Loading...
HomeMy WebLinkAboutFMC 2017MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of CaliforniaAuthority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. A.General Information Facility Name:Bldg. No.: Site Address:City:Zip: Facility Contact Person: Contact Phone No.: Make/Model of Monitoring System:Date of Testing/Servicing: B.Inventory of Equipment Tested/Certified Check the appropriate boxes to indicate specific equipment inspected/serviced: Tank ID:Tank ID: In-Tank Gauging Probe.Model:In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model:Annular Space or Vault Sensor.Model: Piping Sump / Trench Sensor(s).Model:Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model:Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model:Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Electronic LineLeak Detector.Model: Tank Overfill / High-Level Sensor.Model:Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2).Other (specify equipment type and model in Section E on Page 2). Tank ID:Tank ID: In-Tank Gauging Probe.Model:In-Tank Gauging Probe.Model: Annular Space or Vault Sensor.Model:Annular Space or Vault Sensor.Model: Piping Sump / TrenchSensor(s).Model:Piping Sump / Trench Sensor(s).Model: Fill Sump Sensor(s).Model:Fill Sump Sensor(s).Model: Mechanical Line Leak Detector.Model:Mechanical Line Leak Detector.Model: Electronic Line Leak Detector.Model:Electronic Line Leak Detector.Model: Tank Overfill / High-Level Sensor.Model:Tank Overfill / High-Level Sensor.Model: Other (specify equipment type and model in Section E on Page 2).Other (specify equipment type and model in Section E on Page 2). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). Dispenser ID:Dispenser ID: Dispenser Containment Sensor(s).Model:Dispenser Containment Sensor(s).Model: Shear Valve(s).Shear Valve(s). Dispenser Containment Float(s) and Chain(s).Dispenser Containment Float(s) and Chain(s). *If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C.Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers’ guidelines. Attached to this Certification is information (e.g. manufacturers' checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report;(check all that apply):System set-up Alarm history report Technician Name (print):Signature: Certification No.:License. No.:804904 Testing Company Name:Confidence UST Services, Inc.Phone No.:(800)339-9930 Site Address:Date of Testing/Servicing: Page 1 of 3 #3366/Fastrip#640(West) 8001WhiteLaneBakersfield93309 OmeroGarcia (661)393-7000 Veeder-RootTLS-350 07/12/2017 12,000gal.Regular1 847390-107 794390-420 794380-208 794380-208 FX1V 847390-107 12,000gal.Regular2(Siphon) 847390-107 794390-420 794380-208 794380-208 847390-107 12,000gal.Super 847390-107 794390-420 794380-208 794380-208 FX1V 847390-107 12,000gal.Diesel 847390-107 794390-420 794380-208 794380-208 FX1DV 847390-107 1-2 794380-208 3-4 794380-208 5-6 794380-208 794380-208 7-8 9-10 794380-208 11-12 794380-208 AaronPerrigo B47853 8001WhiteLane Bakersfield,CA93309 07/12/2017 794380-208 794380-208 794380-208 794380-208 Monitoring System Certification D.Results of Testing/Servicing Software Version Installed: Complete the following checklist: Yes No*Isthe audible alarm operational? Yes No*Is the visual alarm operational? Yes No*Were all sensors visually inspected, functionally tested, and confirmed operational? Yes No*Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* N/A If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) operational? Yes No* N/A For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) Sump/Trench Sensors; Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor failure/disconnection? Yes; No. Yes No* N/A For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent oftank capacity does the alarm trigger? % Yes*NoWas any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes*NoWas liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) Product; Water. If yes, describe causes in Section E, below. Yes No*Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable Yes No*Is all monitoring equipment operational per manufacturer’s specifications? * In Section E below, describe how and when these deficiencies were or will be corrected. E.Comments: Page 2 of 3 330.01 90 Monitoring System Certification F.In-Tank Gauging / SIR Equipment: Check this box if tank gauging is used only for inventory control. Check this box if no tank gauging or SIR equipment is installed. This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: Yes No*Has all input wiring been inspected for proper entry and termination, including testing for ground faults? Yes No*Were all tank gauging probes visually inspected for damage and residue buildup? Yes No*Was accuracy of system product level readings tested? Yes No*Was accuracy of system water level readings tested? Yes No*Were all probes reinstalled properly? Yes No*Were all items on the equipment manufacturer’s maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. G.Line Leak Detectors (LLD):Check this box if LLDs are not installed. Complete the following checklist: Yes No* N/A For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? (Check all that apply)Simulated leak rate: 3 g.p.h.; 0.1 g.p.h ; 0.2 g.p.h. Yes No*Were all LLDs confirmed operational and accurate within regulatory requirements? Yes No*Was the testing apparatus properly calibrated? Yes No* N/A For mechanical LLDs, does the LLD restrict product flow if it detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? Yes No* N/A For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? Yes No* N/A For electronic LLDs, have all accessible wiring connections been visually inspected? Yes No*Were all items on the equipment manufacturer’s maintenance checklist completed? * In the Section H, below, describe how and when these deficiencies were or will be corrected. H.Comments: Page 3 of 3 Leak Detector Test Results Sheet Customer Address: Work Order: Site Address: Test Date: Site Contact: Phone: Technician: Phone: 800-339-9930 ICC No.: Product Type LLD Type Model Serial No. Check Valve Holding Pressure Bleed Off ML. Leak Rate Tested: Pass/Fail 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi Technician Name: Technician No.: Signature: Date: JacoHill P.O.Box82515 Bakersfield,CA93380-2515 39358 07/12/2017 8485827-UT Regular1&2 Mechanical FX1V AaronPerrigo (661)393-7000OmeroGarcia Bakersfield,CA93309 8001WhiteLane #3366/Fastrip#640(West) 12 psi Pass FX1VMechanicalPremium 10 psi Pass FX1DVMechanicalDiesel 10 psi Pass AaronPerrigo 8485827-UT 07/12/2017 Jaco 3366 Setup 7-12-17 Responses Received: 200 FASTRIP 366 8001 WHITE LN BAKERSFIELD CA JUL 12, 2017 9:35 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 6969 67.63 1.0 86.1 5031 2 UNLEADED 2 7178 69.29 0.0 86.0 4822 3 PREMIUM 5473 55.85 0.0 85.8 6527 4 DIESEL 3009 35.84 0.9 90.5 8991 I90500 JUL 12, 2017 9:35 AM SOFTWARE REVISION LEVEL VERSION 330.01 SOFTWARE# 346330-100-B CREATED - 10.07.23.17.25 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I50500 JUL 12, 2017 9:35 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 JUL 12, 2017 9:35 AM SHIFT TIME 1 : DISABLED I50202 JUL 12, 2017 9:35 AM SHIFT TIME 2 : DISABLED I50203 JUL 12, 2017 9:35 AM SHIFT TIME 3 : DISABLED I50204 JUL 12, 2017 9:35 AM SHIFT TIME 4 : DISABLED I54600 JUL 12, 2017 9:35 AM TANK PER TST NEEDED WRN: DISABLED I54900 JUL 12, 2017 9:35 AM TANK ANN TST NEEDED WRN: DISABLED I55300 JUL 12, 2017 9:35 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 JUL 12, 2017 9:35 AM LINE PER TST NEEDED WRN: DISABLED I55900 JUL 12, 2017 9:35 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 JUL 12, 2017 9:35 AM PRINT TC VOLUMES ENABLED I50E00 JUL 12, 2017 9:35 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 JUL 12, 2017 9:35 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 JUL 12, 2017 9:35 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 JUL 12, 2017 9:35 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 JUL 12, 2017 9:35 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 JUL 12, 2017 9:35 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 JUL 12, 2017 9:35 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 JUL 12, 2017 9:35 AM TANK CHART SECURITY DISABLED I5BD00 JUL 12, 2017 9:35 AM CUSTOM ALARM LABELS DISABLED I56000 JUL 12, 2017 9:35 AM MASS/DENSITY DISABLED I88101 JUL 12, 2017 9:35 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 JUL 12, 2017 9:35 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 JUL 12, 2017 9:35 AM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88104 JUL 12, 2017 9:35 AM I88105 JUL 12, 2017 9:35 AM I88106 JUL 12, 2017 9:35 AM I52000 JUL 12, 2017 9:35 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE FEB 23, 2012 DISABLED 2 ON DATE FEB 23, 2012 DISABLED 3 ON DATE FEB 23, 2012 DISABLED 4 ON DATE FEB 23, 2012 DISABLED 5 ON DATE FEB 23, 2012 DISABLED 6 ON DATE FEB 23, 2012 DISABLED 7 ON DATE FEB 23, 2012 DISABLED 8 ON DATE FEB 23, 2012 DISABLED I60100 JUL 12, 2017 9:35 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 UNLEADED 2 ON 3 PREMIUM ON 4 DIESEL ON I60200 JUL 12, 2017 9:35 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 UNLEADED 2 3 PREMIUM 4 DIESEL I60300 JUL 12, 2017 9:35 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 UNLEADED 2 2 3 PREMIUM 3 4 DIESEL 4 I60900 JUL 12, 2017 9:35 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 UNLEADED 2 0.000700 3 PREMIUM 0.000700 4 DIESEL 0.000450 I60700 JUL 12, 2017 9:35 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 120.00 2 UNLEADED 2 120.00 3 PREMIUM 120.00 4 DIESEL 120.00 I60A00 JUL 12, 2017 9:35 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 1 PT 12000 2 UNLEADED 2 1 PT 12000 3 PREMIUM 1 PT 12000 4 DIESEL 1 PT 12000 I60400 JUL 12, 2017 9:35 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 12000 2 UNLEADED 2 12000 3 PREMIUM 12000 4 DIESEL 12000 I60500 JUL 12, 2017 9:35 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12000 0 0 0 2 UNLEADED 2 12000 0 0 0 3 PREMIUM 12000 0 0 0 4 DIESEL 12000 0 0 0 I60600 JUL 12, 2017 9:35 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 UNLEADED 2 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PREMIUM 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 DIESEL 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 JUL 12, 2017 9:35 AM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 UNLEADED 2 NO 3 PREMIUM NO 4 DIESEL NO I62F00 JUL 12, 2017 9:35 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 4.0 IN. 2 UNLEADED 2 4.0 IN. 3 PREMIUM 4.0 IN. 4 DIESEL 4.0 IN. I62700 JUL 12, 2017 9:35 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 UNLEADED 2 2.0 3 PREMIUM 2.0 4 DIESEL 2.0 9999FF1B I62400 JUL 12, 2017 9:35 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 UNLEADED 2 3.0 3 PREMIUM 3.0 4 DIESEL 3.0 I62800 JUL 12, 2017 9:35 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 12000 2 UNLEADED 2 12000 3 PREMIUM 12000 4 DIESEL 12000 I62300 JUL 12, 2017 9:35 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 10800 2 UNLEADED 2 10800 3 PREMIUM 10800 4 DIESEL 10800 I62200 JUL 12, 2017 9:35 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 11400 2 UNLEADED 2 11400 3 PREMIUM 11400 4 DIESEL 11400 I62900 JUL 12, 2017 9:35 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 600 2 UNLEADED 2 1800 3 PREMIUM 1800 4 DIESEL 1800 I62100 JUL 12, 2017 9:35 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 500 2 UNLEADED 2 500 3 PREMIUM 500 4 DIESEL 500 I62600 JUL 12, 2017 9:35 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 UNLEADED 2 99 3 PREMIUM 99 4 DIESEL 99 I62500 JUL 12, 2017 9:35 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 UNLEADED 2 99 3 PREMIUM 99 4 DIESEL 99 I60800 JUL 12, 2017 9:35 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 UNLEADED 2 0.00 3 PREMIUM 0.00 4 DIESEL 0.00 I60B00 JUL 12, 2017 9:35 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 JUL 12, 2017 9:35 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 UNLEADED 2 0.00 3 PREMIUM 0.00 4 DIESEL 0.00 I61200 JUL 12, 2017 9:35 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED 2 NONE 2 UNLEADED 2 1 NONE 3 PREMIUM NONE NONE 4 DIESEL NONE NONE I63600 JUL 12, 2017 9:35 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 UNLEADED 2 120 3 PREMIUM 120 4 DIESEL 120 I62A00 JUL 12, 2017 9:35 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 UNLEADED 2 120 3 PREMIUM 120 4 DIESEL 120 I62C00 JUL 12, 2017 9:35 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 UNLEADED 2 STANDARD 3 PREMIUM STANDARD 4 DIESEL STANDARD I62D00 JUL 12, 2017 9:36 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 UNLEADED 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 JUL 12, 2017 9:36 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 UNLEADED 2 OFF OFF 3 PREMIUM OFF OFF 4 DIESEL OFF OFF I63000 JUL 12, 2017 9:36 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 UNLEADED 2 OFF 3 PREMIUM OFF 4 DIESEL OFF I63200 JUL 12, 2017 9:36 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 UNLEADED 2 OFF 3 PREMIUM OFF 4 DIESEL OFF I61000 JUL 12, 2017 9:36 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 1 2 UNLEADED 2 1 3 PREMIUM 1 4 DIESEL 1 I63A00 JUL 12, 2017 9:36 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 UNLEADED 2 10.00% 3 PREMIUM 10.00% 4 DIESEL 10.00% I61100 JUL 12, 2017 9:36 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JUL 23, 2010 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 JUL 12, 2017 9:36 AM CSLD PROBABLITY OF DETECTION I61400 JUL 12, 2017 9:36 AM CSLD CLIMATE FACTOR I61600 JUL 12, 2017 9:36 AM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 UNLEADED 2 IMMEDIATE 3 PREMIUM IMMEDIATE 4 DIESEL IMMEDIATE I61A00 JUL 12, 2017 9:36 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED DISABLED 2 UNLEADED 2 DISABLED 3 PREMIUM DISABLED 4 DIESEL DISABLED I61B00 JUL 12, 2017 9:36 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 JUL 12, 2017 9:36 AM CSLD REPORT ONLY I62B00 JUL 12, 2017 9:36 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED ??? 0, 0 2 UNLEADED 2 ??? 0, 0 3 PREMIUM ??? 0, 0 4 DIESEL ??? 0, 0 I63300 JUL 12, 2017 9:36 AM LEAK TEST REPORT FORMAT: NORMAL I63400 JUL 12, 2017 9:36 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 UNLEADED 2 0 3 PREMIUM 0 4 DIESEL 0 I63500 JUL 12, 2017 9:36 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 UNLEADED 2 1 3 PREMIUM 1 4 DIESEL 1 I63900 JUL 12, 2017 9:36 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED END FACTOR: NONE 2 UNLEADED 2 END FACTOR: NONE 3 PREMIUM END FACTOR: NONE 4 DIESEL END FACTOR: NONE I78000 JUL 12, 2017 9:36 AM I77700 JUL 12, 2017 9:36 AM I77800 JUL 12, 2017 9:36 AM I78C00 JUL 12, 2017 9:36 AM I78300 JUL 12, 2017 9:36 AM I78F00 JUL 12, 2017 9:36 AM I78700 JUL 12, 2017 9:36 AM I70200 JUL 12, 2017 9:36 AM LIQUID LABEL DEVICE LABEL 1 UNL ANN 2 UNL FILL 3 UNL STP 4 UNL 2 ANN 5 UNLD 2 FILL 6 UNL 2 STP 7 PREM ANN 8 PREM FILL 9 PREM STP 10 DSL ANN 11 DSL FILL 12 DSL STP 13 DISP 1-2 14 DISP 3 4 15 DISP 5-6 16 DISP 7-8 17 DISP 9-10 18 DISP 11-12 19 20 21 22 23 24 I70300 JUL 12, 2017 9:36 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL ANN TRI-STATE (SINGLE FLOAT) 2 UNL FILL TRI-STATE (SINGLE FLOAT) 3 UNL STP TRI-STATE (SINGLE FLOAT) 4 UNL 2 ANN TRI-STATE (SINGLE FLOAT) 5 UNLD 2 FILL TRI-STATE (SINGLE FLOAT) 6 UNL 2 STP TRI-STATE (SINGLE FLOAT) 7 PREM ANN TRI-STATE (SINGLE FLOAT) 8 PREM FILL TRI-STATE (SINGLE FLOAT) 9 PREM STP TRI-STATE (SINGLE FLOAT) 10 DSL ANN TRI-STATE (SINGLE FLOAT) 11 DSL FILL TRI-STATE (SINGLE FLOAT) 12 DSL STP TRI-STATE (SINGLE FLOAT) 13 DISP 1-2 TRI-STATE (SINGLE FLOAT) 14 DISP 3 4 TRI-STATE (SINGLE FLOAT) 15 DISP 5-6 TRI-STATE (SINGLE FLOAT) 16 DISP 7-8 TRI-STATE (SINGLE FLOAT) 17 DISP 9-10 TRI-STATE (SINGLE FLOAT) 18 DISP 11-12 TRI-STATE (SINGLE FLOAT) 19 TRI-STATE (SINGLE FLOAT) 20 TRI-STATE (SINGLE FLOAT) 21 TRI-STATE (SINGLE FLOAT) 22 TRI-STATE (SINGLE FLOAT) 23 TRI-STATE (SINGLE FLOAT) 24 TRI-STATE (SINGLE FLOAT) I70400 JUL 12, 2017 9:36 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL ANN ANNULAR SPACE 2 UNL FILL PIPING SUMP 3 UNL STP STP SUMP 4 UNL 2 ANN ANNULAR SPACE 5 UNLD 2 FILL PIPING SUMP 6 UNL 2 STP STP SUMP 7 PREM ANN ANNULAR SPACE 8 PREM FILL PIPING SUMP 9 PREM STP STP SUMP 10 DSL ANN ANNULAR SPACE 11 DSL FILL PIPING SUMP 12 DSL STP STP SUMP 13 DISP 1-2 DISPENSER PAN 14 DISP 3 4 DISPENSER PAN 15 DISP 5-6 DISPENSER PAN 16 DISP 7-8 DISPENSER PAN 17 DISP 9-10 DISPENSER PAN 18 DISP 11-12 DISPENSER PAN 19 OTHER SENSORS 20 OTHER SENSORS 21 OTHER SENSORS 22 OTHER SENSORS 23 OTHER SENSORS 24 OTHER SENSORS I74200 JUL 12, 2017 9:36 AM I74300 JUL 12, 2017 9:36 AM I74400 JUL 12, 2017 9:36 AM I74700 JUL 12, 2017 9:36 AM I74800 JUL 12, 2017 9:36 AM I74900 JUL 12, 2017 9:36 AM I7BC00 JUL 12, 2017 9:36 AM I80200 JUL 12, 2017 9:36 AM I80300 JUL 12, 2017 9:36 AM I80400 JUL 12, 2017 9:36 AM I80700 JUL 12, 2017 9:36 AM RELAY LABEL DEVICE LABEL 1 SHUTDOWN 2 OVERFILL ALARM 3 INTERNAL ALARM 4 I80900 JUL 12, 2017 9:36 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 SHUTDOWN NORMALLY CLOSED 2 OVERFILL ALARM NORMALLY OPEN 3 INTERNAL ALARM NORMALLY OPEN 4 NORMALLY OPEN I80B00 JUL 12, 2017 9:36 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 SHUTDOWN 3 2 OVERFILL ALARM NONE 3 INTERNAL ALARM NONE 4 NONE I80A00 JUL 12, 2017 9:36 AM RELAY TYPE RELAY DESIGNATION TYPE 1 SHUTDOWN STANDARD 2 OVERFILL ALARM STANDARD 3 INTERNAL ALARM MOMENTARY 4 STANDARD I80C00 JUL 12, 2017 9:36 AM I80800 JUL 12, 2017 9:36 AM RELAY SETUP REPORT R 1:SHUTDOWN TYPE: STANDARD NORMALLY CLOSED TANK #: 3 LIQUID SENSOR ALMS L 3:FUEL ALARM L 6:FUEL ALARM L 9:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L17:FUEL ALARM L18:FUEL ALARM L 3:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L17:SENSOR OUT ALARM L18:SENSOR OUT ALARM L 3:SHORT ALARM L 6:SHORT ALARM L 9:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM L17:SHORT ALARM L18:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 3:INTERNAL ALARM TYPE: MOMENTARY NORMALLY OPEN IN-TANK ALARMS ALL:LEAK ALARM ALL:HIGH WATER ALARM ALL:OVERFILL ALARM ALL:LOW PRODUCT ALARM ALL:SUDDEN LOSS ALARM ALL:HIGH PRODUCT ALARM ALL:INVALID FUEL LEVEL ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED ALL:MAX PRODUCT ALARM ALL:GROSS TEST FAIL ALL:PERIODIC TEST FAIL ALL:ANNUAL TEST FAIL ALL:PER TST NEEDED WRN ALL:ANN TST NEEDED WRN ALL:PER TST NEEDED ALM ALL:ANN TST NEEDED ALM ALL:TANK TEST ACTIVE ALL:NO CSLD IDLE TIME ALL:TANK SIPHON BREAK ALL:LOW TEMP WARNING LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM SMARTSENSOR ALARMS ALL:SETUP DATA WARNING ALL:COMMUNICATION ALARM ALL:SENSOR FAULT ALARM ALL:FUEL WARNING ALL:FUEL ALARM ALL:WATER WARNING ALL:WATER ALARM ALL:HIGH LIQUID WARNING ALL:HIGH LIQUID ALARM ALL:LOW LIQUID WARNING ISD SITE ALARMS ISD STAGE I WARN ISD GROSS PRES WARN ISD GROSS PRES FAIL ISD DEGRD PRES WARN ISD DEGRD PRES FAIL ISD VAPOR LEAK WARN ISD VAPOR LEAK FAIL ISD VP PRES WARN ISD VP PRES FAIL ISD VP STATUS WARN ISD VP STATUS FAIL MISSING RELAY SETUP MISSING HOSE SETUP MISSING TANK SETUP MISS VAPOR FLOW MTR MISS VAPOR PRES SEN MISSING VP INPUT ISD SETUP WARN ISD SETUP FAIL ISD SENSOR OUT WARN ISD SENSOR OUT FAIL R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 JUL 12, 2017 9:36 AM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 JUL 12, 2017 9:36 AM I72300 JUL 12, 2017 9:36 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 PS 11-12 VAPOR PRESSURE 02 FM 1-2 AIR FLOW METER 03 FM 3-4 AIR FLOW METER 04 FM 5-6 AIR FLOW METER 05 FM 7-8 AIR FLOW METER 06 FM 9-10 AIR FLOW METER 07 FM 11,12 AIR FLOW METER 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 JUL 12, 2017 9:37 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 JUL 12, 2017 9:37 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 JUL 12, 2017 9:37 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA VAPOR PROCESSOR TYPE NONE IV4700 JUL 12, 2017 9:37 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 JUL 12, 2017 9:37 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA ACCEPT HIGH ORVR: NO IV4A00 JUL 12, 2017 9:37 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 01 01 01 BLEND3 02 02 02 01 BLEND3 03 03 03 02 BLEND3 04 04 04 02 BLEND3 05 05 05 03 BLEND3 06 06 06 03 BLEND3 07 07 07 04 BLEND3 08 08 08 04 BLEND3 09 09 09 05 BLEND3 10 10 10 05 BLEND3 11 11 11 06 BLEND3 12 12 12 06 BLEND3 IV4B00 JUL 12, 2017 9:37 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx 09 05 02/09 03/09 09/09 xx/xx 10 05 02/10 03/10 09/10 xx/xx 11 06 02/11 03/11 09/11 xx/xx 12 06 02/12 03/12 09/12 xx/xx IV4900 JUL 12, 2017 9:37 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 JUL 12, 2017 9:37 AM ISD VERSION: 01.03 Jaco 3366 Alarm History 7-12-17 Responses Received: I10200 JUL 12, 2017 9:39 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39308 39679 2 4 PROBE / G.T. 163130 164230 3 INTERSTITIAL BD 201617 202676 4 INTERSTITIAL BD 201550 202698 5 INTERSTITIAL BD 200687 201723 6 UNUSED 9589359 9833789 7 UNUSED 9585305 9788671 8 UNUSED 9586069 9780482 9 UNUSED 9578836 9774189 10 RELAY BOARD 14886 14910 11 UNUSED 9579409 9770033 12 UNUSED 9583972 9766043 13 UNUSED 9587176 9760307 14 UNUSED 9579260 9762489 15 UNUSED 9582528 9756296 16 UNUSED 9575546 9749126 COMM 1 ELEC DISP INT. 100892 101046 COMM 2 RS232 SERIAL BD 14993 14993 COMM 3 RS232 SERIAL BD 14971 14993 COMM 4 UNUSED 9590105 9773545 COMM 5 UNUSED 9578305 9762946 COMM 6 UNUSED 9585648 9755173 I90200 JUL 12, 2017 9:39 AM SOFTWARE REVISION LEVEL VERSION 330.01 SOFTWARE# 346330-100-B CREATED - 10.07.23.17.25 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 JUL 12, 2017 9:39 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L12 STP SUMP DSL STP FUEL ALARM CLEAR 7-07-17 3:15PM L12 STP SUMP DSL STP FUEL ALARM ALARM 7-07-17 3:11PM L 4 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 7-07-17 11:20AM L 4 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 7-07-17 11:18AM L 4 ANNULAR UNL 2 ANN FUEL ALARM CLEAR 7-07-17 11:17AM L 4 ANNULAR UNL 2 ANN FUEL ALARM ALARM 7-07-17 11:17AM L 4 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 7-07-17 11:14AM L 4 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 7-07-17 11:10AM T 2 TANK UNLEADED 2 HIGH WATER ALARM CLEAR 7-07-17 11:03AM T 2 TANK UNLEADED 2 PROBE OUT CLEAR 7-07-17 11:03AM T 1 TANK UNLEADED PROBE OUT CLEAR 7-07-17 11:01AM T 2 TANK UNLEADED 2 PROBE OUT ALARM 7-07-17 11:00AM T 1 TANK UNLEADED PROBE OUT ALARM 7-07-17 11:00AM T 2 TANK UNLEADED 2 OVERFILL ALARM CLEAR 7-07-17 10:59AM T 2 TANK UNLEADED 2 OVERFILL ALARM ALARM 7-07-17 10:57AM T 2 TANK UNLEADED 2 HIGH WATER ALARM ALARM 7-07-17 10:49AM L14 DISP PAN DISP 3 4 FUEL ALARM CLEAR 7-07-17 10:34AM L14 DISP PAN DISP 3 4 FUEL ALARM ALARM 7-07-17 10:34AM L15 DISP PAN DISP 5-6 FUEL ALARM CLEAR 7-07-17 10:34AM L15 DISP PAN DISP 5-6 FUEL ALARM ALARM 7-07-17 10:33AM L16 DISP PAN DISP 7-8 FUEL ALARM CLEAR 7-07-17 10:33AM L16 DISP PAN DISP 7-8 FUEL ALARM ALARM 7-07-17 10:33AM L17 DISP PAN DISP 9-10 FUEL ALARM CLEAR 7-07-17 10:33AM L17 DISP PAN DISP 9-10 FUEL ALARM ALARM 7-07-17 10:32AM L12 STP SUMP DSL STP FUEL ALARM CLEAR 7-07-17 10:32AM L18 DISP PAN DISP 11-12 FUEL ALARM CLEAR 7-07-17 10:32AM L12 STP SUMP DSL STP FUEL ALARM ALARM 7-07-17 10:32AM L18 DISP PAN DISP 11-12 FUEL ALARM ALARM 7-07-17 10:32AM L13 DISP PAN DISP 1-2 FUEL ALARM CLEAR 7-07-17 10:31AM L13 DISP PAN DISP 1-2 FUEL ALARM ALARM 7-07-17 10:31AM T 4 TANK DIESEL PROBE OUT CLEAR 7-07-17 10:31AM T 4 TANK DIESEL PROBE OUT ALARM 7-07-17 10:27AM T 3 TANK PREMIUM PROBE OUT CLEAR 7-07-17 10:25AM T 3 TANK PREMIUM PROBE OUT ALARM 7-07-17 10:24AM T 3 TANK PREMIUM OVERFILL ALARM CLEAR 7-07-17 10:24AM T 3 TANK PREMIUM OVERFILL ALARM ALARM 7-07-17 10:22AM L 1 ANNULAR UNL ANN FUEL ALARM CLEAR 7-07-17 10:20AM L 1 ANNULAR UNL ANN FUEL ALARM ALARM 7-07-17 10:20AM L 7 ANNULAR PREM ANN FUEL ALARM CLEAR 7-07-17 10:19AM L10 ANNULAR DSL ANN FUEL ALARM CLEAR 7-07-17 10:19AM L 7 ANNULAR PREM ANN FUEL ALARM ALARM 7-07-17 10:19AM L10 ANNULAR DSL ANN FUEL ALARM ALARM 7-07-17 10:18AM L 2 PIPE UNL FILL FUEL ALARM CLEAR 7-07-17 10:17AM L 2 PIPE UNL FILL FUEL ALARM ALARM 7-07-17 10:17AM L 5 PIPE UNLD 2 FILL FUEL ALARM CLEAR 7-07-17 10:17AM L 5 PIPE UNLD 2 FILL FUEL ALARM ALARM 7-07-17 10:17AM L 8 PIPE PREM FILL FUEL ALARM CLEAR 7-07-17 10:16AM L 8 PIPE PREM FILL FUEL ALARM ALARM 7-07-17 10:16AM L12 STP SUMP DSL STP FUEL ALARM CLEAR 7-07-17 10:16AM L12 STP SUMP DSL STP FUEL ALARM ALARM 7-07-17 10:16AM I11200 JUL 12, 2017 9:39 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK UNLEADED 2 HIGH WATER WARNING CLEAR 7-07-17 11:03AM T 1 TANK UNLEADED HIGH PRODUCT ALARM CLEAR 7-07-17 11:00AM T 1 TANK UNLEADED HIGH PRODUCT ALARM ALARM 7-07-17 10:59AM T 2 TANK UNLEADED 2 HIGH WATER WARNING ALARM 7-07-17 10:49AM T 4 TANK DIESEL HIGH PRODUCT ALARM CLEAR 7-07-17 10:25AM T 4 TANK DIESEL HIGH PRODUCT ALARM ALARM 7-07-17 10:25AM T 3 TANK PREMIUM HIGH PRODUCT ALARM CLEAR 7-07-17 10:23AM T 3 TANK PREMIUM HIGH PRODUCT ALARM ALARM 7-07-17 10:22AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 7-07-17 9:33AM T 4 TANK DIESEL DELIVERY NEEDED ALARM 7-07-17 9:32AM SYSTEM PRINTER ERROR CLEAR 6-26-17 1:59AM SYSTEM PAPER OUT CLEAR 6-26-17 1:59AM SYSTEM PRINTER ERROR ALARM 6-26-17 1:58AM SYSTEM PAPER OUT ALARM 6-26-17 1:58AM SYSTEM PRINTER ERROR CLEAR 6-26-17 1:58AM SYSTEM PAPER OUT CLEAR 6-26-17 1:58AM SYSTEM PRINTER ERROR ALARM 6-26-17 1:58AM SYSTEM PAPER OUT ALARM 6-26-17 1:58AM SYSTEM PRINTER ERROR CLEAR 6-26-17 1:58AM SYSTEM PAPER OUT CLEAR 6-26-17 1:58AM SYSTEM PRINTER ERROR ALARM 6-26-17 1:58AM SYSTEM PAPER OUT ALARM 6-26-17 1:58AM SYSTEM PRINTER ERROR CLEAR 6-26-17 1:58AM SYSTEM PAPER OUT CLEAR 6-26-17 1:58AM SYSTEM PAPER OUT ALARM 6-26-17 1:58AM SYSTEM PRINTER ERROR ALARM 6-26-17 1:58AM SYSTEM PRINTER ERROR CLEAR 6-26-17 1:58AM SYSTEM PAPER OUT CLEAR 6-26-17 1:58AM SYSTEM PRINTER ERROR ALARM 6-26-17 1:53AM SYSTEM PAPER OUT ALARM 6-26-17 1:53AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 5-12-17 1:56AM T 4 TANK DIESEL DELIVERY NEEDED ALARM 5-11-17 6:36AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 5-10-17 10:00AM SYSTEM PRINTER ERROR CLEAR 5-08-17 3:22AM SYSTEM PRINTER ERROR ALARM 5-08-17 3:21AM SYSTEM PRINTER ERROR CLEAR 5-08-17 3:20AM SYSTEM PAPER OUT CLEAR 5-08-17 3:20AM SYSTEM PRINTER ERROR ALARM 5-08-17 3:20AM SYSTEM PAPER OUT ALARM 5-08-17 3:20AM SYSTEM PRINTER ERROR CLEAR 5-08-17 3:20AM SYSTEM PAPER OUT CLEAR 5-08-17 3:20AM SYSTEM PRINTER ERROR ALARM 5-08-17 3:20AM SYSTEM PAPER OUT ALARM 5-08-17 3:20AM SYSTEM PRINTER ERROR CLEAR 5-08-17 3:20AM SYSTEM PAPER OUT CLEAR 5-08-17 3:20AM SYSTEM PRINTER ERROR ALARM 5-08-17 3:20AM SYSTEM PAPER OUT ALARM 5-08-17 3:20AM SYSTEM PRINTER ERROR CLEAR 5-08-17 3:20AM SYSTEM PAPER OUT CLEAR 5-08-17 3:20AM SYSTEM PRINTER ERROR ALARM 5-08-17 3:20AM I20600 JUL 12, 2017 9:39 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM MAY 29, 2017 2:56 PM APR 3, 2017 2:42 PM MAR 22, 2017 3:39 AM LOW PRODUCT ALARM FEB 15, 2016 8:32 PM JAN 31, 2016 10:33 AM JAN 12, 2016 7:21 AM HIGH PRODUCT ALARM JUL 7, 2017 10:59 AM OCT 18, 2016 7:06 AM JUL 14, 2016 10:00 AM INVALID FUEL LEVEL FEB 15, 2016 10:11 PM JAN 31, 2016 10:51 AM JAN 12, 2016 8:33 AM PROBE OUT JUL 7, 2017 11:00 AM JUL 7, 2017 9:24 AM JUL 7, 2016 2:16 PM DELIVERY NEEDED FEB 15, 2016 7:27 PM JAN 31, 2016 9:24 AM JAN 12, 2016 5:45 AM MAX PRODUCT ALARM JUL 14, 2016 10:00 AM JUL 14, 2016 9:59 AM JUL 14, 2016 9:55 AM LOW TEMP WARNING JUL 7, 2016 9:43 AM JUL 7, 2015 10:24 AM TANK 2 UNLEADED 2 HIGH WATER ALARM JUL 7, 2017 10:49 AM OVERFILL ALARM JUL 7, 2017 10:57 AM JUL 2, 2017 11:02 PM JUN 27, 2017 5:50 AM LOW PRODUCT ALARM JAN 12, 2016 9:34 AM NOV 12, 2014 7:42 PM HIGH PRODUCT ALARM APR 11, 2017 12:13 PM FEB 20, 2017 11:40 AM JUL 14, 2016 10:01 AM INVALID FUEL LEVEL JAN 12, 2016 10:55 AM NOV 12, 2014 7:43 PM PROBE OUT JUL 7, 2017 11:00 AM JUL 7, 2017 9:21 AM JUL 7, 2016 3:26 PM HIGH WATER WARNING JUL 7, 2017 10:49 AM DELIVERY NEEDED JUL 7, 2016 9:56 AM FEB 21, 2016 9:11 PM JAN 30, 2016 2:58 PM MAX PRODUCT ALARM JUL 7, 2014 11:41 AM LOW TEMP WARNING JUL 7, 2016 3:23 PM JUL 15, 2015 10:31 AM JUL 7, 2015 10:31 AM TANK 3 PREMIUM HIGH WATER ALARM JUL 7, 2016 12:51 PM JUL 7, 2016 12:32 PM OVERFILL ALARM JUL 7, 2017 10:22 AM MAY 25, 2017 5:32 AM JAN 23, 2017 7:15 AM LOW PRODUCT ALARM FEB 13, 2016 3:08 PM JAN 12, 2016 10:27 AM JAN 4, 2016 9:23 AM HIGH PRODUCT ALARM JUL 7, 2017 10:22 AM JUL 14, 2016 10:02 AM JUL 7, 2016 2:01 PM INVALID FUEL LEVEL JAN 12, 2016 12:01 PM JAN 4, 2016 11:55 AM NOV 20, 2015 5:24 PM PROBE OUT JUL 7, 2017 10:24 AM JUL 7, 2017 9:33 AM JUL 7, 2016 4:07 PM HIGH WATER WARNING JUL 7, 2016 2:04 PM JUL 7, 2016 12:51 PM JUL 7, 2016 12:32 PM DELIVERY NEEDED FEB 22, 2016 5:14 PM FEB 16, 2016 3:21 PM FEB 15, 2016 9:38 AM LOW TEMP WARNING JUL 15, 2015 10:36 AM JUL 7, 2015 10:36 AM TANK 4 DIESEL OVERFILL ALARM JUL 7, 2016 4:30 PM JUL 15, 2015 10:39 AM JUL 7, 2015 10:41 AM LOW PRODUCT ALARM FEB 19, 2016 5:25 PM JUL 23, 2010 8:05 AM HIGH PRODUCT ALARM JUL 7, 2017 10:25 AM JUL 14, 2016 10:04 AM JUL 7, 2016 4:30 PM PROBE OUT JUL 7, 2017 10:27 AM JUL 7, 2017 9:32 AM JUL 7, 2016 4:30 PM DELIVERY NEEDED JUL 7, 2017 9:32 AM MAY 11, 2017 6:36 AM MAY 6, 2017 10:59 AM MAX PRODUCT ALARM JUL 14, 2016 10:04 AM LOW TEMP WARNING JUL 15, 2015 10:39 AM JUL 7, 2015 10:42 AM JUL 7, 2014 11:48 AM I38200 JUL 12, 2017 9:39 AM I30200 JUL 12, 2017 9:39 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL ANN JUL 7, 2017 10:20 AM FUEL ALARM JUL 14, 2016 9:46 AM SENSOR OUT ALARM JUL 14, 2016 9:13 AM FUEL ALARM 2 UNL FILL JUL 7, 2017 10:17 AM FUEL ALARM FEB 27, 2017 3:04 PM FUEL ALARM FEB 18, 2017 12:47 PM FUEL ALARM 3 UNL STP JUL 7, 2017 10:04 AM FUEL ALARM JAN 27, 2017 6:03 PM FUEL ALARM JUL 14, 2016 9:46 AM SENSOR OUT ALARM 4 UNL 2 ANN JUL 7, 2017 11:18 AM SENSOR OUT ALARM JUL 7, 2017 11:17 AM FUEL ALARM JUL 7, 2017 11:10 AM SENSOR OUT ALARM 5 UNLD 2 FILL JUL 7, 2017 10:17 AM FUEL ALARM FEB 10, 2017 5:00 AM FUEL ALARM JAN 20, 2017 1:25 PM FUEL ALARM 6 UNL 2 STP JUL 7, 2017 10:04 AM FUEL ALARM AUG 15, 2016 11:08 AM FUEL ALARM JUL 14, 2016 2:54 PM FUEL ALARM 7 PREM ANN JUL 7, 2017 10:19 AM FUEL ALARM AUG 15, 2016 7:04 PM FUEL ALARM JUL 14, 2016 9:46 AM SENSOR OUT ALARM 8 PREM FILL JUL 7, 2017 10:16 AM FUEL ALARM JUL 14, 2016 9:46 AM SENSOR OUT ALARM JUL 14, 2016 9:23 AM FUEL ALARM 9 PREM STP JUL 7, 2017 10:13 AM FUEL ALARM JUL 7, 2017 10:12 AM SENSOR OUT ALARM JUL 7, 2017 10:08 AM SENSOR OUT ALARM 10 DSL ANN JUL 7, 2017 10:18 AM FUEL ALARM JUL 14, 2016 9:46 AM FUEL ALARM JUL 14, 2016 9:31 AM FUEL ALARM 11 DSL FILL JUL 7, 2017 10:13 AM FUEL ALARM FEB 17, 2017 4:08 PM FUEL ALARM FEB 10, 2017 4:29 PM FUEL ALARM 12 DSL STP JUL 7, 2017 3:11 PM FUEL ALARM JUL 7, 2017 10:32 AM FUEL ALARM JUL 7, 2017 10:16 AM FUEL ALARM 13 DISP 1-2 JUL 7, 2017 10:31 AM FUEL ALARM JUL 14, 2016 9:45 AM FUEL ALARM JUL 14, 2016 9:39 AM FUEL ALARM 14 DISP 3 4 JUL 7, 2017 10:34 AM FUEL ALARM JUL 14, 2016 9:40 AM FUEL ALARM JUL 7, 2016 11:44 AM FUEL ALARM 15 DISP 5-6 JUL 7, 2017 10:33 AM FUEL ALARM JUL 14, 2016 9:46 AM SENSOR OUT ALARM JUL 14, 2016 9:41 AM FUEL ALARM 16 DISP 7-8 JUL 7, 2017 10:33 AM FUEL ALARM JUL 14, 2016 9:46 AM SENSOR OUT ALARM JUL 14, 2016 9:41 AM FUEL ALARM 17 DISP 9-10 JUL 7, 2017 10:32 AM FUEL ALARM JUL 14, 2016 9:45 AM SENSOR OUT ALARM JUL 14, 2016 9:42 AM FUEL ALARM 18 DISP 11-12 JUL 7, 2017 10:32 AM FUEL ALARM JUL 14, 2016 9:45 AM SENSOR OUT ALARM JUL 14, 2016 9:43 AM FUEL ALARM I31600 JUL 12, 2017 9:39 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 11-12 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 6 FM 9-10 7 FM 11,12 I40200 JUL 12, 2017 9:39 AM I40300 JUL 12, 2017 9:39 AM I34200 JUL 12, 2017 9:39 AM I34700 JUL 12, 2017 9:39 AM IV0100 JUL 12, 2017 9:39 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.03 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 17-05-09 10:01:32 A/L RATIO DEGRADATION FP12 BLEND3 0.79 17-05-08 10:01:27 A/L RATIO DEGRADATION FP12 BLEND3 0.78 17-05-07 10:01:28 A/L RATIO DEGRADATION FP12 BLEND3 0.80 17-03-11 10:02:27 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 3:FM 5-6 17-03-11 10:02:27 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 17-03-01 10:01:47 A/L RATIO DEGRADATION FP12 BLEND3 0.78 17-02-28 10:01:54 A/L RATIO DEGRADATION FP12 BLEND3 0.80 17-01-17 10:01:45 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 2:FM 3-4 17-01-16 10:01:46 A/L RATIO DEGRADATION FP12 BLEND3 0.78 17-01-15 10:02:00 A/L RATIO DEGRADATION FP12 BLEND3 0.78 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 13-12-19 10:03:28 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 5.00 13-12-17 09:07:46 A/L RATIO DEGRADATION FP 5 BLEND3 0.72 11-05-16 10:01:56 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 11-05-16 10:01:56 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 17-03-12 03:00:00 TIME CHANGE DETECTED AT: 17-03-12 02:00:13 17-03-11 15:39:13 COLLECTION TEST HH03 GRADE TEST MANUALLY CLEARED 17-03-11 15:38:28 SENSOR OUT TEST MANUALLY CLEARED 17-03-11 15:37:21 COLLECTION TEST HH05 GRADE TEST MANUALLY CLEARED 17-03-02 08:59:40 COLLECTION TEST HH12 GRADE TEST MANUALLY CLEARED 17-02-25 10:01:52 READINESS ISD:PP EVR:PP ISD & EVR READY 17-02-25 05:20:51 READINESS ISD:PP EVR:NN EVR READINESS PENDING 17-02-25 05:20:51 ISD STARTUP 17-02-25 04:19:12 ISD SHUTDOWN 17-01-17 14:23:39 SENSOR OUT TEST MANUALLY CLEARED Jaco 3366 Alarm History After 7-12-17 Responses Received: I10200 JUL 12, 2017 10:46 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39308 39307 2 4 PROBE / G.T. 163130 163007 3 INTERSTITIAL BD 201617 201444 4 INTERSTITIAL BD 201550 201399 5 INTERSTITIAL BD 200687 200545 6 UNUSED 9589359 9435677 7 UNUSED 9585305 9432099 8 UNUSED 9586069 9427702 9 UNUSED 9578836 9428896 10 RELAY BOARD 14886 14920 11 UNUSED 9579409 9431267 12 UNUSED 9583972 9433142 13 UNUSED 9587176 9429952 14 UNUSED 9579260 9428465 15 UNUSED 9582528 9423206 16 UNUSED 9575546 9428530 COMM 1 ELEC DISP INT. 100892 100952 COMM 2 RS232 SERIAL BD 14993 15007 COMM 3 RS232 SERIAL BD 14971 15007 COMM 4 UNUSED 9590105 9433875 COMM 5 UNUSED 9578305 9430599 COMM 6 UNUSED 9585648 9423077 I90200 JUL 12, 2017 10:46 AM SOFTWARE REVISION LEVEL VERSION 330.01 SOFTWARE# 346330-100-B CREATED - 10.07.23.17.25 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 JUL 12, 2017 10:46 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 6 STP SUMP UNL 2 STP SENSOR OUT ALARM CLEAR 7-12-17 10:45AM L 5 PIPE UNLD 2 FILL SENSOR OUT ALARM CLEAR 7-12-17 10:45AM L 8 PIPE PREM FILL SENSOR OUT ALARM CLEAR 7-12-17 10:45AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 7-12-17 10:45AM L 7 ANNULAR PREM ANN SENSOR OUT ALARM CLEAR 7-12-17 10:45AM L 4 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 7-12-17 10:44AM L 2 PIPE UNL FILL SENSOR OUT ALARM CLEAR 7-12-17 10:44AM L16 DISP PAN DISP 7-8 FUEL ALARM CLEAR 7-12-17 10:44AM L 3 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 7-12-17 10:44AM L12 STP SUMP DSL STP FUEL ALARM CLEAR 7-12-17 10:44AM L11 PIPE DSL FILL FUEL ALARM CLEAR 7-12-17 10:44AM L10 ANNULAR DSL ANN FUEL ALARM CLEAR 7-12-17 10:44AM L15 DISP PAN DISP 5-6 FUEL ALARM CLEAR 7-12-17 10:44AM L14 DISP PAN DISP 3 4 FUEL ALARM CLEAR 7-12-17 10:44AM L13 DISP PAN DISP 1-2 FUEL ALARM CLEAR 7-12-17 10:44AM L18 DISP PAN DISP 11-12 SENSOR OUT ALARM CLEAR 7-12-17 10:44AM L 9 STP SUMP PREM STP FUEL ALARM CLEAR 7-12-17 10:44AM L17 DISP PAN DISP 9-10 SENSOR OUT ALARM CLEAR 7-12-17 10:44AM L11 PIPE DSL FILL SENSOR OUT ALARM CLEAR 7-12-17 10:43AM L11 PIPE DSL FILL FUEL ALARM ALARM 7-12-17 10:43AM L18 DISP PAN DISP 11-12 SENSOR OUT ALARM ALARM 7-12-17 10:43AM L10 ANNULAR DSL ANN FUEL ALARM ALARM 7-12-17 10:43AM L12 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 7-12-17 10:43AM L12 STP SUMP DSL STP FUEL ALARM ALARM 7-12-17 10:43AM L17 DISP PAN DISP 9-10 SENSOR OUT ALARM ALARM 7-12-17 10:43AM L 9 STP SUMP PREM STP FUEL ALARM ALARM 7-12-17 10:43AM L16 DISP PAN DISP 7-8 FUEL ALARM ALARM 7-12-17 10:43AM L 8 PIPE PREM FILL SENSOR OUT ALARM ALARM 7-12-17 10:43AM L15 DISP PAN DISP 5-6 FUEL ALARM ALARM 7-12-17 10:43AM L14 DISP PAN DISP 3 4 FUEL ALARM ALARM 7-12-17 10:43AM L 7 ANNULAR PREM ANN SENSOR OUT ALARM ALARM 7-12-17 10:43AM L12 STP SUMP DSL STP SENSOR OUT ALARM ALARM 7-12-17 10:43AM L13 DISP PAN DISP 1-2 FUEL ALARM ALARM 7-12-17 10:43AM L 6 STP SUMP UNL 2 STP SENSOR OUT ALARM ALARM 7-12-17 10:43AM L 4 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 7-12-17 10:43AM L 5 PIPE UNLD 2 FILL SENSOR OUT ALARM ALARM 7-12-17 10:43AM L 3 STP SUMP UNL STP SENSOR OUT ALARM ALARM 7-12-17 10:43AM L11 PIPE DSL FILL SENSOR OUT ALARM ALARM 7-12-17 10:43AM L 2 PIPE UNL FILL SENSOR OUT ALARM ALARM 7-12-17 10:43AM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 7-12-17 10:43AM L18 DISP PAN DISP 11-12 FUEL ALARM CLEAR 7-12-17 10:37AM L18 DISP PAN DISP 11-12 FUEL ALARM ALARM 7-12-17 10:37AM L17 DISP PAN DISP 9-10 FUEL ALARM CLEAR 7-12-17 10:37AM L17 DISP PAN DISP 9-10 FUEL ALARM ALARM 7-12-17 10:36AM L16 DISP PAN DISP 7-8 FUEL ALARM CLEAR 7-12-17 10:36AM L16 DISP PAN DISP 7-8 FUEL ALARM ALARM 7-12-17 10:35AM L15 DISP PAN DISP 5-6 FUEL ALARM CLEAR 7-12-17 10:35AM L15 DISP PAN DISP 5-6 FUEL ALARM ALARM 7-12-17 10:35AM L14 DISP PAN DISP 3 4 FUEL ALARM CLEAR 7-12-17 10:34AM L14 DISP PAN DISP 3 4 FUEL ALARM ALARM 7-12-17 10:34AM I11200 JUL 12, 2017 10:46 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK UNLEADED LOW TEMP WARNING CLEAR 7-12-17 10:17AM T 1 TANK UNLEADED LOW TEMP WARNING ALARM 7-12-17 10:17AM T 4 TANK DIESEL LOW TEMP WARNING CLEAR 7-12-17 10:11AM T 4 TANK DIESEL LOW TEMP WARNING ALARM 7-12-17 10:11AM T 4 TANK DIESEL HIGH PRODUCT ALARM CLEAR 7-12-17 10:00AM T 4 TANK DIESEL HIGH PRODUCT ALARM ALARM 7-12-17 10:00AM T 3 TANK PREMIUM HIGH PRODUCT ALARM CLEAR 7-12-17 9:58AM T 3 TANK PREMIUM HIGH PRODUCT ALARM ALARM 7-12-17 9:58AM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM CLEAR 7-12-17 9:54AM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM ALARM 7-12-17 9:54AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 7-12-17 9:49AM T 4 TANK DIESEL DELIVERY NEEDED ALARM 7-12-17 9:48AM T 2 TANK UNLEADED 2 HIGH WATER WARNING CLEAR 7-07-17 11:03AM T 1 TANK UNLEADED HIGH PRODUCT ALARM CLEAR 7-07-17 11:00AM T 1 TANK UNLEADED HIGH PRODUCT ALARM ALARM 7-07-17 10:59AM T 2 TANK UNLEADED 2 HIGH WATER WARNING ALARM 7-07-17 10:49AM T 4 TANK DIESEL HIGH PRODUCT ALARM CLEAR 7-07-17 10:25AM T 4 TANK DIESEL HIGH PRODUCT ALARM ALARM 7-07-17 10:25AM T 3 TANK PREMIUM HIGH PRODUCT ALARM CLEAR 7-07-17 10:23AM T 3 TANK PREMIUM HIGH PRODUCT ALARM ALARM 7-07-17 10:22AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 7-07-17 9:33AM T 4 TANK DIESEL DELIVERY NEEDED ALARM 7-07-17 9:32AM SYSTEM PRINTER ERROR CLEAR 6-26-17 1:59AM SYSTEM PAPER OUT CLEAR 6-26-17 1:59AM SYSTEM PRINTER ERROR ALARM 6-26-17 1:58AM SYSTEM PAPER OUT ALARM 6-26-17 1:58AM SYSTEM PRINTER ERROR CLEAR 6-26-17 1:58AM SYSTEM PAPER OUT CLEAR 6-26-17 1:58AM SYSTEM PRINTER ERROR ALARM 6-26-17 1:58AM SYSTEM PAPER OUT ALARM 6-26-17 1:58AM SYSTEM PRINTER ERROR CLEAR 6-26-17 1:58AM SYSTEM PAPER OUT CLEAR 6-26-17 1:58AM SYSTEM PRINTER ERROR ALARM 6-26-17 1:58AM SYSTEM PAPER OUT ALARM 6-26-17 1:58AM SYSTEM PRINTER ERROR CLEAR 6-26-17 1:58AM SYSTEM PAPER OUT CLEAR 6-26-17 1:58AM SYSTEM PAPER OUT ALARM 6-26-17 1:58AM SYSTEM PRINTER ERROR ALARM 6-26-17 1:58AM SYSTEM PRINTER ERROR CLEAR 6-26-17 1:58AM SYSTEM PAPER OUT CLEAR 6-26-17 1:58AM SYSTEM PRINTER ERROR ALARM 6-26-17 1:53AM SYSTEM PAPER OUT ALARM 6-26-17 1:53AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 5-12-17 1:56AM T 4 TANK DIESEL DELIVERY NEEDED ALARM 5-11-17 6:36AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 5-10-17 10:00AM SYSTEM PRINTER ERROR CLEAR 5-08-17 3:22AM SYSTEM PRINTER ERROR ALARM 5-08-17 3:21AM SYSTEM PRINTER ERROR CLEAR 5-08-17 3:20AM SYSTEM PAPER OUT CLEAR 5-08-17 3:20AM SYSTEM PRINTER ERROR ALARM 5-08-17 3:20AM I20600 JUL 12, 2017 10:46 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM JUL 12, 2017 9:52 AM MAY 29, 2017 2:56 PM APR 3, 2017 2:42 PM LOW PRODUCT ALARM FEB 15, 2016 8:32 PM JAN 31, 2016 10:33 AM JAN 12, 2016 7:21 AM HIGH PRODUCT ALARM JUL 7, 2017 10:59 AM OCT 18, 2016 7:06 AM JUL 14, 2016 10:00 AM INVALID FUEL LEVEL FEB 15, 2016 10:11 PM JAN 31, 2016 10:51 AM JAN 12, 2016 8:33 AM PROBE OUT JUL 12, 2017 10:16 AM JUL 12, 2017 9:43 AM JUL 7, 2017 11:00 AM DELIVERY NEEDED FEB 15, 2016 7:27 PM JAN 31, 2016 9:24 AM JAN 12, 2016 5:45 AM MAX PRODUCT ALARM JUL 14, 2016 10:00 AM JUL 14, 2016 9:59 AM JUL 14, 2016 9:55 AM LOW TEMP WARNING JUL 12, 2017 10:17 AM JUL 7, 2016 9:43 AM JUL 7, 2015 10:24 AM TANK 2 UNLEADED 2 HIGH WATER ALARM JUL 7, 2017 10:49 AM OVERFILL ALARM JUL 12, 2017 9:54 AM JUL 7, 2017 10:57 AM JUL 2, 2017 11:02 PM LOW PRODUCT ALARM JAN 12, 2016 9:34 AM NOV 12, 2014 7:42 PM HIGH PRODUCT ALARM JUL 12, 2017 9:54 AM APR 11, 2017 12:13 PM FEB 20, 2017 11:40 AM INVALID FUEL LEVEL JAN 12, 2016 10:55 AM NOV 12, 2014 7:43 PM PROBE OUT JUL 12, 2017 10:13 AM JUL 12, 2017 9:46 AM JUL 7, 2017 11:00 AM HIGH WATER WARNING JUL 7, 2017 10:49 AM DELIVERY NEEDED JUL 7, 2016 9:56 AM FEB 21, 2016 9:11 PM JAN 30, 2016 2:58 PM MAX PRODUCT ALARM JUL 7, 2014 11:41 AM LOW TEMP WARNING JUL 7, 2016 3:23 PM JUL 15, 2015 10:31 AM JUL 7, 2015 10:31 AM TANK 3 PREMIUM HIGH WATER ALARM JUL 7, 2016 12:51 PM JUL 7, 2016 12:32 PM OVERFILL ALARM JUL 12, 2017 9:58 AM JUL 7, 2017 10:22 AM MAY 25, 2017 5:32 AM LOW PRODUCT ALARM FEB 13, 2016 3:08 PM JAN 12, 2016 10:27 AM JAN 4, 2016 9:23 AM HIGH PRODUCT ALARM JUL 12, 2017 9:58 AM JUL 7, 2017 10:22 AM JUL 14, 2016 10:02 AM INVALID FUEL LEVEL JAN 12, 2016 12:01 PM JAN 4, 2016 11:55 AM NOV 20, 2015 5:24 PM PROBE OUT JUL 12, 2017 10:12 AM JUL 12, 2017 9:50 AM JUL 7, 2017 10:24 AM HIGH WATER WARNING JUL 7, 2016 2:04 PM JUL 7, 2016 12:51 PM JUL 7, 2016 12:32 PM DELIVERY NEEDED FEB 22, 2016 5:14 PM FEB 16, 2016 3:21 PM FEB 15, 2016 9:38 AM LOW TEMP WARNING JUL 15, 2015 10:36 AM JUL 7, 2015 10:36 AM TANK 4 DIESEL OVERFILL ALARM JUL 12, 2017 10:00 AM JUL 7, 2016 4:30 PM JUL 15, 2015 10:39 AM LOW PRODUCT ALARM JUL 12, 2017 9:48 AM FEB 19, 2016 5:25 PM JUL 23, 2010 8:05 AM HIGH PRODUCT ALARM JUL 12, 2017 10:00 AM JUL 7, 2017 10:25 AM JUL 14, 2016 10:04 AM PROBE OUT JUL 12, 2017 10:10 AM JUL 12, 2017 9:48 AM JUL 7, 2017 10:27 AM DELIVERY NEEDED JUL 12, 2017 9:48 AM JUL 7, 2017 9:32 AM MAY 11, 2017 6:36 AM MAX PRODUCT ALARM JUL 14, 2016 10:04 AM LOW TEMP WARNING JUL 12, 2017 10:11 AM JUL 15, 2015 10:39 AM JUL 7, 2015 10:42 AM I38200 JUL 12, 2017 10:46 AM I30200 JUL 12, 2017 10:46 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL ANN JUL 12, 2017 10:43 AM SENSOR OUT ALARM JUL 12, 2017 10:03 AM FUEL ALARM JUL 7, 2017 10:20 AM FUEL ALARM 2 UNL FILL JUL 12, 2017 10:43 AM SENSOR OUT ALARM JUL 12, 2017 10:20 AM FUEL ALARM JUL 7, 2017 10:17 AM FUEL ALARM 3 UNL STP JUL 12, 2017 10:43 AM SENSOR OUT ALARM JUL 12, 2017 10:29 AM FUEL ALARM JUL 7, 2017 10:04 AM FUEL ALARM 4 UNL 2 ANN JUL 12, 2017 10:43 AM SENSOR OUT ALARM JUL 12, 2017 10:03 AM FUEL ALARM JUL 7, 2017 11:18 AM SENSOR OUT ALARM 5 UNLD 2 FILL JUL 12, 2017 10:43 AM SENSOR OUT ALARM JUL 12, 2017 10:21 AM FUEL ALARM JUL 7, 2017 10:17 AM FUEL ALARM 6 UNL 2 STP JUL 12, 2017 10:43 AM SENSOR OUT ALARM JUL 12, 2017 10:25 AM FUEL ALARM JUL 7, 2017 10:04 AM FUEL ALARM 7 PREM ANN JUL 12, 2017 10:43 AM SENSOR OUT ALARM JUL 12, 2017 10:03 AM FUEL ALARM JUL 7, 2017 10:19 AM FUEL ALARM 8 PREM FILL JUL 12, 2017 10:43 AM SENSOR OUT ALARM JUL 12, 2017 10:21 AM FUEL ALARM JUL 7, 2017 10:16 AM FUEL ALARM 9 PREM STP JUL 12, 2017 10:43 AM FUEL ALARM JUL 12, 2017 10:24 AM FUEL ALARM JUL 7, 2017 10:13 AM FUEL ALARM 10 DSL ANN JUL 12, 2017 10:43 AM FUEL ALARM JUL 12, 2017 10:03 AM FUEL ALARM JUL 7, 2017 10:18 AM FUEL ALARM 11 DSL FILL JUL 12, 2017 10:43 AM FUEL ALARM JUL 12, 2017 10:43 AM SENSOR OUT ALARM JUL 12, 2017 10:22 AM FUEL ALARM 12 DSL STP JUL 12, 2017 10:43 AM FUEL ALARM JUL 12, 2017 10:43 AM SENSOR OUT ALARM JUL 12, 2017 10:24 AM FUEL ALARM 13 DISP 1-2 JUL 12, 2017 10:43 AM FUEL ALARM JUL 12, 2017 10:34 AM FUEL ALARM JUL 7, 2017 10:31 AM FUEL ALARM 14 DISP 3 4 JUL 12, 2017 10:43 AM FUEL ALARM JUL 12, 2017 10:34 AM FUEL ALARM JUL 7, 2017 10:34 AM FUEL ALARM 15 DISP 5-6 JUL 12, 2017 10:43 AM FUEL ALARM JUL 12, 2017 10:35 AM FUEL ALARM JUL 7, 2017 10:33 AM FUEL ALARM 16 DISP 7-8 JUL 12, 2017 10:43 AM FUEL ALARM JUL 12, 2017 10:35 AM FUEL ALARM JUL 7, 2017 10:33 AM FUEL ALARM 17 DISP 9-10 JUL 12, 2017 10:43 AM SENSOR OUT ALARM JUL 12, 2017 10:36 AM FUEL ALARM JUL 7, 2017 10:32 AM FUEL ALARM 18 DISP 11-12 JUL 12, 2017 10:43 AM SENSOR OUT ALARM JUL 12, 2017 10:37 AM FUEL ALARM JUL 7, 2017 10:32 AM FUEL ALARM I31600 JUL 12, 2017 10:46 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 11-12 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 6 FM 9-10 7 FM 11,12 I40200 JUL 12, 2017 10:46 AM I40300 JUL 12, 2017 10:46 AM I34200 JUL 12, 2017 10:46 AM I34700 JUL 12, 2017 10:46 AM IV0100 JUL 12, 2017 10:46 AM FASTRIP 366 8001 WHITE LN BAKERSFIELD CA ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.03 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 17-05-09 10:01:32 A/L RATIO DEGRADATION FP12 BLEND3 0.79 17-05-08 10:01:27 A/L RATIO DEGRADATION FP12 BLEND3 0.78 17-05-07 10:01:28 A/L RATIO DEGRADATION FP12 BLEND3 0.80 17-03-11 10:02:27 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 3:FM 5-6 17-03-11 10:02:27 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 17-03-01 10:01:47 A/L RATIO DEGRADATION FP12 BLEND3 0.78 17-02-28 10:01:54 A/L RATIO DEGRADATION FP12 BLEND3 0.80 17-01-17 10:01:45 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 2:FM 3-4 17-01-16 10:01:46 A/L RATIO DEGRADATION FP12 BLEND3 0.78 17-01-15 10:02:00 A/L RATIO DEGRADATION FP12 BLEND3 0.78 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 13-12-19 10:03:28 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 5.00 13-12-17 09:07:46 A/L RATIO DEGRADATION FP 5 BLEND3 0.72 11-05-16 10:01:56 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 11-05-16 10:01:56 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 17-07-12 10:45:32 READINESS ISD:PP EVR:NN EVR READINESS PENDING 17-07-12 10:45:32 ISD STARTUP 17-07-12 10:45:23 ISD SHUTDOWN 17-03-12 03:00:00 TIME CHANGE DETECTED AT: 17-03-12 02:00:13 17-03-11 15:39:13 COLLECTION TEST HH03 GRADE TEST MANUALLY CLEARED 17-03-11 15:38:28 SENSOR OUT TEST MANUALLY CLEARED 17-03-11 15:37:21 COLLECTION TEST HH05 GRADE TEST MANUALLY CLEARED 17-03-02 08:59:40 COLLECTION TEST HH12 GRADE TEST MANUALLY CLEARED 17-02-25 10:01:52 READINESS ISD:PP EVR:PP ISD & EVR READY 17-02-25 05:20:51 READINESS ISD:PP EVR:NN EVR READINESS PENDING SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator forsubmittal to the local regulatory agency. 1.FACILITY INFORMATION Facility Name:Date of Testing: Facility Address: Facility Contact:Phone: Date Local Agency Was Notified of Testing : Name of Local Agency Inspector (if present during testing): 2.TESTING CONTRACTOR INFORMATION Company Name:Confidence UST Services, Inc. Technician Conducting Test: Credentials1:CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s):CSLB#804904 ICC# 3.SPILL BUCKET TESTING INFORMATION Test Method Used:Hydrostatic Vacuum Other Test Equipment Used:Lake TestEquipment Resolution:0.0625” Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1234 Bucket Installation Type: Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test: Test Start Time (TI): Initial Reading (RI): Test End Time (TF): Final Reading (RF): Test Duration (TF – TI): Change in Reading (RF -RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Comments –(include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician’s Signature:________________________________________________ Date:_________ 1 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. #3366/Fastrip#640(West)07/12/2017 8001WhiteLane Bakersfield,CA93309 OmeroGarcia(661)393-7000 06/08/2017 None present AaronPerrigo 8485827-UT Regular1 12.00" 14.00" 5min. 9:00 am 9.50" 10:00 am 9.50" 1hour 0.00" 0.0625" Regular2(Siphon) 12.00" 15.25" 5min. 9:00 am 9.50" 10:00 am 9.50" 1hour 0.00" 0.0625"0.0625" Super 12.00" 15.00" 5min. 9:00 am 9.50" 10:00 am 9.50" 1hour 0.00" Diesel 12.00" 13.75" 5min. 9:00 am 9.50" 10:00 am 9.50" 1hour 0.00" 0.0625" 07/12/2017