Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3.1-123
LIST OF DRAWINGS SHEET I TITLE SHEET STREET LIGHT IMPROVEMENTS SHEET 2 DETAILS SHEET 3 P STREET —FROM MING AVE TO BELLE TERRACE P STREET N/ r ST -12, ST -23, ST -24, ST -25, ST -26 ES- IA, A88A --------- -- — - FROM MING AVENUE SACRAMENTO • USAN FRANCISCO AND BELLE TERRACE FRESNO MIN CITY OO F BA : ERSFIELD LOS ANGELES SAN DIEGO NO TE: THE CON TRA C TOR MUST POSSESS THE FOL L 0 WING VALID LICENSES: ctAss a OR C- /0 NO TE: THE CON TRA C TOR SHALL CONTACT THE USA L OCA TOR SERVICE 1-800-642-2444, 48 HOURS PRIOR TO EXCA VA TION. Fol EA SEMEN T F.H. EXIST. CURB & GUTTER NOT TO SCALE RIGH T- OF- WA Y EXIS T A. C. FL 0WLINE CEN TERL INE P. -f- P EXIST. EDGE OF PA VEMEN T M C W. RAILROAD TRACKS S �oe NGN GUARD RAIL X CHAIN LINK FENCE IMPRO VEMEN TS -UTILITY SYMBOLS OLS I W EXIST WA TER LINE S EXIS T SEWER LINE G EXIST GAS LINE SD EXIST STORM DRAIN OH EXIST AERIAL E EXIST UNDERGROUND FU TURF MONUMEN T LINES GA S ME TER POWER LINE TV EXIST UNDERGROUND T EXIST UNDERGROUND TV CABLES STREET LIGHT PHONE LINE O EXIS T OIL LINE FO EXIST FIBER OPTIC LINE FROM MING AVENUE SACRAMENTO • USAN FRANCISCO AND BELLE TERRACE FRESNO MIN CITY OO F BA : ERSFIELD LOS ANGELES SAN DIEGO NO TE: THE CON TRA C TOR MUST POSSESS THE FOL L 0 WING VALID LICENSES: ctAss a OR C- /0 NO TE: THE CON TRA C TOR SHALL CONTACT THE USA L OCA TOR SERVICE 1-800-642-2444, 48 HOURS PRIOR TO EXCA VA TION. Fol MANHOLE F.H. FIRE H YDRAN T NOT TO SCALE QRof E SS / ov P. -f- P POWER POLE M C W. WATER METER S �oe NGN W.V. C 80507 El EXISTING MONUMENT WATER VALVE * Exp. 3-31-17 G.M. qTF O I V I \- ❑o FU TURF MONUMEN T ® GA S ME TER OF cm_\F S.L. G.V. 3 STREET LIGHT N GAS VALVE o-� STREET LIGHT W/MAST ARM ii�- BENCHMARK C.O. � CLEAN OUT f AUrO SCOPE ©PRE—EMPTION DEJob No.: P51<223I//CE File Path: S:\PROJECTS\2014-2015\P5K223 - St Light Imp - P Street\AutoCAD Drawings File Name: Street Light Improv P Street.dwg 0.5 MILE 0 1 2 3 N 1 W U W W J W m 0 Q j Z W Q uj Z W CL W W CL Z J uj W z 0 Q J U z Lu Lu U) m 0 w 0 J n 0 d - I I Q N C6 ao 0 (N 2, (N Q) c 7) 0 c 0 3 0 3. U) o_ 0 a E 4- __j J a� a� / c 3 0 L 0 Q U 4. 0 Q / W ai L I a E /Jn V / N N Y o_ N 0 5. N / cn U Li D 0 6. Of cii 6"X6" nnKinoc-rr- APRON AR( 2" THICK MORTAR BED TO SEAL BOX BOTTOM 3/4" CRUSHED R01 UNDER BOX 8" THI( 3/4" PVC DRAIN TO GRAVEL 12'• OLDCASTLE B1017 BOX (SEE NOTES) 18" MIN. RADIUS FOR CONDUITS EXTENDING TO PULL BOXES OR PG&E #2 BOX APPROVED LED MODEL #: AEL AUTOBAHN 143W ATB2 40BLEDE10 MVOLT R2 NL P7 PCLL , QROFESS/pN� I N G/y c F c� ;g7 T_ m RE /STERED Cl VIL ENGINEER C80507 * Exp. 3-31-17 CITY OF BAKERSFIELD 1509 TRUXTUN AVENUE qTF Civi BAKERSFIELD, CA 93,301 OF CA��F REVISIONS No. DA TE DESCRIP TION 1 / / 12' C INTERMEDIATE 2 / / ?PULL BOX DETA/L NOT TO SCALE„) GENERAL NOTES: POLES: TYPE 15-26' TALL, ROUND TAPERED, GALVANIZED POLE WITH 12' ELLIPTICAL MAST ARM HAVING 24” ELEVATION FOR A 28' LUMINAIRE MOUNTING HEIGHT (DETAIL A/2) TYPE 15S-18' TALL, ROUND TAPERED, GALVANIZED POLE WITH 12' ELLIPTICAL MAST ARM HAVING 24" ELEVATION FOR A 20' LUMINAIRE MOUNTING HEIGHT (DETAIL B/2) 4"X 6-1/2" HAND—HOLE COVER WITH 1/4" x 1-1/2" REINFORCEMENT RING WELDED TO OUTSIDE OF POLE. STEEL HAND HOLE COVER TO HAVE TWO 1/4-20 STAINLESS STEEL TAMPERPROOF HEX REJECT SCREWS INSTALL HOT DIPPED GALVANIZED NUTS AND LEVELING WASHERS ON TOP AND BOTTOM OF FLANGE BASE. INSTALL GROUT UNDER BASE AFTER LEVELING. BOLT CIRCLE 11", BOLTS ASTM A-307 1"x36%4" WITH HEX NUT, LEVELING NUT & TWO WASHERS PER BOLT PULL BOX: BOX— OLDCASTLE 81017 OR APPROVED EQUAL WITH GALVANIZED STEEL SKID RESISTANT BOLT DOWN LOCKING LID MARKED "STREET LIGHTS" LOCATE PULL—BOXES AS INDICATED ON PLAN, MAXIMUM 2' FROM POLE BASE INSTALL 8" MINIMUM THICKNESS OF 3/4" CRUSHED ROCK UNDER BOX FOR DRAINAGE INSTALL 2" MORTAR BED ON GRAVEL TO SEAL BOTTOM OF BOX INSTALL 3/4" PVC DRAIN PIPE TO ALLEVIATE STANDING WATER IN PULL BOX 1/2" X 8' COPPER CLAD GROUND RODS ARE REQUIRED IN BOXES FEEDING POLES ONLY—NOT IN INTERMEDIATE PULL BOXES CONDUITS: CONDUITS TO BE GRAY PVC SCHEDULE 40— 1-1/2" FROM POLE TO PULL BOX , USE 2" CONDUIT BETWEEN PULL BOXES ON LONG RUNS INSTALL CONDUITS SO THAT THEY ARE NEATLY ARRANGED IN CENTER PORTION OF BOX, ENTERING BOX PLUMB INSTALL END BELLS ON ALL CONDUITS SEAL CONDUITS WITH DUCT SEAL, COMPLETELY SEALING AROUND CONDUCTORS AND AT LEAST 1" THICK USE 18" RADIUS MINIMUM SWEEPS ON ALL BENDS—EXCEPTION STANDARD SWEEPS ARE OK ON SHORT RUNS BETWEEN PULL BOX AND POLE RUNS SHALL HAVE NO MORE THAN A TOTAL OF 270 DEGREES OF BENDS BETWEEN PULLING POINTS MINIMUM CONDUIT DEPTH SHALL BE 24" BELOW GRADE WIRING: REFER TO PLAN FOR WIRE SIZE IN EACH CONDUIT RUN MINIMUM CONDUCTOR SIZE IS #10 THW STRANDED COPPER IN NEW CONDUITS AND POLES, UNLESS OTHERWISE NOTED USE BLACK FOR PHASE 'A' & RED FOR PHASE 'B' SPLICES IN PULL BOXES SHALL BE MADE WITH STANDARD TIN PLATED UNISULATED COMPRESSION SPLICES OR COPPER COMPRESSION PARALLEL SPLICE, INSULATE SPLICES WITH HEAVY WALL ADHESIVE BASED HEAT SHRINK TUBING (3M 0400, 0800, 1100 OR APPROVED EQUAL), INSTALL 1.5" OF HEAT SHRINK PAST EACH END OF SPLICE, WHEN PARALLEL SPLICES ARE MADE—INSTALL 3" OF HEAT SHRINK PAST EACH END OF SPLICE AND CRIMP THE SPLICE WITH NEEDLE NOSE PLIERS UNTIL THE ADHESIVE HAS COOLED CREATING A WATER TIGHT SEAL AROUND EACH INDIVIDUAL CONDUCTOR. USE PROPER TOOLS TO MAKE CRIMPS PER MANUFACTURES INSTRUCTIONS GROUND WIRE FROM POLE BASE TO GROUND ROD SHALL BE #8 MINIMUM THE CIRCUIT SHALL BE FUSED IN THE PULL BOX ADJACENT TO THE POLE. FUSE HOLDERS SHALL BE FERRAZ SHAWMUT FEX-11-11 600V 30A. INSTALL 3M 0400 HEAT SHRINK (OR APPROVED EQUAL) OVER TERMINATIONS WITH AT LEAST 1" OF HEAT SHRINK TUBING PAST CONNECTION OVER CONDUCTOR INSULATION. FUSES SHALL BE 6A RATED — BUSSMAN KTK6—NO EXCEPTIONS LUMINAIRES: LUMINAIRES SHALL BE LED TYPE ONLY— REFER TO PLAN & DETAILS FOR FIXTURE TYPES INSTALL TORK 2007A TWISTLOCK PHOTOCELL ORIENTED NORTH INSTALLATION: ALL WORK SHALL BE PERFORMED BY A LICENSED C10 ELECTRICAL CONTRACTOR UNDER JOURNEYMAN LEVEL SUPERVISION CITY OF BAKERSFIELD, CALIFORNIA 28' MOUNTING HEIGHT NOTE: LIGHT POLES, ANCHOR BOLTS, MAST ARMS, AND LED FIXTURES WILL BE FURNISHED BY THE CITY OF BAKERSFIELD AND INSTALLED BY CONTRACTOR. (E) CURB & GUTTER (E) SIDEWALK (E) STREET4' < .... . . APPROVED LED MODEL #: AEL AUTOBAHN 143W ATB2 40BLEDE10 MVOLT R4 NL P7 PCLL STAINLESS STEEL TAMPERPROOF SCREW 1. HEX—REJECTION PIN STYLE �3/4" PVC DRAIN FUSE HOLDER OLDCASTLE B1017 BOX TO GRAVEL (SEE NOTES) 6"x6" CLASS B CONCRETE APRON AROUND BOX i 1 n � •.R . s - .b •<� y1s. 1. �. Ye fib. , � •� • 2 2'-6" 0 OR FIELD CAST CLASS A CONCRETE PLACED AGAINST UNDISTURBED SOIL POLE AND PULL BOX DETAIL Im PUBLIC WORKS DEPARTMENT File Noma -Street Light Ir Job No.: P5K223 Dote: dun. 29, 15 ». I d I-'--"III--III••---� I I I (I—III—� I I� � I- 2" THICK MORTAR BED TO SEAL BOX BOTTOM E,xf 3/4"CRUSHED ROCK 0 ea' UNDER BOX 8" THICK 18" MIN. RADIUS FOR CONDUITS EXTENDING TO PULL BOXES OR TRAFFIC SIGNAL BOX 2„ 1/2" x 8' COPPER CLAD 1�1 GROUND ROD TYPE 15 NOT TO SCALE v P StreetDrown: S CLAYTON Engineer: L SUN Checked By.- L%5 NOTE: LIGHT POLES, ANCHOR BOLTS, MAST ARMS, AND LED FIXTURES WILL BE FURNISHED BY THE CITY OF BAKERSFIELD AND INSTALLED BY CONTRACTOR. (E) CURB & GUTTER (E) SIDEWALK (E) STREET t ----8- 20' MOUNTING HEIGHT STAINLESS STEEL TAMPERPROOF SCREW HEX—REJECTION PIN STYLE 3/4" PVC DRAIN FUSE HOLDER OLDCASTLE B1017 BOX TO GRAVEL (SEE NOTES) 6"x6" CLASS B CONCRETE APRON AROUND BOX �. ., 1. . , 2'-6" 0 OR FIELD CAST CLASS A CONCRETE PLACED AGAINST UNDISTURBED SOIL 2" THICK MORTAR BED u„ TO SEAL BOX BOTTOM "CRUSHED ROCK UNDER BOX 8" THICK 18" MIN. RADIUS FOR CONDUITS EXTENDING TO PULL BOXES OR TRAFFIC SIGNAL BOX 2" 1/2" x 8' COPPER CLAD GROUND ROD B POLE AND PULL BOX DETAIL TYPE 15S z NOT TO SCALE CITY RECORD No. STREET LIGHT IMPROVEMENTS P STREET FROM MING AVENUE AND BELLE TERRACE u SHEE T NO. 2 OF 3 2 3 .tt4• , 2'-6" 0 OR FIELD CAST CLASS A CONCRETE PLACED AGAINST UNDISTURBED SOIL 2" THICK MORTAR BED u„ TO SEAL BOX BOTTOM "CRUSHED ROCK UNDER BOX 8" THICK 18" MIN. RADIUS FOR CONDUITS EXTENDING TO PULL BOXES OR TRAFFIC SIGNAL BOX 2" 1/2" x 8' COPPER CLAD GROUND ROD B POLE AND PULL BOX DETAIL TYPE 15S z NOT TO SCALE CITY RECORD No. STREET LIGHT IMPROVEMENTS P STREET FROM MING AVENUE AND BELLE TERRACE u SHEE T NO. 2 OF 3 2 3 Lu Lu 1 € € € € € € E € € € € € € a » » - O Al ._........... 2�- :D 3-t O _....._ 4 -f - W �w - - -- - + O Q= 9-t ....... O 10-10......... ' _.... _�........ zLL w _»__ __» A 2 _»__ ___» »»__ _»__ ___... _.a__ »»__ __» »» _»_» mm___ ``� �0 2 3 4 �Qm Lli_x X X ----------------- X �j ------------- -------- ------------- --- --------- O ' REPLACE EXISTING N30 TRAFFIC SIGNAL BOX WITH NEW _ OLDCASTLE B1 X730 TRAFFIC RATED BOX AD B1730- 51 JH LID. ~ (� 1 ROUTE NEW STREET LIGHT CIRCUIT THROUGH EXISTING CONDUIT € € € € € € 1 INTO METER PLDESTAL AND INSTALL A NSW 2 POLE 30A CIRCUIT N S TT € CO W € € € € € J LO BREAKER ON WN METERED PANEL SECTION. LABEL -"STREETS € € O _ w _»»___ LIGHTS P STR ET". INSTALL 6X6 CONRETE, SKIRT AROUND BOX. o €� E ¥ _ V) € "-" "a: +" "»�` II I +J� + J`0 Q� \0 —i r- + J� Q .0 CO Q W� Q W� Q F -O STA 12+03.24 Z # Z # c ? # Q INSTALL STREET LIGHT #70674 00 SS/0N q S1NGrTl y EGIS TERED I VIL EN (NEER � C 80507 * Exp. 3-31-17 CITY OF BAKERSFIELD �Q CI ��` 9501 TRUXTUN AVENUE 9T F OF CA� BAKERSFIELD, CA 93301 REVISIONS No. DA TE I DESCRIP TION 1 r s A 011� !b e 6 �.� � m W �,, _ _ » . _ _ » W o LU ~ m' ...._ _._. _ „ 13+00 14-x-00 15-�-DO 16-t00� 17-�-OD 1e -t00 .....—t *00 20.100 2�+00 22+00 °' o ___ ____ o - .» ---- _> 4 2 Z _»__ ___» ____ _.___ 6 2 ____ _»__ 7 _»__ ____ ___» »._.._.._ ____ ___ 8 _»_._ ____ ���I=o W- 4- - _ ._...� _ — _ _ _ - _ ___ __ _ _ _ __ __ ___ _ _ _ _ _ _ _ _ _ _ _ _ _ » � _ __ _ _ _ _ - ___ _ _ _ � w 13 1 — x� __ N N W W V) O + O N a JK + C > N Q\0 L JN - J \0 d ° SEE "CONTROLLER DETAIL" Q Q o �j ? THIS SHEET � Z* J N N Y Ln d Ln 0 N I CONSTRUCT/ON NOTES : 1® INSTALL NEW TYPE 15 POLE SINGLE ARM LIGHTING STANDARD WITH 143W LED. 2® INSTALL NEW TYPE 15S POLE SINGLE ARM LIGHTING STANDARD WITH 143W LEO. ] INSTALL OLDCASTLE B1017 TRAFFIC RATED PULL BOX AT LOCATION AS SHOWN ON PLANS CITY OF BAKERSFIELD, CALIFORNIA Lu J Lu `V CONDUCTOR NOTES: XX REFER TO CAL TRANS STANDARD PLAN 2010 ES -1A. DENOTES STANDARD NOTE AS APPLIED TO CONDUIT RUNS CONDUIT S DES/GNA TED (N)EW or (E)XISTING REFER TO CONDUIT ONLY. SCALE. I "= 40' N F- J I- W W F- V) J r- F- O M NOTE: LIGHT POLES, ANCHOR BOLTS AND LED FIXTURES WILL BE FURNISHED BY THE CITY OF BAKERSFIELD AND INSTALLED BY CONTRACTOR. INSTALL NEW 2" CONDUIT FROM NEW OLDCASTLE B1017 STREET LIGHT BOX TO EXISTING TRAFFIC SIGNAL PULL BOX. FEED STREET LIGHT CIRCUIT THROUGH EXISTING CONDUIT INTO METER PEDESTAL AND INSTALL A NEW 2 POLE 30A CIRCUIT BREAKER ON UN -METERED PANEL SECTION. LABEL -"STREET LIGHTS P STREET" CONDUCTOR SCHEDULE CONDUIT SIZE 2" 2" 1 2" 2" 1 2" 2" 2" 2" c�. 1 2" 2" 1 r s A 011� !b e 6 �.� � m W �,, _ _ » . _ _ » W o LU ~ m' ...._ _._. _ „ 13+00 14-x-00 15-�-DO 16-t00� 17-�-OD 1e -t00 .....—t *00 20.100 2�+00 22+00 °' o ___ ____ o - .» ---- _> 4 2 Z _»__ ___» ____ _.___ 6 2 ____ _»__ 7 _»__ ____ ___» »._.._.._ ____ ___ 8 _»_._ ____ ���I=o W- 4- - _ ._...� _ — _ _ _ - _ ___ __ _ _ _ __ __ ___ _ _ _ _ _ _ _ _ _ _ _ _ _ » � _ __ _ _ _ _ - ___ _ _ _ � w 13 1 — x� __ N N W W V) O + O N a JK + C > N Q\0 L JN - J \0 d ° SEE "CONTROLLER DETAIL" Q Q o �j ? THIS SHEET � Z* J N N Y Ln d Ln 0 N I CONSTRUCT/ON NOTES : 1® INSTALL NEW TYPE 15 POLE SINGLE ARM LIGHTING STANDARD WITH 143W LED. 2® INSTALL NEW TYPE 15S POLE SINGLE ARM LIGHTING STANDARD WITH 143W LEO. ] INSTALL OLDCASTLE B1017 TRAFFIC RATED PULL BOX AT LOCATION AS SHOWN ON PLANS CITY OF BAKERSFIELD, CALIFORNIA Lu J Lu `V CONDUCTOR NOTES: XX REFER TO CAL TRANS STANDARD PLAN 2010 ES -1A. DENOTES STANDARD NOTE AS APPLIED TO CONDUIT RUNS CONDUIT S DES/GNA TED (N)EW or (E)XISTING REFER TO CONDUIT ONLY. SCALE. I "= 40' N F- J I- W W F- V) J r- F- O M NOTE: LIGHT POLES, ANCHOR BOLTS AND LED FIXTURES WILL BE FURNISHED BY THE CITY OF BAKERSFIELD AND INSTALLED BY CONTRACTOR. INSTALL NEW 2" CONDUIT FROM NEW OLDCASTLE B1017 STREET LIGHT BOX TO EXISTING TRAFFIC SIGNAL PULL BOX. FEED STREET LIGHT CIRCUIT THROUGH EXISTING CONDUIT INTO METER PEDESTAL AND INSTALL A NEW 2 POLE 30A CIRCUIT BREAKER ON UN -METERED PANEL SECTION. LABEL -"STREET LIGHTS P STREET" CONDUCTOR SCHEDULE CONDUIT SIZE 2" 2" 1 2" 2" 1 2" 2" 2" 2" 2" 1 2" 2" (E) = EXISTING (N) =NEW N N N N N N N N N N N CONDUCTOR RUN #8 THW CU GROUND 2 I 1 A A 5 0 1 0 0 6 A8 0 0 I 9 10 I I 11 I #6 THW CU 2 2 0 0 0 0 0 2 2 1 2 2 #10 THW CU GROUND 0 0 1 1 I 1 1 1 0 0 0 0— #10 THW CU 0 1 0 2 2 2 1 2 2 1 0 0 0 0 GENERAL NOTES: 1. IF CONTRACTOR REMOVES EXISTING HANDICAP RAMP DURING CONSTRUCTION OPERATIONS, THE RAMP SHALL BE REPLACED WITH A NEW RAMP OF EQUAL TYPE WHICH MEETS CURRENT ADA SPECIFICATIONS. 2. IF CONTRACTOR REMOVES EXISTING SIDEWALK, CURB, OR GUTTER DURING CONSTRUCTION OPERATIONS, THE IMPROVEMENTS SHALL BE REPLACED WITH NEW IMPROVEMENTS OF EQUAL TYPE AND VALUE. J. CONNECT GROUND TO EXISTING 16 CU BARE AT SIGNAL PULL BOX. 4. OPEN TRENCH OR DIRECTIONAL BORING IS ACCEPTABLE. 5. ALL INFORMA TION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS PROVIDED AS BEST POSSIBLE. FINAL RESPONSIBILITY OF VERIFICATION AND ACCURACY IS THE CONTRACTOR'S. 6. LIGHT POLES, ANCHOR BOLTS AND LED FIXTURES WILL BE FURNISHED BY THE CITY OF BAKERSFIELD AND INSTALLED BY CONTRACTOR. ALL OTHER BOXES, CONDUITS, CONDUCTORS, CIRCUIT BREAKERS, FUSES, FUSE HOLDERS, CONCRETE FOUNDATIONS, FORMED CONCRETE WORK, ASPHALT REPAIR, ETC. TO BE FURNISHED AND INSTALLED BY CONTRACTOR. File Nome -Street Li ht Ir PUBLIC WORKS DEPARTMENT Job No.: P5K223 Dote: Jun. 30, 15 v P Stree t Drown: S CL A YTON Engineer: L SUN Checked By.- �_S _ l � J W N ui � F- O 0 + J O N _j a� Q �O C/) ? # CONTROLLER DETAIL qt;) W CORNER - F (NOT TO SCALE) (.'I TY RF('nRn Nn STREET LIGHT IMPROVEMENTS P STREET FROM MING AVENUE TO BELLE TERRACE SHEET NO. 3 OF 3 ' 1 2 3