HomeMy WebLinkAboutFMC 2017MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of CaliforniaAuthority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A. General Information Facility Name:Bldg. No.: Site Address: City: Zip: Facility Contact Person: Contact Phone No.: Make/Model of Monitoring System: Date of Testing/Servicing: B. Inventory of Equipment Tested/Certified Check the appropriate boxes to indicate specific equipment inspected/serviced: Tank ID:Tank ID: In-Tank Gauging Probe. Model:In-Tank Gauging Probe. Model: Annular Space or Vault Sensor. Model:Annular Space or Vault Sensor. Model: Piping Sump / Trench Sensor(s). Model:Piping Sump / Trench Sensor(s). Model: Fill Sump Sensor(s). Model:Fill Sump Sensor(s). Model: Mechanical Line Leak Detector. Model:Mechanical Line Leak Detector. Model: Electronic Line Leak Detector. Model:Electronic Line Leak Detector. Model: Tank Overfill / High-Level Sensor. Model:Tank Overfill / High-Level Sensor. Model: Other (specify equipment type and model in Section E on Page 2).Other (specify equipment type and model in Section E on Page 2). Tank ID:Tank ID: In-Tank Gauging Probe. Model:In-Tank Gauging Probe. Model: Annular Space or Vault Sensor. Model:Annular Space or Vault Sensor. Model: Piping Sump / Trench Sensor(s). Model:Piping Sump / Trench Sensor(s). Model: Fill Sump Sensor(s). Model:Fill Sump Sensor(s). Model: Mechanical Line Leak Detector. Model:Mechanical Line Leak Detector. Model: Electronic Line Leak Detector. Model:Electronic Line Leak Detector. Model: Tank Overfill / High-Level Sensor. Model:Tank Overfill / High-Level Sensor. Model: Other (specify equipment type and model in Section E on Page 2).Other (specify equipment type and model in Section E on Page 2). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s). Model:Dispenser Containment Sensor(s). Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s). Model:Dispenser Containment Sensor(s). Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s). Model:Dispenser Containment Sensor(s). Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers’ guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report;(check all that apply):System set-up Alarm history report Technician Name (print): Signature: Certification No.: License. No.:804904 Testing Company Name:Confidence UST Services, Inc.Phone No.:(800)339-9930 Site Address: Date of Testing/Servicing: Page 1 of 3 #7773 Fastrip #31 3501 Mt. Vernon Avenue Bakersfield 93306 Omero Garcia (661) 393-7000 Veeder-Root TLS-350 08/02/2017 12,000 gal. Regular 847390-107 794390-420 794380-208 794380-208 FX1V 847390-107 12,000 gal. Super 847390-107 794390-420 794380-208 794380-208 FX1V 847390-107 12,000 gal. Diesel 847390-107 794390-420 794380-208 794380-208 FX1DV 847390-107 1-2 794380-208 3-4 794380-208 5-6 794380-208 794380-208 7-8 Transition Sump 794380-208 Aaron Perrigo B47853 3501 Mt. Vernon Avenue Bakersfield, CA 93306 08/02/2017 794380-208 794380-208 794380-208 Monitoring System Certification D. Results of Testing/Servicing Software Version Installed: Complete the following checklist: Yes No* Is the audible alarm operational? Yes No* Is the visual alarm operational? Yes No* Were all sensors visually inspected, functionally tested, and confirmed operational? Yes No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* N/A If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) operational? Yes No* N/A For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) Sump/Trench Sensors; Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection? Yes; No. Yes No* N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? % Yes*No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes*No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) Product; Water. If yes, describe causes in Section E, below. Yes No* Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable Yes No* Is all monitoring equipment operational per manufacturer’s specifications? * In Section E below, describe how and when these deficiencies were or will be corrected. E. Comments: Page 2 of 3 331.01 90 Monitoring System Certification F. In-Tank Gauging / SIR Equipment: Check this box if tank gauging is used only for inventory control. Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: Yes No* Has all input wiring been inspected for proper entry and termination, including testing for ground faults? Yes No* Were all tank gauging probes visually inspected for damage and residue buildup? Yes No* Was accuracy of system product level readings tested? Yes No* Was accuracy of system water level readings tested? Yes No* Were all probes reinstalled properly? Yes No* Were all items on the equipment manufacturer’s maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD):Check this box if LLDs are not installed. Complete the following checklist: Yes No* N/A For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? (Check all that apply)Simulated leak rate: 3 g.p.h.; 0.1 g.p.h ; 0.2 g.p.h. Yes No* Were all LLDs confirmed operational and accurate within regulatory requirements? Yes No* Was the testing apparatus properly calibrated? Yes No* N/A For mechanical LLDs, does the LLD restrict product flow if it detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? Yes No* N/A For electronic LLDs, have all accessible wiring connections been visually inspected? Yes No* Were all items on the equipment manufacturer’s maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. H. Comments: Page 3 of 3 Leak Detector Test Results Sheet Customer Address: Work Order: Site Address: Test Date: Site Contact: Phone: Technician: Phone: 800-339-9930 ICC No.: Product Type LLD Type Model Serial No. Check Valve Holding Pressure Bleed Off ML. Leak Rate Tested: Pass/Fail 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi Technician Name: Technician No.: Signature: Date: Jamieson Hill P.O. Box 82515 Bakersfield, CA 93380-2515 39609 08/02/2017 8485827-UT Regular Mechanical FX1V Aaron Perrigo (661) 393-7000Omero Garcia Bakersfield, CA 93306 3501 Mt. Vernon Avenue #7773/Fastrip #31 12 psi 60 ml Pass FX1VMechanicalPremium 12 psi 35 ml Pass FX1DVMechanicalDiesel 9 psi 80 ml Pass Aaron Perrigo 8485827-UT 08/02/2017 Jaco 7773 Setup Responses Received: 200 FASTRIP 773 3501 MT VERNON BAKERSFIELD CA AUG 2, 2017 9:10 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 5975 55.09 0.0 87.8 6087 2 DIESEL 2744 30.91 0.0 88.0 9318 3 PREMIUM 7223 64.15 1.0 92.1 4839 I90500 AUG 2, 2017 9:10 AM SOFTWARE REVISION LEVEL VERSION 331.01 SOFTWARE# 346331-100-B CREATED - 11.03.22.16.28 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 AUG 2, 2017 9:10 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 AUG 2, 2017 9:10 AM SHIFT TIME 1 : DISABLED I50202 AUG 2, 2017 9:10 AM SHIFT TIME 2 : DISABLED I50203 AUG 2, 2017 9:10 AM SHIFT TIME 3 : DISABLED I50204 AUG 2, 2017 9:10 AM SHIFT TIME 4 : DISABLED I54600 AUG 2, 2017 9:10 AM TANK PER TST NEEDED WRN: DISABLED I54900 AUG 2, 2017 9:10 AM TANK ANN TST NEEDED WRN: DISABLED I55300 AUG 2, 2017 9:10 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 AUG 2, 2017 9:10 AM LINE PER TST NEEDED WRN: DISABLED I55900 AUG 2, 2017 9:10 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 AUG 2, 2017 9:10 AM PRINT TC VOLUMES ENABLED I50E00 AUG 2, 2017 9:10 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 AUG 2, 2017 9:10 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 AUG 2, 2017 9:10 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 AUG 2, 2017 9:10 AM DAYLIGHT SAVING TIME DISABLED I51B00 AUG 2, 2017 9:10 AM I51600 AUG 2, 2017 9:10 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 AUG 2, 2017 9:10 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 AUG 2, 2017 9:10 AM TANK CHART SECURITY DISABLED I5BD00 AUG 2, 2017 9:10 AM CUSTOM ALARM LABELS DISABLED I56000 AUG 2, 2017 9:10 AM MASS/DENSITY DISABLED I88101 AUG 2, 2017 9:10 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 AUG 2, 2017 9:10 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 AUG 2, 2017 9:10 AM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88104 AUG 2, 2017 9:10 AM I88105 AUG 2, 2017 9:10 AM I88106 AUG 2, 2017 9:10 AM I52000 AUG 2, 2017 9:10 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE ??? 2, 2017 DISABLED 2 ON DATE ??? 2, 2017 DISABLED 3 ON DATE ??? 2, 2017 DISABLED 4 ON DATE ??? 2, 2017 DISABLED 5 ON DATE ??? 2, 2017 DISABLED 6 ON DATE ??? 2, 2017 DISABLED 7 ON DATE ??? 2, 2017 DISABLED 8 ON DATE ??? 2, 2017 DISABLED I60100 AUG 2, 2017 9:10 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 DIESEL ON 3 PREMIUM ON 4 OFF I60200 AUG 2, 2017 9:10 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 DIESEL 3 PREMIUM 4 I60300 AUG 2, 2017 9:10 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 DIESEL 2 3 PREMIUM 3 4 4 I60900 AUG 2, 2017 9:10 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 DIESEL 0.000450 3 PREMIUM 0.000700 4 0.000000 I60700 AUG 2, 2017 9:10 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 111.00 2 DIESEL 111.00 3 PREMIUM 111.00 4 0.00 I60A00 AUG 2, 2017 9:10 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 1 PT 12062 2 DIESEL 1 PT 12062 3 PREMIUM 1 PT 12062 4 1 PT 0 I60400 AUG 2, 2017 9:10 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 12062 2 DIESEL 12062 3 PREMIUM 12062 4 0 I60500 AUG 2, 2017 9:10 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12062 0 0 0 2 DIESEL 12062 0 0 0 3 PREMIUM 12062 0 0 0 4 0 0 0 0 I60600 AUG 2, 2017 9:10 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 DIESEL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PREMIUM 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 AUG 2, 2017 9:10 AM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 DIESEL NO 3 PREMIUM NO 4 NO I62F00 AUG 2, 2017 9:10 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 4.0 IN. 2 DIESEL 4.0 IN. 3 PREMIUM 4.0 IN. I62700 AUG 2, 2017 9:10 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 DIESEL 2.0 3 PREMIUM 2.0 I64200 AUG 2, 2017 9:10 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNLEADED LOW 2 DIESEL LOW 3 PREMIUM LOW I62400 AUG 2, 2017 9:10 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 DIESEL 3.0 3 PREMIUM 3.0 I62800 AUG 2, 2017 9:10 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 12062 2 DIESEL 12062 3 PREMIUM 12062 4 0 I62300 AUG 2, 2017 9:10 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 10855 2 DIESEL 10855 3 PREMIUM 10855 4 0 I62200 AUG 2, 2017 9:10 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 11459 2 DIESEL 11459 3 PREMIUM 11459 4 0 I62900 AUG 2, 2017 9:10 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1809 2 DIESEL 1809 3 PREMIUM 1809 4 0 I62100 AUG 2, 2017 9:10 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 500 2 DIESEL 500 3 PREMIUM 500 4 0 I62600 AUG 2, 2017 9:10 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 DIESEL 99 3 PREMIUM 99 4 99 I62500 AUG 2, 2017 9:10 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 DIESEL 99 3 PREMIUM 99 4 99 I60800 AUG 2, 2017 9:10 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 DIESEL 0.00 3 PREMIUM 0.00 4 0.00 I60B00 AUG 2, 2017 9:10 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 AUG 2, 2017 9:10 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 DIESEL 0.00 3 PREMIUM 0.00 4 0.00 I61200 AUG 2, 2017 9:10 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED NONE NONE 2 DIESEL NONE NONE 3 PREMIUM NONE NONE 4 NONE NONE I63600 AUG 2, 2017 9:10 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 DIESEL 120 3 PREMIUM 120 4 0 I62A00 AUG 2, 2017 9:10 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 DIESEL 120 3 PREMIUM 120 4 0 I62C00 AUG 2, 2017 9:10 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 DIESEL STANDARD 3 PREMIUM STANDARD 4 STANDARD I62D00 AUG 2, 2017 9:10 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 AUG 2, 2017 9:10 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 DIESEL OFF OFF 3 PREMIUM OFF OFF 4 OFF OFF I63000 AUG 2, 2017 9:10 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 DIESEL OFF 3 PREMIUM OFF 4 OFF I63200 AUG 2, 2017 9:10 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 DIESEL OFF 3 PREMIUM OFF 4 OFF I61000 AUG 2, 2017 9:10 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 1 2 DIESEL 1 3 PREMIUM 1 4 1 I63A00 AUG 2, 2017 9:10 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 DIESEL 10.00% 3 PREMIUM 10.00% 4 10.00% I61100 AUG 2, 2017 9:10 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK MAR 22, 2011 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 AUG 2, 2017 9:10 AM CSLD PROBABLITY OF DETECTION I61400 AUG 2, 2017 9:10 AM CSLD CLIMATE FACTOR I61600 AUG 2, 2017 9:10 AM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 DIESEL IMMEDIATE 3 PREMIUM IMMEDIATE 4 IMMEDIATE I61A00 AUG 2, 2017 9:10 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED DISABLED 2 DIESEL DISABLED 3 PREMIUM DISABLED 4 DISABLED I61B00 AUG 2, 2017 9:10 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 AUG 2, 2017 9:10 AM CSLD REPORT ONLY I62B00 AUG 2, 2017 9:10 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED ??? 0, 0 2 DIESEL ??? 0, 0 3 PREMIUM ??? 0, 0 4 ??? 0, 0 I63300 AUG 2, 2017 9:10 AM LEAK TEST REPORT FORMAT: NORMAL I63400 AUG 2, 2017 9:10 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 DIESEL 0 3 PREMIUM 0 4 0 I63500 AUG 2, 2017 9:10 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 DIESEL 1 3 PREMIUM 1 4 1 I63900 AUG 2, 2017 9:10 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED END FACTOR: NONE 2 DIESEL END FACTOR: NONE 3 PREMIUM END FACTOR: NONE 4 END FACTOR: NONE I78000 AUG 2, 2017 9:10 AM I77700 AUG 2, 2017 9:10 AM I77800 AUG 2, 2017 9:10 AM I78C00 AUG 2, 2017 9:10 AM I78300 AUG 2, 2017 9:10 AM I78F00 AUG 2, 2017 9:10 AM I78700 AUG 2, 2017 9:10 AM I70200 AUG 2, 2017 9:10 AM LIQUID LABEL DEVICE LABEL 1 UNL ANN 2 DSL ANN 3 PNL ANM 4 UNL STP 5 DSL STP 6 PNL STP 7 8 9 DISP 1-2 10 DISP 3-4 11 DISP 5-6 12 DISP 7-8 13 TRANS SUNP 14 15 16 I70300 AUG 2, 2017 9:10 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL ANN TRI-STATE (SINGLE FLOAT) 2 DSL ANN TRI-STATE (SINGLE FLOAT) 3 PNL ANM TRI-STATE (SINGLE FLOAT) 4 UNL STP TRI-STATE (SINGLE FLOAT) 5 DSL STP TRI-STATE (SINGLE FLOAT) 6 PNL STP TRI-STATE (SINGLE FLOAT) 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 3-4 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 7-8 TRI-STATE (SINGLE FLOAT) 13 TRANS SUNP TRI-STATE (SINGLE FLOAT) 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 AUG 2, 2017 9:10 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL ANN ANNULAR SPACE 2 DSL ANN ANNULAR SPACE 3 PNL ANM ANNULAR SPACE 4 UNL STP STP SUMP 5 DSL STP STP SUMP 6 PNL STP STP SUMP 7 OTHER SENSORS 8 OTHER SENSORS 9 DISP 1-2 DISPENSER PAN 10 DISP 3-4 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 7-8 DISPENSER PAN 13 TRANS SUNP PIPING SUMP 14 OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 AUG 2, 2017 9:10 AM I74300 AUG 2, 2017 9:10 AM I74400 AUG 2, 2017 9:10 AM I74700 AUG 2, 2017 9:10 AM I74800 AUG 2, 2017 9:10 AM I74900 AUG 2, 2017 9:10 AM I7BC00 AUG 2, 2017 9:10 AM I80200 AUG 2, 2017 9:10 AM I80300 AUG 2, 2017 9:10 AM I80400 AUG 2, 2017 9:10 AM I80700 AUG 2, 2017 9:10 AM RELAY LABEL DEVICE LABEL 1 UNL 2 PNL 3 DSL 4 OVERFILL ALARM I80900 AUG 2, 2017 9:11 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL NORMALLY OPEN 2 PNL NORMALLY OPEN 3 DSL NORMALLY CLOSED 4 OVERFILL ALARM NORMALLY OPEN I80B00 AUG 2, 2017 9:11 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 2 PNL 3 3 DSL 2 4 OVERFILL ALARM NONE I80A00 AUG 2, 2017 9:11 AM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL PUMP CONTROL OUTPUT 2 PNL PUMP CONTROL OUTPUT 3 DSL STANDARD 4 OVERFILL ALARM STANDARD I80C00 AUG 2, 2017 9:11 AM I80800 AUG 2, 2017 9:11 AM RELAY SETUP REPORT R 1:UNL TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 4:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 4:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 4:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:PNL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 6:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 6:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 6:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DSL TYPE: STANDARD NORMALLY CLOSED TANK #: 2 LIQUID SENSOR ALMS L 5:FUEL ALARM L10:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 5:SENSOR OUT ALARM L10:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 5:SHORT ALARM L10:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM I79000 AUG 2, 2017 9:11 AM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 AUG 2, 2017 9:11 AM I72300 AUG 2, 2017 9:11 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 PS 1-2 VAPOR PRESSURE 02 FM 1-2 AIR FLOW METER 03 FM 3-4 AIR FLOW METER 04 FM 5-6 AIR FLOW METER 05 FM 7-8 AIR FLOW METER 06 UNKNOWN 07 UNKNOWN 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 AUG 2, 2017 9:11 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 AUG 2, 2017 9:11 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 AUG 2, 2017 9:11 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA VAPOR PROCESSOR TYPE NONE IV4700 AUG 2, 2017 9:11 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 AUG 2, 2017 9:11 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA ACCEPT HIGH ORVR: NO IV4A00 AUG 2, 2017 9:11 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 01 01 01 BLEND3 02 02 02 01 BLEND3 03 03 03 02 BLEND3 04 04 04 02 BLEND3 05 05 05 03 BLEND3 06 06 06 03 BLEND3 07 07 07 04 BLEND3 08 08 08 04 BLEND3 IV4B00 AUG 2, 2017 9:11 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 AUG 2, 2017 9:11 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 AUG 2, 2017 9:11 AM ISD VERSION: 01.04 Jaco 7773 Alarm History Responses Received: I10200 AUG 2, 2017 9:12 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 511865 507444 2 INTERSTITIAL BD 202542 201652 3 4 PROBE / G.T. 162119 161600 4 INTERSTITIAL BD 201727 201242 5 UNUSED 9875362 9631792 6 UNUSED 9851759 9623448 7 UNUSED 9841100 9623142 8 UNUSED 9837166 9625042 9 STP SENSE BOARD 33186 33169 10 RELAY BOARD 15057 15036 11 UNUSED 9842904 9629625 12 UNUSED 9835121 9625147 13 UNUSED 9831462 9622416 14 UNUSED 9830933 9622984 15 UNUSED 9823108 9622897 16 UNUSED 9829030 9622001 COMM 1 ELEC DISP INT. 101235 101188 COMM 2 RS232 SERIAL BD 14929 14904 COMM 3 RS232 SERIAL BD 14972 14970 COMM 4 UNUSED 9844194 9625234 COMM 5 UNUSED 9827613 9623705 COMM 6 UNUSED 9827507 9622045 I90200 AUG 2, 2017 9:12 AM SOFTWARE REVISION LEVEL VERSION 331.01 SOFTWARE# 346331-100-B CREATED - 11.03.22.16.28 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 AUG 2, 2017 9:12 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK UNLEADED OVERFILL ALARM CLEAR 7-29-17 10:24PM T 1 TANK UNLEADED OVERFILL ALARM ALARM 7-29-17 10:21PM L 3 ANNULAR PNL ANM FUEL ALARM CLEAR 7-25-17 11:28AM L 3 ANNULAR PNL ANM SENSOR OUT ALARM CLEAR 7-25-17 10:51AM L 3 ANNULAR PNL ANM FUEL ALARM ALARM 7-25-17 10:51AM L 2 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 7-25-17 10:51AM L 6 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 7-25-17 10:51AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 7-25-17 10:51AM L 4 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 7-25-17 10:51AM L 5 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 7-25-17 10:51AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 7-25-17 10:51AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 7-25-17 10:51AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 7-25-17 10:51AM L13 PIPE TRANS SUNP SENSOR OUT ALARM CLEAR 7-25-17 10:51AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 7-25-17 10:51AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 7-25-17 10:50AM L 6 STP SUMP PNL STP SENSOR OUT ALARM ALARM 7-25-17 10:50AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 7-25-17 10:50AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 7-25-17 10:50AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 7-25-17 10:50AM L 4 STP SUMP UNL STP SENSOR OUT ALARM ALARM 7-25-17 10:50AM L 3 ANNULAR PNL ANM SENSOR OUT ALARM ALARM 7-25-17 10:50AM L 3 ANNULAR PNL ANM FUEL ALARM CLEAR 7-25-17 10:50AM L 2 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 7-25-17 10:50AM L13 PIPE TRANS SUNP SENSOR OUT ALARM ALARM 7-25-17 10:50AM L 5 STP SUMP DSL STP SENSOR OUT ALARM ALARM 7-25-17 10:50AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 7-25-17 10:50AM T 3 TANK PREMIUM PROBE OUT CLEAR 7-25-17 10:09AM T 3 TANK PREMIUM PROBE OUT ALARM 7-25-17 10:09AM T 2 TANK DIESEL PROBE OUT CLEAR 7-25-17 10:08AM T 2 TANK DIESEL PROBE OUT ALARM 7-25-17 10:08AM T 1 TANK UNLEADED PROBE OUT CLEAR 7-25-17 10:07AM T 1 TANK UNLEADED OVERFILL ALARM CLEAR 7-25-17 10:06AM T 1 TANK UNLEADED PROBE OUT ALARM 7-25-17 10:06AM T 1 TANK UNLEADED OVERFILL ALARM ALARM 7-25-17 10:05AM T 2 TANK DIESEL OVERFILL ALARM CLEAR 7-25-17 10:04AM T 2 TANK DIESEL OVERFILL ALARM ALARM 7-25-17 10:03AM T 2 TANK DIESEL OVERFILL ALARM CLEAR 7-25-17 10:02AM T 3 TANK PREMIUM OVERFILL ALARM CLEAR 7-25-17 10:00AM T 2 TANK DIESEL OVERFILL ALARM ALARM 7-25-17 10:00AM T 3 TANK PREMIUM OVERFILL ALARM ALARM 7-25-17 9:59AM L 2 ANNULAR DSL ANN FUEL ALARM CLEAR 7-25-17 9:58AM L13 PIPE TRANS SUNP FUEL ALARM CLEAR 7-25-17 9:54AM L13 PIPE TRANS SUNP FUEL ALARM ALARM 7-25-17 9:53AM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 7-25-17 9:52AM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 7-25-17 9:52AM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 7-25-17 9:52AM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 7-25-17 9:52AM L10 DISP PAN DISP 3-4 FUEL ALARM CLEAR 7-25-17 9:51AM L10 DISP PAN DISP 3-4 FUEL ALARM ALARM 7-25-17 9:51AM I11200 AUG 2, 2017 9:12 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK DIESEL DELIVERY NEEDED CLEAR 7-29-17 10:00PM T 2 TANK DIESEL DELIVERY NEEDED ALARM 7-29-17 9:36AM T 1 TANK UNLEADED HIGH PRODUCT ALARM CLEAR 7-25-17 10:06AM T 1 TANK UNLEADED HIGH PRODUCT ALARM ALARM 7-25-17 10:06AM T 2 TANK DIESEL HIGH PRODUCT ALARM CLEAR 7-25-17 10:03AM T 2 TANK DIESEL HIGH PRODUCT ALARM ALARM 7-25-17 10:03AM T 2 TANK DIESEL HIGH PRODUCT ALARM CLEAR 7-25-17 10:01AM T 2 TANK DIESEL HIGH PRODUCT ALARM ALARM 7-25-17 10:00AM T 3 TANK PREMIUM HIGH PRODUCT ALARM CLEAR 7-25-17 9:59AM T 3 TANK PREMIUM HIGH PRODUCT ALARM ALARM 7-25-17 9:59AM SYSTEM PRINTER ERROR CLEAR 7-25-17 9:24AM SYSTEM PRINTER ERROR ALARM 7-25-17 9:24AM SYSTEM PRINTER ERROR CLEAR 7-25-17 9:23AM SYSTEM PAPER OUT CLEAR 7-25-17 9:23AM SYSTEM PAPER OUT ALARM 7-25-17 9:23AM SYSTEM PAPER OUT CLEAR 7-25-17 9:23AM SYSTEM PRINTER ERROR ALARM 7-25-17 9:19AM SYSTEM PAPER OUT ALARM 7-25-17 9:19AM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 7-25-17 9:14AM T 2 TANK DIESEL DELIVERY NEEDED ALARM 7-25-17 9:13AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-24-17 7:02PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-24-17 6:30PM SYSTEM PRINTER ERROR CLEAR 7-04-17 2:51AM SYSTEM PRINTER ERROR ALARM 7-04-17 2:51AM SYSTEM PAPER OUT CLEAR 7-04-17 2:51AM SYSTEM PRINTER ERROR CLEAR 7-04-17 2:49AM SYSTEM PRINTER ERROR ALARM 7-04-17 2:49AM SYSTEM PRINTER ERROR CLEAR 7-04-17 2:49AM SYSTEM PRINTER ERROR ALARM 7-04-17 2:48AM SYSTEM PAPER OUT ALARM 7-04-17 2:47AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-27-17 2:50AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-26-17 11:11PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-22-17 7:18PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-22-17 6:45PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-22-17 12:13AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-21-17 10:41PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-20-17 6:12AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-19-17 9:45PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-17-17 4:33AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-16-17 10:08PM SYSTEM PAPER OUT CLEAR 6-16-17 1:14PM SYSTEM PAPER OUT ALARM 6-16-17 1:13PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-15-17 1:23PM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 6-15-17 1:20PM T 1 TANK UNLEADED INVALID FUEL LEVEL ALARM 6-15-17 12:56PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-15-17 10:23AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-12-17 6:20AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-12-17 5:24AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-10-17 3:19AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-09-17 11:55PM I20600 AUG 2, 2017 9:12 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA TANK ALARM HISTORY TANK 1 UNLEADED HIGH WATER ALARM JUL 27, 2016 10:28 AM OVERFILL ALARM JUL 29, 2017 10:21 PM JUL 25, 2017 10:05 AM JUL 18, 2017 2:50 AM LOW PRODUCT ALARM JUN 15, 2017 12:48 PM JUN 6, 2017 6:32 PM JUN 5, 2017 5:46 PM SUDDEN LOSS ALARM JUL 25, 2017 9:15 AM AUG 31, 2016 5:10 PM AUG 2, 2016 9:06 AM HIGH PRODUCT ALARM JUL 25, 2017 10:06 AM APR 14, 2017 6:21 AM AUG 2, 2016 9:20 AM INVALID FUEL LEVEL JUN 15, 2017 12:56 PM JUN 6, 2017 6:37 PM JUN 5, 2017 5:52 PM PROBE OUT JUL 25, 2017 10:06 AM JUL 25, 2017 9:15 AM AUG 31, 2016 5:20 PM HIGH WATER WARNING JUL 27, 2016 10:28 AM DELIVERY NEEDED JUL 24, 2017 6:30 PM JUN 26, 2017 11:11 PM JUN 22, 2017 6:45 PM LOW TEMP WARNING AUG 31, 2016 5:24 PM AUG 2, 2016 9:22 AM JUL 28, 2015 11:29 AM TANK 2 DIESEL OVERFILL ALARM JUL 25, 2017 10:03 AM JUL 25, 2017 10:00 AM AUG 2, 2016 9:23 AM HIGH PRODUCT ALARM JUL 25, 2017 10:03 AM JUL 25, 2017 10:00 AM JUL 27, 2016 10:26 AM INVALID FUEL LEVEL JUL 27, 2016 10:37 AM JUL 21, 2014 12:36 PM PROBE OUT JUL 25, 2017 10:08 AM JUL 25, 2017 9:13 AM AUG 2, 2016 9:23 AM HIGH WATER WARNING JUL 27, 2016 10:29 AM DELIVERY NEEDED JUL 29, 2017 9:36 AM JUL 25, 2017 9:13 AM MAY 28, 2017 5:56 PM MAX PRODUCT ALARM AUG 6, 2013 1:47 PM LOW TEMP WARNING AUG 4, 2015 10:16 AM AUG 4, 2014 9:16 AM AUG 6, 2013 1:49 PM TANK 3 PREMIUM OVERFILL ALARM JUL 25, 2017 9:59 AM AUG 2, 2016 9:25 AM JUL 28, 2015 11:23 AM LOW PRODUCT ALARM JUL 27, 2016 9:40 AM SUDDEN LOSS ALARM JUL 25, 2017 9:07 AM MAR 23, 2017 10:38 AM AUG 2, 2016 9:03 AM HIGH PRODUCT ALARM JUL 25, 2017 9:59 AM AUG 2, 2016 9:25 AM JUL 27, 2016 10:26 AM INVALID FUEL LEVEL JUL 27, 2016 9:40 AM AUG 4, 2014 10:39 AM AUG 6, 2013 1:01 PM PROBE OUT JUL 25, 2017 10:09 AM JUL 25, 2017 9:07 AM MAR 23, 2017 10:39 AM HIGH WATER WARNING AUG 7, 2012 2:20 PM DELIVERY NEEDED MAR 23, 2017 11:26 AM MAR 23, 2017 10:38 AM AUG 2, 2016 9:04 AM MAX PRODUCT ALARM AUG 11, 2011 1:19 PM LOW TEMP WARNING AUG 2, 2016 9:26 AM JUL 27, 2016 11:22 AM AUG 4, 2015 10:18 AM I38200 AUG 2, 2017 9:12 AM I30200 AUG 2, 2017 9:12 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL ANN JUL 25, 2017 10:50 AM SENSOR OUT ALARM JUL 25, 2017 9:48 AM FUEL ALARM JAN 17, 2017 10:55 AM FUEL ALARM 2 DSL ANN JUL 25, 2017 10:50 AM SENSOR OUT ALARM JUL 25, 2017 9:49 AM FUEL ALARM JUL 25, 2017 9:48 AM FUEL ALARM 3 PNL ANM JUL 25, 2017 10:51 AM FUEL ALARM JUL 25, 2017 10:50 AM SENSOR OUT ALARM JUL 25, 2017 9:50 AM FUEL ALARM 4 UNL STP JUL 25, 2017 10:50 AM SENSOR OUT ALARM JUL 25, 2017 9:45 AM FUEL ALARM AUG 2, 2016 9:55 AM SENSOR OUT ALARM 5 DSL STP JUL 25, 2017 10:50 AM SENSOR OUT ALARM JUL 25, 2017 9:45 AM FUEL ALARM JUL 10, 2017 6:48 AM FUEL ALARM 6 PNL STP JUL 25, 2017 10:50 AM SENSOR OUT ALARM JUL 25, 2017 9:44 AM FUEL ALARM JAN 23, 2017 4:42 PM FUEL ALARM 9 DISP 1-2 JUL 25, 2017 10:50 AM SENSOR OUT ALARM JUL 25, 2017 9:52 AM FUEL ALARM AUG 2, 2016 9:55 AM SENSOR OUT ALARM 10 DISP 3-4 JUL 25, 2017 10:50 AM SENSOR OUT ALARM JUL 25, 2017 9:51 AM FUEL ALARM AUG 2, 2016 9:55 AM SENSOR OUT ALARM 11 DISP 5-6 JUL 25, 2017 10:50 AM SENSOR OUT ALARM JUL 25, 2017 9:52 AM FUEL ALARM AUG 2, 2016 9:55 AM SENSOR OUT ALARM 12 DISP 7-8 JUL 25, 2017 10:50 AM SENSOR OUT ALARM JUL 25, 2017 9:50 AM FUEL ALARM AUG 2, 2016 9:55 AM SENSOR OUT ALARM 13 TRANS SUNP JUL 25, 2017 10:50 AM SENSOR OUT ALARM JUL 25, 2017 9:53 AM FUEL ALARM AUG 2, 2016 9:55 AM SENSOR OUT ALARM I31600 AUG 2, 2017 9:13 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 1-2 2 FM 1-2 3 FM 3-4 4 FM 5-6 DEC 28, 2015 2:11 PM COMMUNICATION ALARM JUN 3, 2011 11:01 AM COMMUNICATION ALARM 5 FM 7-8 JUN 3, 2011 11:01 AM COMMUNICATION ALARM I40200 AUG 2, 2017 9:13 AM I40300 AUG 2, 2017 9:13 AM I34200 AUG 2, 2017 9:13 AM I34700 AUG 2, 2017 9:13 AM IV0100 AUG 2, 2017 9:13 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.04 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 17-03-20 10:02:37 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 8.58 17-03-04 10:02:37 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.96 17-02-25 10:01:45 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.78 17-02-16 10:02:25 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.06 17-02-09 10:01:49 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.49 17-02-08 10:01:44 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.14 17-02-07 10:01:43 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 10.42 17-02-02 10:02:23 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.89 17-01-26 10:01:54 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.81 17-01-19 10:01:52 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.91 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 16-03-25 12:03:28 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 BLKD 13-08-12 10:01:28 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 13-08-11 10:03:38 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 13-01-20 10:01:52 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 13-01-20 10:01:52 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 17-07-26 10:02:12 READINESS ISD:PP EVR:PP ISD & EVR READY 17-07-25 10:50:13 READINESS ISD:PP EVR:NN EVR READINESS PENDING 17-07-25 10:50:13 ISD STARTUP 17-07-25 10:50:03 ISD SHUTDOWN 17-03-23 14:17:00 TIME CHANGE DETECTED AT: 17-03-23 13:18:14 17-03-21 08:16:05 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED 17-03-04 12:55:35 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 17-02-25 10:19:46 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 17-02-16 10:29:21 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 17-02-02 10:05:50 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED Jaco 7773 Alarm History After Responses Received: I10200 AUG 2, 2017 10:58 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 511865 507468 2 INTERSTITIAL BD 202542 201952 3 4 PROBE / G.T. 162119 161702 4 INTERSTITIAL BD 201727 201266 5 UNUSED 9875362 9607655 6 UNUSED 9851759 9601604 7 UNUSED 9841100 9600355 8 UNUSED 9837166 9600245 9 STP SENSE BOARD 33186 33191 10 RELAY BOARD 15057 15080 11 UNUSED 9842904 9602539 12 UNUSED 9835121 9604665 13 UNUSED 9831462 9601048 14 UNUSED 9830933 9591248 15 UNUSED 9823108 9598088 16 UNUSED 9829030 9601771 COMM 1 ELEC DISP INT. 101235 101307 COMM 2 RS232 SERIAL BD 14929 14926 COMM 3 RS232 SERIAL BD 14972 14992 COMM 4 UNUSED 9844194 9606200 COMM 5 UNUSED 9827613 9601399 COMM 6 UNUSED 9827507 9601399 I90200 AUG 2, 2017 10:58 AM SOFTWARE REVISION LEVEL VERSION 331.01 SOFTWARE# 346331-100-B CREATED - 11.03.22.16.28 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 AUG 2, 2017 10:58 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 6 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 8-02-17 10:57AM L 4 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 8-02-17 10:57AM L 3 ANNULAR PNL ANM SENSOR OUT ALARM CLEAR 8-02-17 10:57AM L 2 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 8-02-17 10:57AM L 5 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 8-02-17 10:57AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 8-02-17 10:57AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 8-02-17 10:56AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 8-02-17 10:56AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 8-02-17 10:56AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 8-02-17 10:56AM L13 PIPE TRANS SUNP SENSOR OUT ALARM CLEAR 8-02-17 10:56AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 8-02-17 10:56AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 8-02-17 10:56AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 8-02-17 10:56AM L13 PIPE TRANS SUNP SENSOR OUT ALARM ALARM 8-02-17 10:56AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 8-02-17 10:56AM L 4 STP SUMP UNL STP SENSOR OUT ALARM ALARM 8-02-17 10:56AM L 3 ANNULAR PNL ANM SENSOR OUT ALARM ALARM 8-02-17 10:56AM L 2 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 8-02-17 10:56AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 8-02-17 10:56AM L 6 STP SUMP PNL STP SENSOR OUT ALARM ALARM 8-02-17 10:56AM L 5 STP SUMP DSL STP SENSOR OUT ALARM ALARM 8-02-17 10:56AM T 1 TANK UNLEADED PROBE OUT CLEAR 8-02-17 10:31AM T 1 TANK UNLEADED PROBE OUT ALARM 8-02-17 10:31AM T 2 TANK DIESEL PROBE OUT CLEAR 8-02-17 10:30AM T 2 TANK DIESEL PROBE OUT ALARM 8-02-17 10:30AM T 3 TANK PREMIUM PROBE OUT CLEAR 8-02-17 10:29AM T 3 TANK PREMIUM PROBE OUT ALARM 8-02-17 10:29AM T 3 TANK PREMIUM SUDDEN LOSS ALARM CLEAR 8-02-17 10:14AM T 3 TANK PREMIUM SUDDEN LOSS ALARM ALARM 8-02-17 9:52AM L 3 ANNULAR PNL ANM FUEL ALARM CLEAR 8-02-17 9:50AM L 3 ANNULAR PNL ANM FUEL ALARM ALARM 8-02-17 9:50AM L 1 ANNULAR UNL ANN FUEL ALARM CLEAR 8-02-17 9:44AM L 1 ANNULAR UNL ANN FUEL ALARM ALARM 8-02-17 9:41AM L13 PIPE TRANS SUNP FUEL ALARM CLEAR 8-02-17 9:40AM L13 PIPE TRANS SUNP FUEL ALARM ALARM 8-02-17 9:40AM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 8-02-17 9:39AM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 8-02-17 9:39AM L10 DISP PAN DISP 3-4 FUEL ALARM CLEAR 8-02-17 9:38AM L10 DISP PAN DISP 3-4 FUEL ALARM ALARM 8-02-17 9:38AM L12 DISP PAN DISP 7-8 FUEL ALARM CLEAR 8-02-17 9:37AM L12 DISP PAN DISP 7-8 FUEL ALARM ALARM 8-02-17 9:37AM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 8-02-17 9:37AM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 8-02-17 9:37AM L 4 STP SUMP UNL STP FUEL ALARM CLEAR 8-02-17 9:36AM L 4 STP SUMP UNL STP FUEL ALARM ALARM 8-02-17 9:36AM L 6 STP SUMP PNL STP FUEL ALARM CLEAR 8-02-17 9:35AM L 6 STP SUMP PNL STP FUEL ALARM ALARM 8-02-17 9:35AM L 5 STP SUMP DSL STP FUEL ALARM CLEAR 8-02-17 9:35AM L 5 STP SUMP DSL STP FUEL ALARM ALARM 8-02-17 9:35AM I11200 AUG 2, 2017 10:58 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK UNLEADED LOW TEMP WARNING CLEAR 8-02-17 10:31AM T 1 TANK UNLEADED LOW TEMP WARNING ALARM 8-02-17 10:31AM T 1 TANK UNLEADED HIGH PRODUCT ALARM CLEAR 8-02-17 9:53AM T 1 TANK UNLEADED HIGH PRODUCT ALARM ALARM 8-02-17 9:53AM T 2 TANK DIESEL HIGH PRODUCT ALARM CLEAR 8-02-17 9:52AM T 2 TANK DIESEL HIGH PRODUCT ALARM ALARM 8-02-17 9:52AM T 3 TANK PREMIUM HIGH PRODUCT ALARM CLEAR 8-02-17 9:51AM T 3 TANK PREMIUM HIGH PRODUCT ALARM ALARM 8-02-17 9:51AM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 8-02-17 9:32AM T 2 TANK DIESEL DELIVERY NEEDED ALARM 8-02-17 9:31AM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 7-29-17 10:00PM T 2 TANK DIESEL DELIVERY NEEDED ALARM 7-29-17 9:36AM T 1 TANK UNLEADED HIGH PRODUCT ALARM CLEAR 7-25-17 10:06AM T 1 TANK UNLEADED HIGH PRODUCT ALARM ALARM 7-25-17 10:06AM T 2 TANK DIESEL HIGH PRODUCT ALARM CLEAR 7-25-17 10:03AM T 2 TANK DIESEL HIGH PRODUCT ALARM ALARM 7-25-17 10:03AM T 2 TANK DIESEL HIGH PRODUCT ALARM CLEAR 7-25-17 10:01AM T 2 TANK DIESEL HIGH PRODUCT ALARM ALARM 7-25-17 10:00AM T 3 TANK PREMIUM HIGH PRODUCT ALARM CLEAR 7-25-17 9:59AM T 3 TANK PREMIUM HIGH PRODUCT ALARM ALARM 7-25-17 9:59AM SYSTEM PRINTER ERROR CLEAR 7-25-17 9:24AM SYSTEM PRINTER ERROR ALARM 7-25-17 9:24AM SYSTEM PRINTER ERROR CLEAR 7-25-17 9:23AM SYSTEM PAPER OUT CLEAR 7-25-17 9:23AM SYSTEM PAPER OUT ALARM 7-25-17 9:23AM SYSTEM PAPER OUT CLEAR 7-25-17 9:23AM SYSTEM PRINTER ERROR ALARM 7-25-17 9:19AM SYSTEM PAPER OUT ALARM 7-25-17 9:19AM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 7-25-17 9:14AM T 2 TANK DIESEL DELIVERY NEEDED ALARM 7-25-17 9:13AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 7-24-17 7:02PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 7-24-17 6:30PM SYSTEM PRINTER ERROR CLEAR 7-04-17 2:51AM SYSTEM PRINTER ERROR ALARM 7-04-17 2:51AM SYSTEM PAPER OUT CLEAR 7-04-17 2:51AM SYSTEM PRINTER ERROR CLEAR 7-04-17 2:49AM SYSTEM PRINTER ERROR ALARM 7-04-17 2:49AM SYSTEM PRINTER ERROR CLEAR 7-04-17 2:49AM SYSTEM PRINTER ERROR ALARM 7-04-17 2:48AM SYSTEM PAPER OUT ALARM 7-04-17 2:47AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-27-17 2:50AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-26-17 11:11PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-22-17 7:18PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-22-17 6:45PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-22-17 12:13AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-21-17 10:41PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-20-17 6:12AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-19-17 9:45PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-17-17 4:33AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-16-17 10:08PM I20600 AUG 2, 2017 10:58 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA TANK ALARM HISTORY TANK 1 UNLEADED HIGH WATER ALARM JUL 27, 2016 10:28 AM OVERFILL ALARM JUL 29, 2017 10:21 PM JUL 25, 2017 10:05 AM JUL 18, 2017 2:50 AM LOW PRODUCT ALARM JUN 15, 2017 12:48 PM JUN 6, 2017 6:32 PM JUN 5, 2017 5:46 PM SUDDEN LOSS ALARM AUG 2, 2017 9:33 AM JUL 25, 2017 9:15 AM AUG 31, 2016 5:10 PM HIGH PRODUCT ALARM AUG 2, 2017 9:53 AM JUL 25, 2017 10:06 AM APR 14, 2017 6:21 AM INVALID FUEL LEVEL JUN 15, 2017 12:56 PM JUN 6, 2017 6:37 PM JUN 5, 2017 5:52 PM PROBE OUT AUG 2, 2017 10:31 AM AUG 2, 2017 9:33 AM JUL 25, 2017 10:06 AM HIGH WATER WARNING JUL 27, 2016 10:28 AM DELIVERY NEEDED JUL 24, 2017 6:30 PM JUN 26, 2017 11:11 PM JUN 22, 2017 6:45 PM LOW TEMP WARNING AUG 2, 2017 10:31 AM AUG 31, 2016 5:24 PM AUG 2, 2016 9:22 AM TANK 2 DIESEL OVERFILL ALARM JUL 25, 2017 10:03 AM JUL 25, 2017 10:00 AM AUG 2, 2016 9:23 AM HIGH PRODUCT ALARM AUG 2, 2017 9:52 AM JUL 25, 2017 10:03 AM JUL 25, 2017 10:00 AM INVALID FUEL LEVEL JUL 27, 2016 10:37 AM JUL 21, 2014 12:36 PM PROBE OUT AUG 2, 2017 10:30 AM AUG 2, 2017 9:31 AM JUL 25, 2017 10:08 AM HIGH WATER WARNING JUL 27, 2016 10:29 AM DELIVERY NEEDED AUG 2, 2017 9:31 AM JUL 29, 2017 9:36 AM JUL 25, 2017 9:13 AM MAX PRODUCT ALARM AUG 6, 2013 1:47 PM LOW TEMP WARNING AUG 4, 2015 10:16 AM AUG 4, 2014 9:16 AM AUG 6, 2013 1:49 PM TANK 3 PREMIUM OVERFILL ALARM JUL 25, 2017 9:59 AM AUG 2, 2016 9:25 AM JUL 28, 2015 11:23 AM LOW PRODUCT ALARM JUL 27, 2016 9:40 AM SUDDEN LOSS ALARM AUG 2, 2017 9:52 AM AUG 2, 2017 9:32 AM JUL 25, 2017 9:07 AM HIGH PRODUCT ALARM AUG 2, 2017 9:51 AM JUL 25, 2017 9:59 AM AUG 2, 2016 9:25 AM INVALID FUEL LEVEL JUL 27, 2016 9:40 AM AUG 4, 2014 10:39 AM AUG 6, 2013 1:01 PM PROBE OUT AUG 2, 2017 10:29 AM AUG 2, 2017 9:32 AM JUL 25, 2017 10:09 AM HIGH WATER WARNING AUG 7, 2012 2:20 PM DELIVERY NEEDED MAR 23, 2017 11:26 AM MAR 23, 2017 10:38 AM AUG 2, 2016 9:04 AM MAX PRODUCT ALARM AUG 11, 2011 1:19 PM LOW TEMP WARNING AUG 2, 2016 9:26 AM JUL 27, 2016 11:22 AM AUG 4, 2015 10:18 AM I38200 AUG 2, 2017 10:58 AM I30200 AUG 2, 2017 10:58 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL ANN AUG 2, 2017 10:56 AM SENSOR OUT ALARM AUG 2, 2017 9:41 AM FUEL ALARM JUL 25, 2017 10:50 AM SENSOR OUT ALARM 2 DSL ANN AUG 2, 2017 10:56 AM SENSOR OUT ALARM JUL 25, 2017 10:50 AM SENSOR OUT ALARM JUL 25, 2017 9:49 AM FUEL ALARM 3 PNL ANM AUG 2, 2017 10:56 AM SENSOR OUT ALARM AUG 2, 2017 9:50 AM FUEL ALARM JUL 25, 2017 10:51 AM FUEL ALARM 4 UNL STP AUG 2, 2017 10:56 AM SENSOR OUT ALARM AUG 2, 2017 9:36 AM FUEL ALARM JUL 25, 2017 10:50 AM SENSOR OUT ALARM 5 DSL STP AUG 2, 2017 10:56 AM SENSOR OUT ALARM AUG 2, 2017 9:35 AM FUEL ALARM JUL 25, 2017 10:50 AM SENSOR OUT ALARM 6 PNL STP AUG 2, 2017 10:56 AM SENSOR OUT ALARM AUG 2, 2017 9:35 AM FUEL ALARM JUL 25, 2017 10:50 AM SENSOR OUT ALARM 9 DISP 1-2 AUG 2, 2017 10:56 AM SENSOR OUT ALARM AUG 2, 2017 9:39 AM FUEL ALARM JUL 25, 2017 10:50 AM SENSOR OUT ALARM 10 DISP 3-4 AUG 2, 2017 10:56 AM SENSOR OUT ALARM AUG 2, 2017 9:38 AM FUEL ALARM JUL 25, 2017 10:50 AM SENSOR OUT ALARM 11 DISP 5-6 AUG 2, 2017 10:56 AM SENSOR OUT ALARM AUG 2, 2017 9:37 AM FUEL ALARM JUL 25, 2017 10:50 AM SENSOR OUT ALARM 12 DISP 7-8 AUG 2, 2017 10:56 AM SENSOR OUT ALARM AUG 2, 2017 9:37 AM FUEL ALARM JUL 25, 2017 10:50 AM SENSOR OUT ALARM 13 TRANS SUNP AUG 2, 2017 10:56 AM SENSOR OUT ALARM AUG 2, 2017 9:40 AM FUEL ALARM JUL 25, 2017 10:50 AM SENSOR OUT ALARM I31600 AUG 2, 2017 10:58 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 1-2 2 FM 1-2 3 FM 3-4 4 FM 5-6 DEC 28, 2015 2:11 PM COMMUNICATION ALARM JUN 3, 2011 11:01 AM COMMUNICATION ALARM 5 FM 7-8 JUN 3, 2011 11:01 AM COMMUNICATION ALARM I40200 AUG 2, 2017 10:58 AM I40300 AUG 2, 2017 10:58 AM I34200 AUG 2, 2017 10:58 AM I34700 AUG 2, 2017 10:58 AM IV0100 AUG 2, 2017 10:58 AM FASTRIP 773 3501 MT VERNON BAKERSFIELD CA ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.04 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 17-03-20 10:02:37 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 8.58 17-03-04 10:02:37 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.96 17-02-25 10:01:45 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.78 17-02-16 10:02:25 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.06 17-02-09 10:01:49 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.49 17-02-08 10:01:44 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.14 17-02-07 10:01:43 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 10.42 17-02-02 10:02:23 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.89 17-01-26 10:01:54 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.81 17-01-19 10:01:52 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.91 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 16-03-25 12:03:28 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 BLKD 13-08-12 10:01:28 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 13-08-11 10:03:38 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 13-01-20 10:01:52 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 13-01-20 10:01:52 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 17-08-02 10:55:26 READINESS ISD:PP EVR:NN EVR READINESS PENDING 17-08-02 10:55:26 ISD STARTUP 17-08-02 10:55:17 ISD SHUTDOWN 17-07-26 10:02:12 READINESS ISD:PP EVR:PP ISD & EVR READY 17-07-25 10:50:13 READINESS ISD:PP EVR:NN EVR READINESS PENDING 17-07-25 10:50:13 ISD STARTUP 17-07-25 10:50:03 ISD SHUTDOWN 17-03-23 14:17:00 TIME CHANGE DETECTED AT: 17-03-23 13:18:14 17-03-21 08:16:05 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED 17-03-04 12:55:35 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: Date of Testing: Facility Address: Facility Contact: Phone: Date Local Agency Was Notified of Testing : Name of Local Agency Inspector (if present during testing): 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST Services, Inc. Technician Conducting Test: Credentials1:6 CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s): CSLB# 804904 ICC# 3. SPILL BUCKET TESTING INFORMATION Test Method Used:6 Hydrostatic Vacuum Other Test Equipment Used: Lake Test Equipment Resolution: 0.0625” Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1234 Bucket Installation Type: Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test: Test Start Time (TI): Initial Reading (RI): Test End Time (TF): Final Reading (RF): Test Duration (TF – TI): Change in Reading (RF -RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Comments –(include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician’s Signature:________________________________________________ Date: _________ 1 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. #7773 Fastrip #31 08/02/2017 3501 Mt. Vernon Avenue Bakersfield, CA 93306 Omero Garcia (661) 393-7000 07/19/2017 Kris Karns Aaron Perrigo 8485827-UT Regular 12.00" 13.00" 5 min. 9:15 am 9.50" 10:15 am 9.50" 1 hour 0.00" 0.0625" Super 12.00" 13.50" 5 min. 9:15 am 9.50" 10:15 am 9.50" 1 hour 0.00" 1 hour 1 hour Diesel 12.00" 13.00" 5 min. 9:15 am 9.50" 10:15 am 9.50" 1 hour 0.00" 08/02/2017