Loading...
HomeMy WebLinkAbout3.2-458LIST OF DRAWINGS SHEET 1 SHEET 2 TI TLE SHEET SIGNAL PLAN CALTRANS 2002 STANDARD PLANS CITY OO F BA ; ERSFIELDQw TP,tAFFIC SIGNAL AND LIGHTING SYSTEM ES -1 A ES -4B ES- 7B T-11 A20D ES -5B ES -1 B ES -4C ES- 7E T-12 A24A RSP A 88A ES -2C EXIST UNDERGROUND ES -4D ES- 7F ES -13A A24B ES -2E PHONE LINE ES -5C GAS VALVE ES -7M STREET LIGHT W/MAST ARM ES -13A A24C ES -JA CLEAN OUT ES -5E A U TO SCOPE ES -8 ES -13B A 24D ES -3B ES -6A ES -9B A20A A24E ES -JC ES -6B ES -10 A20B ES -4E ES -4A ES- 7A ES -11 A20C ES -5A CITY STANDARDS S-1, S-3, S-6, S-8, S-35, S-41, T-19 CONVENTIONAL SYMBOLS INS TA L LA TION ON S SACRAMENTO PANAMA LANE AT ASHE ROAD '�°�s°° OFRESNO EASEMENT EXIST CURB & GUTTER RIGHT -OF -WA Y EXIST. A. C. FL0WLINE CENTERLINE EXIST. EDGE OF PA VEMENT RAILROAD TRACKS - GUARD RAIL CHAIN LINK FENCE IMPROVEMENTS UTILITY SYMBOLS WATER METER EXIST WA TER LINE EXIST SEWER LINE EXIST GAS LINE EXIST STORM DRAIN EXIST AERIAL EXIST UNDERGROUND LINES POWER LINE EXIST UNDERGROUND EXIST UNDERGROUND TV CABLES PHONE LINE M.H. A MANHOLE F.H. FIRE H YDRAN T P.P. FT W.M. LF Au PO WER POLE 0 WATER METER ' EXISTING MONUMENT W.V. WA TER VAL VE D FUTURE MONUMENT ® G.M. GAS METER S.3 L G.V. STREET LIGHT Da GAS VALVE STREET LIGHT W/MAST ARM BENCHMARK c.o. CLEAN OUT 00- A U TO SCOPE © PRE-EMPTION DEVICE LOCATION MAP NOT TO SCALE REM0 VE TRAFFI C STRIPES AND PA VEMEN T MARKINGS THERM OPLASTI C PA VEMEN T MARKINGS (WHI TE) THERMOPLASTIC DETAIL 9 THERMOPLASTIC DETAIL 40 1610 SQ FT 805 SQ FT 290 LF FT 140 LF FT LOS ANGELES SAN DIEGO STATE OF CALIFORNIA "NO TE. ' THE CONTRACTOR MUST POSSESS THE FOLLOWING VALID LICENSES: ` - r 7 CLASS .4 or C-- >0 e gLIF ORS NO TE. THE CON TRA C TOR SHALL CONTACT THE USA L OCA TOR SERVICE 1-800-642-2444, 48 HOURS PRIOR TO EXCA VA TION. Job No.: T51<1 39 File Path: T51<139 Ashe Pan Sig Full Width2 rec2 Signal Only.dwg QROFESS/ON9 pEAN F'L� w m cy- C 46803 m * Exp. 6-30-07 sj'9TF CIVIL F���\P OF CAb --- --- --- - - - - --- --- --- ----------, i POLE SCHEDULE R/w L1 i I IR Iw NOTES �pFESS/0 P Nq MASTARM SIGNALS SIGNS ®W3-1, W3-3 I W3-1, WJ-3 (I I 1 Install Cit furnished Type 170 Controller and 332 Cabinet assembl . Service shall F� pEAN LOC. STANDARD LIGHTING VEHICLE WALK w -ow PPB ST. NAME SIGN I I I I I( I y yP y R F SIGNALS DONT WALK �' POLE OR MASTARM MOUNTED REMARKS I 1 I I I I be 120v/240v Type W -BF, furnished & installed by Contractor. Pull box in front -►'� 15' (s) MAS c c I I I I I I I of controller shall be #6. Pull box adjacent to P. G. & E. electrical service point m PANAMA LANE (s) I I I I ( 1 shall be P.G.&E. #043459. Other pullboxes shall be #5 unless otherwise noted. REGISTERED Cl GINEER C 46803 O 29-5-129(S) 55' (s) MAS- 4B)c) SP -1- T(c) 08 �6 R3- 4(CA) (c) ©® I i I MAH n e w circular and arrow signal indications shall be LED 12 inch per specifications. * Exp. 6-30-07 I� II I I I I I I I 3 All luminaires shall be cutoff type, 300 W HPSV. All pedestrian indication modules O TYPE 1A(s) TV-2-T(c) SP-1-T(c) 06 08 I I I 7❑ 130 SQFT N I I I I CITY OF BAKERSFIELD I I I I shall be new, LED "UPRAISED HAND" combo "WALKING PERSON", international symbo 1501 TR UX TUN AVENUE q�F Cl V �� 15' (s) MAS(c) I I I I ( 1 types, detailed in the specifications. Ped modules on Poles C,E,F & H shall be BAKERSFIELD, CA 93301 OF CA1-\F ;J 29-5-129(S) 55' s MAS(c) SP-1-T(c) �2 �8 ASHE ROAD (s) ©® I I 7❑ 15 SQFT I I I I I I installed on pole but not activated for future use. () LT-MATc SEE POLE SCHDULE NOTE 2 I ®AII unused, salvaged material shall be delivered, by the contractor, to Wastewater Plant 2 at Mt. Vernon Ave. south of Fw # y. 58. Contact the City's O () () I I I I ( ( Electrical Supervisor 24 hours prior to delivery at (661) 326-3152. 1 5 Location of the standards shall be 5' 1.5m behind the flow line where applicable or as directed by the Engineer at the site. TYPE 1A(s)TV-2-T c SP -1-T c �8 �2 I I I I I I I I I I I I ] 15' (s) SV -1- T(c) PANAMA LANE (s) ❑ ® (I I I I I I 6 O y- 6 Install 4 Cit furnished vechicular video detection cameras on luminaire mast arms as shown on the plans and determined in the field by the O 29-5-129(S) SP-1-T(c) �4 �2 MODIFIED R73-8 CA c SEE POLE SCHDULE NOTE 2 I I I I I I ( 1 Engineer. All wiring shall be internal to poles. Locate camera 3'[.91m from center of luminaire. The video and power cable openings shall be 55 (s) MAS-4B(c) ( ) O ] I I ©30 SQFT I I ( 1 4[1.22m] from center of luminaire. Refer to project specifications. O TYPE 1A(s) TV-2-T(c) SP-1-T(c) 02 04 SEE POLE SCHDULE NOTE 2 SCALE. 1 -20 I ( 1 I) I I I 1 7❑Contractor shall remove pavement markings/striping as indicated on the plan, including sixteen 16 "STOP" and six 6 "AHEAD" ( � () markings by 15 s - _ I 1 I i obliterating a rectangle whose limits are the edge of the word. Contractor shall remove all markings/stripings within new crosswalk area. Under NO 7 29-5-129 S ' O MAS c c I � I circumstances are the letters to be removed individually. Refer to Section 7-1.01 "Order of Work" of the specifications. O () 55'(s) MASc SP-1-T(c) �6 04 ASHE ROAD (s) ©® "I I I N - ( 1 1 I ®Install City -furnished Opticom 711 pre-emption devices where indicated. The Contractor shall furnish and install all cables and mounting hardware g I I (PELCO AB -121). The Opticom 754 phase selector unit will be pre-installed in the cabinet by the City. Contractor shall make internal connections I I I I ( I I ( within cabinet system. Exact hardware mounting placement shall be determined by the Traffic Engineer in the field. Contractor shall provide for an Q TYPE 1A(s) TV -2— r(c) SP -1- T(c) �4 06 SEE POLE SCHDULE NOTE 2 7❑ 15 SQFT I I I I Opticom Technician with J&J Inc. prior to signal turn on. A Opticom Rep. may be contacted 48 hrs prior to turn on at (714) 403-0552. 1 i I I I I I I Contractor shall install City supplied overhead most arm street name signs and mounting brackets. O EXISTING INTERCONNECT 5 R1-1, 14- 7, 1 1 1 PPB �8 CONDUIT TO HARRIS RD 1 1 OM1 -31 I I I 100 Remove and Salvage existing street light. Coordinate with the installation of new luminaires. Disconnect and abandon service conduit per ----0R4-7, IOM1-,l 1 I Cal Trans State Standard Specifications, latest edition. Preserve existing circuit in place. O PPB 06 i I I I I I 1 11 Contractor shall instal/ completely functional City provided Encom 900 MHZ (5100R) Radio systems on Panama Ln at Ashe Rd and Panama Ln 1 j I at Stine Rd. Contractor shall make internal connections in controller cabinet, pull cable from cabinet to antenna, install lightning protector and "1 1 30 SQFT \ I ( 1 type N connector on each end of the coaxial cable. Mountie brackets shall be supplied b the Cit and installed b th POLE SCHEDULE NOTES (S) City Supplied, (C) Contractor Supplied 5 R1-1 © \ I I I 9 PP y y y e Contractor. Exact I I I I 6 \ I hardware placement shall be determined by the Traffic Engineer in the field. 1. New signal poles, 1A poles, signal pole and luminaire mast arms, signal pole and luminaire mast arm connection hardware, and anchor FH I \ I ❑2 Sawcut and remove existing median island curb and nose. Construct new PCC median nose R=2' tangent to the new bolts will be City furnished and delivered by the contractor to the site from the City Airport located at 2000 So Union Ave. Contact City's I ( \ crosswalk er, specifications. Median curb shall b Electrical Supervisor at least 48hrs prior to pick-up. All other equipment shown in the pole schedule, except street name signs shall be W. 2 I P P e painted yellow. Patch excavated area of median removal per COB STD S-6. furnished by the contractor. All pedestrian push buttons shall be ADA and placed at a minimum height of 3'[lm] I I CC \ I bNketmmove and replace existing handicap ramp and curb and gutter to the limists shown on the plans. Replace ramp, curb and gutter per special p 1197 visions and latest Cal Trans State Standard Plan A88A. _ - 2. Pedestrian Heads on poles C, E, F, and H shall be installed and wired but not activated. Pedl heads shall be covered and turned away - - _ from traffic. © R9 -3a 3 W. V. P. ° Remove and Replace Sign Panel as indicated. J. Location of PG&E guy wire located on the southwest corner shall- be verified for mast arm clearance previous to setting pole E. A 7 © Remove Sign indicated. 4. Signal poles on C, D, E, and F shall be set at elevations and offsets provided by the Engineer. H \ O I 6 Sign indicated. W 08 3 OB ° Kli 1 W.V. 07 /nstall thermo lastic stn rn ma km in �c - ©-__� - �8 �8 �b8 P _ O __ WW --- o ---__ -- _ w W o -- o o W - o -- ° R 0 0 - - E _ E E o E W •P F Rl-1----=—�W --- W --_---------------------------------- ---- - �— __ E E �5-------------------- - - _._ -_.--_ __ -_- ----- - -_ ---- -- ®W3-1,W3-3 -------------�� --. ----. -�--- �6 7 170 SQFT E E ------• E--____--------.._______ ©R1-1 E ----' -- O 7 150 SQFT 07 12" CR SSWALK (W ITE) E � --__ 260 S T W M.H. EX1S71NG CONDUITS s DUIT � I 7 25 SQFT, STOP BAR s sI �6 , 7 205 SQFT .... .... .... .... . Q 220 SQFT .. .. .... .... .... .... .... .... .... .... .... .... .... . 7 115 SQFT 7 105 SQFT .. .... .... .... .... .. 8 06 ... ..., EY130 SQFT ... ... .... 7 Q iI �7 DETAIL 40 140 LF f S l T A 10+00 . P A NA,MALN �......... .�. ,.. .�..__.._. �-= IC -I EXISTING EDGE OF PA VEMENT W3-1, W3-3 W W W W — EXISTING IRRIGATION STANDPIPE FUTURE FLOKINE 1-71105 SQFT P.P. CC W EXISTING IRRIGA TION VAL VES 12 13 • - - ---- -- --- -� --- -- - - --------- 46 5 R1-1 . ©R1-1 05 = ----- -_--__--- --- FA -Z W3-3 1 EXISTING Ji TIGA TION ❑7 12" CROSSWALK (WH7TTm) I I EXISTING CONDUI TA --- __ CC �� ANDPIPE 230 SQFT _ 7 DETAIL 9 290 LF -_ M.H. 02 - ---- -- - MA TCH EXISTING \\ W.V. I 7 150 SQFT 02 W \ CC CC 4 EV STI. ti'is E� G(_ 0/_. r"A I EaF_ NT W © R9 -3a I 1 \ 1 7 40 SQFT STOP BAR O P R/w 1 \ W E E 02 P.P.-- CONDUCTOR SCHEDULE NOTES. - - I / 5 R1-1 C - - �2 �7 07` I 9S7 I I 1 I h�17ri'E ,=1_t�l�✓Ll 'E R/w 1. XX Indicates Standard Notes per Cal Trans State Standard Plans ES -1A F I ® R9 -3a O -' 2. Connect existing conduits 4,6,8, & • 15 to new conduit runs. Connect conduits 19 & 20 to existing conduit -CONDUCTOR SCHEDULE as shown on the plan. 9 O I I I ( O ► R 08 , �vI II CONDUIT SIZE 2-J"I 3" 1 2" 2" 3" 3" 3" 3" 3" 2" 2" 2" 2" 3" 2" 2" 2" 3" 3 I I (E) = EXISTINGCONDUCTOR © R9 -3a I Y (N) = NEW RUN 1 AAAAAAA,AAAAAAAAAAAA I DESIGNATION (N) (N) (N) (E) (N) (E) (N) (E) (N) (N) (N) (N) (N) (E) (E) (N) (N) (N) (N) (N) NOTES: 2 2 2 1 2 1 2 2 I G Cr, 28 CONDUCTOR 4 2 1 1 2 2 1 1 °- 9 CONDUCTOR 1 1 1 1 I I 5 CONDUCTOR 1 1 1 1 1 1 I G #10 LIGHTING 2 2 1 2 2 2 2 2 4 I 1 PRE-EMPTION CABLE 4 2 1 1 2 2 1 1 I I 12 [300mmJ LENSES BELDEN #8281 4 2 1 1 2 2 1 1 I I 4—SECTION HEAD DETAIL i I cD #16 VEHICLE DETECTION CAMERA POWER 4 2 2 I .111 KR i NTS 4 4 2 2 g zi #8 VEHICLE DETECTION CAMERA POWER 1 1 1 1 1 1 2 z 12 PAIR 19 AWG INTERCONNECT #4 SERVICE (PRIMARY) 3 #6 SERVICE (SECONDARY) 2 2 R/W CITY OF BAKERSFIELD, CALIFORNIA PUBLIC WORKS DEPARTMENT W 7 115 SQFT 'I II W3-1, W3-3 File Name: T5K139 RL T Drawn: RL T Job No.: T5K139 Engineer: NF Date: 9/10104 Checked By. No. DA TE CONTROLLER N/E CORNER DETAIL 1 "=10' raffic Signal and Lighting Signal Installation on Panama Lane at Ashe Road MODIFIED R73-8(CA) NTS REVISIONS DESCRIP TION SHEET NO. 2 OF 2