
Section 903
SECTION 4
amended - Overflows.
is amended by adding a paragraph as
Overflows are required on all bathtub installations.
SECTION 5
15.28.050 of the Bakersfield Municipal Code is
read as follows:
15.28.050 Section 1004 (a) Materials - PB & CPVC pipe deletion.
Delete the sentence in paragraph (a) which allows the
use of PB and CPVC water pipe or tubing within a building.
hereby
Section
amended to
SECTION 6
15.28.055 of the Bakersfield Municipal Code
read as follows:
is
15.28.055 Section 1101 (d) Sewer required.
Section 1101 (d) is amended to read as follows:
1101 (d) The public sewer may be considered as not
being available when such public sewer or any building or any
exterior drainage facility connected thereto, is located more than
one thousand (1,000) feet from the nearest property line of any
proposed building or exterior drainage facility on any lot or pre-
mises which abuts and is served by such public sewer.
EXCEPTIONS: 1) The above requirement may be reduced to two
hundred (200) feet if the proposed development is for residential
living units and is four units or less.
-3-
2) The requirements may be waived or modified
by the Building Official when strict compliance may cause extreme
hardship.
Section
hereby amended to
15.28.060 Section 1008
SECTION 7
15.28.060 of the Bakersfield Municipal
read as follows:
(c) amended Installation,
Code is
inspection
and testing.
Section 1008 (c) is amended to read as follows:
1008 (c) No water piping shall be installed within a
concrete slab or in the ground under a concrete slab of a
building.
EXCEPTIONS: If required by structural conditions, water pip-
ing may
by an approved pipe wrapping material with the prior approval
be installed in chases, sleeves, ducts or may be protected
of
in accordance with the following
shall have a protective coating of
recognized
protection and
the administrative authority
requirements:
(1) Ferrous piping
an approved
standards.
type, machine applied and conforming to
Field wrapping shall provide equivalent
is restricted to those short sections
stripped for threading. Zinc coating
deemed adequate protection for piping
(2) Copper tubing shall be
and fittings necessarily
(galvanized) shall not be
or fittings.
protected per paragraph
and shall be installed without joints where possible. Where
joints are permitted, they shall be brazed, and fittings shall
wrought copper.
-4-
(1)
be
Section
hereby amended to
SECTION 8
15.28.070 of the Bakersfield Municipal
read as follows:
15.28.070 Section 1208 Authority to Render Gas
Addition.
Add a new paragraph (c) to
approved inspection(s) is required before
poration authorized in paragraph (a)
the gas service described except for
purposes.
Code is
Service
read: A permit and
the person, firm or cor-
above turns on or reconnects
emergency and maintenance
Section
hereby amended to
SECTION 9
15.28.080 of the Bakersfield Municipal
read as follows:
Code is
15.28.080 Section 1310 Water Heater Protection From Damage -
Addition.
Add a new paragraph (e) to read: Where a water
heating appliance is placed above in living space in a hidden
location or where structural damage may result from such hidden
appliance from deterioration or failure, a corrosion resistant,
water-tight, metal pan with an appropriately sized drain line ter-
minating outside the building or to an approved receptor shall be
installed beneath the appliance.
SECTION I0
This Ordinance shall be posted in accordance with the
City Charter provisions and shall become effective thirty (30)
days from and after the date of its passage.
.......... 000 ..........
-5-
I HEREBY CERTIFY that the foregoing Ordinance was passed
and adopted by the Council of the City of Bakersfield at a regular
meeting thereof held on the 7th day of May , 19 86 , by
the following vote:
ABSENT. COUNCILMEM"ERS ~0
A6STAINING: COU~CILMEM~ERS ~
CITY CLERR and Ex Officio Clerk of
Council of the City of Bakersfield
the
APPROVED this 7th day of May , 19 86
MAYOR of the City of Bakersfield
APPROVED as to form:
Y,~rTORNEY ~ the City of Bakersfield
-6-
A, ffiilaut! ostmg rhman es
STAT~ OF CALIFORNIAt ss.
County of Kern ·
CAROL WILLIAMS, Being duly sworn, deposes and says:
That she is the duly appointed, acting and qualified City Clerk of the City of Bakersfield; and
that on May 14 , 19 86 , she posted on the Bulletin Board
at the City Hall, a full, true and correct copy of an ordinance passed by the Council of said City
at a meeting thereof duly held on blay 7 , 19 86 , which ordinance
was numbered 3030 New Series, and entitled:
AN ORDINANCE OF THE COUNCIL OF THE CITY OF
BAKERSFIELD AMENDING SECTIONS 15.28.010,
15.28.020, 15.28.030, 15.28.040, 15.28.050,
15.28.055, 15.28.060, 15.28.070, 15.28.080,
OF THE BAKERSFIELD MUNICIPAL CODE REGARDING
THE UNIFORM PLUMBING CODE~
City Clerk
Subscribed and sworn to before me this