HomeMy WebLinkAbout3.2-5590 1 2 LL 3 CONSTRUCT/ON NOTES: QRpFESS/ON Y. F� DEAN �� CONTRACTOR SHALL INSTALL CITY FURNISHED TYPE 170E CONTROLLER AND 332 CAB/NET ASSSEMBL El Rq� Fac FUTURE SERVICE SHALL BE 120v/240v TYPE Ill -BF, FURNISHED AND INSTALLED BY THE CONTRACTOR. PULL BOX IN c•, =o �� 18 INTERCONNECT FRONT OF CONTROLLER SHALL -BE #8. PULL BOX ADJACENT TO PG&E ELECTRICAL SERV/CE PO/NT SHALL BE PG&E #043459. REGISTERED C1 _V1L E GINEER cy_ C 46803 ;:a Exp. 6-30-09 2❑ CONTRACTOR SHALL INSTALL CONDUIT FROM ELECTRICAL SERV/CE PO/NT PGE #043459 PULL BOX TO TYPE 111 -BF SERVICE PEDESTAL. ALL OTHER PULL BOXES SHALL BE #5 UNLESS NOTED OTHERWISE. CITY OF BAKERSFIELD J�9 C/V'� 17 1501 TRUXTUN AVENUE TF " BAKERSFIELD, CA 93301 OF CAS_ ❑3 ALL NEW SIGNAL INDICATIONS SHALL BE 12 LED "RED" "GREEN", AND YELLOW PER SPECIFICATIONS. EXIST/NG STORM I DRAIN SYSTEM ; ® CONTRACTOR SUPPLIED LUM/NARES SHALL BE CUTOFF TYPE, 200 HPSV ON POLES A, C, E, G. REVISIONS 160 i ❑5 ALL PEDESTRIAN /ND/CATION MODULES SHALL BE NEW, LED "UPRAISED HAND" AND "WALKING PERSON" No. DATE DESCRIPTION COMBO, INTERNA TONAL SYMBOL TYPES AS DETAILED IN THE SPECIFICATIONS. i 14 1 6 LOCA TIONS OF THE STANDARDS SHALL BE 4' MIN/MUM BETWEEN FACE OF THE POLE AN THE F W D E L 0 LINE, OR ! 5' BEHIND FLOWLINE WHERE APPLICABLE, OR AS DIRECTED BY THE ENGINEER AT THE SITE, 13 I O ❑ CONTRACTOR SHALL INSTALL CITY -FURNISHED ITERS VIDEO CAMERAS ON LUMINAIRE MAST ARMS AS A15 I SHOWN ON THE PLANS. ALL WIRING SHALL BE INTERNAL TO THE POLES, AND NO COAX/AL SPL/CES WILL BE ! f� ! ALLOWED. LOCATE THE CAMERA 2' FROM THE CENTER OF THE LUMINAIRE. THE VIDEO AND POWER CABLE i OPENINGS SHALL BE 4' FROM THE CENTER OF THE LUM/NA/RE. THE CONTRACTOR SHALL CONTACT JANNA 4 i McKAHNN FROM SYNCHRONEX AT (714) 931- 7631 TWO WEEKS PRIOR TO THE SIGNAL BE/NG TURNED ON. PROGRAMMING SHALL BE COMPLETED BEFORE SIGNAL /S ACTIVATED. ...,�,,;...- 2 . 1.. i O ® CONTRACTOR SHALL INSTALL CITY -FURNISHED OPT/COM 711 PREEMPTION DEV/CES. THE CONTRACTOR SHALL GENERAL NOTES ! FURNISH AND INSTALL CABLES AND MOUNTING HARDWARE (PELCO AB -121). ONE OPTICOM 754 PHASE I 10 SELECTOR UNIT WILL BE INSTALLED IN THE CAB/NET BY THE C/TY. EXACT HARDWARE MOUNT/NG PLACEMENT 1 ALL UNUSED, SALVAGED MATERIAL SHALL BE DELIVERED, BY SHALL BE DETERMINED BY THE TRAFFIC ENGINEER IN THE FIELD. THE CONTRACTOR SHALL PROVIDE AN THE CON TRA C TOR, TO THE WA S TEWA TER PLANT 12 AT MT all ; ON - Sl TE OP TI COM TECHNICIAN WITH J&J INC. CONTACT AN OP TI COM REPRESEN TA T/ VE 48 HOURS PRIOR TO VERNON A VENUE SOUTH OF HIGH WA Y 58. CONTACT THE (j I ' ' 5 TURNING ON SIGNAL A T (714) 321- 7513. i i CITY'S ELECTRICAL SUPER V/SDR, 24 HOURS PR/OR TO i 4 ' I.. _ __ 9 REMOVE EXISTING STREET LIGHT AND RETURN CITY CORPORA TION YARD LOCA TED A T MT. VERNON AVE. ui DELIVERY AT (661) J26-3152. B 2 w ❑ (661)-326-3724. O ; m 6 SCALE. LL_ 2 ALL UTILITY LOCATIONS SHOWN ARE APPROXIMATE ONLY, AND 3 i �� �', = REPRESENT THE BEST INFORMA TION SUPPLIED BY THE VARIOUS 2 ' 1 "=20' o UTILITY COMPANIES. FINAL RESPONSIBILITY FOR LOCATING H �� �� PO C I UTILITIES IN THE FIELD IS THE CONTRACTOR'S. - 7 p WEST HALF OF ! OT 29 OS R TRACT BERKSHIRE EA T A� O------------------------ ------ ------------------------------ ------ -------------- -- C RS 08 I P08 ! -- -------------------------------------------------------------------------------------- R/W LOCA TION OF TRAFFIC SIGNAL --------------------------------------------------------------------------------------------------------------------------- BASED ON FUTURE CURB/GUTTER ❑ A ! i SIDEWALK IMPROVEMENTS BY ----------------------------------------------- A R o -- - - O I r 8 - _ • p 0 12 08 L ! a a a a a a a a a RAISED MED/AlVISLAND ............ ......... _..... _.................. x _..__.._.._.._.._.. _.. - ----....._....... ..........................._......- I N ) 9 20 ---------------+------------------------ 04.-- -- i s 21 22 23 d +-------------- --- - 07 ryt................................ ---------------+---- - - ------------+--------------------------------+----------------------•------------------- ._ ----- + - - - ------------------------------•------- + ------------------------------------------ + + - I ----------- --- 00 12 ! I I � + O N I x..._..._. _.................._. ,.------------------ _....._- - -- - _....__._RAISED_-MED/AN ISLAND i I * 0 ° POWER POINT OF -- PLACE TYPE 5 PULL i i 6 BOX A T STA 16+00 CONNECTION � � � i = i >; --------------------------------------._._..... (780 LF FROM STREET A-------------------------------------------------------------------------T,.......------------------- i i � ❑ a I i i INTERSECTION) - - 7i PO4 10 I C _-__—___ --- -- ------------------------------------ - --- i PO4 ' i i , f 0 --------------- -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- - -------------------------- --------------------- ------------- ----------------- ------------------------------------ �, 1 2 -- _--- - -,03 -...-.... ------ J I • - i Y , 04 , �` 06 - 06 i i 0 _ P02 t E i o EX. BLOCK WALL :''01 P06 i ✓ N LANDSCAPE AREA ti 8 N I v �_ POLE SCHEDULE 0 1.7 MASTARM SIGNALS SIGNS 9 �2' 9 �� 3 LOC. STANDARD LIGHTING WALK W -D PPB ST. NAME S/GN i , ° SIGNALS VEHICLE DON'T WA 0 :0' POLE OR MASTARM MOUNTED REMARKS 0 15' SV -1- T SP_ 1- T MONITOR STREET b `v A 29-5-100 MAS 08 06 a SHANNON STREET ❑7 c 55' i ���� �� o LT -MAT Cj I B lA TV -2- T SP -1- T 06 08 I j\� 0 15' SV -1-T ° C 26-4-100 MAS SP -1- T 02 08 HOSKING A VENUE ❑ ® i = i ! 45' (S) L T -MAT iLO N 1A TV -2- T SP -1- T 08 02 Y D i ~ ' SV- - T E 29-5-100 15 MAS SP -1- T 04 02 a MONITOR STREET D z 55' L T -MAT SHANNON STREETr-> CL z F lA TV -2- T SP -1- T 02 04 CD i z 15' V -1- w �' 26-4-100 MAS SP -1- T 04 06 HOSKING A VENUE ❑ ® i 0 45' (S) T -MA T o i % H lA TV -2- T SP -1- T i Y i File Nome: T8025-2004 Drawn: JAFLORES TRAFFIC SIGNAL AND LIGHTING SYSTEM INSTALLATION AT THE INTERSECTION O SHEET NO. CITY OF BAKERSFIELD, CALIFORNIA PUBLIC WORKS DEPARTMENT Job No.: TSK125 Engineer: JAF/NG Date: Oct. 21, 08 Checked By � HOSKING AVENUE AT MONITOR ST 2 OF 3 0 1 2 3 CONDUCTOR S CHED UL E CONDUIT SIZE 2-3" 2-3" 3" 3" 3" 3" 3" 3" 2" 2" 2" 3" 2" 2" 2" 2" 2" 2" (E) =EXISTING CONDUCTOR (N) =NEW RUN 1 2 3 4 5 6 7 8 9 10 11 1 13 14 1 1 1 18 — DESIGNATION (N) (N) (N) (E) (N) (N) (N) (E) (N) (N) (N) (E) (N) (N) (N) (N) (N) (N) — 28 CONDUCTOR 4 4 1 3 2 2 1 1 — — — — — — — — — — 9CONDUCTOR- 5CONDUCTOR#10 LIGHTING — 4 2 2 2 2 2 2 — — — — 4 — 4 — — — PRE-EMPTION CABLE 4 4 1 3 2 2 1 1 — — — — — — — — — — RG59/U VEHICLE DETECTION 4 4 1 3 2 2 1 1 — — — — — — — — — — #16 VEHICLE DETECTION CAMERA POWER — 8 2 6 4 4 2 2 — — — — 8 8 — — — — #8 COMMON GROUND — 1 1 1 1 1 1 1— #4 SERVICE PRIMARY — — — — — — — — — 3 3 3 — — — — — — #6 SERVICE SECONDARY — — — — — — — — — — — — 2 2 — — — — CONDUITS 16-18 SHALL BE LEFT BLANK W/ PULL ROPES INSTALLED FOR FUTURE INTERCONNECT CONDUCTOR CABLE