HomeMy WebLinkAboutHAZ WASTE SQG 10/23/2017HAZARDOUS WASTE
BAKERSFIELD FIRE DEPARTMENT
UNIFIED PROGRAM CONSOLIDATED FORMS Prevention Services
. .. E R ..a F L. ....._p 2101 H Street
FINE
SMALL QUANTITY HAZARDOUS ARrM T ..Bakersfield, CA 93301
WASTE GENERATOR INSPECTION Phone:661- 326 -3979 • Fax: 661- 852 -2171
Facility Name: ?,� Date: s s
Site Address: `' ? L -� (, :•:r ; >' c Time In: Time Out:
Owner /Operator: Phone: EPA ID #
Type of Inspection
0 Routine 0 Re- inspection/Follow -up 0 Combined Routine Inspection 0 Joint Inspection 0 Complaint 0 Focused 0 Other
0 CONSENT TO INSPECT GRANTED BY (Name / Title):
Inspection may involve obtaining photographs, review and copying of records, and determination of compliance with hazardous waste handling requirements.
!'� - /'�`.._,..- t......�. AT _ !'+7...,., T TT -- A/F. -..- A74..1.,+-
C
V .
HAZARDOUS WASTE REQUIREMENT
N/A
CER5
Violation #
COMMENTS
Recordkee in documentation
.
Generator has an EPA ID number [HSC 25143.131
3010002
'
Hazardous waste determination made for all wastes
0 Analysis ;[Generator Knowledge [CCR 66262.401
3030005
-�
Contingency plan information posted near phone [CCR 66262.34(d)(2)]
3010022
Facility personnel demonstrate training /awareness [CCR 66262.34(d)(2)]
3020001
Manifests /Consolidated Manifest receipts complete [CCR 66262.23(x)]
3010008
r :
Blue c'opy(s) of manifest mailed toDTSC [CCR 66262.23(a)(4)]
Bills of Ladin recei ts. available [CCR 66262.40(a)]
3010011
3010010
` F`
} -�
LDRs available and com lete [CCR 66268.7(a)]
3030006
Onsite recycling reported using UPCF [HSC 25143.10]
c:,
3030001
Container /tank management
h
Containers, are in good condition [CCR 66262.34(d)(2)]
3030013
Containers are closed except when adding/removing [CCR66262.34(d)(2)]
3030017
.''
Satellite containers at or near point of generation [CCR 66262.34(e)(1)(A)]
x�a
Empty containers are empty [CCR 66262.34(f)]
3030007
Containers inspected weekly [CCR 66262.34(d)(2)]
3030019
Tanks inspected daily [CCR 66262.34(d)(2), 40CFR 265.201]
" '
3030027
One container per waste stream at satellite area [CCR 66262.34(d)(2)]
3030022
Exclude recyclable materials stored in accordance with local
ordinance/hazardous materials codes [HSC 25143.101
3010016
Accumulation Time Limits
Waste is accumulated not more than 90 /180/270 [CCR 66262.34(d)]
3030010
,ns
Empty containers managed within one year [CCR 66262.34(d)]
3030010
Universal waste accumulated less than one year [CCR 66273.15(a)]
3030011
Used oil filters offsite within 1.80 (1 year <1 ton) [CCR 66266.130(c)(4)]
' %
3030004
Pb -acid batteries offsite within 180 (1 yr. < 1 ton) [CCR66266.81(a)(3)]
`" =
3030002
Labeling/Marking
-
Containers are properly labeled [66262.34(f)]
3030007
A 4
Excluded recyclable materials marked properly [HSC 25143.9(x)]
3050005
Universal waste container properly labeled (CCR 66273.341
3030008
Used oil filters marked "drained used oil filters" [CCR 66266.1301
3030004
Date written on spent lead -acid batteries [CCR 66266.81(a)(6)(B)]
3030003
"Used Oil" marked on all used oil tanks /containers [CCR 66279.21(b)]`
":
3030007
Tank marked with "haz waste" , contents, start date [66262.34(f)]
3030007
Treatment, Transport and Disposal/Other
Have permit/authorization to do treatment [HSC 25136.21
'°
3040003
Waste sent with authorized transport (gen. eligible) [CCR 66263.411
`}
3050001
Waste disposed of to authorized point/ party [HSC 25189.5(a)]
3050002
Failed to properly handle a fiance wastes [HSC 25212(a)]=
}
FireProtection _ [66262.34(d)(2)]
3030032
Print and sign in this box for receipt of this report. Signature does not imply agreement with findings only receipt of report.
_ r
S Y
INSPECTOR
POST INSPECTION INSTRUCTIONS:
• Correct the violation(s) noted above by
• Within 5 days of correcting all of the violations, sign and return a copy of this page to:
Bakersfield Fire_Dept., Prevention Services, 2101 H St. Bakersfield, CA 93301
White - Business Copy Yellow— Station Copy
Signature (that all violations have been corrected as noted)
Date
Pink- Prevention Services Copy
FD2171 (Rev 9/14)