Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
9855 COMPAGNONI ST (2)
11111111111111111111 40 HOODS ALARMS SPRINKLER SYSTEMS SPRAY BOOTH AST UST Permit No. Permit No. Permit No. Permit No. Permit No. Permit No. /[02�3 File Number: Date Received: �S S Address: 25,56-- Cot, Bakersfield, CA 933 Business Name:41�%C/c��T SYSTEM: BUILDING SQUARE FEET: New Mod. ❑ ❑ Commercial Hood System ❑ ❑ Fire Alarm System ❑ ❑ Fire Sprinkler System ❑ ❑ Spray Finish System ❑ x Aboveground Storage Tank ❑ ❑ Underground Storage Tank minor modification Underground Storage Tank removal Underground Storage Tank ❑ ❑ Other: Comments: Building Sq. Feet: Calculation Bldg. Sq. Ft: 1. 2. 3. 4. INSPECTION LOG Date /Y- A Signature Signature KFS -9477 BAKERSFIELD FIRE DEPARTMENT ABOVEGROUND STORAGE TANKPrevention Services a BPiB< 1 n 2101 H Street "rm r Bakersfield, CA 93301 Phone: 661-326-3979 • Fax: 661-852-2171 Page 1 Of 2 INSTALL Lj REMOVE PERMIT # FACILITY NAME 04? '6A-K695FIE1,7 F1E1,17 AND ii169AT" OF -T --t 6 ADDRESS 01005-5- 10055OPERATOR OPERATORNAME CRP 1bAK6¢5'T;l G L PERMIT TO OPERATE # OWNER NAME NP ez5 ►El.i7 IED AND DIS?ATC.*I # OF TANKS TO BE INSTALLED._ /REMOVED Q TANK # CONTENTS VOLUME MOIi�Rr1 WC.IAINfn F�Q.Efnvl4SZp UWur'-pmeo �'1 12 00o A(A Y' NAME OF COMPANY INSTALLING AND/OR REMOVING TANK VET�Q50� µy i4crvt,1C5 1 N C. MAILING ADDRESS 11053 IN. 1, 5SCnVr4V0 FJLVD. NAME & PHONE # OF CONTACT PERSON MfriT D G 310 • 345 2dlb DATE & TIME TANK IS TO BE INSTALLED/REMOVED UNE 231 2_ ots- SIGNATU OF APP T DATE APPROVED DATE FD2081 (Rev 05/10) NSJ BILLING & PERMIT STATEMENTBAKERSFIELD FIRE DEPARTMENT s � R�rskL Prevention Services PERMIT # ,Rr. 2101 H Street carer s Bakersfield, CA 93301 , Please make checks payable to CITY OF BAKERSFIELD. NO CASH Please. Thank you.ONLY PERMIT TYPE FEE CALCULATION TOTAL • TREASURY ❑ INFORMATIONSITE $280 LOCATION OF PROJECT 9855 Compagnoni Street, Bakersfield, Ca. 93313 PROPERTY OWNER DB Bakersfield, LLC - - STARTING DATE COMPLETION DATE 6-1-2014 10-15-2015 NAME Ken Dye P0. ECT NAME P %U SReLD flf�-D NOV) ?RT FiCZ ADDRESS' 6250 Sky Creek PHONE it 916-520-7623 PROJECT ADDRESSCITY °I$SS C1�r�Q oN 5T 6 Sacramento, Ca. ZIPCODE = 95828 CONTRACTOR INFORMATION CONTRACTOR NAME , FCA LICENSE & TYPE OF LICENSE EXPIRATION DATE - PHONE # - KNN -R StX4 (03fs)6- 30-90(0 310 32.3 3165 CONTRACTOR COMPANY NAME FAX 0 Y 5o DRVta lfvG 310 323 sloofo ADDRESS 1to53 W_ EL SEGwNDO $t,VO, CITYZIP Ilk(WIEN q CODE 67_q gj Please make checks payable to CITY OF BAKERSFIELD. NO CASH Please. Thank you.ONLY PERMIT TYPE FEE CALCULATION TOTAL • TREASURY ❑ Alarm - New & Modification (minimum charge) $280 DUE ACCT NO ❑ - Over. 10,000 sq'ft $0 .028 x sq ft ❑ Sprinkler - New & Modification (minimum charge) $280 ❑ Over 10,000 sq ft $0 .028 x sq ft ❑ Sprinkler - Minor Modification <10 heads p ( ) $ 96 (inspection only) 84 ❑ Commercial Hood (New & UL 300 Upgrade Modification) Additional Hood $235 58 hood ❑ Commercial Hood - Minor Modificationadd move n02Zle ( / ) $ 96 (inspection only) 84 ❑ Spray Booth (New & Modification) $235 98 Aboveground Storage Tank (1 inspection per installation) AST $180/tank J/2j 1,- 82 ❑ Additional Tank ATI $ 96/tank 82 ❑ Aboveground Storage Tank (Removal, Mod,or Inspect'n) ATR $109/tank 82 ❑ Underground Storage Tank (Installation/Inspection) NI $878/tank 82 ❑ Underground Storage Tank (Modification) MOD $878/site 82 ❑ Underground Storage Tank (Minor Modification) MTM $167/site 82 ❑ Underground Storage Tank (Removal) TR $573/tank 84 ❑ Mandated UST Testing: Fuel Mont Cert/SB989/Cath. Prot. j NOTE: $96/hr for each type of test/per site/per UST system even if scheduled at the same time $ 96/hr (2 hrs minimum) _ $192 82 ❑ Oil well (Installation, Inspection, or re -inspection) X $ 96/hr 82 ❑ Tent # $ 96/tent $121/hr (2 hrs minimum) _ $242 84 ❑ After-hours inspection fee ❑ Pyrotechnic (1 permit per event, plus an inspection fee of $96/hr during business hours) Py NOTE: After.hours Pyrotechnic event inspection is @ $121./hr $ 96/hr 4 (5 hrs min standby fee/insp) _ $576 5 hrs min standby fee ins = $605 84 ❑ Re-inspection/Follow-up Inspection • $ 96/hr $ 96/hr 84 84 ❑ Portable LPG (Propane): # of Cages? ❑ Explosive Storage $235 84 ❑ Copying & File Research (File Research fee $57/hr) $0.25/page 84 0 Miscellaneous 84 Dyco Developments CHP Bakersfield Field & Dispatch Office Replacement 9855 Campagnoni St. Bakersfield, CA 93313- Peterson Hydraulics Job # 10-01-0165 • r r. a, r Aboveground Fuel Storage Tank Section # 35 5613 :x r_ a •• f Submittal # 1 .,Peterson Y draultds, Inc. 3 1653 W. El Segundo Blvd. Gardena; CA. 90249 (310) 323-3155 phone - (310) 323-3606 fax i Contractor License: 631515 www.petersonhydraulics. 6m t. , y "Providing. Service To The Vehicle Service Industry" July 20, 2010 - By: Dan Peterson 'r: Table of Contents Section Description Part # Tanks and Monitoring 335613 12,000 Gallon Modern Welding Fireguard MODTANK 12000 • Standard Fittings • 24" Manway 335613 Modern Welding Ground level fill system MODTANK • Baker 20 Gallon Containment box .1 • Check valve • Ball valve • Fill adapter • Dust cover '• Fill and vapor piping 335613 Modern Welding Galvanized end ladder MODTANK 335613 Morrison 8" Emergency vents - 8 oz. 244OM-0600AVEVR 335613 Morrison 8" Emergency vents - 16 oz. 244OM-0700AVEVR 335613 Husky Pressure/Vacuum vent 5885 335613 Morrison 2" Clock gauge i 818-0100AGEVR 335613 FE Petro 3/4HP Submersible turbine pump -AG STPAG75-VL2 335613 FE Petro Siphon cartridge kit 400137937 335613 FE Petro Smart controller with isolation box 402312921 335613 FE Petro Mechanical leak detector STP -MLD 335613 FE Petro Leak detector tee adaptor 400518001 335613 Morrison 2" Stainless steel ball valve 691 BSS -08001 V 335613 Flexing 2" x 18" MS x F Flex connector FF20X18M346XF 335613 Morrison 2" Solenoid valve 71 OSS -22001 V 120VAC - Stainless steel for E85 1. . 'Section Description 4 ' Part # I 335613•.... r , tHealyMini-jetty/siphon '-4 •; 9000-02 . - 335613 Healy Monitor System 6280A ' 6280 monitor 6275 vent sensor ` _ .. '.HPVV vacuum vent valve ; • System monitor control box ' 9800-1 pressure switch • HPV1.5 pressure vent valve ` (1) 9466 check valve: 335613 'Healy.Water-Column Gauge 939349A , +335613 Morrison 2" Check Valve-25`psi relief 530-0100AV `335613 Jomar 1/4" Ball Valve ':100-701 335613. Jomar 1" Ball Valve '100-705 335613, '' '.' Wayne Reliance 1 hose single product E/G6201D/27AGJK/JW1 • remote mechanical dispenser with 10:1 pulser " • internal filter 9 . AC junction box and hosmast= E85 compatible 335613. Healy. Standard coaxial hose _ 5' t 75B-050-S2S2. . 335613. � ..Healy breakaway ti 8701W; 335613 Healy Standard coaxial hose - 7" 75B-070-S2S2 . •335613 Healy 400 ORVR nozzle . 400-04FS 335613 Healy Hose adaptor CX6=A 335613 Bravo Aboveground dispenser containment box B-8600-1 PM ' 335613 OPW 1-1/2" Double poppet product impact.valve 10P -0152E85 - E85- 85_335613 335613 Vapor poppet P Pet roduct impact valve OPW P P : 60VSP-1001 335613 Bravo 2" Penetration FPF-8600 335613'. Flexing 1-1/2" x 18" M x MS Flex.connector FF15X18HMXM346 335613 Bravo Electrical fitting FEF -•EBS 1. . Section Description Part # 335613 VR - TLS -350 Monitoring console 848290-022 • with integral printer 335613 VR - Four input probe module 329356-002 335613 VR - Eight input sensor module 329358-001 335613 VR - Four relay output module 329359-001 335613 VR -.MAG Plus Probe 846391-4XX -for alternative fluids E85 w/o water detection 335613 VR - Probe Install Kit - Alternate fluid - E85 846400-004 - (no water float) 335613 Morrison Prober riser cap and adaptor 305XPA-1100AKEVR 335613 VR - AST Probe installation kit 312020-984 335613 VR- 2" Interstitial Sensor Cap 312020-928 335613 ,J VR - Interstitial sensor for steel tank 794390-420 335613 VR - Piping sump sensor 794380-208 335613 VR - Overfill Alarm 790091-001 335613 VR - Alarm acknowledgement switch 790095-001 335613 t Duro Air Water dispenser 50 1 i - PETROLEUM MARKETING EQUIPMENT .. Project Name: CHP - BAKERSFIELD # I QTY. PART # DESCRIPTION 1 1 MODTANK 0.2,000 Gallon i Modern Welding Fireguard,cylindrical AST(UL2085) with standard fittings, one 24" Manway. Tank mounted on steel saddles. Dimensions 10.5 OD x 24" 2 1 MODTANK Modern Welding Ground level fill system for E85 includes: overfill prevention valve, Baker 20 gallon containment box, check valve, ball valve, fill adaptor and dust cover. Fill and vapor piping from ground level to tank top (installed). 3 1 MODTANK Modern Welding Galvanized end laddder with sticking platform Tank Trim to be field installed - by others 4 1 2440M-0600AVEVR Morrison 8" Emergency vents - 8 oz. - male thread (secondary) 5 1 2440M-0700AVEVR Morrison 8" Emergency vents - 16 oz. - male thread (primary) 6 1 5885 Husky Pressure/Vacuum vent 7 1 818-0100AGEVR Morrison 2" Clock gauge 8 1 STPAG7541-2 FE Petro 3/4HP Submersible turbine pump -AG 9 1 400137937 FE Petro Siphon cartridge kit 10 1 402312921 FE Petro Smart controller with isolation box 11 1 STP -MLD FE Petro Mechanical leak detector 12 1 400518001 FE Petro Leak detector tee adaptor 13 1 691BSS-08001V Morrison 2" Stainless steel ball valve 14 1 FF20X18M346XF Flexing 2" x 18" MS x F Flex connector Note: Solenoid valve is shown in specification parts list, but not on plans - add the following SS valve if needed 15. 1 710sS-22001V Morrison 2" Solenoid valve - 120VAC - Stainless steel for E85 16 1 9000-02 Healy Mini jet w/siphon 17 1 6280A Healy Monitor System,includes ,6280 monitor,6275 vent sensor HPW vacuum vent valve,system monitor control box, 9800-1 pressure switch,HPV1.5 pressure vent valve and (1) 9466 check valve 18 1 939349A Healy Water Column Gauge 19 1 530-01ooAV Morrison 2" Check Valve -25 psi relief 20 1 100-701 Jomar 1/4" Ball Valve 21 1 100-705 Jomar 1" Ball Valve 22 2 E/G6201D/27AGJK/Jw1 Wayne Reliance 1 hose single product,remote mechanical dispenser with 10:1 pulser,internal filter,AC junction box and hos mast - E85 compatible YOUR VALUE ADDED PETROLEUM EQUIPMENT DISTRIBUTOR PME Equipment Sales PETROLEUM MARKETING EQUIPMENT PME Equipment Sales 232 Commercial Street Corporate Office 2190 Enterprise Blvd San Jose, CA 95112 - 740 Monroe Way West Sacramento, CA 95691 (408) 998.8205 Fax (408) 998.8249 Placentia, CA 92870 (916) 371.8271 Fax (916) 384-0298 (714) 577.7878 Fax (714) 577.7979 PETROLEUM MARKETING EQUIPMENT 23 2 75B-050-S2S2 Healy Standard coaxial hose - 5' 24 2 8701VV Healy breakaway 25 2 75B-070-S2S2 Healy Standard coaxial hose - 7" 26 2 400-04FS Healy 400 ORVR nozzle 27 2 CX6-A Healy Hose adaptor 28 2 B-8600-1 PM Bravo Aboveground dispenser containment box 29 2 10P -0152E85 OPW 1-1/2" Double poppet product impact valve - E85 30 2 60VSP-1001 OPW Vapor poppeted product impact valve 31 2 FPF-8600 Bravo 2" Penetration 32 4 FF15X18HMXM346 Flexing 1-1/2" x 18" M x MS Flex connector 33 2 FEF -EBS Bravo Electrical fitting 34 1 848290-022 VR - TLS -350 Monitoring console with integral printer 35 1 329356-002 VR - Four input probe module 36 1 329358-001 VR - Eight input sensor module 37 1 329359-001 VR - Four relay output module 38 1 846391-4XX VR - MAG Plus Probe for alternative fluids E85 w/o water detection 39 1 846400-004 VR - Probe Install Kit - Alternate fluid - E85 (no water float) 40 1 305XPA-1100AKEVR Morrison Prober riser cap anf adaptor 41 1 312020-984 VR - AST Probe installation kit 42 1 312020-928 VR- 2" Interstitial Sensor Cap 43 1 794390-420 VR - Interstitial sensor for steel tank 44 2 794380-208 VR - Piping sump sensor 45 1 790091-001 VR - Overfill Alarm 46 1 790095-001 VR - Alarm acknowledgement switch 47 1 50 Duro Air Water dispenser YOUR VALUE ADDED PETROLEUM EQUIPMENT DISTRIBUTOR PME Equipment Sales PETROLEUM MARKETING EQUIPMENT PME Equipment Sales 232 Commercial Street Corporate Office 2190 Enterprise Blvd San Jose, CA 95112 740 Monroe Way West Sacramento, CA 95691 (408) 998.8205 Fax (408) 998-8249 Placentia, CA 92870 (916) 371.8271 Fax (916) 384-0298 (714) 577.7878 Fax (714) 577.7979 1. 4 A 4 4 1. 4 A P�—•��i iiiTiir e I t' _ .._•444.. � �R{. . 1 1� . 9 '1710 1�1' .. , , , 18009221 UL • Protect t � 1. r TM 7M 5 'a The New Generation of fire -rated AST's, going far beyond those "first generations" tanks which were merely enclosed in concrete. Fireguard" was the first AST of its design to obtain a UL Listing for secondary containment. 0 Fireguard's secondary containment can be tightness tested on-site with standard testing procedures! Fireguard's exterior steel wall provides superior weatherability and low-cost maintenance. Unlike concrete, cracking or spalling will never be a problem! i 4 0 Fireguard's unique thermal insulating material is 75% lighter than concrete... Shipping, installation and relocation costs are reduced! 0 The Fireguard' technology is patented under U.S. Patent #5695089 and #5809650 for "Light- weight Double Wall Storage Tank." Fireguard' is a UL approved core component for the 2244 system listing. 1 Steel Secondary Tank built to UL standards Steel Primary Tank k!l standards Lightweight thermal insulation • Unique feature that helped Fireguard' exceed the UL 2 -hour fire test • Sufficiently porous to facilitate quick emergency venting and/or leak detection 3 , f • The secondary containment on certain designs 'Is tour Aboveground lank Lverything I 1 N'S. Cc gicrc tc d • Secondary containment is testable on-site using • The secondary containment on certain designs ` standard, economical testing procedures. may require elaborate and expensive procedures to be tested on-site. • Fireguard's steel outer wall -provides low-cost ` maintenance and protects the insulation •- Exposed concrete outer•wall is'susceptible to . material from weathering. -cracking, spalling and weathering- problems that are expensive to` correct and are usually not • An average 12,000 gallon Fireguard' weighs under covered by warranty. 30,000 pounds - well within the legal load limit ,for trucking. An average'12,000 gallon concrete-encased;tank ` weighs upwards of 100,000 pounds - imagine the hassles involved in handling that tank. FIREGUARDO: THE ONLY TANK THAT MEETS ALL OF THESE STANDARDS UI12080 Listed "Fire Resistant' Tanks for Flammable • International Fire Code. (IFC), 2000- Chapter 34 and Combustible Liquids .. , • ULC -S655 Underwriters Laboratories of Canada • UL -2085 Listed "Protected" Aboveground Tanks for Standard for Aboveground Tanks for Flammable and - Flammable and Combustible Liquids Combustible Liquids • Both inner and outer tanks built per UIr142 Standards . Other Standards... for Steel Aboveground tanks for Flammable and Com, , • Ballistics protection per UFC Article 79, and ` bustible Liquids _ per UL -2085 • Uniform Fire Code, 2000 Edition Article' 79 and UFC • Vehicle impact protection per UFC Article 79, and Standard 79-7 "Protected Tank" per UL -2085` UL -2244, Aboveground Flammable. Liquid Tank - • California Air Resources Board (CARB) testing • Systems, The Fireguard tank can be used as the requirements for air emissions primary storage containment • Steel Tank Institute (STI) Standard B41 for • NFPA 30 and 30A, 2000 Edition, National Fire.' Thermally Insulated Aboveground Storage Tanks ' Protection Associations • Many fire codes and environmental regulations will • NFPA 1, Uniform, Fire CodeT",*of the National Fire accept Fireguard© Secondary Containment Tanks as ,Protection Association, 2003 Edition Section. an alternate to diking requirements 3.3.199.5, "Protected Aboveground Tank" If your project is required to follow NFPA 30 or 30A guidelines.'.. Check with your area "Authority Having Jurisdiction" related to maximum allowable tank capacity for the class fuel being stored and secondary containment requirements. Fireguard® LIMITED WARRANTY Limitations of Liability and Disclaimer What is Covered by this Warranty Provided that the conditions set forth below are satisfied, the steel tank manufacturer identified with the tank (hereinafter referred to as "Warrantor") warrants the Fireguard® tank for 30 years following deliveryof the tank to the tank owner at the time of the original installation ("the Owner"), against any of the following events which may occur, provided the event occurs under operating conditions covered by this Warranty: (i) against release of stored product from any secondary containment tank; (ii) against failure of the primary tank caused by non -corrosion related cracking, breakup or collapse; and (iii) against internal corrosion as long as the product stored within the tank is compatible with steel. In addition, the Warrantor warrants the tank against failure due to defective materials and workmanship for up to 1 year following the delivery of the tank to the Owner. Conditions to Warranty Effectiveness The limited warranties set forth herein are subject to the following conditions: 1. The Fireguard® tank must be: (i) The Original Aboveground Installation within the Continental United States of America, Alaska, Hawaii, and the Commonwealth of Puerto Rico or Canada; (ii) the tank was fabricated by the Warrantor so as to meet the Fireguard® Specifications; and (iii) the tank was installed and maintained in accordance with theapplicable Fireguard® specifications and theapplicable Fireguard® Installation Instructions thatwere in effect on the date of shipment by the Warrantor, any subsequent maintenance procedures of which the Owner has written notice, and any applicable governmental codes and regulations. Refer to the Installation Instructions on the back of this document for technical requirements concerning relocation of this tank by the original owner, in order to retain warranty eligibility. Tanks remaining in their original installation location will retain warranty eligibility if the facility where the tank is installed is sold to a new owner. 2. This Limited W arranty is not valid unless, and until, the Warranty Validation Card is fully completed by the Owner and returned to Steel Tank Institute (STI) within 30 days after the date of tank installation, or 90 days after the Warrantor's shipment of the tank, whichever comes first. 3. Upon discovery of a suspected tank failure or leak by the Owner, the Owner shall give the Warrantor written notice of the suspected tank failure or leak and permit the Warrantor or its designated representative to inspect the tank site prior to, during and after excavation of the tank. The tank owner bears the responsibility to identify that the cause of the failure is from one of the events within the Conditions covered by the Warranty. 4. Upon the W arrantor's determination that the tank failure or leak is covered by this Limited W arranty, the W arrantor at its sole option shall: (1) repair the tank; or (2) replace it with a tank of approximately the same size, design, quality of material and workmanship specified for the original tank; or (3) refund the purchase price of the original tank. If the Warrantor is unable to repair or replace the tank, it shall refund the original purchase price of the tank. What is Not Covered by this Warranty W arrantor does not warrant any piping system or any other attachments connected with the tank. U nder no circumstances, shall the W arrantor be liable for (1 ) the cost of repair or replacement of any piping system or other attachments to the tank; or (2) labor costs or other installation costs for tank repair or replacement; or (3) damage to the tank or other property resulting from the accumulation of water in the tank; or (4) damage caused by other improper operating or maintenance practices; or (5) tank failure due to defective materials and workmanship later than one year following delivery of the tank to the Owner. This Warranty does not cover STI Generator Base Tanks. Limitation of Liability and Exclusion of Other Remedies and Damages The foregoing remedy of repair, replacement or refund shall constitute the sole and exclusive remedy to the Owner. Under no circumstances, shall the liability of the Warrantor, or its affiliates or subsidiaries, under this warranty, exceed the purchase price of the tank. IN NO EVENT SHALL THE WARRANTOR, OR ITS AFFILIATES OR SUBSIDIARIES, BE LIABLE FOR CLAIMS OF PERSONAL INJURY OR FOR SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS OR REVENUE, LOSS OF USE OF THE TANK OR ANY ASSOCIATED EQUIPMENT, COST OF CAPITAL, COST OF THE SUBSTITUTE EQUIPMENT, FACILITIES OR SERVICES, DOWNTIME COST, CLAIMS OF CUSTOMERS OF THE OWNER FOR SUCH DAMAGES, OR FOR DAMAGE TO PROPERTY, WHETHER SUCH CLAIM SHALL BE FOR BREACH OF CONTRACT, BREACH OF WARRANTY, NEGLIGENCE OR STRICT LIABILITY, AND WHETHER SUCH CLAIM ARISES OUT OF OR RESULTS FROM THIS LIMITED WARRANTY, OR EXPRESS OR IMPLIED WARRANTIES, OR FROM THE DESIGN, MAN UFACTURE, SALE, DELIVERY, RESALE, INSTALLATION, TECHNICAL DIRECTION OF INSTALLATION, INSPECTION, REPAIR, OPERATION OR USE OF THE TANK. Consumer Notice The exclusion of indirect or consequential damages and the limitation of implied warranties herein may not be applicable to purchasers who are deemed "consumers" and who reside in states that do not allow the limitation of implied warranties or the exclusion of indirect or consequential damages otherwise applicable to consumers. Moreover, if you are deemed a "consumer", you may have specific legal rights in addition to those set forth in this warranty, which rights vary from state to state. Disclaimer of Other Warranties THE FOREGOING LIMITED WARRANTY IS THE ONLY WARRANTY MADE. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Financial Assurance Warrantor may have purchased insurance to cover some of its warranty obligations under this Limited Warranty. Such insurance would provide financial assurance for Warrantor's warranty obligations, but would not insure the Owner directly. If the Warrantor has purchased such insurance coverage, the Owner may request that the Warrantor provide a certificate of insurance to evidence Warrantor's purchase of such insurance. Effective with installations on or after January 1, 2007. Item # 130-40-0005 1/1/07 Fireguard® (U.S. Pat. No.'5,695,089) INSTALLATION, TESTING & MAINTENANCE INSTRUCTIONS 1.0 TANK SITE EVALUATION AND PREPARATION PRIOR TO . ' retest. If the problem persists, contact the tank manufacturer. INSTALLATION 3.2.2.7 If no leaks are found, close valve C and slowly open valve B to pressurize the interstitial space 1.1 The foundation mat be designed to support the tank plus 100%'of its contents when full. The between the double walls of the tank foundation design shall also take into accourd the type of support that is being mod and the point WARNING: Do nolapplyair pressuretolhe Interstitial space betweenthe walls ofa doublewalltank bad associated with that support. The foundation Trey be constructed using concrete, asphalt, without air pressure in the prinery lank. Do not apply air pressure to the interstitial space that is • gravel orotherstable, material and mat include provisions in its design to prevent lank movement.-' higher than the air pressure in the primary lank. Darrege to the tank may result. The foundation should include any provisions necessary for seismic design. Pressure gauge 1 will indicatea slight drop in test pressure when valve B is opened, but should hold The foundation design must also include provision for dmir ing surface water away from the lank. t steady at the lower pressure. If the test pressure drops below the Minimum requirements, close A' 1.2 ' For tank installations without cathodic corrosion protection• the lank should be grounded in valve B, reconnect the air supply fine and slowly open valve A to increase the pressure in the U V acooNance with applicable electriraland fire code standards. primary lank Whenthe required pressure is indicated on gauge l close valve A, disconnect the test " 1.3 Where the steel lank body is in contact with the earth, use a zinc grounding rod. Do net use a air supply line. Open valve B to equalize pressure in the primary tank and the interstitial space. t copper grounding red. - Gauge 1 and gauge 2 should have the same pressure reading. I 1 1.4 Where the steel tank body is in contact with the earth or foundation, it should be protected from, 3.2.2.8 Close valve B. Hold the test pressure in the interstitial space for 1 lour minimum. A steady drop external corrosion. For external corrosion protection using cathodic corrosion protection, consult in pressure gauge 2 indicates there may be a leak in the interstitial space. Check the fittings. the applicable standards (i.e., National Association of Corrosion Engineers) to provide the tank with gauges, and then retest. If the problem persists, contact the tank rrenufacturer. 4 appropriate protection from lightning without interference with the corrosion protection. Steeltanks 3.2.2.8 Proceed to Section 3.2.3, 'Detection of Leaks' below. '- •' in contact with the earth should not use copper grounding. Refer to STI R863-89,'Recommended 3.2.3' Detection of Leaks Practice for External Corrosion Protection of Shop Fabricated Abovegmund Storage Tank Fisons.' ' 3.2.3.1 Irtmediately apply the leak test solution to the tank exteriorsurfaces, webs, fittings, etc. Checkfor 1.5 Tanks beaded in areas subject to flooding mat be protected against floatation. leaks. No leaks are allowed. If leaks are found, notify the tank rrenufacturer. If m leaks are found, 1.6 Aboveground tanks should;rot be located above underground utilities or directly beneath overhead testing of the tank is complete. power lines. - 3.2.3.2, Open valve C, then slowly open valve B to release the test air pressure. 1.7 '' Thetanksha6 be protected from vandalismand accidemaldamage inaccordancewbh allapplicable 3.2.3.3 With the tank depressurized, remove the test piping, temporary plugs, caps and seals. Reinstailthe codes, i.e., NFPA 30, NFPA 30A, UFC, etc. as well as local environmental regulations and safety f emergency relief vents, etc. which were removed in Section 3.2.1 above. Emergency vents are codes. Consult beat authorities before installing this tank. , required on both the primary tank and the secondary tank ' ' _ � WARMNG: Emergency relief vents must be operable to prevent causing tank failure by over - 2.0 _ TANK HANDLING t pressurization. 7 2.1 4 Do net handle or install the lankwithout having knowledge end experience in procedures involved 4 with proper and safe installation ofan aboveground tank used for storage of stable, flammable and •4.0 TANK PIPING AND ACCESSORIES / combustible liquids. + - 4.1 Install all permanent piping and fittings using compatible, -hardening thread seatam material. 2.2 ' Equipment for handing the tank shall be of adequate size to ifl and position the tank. DO NOT 4.2 An unused tank openings must be property sealed and tested to be Oquid and vapor light prior to DROP OR DRAG THE TANK. - putting the lank into service. r . 2.3 Tanks shall be carefully handled using cables or chains of adequate length (with spreader bars, if 4.3 , DO NOT WELD ON THE TANK, MODIFY OR PENETRATE THE TANK STRUCTURE IN ANY WAV necessary) and size. Attach to the tank using the Offing lags provided. Care should be taken that WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE TANK MANUFACTURER. • the angle between the two cables, at the fill point, shag be no greater than 60 degrees. 4.4• All tank accessories shall be installed as required per local codes. ArdFsiphondevices. overfill shut- yy 2.4 DO NOT HANDLE OR MOVE THE TANK UNLESS IT IS EMPTY. '. ft- . offs and alarms, vents gauges, emergency vents, etc, are common requirements for tanks storing i 2.5 This is a stationary tank. Do net use this tank for transport of any product. e motor fuels for the purpose of being dispensed into motor vehicles. - 1 T 3.0 TESTING _ t " ' 4 5.0 • LABELING - �' 3.1 General Roquiremonts - . 5.1 • Tames shat be labeled in accordance with all applicable codes. 3.1.1 t An on-site air test of the tank may be required by local authorities to ensure no damage has : occurred in shipping and handling. An testing shall be done as described below. - 6.0 MAINTENANCE • F r v 3.1.2 - Vacuum monitored double wall tanks are shipped from the rrenufaclurer white vacuumdrewnonthe 6.1 The tank operator should perform periodic walk -around inspections to identify and repairareas of • '� space between the wags. Read and record the vacuum pressure. If the vacuum gauge reading is i damage to the vessel or the mating itself and check for proper drainage around the tank area. '# less than 12 inches ` • 8.2 It is imperative that the tank exterior be inspected periodically to ensure that the integrity of the • ., .. coatingismaintained. The frequency of periodic repainting will be based upon environmental factors • H9 (40.5 kPa), mmect the original tank manufacturer. s r + in the geographic area where the tank is located. Special consideration should be given to the • 3.1.3 1, In lieu of the air pressure test described below, a vacuum may be applied to the interstice of a selection of the paint, surface preparation and coating application. The mating selected should be i double•wan tank or to the interstice of a double -bottom tank. DO NOT APPLY A VACUUM TO THE ` suitable for use with the current coating, or the existing coating should be reatoved. The mating ., PRI MARY TANK OF A DOUBLE-WALL TANK OR TO A SINGLE-WALL TANK. A vacuumof 7'to 10' •' selected should be of Industrial quality. Hg is to be applied to the interstice and held for at least 24 hours with re more than a 2• Hg vacuum 6.3 Proper site preparation and maimerance are vital to ensure drainage of surface water. Should i 'loss allowed. If this vacuum cannot be held for 24 hours, then perform the air lest procedure '4. ground conditions change or settlement occur, take the appropriate steps to maintain proper described below. „ - / '• f, drainage and prevent standing water near or under the tank area. , 7 3.1.3.1 • Caution mat be taken in applying a vacuum to the interstice of a tank and the testing must be - stopped if any deforrmation appears on the tank.1 6.4 The primary tank shall be inspected monthly for the presence of waterat the lowest possible points, inside the primary tank Remove any "ter found. Water and sediment in fuel can muse phgging 3.2 �. Air Pressure Test Procedure for Tanks ° of filters. Also, bacterial growth, originating from the fuel can cause corrosion of tanks and fires. 3.2.1 Remove emergency vents and cap openings to hold tank pressure as required.. For procedures on low to check for the presence of water and removal of water, refer to API NOTE: Use only calibrated air pressure gauges with a 0-15 prig (0-103 kPa)dial span. The re6ef Y Recommended Practice 1621, Appendix D and API Standard 2610. Another source of imomution ' valve mat have a lbw rate at the set pressure that is greater than the flow rate of the air supply , is a report by the US Department of Energy Brookhaven National Laboratory, BNL 48406, widen fins. The regulated air supply lest pressure lead for this test should be as follows: provides information on methods to test for and remove water, test for bacterial presence in fuel, ' a. ' Horizontal cylindrical tanks- Not less than 3 psig (20.7 kPa) nor mm than 5 psig(34.5 kPa). Set tank cleaning and fuel additives. - ' the pressure relief valve in the test air supply One at 5.5 psi (38 kPa). - m 6.5 • This tank must be removed from service if darreged by fire exposure, other physical means or b. _ _ Vertical tanks -Not less than 1 Y prig (10.4 kPa) nor more than 3 psig (20.7 kPa). Set pressure misuse. - t relief valve in test air supply line at 3 psig (20.7 kPa). 6.6 Failure to adhere with these maintenance instmctiom Trey void your warranty. c. Roctengulartenks-Not more than 3 psig(20.7 kPa). Set pressure relief valve in test air supply line 6.7Tenk relocation requirements , often aboveground storage tanks are relocated. The following ' at 3 psig (20.7 kPa).' instructions are to be followed when this occurs: All steps are to be documented and the CAUTION: Do not leave pressurized tank unattended while the pressure linetairOne is connected.' documentation is to be kept for the life of the tank. ' • Do not stand in front of tank heads or fittings when pressurizing tank • 6.7.1 The hazards associated with the cleaning, entry, inspection, testing, maimerance or other aspects Pressurizing of large tanks my result in the slight deformation of the lop and of ASTs are significant. Safety consideration and controls should be established prior to ? bottom of vertical tanks. ofthe sides of rectangular tanks, and of the heads and ends of cylindrical undertaking physical activities associated with ASTs. Cleaning oftanks mat be per state and bml tanks. Should deformation appear severe, immediately refeve the pressure. jurisdiction requirements. • 3.2.2 , Tank Pressurizing Procedure 6.7.2 Referto the STI Standard SP001,'Standardforthe hupectionof Aboveground Storage Tanks•for 3.2.2.1 r The following air pressure testing does net apply to double -wag tanks equipped with interstitial requirements concemirgtankinspections. This SP001 Standamdetailsregtirememsforimpecliom .f vacuum monitoring system. (in lieu of the air pressure test, the tank Trey be shipped from the based on the tank installation and age. A tank must undergo • 1 factory with a vacuum in the tank interstice. Readandrecomthevacuumpressure. Ifthevacuum• the appropriate inspection prior to relocation. - r 1 pressure gauge reading is less than 12 inches Hg (40.5 kPa), contact the tank mnufacturer). 6.7.3 In addition, the tank must he subjected to a pressure (or vacuum) test as detailed paragraph 3.2 3.2.22 -V Instal test piping as shown in Figum2. Close valves Aand B. Openvalve C. Temporarily plug, cap' •.._ above exceptan inert gas, such as nitrogen, should be usedfortanks that have previously heldfuel. `' or seal off remaining tank openings to hold pressure. • - " ' 3.2.2.3 Connect the regulated test air supply One to lest piping as shown in Figure 2. Disclaimer, 3.2.2.4 • ama Close vlves B and C. Slowly open valve A to pressurize the priry tank. Pressure gauge 1 should indimte test air pressure given in Section 3.2.1 above.- ,r These insre tructions aintended only as an aid to tank installers who are knowledgeable and experienced in aboveground tank installation. Compliance herewith does net necessarily meet the requirements of applicable 3.2.2.5 Close valve A. Disconnect the regulated test air supply One from the test piping. -- federal, state and local laws, regulations and ordinances coreeming tank installation. STI makes nowarranties, • 3.2.2.6 Monitortest pressure in the printery tank for 1 hourminimrm. A steady drop in pressure reading for express or implied, including but net firlited to, any implied warranties of merchantability or fitness for a particular • gauge 1 indicates there may be a leak in the primary tank Check the fillings, the gauge, and then r purpose, as a result of these installation instructions. 4 • _ • f i y i These instructions are intended only as an aid to tank installers who are knowledgeable and experienced in aboveground tank installation. Compliance herewith does not necessarily meet the f requirements of applicable federal, stale and local laws, regulations and ordinances concerning tank installation. STI makes no warranties, express or implied, including but not limited to, any implied + warranties of merchantability or fitness foe a particular purpose, as a result of these installation instructions. + ' • - This information furnished as a service of a Steel Tank Institute member. . t Firewty ©Copyright Steel Tank Institute. All rights reserved for exclusive use of Fireguard® licensees. 02/07 MEETS 2007 CBC 1 8" GALVANIZED LADDER MATERIAL AND CONFORM MEETS 2006 IBC 24" AND PLATFORM O UNDERWRITERS FNPT FILL QTY. SIZE TYPE REMARKS LABORATORIES STANDARD INNER TANK: PER U.L. U.L. 2085. SECONDARY CONTAINMENT PROTECTED OUTER TANK: PER U.L. I ABOVEGROUND TANK, 3I LATEST EDITION. INTERIOR: BARE, CLEAN OF I U.L. LABEL FOR PROTECTED DEBRIS Q � 000 Q SECONDARY EXTERIOR: WHITE EPDXY THIS SIDE WITH CONTAINMENT I I REMOVEABLE CHAINS ABOVEGROUND TANK IS IN PLACE OF RAILING REQUIRED. I I CARB EXECUTIVE ORDER — — — — — VR -302 C. F- 114"ID cio:cA —MM A, ) C - 1191" 1352" F 8- 1 1/4" HOLES BASE PLATE DETAIL TYPICAL OF FOUR PER SADDLE SIZE I O.D. I LENGTH I WEIGHT 12,0001121'1 23'-4" 33,000# MANWAY FNPT MNPT MONITOR FNPT FNPT 1 8" lFNPT I SECONDARY E-VEI 1 8" FNPT PRIMARY E -VENT 1 4" FNPT 1 4" FNPT 1 6" FNPT FILL QTY. SIZE TYPE REMARKS SCHEDULE OF OPENINGS CONNECTING AIR TEST AT NOT LESS THAN 3 PSI NOR MORE THAN 5 PSI. PRIMARY TANK TO BE TESTED ALONE. SECONDARY TANK TO BE PRESSURE TESTED WITH PRESSURE IN PRIMARY TANK. THIS SHALL BE ACCOMPLISHED BY BLEEDING AIR FROM THE PRIMARY TANK INTO THE SECONDARY TANK. AT NO TIME SHALL THE PRESSURE IN THE SECONDARY TANK EXCEED THE PRESSURE IN THE PRIMARY TANK. No. REOD.: ONE (1) (ITEM NO,; FG12000 mode modem welding company of california, inc. 4141 N. RRAIVI.EY AVE FRESNO. CA 93712 1'11.55?275.9353 FAN55%2754331 P.M.E. 12,000 GALLON MODERN FIREGUARD TANK California Highway Patrol MOJAVE, CA 0". er RB I.,E 11/18/13 1 =.z- NONE a1R BY rue — BAc. No 12488 APR BY P.O. Ne. W. NO. 1 OF 1 1504 FLANGE HAND �\ / PUMP \ / CHECK \ � VALVE VAPO 1 \ ECOVERI I BALL PORT VALV j 1 / \ �II \� SPILL BOX CHECK VALVE VAPOR RECOVERY ADAPTER AND CAP GROUND LEVEL FILL EQUIPMENT -GASOLINE I I II j \OVERFILL i II11 VALVE IIU CHECKI I VALVE I II I II I 11 I II Morrison 927 - 0300AAEVR - Fill Adaptor Morrison 735DC-4000ACEVR - Fill Cap Morrison 158A-0800AV - 3" Vertical check valve Morrison 9095AA3300AVEVR - 3" Overfill prevention valve Morrison 419-03101TEVR - 3" x 10' Drop tube Morrison 323-0400AAEVR - 4" x 4" Vapor adaptor Morrison 323C-0100ACEVR - Vapor cap Fill -Rite 151 Handpump Goodyear 532-327-024 Flexsteel 3/4" x 2' Hardwall hose Baker Industries 20 Gallon Spill Containment Box CARB Phase I EVR VR -402-A AST Certified Products! The Morrison 927 dry disconnect adaptor is installed at the fill point in the fill line of a fuel storage tank system. The internal spring loaded poppet assembly remains closed providing a liquid -tight seal when not connected to a dry disconnect adaptor. Morrison 928 dry disconnect coupler is installed on the end of delivery vehicle hose. When coupled, the 927 and 928 provide a liquid -tight connection enabling a dry connection and a dry disconnection. The 725DC dust cap serves as a protective cover for the 927 adaptor when not in use. SPECIFICATION OPTIONS A—Threads: 1.5" NPT (1 N); 2" NPT (2N); 2" NPS (2S); 3' B—Body: Hard coated aluminum (A); Brass (B); Stainless C—Seals: Viton (V); Buna (B) D—EVR: Yes (Y); No (N) Fig. 927 I.D. Number Description A B C D CAP SIZE WT 927--0200AAEVR 2" Dry Disconnect Adaptor, Alum w/Viton, CARB EVR approved 2S A V Y 2.5" 1.98 927---0300AAEV7R 3 -_Dry Disconnect Adaptor, Alum w/Viton, CARB EVR approved 3N OA @ lU C4l 3.5 927--0400AAEVR 4" Dry Disconnect Adaptor, Alum wNiton, CARB EVR approved 4N A V Y 4" 3.5 9095A5201AAEVR I 4"x2" Dry Disconnect Adaptor, Alum w/Viton, CARB EVR approved 4N A V Y 2.5" 2.5 928 --- 0150ACEVR 1'/s" Dry Disconnect Coupler, Aluminum with Viton, CARB EVR approved 1 N A V Y 2" 4.4 928--0200ACEVR 2" Dry Disconnect Coupler, Aluminum with Viton, CARB EVR approved 2N A V Y 2.5" 6.0 928--0300ACEVR 3" Dry Disconnect Coupler, Aluminum with Viton, CARB EVR approved 3N A V Y 4" 12.6 ADAPTOR SIZE 735DC-2000ACEVR 2" Dust Cap, use w/ 1.5" 927 Adaptors - Alum., CARB EVR approved A B Y 1.5" 1 735DCA2000ACEVR 2" Dust Cap, use w/ 1.5" 927 Adaptors - Anod. Alum., CARB EVR approved A B Y 1.5" 1 735DC-2500ACEVR 2.5" Dust Cap, use w/ 2" 927 Adaptors - Alum., CARB EVR approved A B Y 2" 1.25 735DCA2500ACEVR 2.5" Dust Cap, use w/ 2" 927 Adaptors -Anod. Alum., CARB EVR approved A B Y 2" 1.25 735DC-3000ACEVR 3" Dust Cap, use w/ 3" & 4" 927 Adaptors -Alum., CARB EVR approved A B Y 3" & 4" 1.5 735DCA3000ACEVR 3" Dust Cap, use w/ 3" & 4" 927 Adaptors - Anod. Alum., CARB EVR approved A B Y 3" & 4" 1.5 735DC-4000ACEVR 4" Dust Cap, use w/ 3" & 4" 927 Adaptors - Alum., CARB EVR approved rA BB nYj 3" & 4" 2.5 735DCA4000ACEVR 4" Dust Cap, use w/ 3" & 4" 927 Adaptors - Anod. Alum., CARB EVR approved A B Y 3" & 4" 2.5 UMorrison Established 1855 Bros. Co. P.O. Box 238 • Dubuque, Iowa 52004-0238 563.583.5701 (tel) • 800.553.4840.563.583.5028 (fax) www.morbros.com VALVES & FITTINGS 15gq ' Vertical Check Valve Single poppet, one-way check valve used to. prevent backflow in supply lines or used as a ' prime holding valve in suction systems. , Features • Soft seat - • Thermal expansion available (25 or 50 PSI approximate) • '/2 to 2 PSI spring setting 158A (3") , Construction Details 158A-0300 AV [ 'W I 1.25 Body... Brass f 158A-0400 AV 1" 1.75 ' Cap... Brass 158A-0600 AV 2" 5.75 Plunger... Brass L58A-0800 AV 3©" 15.0 Spring... Stainless steel ( onsu nce is . or a on , ion , an expansion relief options. - f Discs... Buna-N (Viton® and Teflon® —• available) NOTE • Expansion valve... Brass with' • t Opening pressure settings are approximate. Viton® r 158B Back Pressure Check Valve Single poppet; one-way check valve used to maintain product flow in direction. Heavy + + •spring for back pressure applications. c .N. eat es al -4o -metal seats Therm xpansion available (25 or I approximate) , • 5 to 7 PSI s settings 1588 (3':)'+ M MMM I Construction Details _ i561343 'Y.^ 1.25 ' Body... Brass 15BB-0400 AV 1.75 t Cap... Brass 15813-06004V 2" 5.75 , Plunger... Brass 1588-0800 AV 3" 15. Spring... Stainless s -. `Consult Price List for other expansion relief optio Expansion v ... Brass with, - V' { .. NOTE Opening pressure settings are approximate. . -24- }s www.morbros.com uModel 9095AA Overfill Prevention Valve The 9095AA Overfill Prevention Valve is installed at the fill port of a storage tank. Used in a pressurized tight fill application, the valve helps prevent tank overfills by closing when the liquid level reaches a pre- set warning level (90-95% full). The valve is installed on a standard 6" NPT male connection and has a built-in bleed hole that allows the fill hose pressure to be relieved after the valve closes. This bleed hole also provides anti=siphon protection for the valve. When installed to manufacturer requirements, the Morrison Fig. 9095AA Overfill Prevention Valve can eliminate hazardous liquid spills. The valve can be used in conjunction with the Morrison Fig. 516, 518, and 515 lines of AST Spill Containers or the Morrison Fig. 715 Remote Fill Port for added spill protection. All models are supplied with an adaptor to mount Morrison Fig. 419 aluminum drop tubes. A test mechanism is also sold separately. The test mechanism allows a technician to pull on the test line at any time during the filling process to actuate the float and stop the fill. This allows a technician to verify the valve is working properly. Product Warnings and Cautions • 5 PSI & 5 GPM is the minimum flow requirement for valve operation. Valve will NOT function in gravity fill applications. • Maximum viscosity (in centistokes): 3" Valve -300. • The estimated flow rate is 550 GPM at 10 PSI pressure drop. • Once closed the valve will allow flow of less than 2% of max flow to relieve fill line pressure. • A tight fill is required for the valve to operate. Do not substitute any other fill adaptors for the special adaptor supplied. • The valve must be used with clean product. Debris from products such as contaminated used oil may cause the valve to function improperly. • The valve can be used with 6" Sch. 40 or 80 pipe. NOTE • These valves are rated for a maximum pressure of 100 PSI. Failure to follow any or all of the above warnings may render the valve • Not suitable for motor oil or other heavy oils. non-functional and could result • Consult Morrison Bros. Co. for product compatibility with the valve. in an accidental product Spill, property SPECIFICATION SHEET Code Compliance NFPA 30, 30A, UFC, IFC and PEI/RP2000 E'R damage, fire, explosion, injury or death. I.D. Number Size Description Weight AV 3" AST Overfill Prevention Valve, Aluminum Body, w/ 3" Male Quick Disconnect x 6" Female Threads 21 lbs 9095AA3300 AV 3" AST Overfill Prevention Valve, Aluminum Body with 3" Female Threaded x 6" Female Threaded Connections 30 lbs 9095AA3300AVEVR 3' AST Overfill Prevenf'ion Valve, Aluminum Body with 3' Female Threaded x 6" Female Threaded Connection , CARB EVR Approved 30 lbs 9095AA9300 AV 3" 1 AST Overfill Prevention Valve, Aluminum Body, Less Top Connection 14.4 lbs 19095 9300AVEVR 3" 1 AST Overfill Prevention Valve, Aluminum Body, Less Top Connection, CARB EVR Approved 14.4 lbs 57o E. 7th Street, P.O. Box 238 1 Dubuque, IA 52004-0238 t. 563.583.5701 1 800.553.4840 1 f. 563.583.5o28 MORRISONBROS. CO. www.morbros.com 7 419---D3121TEVR 3" x 12' AL 419A--02041TEVR 2" x 4' AL 419A--02061TEVR 2" x 6' AL 419A--02121TEVR 2" x 12' 'AL' L• 419.A-,03101TEVR 3" x 10' AL. 3.31" 2.2" 2.2" .2.2" 3.31" 0.015 0.015 0.015 0.015 0.015 The Fig. 419 Drop Tube directs product flow`to liquid level when filling a storage tank. The drop tube prevents free fll and reduces agitation of liquid when filling. The flanges fits between tight, fill adaptor riser .� pipe. The tube extends to near bottom for submerged fill; : = 419A--03121TEVR 3" x,1 2' AL 3.31". 0:015 1 2.946 0:01,5: ' : All Morrison Drop Tubes are extruded aluminum. 0.003: 12 feet 9 419A:-0500 1TA 4"x 15' AN - 0.015, 3:875- t The 2" and.3",drop tubes can also be attached to the Morrison fig. 9095A AST Overfill Prevention Valve. 0.062:._ 0.007 115 feet E10.5; 1 EVR approved models available.' . SPECIFICATION OPTIONS: :-UMorrison-Bros. Co:: • ` A -Size C=F•Iange OD F -Tube ID,+ / = 1=0AL Length 13 -"Aluminum (AL) `" D -Flange OD +:/ - ;. G -Wall WT.-Weight:(Lb.) or Anodized (AN) E -Tube ID: H=:Wall + ` I ► -' I.D. Number, A B C C E' F G H I Wt. 419---0600 1T ::: 2" x 4' AL 2.2" 0.015 1.906 + 0.062- -.000 0.062 + 0.006:-.010 4 feet 1.75 419---0700 IT 2" x 6' AL 2.2" .. 0.015 1.906 + 0.062 .000 .0.062 +0.006 -:01.0.. 6 feet 2.5 - K ` 419-=70100 1 T. 2" x 12' AL 2:2" 0.015 1.906 + 0.062 -.000 0.062 +0.006 -.010 ,12 feet 5 .:. 419---0200 1T; 3" x 10' 'AL 3.31" 0.015 1 2.946 0.01.5: , : 0.063 0.003' 10 feet -6.6 419---1400 1T 3" x 12' AL 3.31" 0.615 2.946 0.015 0.063 0.003 12 feet 9 419==-1000 1T 4" x 4' 'AL 4.22" 0.015 3.875 .:- 0.023 0.062:.", .0.007 4 feet, 5.5- .5'419---0900 41 --- 09001 T 4" x-5; AL 4.22" `0.015 3.87S 0.023 0.007 5 feet • 6 .. • _0.062 ... ; .419 --- 0800 1 T.. t. .. 4" x 7' AL 4.22" 0.015 3.875 0.023 0.062 0.007_. " • 7 feet 7.5 • ' ' 419-=-0300 1.T 4" x 10' AL 4.22' 0.015 3.875 0.023' 0.062 .. 0.007 10 feet 9 419_---0400 IT 4" x 12' AL 4.22" 0.015 3.875 0.023. 10062 0.007 12 feet 12 ' F 419=--0500 1 T 4" x 15' AL 4.22". 0.015 3.875 0.023•" ;• 0.062 0.007: 15 feet • •: 10.5 419 --- 02041TEVR -2" x 4' AL 2.2" 0.015 •1.906 + 0.062' -.000 0.062 .+,0.006 -'010' 4 feet 1.75 419-'=02061TEVR 2'' x 6' AL 2:2" 0.015 1.906 +0.062 -.000 0.062. + 0.006 -.010 6 feet 2.5 ::. 419 --- 02121TEVR 2" x 12' AL 2.2", 0.015 1.906 + 0.062,.-:010.0 0.062 + 0.00.6.-.01 12 feet 5 ' 419---03101TEVR. ,3'_ 1x 0 AL 3.37 `0:015. ,2.946 0.015,.... 0.063 0.003 ..... 10feet 6.6 419---D3121TEVR 3" x 12' AL 419A--02041TEVR 2" x 4' AL 419A--02061TEVR 2" x 6' AL 419A--02121TEVR 2" x 12' 'AL' L• 419.A-,03101TEVR 3" x 10' AL. 3.31" 2.2" 2.2" .2.2" 3.31" 0.015 0.015 0.015 0.015 0.015 2:946. 1.906 1.906 1.906. .2.946 0.015 '. + 0.062 .000 + 0.062 =.000 + 0.062 '.000 0.015 0..06.8'['+. 0.062 0.062 0.062 0.063 •0.003 '• 12 feet 9 - + 0.006 7.010 4 feet 1.75 . + 0.006 =;010 6 feet '2.5 +'0.006 -.010 12 feet 5 ....,.0.003 10 feet 6.6 : = 419A--03121TEVR 3" x,1 2' AL 3.31". 0:015 1 2.946 0:01,5: ' : 0.063 0.003: 12 feet 9 419A:-0500 1TA 4"x 15' AN 4.22" 0.015, 3:875- ,.. 0.023 0.062:._ 0.007 115 feet E10.5; 1 :-UMorrison-Bros. Co:: • P.O. Box Dubuque,. 52004-0238 ' Established 1855, 563.583.5701 (tel) • 800.553:4840.56i583.5028_(fax) 4 www.morbros.com The Morrison 323 Series Adaptors are designed for installation on aboveground and underground storage tanks to mate with vapor recovery couplers & elbows. This connection allows the fuel vapors to be returned to the tank truck during the fuel delivery operation. The 323SA model has a built in swivel. The 323B model is equipped to accept brake interlock devices which lock the transport brakes while connected. The Morrison 323C Caps provide a lockable vapor tight cover which protects the adaptor from dirt and debris. SPECIFICATION OPTIONS: A—Threads: 3" NPT (3N); 3" NPS (3S); 4" NPT (4N); 4" NPS (4S); 3" BSP (3B) B—Gasket: Buna (B); Viton (V) C—Adaptor Size D—Disc: Buna (B); Viton (V) E—Body: Hard coated aluminum (A); Brass (B); Epoxy Coated Aluminum (AE) F—EVR: Yes (Y); No (N) G—Brake: Yes (Y); No (N) OAH—Overall Height (in inches) WT.—Shipping Weight (in pounds) 323B 323SA 323C I.D. Number Description A B C D E F G OAH Weight 323 --- 0100AA Vapor Recovery Adaptor (4" Vapor, 3" Riser Thread) 3N N/A 4" B A N N 5.44 3.34 323---0200 AA Vapor Recovery Adaptor 4S B 4" B A N N 5.88 4 323---0300 AA Vapor Recovery Adaptor (Viton) (4" Vapor, 3" Riser Thread) 3S B 4" V A N N 5.63 3.34 323--0300AAEVR Vapor Recovery Adaptor (4" Vapor, 3" Riser Thread) EVR 3S B 4" V A Y N 5.48 3.5 323--0400 AA Vapor Recovery Adaptor (Viton) 4S B 4" V A N N 5.94 4 323 - 0400AAEVR Vapor Recovery Adaptor (4" Vapor, 4" Riser Thread) EVR 4S B 4" V A Y N 5.94 4.4 323BSPO100 AA Vapor Recovery Adaptor w/Brake Int. - Alum (Viton) BSP Threads 4S N/A 4" V A N N 5.88 3.34 323BSP0200 AA Vapor Recovery Adaptor w/Brake Int. - Alum (Viton) BSP Threads 4S N/A 4" V A N N 5.88 4 32313-0050 AA Vapor Recovery Adaptor w/Brake Interlock - Aluminum 3N N/A 4" B A N Y 5.88 4 3236--0100 AA Vapor Recovery Adaptor w/Brake Interlock - Aluminum 4S B 4" B A N Y 5.88 4 323B--0200 AA Vapor Recovery Adaptor w/Brake Interlock - Aluminum (Viton) 4S B 4" V A N Y 5.88 4 32313--0300 AA Vapor Recovery Adaptor -w/o Internal Poppet Assy -Aluminum 4S B 4" A N Y 5.88 4 323SA-0200 AA Vapor Recovery Adaptor - Swivel Type, Brass 4S B 4" V B N N 5.63 10.9 323C--0100 AC Vapor Recovery Cap B 4" AE N 1.75 323C-0100ACEVR Vapor Recovery Cap - CARB EVR Approved B 4" AE Y 1.8 UMorrison Bros. Co. Established 1855 P.O. Box 238 • Dubuque, Iowa 52004-0238 563.583.5701 (tel) • 800.553.4840.563.583.5028 (fax) www.morbros.com FILL=RITE, SERIES 5200 PISTON HAND PUMP Owner's Operation & Safety Manual Models FR150, FR151, FR152, FR156 SAFETY INSTRUCTIONS To ensure safe and efficient operation, it is essential to read and follow each of these warnings and precautions. 1. Improper use or installation of this product can cause serious bodily injury or death. 2. Do NOT smoke near pump or use pump near an open flame when pumping flammable fluids. Fire could result. 3. A Fill -Rite filter should be used on pump outlet to ensure that no foreign material is transferred to fuel tank. 4. Use gasoline and oil resistant thread sealant or sealant tape on all threaded joints to protect against leakage. 5. Storage tank or barrel should be anchored to prevent tipping in both the full and empty conditions. 6. To minimize static electricity build-up, keep nozzle in contact with container being filled. WARNING This product should not be used for fluid transfer into aircraft. This product is not suited for use with fluids for human consumption or fluids containing water. Fluid Compatibility If in doubt about compatibility of a specific fluid, contact supplier of fluid to check for any adverse reactions to the wetted materials. The 5200 is compatible with the following fluids: • Gasoline, Diesel, Heptane, Kerosene, Stoddard Solvent, Light Oils, Mineral Spirits Do NOT use the 5200 with the following fluids: • Water, SulfuricAcid, Naptha, Methanol, Methyl Ethyl Ketone (MEK), Acetone, Ammonia, Benzene, Bleach, Chlorine SAFETY APPROVAL U� usno INSTALLATION NOTE: All pipe threads must have a sealant to protect against leaks. Use sealant tape provided with the pump, or use a gasoline and oil resistant thread sealant. 1. Screw suction pipe into pump inlet flange and tighten. 2. Extend suction pipe into tank or barrel opening to within 3" of bottom of tank or barrel. Do not rest suction pipe on bottom. 3. Screw inlet flange of pump completely and securely into undamaged tank or barrel bung. PUMPS WITH HOSE AND NOZZLE 4. Screw one end of hose into pump discharge opening and the nozzle to other end of hose. PUMPS WITH DISCHARGE SPOUTS 4. Screw discharge spout assembly into top of pump. PUMPS WITH METER, HOSE AND NOZZLE 4. Screw street elbow into top of pump, nipple into street elbow, meter onto nipple. Note: Position the meter to the right of the handle facing operator for ease of operator viewing. Screw one end of hose into meter outlet and the nozzle to the other end of hose. PUMP FLOW REVERSAL INSTRUCTIONS Rotating the piston 180° inside the pump will reverse the flow of the pump. NOTE: Removing the piston is not required to complete this process. 1. Remove the linkage pin (item 14) that retains the links (item 13) on the piston (item 3). 2. Using a wrench, rotate the piston 180°. Take care to avoid scratching the piston shaft. 3. Reattach the links (item 13) using the removed linkage pin (item 14). 4. Remove the Anti-SiphonValve (item 25) and replace with 3/4" NPT pipe plug. OPERATING INSTRUCTIONS 1. Reset meter to 0 (if applicable). 2. Insert nozzle into tank (if applicable). 3. Operate handle to begin fluid flow. 4. When finished pumping, allow hose to drain and return nozzle to nozzle boot. TROUBLESHOOTING IF PUMP FAILS TO PRIME: Check suction line for leaks or obstructions. Check valves and piston for nicks, burrs or wear. Check gasket for leakage. LOW PUMPING CAPACITY: Remove and clean screen. Checkforleaks in suction line. PUMP FLUID LEAKAGE: Tighten bearing nut 1/4 to 1/2 turn. Replace packing. Replace anti -siphon valve. Tighten covers and joints. SERIES 5200 PISTON HAND PUMP Owner's Operation & Safety Manual Models FR150, FR151, FR152, FR156 SAFETY INSTRUCTIONS To ensure safe and efficient operation, it is essential to read and follow each of these warnings and precautions. 1. Improper use or installation of this product can cause serious bodily injury or death. 2. Do NOT smoke near pump or use pump near an open flame when pumping flammable fluids. Fire could result. 3. A Fill -Rite filter should be used on pump outlet to ensure that no foreign material is transferred to fuel tank. 4. Use gasoline and oil resistant thread sealant or sealant tape on all threaded joints to protect against leakage. 5. Storage tank or barrel should be anchored to prevent tipping in both the full and empty conditions. 6. To minimize static electricity build-up, keep nozzle in contact with container being filled. WARNING This product should not be used for fluid transfer into aircraft. This product is not suited for use with fluids for human consumption or fluids containing water. Fluid Compatibility If in doubt about compatibility of a specific fluid, contact supplier of fluid to check for any adverse reactions to the wetted materials. The 5200 is compatible with the following fluids: • Gasoline, Diesel, Heptane, Kerosene, Stoddard Solvent, Light Oils, Mineral Spirits Do NOT use the 5200 with the following fluids: • Water, SulfuricAcid, Naptha, Methanol, Methyl Ethyl Ketone (MEK), Acetone, Ammonia, Benzene, Bleach, Chlorine SAFETY APPROVAL U� usno INSTALLATION NOTE: All pipe threads must have a sealant to protect against leaks. Use sealant tape provided with the pump, or use a gasoline and oil resistant thread sealant. 1. Screw suction pipe into pump inlet flange and tighten. 2. Extend suction pipe into tank or barrel opening to within 3" of bottom of tank or barrel. Do not rest suction pipe on bottom. 3. Screw inlet flange of pump completely and securely into undamaged tank or barrel bung. PUMPS WITH HOSE AND NOZZLE 4. Screw one end of hose into pump discharge opening and the nozzle to other end of hose. PUMPS WITH DISCHARGE SPOUTS 4. Screw discharge spout assembly into top of pump. PUMPS WITH METER, HOSE AND NOZZLE 4. Screw street elbow into top of pump, nipple into street elbow, meter onto nipple. Note: Position the meter to the right of the handle facing operator for ease of operator viewing. Screw one end of hose into meter outlet and the nozzle to the other end of hose. PUMP FLOW REVERSAL INSTRUCTIONS Rotating the piston 180° inside the pump will reverse the flow of the pump. NOTE: Removing the piston is not required to complete this process. 1. Remove the linkage pin (item 14) that retains the links (item 13) on the piston (item 3). 2. Using a wrench, rotate the piston 180°. Take care to avoid scratching the piston shaft. 3. Reattach the links (item 13) using the removed linkage pin (item 14). 4. Remove the Anti-SiphonValve (item 25) and replace with 3/4" NPT pipe plug. OPERATING INSTRUCTIONS 1. Reset meter to 0 (if applicable). 2. Insert nozzle into tank (if applicable). 3. Operate handle to begin fluid flow. 4. When finished pumping, allow hose to drain and return nozzle to nozzle boot. TROUBLESHOOTING IF PUMP FAILS TO PRIME: Check suction line for leaks or obstructions. Check valves and piston for nicks, burrs or wear. Check gasket for leakage. LOW PUMPING CAPACITY: Remove and clean screen. Checkforleaks in suction line. PUMP FLUID LEAKAGE: Tighten bearing nut 1/4 to 1/2 turn. Replace packing. Replace anti -siphon valve. Tighten covers and joints. F5200KTF18281 Repair Kit (Includes items 4, n Transfer Systems 5, 7, 10, 11, 12, 15 & 25) e VA"uthill.com 807CMK I Gallon Meter Kit 807CLMK I Liter Meter Kit F181 OPMO Particulate Filter Kit F181OHMO Hydrosorb (Water) Filter Kit 1200KTG9075 Filter Head C "For more information go to www.filirite.com _19 19 21 20 12 25 \ o 10 TUTHILL 6825Aviation Drive n Transfer Systems Fort Wayne. lntliana USA 46609 I Tel 260 70-7524 Fax 260 747-315£ e VA"uthill.com Date of Manufacture (Week -Year) 2 520OG9447 Rev. 1 Goodyear® Engineered Products :: Product Detail Printer Friendly Page Flexsteel® Hardwall APPLICATION: Flexsteel® Hardwall is for dispensing pump applications that require a hardwall construction for full flow and no internal spring guards. The wire -braid construction provides excellent kink resistance, low computer creep, and long service life. UL 330 and CUL approved. CONSTRUCTION: TUBE: Nitrile synthetic rubber (ORS) COVER: Black, Green, Red, Blue, or Yellow Chemivic® synthetic rubber (ORS) REINFORCEMENT: Wire Braid TEMPERATURE: -40°F to 140°F (-40°C to 60°C) PACKAGING: 5/8" and 3/4" Reels or coupled lengths, 10 pieces per box / 1" Reels or coupled lengths, 5 pieces per box BRANDING: Continuous brand "GoodyearTm 559N, Made in USA. 3/4" (19 mm) UL, CUL. Listed Flexsteel Hardwall Gasoline Hose." COUPLINGS: Contact fitting manufacturer for proper fitting recommendation and coupling procedure. NON-STOCK/SIZES: Refer to page 300 for special production run minimum requirements. ORDER CODES:53( 2-327- black X532-331 (green) / 532-332 (red) / 532-333 (blue) / 532-335 (yellow) http://www.goodyearep.com/ProductsDetailPrinterFriendly.aspx?id=2732 Page 1 of 1 8/20/2009 ID NOM. OD I WEIGHT F in mm in. mm. R Ib./ft kg /m. ti 5/8 c 15.9 t 1.00 25.4 0.38 i 0.57 N � 3/4 d 19.1 1.13 28.7 0.44 0.65 1 1 25.41. 38 c 35.1 v 0.57 0.85 N http://www.goodyearep.com/ProductsDetailPrinterFriendly.aspx?id=2732 Page 1 of 1 8/20/2009 BAKER INDUSTRIES NORTHWEST, INC. 12428 Highway 99 South, Unit 56 - Everett, WA 98204-5502 Phone (425) 745-6930 - FAX (425) 353-6788 www. bakerindustriesnorth west. com e-mail: larry@bakerindnw.com #700 SERIES Ground Level Spill Containment — The 700 SERIES GROUND LEVEL SPILL CONTAINMENT units are designed for ground level filling of large Aboveground Tanks. Unique design details and BAKER attention to quality provide for ease of installation and long term reliability. DESIGN FEATURES: ♦ 20 Gallon Spill Containment Capacity. ♦ All Welded Steel Construction. Spill Containment Box -16 GA. Steel. ♦ Continuously Sloped Bottom to Sump for Complete Pumpout or Drain. ♦ Lockable Hinged Access Door with Records Storage Slot. ♦ Packaged in a Fitted Cardboard Shipping Box, Sized to Allow Economical Ground Delivery Anywhere in the Lower 48 States. OPENINGS: ♦ Pipe Connection Choices of MPT, FPT, or Flexible Buna-N Boot Adapter in 2', 3", and 4" Sizes. Fuel and Corrosion Resistant Powdercoat Epoxy, Exterior and Interior. OPTIONS: ♦ Vapor Recovery Pipe Connections of MPT, FPT, or Flexible Buna-N Boot Adapter in 20, 3°, and 4° Sizes. ♦ Larger, Multiple Tank Spill Containment Units Available. UL LISTED I lPEI #700 Series DESCRIPTION MODEL FILL CAPACITY 700-2 _ 2°MPT 20 Gallon 700-3 3"MPT 20 Gallon 700-4 4°MPT 20 Gallon 750-2 2"FPT 20 Gallon 750-3 30FPT 20 Gallon 750-4 4°FPT 20 Gallon 770-2 2'Weather Boot* 20 Gallon 770-3 3'Weather Boots 20 Gallon 770-4 4°Weather Boot* 20 Gallon -Burl:,44 DISTRIBUTED BY: (over) 3/01 Tank Optional'secondaryopeinlh_ V-3'pipesite typically (or;vapar recovery connection .a`FpFfar- " . manlual pump out', —�. 3/8'=16 x 1'stdd fof'- ' i g• ,gtatnd connection 914"' - �-Ccck Tab; •:26Yi' . t r .. A r - I Rft_rds F1 to ��, � C6nUnuousiy slopod bottom to 3' Sump; with WEPT draln a ptug ' 3° (fir t� • i4• '' +� �, b MODEL _ FILL CAPACITY 700-'2B ' - Z P 20,Ga on "700-3B - - AAP - 20Gallons 700-4B I I' Poor in dzk oEk W4 750-2B .a`FpFfar- " . manlual pump out', —�. 3/8'=16 x 1'stdd fof'- ' i g• ,gtatnd connection 914"' - �-Ccck Tab; •:26Yi' . t r .. A r - I Rft_rds F1 to ��, � C6nUnuousiy slopod bottom to 3' Sump; with WEPT draln a ptug ' 3° (fir t� • i4• '' +� �, b MODEL _ FILL CAPACITY 700-'2B ' - Z P 20,Ga on "700-3B - - AAP - 20Gallons 700-4B 40MPT 20Gallons 750-2B 2uFPT 20Gallons '750-3B I 20Ga ons 750-4B I 4"FPT 20 allons 770-2B* rcomp boot 2 Ga. Ions '=770-38 - 3'comp boot 20 A ` n 77 �B Womp boot 20 ns 5"Following any model no. designates stainless steel constrUction. ' "' Cutout and bolt holes pre -:drilled fo't UL Listed ftWbie entry boot (supplied', Yvith unit},., 4GV 71 � ' . typfOi) � sldbs II� To mounting brsWl Wlth 018'dis bolt holo; typ.`5 plcs- #700 SERIES GROUND LEVEL SPILL CONTAINMENT TANK MOUNTING BRACKT MODELS BAKER INDUSTRIES NORTHWEST REV 12428 Highway.99 South, Unit 56 REV Everett, Washington 98204-5502 Tel:(425)212-3169 • FAX:(425)353-6788 • e-mail: Iarry(a).bakerindnw.com REV www.bakerindustriesnorthwest.com MATERIALS: • SPILL CONTAINMENT CABINET: 16GA STEEL MINIMUM (ALT "S" 16GA MINIMUM ' STAINLESS STEEL) • MOUNTING BRACKETS: %" X 2" STEEL FLAT BAR (ALT "S" S/S SCH 40 MIN) • FILL AND DRAIN PIPE FITTINGS: ALL STEEL, SCH 40 MIN (ALT "S" S/S SCH 40 MIN) • LOCK TABS: 3/16" STEEL WITH Y2'DIA PADLOCK HOLE (ALT "S" 3/16" STAINLESS STEEL) • COATING: POWDERCOAT EPDXY FINISH INTERIOR AND EXTERIOR (ALT "S" BARE STAINLESS STEEL, NO COATING) CAUTION FLAMMABLE OR COMBUSTIBLE LIQUIDSIVAPORS MAY BE PRESENT. KEEP AWAY SPARKS, FLAME, IGNITION SOURCES. EXTINGUISH SMOKING MATERIALS. FOR USE WITH PROPERLY VENTED STORAGE VESSELS. KEEP DOOR CLOSED AND LOCKED WHEN NOT IN USE. This drawing and design are proprietary to BAKER INDUSTRIES NORTHWEST, and may not be copied or duplicated in whole or in part without the written permission of BAKER INDUSTRIES NW. DRAWN CHECKED DATE LRG RBW 03-28-95 SLG LRG 03-05-06 Sec. I UL Listed Emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement, to help prevent the tank from becoming over -pressurized and possibly rupturing if ever exposed to fire. Vent must be used in conjunction with a "normal vent." Correct application of this vent requires proper vent size and selection for the tank system in order to meet the specific venting capacity. Morrison Bros emergency vents conform to the following codes and standards: API 2000, International Fire Code, National Fire Code of Canada, NFPA 1, 30, 30A, 31, 37, 110, PEI RP200, PEI RP800, Underwriters Laboratories Inc., UL -142 UL -2085 UL- 2244, Underwriters Laboratories of Canada CAN/ULC S601-07, CAN/ULC S602-07, CAN/ULC S652-08. Additional References: NFPA 30, UL 142, Morrison Venting Guide. I.D. Number A B C D E F G Diameter Height Weight 2440-0600 AV 8 504,818 8 1 A AL 11 4.6 33 2440-0600AVEVR 8 504,818 8 1 B AL 11 4.6 33 2440-0700 AV 8 504,818 16 1 A AL 11 5.8 62 2440-0700AVEVR 8 504,818 16 1 B AL 11 5.8 62 24401-0600 AV 8 504,818 8 1 A 1 11 4.6 39 2440F-0100 AV 8 1 504,8181 F 8 1 I 1 A I AL 11 13.3 33 2440F-0100 AVE 8 504,818 F 8 I 1 B AL 11 3.3 33 2440F-0200 AV 8 504,818 F 16 1 A AL 11 4.5 67 2440F-0200 AVE 8 504,818 F 16 1 B AL 11 4.5 67 2440M-0600 AV 8 504,818 M 8 1 A AL 11 5.8 34 440M=0600AVEVR 08 504,818 QM ®8 © ©B RI 1t 5.8 2440M-0700 AV 8 504,818 1 M 16 I A AL 11 6.9 63 440M=0700AVEVR 6J 504,818 Q 16 M Q AL 11 6.9 63. 2440MB0700 AV 8 504,818 M 16 I A AL 11 6.9 63 2440MBSP0600 AV 8 504,818 M 8 1 11 5.8 34 2440MI0600 AV 8 504,818 M 8I tAll 11 5.8 42 2440MI0700 AV 8 504,818 M 16 1 11 1 6.9 71 Flange = 14" OD; eight (8) .88" Diameter holes on 11.75" diameter B.C. 3 C @US LISTED CHART KEY: A—Size: 8" B—Venting Capacity/CFH (in 1000's) C—Mounting Connection: Female N.P.T. (BLANK); Male N.P.T.(M); Flanged (F); D—Pressure Settings: 8, 16 oz/in2. Pressure Required to Open Vent. E—Cover: Cast Iron Powder Coated (1) F—Seat Material: O -Ring Viton A (A) or Viton B (B) G—Body Material: Aluminum (AL) or Iron (1) Diameter—Dimension Across Vent Height—Dimension From Base to Top When Closed Weight—Shipping Weight Bolt—Zinc plated steel f WARNING: DO NOT FILL OR UNLOAD FUEL FROM A STORAGE TANK UNLESS IT IS CERTAIN THAT THE TANK VENTS WILL OPERATE PROPERLY. Morrison tank vents are designed only for use on shop fabricated atmospheric tanks which have been built and tested in accordance with UL 142, NFPA 30 & 30A, and API 650 and in accordance with all applicable local, state, and federal laws. In normal operation, dust and debris can accumulate in vent openings and block air passages. Certain atmospheric conditions such as a sudden drop in temperature, below freezing temperatures, and freezing rain can cause moisture to enter the vent and freeze which can restrict internal movement of vent mechanisms and block air passages. All storage tank vent air passages must be completely free of restriction and all vent mechanisms must have free movement in order to insure proper operation. Any restriction of airflow can cause excessive pressure or vacuum to build up in the storage tank, which can result in structural damage to the tank, fuel spillage, property damage, fire, injury, and death. Monthly inspection, and immediate inspection during freezing conditions, by someone familiar with the proper operation of storage tank vents, is required to insure venting devices are functioning properly before filling or unloading a tank. LAMorrison Bros. Co. Established 1855 1 t P.O. Box 238 • Dubuque, Iowa 52004-0238 563.583.5701 (tel) • 800.553.4840.563.583.5028 (fax) www.morbros.com V A a HUSKY PRESSURE,/ VACUUM VENT VENT CAP FOR UST Model 5885 has three • The first over -pressure SPECIFYING INFORMATION separate valves that valve is diaphragm address pressure / operated, giving 10 times Model Weight vacuum conditions in more sealing force than Number Description lbs.(kg.) underground storage gravity devices. It opens a tanks (UST). 2.5" - 6" WC pressure. 5885 2" Thread -On Pressure./ 1.2 (.54) Vacuum vent cap with , • The Husky 5885 pressure The safety over -pressure internal screen / vacuum (PN) vent valve is designed to incorporates three ' - handle high pressure / CONSTRUCTION separate valves to control high flow conditions. This over -pressure and vacuum valve will vent up to 7900 Body. Aluminum conditions that arise in SCFH at 2 PSI. storage tanks. This three Screen 40 Mesh Stainless Steel valve system provides the • Certified to less than 1/3 Internal Screen 40 Mesh Stainless Steel necessary protection and of the new CARB EVR durability needed in a UST Standard CP -201 which Set Screws Stainless Steel vent cap. allows installation of 3 . PNvents maximum. This, Deflector Aluminum • The 5885 has an internal reduces installation time screen to protect the by not having to manifold PATENTS and LISTINGS pressure plate in the event the vent pipes together. of a bad bulk drop., Patent Numbers: 5,957,157 • The 5885 is a threaded • The vacuum valve is vent cap that is easily U� diaphragm operated and installed by using the Listings: GARB EVR E.O. VR -101, VR -102, provides 10 times more cast -on hex nut. This also sealing force than gravity allows tightening without VR -103, VR -104, devices. It consistantly having to go between vent VR -105 opens at 6" - 10" of water pipes. column (WC) vacuum. _Rf; Gtsne�o�.pQ00 MADE IN THE U.S.A. This component was tested to and met the following criteria: PRES. 2.5-6 IN. W.C. VAC. 6-10 1N. W.C. .05 CFH @ +2 IN. W.C. .21 CFH @ -4 IN. W.C. Rev. 07-08 u Model 818 Clock Gauge SPECIFICATION SHEET The Morrison Fig. 818 Clock Gauge is used for measuring liquid level in aboveground storage tanks. Readout format is on a standard 12 hour clock face. Small hand represents feet and the large hand inches. Gauge can be read up to 20-30 ft. away to within 1/8". Maximum measurement capability is 12 feet. The gauge can be rotated 3600 after mounting. Vapor tight up to 5 psi. CEVR RT ta ESR YJ' Elft Qawm= I D 10 I a; 0; 4 D I(a'© 1 0 818---0100 AG N M ST S 8.54 3.48 6.06 1 4.5 NPT 818---0100AGEVR Q ©M ST ®S 8.5-4 3.4$: 6.06 4.5 NPT 818---0400 AG N M DT S 8.54 3.48 6.06 4.5 NPT 818 ---N M DT S 8.54 3.48 6.06 4.5 NPT 818F--0100AG N F ST S 9.5 3.48 6.06 4.5 NPT 818F--0100AGEVR N F ST S 9.5 3.48 6.06 4.5 NPT 818F--0400AG N F DT S 9.5 3.48 6.06 4.5 NPT 818F--0400AGEVR N F DT S 9.5 3.48 6.06 4.5 NPT 8181--0000 AG N M NO 1 8.54 3.48 6.06 4 NPT 818MEB0100 AG N M ST M 8.54 3.48 6.06 4.5 BSP 818MEB0400 AG N M DT M 8.54 3.48 6.06 4.5 BSP 818MEF0100 AG N F ST M 9.5 3.48 6.06 4.5 NPT 818MEFOIOOAGEVR N F ST M 9.5 3.48 6.06 4.5 NPT 818MEF0400 AG N F DT M 9.5 3.48 6.06 4.5 NPT 818MEF0400AGEVR N F DT M 9.5 3.48 6.06 4.5 NPT 818METOIOO AG N M ST M 8.54 3.48 6.06 4.5 NPT 818METOIOOAGEVR N M ST M 8.54 3.48 6.06 4.5 NPT 818MET0400 AG N M DT M 8.54 3.48 6.06 4.5 NPT 818MET0400AGEVR N M DT M 8.54 3.48 6.06 4.5 NPT 818T-0100 AG** N M ST S 8.54 3.48 6.06 4.5 NPT 818T-0400 AG" N M DT S 8.54 3.48 6.06 4.5 NPT 818FT-0100 AG`" N F ST S 9.5 3.48 6.06 4.5 NPT 818FT-0400 AG" N F DT S 9.5 3.48 6.06 4.5 NPT 818MEFT400 AG" N F DT M 9.5 3.48 6.06 4.5 NPT 818METT400 AG'" N M DT M 8.54 3.48 6.06 4.5 NPT "Teflon coated, DEF compatible r g' n�'; 3 1 ; i Standard Face Plate Floating Suction Face Plate U MORRISON BROS. CO. 37 5_, Metric Face Plate SPECIFICATION OPTIONS: A -Overfill Alarm: Yes/No B -Body Connection: Male (M), Female (F) C -Float Device: Standard 2" Float (ST), Drop Tube Float (DT), or No Float (NO) D -Face Plate: Standard (S), Metric (M), Floating Suction (1) E -Height in inches (see diagram below) F -Width in inches (see diagram below) G -Clock Diameter: (Inches) H -Shipping Weight: (Lbs) I -Body: Aluminum with 2" NPT or BSP (Metric) Connection Float': Stainless Steel; Cable: Stainless Steel Not to scale 57o E. 7th Street, P.O. Box 238 1 Dubuque, IA 52004-0238 t-563-583-5701 1 800.553.4840 1 f.563.583.5028 www.morbros.com A typical turbine model designation ' has up to five components to define the pump being supplied as follows: STP XXXXX FY,�-W-17 STP.=.Basic Model Designation XXXXX = Factory Installed Options STP model designations may include one or more of the following characters in alphabetical order: AG = Alcohol -gasoline compatible (100% ethanol'or methanol capable) Note: Standard models 0% to 15% ethanol or methanol capable. F = Floating suction adapter (I-1/2" NPTfemale adapter) K = Intake filter screen (IFS, factory installed to PMA) •R = Model R check valve (2 4p si relief/22 psi reset for PLLD) •W = Model W check valve (16 psi relief/ 13 psi reset for PPM4000) 'Note: If not otherwise specified, all 'STP models supplied with standard model check valve (40 psi relief/35 psi reset for MLD and TS-LS300) �Y = Pump MotoR Horsepower Rating 33 = 1/3 hp fixed speed 75 =3/4 hp fixed speed []A = Model Length" VLI = Variable length range #I. VL2 = Variable length range #2. VL3 = Variable length range #3. Note: VL2 models fit 94% of all known installations. [B]=,Riser Pipe Length Riser pipe length is expressed as two numeric characters that indicate the total length of the riser in inches. Riser pipes are available from 7" to 69" in I" increments (additional charge for risers 31" or longer). 1/3 and 3/4 HP Fixed Speed Submersible Turbine Pump Specifications For full diagram see page 5. I Power Requirements • 1/3 and 3/4 hp fixed speed models require single-phase, 208-230 VAC, 60 Hz incoming power. • 1/3 and 3/4 hp fixed speed models incorporate a starting and running capacitor, with internal bleed resistor, rated 370 Volt, 15 microfarad. • STP -SCI single-phase smart controllers and STP -CBS single-phase control boxes are available for 1/3 and 3/4 hp pump control. • 1/3 hp max. motor draw: 4 Amps. • 3/4 hp max. motor draw: 7 Amps. Pump Motor • 1/3 and 3/4 hp fixed speed, 3450 rpm, two-stage centrifugal type pump motor - with integral, automatic, thermal , overload protection. • 1/3 hp models have a max. flow of 40 gpm and a max. pressure of 28 psi. • 3/4 hp models have a max. flow of 65 gpm and a max. pressure of 31 psi. Liquid Compatibility • Max. liquid viscosity: 70 SSU at 60'F (15 °C). • Standard models are UL and cUL listed for fuel mixtures containing up to 15% ethanol or methanol, and 20% MTBE, 20% ETBE or 17% TAME with gasoline. • STPAG models are compatible with fuel mixtures containing up to 100% ethanol or methanol, and 20% MTBE, 20% ETBE or 17% TAME with gasoline. • 1/3 and 3/4 hp fixed speed models can also be used with diesel fuels, fuel oils, kerosene, Avgas and jet fuels in a non -gelled pourable state. • All wetted elastomers are made of a high grade, fluorocarbon Viton®• compound. Standard Features 1/3 and 3/4 hp fixed speed models are available in variable and fixed length options. • Check valve: 2-3/4" diameter fluorocarbon Viton®' seal constructed on cast aluminum body and steel backing washer. • Pressure relief valve: available in four pressure relief settings, integral to check valve. Standard model relieves at 40 psi and resets above 35 psi. • Syphon: venturi-type syphon primer supplied with every submersible. Syphon check valve and secondary syphon sold separately. I ' • Air eliminator: every submersible includes a tank return path with one-way check valve to provide active air elimination. - • Electrical disconnect: electrical yoke for positive contractor disconnect during service. Approvals, • Consult factory for applicable approvals. Quality Certification • Franklin Fueling Systems is an ISO 9001 Certified Manufacturer. 'Viton® is a registered trademark of DuPont Dow Elastomers. C UL US•USTED 19 90 80 70 1/3 HP High Pressure Fixed Speed Turbine Performance Chart F° 30 20 ------------------------------------ --- ------------------- --- --------- '--- 10 ------------------------------------ ----------------------------------` 0 0 20 40 60 Flow in Gallons per Minute (GPM) Note: Performance based on pumping solvent (0.78 specific gravity). Pressure is taken at the manifold discharge outlet. STP33 models are powered by a single-phase, 60 Hz, 208/230 Volt power supply. 3/4 HP Fixed Speed Turbine Performance Chart 90 80 70 3 40 F2 30 80 ---------- -- --•----------------------------------------------------------- Two ---------------------------- ----------- Two STP75 Manifolded 3/4 HP Pumps ---------- --------------------- ----------------- One STP75 3/4 HP Pump ------- ----------- --------- ---------- -------------- ------------------------------- --------------------------------------- --------------------------- 3 ----- -------------- --------------------------------- ------------------------------------------------------------------------ -------------- 20 ---------- ----------------------- ---------- ---------------------�----------- 0 0 20 40 60 80 100 120 Flow in Gallons per Minute (GPM) Note: Performance based on pumping solvent (0.78 specific gravity). Pressure is taken at the manifold discharge outlet. STP75 models are powered by a single-phase, 60 Hz, 208/230 Volt power supply. 20 140 �m Descr pt on 400137908 Syphon check valve, alcohol -gasoline compatible (when ordered with STP) 400818921 1/3 and 3/4 HP Fixed Speed Submersible Turbine Pumps 402312921 U a� 1402312921 STP-DHI-SCI, combo DHI with factory wired STP -SCI when purchased without a 4" STP)' 4023 1 392 1 STP33-VLI 1/3 hp fixed speed VLI 55%83", STP33-VL2 I/3 hp fixed speed VL2 86"-147" STP -SCI, single-phase smart controller (when purchased without a 4" STP) w V STP33-VL3 1/3 hp fixed speed VU 118"-209" ' STP75-VLI _ 3/4 hp fixed speed VLI 57"-86"� STP75-VL2 3/4 hp fixed speed VL2 88"-149" STP75-VL3 3/4 hp fixed speed Description VU 1 120"-212" Model Length* STPAG33-VLI 1/3 hp AG fixed speed 7VL2 SS"-83" STPAG33-VL2 1/3 hp AG fixed speed 86"-147" STPAG33-VL3 1/3 hp AG fixed speed 118"-209" STPAG75-VLI 3/4 hp AG fixed speed VLI S7"-86" (STPAG75_VL2)3/4 hpAG.fixed sp:.' VL2 88"-149" I STPAG75-VL3 3/4 hp AG fixed speed VU 120 -212" j Notes: 1. STP models are compatible with fuel mixtures containing: up to I S% ethanol or methanol with gasoline, and 20% MTBE, 20% ETBE or 17% TAME with gasoline. ' STPAG models are compatible with fuel mixtures containing: up to 100% ethanol or methanol with gasoline, and 20% MTBE, 20% ETBE or 17% TAME with gasoline. 2. All models are supplied with a standard check valve unless factory option "R" or "W" is specified. 3. All above models require single-phase, 208-230 VAC, 60 Hz incoming power. 4.4" riser pipe, if supplied locally, must be 4-1/2" OD by 3/16" WT tubing. S. For riser pipe lengths 31" to 69", adder charge applies. 'Model length (A) defined as the dimension from turbine manifold bottom to pump motor inlet. Factory Installed Options (specified in model number at time of STP order) . • Description /Jf/ F Floating suction adapter, 1-1/2" NPT female, must be factory installed K IFS (intake filter screen), factory assembled to pumppmotorassembly ntl ca R Model R check valve, factory installed, forVeeder-Root PLLD Line Leak W Model W check valve, factory installed, for Red Jacket PPM4000 Line Leak Field Installed Options (1/3 and 3/4 hp fixed speed specific accessories) �m When purchasing STP -SCI or STP-DHI-SCI in equal quantities of fixed speed 4" STPs, the STP -SCI or STP-DHI-SCI will be invoiced at special discount pricing. 21 Descr pt on 400137908 Syphon check valve, alcohol -gasoline compatible (when ordered with STP) 400818921 STP -CBS, single-phase control box with lockout switch, 110 Volt coil 402312921 STP-DHI-SCI, combo DHI with factory_ wired STP -SCI (when purchased with a 4" STP)', 1402312921 STP-DHI-SCI, combo DHI with factory wired STP -SCI when purchased without a 4" STP)' 4023 1 392 1 STP-DHI-CBS, combo DHI with factory wired STP -CBS 1402459931 _ _ Model 65 psi check valve (for slave of manifolded STPs with Veeder-Root PLLD) Secondary syphon kit (when two syphon primes are required for one STP) 402507930 5800100215 STP -SCI, single-phase smart controller (when purchased without a 4" STP) 5800100215 STP -SCI, single-phase smart controller (when purchased with a 4" STP)' 5800300100 STP-DHI, dispenser hook isoes, up 'isolation for I I OVolt dispenser handle switchto eight each When purchasing STP -SCI or STP-DHI-SCI in equal quantities of fixed speed 4" STPs, the STP -SCI or STP-DHI-SCI will be invoiced at special discount pricing. 21 Mechanical Line Leak Detector For use with 4" STPs, the MLD product line is precision built, with unique construction features that provide busy stations with maximum flow rates and long service life. The MLD is offered in three models to match your exact application, ensuring accurate, nuisance -free operation critical to profitable station operation. BRASS PISTON THERMAL CON COMPENSATIO Specifications: • Three models: STP -MLD (blue) for gasoline, STP -MLD -D (tan) for diesel and STP -MLD -E (grey) for some expandable pipe applications. • Solid brass piston has 1-5/8" of travel to move the leak detection poppet fully out of the flow, offering minimum flow restriction and maximum flow rates. • Burnished brass cylinder liner and polished stainless steel piston rod ensure smooth operation and long life from the Teflon seal. • Thermal compensation chamber of 5-3/4 cubic inches helps minimize thermal contraction nuisance tripping. Liquid Compatibility • Max. liquid viscosity: 70 SSU at 60 °F (15 °C). • STP -MLD and STP -MLD -E models are compatible with fuel mixtures containing up to 100% ethanol or methanol, and 20% MTBE, 20% ETBE or 17% TAME with gasoline, as well as diesel fuels, fuel oils, kerosene, Avgas and jet fuels. • STP -MLD -D models are listed for diesel fuels or kerosene only. 24 BURNISHED BRASS CYLINDER LINER TEFLON SEAL TEFLON SEAL GROUND AND POLISHED STAINLESS STEEL PISTON ROD Approvals • Third party certified to comply with US EPA requirements 280.41 (B) and 280.44 (A) for continuous monitoring of pressurized piping. • Consult factory for other applicable approvals. Quality Certification • Franklin Fueling Systems is an ISO 9001 Certified Manufacturer. • All models are capable of detecting line leaks equivalent to 3 gph at 10 psi when installed properly with the appropriate fuels. All models will signal detection of leaks by restricting product delivery to less than 3 gpm and taking more than 4 seconds to open. • All models require 2 to 3 seconds to make a line test when no line leaks exist and air is purged from piping between the discharge of the MLD 4and the dispenser solenoid. ZZ • All models will remain in the "open" , Rl position during product delivery to manifold, with discharge pressures as low as I psi. All models will reset to F the "tripped" when line pressure delay is below 3 psi with pump off. • All models will detect leaks up to 10 feet above the MLD installation point. C (9USLISTED 'Mechanical Line. Leak Detector t i' ;(for use with 4" STPs)' Q Single Pack r Part Number Description (400500901) (STP_MLD,for"gasoline, blue] 1400501901 STP -MLD -D for diesel or kerosene, tan 400502901" STP -MLD -E for expandable piping, grey , Three Pack t1 � EME== Description 400500903 STP -MLD for gasoline 400501903 STP -MLD -D for diesel or kerosene _ 400502903" STP -MLD -E for expandable piping 400503903 COMBO, contains two STP-MLDs and one STP -MLD -D Notes: I. MLD and MLD -E models are compatible with fuel mixtures containing up to 100% ethanol or methanol with gasoline, a diesel fuels, and 20% MTBE, 20% ETBE or 17% TAME with gasoline., f 2. MLD -D models are listed for compatibility with diesel fuels and kerosene applications only. f 3. All above models will only mount in the 2" NPT leak detector port of a 4" submersible turbine, including competitive models, or in a leak detector adapter tee (sold separately below). t I Designed for limited flexible piping systems with low bulk modulus, consult factory before ordering. i "Refer to STP -MLD installation manual for complete compatibility specifications. MLD Repair Parts and Accessories - }' CMEE= Description 4; 1, 400440101 MLD vent tube ; 400449901. MLD hardware pack, fittings and documentation (400518001 Leak detector adapter tee) ,if - •3.50" t MLD - 12.50" 10.65" MLDVENTTUBE SYPHON PORT a LEAK DETECTOR PORT 2" NPT ' TANK PORT x (VENTTUBE MUST BE i' CONNECTED HERE) r i' l r ,t 25 Full Port Stainless Steel Features and Specifications: ♦ Sizes available -see chart ♦ Full port for minimum pressure drop ♦ Stainless steel body and ball ♦ Blowout -proof stainless steel stem ♦ Stainless steel lockable handle with PVC grip ♦ Teflon' packing ♦ Teflon® seat ♦ Teflon' seals ♦ Threads NPT ANSI B.1.20.1 ♦ Temperature range from -20°F to +350°F ♦ 1000 PSI non -shock, cold working pres- sure ♦ Lock device accepts #3 Master padlock ♦ Mounting pad for easy automation T Fig. 691 BSS Full Port Locking Ball Valve Size Part Number ''/z° 691 BSS03001 V 3/4' 691 BSS04001 V 1" 691 BSS05001 V ,, Weight .70 1.16 (2) (691 BSS08001 V� which is in pounds. aREIP 3" 691 BSS10001 V SIZE '/z" 3/E' 1" 1'/z" tT) 1 3" Dimension A 2.44 2.80 3.27 4.04 4.92 6.85 Dimension B 2.24 2.70 2.85 3.74 4.11 5.16 Dimenson C 3.78 4.96 4.96 7.01 7.01 9.61 Port Size .63 .79 .98 1.50 2.01 3.15 Weight .70 1.16 1.62 3.38 6.11 19.60 NOTE: All dimensions are in inches, except weight MEM.C. which is in pounds. aREIP Morrison Bros. o �hu.tw.xnC.s P0. Box 238 • Dubuque, Iowa 52004-0238 V . Ur 563.583.5701 (tel) • 800.553.4840.563.583.5028 (fax) Established 1855 www . m o r b r o s. c o m Description — FLEX-ING's premiere above and below ground fire rated flex connector. I- ,s•. ss• Application — Connects the shear valve with piping in - dispenser- Features — • Successful Praxair/Tracer Testing • All metal construction means one flex -connector for both above and below ground applications. Testable under full vacuum. • UL Listed for above and below ground installation. • An 18-8 alloy with titanium, 321 Stainless Steel inner core provides a long service life. • Standard wall thickness with close pitch corrugations gives more flexibility. • The 346 Integral Male Swivel" ensures ease of installation with a multi -seal design. • Thick, schedule 80 hex end fittings protect against deformation • of the ends. 100% pressure tested to assure quality. • 350 psi working pressure assembly exceeds UL 50 psi • requirement on 3/4" - 3". 225 psi on 4" Minimum Bend Radius from Centerline of Hose 6" - Hose up to 2" 9" - Hose up to 3" 13" - Hose up to 4" NFPX MEMBER 2009-2010 See Requirements and Installation Instructions on Page 2 U� Requirements — • Must be used in a liquid tight sump • Must be used with operational leak detection • Must not come in contact with Brine, Saltwater, Saltwater splash, saltwater spray and/or chlorine • You must visually inspect the flex connector for any defect or damage that may have occurred during shipping • If you find a damaged flex connector, you must return it to FLEX-ING or the authorized distributor • Flex connectors must be replaced when the dispenser has been hit or disrupted • Replace the flex connector if the shear valve has broken. Shear valve must remain properly mounted • Tags are an integral part of the connector and must remain intact • Do not remove tags or labels • Never coat a flex connector with a non -approved coating • Do Not torque flex connector • Install in one plane of motion • Do Not exceed minimum bend radius • Do Not compress or deform • You must be OSHA trained and have OSHA approved equipment Installation Instructions — DO NOT COMPRESS OR EXTEND AXIALLY Corrugated metal hose installed in-line with the longitudinal axis of the piping should not be subject to axial movement. corrm Wron PROVIDE SUPPORT When installing the assembly in a horizontal loop, provide support for the arms to prevent the hose from sagging. correct Wrong , swolrq «w i ' WJ AVOID SHARP BENDS Use elbows to avoid sharp bends near the end of the metal hose assembly. DO NOT ALLOW MOVEMENT IN MULTIPLE PLANES Flexing a metal hose in two separate planes of movement will torque the hose assembly. Always install the metal hose assembly so that flexing occurs in one plane only, the plane in which bending occurs. I f I I Flex connectors must be used in a liquid tight sump with operational leak detection. co p I.cc. In Pyne Ilexlnp o..IoT Plens flexlnp MAINTAIN MINIMUM CENTERLINE BEND RADIUS Flex connectors must be used in a liquid tight sump with operational leak detection. W" t ` correct DO NOT TORQUE DURING INSTALLATION Do not use to compensate for bolt hole misalign- ment Floating flanges will help to minimize twisting of the metal hose. Pipe unions will help to reduce twisting during connection to the piping. The use of two wrenches will help to keep the hose from twisting when tightening the pipe union. �xj ry Correct Wrong In plane out of plane flexing flexing Installation Instruction Tags are an integral part of the flex connector. If you receive a Flex -connector without an installation tag contact us immediately at 1-800-333-3599. Removal of this tag voids the warranty and the LIL Listing. All metal hose assemblies are custom made. We do have standard catalog products but they are considered non -stock. All returns require a Return Goods Authorization number and a re -stocking charge will be applied. Some products may be non -returnable. r p 2828 FALLON DR SHERMAN, TX- 75090 • SIZE PART # DRAWING NAME - A FF20XIBM346XF_ 2' M346 X 2' FEMALE X 18' ❑AL DRAVING BY, DATE .SHEET BRANDON THOMPS❑N 3/6/09 V' 1 OF 1 q i 1 } The Fig 710 Solenoid Valve is a two-way, one directional flow, hung piston valve that is normally closed in the "at rest' position. The valve opens upon receipt of an electronic signal such as when a dispenser or pump is switched on. CSA certified. Available in forged bronze or stainless steel. • Operates at 120 volts (240 volts available). • Includes a continuous duty Class H standard coil. Other options are available. • Must be mounted with solenoid vertical and upright. • No differential pressure is required to open the valve. • Connects to a 1/2" conduit. • Enclosure is watertight and rated for hazardous locations - NEMA 3, 4, 7 and 9; groups C and D. • Available in Viton or Teflon seals. (3" Viton only) • A strainer with a 100 mesh screen is recommended at the inlet. • Has a built-in expansion relief. • Maximum viscosity rating of 60 Centistokes. NOTICE: It is strongly recommended that aline strainer be installed at the inlet of this valve. Failure to do so may cause the valve to malfunction and void the warranty. WARNING: Valve will not function with liquids having a viscosity greater than 60 centistokes. WARNING: Valve will not function on the suction side of positive displacement pumps. Fig. 710 Technical Data The water flow vs. the pressure drop for each of the three sizes of the Fig 710 solenoid valve is shown in the following graph. I I.D NUMBER SIZE SEAL ORIFICE CV OPERATING Water Flow vs. Pressure Drop P 40 Solenoid Valves r TEMP. COMSUMPTION Fig. No. 710 e 36 DIFFERENTIAL s 28 1.5" j U 24 --- 2" rM 3" e 20 D 16 7 0 105 r 12 4 5.9 1.5 4.38 o p 8 P 4 S 0 — —�—i 1 10 15 20 25 35 50 75 100 150 200 300 400 500 Fig. 710 Technical Data The water flow vs. the pressure drop for each of the three sizes of the Fig 710 solenoid valve is shown in the following graph. I I.D NUMBER SIZE SEAL ORIFICE CV OPERATING FLUID POWER SHIP GEN. (NPT) MATERIAL SIZE PRESSURE TEMP. COMSUMPTION WT. DIMENSIONS (INCH) DIFFERENTIAL (MAX) (WATT) (LBS.) (INCH) MAX.(P.S.I.) (DEG. F.) MIN. MAX. A B C D 710-00751V .75" VITON .75 7 0 105 180 30 9.25 4 5.9 1.5 4.38 I �r� I �„P.O. Box 238 • Dubuque, Iowa 52004-0238 ------ --- - ---- -- --- - Co. 563.583.5701 (tel) • 800.553.4840.563.583.5028 (fax) Established 1855 www.morbros.com 111SOURCE All Central Vacuum Source installations require the use of the Healy :1 Monitor Assembly. Part Number Central Vacuum Systems are not available for sale into new sites in California. Description l 9000-02 9000 Mini -Jet, Non-elec_ tric, with Syphon Port. One•Mini Jet can handle eight fueling positions with four nozzles in simultaneous full flow. t 912A 9000 Mini -Jet Check Valve Strainer Assembly 940 Regulator Only 940A Vacuum Regulator Upgrade Kit - - "V +. 20 , 9000 Series Mini -Jet Central Vacuum Pump The popular, non -electric Mini -Jet offers the ultimate in versatility utilizing an existing STP's product flow to create vacuum for vapor recovery. One Mini -Jet can handle eight fueling positions with four. nozzles in simultaneous full flow operation. Additional Mini -Jets can be added for larger sites. Provides high reliability and,low maintenance: High vacuum level assures clearing of flooded vapor hoses. • No electrical hook-up " ` • No moving parts creating vacuum •Installs in standard existing STP tank sump CARB Certified for Use With Executive Order Number 600 Bootless Nozzle G-70-165 UST t �Healy 4 Heal 1400 ORVR Booted Nozzle G-70-186 UST K Healy 400 ORVR_Booted.Nozzle ` T G 70 18T AST • 9466 Check 9000 MiM-ftt We O �J, _ • -a lmtJne ' . t Vac Switch 2•Pluq BNI • Syphm Ched Valve Valve —leak Detect. i• Tee H• ang Healy- ' Wedud pen —0411 VeNe I I V4- Bypass Contletnate - t Op., V4pw 111SOURCE All Central Vacuum Source installations require the use of the Healy :1 Monitor Assembly. Part Number Central Vacuum Systems are not available for sale into new sites in California. Description l 9000-02 9000 Mini -Jet, Non-elec_ tric, with Syphon Port. One•Mini Jet can handle eight fueling positions with four nozzles in simultaneous full flow. t 912A 9000 Mini -Jet Check Valve Strainer Assembly 940 Regulator Only 940A Vacuum Regulator Upgrade Kit - - "V +. 20 , 9000-01 MINI -JET INSTALLATION WITH FE PETRO PUMP FIONAL) P TUBE IS USED, QTY. OF FOUR ES ARE REQUIRED Below is a list of required items in a typical 9000-01 Mini -Jet sump installation. 1. 9000-01 Mini -Jet, Healy Systems Central Vacuum Source 2. '/4" Tank Test Port, FE Petro 3. Syphon Valve, FE Petro 4. 2" Pipe Plug 5. Back Pressure Check Valve #9466, Healy Systems 6. Pressure Switch #93928 or 9800-1, Healy Systems 7. W.C. Vacuum Gage, 0" to 100" (FOR TESTING ONLY) 8. '/4" TEE for vacuum gage test port 9. 1" Ball Valve, U L listed 10. '/4" Ball Valve, U L listed 11. F. E. Petro Leak Detector SYSTEMS, INC. 17 Hampshire Drive - Hudson, New Hampshire 03051 Tel: (603) 8822472 Fax: (603) 882-5189 JW -C: I WORDIMYDOCUMENTS19000-208/.i lN8 r6280A a'For use with Central \ Required when station's monthly throt rPart Number Description ' 6280,Vapor Recovery Monitoring System ,. Monitor Assembly (Includes One Each: 6280 Systei gox,•9800 1•Pressure Switch, HPV1.5.Pressure Vent Valve,, • �_ W-4 Control Box STP -Sensing Relay, for Product Input Continuously monitors' system performance in accordance with CARB specifications. Vent Sensor Assembly 1' 62755 For use with Healy Central Vacuum Vapor Recovery Systems only. Required per CARB Executive Order Monitor Only for all USTs and when monthly throughput is greater than 10,000 gallons on ASTs. Control Box Power Supp VDC, 1.5 A t 628028 Printer Paper Roll 628029 Printer Ribbon Cartridge 6299 Intrinsically Safe Module (Optional), for use with Dire 9466 Back Pressure Condensate Drain Check Valy Pressure Switch (replaces 93928 P re Switch) 9800-1 CB1A Control Box Relay with et Kit HPV1.5 9 � t SMCB Control Box Only, with Healy 1005W Solid State Relay +,B 1 WN - fir•; CARIB Certified for Use With Executive Order 9000 Series Mini -Jet with 600 Series Bootless Nozzle G-70-165 UST VP500 Series Vane Pump G-70-165 UST a 9000 Series Mini -Jet with 400 ORVR Nozzle G-70-186 UST VP500 Series Vane Pump G-70-187 AST r6280A a'For use with Central \ Required when station's monthly throt rPart Number Description 6280A Monitor Assembly (Includes One Each: 6280 Systei gox,•9800 1•Pressure Switch, HPV1.5.Pressure Vent Valve,, • �_ W-4 Control Box STP -Sensing Relay, for Product Input n 6275 ' Vent Sensor Assembly 1' 62755 Ven sor. Assembly Pressure Switch for 6280A ' 6280 Monitor Only 628021 Control Box Power Supp VDC, 1.5 A t 628028 Printer Paper Roll 628029 Printer Ribbon Cartridge 6299 Intrinsically Safe Module (Optional), for use with Dire 9466 Back Pressure Condensate Drain Check Valy Pressure Switch (replaces 93928 P re Switch) 9800-1 CB1A Control Box Relay with et Kit HPV1.5 Pressure Ven e, +1.5" WC Pressure HPW Va Vent Valve, +3" WC Pressure, -8" Vacuum SMCB Control Box Only, with Healy 1005W Solid State Relay +,B 1 Control Box Only, without Healy 1005W Solid State Relay I Low Voltage Cable 23 2302A u e Kit, 1-0-1" Water Column Magnehelic 6059 Spout Adapter, it Ratio Test (for use with 600 Series Nozzle Only) 8034 1 LSurrogat t Adapter, Air/Liquid (A/L) Ratio Test 800/ ozzles Only) 8175 ogate Spout Assembly 8175-1 sembly including 8034-1 Clean Air Separator Test Port Assembly 939349A Gage_Kit,.0500" Water Column Z076 Pf9QtLUgjer Package, 600 Series Nozzle, Includes One Each: Dresser Roots Vapor Reco'y Reducer, 6.0' x ries Nozzle Spout A 4 ose R Series Nozzle, Includes One ac or NPT Reducer, 6.0'x 3/4" Tygon Hose, 800 ORVR Series Nozzle Spout Adapter, Two 1/2 NPT 24 x Meter, Flange Kit, 1.5 NPT x 1/2 Model 5z9 & 53o Series Nipple Check Valve U 1''�„ `,,L! - r .SPECIFICATIQN SHEET. , I One-way check valve used to prevent backflow. t: Features 51Z 9 • 'Expansion relief activates below 15 PSI +'k • 529R does not have expansion relief. ► 530 • Expansion relief settings activate at precise. settings 529 fh • Used to maintain accurate line pressure in leak detection systems D! 0 ( 0 t© Q BR BR BR 1.50 529---0100 AV=-N 529R-0100 AV BR BR BR, 1.50 530 530---0100 AV 2®" Yes BR SS BR 1.50 � 530-0300 AV 2- Yes BR SS BR 1.50 { 1 � rr SPECIFICATION OPTIONS: NOTE A—Thread size 529,is not intended for use with leak B—Expansion Relief C—Body: Brass (BR) detection systems due to range of. ,. 1 D—Spring: Stainless Steel (SS), Brass (BR) pressure relief. + ;. E—Poppet: Brass (BR) F—O-ring:.Viton (VI) ' .. ..4. .... .... `.. � i ",i �,, lf4• �! I ,. ��, iii yr. 57o E. 7th Street, P.O. Box 238 Dubuque, IA 52004-0238 t. 563.583.5701 800.553.4840 1 f. 563.583.5028 MORRISON BROS. CO. www.morbr0s.c0m • r • A name you can trust. tri O MNRik, FIRE P ISO EN 9001:2000 /t\ G Foodlndustry NSF61-6 3B'-3/4" Architect/Engineer approval Job Name Date Model Specified Quantity Variations Specified Customer/Wholesaler Contractor Architect Note: Information subject to change without notice. emarJomar International Ltd. vhf 7243 Miller Drive A name you can trust. Warren, MI 48092 Phone: 800-325-5690 Fax: 800-628-4194 www.jomar.com System-& Super Ball- Valve Description System 6® SuperBall'" - 1/4 turn, lever operated, hot forged brass ball valve. 100% full port. Blow-out proof two-piece design. Made in Italy. 100% tested. Features • 2 Viton®Stem Q -rings • Hostaflon® TFM-1600 Packing and Seats • Ecological washed • Solid TEA coated brass ball • 100% Full Port Approvals • UL Listed VQGU, MHKZ, YQNZ, YRBX, YRPV, YSDT, UL 842 • FM approval • CSA Certified • Delta C • NSF 61-8 Certified (1/4" - 2") - tested at 180° F (commercial hot water) • NPT connections Accessories • "Lift -N -Lock" locking device • 2" Handle extension • Lever and Round 304 stainless steel handles • "Slo-Ball" Handle (for metering under high pressures) • Red Painted Aluminum "T" Handle • Pneumatic & Electric Actuation Available upon request Warranty The Company, for a period of one year from the date of shipment, warrants each product or system of its own manufacture to the original purchaser to be free from defects in material and workmanship under normal use, service and maintenance. © Copyright 2006 Printed in U.S.A. T/S-100NE 04/06 System -601. 31 Super Ball- Valve r . • r • A name you can tri Description Material Specifications System 6® SuperBall" - 1/4 turn, lever operated, hot No. Part Name Materials • ' forged brass ball valve. 100% full port. Blow-out proof 1 Body Ecologically Washed Forged Brass two-piece design. Made in Italy. 100% tested. 2 End Adapter Ecologically Washed Forged Brass 3 Ball Solid TEA Coated Brass Ball r _ 4 Seat j2► Hostaflon®-TFM 1600 . Dimensions in Inches 5 Stem Extruded Brass 6 Stem Packing Hostaflon&-TFM 1600b' Computer Valve 7 Stem 0 -Rin s j2j . Vitons No. Size A B C D E CVt g' 100-701 1/4" 1.81 0.91 1.41 0.39 2.95 11.84 8 Gland Follower Extruded Brass ; 100-702 3/8" 1.85 0.93 1.41 0.39 2.95 11.84 9 Lever Handle Dacromet Coated Steel 100-703 1/2" 2.48 1.24 1.53 0.59 2.95 20.25 10 Handle Nut Dacromet Coated Steel .100-704 3/4" 2.71.. 1.36 1.93 0.79 3.74. 41.83 Viton is a registered trademark of DuPont Company Hostaflon is a registered trademark of Hoechst AG Frankfurt 1 D_ 0 705j IJ f3 3J � � " 7 - - - 1 , 100-706 , _ 1-1/4" 3.78 1.89 2.59 '1.25 4.72 132.10 C • ' ' ' 100-707 1-1/2" 4.17 2.09 3.22 1.57. 5.90 206.96 Pressure Rating 100-708 2" 5.00 2.50 3.50 2.00 . 5.90 346.00 1/4"-3/4" 600 lbs. W.O.G. Non Shock 100-709 _ 2-1/2" 6.06 3.03 4.72 2.48 2.50 484.39 1"- 2" 500 lbs. W.O.G. Non Shock 100-710 3" 7.08 3.54 5.31 2.99 3.00 638.50 2-1/2" - 4" 400 lbs. W.O.G. Non Shock 100-711 4" 8.66 4.33 '5.90 3.93 4.00 1092.00All Sizes: 150 WSP t The CV Factor is the gallons of water per minute passed through the valve with a 1 PSI pressure drop. 10 ' ,p76•�SaA�+F�'9 F E C - 6 �.A; B- Valve Seat Rating - O 900 • ' - - Hostaflon--TFM 160( 700 M 500000300 200 ,w O 100 1 0 }{ -20° 32^ 75• 122° 212° 302° 366° _ I•. I^r Temperature IF O WARNING: T/S-100-NE valves are designed for temperatures up to i 366-F, utilizing low presure steam at 150 WSP MAXIMUM O r Note: Information subject to change without notice. Jomar International Ltd. earVJ) ©Copyright 2006 Printed in U.S.A. r/ 7243 Miller Drive T/S•100NE Anameyoucant�st. Warren, MI 48092 04/06 'Phone: 800-325-5690 Fax: 800-628-4194 www.jomar.com ce° G6200 I ICA IIIAAIII I MY JURC, in -a -01 DOM_ i IF -1 JOM-t i IDispenser r F7 -,g: Dresser Wayne Reliance G6200 Series ,Mechanical Fleet Dispensers ; Fueling capabilities you -can -depend on down the road Keeping your fleet on the move depends on reliable', fast access to fuel. Time spent waiting for an available dispenser or struggling with -slow or inefficient fueling equipment can negatively impact your productivity. And any downtime caused by maintenance or repair issues not only increases inefficiencies, it raises your Total'Cost of Ownership. ` Dresser Wayne delivers fueling equipment you can count on to deliver consistent performance today and tomorrow. We've'built the Reliance G6200 Series Mechanical Fleet Dispenser -for reliability and durability, by combining time -proven components with a durable cabinet. It'stands up to years of rugged use in the harshest conditions. .'Superior performance gets vehicles on the road faster Engineered for fast fueling capabilities, the Reliance G6200 dispenser.offers high flow rates up to 22 GPM*. Large capacity inlet/outlet castings, one -inch internal filters and discharge connections provide superior flow performance. The one horsepower motor on suction models offers extra capacity which extends the life of the motor. Plus, the micro=accurate positive displacement two -piston meter is weights arid measures sealable and provides precise measurement at any,flow rate. ` �, Flow rates are maximum test rates at discharge. Actual rates will depend upon application and accessories. e J- K raj tk.� +' B20 BtOD nESEL l Al Q ; TW U Exceptionally adaptable to your needs The Reliance G6200 dispenser gives you flexible configuration choices so you can select a dispenser that matches your needs. The one -inch hose discharge includes a 3/4 -inch adapter allowing all models to be easily adapted to either hose size for standard gasoline or high flow diesel applications. Choose from remote dispenser, suction pump or satellite configurations in addition to a wealth of other options. • High hose masts and internal retractors keep hoses out of fueling lane • Pulsers support connection to popular fuel control systems • Panel lighting enhances register viewing at night • Factory -installed Healy VAC vapor recovery for ORVR and EVR applications • E85 option offers compatibility with ethanol fuel • Stainless steel cabinet lasts in corrosive environments • Lane -oriented nozzle boot conveniently positions nozzle on front bevel Durable construction withstands years of rugged conditions and use We've constructed the Reliance G6200 dispenser using the toughest materials. As a result, it holds up under severe exposure and hard use for many years. The attractive powder -coated finish survives the elements, and cabinet panels and supports are made from corrosion -resistant galvannealed steel. Tough 14 -gauge side panels and 18 -gauge doors make the dispenser ideal for rough fleet environments. Also, the Reliance G6200 dispenser does not require gaskets for weather -sealing which can deteriorate and lose effectiveness over time. r Z . . r s _ y,1 Convenient, simple installation and maintenance simple installation and low maintenance are among the many ways the`Reliance G6200 dispenser improves productivity and reduces. operation costs. A single AC power line feed makes retrofitting to existing installations easy. lts`hinged doors can be removed if necessary by simply pushing abutton for simple access during routine maintenance. The gear -type pumping units (suction models) endure years of,hard use, and the reliable mechanical registers' require little maintenance. Additionally, vertical strainer removal minimizes spills during maintenance, and an adjustable v -link belt in suction models simplifies motor tension adjustment. Ready for tomorrow's fuels, today The Reliance E85" option (E/ model prefix) employs special elastomers, electroless nickel - plating, hard anodizing, stainless steel,'black iron piping and a special ethanol -,compatible filter to - '' provide compatibility with E85 fuel. The E85 option is available for all remote dispenser, models and is also compatible with Standard petroleum products like gasoline and diesel. Dispense E85 today or utilize standard fuels with the peace mind that you are prepared for conversion to alternative fuels in the future. Reliance G6200 Models The Dresser Wayne'G6200 fuel dispenser comes in a wide range of model selections so you can choose the dispenser �} that fits seamlessly within your environment and meets your fleet fueling. requirements. .t 4 1 4} Model Number Format: /Base Model /Suffix 1 Options/ Suffix 2 Options (e.g./G6201P/2GJK/A) t Al non -satellite models include the following options as standard: 1" piping [2), internal fitter [G], AC j -box [J], and hose hanger [K]. Option SUf fes are noted in the specifications 4 - in [ ]: A'W"'(e.g. [//A]) indicates a suffix 2 option. r ->. "Note: "FJ models are.UL L,'sted for ethanol blends up to E85 as well as gasoline anddiesel. . ' Select only hose and nozzle accessories that are expressly compatible with the fuel type being dispensed. Standard features deliver a solid solution Equipped with a rich set of standard features, the Reliance G62OO dispenser offers exceptional value. Based on years of experience and industry leadership, Dresser Wayne incorporates outstanding features into every dispenser. • Internal filters help ensure product purity • All user controls meet American Disability Act requirements • Nozzle boots fit both standard and vapor recovery nozzles • Satellite piping connections are provided for use with satellite dispensers Reliance G6200 Specifications Performance: Up to 22 GPM (83 Ipm) per hose (exception: Twin I suction is 22 GPM per one hose operating, or 12 GPM (45 Ipm) per hose with both operating). Note: Specified rates are maximum test rates at the discharge. Actual /low rates will depend upon the installation conditions, dispenser accessories, and for remote dispensers, size of the submersible pump. Compatibility: For dispensing low viscosity petroleum fuels - diesel; biodiesel blends up to 20%; gasoline, including oxygenated blends; kerosene; AVGasA, and jet fuelA. See E85 option. Fuel must meet the applicable ASTM standard. ANote: Confirm with fuel supplier on any fluid path metal restrictions before use. Install the proper filtration and water separation equipment necessary for aviation fueling. Register: Non -computer mechanical register with power reset with interlock. Displays on both sides of cabinet. Maximum 999.9 gallons. Totalizer: Non-resettable totalizer up to 9999999.9. Displays on front dial face. Meter: Reliable, micro -accurate 2 -piston positive displacement design. Weights & Measures sealable. Pumping Unit++: Positive displacement, self -priming, gear -type pumping unit with integral centrifugal air separator and adjustable bypass valve. Suction strainers at inlet connection. Motor++: 1 -HP continuous duty with thermal overload protection. Adjustable V -link belt connects to pump pulley. Electrical: 115VAC, 60Hz operation. Motors - 115/230VAC 50/60Hz. Internal Filter [G]: Adapter with ten -micron filter helps ensure product purity. Inlet Connection: 11h" NPT (3.8 cm). Discharge: 1" NPT (2.5 cm) with 3/" reducing bushing. Solenoid Valve: 1 " (2.5 cm) two-stage valve. Standard on remote dispensers and Twin I suction. Also provides slow flow control for fuel control systems. With E85 option, valve is single stage. Satellite Connection: Discharge assembly includes 1" NPT (2.5 cm) internal port for satellite piping connection on remote dispensers. Cabinet Finish: Extremely durable powder -coated finish gives outstanding appearance and toughness. Sides, top, bezel, and base painted metallic silver. Doors painted blue (optional black, brown, green, red, silver, yellow, or white). Black register face. Cabinet Construction: All panels are fabricated from heavy gauge galvannealed steel. 14 -gauge side panels and 18 -gauge doors. Top of bezel provides space for product id decals (specify w/ order). Nozzle Boot and Hook: Side location is standard for access from either fueling lane. Fits standard U.L. interchangeable automatic nozzles. Hook may be adjusted for an OPW 11 -VF long spout balanced vapor recovery nozzle. On/off handle for dispenser activation. Optional nozzle boot hood kit for fitting short spout balanced vapor recovery nozzles. Hose Hanger [K]: Keeps hose off the island when not in use. Actual Dimensions: 32.25" W x 19.38" D x 54.38" H (81.9cm W x 49.2cm D x 138.1cm H) Approvals: C -UL -US Listed. Sealable by U.S. Weights & Measures for the resale of fuel with contracted periodic billing of the fuel dispensed. Options, tF!ulsers: Transmit electric Dr-connection.to fuel control and 100:1 [71B] ratio options available. > �Ewfv prefix]: Remote dispensers only ze nickel- ating hard anodizing, lack ironpip �Utik�A_ _ _1? _ _ingj (special _el&stom6F� and a spgcial filter for EQ5-com atibility.-ULListed.lor ethanol blends up_tQE_85_as,.weIl wj_ asolin, Hose Mast Kit+ [//J]: Raises hose tQease hose,lrjaooling and _belp ke _stored, hose_ountt e ane. Optional _oljh fueling j= -hose mast clamp kit+ (p/n 890898-001) for Goodyear® vapor recovery hose. Light [//A]: Illuminates register faces and backlights the translucent product id p6nels that are included . with the light option. One bulb per side. Lane -Oriented, Nozzle Boot [5]: Locates nozzle boot with lift -to -start hook on front bevel. Fits standard UL interchangeable n'o'zzles and Emco Wheaton 4015 and Husky V short spout balance vapor recovery nozzles. Hook extension kits+ for OPW 11 VF (p/n 892081-001) and Healy 400 (p/n 892080-001) long, spout vapor recovery nozzles. Register displays on side of cabinet with applicable nozzle -boot. Stainless Steel Panels: Ideal for very corrosive environments: All exterior, panels [ilS], all panels except painted galvannealed steel doors [//S1], or stainless steel doors only [//S2]. HealyVacVapor Recovery: Remote dispensers only. Factory -installed Healy vapor recovery components for ORVR and EVR applications. One hose [M) or two -hose [D4] options. Does not include hanging hardware.. Electrical Options: 230VAC 50/60 Hz. operation [Z]. For light option @ 50 Hz, also add [//C]. Other Options: Liter measure [8), internal hose retractor [//H], hand crank kit+ [3], reversed accumulative totalizer [//FJ, inlet check valve [;/M],, external filter kit+ (p/n 8899217001), solenoid valves - W1] on suction models, , & short sp6ut vapor, recovery nozzle boot hood kit+ (p/n 892101 -001). N287S and N288S Satellite Specifications Cabinet Finish: Metallic silver sides and top with blue doors (optional black, brown, green, red, silver, yellow, or white doors). Cabinet Construction: Heavy gauge galvannealed steel. Inlet Connection 11/2" NPT (3.8 cm) Solenoid Valve: 11/2" (3.8 cm) two-stage. Electrical: 120VA6, 60 H,. Disclharge: 1 " NPT (2.5 cm) Nozzle Boot Fits UL interchangeable riozzles. Lane -orientation. Lift nozzle.hook to start operation. Hose Hanger [K]: Keeps hose off the island when not in use. Actual Dimensions: 35" W x 20" D x 41.5" H (88.9cm W x 50.8cm D x 105.4cm' H) Approvals: UL Listed. Options: All stainless-steel cabinet [//S], stainless I steel sides and top with paintE;d doors [//S1 ], or stainlesi steel doors only [i/S2]. External filter kit+'(p/n 889921 -001). ++Note:.4ppfies to suction models only +Note: kits require field assembly All remote dispensers include a satellite connection as standard so that they can be piped to an opposing satellite dispenser for the convenient fueling of truck saddle tanks or vehicles positioned with their tank on the opposite side. Reliable VR 101 Non -Computer Register with Power Reset ADA -Compliant On/Off Handle Optional 1 " Two -Stage Solenoid Valve (standard on remote models) Weights & Measures - Sealable Two -Piston Meter Large AC Junction Box (Additional J -Box with Pulser Option) Tough 14 -Gauge Galvannealed Steel _�� Side Panels with Powder Coat Finish Vertical Strainer / Heavy Duty1 HP Continuous Duty Motor }k 0 /G6205P/2GJK Model Optional Light for Lighting Register Face & Product IDs Optional 10:1 or 100:1 VR Pulser (not shown) 1" Satellite Piping Connection (accessible on remote dispenser models) a' 1" Discharge with 3/4"Reducing Bushing Internal 10 -Micron Filter Large Capacity Castings for Connecting Components Dependable Gear Type Pumping Unit with Vortex Air Separator Adjustable V -Link Belt About Dresser Wayne Dresser Wayne, headquartered. in Austin, Texas, .. About Dresser, Inc. fir, -• • is one of the largest business units of Dresser, engineered infrastructure products for the global= r . Inc., and is an industry pioneer for the retail fueling energy industry. The company has leading positions �. ` industry.. Among its innovations, Dresser Wayne actuators, meters, switches, regulators, piping was the first to introduce self-service consoles and _ fuel blending dispensers to service stations, in-. and air and gas handling equipment;. Leading pump card readers and cash acceptors, in -pump brand names within the Dresser portfolio include P' radio frequency identification payment systems ' Y natural gas-fired engines, Masoneilan® control and dispenser:mounted touch screen payment/, .. valves, Mooney® regulators, Consolidated® pressure communication systems. In addition, Dresser meters. It has manufacturing and customer service ' - Wayne designs and markets software systems facilities located strategically worldwide and a , that enable its retail fueling customers to manage www.Dresser.com •t the convenience store.aspects of their businesses more efficiently,- including inventory control, price book management, labor management and site administration. The Dresser Wayne website is www.Dresser,wayne.com. y; I Genuine Parts Protect your warranty, security, and regulatory certifications. .t Insist on Dresser Wayne Genuine Parts for all equipment repairs and upgrades Wayne r www.DresserWayne.com Worldwide Headquarters: )' Austin, Texas, U.S.A. 1+015123888311' ' European Headquarters: ` Malmo; Sweden ti T +46 40 360 500 South American Headquarters: Rio de Janeiro, Brazil ' T. +55 21 2598 7711 E Asia Pacific Headquarters: Shanghai, China T. +21 5899 3976 Fleet Fueling Group Perkasie, Pen nsylvania,'USA T. +01 215 257 1046 R - © 2010 Dresser Wayne. All rights reserved., Dresser, Wayne and Reliance are registered trademarks of Dresser, Inc. f $ 920977 08/2010 .. About Dresser, Inc. fir, -• • Dresser, Inc. is a leader in providing highly • w ' engineered infrastructure products for the global= r . energy industry. The company has leading positions �. ` in a broad portfolio of products including valves; actuators, meters, switches, regulators, piping r' products, natural gas -fueled engines, retail fuel i dispensers and associated point of sale systems ,. and air and gas handling equipment;. Leading brand names within the Dresser portfolio include Dresser Wayne®, retail fueling systems, Waukesha® , natural gas-fired engines, Masoneilan® control ; valves, Mooney® regulators, Consolidated® pressure relief valves, and Roots® blowers and rotary gal`s= meters. It has manufacturing and customer service ' - ,;• facilities located strategically worldwide and a , sales presence in more than 100 countries. www.Dresser.com •t , , •q Wayne www.DresserWayne.com , 4 Hoses and System Accesories 1 2 1 75 Series coaxial hose 2 F2F2 whip hose 3 CX6-W3A non -vapor ready , 5 3 multi -product dispenser hose adapter 6 4 CX6-A non -vapor ready dispenser hose adapter S F3F2 metric -type whip hose 7 6 S41`2 balance -type whip hose 4 8 7 8701W breakaway 8 807 swivel breakaway 75 Series Coaxial Hose Manufactured with a swivel on each end to provide the ease of handling customers prefer. Inverted coaxial design reduces hose size and the steel braided, premium, abuse -resistant outer hose assures long service life and low a maintenance. Available in up to 20' lengths. F2F2 Whip Hose Standard inverted coaxial with fixed, Healy thread hose ends. CX6-W3A Non -Vapor Ready Multi -Product Dispenser Hose Adapter Converts a non -vapor ready high -hose multi -product dispenser to Healy's inverted coaxial hose thread. CX6-A Non -Vapor Ready Dispenser Hose Adapter Converts a non -vapor ready conventional dispenser thread to Healy's inverted coaxial hose thread. F3F2 Metric -Type Whip Hose Adapter -type whip hose allows direct connection to the metric balance hose outlet without the need for a hose adapter. S4F2 Balance -Type Whip Hose Adapter -type whip hose allows direct connection to the balance hose outlet without the need for a hose adapter. 8701 VV Breakaway Full product and vapor shut-off, with 350 lbs. separation force. Spare shear screw allows ease of field repair in the event of a drive -off. 807 Swivel Breakaway Breakaway and nozzle swivel in one. Allows for easier far side fueling. Full product and vapor path shut-off, with 350 lbs. separation force. Spare shear screw allows ease of field repair in the event of a drive -off. is Hoses and System Accessories Standard Healy and Whip Hoses, Hanging Hardware Selection Options with 8701 VV Breakaway and 1301 Flow Limiter COAXIAL HEALY HOSE ADAPTER OUTLET COAXIAL VAPORVAC OR (CX6-A, CX6-W IA, WAYNEVAC METRIC COAXIAL BALANCE -TYPE f y^ CX6-W 2A, CX6.W 3A) M34 DISPENSER OUTLET DISPENSER OUTLET i • 1 O-RING SEALS F2 rim F + 1- F3 I_J I I S4 FITTINGS, S2 I- FITTING S3 FITTINGY'i� FITTING FITTING ^ III F2 FITTING GASOLINE FLOW QUAD SEALS I�--- (� BREAKAWAY. DOUBLE QUAD - RING SEALS FLOW LIMITER (OPTIONAL) u At`r DOUBLE QUAD RING SEALS F' r O-RING SEAL FjS2 FITTING . , S2 FITTING O-RING SEALy"` DOUBLE q p ~ O-RING SEAL�� NOZZLE' 16 75 Series 3/4" Standard Healy Hose Healy straight threaded swivels at nozzle and breakaway ends. J Ar C�� Description 758-030-S2S2 3' standard Healy coaxial hose 7SB-035-S2S2 3-1/2' standard Healy coaxial hose 75B -040-S2 S2 4' standard Healy coaxial hose 756-045-S2S2 4-1/2' standard Heal coaxial hose 756-050-S2S2 5' standard Heal coaxial hos - __ - _ - � 758-055-S2S2 S-1/2' standard Healy coaxial hose �s 75B -060-52S2 6' standard Healy coaxial hose 7513-065-S2S2 6-1/2' standard Healy coaxial hose (758-070-S2S) (T standard Healy coaxial hose; 1 7513-075-S2S2 7-1/2' standard Healy coaxial hose 7SB-080-S2S2 8' standard Healy coaxial hose 758-085-S2S2 8-1/2' standard Healy coaxial hose 7513-090-S2S2 9' standard Healy coaxial hose 75B-095-S2S2 9-1/2' standard Healy coaxial hose 7513-100-S2S2 10' standard Healy coaxial hose 758-105-S2S2 10-1/2' standard Healy coaxial hose 7SB-I 10-S2S2 I I' standard Healy coaxial hose 756-1 15-S2S2 I 1-1/2' standard Healy coaxial hose 758-120-S2S2 12' standard Healy coaxial hose 7513- 1 25-S2S2 12-1/2' standard Healy coaxial hose 7513- 1 30-S2S2 13' standard Healy coaxial hose 758-135-S2S2 13-1/2' standard Healy coaxial hose 756-140-S2S2 14' standard Healy coaxial hose Notes: I. Healy hoses are available from three feet up to 20 feet; contact factory for pricing and availability of lengths not shown. Hoses are CARB-approved for overall assembly lengths up to 20 feet, including breakaway and whip hose. 2. Hoses are supplied in black unless otherwise specified. To order a hose in a color other than black, replace "B" with the code as follows: BL = blue, G = green, R = red. Consult factory for pricing. Adder charge applies for hose colors other than black. - ries 3/4" Standard Whip Hose For use with 87I r away and S2S2 product hose. 75B-008-F2F2 Healy straight thread, fixed ends on br dispenser ends 75B-008-F3F2 Healy straight thread on breakaway end, metric n dispenser end 75B-008-S2F2 Heal t read, fixed end on breakaway end, swivel end on dispense 7SB-008-53 Healy straight thread, fixed end on breakaway end, metric swivel thread end on dispenser 010-S4F2 Fixed end on breakaway end, balance swivel end on dispenser end 1 Notes: I. Hose ends are defined as follows: F2 = fixed ends with Healy straight thread, F3 = fixed ends with metric M-34 thread, S2 = swivel ends with Healy straight thread, S3 = swivel ends with metric M-34 thread, S4 = swivel ends with balance -type thread. 2. Hoses are supplied in black unless otherwise specified. To order a hose in a color other than black, replace "B" with the 1 code as follows: BL = blue, G = green, R = red. Consult factory for pricing. Adder charge applies for hose colors other than black. 1 17 7 t 1 ABOVE GROUND 8c MARINA STEEL DISPENSER CONTAINMENT B-8600 $FRIES EPDXY-COATED, GALVANIZED, STAINLESS OR FIBERGLASS -COATED STEEL Stainless Steel B8600 Structural stabilizer brackets for pressure or suction valves Float amplification reservoir +, Galvannealed & epoxy e powder coated 12 -gauge steel • Mounts dispensers plumbed to above ground tanks • Compatible with mechanical and electronic shutdown devices _� When dispensers are upgraded, the B-8600 remains in place. Switch out only the interchangeable, inexpensive upper dispenser frame Iu aovu atdnadru� (Elevated with`Bravo Float Trip &1 panetration�extending from side.) - B8600 -B Basic - Ships with bracket but no fittings or float cups. -B8600'1'Pf45d6—ct aSliips with one`b�acket; one float cup_and one'1 5 , Z or 3" Flexible fitt ,ing loose. Shear`valves-sej*hate- 000uu rlusn mount Typically inset into dock with side penetration. Flange height is customizable Flush Mount version has same options/models as the Standard. 88600 Series Options: Single Poppet Shear Valve Double Poppet Shear Valve Factory -Installed Penetrations Galvanized coat - B8600 2 Product - Fiberglass coat Ships with two brackets, two float And more! I cups and two 1.5", 2" or 3" Flexible fittings loose. Shear valves separate. a WWW.SBRAVO.COM hVOI I' i 'PROBLEM SOLVED` 800 -AT -BRAVO: r � i made m in USA aaouu-KC I MV Retrofit model B8600 with Bravo Float Trip - B8600 Retrofit 1 Product - Ships with one bracket, one single poppet shear valve, one float cup, one 1.5" nipple, one 3x1.5" reducer and one Electrical Fitting (EBS) - B8600 Retrofit 2 Product - Ships with two brackets, two single poppet shear valves, two float cups, two 1.5" nipples, two 3x1.5" reducers and two Electrical Fittings (EBS) 13A '. Certified,'Co 1Gi�Af�eVVi11/i]iOQJusersrE77fprpnse . %•LIM• �E�?MLBJ�E R 75 Series Coaxial Hose Adapters t-.Ao-Atnose aaapter, non -vapor reaay, oar, Internaaonal only CX6-W3A Hose adapter, non -vapor ready, multi -product units 75 Series Standard and Balance -Ready Healy Hose Breakaways 715W Description Repair kit for 8701 W breakaway, includes valves and O -rings 761 Nozzle end for 8701 W breakaway scuffguard 762 Dispenser end for 8701 W breakaway scuffguard ` 787 Nickel plated brass shear screw for 8701 W 787-1 Nickel plated brass shear screw for 807 swivel breakaway 1795 Clamp repair tool for 8701 W and 807 breakaway 807 Swivereakaway installed between hose and nozzle s 1. - -s-____ .--r— ,$taM—, _hose eakawaywlth vapoY path s�iuC oR5501b�s_tt Ligtfx Z055 O-ring kit for 8701 W with nickel plated shear screw Dispenser Vapor Retrofit Kits* Z044CUniversal for six -hose multi -product dispenser 2046C Universal for four -hose multi -product dispenser Z047C Universal for two -hose multi -product dispenser 'Hose adapters are not included in retrofit kits. Hose Accessories and Spare Parts Description Hose end O-ring for S4 hose end, large I 1301 Hose flow limiter for 8701 W standard breakaway, installed between breakaway and main hose 1302 Hose flow limiter for 807 swivel breakaway, installed between main hose and nozzle t 8103 Hose clamp 1 H13-2 Hose end O-ring, large H13-4 Hose end quad ring 22 HEALY '• ✓ O SLI � ®® • - A . i i a • ,.. , OPTIONAL EQUIPMENT: , •Typical',Suction System Installation, CEBSTfiela'installed) • elect'rical penetrnfion_wlfh seal -fob 3/4° and -1" conduit) • FT float trip assembly for pressurized systems • PS -8600 power shutdown device for suction:systems (13 amp relay and . explosion proof box) • FC -8600 fiberglass coat , • B-27SET-3 ,field installed . vapor penetration for 1-1/2" female NPT with Y'secondary adapter • SV 1-1/2" single poppet product shear valve - •r DV 1-1/2" double poppet product shear valve Typical Pressurized System. Installation . t PRODUCT SPECIFICATIONS: (Mod`el'No;_B'8600=1 P� • B -8600-2P Material: UL listed powder epoxy -coated steel Shipping ' Weight: 140 lbs. . Patent: Patent Pending Depth: 17-1/2" or Custom Length x Width: Lar e: 48"L x 25"W LNlediUTT (36_:t_z 25"W) Small: 29"L x 25"W 10 Plus Series Emergency Shut -Off Valves OPW raised the protection standard in emergency valves when it introduced the first double -poppet valve back in 1989. This industry -changing OPW innovation helped to significantly reduce the risk of fire, explosion, personal injury, property damage and environmental contamination at sites around the world. Major oil companies and jobbers agreed that providing added protection for their customers, investments and the environment were the three most convincing reasons for switching to the innovative new valves. Dimensions in. - cm A 79h6 4_- B 225132 4 C z 21132 4 11 D 2'/16 4 i E 29h6 4ff F 421132 4 I E Materials Top: Cast iron Body: Cast iron 10 PLUS Features ♦ The ONLY emergency shut-off valve in the world designed to protect your customers, investments, and the environment against the potential hazards of undetected shear groove leaks caused by low -impact incidents. ♦ The patent -pending SmadGuardTm design contains shear groove leaks, preventing fuel from leaking into sumps to help reduce the risk of fire, explosion, personal injury, property damage, environmental contamination, product loss and costly clean-up. Ordering Specifications ULUst for up to 85% Etl►anol r ♦ Superior shear groove design and engineering results in reliable valve shut-off in the event of a pull -over or dislodged dispenser. The 10 Plus utilizes the same time -tested field - proven design of the OPW 10 Series Emergency Shut-off Valve — the most specified emergency shut-off valve in the world. ♦ Fusible link releases to automatically close the valve to reduce fire hazard. ♦ Rigorously tested to meet OPW's rigid quality standards. Body Size Body Weight Connection Poppet Mounting Model No. in. cm Ib. kg Threads Configuration Application System 10P-0150 11/2 4 6.7 3.05 NPT Single Pressure Combination 10P-0152 1112 4 6.8 3.10 NPT Double Pressure Combination NEW851'Iz 6.8 83.101 NPT Double Pressure Combination Listings and Certifications CSuS LISTED 10 Plus Replacement Parts Part Number Description 10RPLUS-0150 10 Plus Single Poppet Replacement Top 10RPLUS-0152 10 Plus Double Poppet i Replacement Top 202950 I Tetraseal 200143 i Safety Hub/Fusible Link 10 Plus Series Instruction Sheet Order Number: 201614 OPW 60VS Series Vapor Line Shear Valves OPW 60 Series Vapor.Line Shear Valves are installed on vapor return lines beneath dispensers at grade -level to minimize hazards associated with collision or fire at the dispenser. If the dispenser is pulled over or dislodged by collision, the top of the valve breaks free at the integral shear groove to minimize damage to the dispenser piping. Poppeted models afford additional protection by preventing the release of vapors from the dispenser's internal piping and the vapor line to the tank. The base of the Vapor Line Shear Valve is securely anchored to the concrete dispenser island through a stabilizer bar system within the dispenser sump or pan while the valve top is secured to the dispenser structure to ensure proper - shearing action. OPW Vapor Line Shear Valves are designed to meet the ` requirements of NFPA-30A Section 4-3.7. Poppeted models are UL and CARB- approved. OPW 60VS-1000 "Line Saver" ♦ Shear section breaks on impact to minimize damage to underground Body: cast iron with black piping. Duragard' E -coating 1 Discs: M 19 Viton (DPW 60V3P-f001 OPW 60VP-1001 Poppeted�"1/apor Saver` ♦ Double-poppeted design incorporated to Features _ help prevent vapor loss in the event the dispenser is toppled. ♦ 1" Female Connection to Both Dispenser and Underground Piping. ♦ CARB approved. ♦ Multiple Mounting Methods - Mounting ♦ UL listed. Boss accepts either U -Bolt or Straight Bolt mounting kits. , ♦ 60VSPC-1001 features additional external threads on valve outlet for OPW 60V-1000 "Line Saver" connection to a secondary containment ♦ Shear section breaks on impact to. system. minimize damage to underground piping ONE COMPANY. ONE WORLD. ONE SOURCE." Body: cast iron with black Duragard" E -Coating Discs: M -19 Viton OPW 60VSPC-1001 Features S ♦ 11h" female connection to underground piping. ' ♦ 1" female connection to dispenser piping. ♦ Air -test port to enable vapor line. testing without breaking pipe connections. Ordering Specifications' 2%" r 75mm I - - I 6%" 177mm ♦ Choice of top or side inlet connection. ♦ Three -Point Boss Mount stabilizer bar lower mounting connection; Ll olt upper mounting connection. UL Product # Connections Containment Poppeted Threads 60VS-1000 1" x 1'h" (3 x 4 cm) FNPT (60VSP-1001) 1E�X,1 4,"(3 z 4 cm) FNPTI X 60VSP-101L 1" x 1'h" (3 x 4 cm) FBSPP X 60VSPC-1001 1" x 1'h" (3 x 4 cm) FNPT X X 60VSK-1002 Mounting Kit Includes: (2) Lockwashers, (2) Nuts, (3) Hex Screws, (3) Washers OPW 60V SERIES VAPOR LINE SHEAR .VALVES Materials O P W A DOVBt COMPANY North America Toll Free—TELEPHONE: (800) 422.2525 Fax: (800)421-3297 • Email: domesticsales(aloow-fc.com International — TELEPHONE: (513) 870.3315 or (513) 870.3261 Fax: (513) 870-3157 • Email: inllsales@opw-fc.com • www.opw-fc.com P.O. Box 405003 • Cincinnati, OH 45240-5003.3106 ® © Copyright 2006, OPW Fueling Components i OPW 60VP-1001 Poppeted "Vapor Saver" ♦ Double-poppeted design incorporated to help prevent vapor loss in the event dispenser is toppled. ♦ CARB approved. ♦. UL -listed. & 1 31. 11Zmrn ♦ Duragarde E -Coat Finish - Provides superior corrosion resistance. Ordering Specifications Product # Connections Poppeted 60V-1000 1" x 1" (3 x 3 cm) FNPT 60VP-1001 1" x 1" (3 x 3 cm) FNPT _ X 60VP-101L 1" x 1" (3 k 3 cm) FBSPP X 6OVK-1002 U -Bolt Mounting Kit Includes: (2) V (9.5 mm) u -bolts, (4) washers, (4) nuts 60VK-1003 Straight Bolt Mounting Kit Includes: (4) V (9.5 mm)16 bolts, (4) washers, (4) nuts The 60V Series works with the PISCES" SBK-1200J Only _ REVISIONS -� - REV DESCRIPTION DATE 18" 1.5" SS BRAIDED HOSE 1.5" M346 1.5" MNPT 2828 FA DRIVE o-� FLE)(m'NG �0 N, T SHERMATX 75090 SIZE PART# DESCRIPTION A IFF15Xl8HMXM346 1.5" M346 X 1.5" MNPT X 18" DRAWING BY: DATE PAGE BRANDON THOMPSON 11/29/06 1 OF 1 Enhanced CPU p(ocessor to support m U Otl-tank and multi -application systems. Modular design meets current business and regulatory require- ments, with expansion capabilities for future needs The TLS -350 Plus lets you choose the exact set of compliance and fuel management fea- tures you need today. As regulatory require- ments and your business needs change, the flexible TLS -350 Plus platform allows you to add new features tomorrow. A safe invest- ment. A smart decision. Leading-edge leak detection technology - The TLS -350 Plus has defined the industry standard for tank monitoring systems with: advanced magnetostrictive probe technolo- gies offering 0.2 GPH monthly monitoring and 0.:1 GPH volumetric tank testing; accu- rate, automatic, electronic line leak detec- tion; 4S1TE- advanced technology sensors; and a complete line of standard leak sensors to monitor double-wall tanks, containment sumps, and wet and dry wells. For 24-hour stations and high-volume oper- ations, Continuous Statistical Leak Detection (CSLD), the most advanced leak detection technology available today, provides 24-hour automatic leak detection without tank shut- down. No lost business. No lost operating time. Easy upgrade path from existing TLS -350 �i VEEDER-ROOT { Leading-edge business management features The TLS -350 Plus takes business management a -- step beyond normal fuel inventory management The SiteFax option pro- vides auto -dial fax capa- bility, letting you send up to 16 different reports to 8 separate fax machines on a programmable schedule. The TLS -350 Plus sends alarm messages to your fax instantaneously. The optional fuel manager software, available for the TLS -350 Plus, allows you to track average daily fuel usage, predict the days of remaining inventory, and improve delivery scheduling. System Capabilities • Continuous inventory monitoring • Fast, 0.1 GPH in -tank leak detection for up to 1.2 tanks • CSLD option for continuous 24-hour leak detection • 1_ine leak detection • SiteFax auto -dial fax capability • Ethernet/IP communications • 4S1TE advanced technology sensor compatibility • Interstitial and piping sump leak sensing for up to 64 sensors • Vapor and groundwater monitoring for up to 40 wells • External inputs By utilizing Inform, Veeder-Root's tank management software, all inventory manage- ment and environmental compliance, can be easily centralized on a personal computer in one location. The use of these time and money saving options extend your investment in the TLS - 350 Plus beyond environmental compliance requirements, improving your bottom-line. • Relay outputs • Programmable alarms • Data communications • All third -party tested All proven in the field • Easy upgrade to BIR Emergency Generator Applications • Selectable via programming • One system handles mix of standard and emergency generator tanks • Records generator activity • Complete inventory reports before and after generator operation nteg rated solution for centralized , single system site monitoring. Standard Models Lonso e Firm �uinber. 482_90-0 Descri tion: 9C -3 -50 -Plus Plus nlonuorinR :c)nsole wit ince gra xinter onso e l7onn t gum er: Description: TIS -350 Plus monitoring console without integral printer Console Form Number: 848291.-021. Description: TLS -350 Plus PC version Without printer, keyboard or display TLS -350 Plus Interface Modules The TIS -350 Plus monitoring console contains three compartments in which individual interface modules can be installed. Interface modules may be factory -installed in. the console upon initial ordering, or ordered separately as spare modules to expand an existing system. Form No. Factory Installed Modules Description Feature Compatibility (where applicable) LOW-POWER COMPARTMENT (Limit eight per console, unless otherwise noted) '32'9356,,-002 Four -Input Probe Interface Module Maximum reap Serres 8473 0.1 GPMagnetosinctive P (console. Includes terminal connector for one ground) Series 846.3 0.1 GPH Mag Plus MagnetostrictiveProbe temperature thermistor for the volumetric line leak detector . - 329358y0 Eig tt-Input I(tterstitial iquid Se so _ (Series 7943 Interstitial Sensor for Fiberglass Tanks ar (Interstitial Sensor for Steel Tanks) Series 7943 Piping Sump Sensor) Series 7943 Hy rostatic Sensor) 329357-001 Five -Input Vapor Sensor Interface Module Series 7943 Vapor Sensor 329399-001 Five -Input Groundwater Sensor Module 4SITE Series 7943 Groundwater Sensor 329956-001 Eight -Input Type A Sensor Interface Module 4SITE Series 7943 Discriminating Interstitial Sensor 329950-001 Six -Input Type B Sensor Interface Module 4SITE Series 7943 Discriminating Dispenser 330843-001 Six -Input Pressurized Line Leak Interface Series 8484 Pressurized Line Leak Detection System Module (One per console) Requires TLS -350 Plus version 7.0 or higher software 329356-004 Eight -Input Smart Sensor Module Series 857080 Mag Pan Sump Sensor Series 857280 Vacuum Sensor 332250-001 Seven Input Smart Sensor Module Same as above with Embedded Pressure Sensor HIGH-POWER COMPARTMENT (Limit eight per console, unless otherwise noted) 329359-00J CFour-Relay Output Interlace Module) 329360-001 Two-Input/Two-Relay Output Interface Module 329999-001 Pump Sense Interface Module Accepts up to four inputs 330374-001 Three -Output Pressurized Line Leak Series 8484 Pressurized Line Leak Detection System Controller Interface Module (Two per console) Requires TLS -350 Plus version 7:0 or higher software COMMUNICATIONS COMPARTMENT (Limit three per console, unless otherwise noted) 330149-002 Site Fax Interface Module Allows hookup to most remote facsimile, modem or teletype equipment. Requires TLS -350 Plus version 3.0 or higher software. - 330586 -001 RS -485/232 Dual Port Communications Module (Slot 4 only) 330148-001 RS -232 Interface Module with Auxiliary Port Provides two 25 -pin D -connectors for data transmission to P.O.S. terminal, printing device or computer 329362-001 RS -232 Interface Module Provides a 25 -pin D -connector for data transmission to P.O.S. terminal, printing device, or computer 330000-001 Remote Printer Interface Module Provides a 25 -pin D -connector for data transmission to a remote serial printer 330883-001 WPLLD Communications Module (Maximum one per console) 330020-425 Ethernet —TCP/IP Communications module Provides connectivity to local and wide area networks (LAN/WANS) Specifications For more information call Operating Temperature Range 32°F to 118°F (0°C to 45°C) 1-888-561-7942 Storage Temperature Range 15°F to 118°F (10°C to 45°C) rilVEEDER-ROOT © 2006 Veeder-Root Company • 125 Powder Forest Drive • Simsbury, CT 06070 • USA Telephone: 860-651-2700 • Fax : 860-651-2719 • www.veeder.com VR 13679 P/N 0576047-022 Rev.E VR 4/2006 Printed in USA • i a 0 I Certified perfo:rrnance� for inventory. ` control and' in -tank leak detection in fuel blends up to 100% alcohol f " Veeder-Root offers two types of The TLS -300 and TLS -350(R) equipped, L The 0.2 GPH Mag Probe for Alternative Magnetostrictive Probes for 'Alternative with CSLD use the 0.1 GPI -I Mag Probe to Fluids has also been third -parry tested and ' Fluids to provide highly accurate, trouble- continuously monitor fuel height and tem- certified to exceed U:S. E.PA. standards for free in -tank leak detection and inventory * perature information to detect idle times in 0,2 GPH automatic tank gauging. (See the control in fluids of up to.100% alcohol. The the tank. During each idle time, 'data summary of leak test performance on back Magnetostrictive Probe for Alternative collected forms a highly accurate leak or call us fo'r a copy of the complete test f Fluids with water detection is ideal for fuel detection database. Sophisticated statistical results.) `. blends with less than 20% alcohol. -The analysis techniques in CSLD constantly Magnetostrictive Probe for Alternative evaluate the database to discard invalid data Approved for Aboveground Tank j Fluids without water detection has been and perform leak tests based on only high- Applications developed for fluids up to 1.00% alcohol. quality information in the current'database. Veeder-Root • Magnetostrictive Probes are in fact, a new leak test is performed every approved for use in aboveground storage I Series 8463 0.1 GPH Mag Probe _ time new data from an. idle period is added: tanks to monitor fuel inventory. An AST I ' for Alternative Fluids installation Kit (Form' Number 312020 - The 0.1. GPH Mag Probe for Alternative Series 8463 0.2 GPH Mag Probe 984) is required for these applications and f Fluids has been third -party tested and for Alternative Fluids- is availablefrom"Veeder-Root, Customer certified to perform far better than the U.S. {' The 0.2 GPFI. Mag Probe. for Alternative Service 800-873-3313 or your authorized E.P.A. standards for both 0.1 GPH volu- Fluids provides the same reliable inventory Veeder-Root distributor. " metric tank tightness testing and 0.2 GPi-1 control features and'fluid compatibility as automatic tank gauging. (See the summary the 0.1. GPH Mag Probe for Alternative of leak test performance on back or call us Fluids, but offers 0.2.GPH.leak detection at for a copy of the complete test results.) a lower, cost. MagnetwNciAe Probes ro.arle 0,,eRuds 'are Wa#aua in 0.1 GPH ' 0.1 GPH Mag Probe and CSLD— and 0.2 GPH Uersbns Leak detection ,without shutting down your tanks! - CSi-D, Continuous Statistical Leak Features 8e Benefits Detection, is an advanced tank testing tech- nology that makes full use of the TLS -300 - Non -corrosive, stainless steel tubing 0.1 GPH Mag Probe for Alternative and TIS-350(R)'s in -tank monitoring capa- for long -life monitoring in fuels up to _f=luids is compatible with TLS -300 bilities. CSLD eliminates the need for tank l 1.00% alcohol and TLS -350R with CSLD for w shutdon to perform a leak test— no lost continuous statistical leak detection business, no lost operating time! Highly accurate Magnetostrictive 1 measurement technology 0.2 GPi-I Mag Probe for Alternative Fluids is third -party certified to • fast accurate leak tests exceed U.S. E:P.A. performance '• standards for 0.2 GPH Automatic t 0.1. GPi-1 Mag Probe for Alternative Tank Gauging' ` Fluids is third -party certified to exceed U.S. E.PA. performance 2", 3" and 4".Float Kits available. standards for 0.1 GPFI Volumetric Tank Tightness Testing4-0 l r VEEDER-ROOT Probe Models Mag Plus Probes for Alternative Mag Plus Probes for Alternative Fluids with Water Detection Part No* Fluids without Water Detection Part N TankI.D. -- _�.. .......__ - -- _- .. _. ._ _ -- .. ......... .. _ _ .._.. ., , ......_,. 0.1 GPH Leak 0.2 GPH Leak Inventory 0.1 GPH Leak 0.2 GPH Leak I Inventory Detection Detection Only Detection Detection Only 4' 846391-101 846391-201 1 846391-301 5' 846391-102 846391-202 1 846391-302 5'4" { 846391-103 846391-203 1 846391-303 6' 846391-104 846391-204 1 846391-304 7' + 846391-105 846391-205 1 846391-305 7'6" 846391-106 846391-206 1 846391-306 8' 846391-107 846391-207 1 846391-307 9' t 846391-108 846391-208 1 846391-308 9'6" 846391-117 846391-217 846391-317 �j 846391-109 846391-209 1 846391-309 10'6" 846391-110 846391-210 1 846391-310 11' 846391-111 846391-211 846391-311 12' 846391-112 846391-212 I 846391-312 2.OM 846391-113 846391-213 1 846391-313 2.5M t 846391-114 846391-214 1 846391-314 2.67M I 846391-116 846391-216 1 846391-316 3.OM 846391-115 846391-215 1 846391-315 Custom 1 846391-199 846391-299 846391-399 Length y=2 -> 20' cable Tbar W4 must be ord&W senararely frau prat B . wafer Roalc rpt recarwnarded /or lust bbods with >20% aboW Floats Match Table Product Probe 846391-401 ( 846391-501 846391-601 846391-402 846391-502 846391-602 846391-403 I 846391-503 846391-603 846391-404 I 846391-504 I 846391-604 846391-405 I 846391-505 846391-605 846391-406 I 846391-506 I 846391-606 } 846391-407 846391-507 i 846391-607 {r 846391-408 I 846391-508 I 846391-608 846391-417 846391-517 846391-617 tg4fi 3.-40 1 t 846391-509 I 846391-609 �11-4846391-510 I 846391-610 846391-411 I 846391-511 I 846391-611 846391-412 I 846391-512 I 846391-612 846391-413 ( 846391-513 I 846391-613 846391-414 I 846391-514 846391-614 846391-416 I 846391-516 ( 846391-616 846391-415 I 846391-515 r 846391-615 846391-499 1 846391-599 I 846391-699 Functions Float Kit Leak Test Performance (Third Party Certified for all TLS-3xx Consoles*) PROBE TEST TYPE Inventory: Yes P(FA) TEST TIME Mag Plus Probe for Alternative Fluids with Water Detection Leak Detection: Yes Gasoline Float Kit 1% P/N 846391-1xx or -2xx Water detection: Yes P/N 846400-xy0" Gasoline (<=20% Alcohol) Inventory Only Mag Plus Probe for Alternative Fluids with f Inventory: Yes ('see note for 0.2 GPH 99% <.l% definition of xy 0.2 GPH Mag 2 Water Detection Leak Detection: No below) 2 Hours P/N 846391-3xx Water detection: Yes Alcohol /Ethanol (<=100% Mag Plus Probe for Alternative Fluids without Water Inventory: Yes Alternative Fluids Alcohol, including E85) Detection Leak Detection:Yes Float Kit Methanol (<=100% Alcohol) P/N 846391-4xx or -5xx Water Detection: No i P/N 846400-xy4- ETBE (<=100% Ether) _ Mag Plus Probe for Alternative Fluids without Water MTBE (<=100% Ether) Detection Notes: Used Oil P/N 846391-6xx x=0 -> 4" floats _ t Inventory: Yes i x=1-> 2" floats Fuel Oil #4 & 46 Leak Detection:No x=3 -> 3" floats Fuel Oil #4 & 46 Mag Plus Probe for Alternative Fluids without Water Detection: No Ethylene Glycol Water Detection y=0 -> 5' cable Propylene Glycol P/N 846391-6xx y=1 ->10' cable Windshield Washer Fluid y=2 -> 20' cable Leak Test Performance (Third Party Certified for all TLS-3xx Consoles*) PROBE TEST TYPE P(D) P(FA) TEST TIME 0.1 GPH Mag Probe 0.1 GPH 99% 1% 3 Hours 0.1 GPH Mag Probe 0.2 GPH_ 99% <.l% 2 Hours 0.1 GPH Mag Probe w/CSLD 0.2 GPH 99% <.l% Continuous 0.2 GPH Mag 2 0.2 GPH 99°/a <.l% 2 Hours Vw1ci�Roof rwc- m the riyhl to change pra/uct speci/icaiA n wahow advance notice. Reese wn� a foal you arc xwu the latest version orlxrduct ita atwe. tf VEEDER-ROOT Q 2007 Veeder-Root Company • 125 Powder Forest Drive • Simsbury, CT 06070 • USA t: Telephone: 860-651-2700 • Fax: 860-651-2719 • www veeder.corn VR .1.2960 P/N 577013-054 Rev.0 VR 6/07 Model 305, 305XP & 305XPA Cap and Adaptor The Morrison Bros. Cap and Adaptor are.used for access to leak detection on fuel storage tanks. :1 s� The cap has a center pull ring with toggle cam . x to fit adaptor groove. Tight seal and lockable. The Adaptor is profile machined for cam and groove fit on industry standard tight seal caps. Each cap and adaptor comes with a one year t ff t' f f th d t f warran y (e ec Ive or a year rom e a e o - installation). The EVR Approved Cap and Adaptor are available in a 4" size. a rAj B 305--0000 AA 305---0200 AA ' 305--0200AAEVR 305XP-2100 AC 305XP-2200 AC 305XP-2300 AC 305XP-2400 AC 305XP-0100 AC 305XP-0200 AC 305XP-1100 AC 305XP-1200 AC 305X PA2100 AK 305XPA2200 AK 305XPA230D AK 305XPA2400 AK 305X PA0100 AK 305XPA0200 AK 305XPA110O AK 305XPA120O AK Irk 1305XP-1100ACEVR No NA NA 1.5 No NA %'.SPECIFICATION S SHEET4.11 Yes NA NA 2.4 No 3/8" NA 0.75 No 3/8" 3/8" 0.75 No 1/2" NA 0.75 No 1/2" 1/2" ,�Q' p W AwMtM6 NO Flk NO P1V- No y I e NA 2 No 3/8" 3/8" x 1 No 1/2" NA 2 No 1/2" 1/2" 2 w, s warran y (e ec Ive or a year rom e a e o - installation). The EVR Approved Cap and Adaptor are available in a 4" size. a rAj B 305--0000 AA 305---0200 AA ' 305--0200AAEVR 305XP-2100 AC 305XP-2200 AC 305XP-2300 AC 305XP-2400 AC 305XP-0100 AC 305XP-0200 AC 305XP-1100 AC 305XP-1200 AC 305X PA2100 AK 305XPA2200 AK 305XPA230D AK 305XPA2400 AK 305X PA0100 AK 305XPA0200 AK 305XPA110O AK 305XPA120O AK Irk 1305XP-1100ACEVR No NA NA 1.5 No NA NA 2.4 Yes NA NA 2.4 No 3/8" NA 0.75 No 3/8" 3/8" 0.75 No 1/2" NA 0.75 No 1/2" 1/2" 0.75 No 3/8" NA 2 No 3/8" 3/8" 2 No 1/2" NA 2 No 1/2" 1/2" 2 No 3/8" NA 2.5 No 3/8" 3/8" 2.5 No 1/2" NA 2.6 No 1/2" 1/2" 2.6 No 3/8" NA 5 No 3/8" 3/8" 5 No 1/2" NA 5 No 1/2" 1/2" 5 Yes 1 1/2" 1 NA 1 2 A—Size: 2" or q,. B—Material: Aluminum (AL) or Brass (BR) C—EVR Approved: Yes or No D—Threaded Port Hole: 3/8",1/2" or NA E—Cable Connector. 3/8",1/2" or NA Weight—Shipping Weight ,LL 1 IL f A SPECIFICATION OPTIONS: n i �f I 1 � • i! / ' k. A—Size: 2" or q,. B—Material: Aluminum (AL) or Brass (BR) C—EVR Approved: Yes or No D—Threaded Port Hole: 3/8",1/2" or NA E—Cable Connector. 3/8",1/2" or NA Weight—Shipping Weight 57o E. 7th Street, P.O. Box 238 1 Dubuque, IA 52004-0238 t.563 -583-S701 1 800.553.4840 1 f. 563.583.5028 MORRISONBROS. CO. www.morbros.com n i �f I 1 � • i! / ' k. r f 57o E. 7th Street, P.O. Box 238 1 Dubuque, IA 52004-0238 t.563 -583-S701 1 800.553.4840 1 f. 563.583.5028 MORRISONBROS. CO. www.morbros.com AST INSTALLATION KIT (Note: Junction Box and Cap and Ring Kit not included) ► Kit allows owners of Aboveground Stor- age Tanks (ASTs) to install Veeder-Root's Magnetostrictive Probes In conjunction with the TLS -350R, TLS -350, TLS -300, TLS -300i or TLS -250 Monitoring Systems for more accurate inventory management. ► Rugged outdoor construction with resis- tance to UV radiation and RF noise. ► Ensures safe, easy Installation of Magne- tostrictive Probes. No. Remote monitoring eliminates need to climb on top of the tank for liquid level measurement ► Ideal for vaulted tank applications. ► Veeder- Root's Magnetostrictive Probe measures product level to within +0.01 " and'waterreadings to within +0.10': Veeder -Root's new Aboveground Storage Tank Kit and Magnetostrictive Probes allow owners of ASTs to accurately measure inventory when used with TLS -350R, TLS -350, TLS -300, TLS -300i, TLS -300C or TLS -250 Monitoring Systems. W The rugged outdoor construction of the Kit and the solid-state construction of the Magnetostrictive Probe provide reliable product level measurement to within ±0.01 " and water readings to within ±0.10". The probe operates in a —300 to +70°C temperature range, and measures product temperature in a — 20°C to +50°C. Probes are available for tank diam- eters of 48" to 144". The Kit's flexible conduit grounded to the junction box ensures safe probe installation. The Kit and probe combined with the TLS Monitoring System offers operating safety — data can be monitored remotely by the monitoring system. There is no more need for "sticking" the tank for inventory measurement. Installation Kit Contents (Kit Number 312020-984) • 1— Adaptor • 5 ft.— Flexible Conduit; 3/8 • 2 — Line -tight Connectors, 3/8 STR • 1— Installation Instructions for Magnetostrictive Probes in ASTs %t i M94netostrictive"Probe for AM Console Compatibility t Tfie Series 8473 Magnetostdctive Probes installed in Aboveground Storage Tanks using Kit No. 312020-984 are compatible with the • following consoles: - - -A'F6u ,,, Probe Interface Module'is required for use of magnetostrictive probes with the TLS -350R or TLS -350 System_ -'Y 'TYPIOAI= INSTALLATION: ASTOT PARTS JQENTIFICATION1 STRAIGHT UOUIDTIGHT ' CONNECTORS yR - ` y (SUPPLIED WITH AST Kn) i i WEATHERPROOF FLE)UBL'E METAL CONDUIT JUNCTION BOX WITH (SUPPLIED WITH AST KIT) p, INCH NPT THDS ' . ' (18 CUBIC INCH. i . i - MINIMUM) ._ ; �. I Z• nRE CABLE ' , . 'STRnIGHT UOUIDTIGHT i - (SUPPLIED WITH PROBE) .._ EPDXY SEAL CONNECTOR IH PER NEPA.: (SUVYytU WIIN ABI KJ 1) SPEC RISER DIMENSION - rAOAPTER �a t SHOULD BE 18' MIN. ;Fu xaw METALcoKourr 1 ISUPP_LIED WITH AST KIT) REMKE CORD GRIP TYP HORS TO THE 00770AJ OF SUPPLIED WITH AST - (SUPPLIED WITH PROBE) THE RISER CAP. SEE NOTE BELOW 4.00' &RI, PIPE � Q ' SCHEDULE 40 - - TANk • - MAGNMOSTRICTIVE PROBE ' I . J•eok 1. STRAIOHT UOUIDTIGHT ' CONNECTOA 34•. "(SUPPLIED Wm1 AST KrT). • .. - - • Note: Increase this minimum dimension If the tank +diameter does not match the probe length. (Example: A 7'6" dis. tank Will use an 8' pprobe. The extra probe height will be lodged in the riser pipe, which must be 8" longer than the minimum in order to provide room.) Of '' VEEDER-ROOT' { WM Environmental Products • 7ft L*adwln TV* M rAwft Ted4i wwy 125 Powder Forest Drive, Post Office Boz 2003, Simsbury, CT 06070.2003 TEL: (860) 651-2700, FAX: (860) 651.2719 TECH SUPPORT: (860) 651=2753 BRAZIL• Sao Paulo • CANADA: Mississauga, Ontario ! ENGLAND[ Richmond Surrey - FRANCE_Aulnay-Sous Bols • GERMANY: Aldingen ! SINGAPORE: Singapore 12940 PM 577013.279 AR)1 U,S.A, 06 TLS -350H Cont;til¢s' TLS -350 Consoles" TLS -300 System.—I' TLS -3001 System•.. ,'_ _ TLS -3000. TLS -25D System -• `.TLS•Z50I System ';;Series 8482. '' Series 8470: _ Series 8485 Series 8485_Serie's 8485 .; Series 7841- •Series';7941.: Veeder-Root Sensor Application Guide Interstitial Sensors for Steel Tanks The Interstitial Sensor for Steel Tanks detects the presence of liquid between the double walls of the tank. Sensor Detection Capabilities - Alarm Conditions • The presence of any liquid at a nominal height of 1 inch in the tank's interstitial space triggers a Fuel Alarm. • An open sensor triggers a Sensor Out alarm. Operating Capabilities • Operating temperature range: 0 to +70°C (for water), -20 to 70°C (for hydrocarbons). • Storage temperature range: -40 to +70°C. • Sensor dimensions: 2.5" high, 1.5" diameter. Sensor Interface Module • TLS -350 Series Consoles (except TLS -350J) - Interstitial/Liquid Sensor Interface Module (P/N 329358-001) accepts up to 8 sensors (a maximum of 64 sensors could be monitored by the console). • TLS -350J Console - 3 sensors max. • TLS -300i, PC -300i, TLS -300C, TLS -300J, PC -300C Consoles (no Interface Module required) - 8 sensors max. • ILS -350 Console -A Two -Wire Module (P/N 329675-001) accepts up to 4 sensors (a maximum of 16 sensors could be monitored by the console). Console Software Compatibility • Version 1 or later (TLS -350 Series/TLS-300 Consoles) • All ILS -350 Consoles Compatible Fuels • Unleaded gasoline • Unleaded with up to 5% methanol, 15% ethanol, or 15% MTBE • Leaded gasoline • Diesel • Kerosene • Jet fuel • Aviation gasoline Sensor/Cable Length Configurations Q Qnterstitial'Sensor_with 1 t3=foot cab► (For_m _N umbe rr_794390=420) Interstitial Sensor with w-funt cam -- Form Number 794390-460 Accessories Riser cap and adaptor kit (2"'Kit Number 312020=928) Related Sales Literature Visit our website at www.veeder.com for more information on Veeder-Root products and services. 14" min. dia. manhole \ \ Cord grip r a"ry•a:� AL1 �` x.s a3r p� 9s 1/2" to 2" � Reducer r— Seal -off u 1/2" rigid conduit Leader cable (to Console) Weatherproof junction box with 1/2 -inch N.P.T. 2" dia. riser threads (16 Cubic inch volume minimum) Sensor Steel tank Sensor Switch must rest on bottom of tank Fig. 8 Typical Interstitial Sensor Installation - Steel LIST 12 !1 • Veeder-Root Sensor Application Guide Sump Sensor The sensor is installed in a tank piping sump and will detect the presenc6 of a liquid. Liquid level is monitored by a float /magnetic reed switch sensing system. Sensor Detection Capabilities Alarm Conditions • Fuel alarm is triggered when liquid reaches a nominal height of 1 -inch. • An open sensor triggers a Sensor Out alarm. Operating Capabilities • Operating temperature range: 0 to +60°C. • Storage temperature range: 40 to +70°C. Sensor dimensions: 12" high, 1.9" diam eter. ,Sensor Interface Module • TLS -350 Series Consoles (except TLS -350J) - Interstitial/Liquid S6nsor Interface Module (FIN 329358-001) accepts up to 8 sensors (a maximum of 64,sensors could be monitored by the console).- • Tl_S-350,11Console - 3 sensors max. • TLS-300/PC-300 Series Consoles (no Interface Module required) 8 sensors"max. • ILS -350 Console - A Two -Wire Module (P/N 329675-001) accepts up to 4 sensors (a maximum of 16 sensors - could be monitored by the console). Console Software Compatibility • Version 1 or later (TLS -350 Series/TLS-300 Consoles) • All ILS -350 Consoles Compatible Fuels, • Unleaded gasoline • Unleaded with up to 5% methanol,, 15% ethanol, or 15% MTBE Leaded gasoline Diesel • Kerosene 0 Jet fuel. . Aviation gasoline' Related Sales Literature Visit our website at wwwveeder.com for more information on Veeder-Root products and services. CM9.T—MFrL777777_77:7 DO NOT MOUNT SENSOR TO '`—Existing conduit FLEXIBLE PRODUCT LINE. or piping a me Product Cable to junction box Cable to junction pipe t0ju ctio nd seal -off and seal -off box an *Sump sensor should: 4 •1. Rest on the base of the sump. 2. Be positioned as close to outer 7 wall as possible. Sump sensor* 3. Be mounted in a true vertical (installation examples) position. 4. Be installed only in a dry sump.' ump base Fig. 2 Typical Sump Sensor Installation 5 0 ► Audible horn and flashing light provide an early warning of potential tank bulk delivery overfills. ► Wired to one of the built-in alarm relays in a TLS -300, TLS -3001, TLS -250 or TLS 2501 System or to an 1/0 Combination Module or a Four -Relay Output Module in the TLS -350 or TLS -3508. ► Programmable overfill alarm limits can be set for each tank at a TLS System location. ► Built-in timer lets you adjust length of time that the audible alarm will stay on from 0 to 60 seconds. ► Adjust noise level from 78 to 103 dB (at 10 feet). ► Optional alarm acknowledgment switch Is available for locations where driver Intervention Is required by local codes. Audible and Visual Warnings of Potential Overfills Veeder-Root's TLS Overfill Alarm provides an early warning of potential tank bulk delivery overfills as required by the Federal regulations governing underground storage tanks. Wired to an alarm relay in a TLS -350R, TLS -350, TLS -300, TLS -300i, TLS -250 or TLS -250i System, the alarm relay activates the TLS overfill alarm horn and light when a potential overfill is detected. All TLS systems have programmable overfill alarm limits that can be set for each tank at a location. An optional Alarm Acknowledgement Switch is also available for locations where driver intervention is required by local codes. When the driver presses the acknowledgement button, the overfill alarm shuts off and the alarm acknowledgement light illuminates. This light will stay on until the TLS prints an inventory increase report. SPECIFICATIONS General ► Enclosure: Painted steel, NEMA 4; 1/2" conduit connector at bottom of alarm and at left side of acknowledgement switch. ► Operating Temperature Range: -40° to i 150'F ► Supply Voltage: 120 VAC, 50160 Hz. Alarm Unit ► Actuation: From TLS alarm contact. ► Audible Alarm: • Output: Adjustable "Time On" from 0 to 60 seconds. ► Visual Alarm: • Lamp Rating 25 watt., 120 VAC. • Lens: Red Polycarbonate. • Flashing Rate: 75 per minute. ► Dimensions: 11 " lung, 7" wide, 4" deep. Alarm Acknowledgement Switch ► Function: Turns off alarm unit while actuating acknowledgement lamp. ► Acknowledgement Lamp: 120 VAC. Amber lens. ► Dimensions: 7" long, 3" deep. OWNER: PROJECT LOCATION. SHEET N0, FS -165-01 FS -165-02.1 FS -165-02.2 FS -165-03.1 FS -165-05.1 FS -165-06.1 FS -165-06.2 FS -165-09.1 FS -165-09.2 E-165-03.1 E-165-09.1 E-165-09.2 CALIFORNIA HIGHWAY PATROL 420 BAKERSFIELD FIELD AND DISPATCH OFFICE REPLACEMENT BAKERSFIELD, CALIFORNIA STATE OF CALIFORNIA DEPARTMENT OF GENERAL SERVICES 9855 COMPAGNONI STREET, BAKERSFIELD, CALIFORNIA, 93313 SHEET NAME COVER SHEET NOTES AND LEGEND EQUIPMENT SCHEDULE SITE PLAN ENLARGED FUEL TANK LAYOUT TRANSVERSAL VIEW LONGITUDINAL VIEW FUEL SYSTEM DETAILS FUEL SYSTEM DETAILS ELECTRIC AREA CLASSIFICATION ELECTRICAL DETAILS ELECTRICAL DETAILS 4. SCOPE OF WORK INSTALL - ONE (1) 12,000.00 GALLONS "MODERN WELDING" ABOVEGROUND DOUBLE WALL GASOLINE TANK - TWO (2) SINGLE PRODUCT "WAYNE' GASOLINE DISPENSERS. - TWO (2) ABOVEGROUND "BRAVO" DISPENSER CONTAINMENT BOXES. - ONE (1) "FUEL MASTER' FUEL MANAGEMENT SYSTEM NOTES: ALL CODES REFER PER C.F.C. 2013 EDITION AND C.B.C. 2013 EDITION: 1. THE TANK IS A "MODERN WELDING" 12,000 GALLON -PROTECTED TANK TESTED. AND LISTED IN ACCORDANCE WITH U L 2085 AS -PER CFC 340 SAND KFPA.-303 NK CONSTRUCTION SHALL BE IN ACCORDANCE WITH C.F.C. 2013 AS PER 2. �A SECTION 3404.2.7. 3. PRIOR TO TANK DELIVERY CONTRACTOR SHALL PROVIDE MANUFACTURER'S TEST RESULT'FOR SPECIFIC TANK TO SHOW THAT THEY PASSED FACTORY PRESSURE TEST. 4. TANK SUPPORT STRUCTURES SHALL BE DESIGNED IN ACCORDANCE WITH THE C.B.C. 2013, N.F.P.A. 30 AND SECTION 3404.2.9.3 PER C.F.C. 2013. 5. TANKS TO BE ANCHORED IN ACCORDANCE WITH SEISMIC CALCULATIONS AS PER C.F.C. 2013 SECTION 3404.2.9.3. , 6. TANK OPENINGS IN PROTECTED ABOVE -GROUND TANKS SHALL BE THROUGH THE TOP ONLY AS PER C.F.C. 2013 SECTION 3404.2.9.7.9. 7. APPROVED ANTISIPHON DEVICES SHALL BE INSTALLED IN EACH EXTERNAL PIPE CONNECTED TO THE PROTECTED ABOVE -GROUND TANK WHEN THE PIPE EXTENDS BELOW THE LEVEL OF THE TOP OF THE TANK AS PER C.F.C. 2013 SECTION 3404.2.9.7.10. 8. PROVIDE VENTING IN ACCORDANCE WITH C.F.C. 2013 SECTION 3404.2.7.3. VENT PIPE OUTLETS FOR TANKS STORING CLASS I, II OR IIIA LIQUIDS SHALL BE LOCATED SUCH THAT THE VAPORS ARE RELEASED AS A SAFE POINT OUTSIDE OF BUILDINGS AND NOT LESS THAN 12 FEET (3658 MM) ABOVE THE ADJACENT GROUND LEVEL VAPORS SHALL BE DISCHARGED UPWARD OR HORIZONTALLY AWAY FORM ADJACENT WALLS TO ASSIST IN VAPOR DISPERSION. VENT OUTLETS SHALL BE LOCATED SUCH THAT FLAMMABLE VAPORS WILL NOT BE TRAPPED BY EAVES OR OTHER OBSTRUCTIONS AND SHALL BE AT LEAST 5 FEET (1524 MM) FROM BUILDING OPENINGS OR LOT LINES OF PROPERTIES THAT CAN BE BUILT UPON. VENT OUTLETS ON ATMOSPHERIC TANKS STORING CLASS IIIB LIQUIDS ARE ALLOWED TO DISCHARGE INSIDE A BUILDING IF THE VENT IS A NORMALLY CLOSED VENT. 9. STATIONARY, ABOVE -GROUND TANKS -SHALL BE EQUIPPED WITH ADDITIONAL VENTING THAT WILL RELIEVE EXCESSIVE INTERNAL PRESSURE CAUSED BY EXPOSURE TO FIRES. EMERGENCY VENTS FOR CLASS I, II AND IIIA LIQUIDS SHALL NOT DISCHARGE INSIDE BUILDINGS.THE VENTING SHALL BE INSTALLED AND MAINTAINED IN ACCORDANCE WITH SECTION 22.7 OF N. F.P. A. 30 AS PER C.F.C. 2013 SECTION 3404.2.7.4. r r + i fail H Wy,..__ Atlix NOWNAW �r 4� I� ,-0conow Ad VICINITY MAP: SCALE. N. T. S. 10. TANK LOCATION AND SEPARATION IN ACCORDANCE WITH TABLE 2206.2.3. C. F. C. 2013. 11. WHEN THE INDIVIDUAL TANK CAPACITY IS LESS THAN OR EQUAL TO 6,000 GALLONS THE MINIMUM DISTANCE FROM LOT LINE THAT IS OR CAN BE BUILT UPON, INCLUDING THE OPPOSITE SIDE OF A PUBLIC WAY IS 15 FEET. THE MINIMUM DISTANCE FROM NEAREST SIDE OF ANY PUBLIC WAY OR FROM NEAREST IMPORTANT BUILDING ON THE SAME PROPERTY IS 5 FEET. WHEN THE INDIVIDUAL TANK CAPACITY IS GREATER THAN 6,000 GALLONS, THE ABOVE DISTANCE ARE INCREASED TO 25 FEET AND 15 FEET RESPECTIVELY AS PER TABLE 2206.2.3. C.F.C. 2013. 12. PROTECTED ABOVE -GROUND TANKS SHALL NOT BE FILLED IN EXCESS OF 95% OF THEIR CAPACITY. AN OVERFILL PREVENTION SYSTEM SHALL BE PROVIDED FOR EACH TANK. DURING TANK -FILLING OPERATIONS, THE SYSTEM SHALL. COMPLY WITH ONE OF THE FOLLOWING: 1.THE SYSTEM SHALL - 1.2 AUTOMATICALLY SHUT OFF THE FLOW OF FUEL TO THE TANK WHEN THE QUANTITY OF LIQUID IN THE TANK REACHES 95% OF TANK CAPACITY. FOR RIGID HOSE FUEL -DELIVERY SYSTEMS, AN APPROVED MEANS SHALL BE PROVIDED TO EMPTY THE FILL HOSE INTO THE TANK AFTER THE AUTOMATIC SHUTOFF DEVICE IS ACTIVATED. AS PER C.F.C. 2013 SECTION 3404.2.9.7.6. (1.2) 13. A PERMANENT SIGN SHALL BE PROVIDED AT THE FILL POINT FOR THE TANK, DOCUMENTING THE FILLING PROCEDURE AND THE TANK CALIBRATING CHART AS PER C.F.C. 2013 SECTION 3404.2.9.7.6.1. 14. TANK SHALL BE WITH AN INDEPENDENT MEANS OF NOTIFYING THE PERSON FILLING THE TANK THAT THE FLUID LEVEL HAS REACHED 90% OF TANK CAPACITY BY PROVIDING AN AUDIBLE OR VISUAL ALARM SIGNAL, PROVIDING A TANK LEVEL GAUGE MARKED AT 90% OF TANK CAPACITY OR OTHER APPROVED MEANS AS PER C.F.C. 2013 SECTION 3404.2.9.7.6 (1.1) 15. A SPILL CONTAINER HAVING A CAPACITY OF NOT LESS THAN 5 GALLONS (19L) SHALL BE PROVIDED FOR EACH FILL CONNECTION. FOR TANKS WITH A TOP FILL CONNECTION, SPILL CONTAINERS SHALL BE NONCOMBUSTIBLE AND SHALL BE FIXED TO THE TANK AND EQUIPPED WITH A MANUAL DRAIN VALVE THAT DRAINS INTO THE PRIMARY TANK. FOR TANKS WITH A REMOTE FILL CONNECTION, A PORTABLE SPILL CONTAINER SHALL BE ALLOWED AS PER C.F.C. 2013 SECTION 3404.2.9.7.8. 1+, 99 '' �6orranyton Are Q _ +cem su,hoa!<Are -14edM vYby.:2, AfmE I I Z i PROJECT LOCATION TaftHw+V`. .�_ _Z ,,laft Rvyy_,.. Vu#ry "nufactuled y i _t� Hwnex f F FCurnow Rd O NORTH 16. FILL OPENINGS SHALL BE EQUIPPED WITH A LOCKING CLOSURE DEVICE. FILL OPENINGS SHALL BE SEPARATE FROM VENT OPENINGS AS PER 2013 C.F.C. SECTION 3406.2.4.1. 17. THE DESIGN, FABRICATION AND INSTALLATION OF FUEL -DISPENSING SYSTEMS FOR FLAMMABLE OR COMBUSTIBLE LIQUID FUELS SHALL BE IN ACCORDANCE WITH SECTIONS 2206.7.1 THROUGH 2206.7.9.2.4 AS PER 2013 C.F.C. SECTION 2206.7. CLASS I AND II LIQUIDS SHALL BE TRANSFERRED FROM TANKS BY MEANS OF FIXED PUMPS DESIGNED AND EQUIPPED TO ALLOW CONTROL OF THE FLOW AND PREVENT LEAKAGE OR ACCIDENTAL DISCHARGED, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: A. A LISTED AUTOMATIC -CLOSING -TYPE HOSE NOZZLE WITH AN INTEGRAL LATCH OPEN DEVICE SHALL BE PROVIDED AS PER 2013 C.F.C. SECTION 2206.7.6. B. DISPENSER HOSES SHALL BE A MAXIMUM OF 18 FEET (5486 MM) IN LENGTH AS PER 2013 C.F.C. SECTION 2206.7.5, EQUIPPED WITH A LISTED EMERGENCY BREAKAWAY DEVICE DESIGNED TO RETAIN LIQUID ON BOTH SIDES OF A BREAKAWAY POINT AS PER 2013 C.F.C. SECTION 2206.7.5.1. 18. PIPING SYSTEM AND THEIR COMPONENT PARTS, FOR FLAMMABLE AND COMBUSTIBLE LIQUIDS SHALL BE IN ACCORDANCE WITH C.F.C. 2013 SECTION 3403.6. 19. THE SUCTION PUMP IS MOUNTED DIRECTLY ON THE TANK IN THIS CASE WE DO NOT HAVE ANY PIPING ON THE EXTERIOR OF THE TANK AND A PIPING PRESSURE TEST IS NOT APPLICABLE IN THIS CASE. NO C o - -. 20. ABOVE -GROUND TANKS FOR THE STORAGE OF LIQUID MOTOR FUELS SHALL BE f SAFEGUARDED FROM PUBLIC,ACCESS OR,UNAUTHORIZED ENTRY IN,AN APPROVED MANNER AS PER C.F.C. 2013 SECTION 2206.3. STORAGE AREAS SHALLBEPROTECTED AGAINST TAMPERING OR TRESPASSERS BY FENCING -OR ' OTHER APPROVED CONTROL MEASURES AS PER.2013 C.F.C. SECTION 3404.4.4. 21 GUARD,POSTS OR OTHER MEANS SHALL BE PROVIDED TO PROTECT EXTERIOR STORAGE TANKS, FROM VEHICULAR DAMAGE. WHEN GUARD POSTS ARE ' INSTALLED,,. THE.POSTS'SHALL BE INSTALLED!.IN,A000RDANCE WITH 2013 ` C.F.C.-SECTION 312.2: ., "A.'_CONSTRUCTED OF STEEL NOT LESS THAN 4" r INCHESY(f02 AMM) °IN DIAMETER 'AND "� 4. Y cnn w * w CONCRETE FILLED. r, B. 'SPACED NOT . MORE THAN 4,'FEET (1219 MM) BETWEEN POSTS ON CENTER. C. SET NOT LESS -THAN 3 'FEET (914 MM) DEEP IN A'CONCRETE FOOTING' OF NOT LESS THAN 15 -INCH (381 MM) DIAMETER. D. SET WITH THE TOP OF THE POSTS NO LESS THAN 3 -FEET (914 -MM) ABOVE GROUND. E. LOCATED NOT LESS THAN 3 FEET (914.MM) FROM THE PROTECTED OBJECT `•t 2Z SIGNACE SHALL CONTAIN,THE FOLLOWING AND BE VISIBLE THROUGHOUT THE TANK A. PROVIDE HAZARDOUS 'IDENTIFICATION SIGNS ON TANKS' AS PER 2013 .C. F. C.' SECTION 2703.5 AND 2703.6. • a B. TANKS MORE THAN 100 GALLONS (379L),IN CAPACITY .WHICH ARE _ PERMANENTLY INSTALLED OR MOUNTED AND USED -FOR THE STORAGE OF, CLASS I, II OR IIIA LIQUIDS, SHALL BEAR • A LABEL AND PLACARD , - IDENTIFYING THE MATERIAL THEREIN. PLACARDS SHALL BE IN ACCORDANCE WITH N F. P. A. 704 AS PER 2013 C. F. C. 'SECTION 3404.2.3.2. F C.' MINIMUM • N. F. P.A. '704-M PLACARD . SIZE. 15 . INCHES X,15 INCHES + # HEALTH HAZARD FIRE HAZARD (BLUE) (RED) ' REACTIVITY HAZARDSPECIAL HAZARD--" + (YELLOW) ro• (WHITE)' ' 3 HAZARDOUS MATERIAL SIGN' t4 3 0 FOR GASOLINE FUEL • _ , - D. PRODUCT IDENTIFICATION.• "DIESEL FUEL"' 'GASOLINE FUEL"" E. WARNING SIGNS SHALL BE CONSPICUOUSLY POSTED WITHIN SIGHT OF EACH 4 DISPENSER IN THE FUEL -DISPENSING AREA AS PER 2013 C.F.C.-SECTION • - - . 2205.6 AND SHALL STATE THE FOLLOWING: ` 1. "NO SMOKING OR OPEN FLAMES WITHIN 50 FEET' 2. "SHUT OFF MOTOR" 3. DISCHARGE YOUR STATIC ELECTRICITY BEFORE FUELING BY TOUCHING•A _ T• sem, _METAL SURFACE AWAY FROM THE NOZZLE. 4. TO PREVENT STATIC CHARGE, DO NOT,REENTER YOUR VEHICLE WHILE r GASOLINE IS PUMPING. 5. ..IF. A FIRE STARTS, DO NOT REMOVE NOZZLE -BACK AWAY IMMEDIATELY. 6. -IT IS UNLAWFUL AND DANGEROUS TO DISPENSE GASOLINE. INTO UNAPPROVED CONTAINERS.• ^7. NO FILLING OF PORTABLE CONTAINERS IN OR ON A MOTOR VEHICLE. PLACE CONTAINER ON GROUND BEFORE FILLING. 8. "NO CELL PHONE USE'. ' F. EMERGENCY PROCEDURES SIGNAGE: " "IN CASE OF FIRE, SPILL OR RELEASE", 1. USE EMERGENCY PUMP SHUT OFF SWITCH. REPORT THE ACCIDENT. FIRE DEPARTMENT TELEPHONE. 911 FACILITY ADDRESS: '9855'COMPAGNONI STREET, BAKERSFIELD. CALIFORNIA, _ 93313 F. ALL SIGNS SHALL BE ON UV PROTECTIVE MATERIALS WHICH WILL WITHSTAND HARSH SALT AIR ENVIRONMENT OF THE PORT OF LONC•BEACH. 23. ELECTRICAL BY OTHERS. AN ELECTRICAL PLAN SPECIFIC TO TXE ' INSTALLATION SHALL BE PROVIDED PRIOR TO BEGINNING WORK CITY OF BAKERSFIELD 24• ELECTRICALWIRING AND EQUIPMENT SHALL BE INSTALLED AND MAINTAINED PLANS & PROJECT MUST FULLY COMPLY WITH IN ACCORDANCE WITH CALIFORNIA ELECTRICAL CODE AS.PER 2013 C.F.C. SECTION 3403. - ALL APPLICABLE CODES. ERRORS AND/OR r ,. 4: • OMMISSIONS DURING PLAN CHECK DOES NOT 25. WHEN PROCESSES OR CONDITIONS EXIST .WHERE' A FLAMMABLE MIXTURE RELIEVE OWNERS AND/OR CONTRACTORS OF: COULD BE IGNITED BY STATIC ELECTRICITY, MEANS SHALL BE PROVIDED TO PREVENT THE ACCUMULATION OF A STATIC CHARGE AS PER 2013 C.F.C. THIS RESPONSIBILITY. FINAL OCCUPANCY AND SECTION 27o3a. s. - - ACCEPTANCE IS SUBJECT TO ONSITE 26. . AN APPROVED, CLEARLY IDENTIFIED AND . READILY ACCESSIBLE EMERGENCY INSPECTION & APPROVAL DISCONNECT SWITCH SHALL BE'PROVIDED AT AN APPROVED LOCATION, TO STOP'THE TRANSFER OF FUEL TO THE FUEL DISPENSERS IN THE EVENT OF A FUEL SPILL OR OTHER EMERGENCY. AN EMERGENCY DISCONNECT SWITCH FOR EXTERIOR FUEL DISPENSER'SHALL BE LOCATED WITHIN 100 FEET. (30, 480 MM) ' OF, BUT NOT LESS THAN 20 FEET (6096 MM) , FROM, THE FUEL " m HL ff It DISPENSERS. FOR INTERIOR FUEL -DISPENSING OPERATIONS, THE EMERGENCY LIME DISCONNECT SWITCH SHALL BE INSTALLED AT AN APPROVED LOCATION SUCH, DEVICES SHALL BE DISTINCTLY LABELED AS: EMERGENCY FUEL SHUTOFF. r _ SIGNS SHALL BE PROVIDED IN APPROVED LOCATIONS 27. APPROVED PORTABLE FIRE EXTINGUISHER COMPLYING WITH SECTION 906 WITH A MINIMUM RATING•OF 2-A:20-B:C SHALL BE PROVIDED AND LOCATED SUCH THAT AN EXTINGUISHER IS NOT MORE THAN 75 FEET (22,860 MM) FROM PUMPS, DISPENSERS OR STORAGE TANK FILL -PIPE OPENINGS 'AS PER 2013 C.F.C.' SECTION 2205.5. NOTE: IF DWG. IS Revlsims • No. Description ' LEGEND. AND ABBREVIATION ' ,SYMBOL ABBREV. DESCRIPTION CO CLEANOUT - WOO Fes- WALL VALVE CV w - , 4 r ' CATE VALVE - DIA-_ NO C o - -. 20. ABOVE -GROUND TANKS FOR THE STORAGE OF LIQUID MOTOR FUELS SHALL BE f SAFEGUARDED FROM PUBLIC,ACCESS OR,UNAUTHORIZED ENTRY IN,AN APPROVED MANNER AS PER C.F.C. 2013 SECTION 2206.3. STORAGE AREAS SHALLBEPROTECTED AGAINST TAMPERING OR TRESPASSERS BY FENCING -OR ' OTHER APPROVED CONTROL MEASURES AS PER.2013 C.F.C. SECTION 3404.4.4. 21 GUARD,POSTS OR OTHER MEANS SHALL BE PROVIDED TO PROTECT EXTERIOR STORAGE TANKS, FROM VEHICULAR DAMAGE. WHEN GUARD POSTS ARE ' INSTALLED,,. THE.POSTS'SHALL BE INSTALLED!.IN,A000RDANCE WITH 2013 ` C.F.C.-SECTION 312.2: ., "A.'_CONSTRUCTED OF STEEL NOT LESS THAN 4" r INCHESY(f02 AMM) °IN DIAMETER 'AND "� 4. Y cnn w * w CONCRETE FILLED. r, B. 'SPACED NOT . MORE THAN 4,'FEET (1219 MM) BETWEEN POSTS ON CENTER. C. SET NOT LESS -THAN 3 'FEET (914 MM) DEEP IN A'CONCRETE FOOTING' OF NOT LESS THAN 15 -INCH (381 MM) DIAMETER. D. SET WITH THE TOP OF THE POSTS NO LESS THAN 3 -FEET (914 -MM) ABOVE GROUND. E. LOCATED NOT LESS THAN 3 FEET (914.MM) FROM THE PROTECTED OBJECT `•t 2Z SIGNACE SHALL CONTAIN,THE FOLLOWING AND BE VISIBLE THROUGHOUT THE TANK A. PROVIDE HAZARDOUS 'IDENTIFICATION SIGNS ON TANKS' AS PER 2013 .C. F. C.' SECTION 2703.5 AND 2703.6. • a B. TANKS MORE THAN 100 GALLONS (379L),IN CAPACITY .WHICH ARE _ PERMANENTLY INSTALLED OR MOUNTED AND USED -FOR THE STORAGE OF, CLASS I, II OR IIIA LIQUIDS, SHALL BEAR • A LABEL AND PLACARD , - IDENTIFYING THE MATERIAL THEREIN. PLACARDS SHALL BE IN ACCORDANCE WITH N F. P. A. 704 AS PER 2013 C. F. C. 'SECTION 3404.2.3.2. F C.' MINIMUM • N. F. P.A. '704-M PLACARD . SIZE. 15 . INCHES X,15 INCHES + # HEALTH HAZARD FIRE HAZARD (BLUE) (RED) ' REACTIVITY HAZARDSPECIAL HAZARD--" + (YELLOW) ro• (WHITE)' ' 3 HAZARDOUS MATERIAL SIGN' t4 3 0 FOR GASOLINE FUEL • _ , - D. PRODUCT IDENTIFICATION.• "DIESEL FUEL"' 'GASOLINE FUEL"" E. WARNING SIGNS SHALL BE CONSPICUOUSLY POSTED WITHIN SIGHT OF EACH 4 DISPENSER IN THE FUEL -DISPENSING AREA AS PER 2013 C.F.C.-SECTION • - - . 2205.6 AND SHALL STATE THE FOLLOWING: ` 1. "NO SMOKING OR OPEN FLAMES WITHIN 50 FEET' 2. "SHUT OFF MOTOR" 3. DISCHARGE YOUR STATIC ELECTRICITY BEFORE FUELING BY TOUCHING•A _ T• sem, _METAL SURFACE AWAY FROM THE NOZZLE. 4. TO PREVENT STATIC CHARGE, DO NOT,REENTER YOUR VEHICLE WHILE r GASOLINE IS PUMPING. 5. ..IF. A FIRE STARTS, DO NOT REMOVE NOZZLE -BACK AWAY IMMEDIATELY. 6. -IT IS UNLAWFUL AND DANGEROUS TO DISPENSE GASOLINE. INTO UNAPPROVED CONTAINERS.• ^7. NO FILLING OF PORTABLE CONTAINERS IN OR ON A MOTOR VEHICLE. PLACE CONTAINER ON GROUND BEFORE FILLING. 8. "NO CELL PHONE USE'. ' F. EMERGENCY PROCEDURES SIGNAGE: " "IN CASE OF FIRE, SPILL OR RELEASE", 1. USE EMERGENCY PUMP SHUT OFF SWITCH. REPORT THE ACCIDENT. FIRE DEPARTMENT TELEPHONE. 911 FACILITY ADDRESS: '9855'COMPAGNONI STREET, BAKERSFIELD. CALIFORNIA, _ 93313 F. ALL SIGNS SHALL BE ON UV PROTECTIVE MATERIALS WHICH WILL WITHSTAND HARSH SALT AIR ENVIRONMENT OF THE PORT OF LONC•BEACH. 23. ELECTRICAL BY OTHERS. AN ELECTRICAL PLAN SPECIFIC TO TXE ' INSTALLATION SHALL BE PROVIDED PRIOR TO BEGINNING WORK CITY OF BAKERSFIELD 24• ELECTRICALWIRING AND EQUIPMENT SHALL BE INSTALLED AND MAINTAINED PLANS & PROJECT MUST FULLY COMPLY WITH IN ACCORDANCE WITH CALIFORNIA ELECTRICAL CODE AS.PER 2013 C.F.C. SECTION 3403. - ALL APPLICABLE CODES. ERRORS AND/OR r ,. 4: • OMMISSIONS DURING PLAN CHECK DOES NOT 25. WHEN PROCESSES OR CONDITIONS EXIST .WHERE' A FLAMMABLE MIXTURE RELIEVE OWNERS AND/OR CONTRACTORS OF: COULD BE IGNITED BY STATIC ELECTRICITY, MEANS SHALL BE PROVIDED TO PREVENT THE ACCUMULATION OF A STATIC CHARGE AS PER 2013 C.F.C. THIS RESPONSIBILITY. FINAL OCCUPANCY AND SECTION 27o3a. s. - - ACCEPTANCE IS SUBJECT TO ONSITE 26. . AN APPROVED, CLEARLY IDENTIFIED AND . READILY ACCESSIBLE EMERGENCY INSPECTION & APPROVAL DISCONNECT SWITCH SHALL BE'PROVIDED AT AN APPROVED LOCATION, TO STOP'THE TRANSFER OF FUEL TO THE FUEL DISPENSERS IN THE EVENT OF A FUEL SPILL OR OTHER EMERGENCY. AN EMERGENCY DISCONNECT SWITCH FOR EXTERIOR FUEL DISPENSER'SHALL BE LOCATED WITHIN 100 FEET. (30, 480 MM) ' OF, BUT NOT LESS THAN 20 FEET (6096 MM) , FROM, THE FUEL " m HL ff It DISPENSERS. FOR INTERIOR FUEL -DISPENSING OPERATIONS, THE EMERGENCY LIME DISCONNECT SWITCH SHALL BE INSTALLED AT AN APPROVED LOCATION SUCH, DEVICES SHALL BE DISTINCTLY LABELED AS: EMERGENCY FUEL SHUTOFF. r _ SIGNS SHALL BE PROVIDED IN APPROVED LOCATIONS 27. APPROVED PORTABLE FIRE EXTINGUISHER COMPLYING WITH SECTION 906 WITH A MINIMUM RATING•OF 2-A:20-B:C SHALL BE PROVIDED AND LOCATED SUCH THAT AN EXTINGUISHER IS NOT MORE THAN 75 FEET (22,860 MM) FROM PUMPS, DISPENSERS OR STORAGE TANK FILL -PIPE OPENINGS 'AS PER 2013 C.F.C.' SECTION 2205.5. NOTE: IF DWG. IS Revlsims • No. Description ' LEGEND. AND ABBREVIATION ' ,SYMBOL ABBREV. DESCRIPTION CO CLEANOUT - WOO Fes- WALL VALVE CV w - CHECK VALVE - GV CATE VALVE - DIA-_ 0 DIAMETER._ 41 ICW _ -Imo+-'_ r INDUSTRIAL COLD. WATER. •_ PRV ""PRESSURE REDUCING"VALVE SOV/COCK SOV OR GAS COCK ON RISER WITH AP AS REQUIRED HB. HOSE BIBB -- c— DROP ' -- a- r RISE -- UNION OR LEFT & RIGHT COUPLING AS REQUIRED SOV SHUT-OFF VALVE IN BOX ---- SOLENOID VALVE ---- FLOW CONTROL VALVE SCD -sw- SECONDARY CONDENSATE DRAIN OD OO -OVERFLOW DRAIN RD O "ROOF DRAIN y AD AREA DRAIN a• AFR `=-AUTOMOTIVE FUEL RECOVERY. PIPING AFS -AUTOMOTIVE FUEL SUPPLY PIPING AFV AUTOMOTIVE FUEL VENT PIPING AFD AUTOMOTIVE FUEL DISPENSING A. G. ABOVE GROUND BEL BELOW BI BLACK IRON CFH. CUBIC FOOT PER HOUR' COMP. COMPARTMENT ' CONN CONNECTION ' CONT CONTINUATION DIA. DIAMETER DN DOWN E. S. 0. EMERGENCY SHUT OFF FG FINISHED GRADE F.O.R. FUEL OIL RETURN + F.O.S. FUEL OIL SUPPLY • • GD ;GASOLINE DISPENSER GPM GALLON PER MINUTE GS GASOLINE SUPPLY - HOR HEADER HORZ•• HORIZONTAL HR 'HOSE REEL. HZ HERTZ If INVERT ELEVATION.'= MFGR MANUFACTURER ^, MLD MECHANICAL LEAK DETECTOR M0__ MOTOR OIL PIPING MOP MOTOR OIL PUMP MOV MOTOR OIL VENT PIPING MOWS WASTE OIL VENT PIPING MTD. MOUNTED PH '. -' PHASE POC POINT OF CONNECTION SF SQUARE FOOTAGE . S.O.V. SHUT-OFF VALVE S.S. STAINLESS STEEL TO TRENCH DRAIN TYP.• . TYPICAL U. G. - UNDER GROUND V .•VOLTAGE VERT. VERTICAL V.R. ` VAPOR RETURN V.T.R VENT THRU ROOF' W/_ WITH VI ' 24" X 18" IT IS NOT FULL SIZE PETERSON HYDRAULICS INC. 1653W. EL SEGUNDO BLVD., GARDENA, CA, 90249; ph:(310)-323.3155 a 'BH CALIFORNIA HIGHWAY PATROL - FIELD AND DISPATCH OFFICE REPLACEMENT NOTES AND'E'EGEND 9855 COMPAGNONI STREET, BAKERSFIELD. CALIFORNIA, 93313 ' z cafe: AS NOTEDI Date: 03-18-15 Lic: 631515 : FS -165-02.1 I EQUIPMENT SCHEDULE 305XPA-IIOOAKEVR CRT. QTY DESCRIPTION MODEL # NO. "VIT' EEDER-ROOA.S.T. PROBE INS TALLATION 312020-984 1 1 12.000 GALLONS "MODERN WELDING" A.S.T. MODERN WELD/NG I "FIREGUARD' GASOLINE TANK 312020-928 "MODERN WELDING" GROUND LEVEL FILL I SYSTEM FOR E85 INCLUDES: 794390-420 3" OVERFILL PREVENTION VALVE 9095AA3300AVEVR I "BAKER' 20 GALLON TANK MOUNTED FILL 700-3B 1 SPILL CONTAINMENT BOX 790091-001 1 "MORRISON BROS." 3" VERTICAL CHECK 15BA-0800AV VALVE I "MORRISON BROS." 3" DRY BREAK FILL 927-0300AAEVR ADAPTOR "MORRISON BROS." 3" DUST CAP 735DC-4000ACEVR "MORRISON BROS." 3" VAPOR ADAPTOR 323-0400AAEVR "MORRISON BROS." 3" VAPOR CAP 323C-Of00ACEVR "FILL -RITE' HAND PUMP 151 "MODERN WELDING" GALVANIZED END LADDER MODTANK WITH STICKING PLATFORM TANK TRIM I "MORRISON" 8" EMERGENCY VENT FOR 2440M-0600AVEVR SECONDARY TANK - 8 OZ MALE THREAD I ..MORRISON" 8" EMERGENCY VENT FOR 2440M-0700AVEVR PRIMARY TANK - 16 OZ MALE THREAD 1 HUSKY PRESSURE VACUUM VENT 5885 1 "MORRISON BROS." Z' CLOCK GAUGE 818-OIOOAGEVR I F.E. PETRO 3 HP SUBMERSIBLE TURBINE STPAG75- VL2 PUMP - AG 1 F.E. PETRO SIPHON CARTRIDGE IT 400137937 1 F.E. PETRO SMART CONTROLLER WITH 402312921 ISOLATION BOX 1 F.E. PETRO MECHANICAL LEAK DETECTOR STP -MLD I F.E. PETRO LEAK DETECTOR TEE ADAPTOR 400518001 I .MORRISON BROS." Z' STAINLESS STEEL BALL 691BSS-08001V VALVE 1 FLEXING Z'X18MSX FLEX CONNECTOR FF20X18M346XF I ..MORRISON BROS." Z' SOLENOID VALVE 71OSS-2200 1V 120 VAC 1 "HEALY' MINI -JET WITH SIPHON 9000-02 f "HEALY' MONITOR SYSTEM, INCLUDES: 6280A 6280 MONITOR 6275 VENT SENSOR HPVVB VACUUM VENT VALVE SYSTEM MONITOR CONTROL BOX 9800-1 PRESSURE SWITCH HPV1.5 PRESSURE VENT VALVE (1) 9466 CHECK VALVE 1 "HEALY' WATER COLUMN GAUGE 939349A 1 "MORRISON BROS." CHECK VALVE 530-0100 AV I JOMAR J" BALL VALVE 100-701 1 JOMAR 1" BALL VALVE 100-705 "WAYNE" RELIANCE 1 HOSE SINGLE PRODUCT, 2 REMOTE MECHANICAL DISPENSER WITH f0:1 EIG320ID127ACJKIJVI PULSER, INTERNAL FILTER, AC JUNCTION BOX AND HOSE MATS - E85 COMPATIBLE 2 "HEALY' STANDARD GASOLINE HOSE 5' 75B-050-S2S2 2 "HEALY' STANDARD GASOLINE BREAKAWAY 8701VV 2 "HEALY' STANDARD GASOLINE HOSE 7' 75B-070-S2S2 2 "HEALY' 400 OVRV NOZZLE 400-04FS 2 UNIVERSAL HOSE ADAPTOR CX6-A 2 BRAVO ABOVEGROUND DISPENSER B -8600 -IPM 1 CONTAINMENT BOX OPW 1j" DOUBLE POPPET PRODUCT IMPACT 2 VALVE - E85 IOP -015E85 2 OPW VAPOR POPPETED PRODUCT IMPACT 60VSP-1001 VALVE 2 BRAVO Z' PENETRATION FPF-8600 4 FLEXING 1j"X18MSX2"F FLEX CONNECTOR FF15XIBHMXM346 2 BRAVO ELECTRICAL FITTING FEF -EBS 1 "VEEDER-ROOT' MONITORING CONSOLE WITH TLS -350 INTEGRAL PRINTER 1 "VEEDER-ROOT' FOUR INPUT PROBE MODULE 329356-002 1 "VEEDER-ROOT' EIGHT INPUT SENSOR 329358-001 MODULE I "VEEDER-ROOT' FOUR RELAY OUTPUT 329359-001 INTERFACE MODULE "VEEDER-ROOT' MAC PLUS PROBE FOR I ALTERNATIVE FLUIDS E85 W/0 WATER 846391-4XX DETECTION "VEEDER-ROOT' PROBE INSTALL IT - 1 ALTERNATE FLUID - E85 (NO WATER FLOAT) 846400-004 I "MORRISON BROS." PROBER RISER CAP 305XPA-IIOOAKEVR AND ADAPTOR I "VIT' EEDER-ROOA.S.T. PROBE INS TALLATION 312020-984 K I Z' INTERSTITIAL SENSOR 312020-928 CAPEDER-ROOT' I "VEEDER-ROOT' INTERSTITIAL SENSOR FOR 794390-420 STEEL TANK I "VEEDER-ROOT' PIPING SUMP SENSOR 794380-208 1 "VEEDER-ROOT' OVERFILL ALARM 790091-001 1 "VEEDER-ROOT' ACKNOWLEDGEMENT SWITCH 790095-001 FUEL MANAGEMENT SYSTEM I "FUELMASTER" FUEL MANAGEMENT CONTROL FMU-2500 PUNS UNIT "FUELMASTER' MODEM FOR PC "FUELMASTER' WINDOWS PLUS SOFTWARE FIRE E MINIMUM TYPICAL AT J ��� nnn.�an .vs nn. •a \ f ruo MENno IOWA[ENOS Iowa REVISIONS PETERSOP No. Description Date I By CAaMF SITE PLAN C) Sc.: r• = 40'-0" NORTH W NOTES AND LEGEND NOTE: ALL NOTES ARE TYPICAL ® SEE CIVIL FOR LAYOUT AND HORIZONTAL CONTROL - TYPIG OFF-SITE IP6°ROVEM NTS - SEE CIVIL CONCl;ETE CURB TYPICAL - SEE CIVIL ® CONCRETE PAVING - SEE CIVIL ASPHALT PAVING TYPICAL - SEE CIVIL CONCRETE WALKWAY / PATIO TYPICAL - SEE CIVIL NOTE- MAX 4M 2% CROSS SLOPE ON ALL WALKWAYS ® 3911 STRIPING - TYPICAL PARKING BUMPER - TYPICAL HC PACILITIES SIGN - ®1 ACCESSIBLE PARKB-46, LAYOUT 011 LANDSCAPINGAREA - SEE LANDSCAPE 012 MASONRY WALL VIR(Ar-.HT IRON PERSONNEL GATE 9i 9WR000HT IRON VEHicl-s GATE UJITFI POeER OPERATOR QCRAM LIW FENCING TRASH AND RECYCLE ENCLOSURE 12 GENERATOR ENCLOSURE I - I8 Fi19EE STORAGE CONTAINER ENCLOSURE ®g . MONUMENT SIGN ® FLAGPOLES 20 ®A FLAGPOLE BENCHES eABOVEGROUND RIEL TANK ® EMERGENCY GENERATOR - SEE ELEC ®CONCRETE PAD DESIGNATED FOR RENTAL GENERATOR ® WASTE OIL TANK ® RADIO VAULT ® COI111N:ICATIONS TOURER TRRNCATED DOME DETECTABLE WARNING VVVPER CBC W-1.558 ® CARPORT STRICTURE. ®IB COVERED SHADE PATIO ® RIEL ISLAND CANOPY ®3 MECHANICAL UNITS - SEE MECH 03 BICYCLE RACKS ®3 NOT USED NOT USED � 10 (033. MECHANICAL YARD ENCLOSURE Q!,•'-Il — — — — — — — — — I FUEL�TANX- 5'-0" 7'-0" 7'-0" 5'-0" ROOF LINE o ABOVE CONCRETE I v PAD I 4'-0" I MAX. "WAYNE FUEL DISPENSER 0 o 0 4 0I .�.:o . Io ;o L_1 I _ ..— * ,�":'r•c�: :1 CONCRETE TANK PAD 2" B.I., SCH 40 SINGLE I ABOVE CRUND DISPENSE CONTAINMENT "SBRAVO ' of 0 I AIR / WATER WALL -VAPOR RECOVERY PIPE ABOVEGROUND B-8600 h DISPENSER I o 2" B.I., SCH 40 SINGLE b' �I _0.. GALVANIZED LADDER MINIMUM I WALL -PRODUCT PIPE AND PLATFORM v ABOVEGROUND 1 r------------- — — —-- - - -- — — — — — -- — �.. COPPER I o I e"IPORT 0 CUBING I 0 CHEC I 4" �PPO0RT FOR 2" BALL TANK NCY VENT CONDENS I VALV I PH SE I VAPOR VALVEI T FOR SECOND RY I I " BA 1 RE OVERY 4" PORT FOR NK EMERGENCY VE X 4" PORT C ADAPTOR VALV SOLIN NO CA 1 1 1 I I MAG PROBE 6" PORT 2,000 C FO FILL . a 0 000 CAS o o XEALY 9 00 A E MINI JE PUM E GROU D I 2" MONITOR TANK SU9MERSIB I P I PORT FUEL SYSTEM f1NACEMENT "FUEL MASTER' I, F L TAN 20 CAL TANK " TANK 0 MOUNT SPI 1 ' 0 o 0 0 I o o "(OR ° o o ° —. —. — I 4" RT FOR S. 'V' SU MERSIBLE PUAIIP � _ Q m CONTAINMENT IND TRIS PORT FO I W /j700 ERIES AS PER DE WC. "FS -1 AIL 5-09.1" MEC ICAL CAUC I I SO NOID 2 PORT F SECONDARY VA VE TANK WOR VENT VAPOR RECOVER 1 24'1 MANWAY �" THER ADAPTOR NO CA RE F TPER ; UBING7 3" PORT FOR PRI ARY w I I CONDENSATE I WORKING VENT 0 3" GASOLINE PRODUCT (3 VAPO R RECOVERY) L SCH $0. B.I. PIPE — — — — — — —1— — — — — — — — — — — — — — ?.-0.. 2" B. L. SCH 40 SINGLE 2" B.I., SCH 40 SIN LE WALL -PRODUCT PIPE' 7' f0" WALL -VAPOR RECOVERY 23.4„ PIPE ABVECROUND ABOVEGROUND 7'_10• - IL A o 0 I ABODE GROUND I AIR / WATER DISPENSER I 0 FS -06.2 h j I DISPENSER CONTAINMENT "SBRAVO" B-8600 FIRE EXTINGUISHER MINIMUM 2-4, 20 B:C I TYPICAL AT EACH COLUMN A 0 0 10 0 I K�'2 0 0 0 I 0 "WAYNE" FUEL 6" DIAM PIPE BOLLARDS DISPENSER I I A DWG. "FS -165-'09 I" FS -06.1 ^• BY OTHERS O I c ROOF LINE ------ /ABOVE ------------J — NO E. IF DWG. IS NOT 24" X 18" IT IS NOT FULL SIZE ENLARGED FUEL TANK LAYOUT REVISIONS PETERSON HYDRAULICS INC. 1653 W. EL SEGUNDO BLVD., GARDENA, CA, 90249, ph:(310023.3155 No. Description Date B}/ CALIFORNIA HIGHWAY PATROL – FIELD AND DISPATCH OFFICE REPLACEMENT sc.: �" = 1'-0" NORTH ENLARGED FUEL TANK LAYOUT 9855 COMPAGNONI STREET, BAKERSFIELD, CALIFORNIA, 93313 z o Bate: AS NOTED Date: 03.18.15 L{c: 631515 .' FS -165-05.1 NOTE: FOR ALL TANK OPEN/NGS SEE "ENLARGED FUEL TANK LAYOUT' DRAWING "FS -165-05.1". "WAYNE" 6" DIAM PIPE BOLLARDS PER DETAIL "A" DWG. "FS -165-09.1" - BY OTHERS ABOVE GROUND DISPENSER CONTAINMENT "SBRAVO" B-8600 OILT.O.C., +0'-0" I ITTING u / FUEL STATION T.O.S.: +15'-O"rL FUEL TANK 5'-0" FITTING I r.;". SBRAVO' B-8600 3" PRIMARY TANK WORKING VENT, --2"-BAt L—y E SCH. 40, BLACK IRON I I ON PRODUCT PIPE - HEALY 9000 MINI JET PUMP 2" BALL VALVE zo G.A.LVANIZED LADDER SUBMERSIBLE (BEYOND) ON PRODUCT PIPE I AND PLATFORM PUMP (BEYOND) I I l'' 2" B.I., SCH 40 SINCE ' 2" B.I., SCH 40 SINGLE WALL -PRODUCT PIE RETE TAN WALL -PRODUCT PIPE iAB VEGROU D ABOVEGROUND i CONCRETE $- TUBING i" COPPER TUBING C NDENSA E PAD CONDENSATE i PAD 2" B.I., SCH 40 SINCE 2" B.L. SCH 40 SINGLE 1}" X 18" FLE LOWEST PO WALL-VAPO RECOVEfi Y LO WALL -VAPOR RECOVERY -- "X 18" FLEX PIPE AB VEGROU D II PIPE ABOVEGROUND .... CONNECTOR FOR V.R. P / II� I FOR V. R. PIPE CONNECTOR 3" VAPORI OVERY SCH 40, 1 / 1.CK PIPE \ I / 3" FILL PIPE I I \ j' :} SCH40, BLACK IRON III I "WAYNE' FUEL MINIMUM �•;ie: DISPENSER III w 12,000 LLONS 1 GASOLINE A OVEGROUND I T K HAND I I FIRE EXTINGUISHER 21 6 L TANK MOUNTED SPILL 3/i' CHECK I I PUMP I MINIMUM 2-A, 20 B.•C VALVE I I I TYPICAL AT EACH COLUMN CONT #7 0 BAKER INDUSTRIES" 31i LL E AS PER DETAIL "B" I I (BEYOND) I VAL DWG. "FS -165-09.1' � NOTE: IF DWG. IS NOT 24" X 18•' IT IS NOT FU L SIZE SECTION "A—A" i1 \ II VAPOR RECOVER VIEW REVISIONS ETERSON HYDRAULICS INC. 1653 W. EL SEGUNDO BLVD., GARDENA, CA. 90249, ph:(310)-323-3155 3" CHECK ADAPTOR AN I No. Description Date By CALIFORNIA -HIGHWAY PATROL - FIELD AND DISPATCH OFFICE REPLACEMENT Sc.: ;' = 1'-0' \ VALVE / _ TRANSVERSAL VIEW 1}" IMPA T SHUT-OFF 3" BALL VALVE 1}" IMPACT SHUT-OFF 7:;wo VALVE 0 PRODU LINE \ II / I VALVE ON PRODUCT LINE 3'-0" 3" KAMLOCK D ADAPTER W/ CAP I I � MINIMUM III / MINIMUM , ^ ' "BRAY 2" "BRAVO ABOVE GROUND NETRAT ON III PENETRATION ti`_z DISPENSER CONTAINMENT I ITTING u / FITTING I r.;". SBRAVO' B-8600 zo l'' I CON RETE TAN I CONCRETE PAD PAD 1}" X 18" FLE LOWEST PO NT I LO EST POINT -- "X 18" FLEX .... CONNECTOR FOR V.R. P PE FOR V. R. PIPE CONNECTOR :} { VERIFY MINIMUM �•;ie: ' NOTE: IF DWG. IS NOT 24" X 18•' IT IS NOT FU L SIZE SECTION "A—A" TRANSVERSAL VIEW REVISIONS ETERSON HYDRAULICS INC. 1653 W. EL SEGUNDO BLVD., GARDENA, CA. 90249, ph:(310)-323-3155 No. Description Date By CALIFORNIA -HIGHWAY PATROL - FIELD AND DISPATCH OFFICE REPLACEMENT Sc.: ;' = 1'-0' TRANSVERSAL VIEW 9855 COMPAGNONI STREET, BAKERSFIELD, CALIFORNIA, 93313 2 o tale: AS NOTEDI Date: 03-18-15 Lic: 631515 : F9165-06.1 NOTE: FOR ALL TANK OPENINGS SEE "ENLARGED FUEL TANK LAYOUT' DRAWING "FS -165-05.1". s 3" VAPOR RECOVERY SCH 40, BLACK PIPE 3" FILL PIPE SCH 40, BLACK IRON 3114'' CHECK VALVE HAND PUMP 3" BALL VALVE3" KAMLOCK ADAPTER W/ CAP 20 C iit ANK MOUNTED SPILL CO -`y MENT "BAKER INDUST {4'700 SERIES A _ ER DETAIL "B" "FS -165-09.1" VAPOR RECOVERY ADAPTOR AND CAP iw..... 7'_10.. YF, r- D F -C 14" V-0- 7'-0" SOLENOID VALVE FUEL (TANK VACUUMS. �( V. SWITCH SUBMERSIBLE i 2" PRODUCT i 1NP PE 4" PORT FOR 8" SECONDARY e MAGPR E CONTAINMENT CLOCK EMERGENCY VENT GAUGE 24" MAN OLE 8" PRIMARY TANK EMERGENCY VENT_ F jai n _ _ H n u lk 2" VAPOR RECOVERY 3" TUBING CON ENSAT P: V NT PI PE TO. SIPHON Po�i ISENSOR ON TURBINE �i OV.PRFILL n Pl'VENTION VALVE 3 DROP i i 9 SHUT-OFF TUBE i ii I ii I 11 I 3/," BALL i u ii o VALVE 12, 000ALLONS L3" CHECK I GASOLINE ABOVEGROUND VALVE .I TANK L3" CPAN SECTION "A—A" — LONGITUDINAL VIEW Sc.: J„ = 1'-0.. J11 _GALVANIZED LADDER AND PLATFORM 2" PRIMARY TANK WORKING VENT,SCH. 40, BLACK IRON 2" SECONDARY CONTAINMENT WORKING VENT 4" PORT SPARE ANNULAR _ SPACE 7'-10" FUEL MANAGEMENT SYSTEM "FUEL MASTER" G" DIAM PIPE BOLLARDS PER DETAIL "A" F-DWC. "FS -165-09.1" - BY OTHERS 2'-0" FILL AND CROWN WITH CONCRETE — BY OTHERS Nr 1, I�—STEEL PIPE, WITH YELLOW PROTECTIVE SLEEVE BY OTHERS CONCRETE SLAB 18" DIA. CONCRETE FOOTING Tank Fill Optional secondary opeining 2'--3'pipe site / typically for vapor recovery connection . T L --'— I T 191V 19' I'FPF for I11A manual pump out 3/8'•16x 1'stufor tound connection 9y,' O 2'typ t Lock Tab 2615' OIL:= i l S5' R,ndsnN Con6hiloUsIV sloped bottom to 3' "mit, with TS'FPT drain 6 plug t l 1 1 - : "i'J. MF�lli��7�lf�•�II�� • ZIM94l•FIIl71F7 MEETS2OI21BC-^ Li1�.T1LL�L}7 izly..M E—V9N R17—M F I ----------------- r , ttA•71�� -A�—KI—Mr-0 1A. • r l INNER TANK: PER J.L. G CONIAINMENI PROIECTED OUTER TANK: PER J.L. I F ABCVEGROUNDTANK. 1/4'HOLES I I E I AIEST EC01". INTERIOR: BARE CLEAN OF io D •. DF.BP•IS O ® 000 0 O O SECOHDARY EXTERIOR: WHITEHISSIDEWrTH 18" CONCRETE SLAB 18" DIA. CONCRETE FOOTING Tank Fill Optional secondary opeining 2'--3'pipe site / typically for vapor recovery connection . T L --'— I T 191V 19' I'FPF for I11A manual pump out 3/8'•16x 1'stufor tound connection 9y,' O 2'typ t Lock Tab 2615' OIL:= i l S5' R,ndsnN Con6hiloUsIV sloped bottom to 3' "mit, with TS'FPT drain 6 plug �. -i rollovnng any model no. designates stainless steel construction. - Cutout and bait holes predrilled for T UL Listed flexible entry boot (supplied I with unit). IDA' I ITwet Not; To 3 fdh ryykq 1 am —Tank moutft bracket with e/I8'dl8 boa holo, Iyp. S pIM 2' #700 SERIES GROUND LEVEL SPILL CONTAINMENT TANK MOUNTING BRACKT MODELS BAKER INDUSTRIES NORTHWEST REV 12428 Highway 99 South, Unit 56 REV Everett, Washington 98204-5502mn Tel:(425)212.3169 • FAX:(425)353-8788 • e-mail; lae®nw. bakerindcom REV iwrw.ba kerindushiesnonhwestoom MATERIALS: • SPILL CONTAINMENT CABINET: 16GA STEEL MINIMUM (ALT'S' 16GA MINIMUM —STAINLESS STEEL) • MOUNTING BRACKETS: %'X 2 STEEL FLAT BAR (ALT'S' S/S SCH 40 MIN) • FILL AND DRAIN PIPE FITTINGS: ALL STEEL. SCH 40 MIN (ALT'S' SIS SCH 40 MIN) • LOCK TABS: 3118' STEEL WITH %'OIA PADLOCK HOLE (ALT •S- 3116' STAINLESS STEEL) COATING: POWOERCOATEPDXY FINISH INTERIOR AND EXTERIOR(ALT-S'BARE STAINLESS STEEL, NO COATING) CAUTION FLAMMABLE OR COLISUSTISLE L 11.115 rAPORS MAV SR PTRIES. . KEEP A—v A'_6 FUME, IGNlf1ON SOURCES. ExSINOUITIN SMOKING MATERIALS. FOR USE wRN PROPERLY VENTED STORAGE VESSELa, KEEP DOOR CLOSED AMD LACKED MEM NOT IN LRE This drawing and design are proprietary to BAKER INDUSTRIES NORTHWEST, and may not be copied or duplicated In whole or in part without the written permission of BAKER INDUSTRIES MIN. DRAWN CHECKED DATE LRG RBW 03.28.95 SLG LRG 03-05-06 BOLLARD DETAIL:I I N.T.S.700 SERIES GROUND LEVEL SPILL CONTAINMENT. I LJD SCALE: J" = 1'-0" SCALE: MEETS 2013 CBC t l 1 1 - : "i'J. MF�lli��7�lf�•�II�� • ZIM94l•FIIl71F7 MEETS2OI21BC-^ Li1�.T1LL�L}7 izly..M E—V9N R17—M F I ----------------- r , ttA•71�� -A�—KI—Mr-0 1A. • r l �. -i rollovnng any model no. designates stainless steel construction. - Cutout and bait holes predrilled for T UL Listed flexible entry boot (supplied I with unit). IDA' I ITwet Not; To 3 fdh ryykq 1 am —Tank moutft bracket with e/I8'dl8 boa holo, Iyp. S pIM 2' #700 SERIES GROUND LEVEL SPILL CONTAINMENT TANK MOUNTING BRACKT MODELS BAKER INDUSTRIES NORTHWEST REV 12428 Highway 99 South, Unit 56 REV Everett, Washington 98204-5502mn Tel:(425)212.3169 • FAX:(425)353-8788 • e-mail; lae®nw. bakerindcom REV iwrw.ba kerindushiesnonhwestoom MATERIALS: • SPILL CONTAINMENT CABINET: 16GA STEEL MINIMUM (ALT'S' 16GA MINIMUM —STAINLESS STEEL) • MOUNTING BRACKETS: %'X 2 STEEL FLAT BAR (ALT'S' S/S SCH 40 MIN) • FILL AND DRAIN PIPE FITTINGS: ALL STEEL. SCH 40 MIN (ALT'S' SIS SCH 40 MIN) • LOCK TABS: 3118' STEEL WITH %'OIA PADLOCK HOLE (ALT •S- 3116' STAINLESS STEEL) COATING: POWOERCOATEPDXY FINISH INTERIOR AND EXTERIOR(ALT-S'BARE STAINLESS STEEL, NO COATING) CAUTION FLAMMABLE OR COLISUSTISLE L 11.115 rAPORS MAV SR PTRIES. . KEEP A—v A'_6 FUME, IGNlf1ON SOURCES. ExSINOUITIN SMOKING MATERIALS. FOR USE wRN PROPERLY VENTED STORAGE VESSELa, KEEP DOOR CLOSED AMD LACKED MEM NOT IN LRE This drawing and design are proprietary to BAKER INDUSTRIES NORTHWEST, and may not be copied or duplicated In whole or in part without the written permission of BAKER INDUSTRIES MIN. DRAWN CHECKED DATE LRG RBW 03.28.95 SLG LRG 03-05-06 BOLLARD DETAIL:I I N.T.S.700 SERIES GROUND LEVEL SPILL CONTAINMENT. I LJD SCALE: J" = 1'-0" SCALE: MEETS 2013 CBC GA vAN1'e 1.IATERU.L AND CONST. CONFORM MEETS2OI21BC-^ [4 ANDPI.AiFORM ERV0.1 ----------------- r , H LABORATORIES STANDARD U.L.-1. SECONDARY INNER TANK: PER J.L. G CONIAINMENI PROIECTED OUTER TANK: PER J.L. I F ABCVEGROUNDTANK. 1/4'HOLES I I E I AIEST EC01". INTERIOR: BARE CLEAN OF I D III. LA EL FOR PROTECT= DF.BP•IS O ® 000 0 O O SECOHDARY EXTERIOR: WHITEHISSIDEWrTH I I COPItAa4MENT POLYURETHANE I RBv10VEA8LE CHAINS IN PLACE OF RAILING ALCVEGROLIND TANK REOJIRED. SIZE O.D. LENGTH I I t�A QrY S17.0 n'Pn RESFARKR12,000 CARE EXECUTIVE ORDER 33,000#SCHrDUI.r L— ----------J Or OPENING! VR -502 C. I I KID 18' IB' 18TV ,000NNECTING 3(r 18' le" ie' C6'P IN75. 18' w ® CRETHA 6P I. PRI I NDi FSS i O BE TESTED ALONE. / \ APP OX.,_ µ nl APP 3' SPSI. PRIMARYl KTOIl 6E tFKSUR AIONE. 11' 10" I 3' SECOFU NPRW Y LENRESSURE L BE VInFI PRESSJRE INPRWARY TANK. THa "ALL6F AIBYFA:IED PY 7 EEW+G ADA FROM tNE w.rsr u� f'�i� I•u i PRIMK AIM MOINESECONDARY IANK AT NO TIME SHALL THE PRESSURE IN THE SECONDARY TANK EXCEED THE �`—moi •,��_------- FRESSL'RE IN THE PR;MARY TANK. L ------- •_6'• •_g• I'w•"�' ONE O) IRFN Nm FC 12000 ® modaii Adaig company of (;Iffi* inc, Pre � P.M.E. 12000 GAhIAN 010DIiR.\ FIRF•.GIIARD'I'r1KI: California Highway Patrol BAKERSFIELD, CA 4c DD, vl:nse NOK, n ID4u JA Ran — on 1_v_ I 12.000 GALLON TANK LAYOUT: SCALE: NTS. 9000 SERIES MINI—JET CENTRAL VACUUM SOURCE DETAIL: T1 SCALE. N.T.S. 0 DWG. IS 0 2 8" IS 0 FULL SIZE lJ REVISIONS PETERSON HYDRAULICS INC. 1653 W. EL SEGUNDO BLVD., GARDENA, CA, 90249, ph:(310)-323J755 IN0.1 Description I Date I HH I CALIFORNIA HIGHWAY PATROL — FIELD AND DISPATCH OFFICE REPLACEMENT C' I 9855 COMPAGNONI STREET, BAKERSFIELD, CALIFORNIA, 93313 BY: zCoTScd2e: AS NOTEDI Date: 03-18-15 LI ___ K I 1 4" 1 FNPT 135y. i 1 I 7' MNPT MONnOR H 1 1 4" 1 FNPT I G 1 1 4" 1 -NFT F 1 4.' FNPT 1/4'HOLES E 1 8' FNFi SCLONDARY Ely; BASE PLATE DETAIL D I B' FNFT .1 PERSALCFFOUR PER SADDLE I 4" FNFi I X FNPT I 6" FNPT Fill 77 SIZE O.D. LENGTH WEIGHT t�A QrY S17.0 n'Pn RESFARKR12,000 121' 23'-4" 33,000#SCHrDUI.r Or OPENING! 12.000 GALLON TANK LAYOUT: SCALE: NTS. 9000 SERIES MINI—JET CENTRAL VACUUM SOURCE DETAIL: T1 SCALE. N.T.S. 0 DWG. IS 0 2 8" IS 0 FULL SIZE lJ REVISIONS PETERSON HYDRAULICS INC. 1653 W. EL SEGUNDO BLVD., GARDENA, CA, 90249, ph:(310)-323J755 IN0.1 Description I Date I HH I CALIFORNIA HIGHWAY PATROL — FIELD AND DISPATCH OFFICE REPLACEMENT C' I 9855 COMPAGNONI STREET, BAKERSFIELD, CALIFORNIA, 93313 BY: zCoTScd2e: AS NOTEDI Date: 03-18-15 LI ___ "WAYNE' ELECTRONIC FUEL DISPENSER VALVE "BRAVO" ABOVEGROUND STEEL DISPENSER CONTAINMENT fj" X 18" F EX CONNEC OR Z' B.L. SCH 40 SINGLE WALL -VAPOR RECOVERY PIPE ABOVEGROUND AUTOMATIC NOZZLE DIESEL Z' "BRAVO" PENETRATION FITTING BREAKAWAY VALVE VAPOR RECOVERY FUEL HOSE Z' B.I., SCH 40 SINGLE WALL -PRODUCT PIPE ABOVEGROUND CONCRETE TANK %PAD ♦y w . SECTION "A -A" - DISPENSER FRONT VIEW: I A A SCALE: 1" = f'-0". REVISIONS rETERSON HYDRAULICS INC. 1653 W. EL SEGUNDO BLVD., GARDENA, CA, 90249, ph:(310)-323J155 No. Desc+ ptian Date By CALIFORNIA HIGHWAY PATROL - FIELD AND DISPATCH OFFICE REPLACEMENT FUEL SYSTEM DETAILS 9855 COMPAGNONI STREET, BAKERSFIELD, CALIFORNIA, 93313 ELECTRIC AREA CLASSIFICATION sc.: i,. = 1'-0" AREAS WITHIN THE ENCLOSURE WHERE VAPOR OR LIQUID IS PRESENT UNDER NORMAL OPERATING CONDITION CONCRETE 20,-0" j NO'. No NORTH ALL VENTS, PIPING, STEEL ANGLES, ELECTRICAL, STRUCTURAL, DRAIN, CONCRETE WORK AND EQUIPMENT NOT PART OF 'PETERSON HYDRAULICS, INC." SCOPE OF WORK SHOWN ON THIS DRAWING ARE SHOWN FOR COORDINATION ONLY AND ARE NOT TO BE CONSIDERED AS PART OF THE EQUIPMENT BEING PROVIDED. OALL CONDUITS ENTERING AND LEAVING THE CLASSIFIED/HAZARDOUS AREAS SHALL HAVE SEAL -OFFS PER N.E.C. 501.5 (A) OTYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (ABOVEGROUND TANK) EXTENT OF CLASS 1 DIVISION 2 LOCATION. WITHIN 18 INCHES HORIZONTALLY IN ALL DIRECTIONS EXTENDING TO GRADE FROM (1) THE ABOVEGROUND TANK OR, (2) THAT PORTION OF THE ABOVEGROUND TANK ENCLOSURE CONTAINING LIQUID HANDLING COMPONENTS. OC TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - DISPENSER) EXTENT OF CLASS 1 DIVISION 2 LOCATION.• WITHIN 18 INCHES HORIZONTALLY IN ALL DIRECTIONS EXTENDING TO GRADE FROM (1) THE DISPENSER ENCLOSURE OR, (2) THAT PORTION OF THE DISPENSER ENCLOSURE ENCLOSURE CONTAINING LIQUID HANDLING COMPONENTS. OD TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - OUTDOOR) EXTENT OF CLASS 1 DIVISION 2 LOCATION: UP TO 18 INCHES ABOVE GRADE LEVEL WITHIN 20 FEET HORIZONTALLY OF ANY EDGE OF ENCLOSURE. TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - DISPENSER) EXTENT OF CLASS 1 DIVISION 2 LOCATION. SPACE CLASSIFICATION INSIDE THE DISPENSER ENCLOSURE 1N COVERED IN ANSI/UL87, "POWER OPERATED DISPENSING DEVICE FOR PETROLEUM PRODUCTS." DISPENSER j c 18' REVISIONS IPETERSON HYDRAULICS INC. 1653 W. EL SEGUNDO BLVD., GARDENA. CA 90249, ph:(310)-3233155 Description Date I By I CALIFORNIA HICHWAY PATROL - FIELD AND DISPATCH OFFICE REPLACEMENT 9855 COMPAGNONI STREET, BAKERSFIELD, CALIFORNIA 93313 T RED LETTERS - - _ 'EMERGENCY SHUT . OFF SWITCH' SIGN VEEDER ROOT OOVERFILL ALARM Pr RICID CONDUIT I • I EMERGENCY SHUT m VEEDER ROOT OD OFF SWITCH, ' - ACKNOWLEDGMENT SWITCH p C I Q. SEAL OFP Q 4'°" SEAL OFF k k m � REMOTE OVERFILL ALARM AND ACKNOWLEDGMENT SWITCH: - . EMERGENCY SHUT-OFF DETAIL: D 1� SCALE: 3'i• = 1'-0" SCALE: 3'i• = 1'-0" S„ ALL VENTS, PIPING, STEEL ANGLES, ELECTRICAL, 12,000GASOLINE FUEL TANK STRUCTURAL, STRUCTURAL, DRAIN, CONCRETE WORK AND #1/0 COPPER EOUIPMENT NOT PART OF "PETERSON GROUND TANK CONCRETE HYDRAULICS, INC." SCOPE OF WORK SHOWN ON PAD THIS DRAWING ARE SHOWN FOR COORDINATION a : ONLY AND ARE NOT TO BE CONSIDERED AS Q . P° ° " a PART OF THE EQUIPMENT BEING PROVIDED. ° .. Q.. 10 FT LONG X 3/i' DIA. y COPPER CLAD STEEL GROUND ROD NOTE: IF DWG. IS NOT 24" X 16", IT IS NOT FULL SIZE REVISIONS ETERSON HYDRAULICS INC. 1653 W. EL SEGUNDO BLVD., GARDENA, CA, 90249, ph:(310)-323.3155 No. Desmpt" Dae I By I CALIFORNIA HIGHWAY PATROL — FIELD AND DISPATCH OFFICE REPLACEMENT ELECTRICAL DETAILS 9855 COMPAGNONI STREET, BAKERSFIELD, CALIFORNIA, 93313 GROUND ROD DETAIL: r SCALE. N.T.S. M. LCLSZLO[ScaLe: AS NOTED1 Date: 03-18-15 Lic: 631515 : E-165-09.1 SENSORS — BY OTHERS LOW VOLTAGE CONDUIT DETAIL: I A SCALE: N.T.S. ALL VENTS, PIPING, STEEL ANGLES, ELECTRICAL, STRUCTURAL, DRAIN, CONCRETE WORK AND EQUIPMENT NOT PART OF 'PETERSON HYDRAULICS, INC." SCOPE OF WORK SHOWN ON THIS DRAWING ARE SHOWN FOR COORDINATION ONLY AND ARE NOT TO BE CONSIDERED AS PART OF THE EQUIPMENT BEING PROVIDED. REVISIONS IPETERSON HYDRAULICS INC. 1653 W. EL SEGUNDO BLVD., GARDENA, CA, 90249, ph:(310).323.3155 Description Date By CALIFORNIA H/OHIIAY PATROL — FIELD AND DISPATCH OFFICE REPLACEMENT ELECTRICAL DETAILS 9855 COMPAGNONI STREET, BAKERSFIELD, CALIFORNA 93313 z cafe: AS NOTED1 Date: 03-18-15 Lic: 631515 ' E-165-09.2 d S ,�Stanfilarrld Models, FORM NO. _ r DESCRIPTION;_, . " 790091-001 Overfill Alarm' 790095-001 Alarm Acknowledgement Switch f iConsole CoittpafiHility� t 'NOTE. An 1/0 Combination Module (Form No. 329360-001) ora Four -Relay Output Module (Form N6 329359-001) is iegwred for; use of; th-0 Overfill Alarm and Alarm Acknowledge» rent Switch with.the TLS -350 or TLS=350R system: - 1 'DIMENSIONS 'Overfill Alarm s.000" - • 152.4 mm— 0,3,13Ff 4 Holes r a 10.750" 10;310", I II 273,1 mkii, F 261.9 mm" I 40.6 mm - � . 2,000;1 o''I o I Il 1/2' Conduit ` 50,8 mm. r _ Connector r �— r 4.000' y ,101.6mm Bottom View' Front View without Door iii Piece Side View " ,. Y Aiarm Ack' 6611 iigement Switch ' ',es.e mT /!)iolor . � a"�7fl2mm • IF � 1 Capnwwr I.. e71e"'. mo I I J leosn:m: iltsnal. I j` IIS �91U J A$ Bottom View Front View without. Door in Piece Side View - ,.,. VEEDER-ROOT ■:a Environmental • No, f the Leader in Tank Monitoring Technolcgy 125 Powder Forest dove, Poet Office Box 2003, Simsbury„ CT 06070.2003 TEL: (203) 651-_2700, FAX: (203) 651-2719 TECH SUPPORT: (203) 651 2753 BRAZIL: Sao Paulo. CANADA: Misilssauga Onleiio :, ENGLAND: Richmond Surrey - FRANCE: Rungis Cedex -GERMANY., Neuhausaf09 der PMfed 12848 replaces 12594 APB USA• 94- i ' TLS -350R' TLS -350' . •TLS -300 TLS -300i 'TLS -250 TLS -250i ' Series -8482 Series 8470 Series 8485 Series 8485' Series�71341 Series 7949