Loading...
HomeMy WebLinkAbout3.2-561LIST OF DRA WINGS SHEET f T/TLE SHEET SHEET 2 TRAFFIC SIGNAL SHEET & STRIPING X W - OH - TV -0 M.H. P.P. Au CITY OF DEPARTME 3AK RSF I NT of PUBLIC WORKS ESD TRAFF/C SIGN, IL AND L/GTING HSYSTEM INS TA L LA TION A T THE IN TERSEC TION OF OLD RIVER ROAD AND WH/TE OAK DR/VE CITY STANDARDS: ST -1, ST -14, ST -f9, T- 12, T- 19 STATE STANDARDS ES -1A, ES -18, ES -2C, ES -2E, ES -3A, ES -38, ES -3C ES -4A, ES -46, ES -4C, ES -4D, ES -4E, ES -5A, ES -56, ES -5C ES -50, ES -6A, ES -7D, ES -7E, ES -7F, ES -7G, ES -8, ES -10, ES -11 A20A, A208, A20C, A200, A24A, A248, A24E CONVENTIONAL SYMBOLS EASEMENT EXIST. CURB & GUTTER RIGH T -OF- WA Y EXIST, A. C. FL 0KINE CENTERLINE 'h '�' '�' EXIST, EDGE OF PA VEMENT RAILROAD TRACKS GUARD RAIL CHAIN LINK FENCE IMPROVEMENTS UTILITY SYMBOLS EXIST WA TER LINE EXIST GAS LINE EXIST AERIAL LINES EX/S T UNDERGROUND TV CABLES EXIST OIL LINE MANHOLE POWER POLE FO EXIST/NG MONUMENT � FUTURE MONUMENT S.L. STREET LIGHT STREET LIGHT W/MAST ARM C.O. CLEAN OUT J SD E T FO (F.H. �:)Jr FIRE HYDRANT EXIST SEWER LINE EXIST STORM DRAIN EXIST UNDERGROUND POWER LINE EXIS T UNDERGROUND PHONE LINE EXIST FIBER OPTIC LINE W.M. O WA TER METER W.V. WATER VALVE G.M. ® GAS METER G.V. Dd GAS VAL VE {� BENCHMARK III&- AU TO SCOPE © PRE-EMPTION DEVICE 4 . MING AVENUE I I PROJECT � LOCA TION �I WHI TE LANE LOCATION. MAP NO T TO SCALE I FINAL PAY QUANTITIES I Remove Striping and Pavement Markings 495 SQFT Thermoplastic Pavement Markings 581 SQFT Job No.: T7K125 File Path: K: \LDD-ENGINEERING\T7K125-OLD RIVER -WHITE OAK-SIGNAL\DWG File Name: T7K125.DWG N j 0 0 uj I Z Q 0 o' I W 0� J 0 LL STATE OF CALIFORNIA 0 Z 0 NO TE: U THE CON TRA C TOR MUST POSSESS THE FOL L 0 W/NG ui VALID LICENSES: CLASS A OR C 10 z w NO TE: Z THE CON TRA C TOR SHALL CONTACT THE USA L OCA TOR SERVICE 1-800-642-2444, 48 HOURS PRIOR TO EXCA VA T/ON, Z U, 0 Q J J Q z e APPRC>VHn OV rrenn RAUL 0. ROJAS, R.C.E. 39800, EXPIRES 12-31-09 DATE ` PUBLIC WORKS DIRECTOR J 00, PRoEary �/q</F APPROVAL RECOMMENDED BY: C 46803 'J * Exp. 6-30-09 * - //25 O SI T PUBLIC WORKS DIRECTOR DIATE rr`nn c I V 1 OF CALF (� CIVIL ENGINEER IV - DESIGfV ENGINEERING DATE 15 - 5(1 r�¢a Z TRAFFIC ENGINEERING DATE TRAFF/C SIGNAL AND LIGHT/NG SYSTEM N 0 1 INSTALLA770N AT THE INTERSEC770N OF of OLD RIVER ROAD AND WHIOAK DRIVE SH E TE TS 0 1 2 3 OO ti O J CL Q rn N CIO0 0 N fir ot O POLE SCHEDULE NO TES o QRpFESS5101V I I I Qlnstoll City furnished Type 170 Controller and 332 Cabinet assembly. Service shall be 120v/240v �� DEAN R F MAST ARM SIGNALS SIGNS � � � I - �• o � � LOC. STANDARD I TIN WALK W -Ow T. N SIGN REMARKS Type 111 -BF, furnished & installed by Contractor. Type Ill -BF Pedestal shall be no closer than 20' ��, z SIGNALS VEHICLE DONT WALK 0 0 MAST ARM MOUNTED t0 the controller cabinet. Pull box in front Of controller shall be #6. Contractor shall install pull box W Q c SV- 1-T C I REGISTERED Cl VIL _EN INEER C 46803 OA 29-5-100 f5, (s) MAS (C) 02 04 WH/TE OAK OR/VE I #043459 Od jacen t to P.G. & E. electrical service point. (S) 50 (s) MAS (C) SP-1-T(C) (C) (C) 11 10 6J3U 6J2L 6J2U 2 Contractor shall install conduit from electrical service point to pull box. All other ullboxes shall be * Exp, 6-30-09 LT -MAT (S) I LOO. THE LIMIT LINE ❑ 5 unless otherwise noted, p p p CITY OF BAKERSFIELD s © IA (S) TV -2- T (C) SP- f - T (C) 04 02 WHITE OAK DRIVE # 501 TRUX TUN A VENUE �qTF Ct V j� (c) (C) 3❑A// new circular and arrow signal indications shall be 12 inch "LED" Red, Green and Yellow BAKERSFIELD, CA 93301 OF CAS_ Indicotions per specificotions. REVISIONS O 15' (s) Sv- l- T (c) �2 OLD RIVER ROAD I C 19-4-100 MAS -4B (C) 11 10 R73-4 (C) 4 Luminaires shall be cutoff type, 200 W HPSV on all poles. (S) 30' (S) (S) ❑ No. DA TE DESCRIPTION 02 ❑All pedestrian indication modules shall be new, LED "UPRAISED HAND" combo "WALK/NG PERSON'; O 1A (S) Tv -2-T (c) SP-1-Tlcl (C) IL 1 11 international symbol types, detailed in the specificotions. All unused, salvaged, materia/ shall be SV -1-r c delivered by the contractor, to Wastewater Pont 12 at Mt. Vernon Ave. south of Fwy. 58. Contact E 29-5-100 15. (S) MAS (c) 06 wH17E OAK DRIVE the City's Electrical Supervisor 24 hours prior to delivery at (661) 326-3152. (S) 55 (S) MA T (C) SP- f - T (c) fQ (C) (S) 11 10 ©Location of the standards shall be 5' behind the flow line where opplicoble or as directed by the OF1A (S) Tv -2-T (C) 06 I Engineer at the site. Sv-1-T (C) 7 All utility locations shown ore opproximote only and represent the best information supplied by the 3 / / © 19-4-100 l00 f5' (S) MAS -48 (c) Sp- f-T(C) Qj4 !( OLD RIVER ROAD 11 10 R3-4 (C) various utility companies. Final responsibilty for locating utilities in the field is the Contractors. (s) 25' (s) (c) (c) (S) EXISTING (6 04 INTERCONNECT ®Contractor shall remove pavement morkings/striping as indicated on the plan, including three (3) (c) (c) 9 9 9 4 / / H IA(s) Tv -2- T (c) SP- f- T(C) I "STOP" markings by obliterotin a rectangle whose limits ore the edge of each word. Under NO O I20' LANDSCAPE circumstances are the letters to be removed individually. (S) City Supplied, (C) Controctor Supplied EASEMENT ❑Remove and salvage existing street light luminaires on the northeast and southwest corner. Coordinate with the instollotion of new luminaires. Disconnect i and abandon service conduit per Co/Trons State Standard Specificotions, latest edition Section 86-7. Preserve existing circuit in place. POLE SCHEDULE NOTES Instoll City -furnished Opticom 711 pre-emption devices where indicoted. The Contractor shall furnish and install all cables and mounting hardware (PELCO New signal poles, 1A poles, signal pole and luminaire most arms, signal pole and luminaire most arm connection hardware, I I I -1 1 Th - / internal connections and ochor bolts will be City furnished and delivered by the contractor to the site from the City Storage Yard south of I AB 2 ). a Opticom 752 phase Selector units will be pre /nstolled in the cobinet by the City. Contractor shall make within Cabinet Hwy 58 across from the City's Green Waste Facility located at 2600 So Mt Vernon Ave. Contact City's Electrical Supervisior I system, refer to wiring detoil. Exact hardware mounting placement Shall be determined by the Traffic Engineer in the field. Contractor shall provide for on at (661) 326-3152 at least 48hrs prior to pick-up. All other equipment shown in the pole schedule, except street name, pticom Technician with DDL Inc. prior to Signal turn on. A Opticom Rep. may be contacted 48 hrs prior to turn on at (714) 321-7513. signs, shall be furnished by the contractor. Al/ pedestrian push buttons shall be ADA per Standard Specifications. 05 11 Contractor Shall install City supplied sign mounting brackets and overhead most arm Street name Signs. (SEE POLE SCHEDULE) 12 Remove sign indicated. I13 App/ thermoplastic pavement markings and Striping Detoils indicated on plans per specifications. � / ❑ Y P P 9 P 9 P P 2 EXISTING 72» CONCRETE 11 6J4L 6J4U 6J4U I I " CULVERT CROSSINGS 11 U 14 Remove Existing and Conflicting Striping within the intersection per Specifications. � � 15 Type C loops shall be 6 x50' except as noted otherwise. Circular loops shall be 6' diameter. Right -Turn loops shall be 6`x15' Detector loops and lead-ins within 8 feet of the curb f/owline shall be a minimum of 1.5 inches below the surface of the poving. Loops shall be installed only between the hours of 8:30AM-4:30PM. All loops shall be located in the field by the Engineer. Detector loops shall be centered on their respective /ones. I 16 Remove and install handicap romps and curb & gutter returns on all four corners per RSA88A, Type C . Asphalt concrete tie in shall be a minimum 2' width at LEGEND ❑rep/aced curb & gutter per latest revision. [ 5 22 17 Existing 12-Poir interconnect runs from the northeast corner of Ming Ave and 0/d River Rood to the northwest corner of Old River Rood and Ridge Oak Drive. CONSTRUCT HANDICAP RAMPS I 10 9 Contractor shall remove existing interconnect conductor from the controller cobinet at Old River Rood and Ridge Oak Drive and install Conductor in new Cabinet j" (SEE NOTE # 16 FOR TYPE) I at the northeast corner of O/d River Rood and White Oak Drive. Contractor shall install new interconnect conductor from 0/d River Rood and Ridge Oak Drive to a new controller cabinet at the northeast corner of Old River Rood and White Oak Drive. CONDUITINTERCEPWITHIS SNILLBOX INT ONNEC A 4 21 18 INSTALL NSW INTE CO N T CABLE I `� 12 2 IN XISTIN I TER ON E CONDUIT H See Controller Cabinet 02 02 P �:�" B � Detail Below THE CABLES ALL BE COTINUOUS FRO 6 16 P - -- — — CA INET TO ABI ET. NO PLICE WILL R/w } 16 r: �— BE�ALLOWED. 06 fi 6#4 3 8 180 SOF T ---- _ PS84 56 SOFT wk� 5 I 14 14 112 SQFT 04 IMMM 8 90 SOFT SCALE: 1"-20' I W ITE OAK DRIVE ,�_ 416U � 14 57 SOFT � � o Q--..-..-. 0 - 3,16 _ 0 - 13 CROSSWALK 472 SOFT TYPE VI ARROWS 30 SOFT 27 SOFT: 13 X03 12 c/o3J6L 6' ( I 0 W 16 0 G CONDUCTOR NOTES: 03 •. 13 LIMIT LINE 52 SOFT - _ 0 F n I. Conduits designated (N)ew or (E)xist refer to conduits only, all conductors shq l ! $ : . new except where noted as (Ex.), i i `��'r 6 06 �d1 5'WATERLINE EASEMENT p 9 2. All conduits shall be bored under existing roadway. No open cutting or i 126 — — — ' trenching is allowed along Old River Rood or White Oak Drive. ti. FFPO2 :';'• C C J. Install new interconnect cable in existing conduit except for conduits 20, 21, and 22. 8 CE ' '' 's ` � RID GE OAK D i VE � The cable shall be continuous from cabinet to cabinet No splices will be allowed. 16 13 CONDUC TOR SCHEDULE `" D » » » » » » » » » » » » » » » » » » » CONTROLLER DETAIL NUI l -3 3 -3 4 3 3 3 3 2 2 2 3 3 2 2 3 3 3 3 3 3 3 I CONDUCTOR RU &&A&&&AAAAA®AAAAAAA AAAN I I E CORNER (N)EW OR E X/ST. N N N N N N N N N N N N N N N N N N N N N N I I 20 / R 17 NOTES 3 3 3 _ _ — (NOT TO SCALE) 28 CONDUCTOR 4 4 3 2 2 1 1 1 ---- - -- 9 CONDUCTOR 1 1 1 1 14 Tv� 5 CONDUCTOR 10 LIGHTING 4 2 2 2 2 2 2 4 4 I 5 1 1 PRE- EMPTION CABLE 4 4 3 2 2 f 1 1 --- 01 T TOR EXISTING 4051 L G DE EC 0 f 1 f 1 1 • ► "" � 19 �� 02 DETECTOR 5 5 5 5 5 3 INTERCONNECT 15 03 DETECTOR 2 2 2 2 2 2 1 1 1G 04 DETECTOR 3 2 1 ` ~ /� B 05 DETECTOR f 1 1 1 1� 06 DETECTOR 5 5 5 5 1 5 3 4 -SECTION HEAD DETAIL TOTAL DETECTORS 17 2 15 8 8 2 2 1 1 1 6 1 3 6 6 6 3 I (NTS) E # 4 SERVICE PRIMARY 3 LOOPS ARE 405' B K MAS 4B # 6 SERVICE SECONDARY 2 2 FROM THE LIMIT LI ONITE 0 K DRI 21 212L 213U 12 PAIR 19 AWG INTERCONNECT 2 2—,2 File Name: T7K125 Drawn: N.Grewa/ TRAFFIC SIGNAL AND LIGHTING SYSTEM INSTALLATION AT THE SHEET NO. CITY OF BAKERSFIELD, CALIFORNIA PUBLIC WORKS DEPARTMENT Job No.: T7K125 Engineer: N. Grewal Date: JAN, 2008 Checked BY t�� INTERSECTION OF OLD RIVER ROAD AND WHITE OAK DRIVE 2 OF 2