Loading...
HomeMy WebLinkAbout#643 Bakersfield VR Setup 5-16-18+=============================================================+ | Monitoring System Report using Report Utility | | Version: Version 6.0.0.100 | +=============================================================+ Connected on PC Port: COM4 Settings: 1200 Odd 7, 1 Connect Time/Date from PC Clock: Wednesday, May 16, 2018 - 4:02:15 PM Connect Date from Monitoring System: 180516 Connect Time from Monitoring System Clock: 16:04 Site Label: 279395 COSTCO 643 4900 PANAMA LANE BAKERSFIELD, CA ============================ Request: 1 - 200 - Site Location Request Source: Monitor System Configuration Requests - Line: 1 _________________________ 200 279395 COSTCO 643 4900 PANAMA LANE BAKERSFIELD, CA MAY 16, 2018 4:04 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 Unleaded 21167 77.00 0.0 73.9 8876 2 Unleaded 21177 77.05 0.0 73.8 8866 3 Premium 19643 71.36 0.0 73.7 10440 4 Additive 758 23.64 77.0 756 ============================ Request: 2 - I90500 - System Revision Level Request Source: Monitor System Configuration Requests - Line: 2 _________________________ I90500 MAY 16, 2018 4:04 PM SOFTWARE REVISION LEVEL VERSION 333.04 SOFTWARE# 346333-100-E CREATED - 13.06.07.08.25 S-MODULE# 330160-164-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS BIR ISD/APM PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV ============================ Request: 3 - I50500 - System Type & language Request Source: Monitor System Configuration Requests - Line: 3 _________________________ I50500 MAY 16, 2018 4:04 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM ============================ Request: 4 - I50201 - Shift Start Time 1 Request Source: Monitor System Configuration Requests - Line: 4 _________________________ I50201 MAY 16, 2018 4:04 PM SHIFT TIME 1 : DISABLED ============================ Request: 5 - I50202 - Shift Start Time 2 Request Source: Monitor System Configuration Requests - Line: 5 _________________________ I50202 MAY 16, 2018 4:04 PM SHIFT TIME 2 : DISABLED ============================ Request: 6 - I50203 - Shift Start Time 3 Request Source: Monitor System Configuration Requests - Line: 6 _________________________ I50203 MAY 16, 2018 4:04 PM SHIFT TIME 3 : DISABLED ============================ Request: 7 - I50204 - Shift Start Time 4 Request Source: Monitor System Configuration Requests - Line: 7 _________________________ I50204 MAY 16, 2018 4:04 PM SHIFT TIME 4 : DISABLED ============================ Request: 8 - I54600 - Tank Periodic Test Needed Warning Request Source: Monitor System Configuration Requests - Line: 8 _________________________ I54600 MAY 16, 2018 4:04 PM TANK PER TST NEEDED WRN: DISABLED ============================ Request: 9 - I54900 - Tank Annual Test Needed Warning Request Source: Monitor System Configuration Requests - Line: 9 _________________________ I54900 MAY 16, 2018 4:05 PM TANK ANN TST NEEDED WRN: DISABLED ============================ Request: 10 - I55300 - Line Re-Enable Method Request Source: Monitor System Configuration Requests - Line: 10 _________________________ I55300 MAY 16, 2018 4:05 PM LINE RE-ENABLE METHOD PASS LINE TEST ============================ Request: 11 - I55600 - Line periodic Test Needed Warning Request Source: Monitor System Configuration Requests - Line: 11 _________________________ I55600 MAY 16, 2018 4:05 PM LINE PER TST NEEDED WRN: DISABLED ============================ Request: 12 - I55900 - Line Annual Test Needed Warning Request Source: Monitor System Configuration Requests - Line: 12 _________________________ I55900 MAY 16, 2018 4:05 PM LINE ANN TST NEEDED WRN: DISABLED ============================ Request: 13 - I50D00 - Print Temperature Compensation Request Source: Monitor System Configuration Requests - Line: 13 _________________________ I50D00 MAY 16, 2018 4:05 PM PRINT TC VOLUMES ENABLED ============================ Request: 14 - I50E00 - Temperature Compensation Value Request Source: Monitor System Configuration Requests - Line: 14 _________________________ I50E00 MAY 16, 2018 4:05 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 ============================ Request: 15 - I60B00 - Tank Stick Height Function Enable Request Source: Monitor System Configuration Requests - Line: 15 _________________________ I60B00 MAY 16, 2018 4:05 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED ============================ Request: 16 - I51400 - H-Protocol Height-Volume Format Request Source: Monitor System Configuration Requests - Line: 16 _________________________ I51400 MAY 16, 2018 4:05 PM H-PROTOCOL DATA FORMAT HEIGHT ============================ Request: 17 - I51A01 - Auto Daylight Saving Time Request Source: Monitor System Configuration Requests - Line: 17 _________________________ I51A01 MAY 16, 2018 4:05 PM DAYLIGHT SAVING TIME DISABLED ============================ Request: 18 - I51B00 - Start-End Daylight Saving Time Request Source: Monitor System Configuration Requests - Line: 18 _________________________ I51B00 MAY 16, 2018 4:05 PM ============================ Request: 19 - I51600 - Re-Direct Local Printout Request Source: Monitor System Configuration Requests - Line: 19 _________________________ I51600 MAY 16, 2018 4:05 PM RE-DIRECT LOCAL PRINTOUT DISABLED ============================ Request: 20 - I50400 - RS-232 Security Code Request Source: Monitor System Configuration Requests - Line: 20 _________________________ I50400 MAY 16, 2018 4:05 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED ============================ Request: 21 - I21900 - Tank Chart Security Request Source: Monitor System Configuration Requests - Line: 21 _________________________ I21900 MAY 16, 2018 4:05 PM TANK CHART SECURITY DISABLED ============================ Request: 22 - I5BD00 - Custom Alarms Request Source: Monitor System Configuration Requests - Line: 22 _________________________ I5BD00 MAY 16, 2018 4:05 PM CUSTOM ALARM LABELS DISABLED ============================ Request: 23 - I56000 - Mass Density Enable-Disable Request Source: Monitor System Configuration Requests - Line: 23 _________________________ I56000 MAY 16, 2018 4:05 PM MASS/DENSITY DISABLED ============================ Request: 24 - I88101 - Comm Port 1 Settings Request Source: Monitor System Configuration Requests - Line: 24 _________________________ I88101 MAY 16, 2018 4:05 PM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : ****** ============================ Request: 25 - I88102 - Comm Port 2 Settings Request Source: Monitor System Configuration Requests - Line: 25 _________________________ I88102 MAY 16, 2018 4:05 PM PORT SETTINGS: COMM BOARD : 2 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : ****** DTR NORMAL STATE: HIGH ============================ Request: 26 - I88103 - Comm Port 3 Settings Request Source: Monitor System Configuration Requests - Line: 26 _________________________ I88103 MAY 16, 2018 4:05 PM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 1200 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : ****** ============================ Request: 27 - I88104 - Comm Port 4 Settings Request Source: Monitor System Configuration Requests - Line: 27 _________________________ I88104 MAY 16, 2018 4:05 PM ============================ Request: 28 - I88105 - Comm Port 5 Settings Request Source: Monitor System Configuration Requests - Line: 28 _________________________ I88105 MAY 16, 2018 4:05 PM ============================ Request: 29 - I88106 - Comm Port 6 Settings Request Source: Monitor System Configuration Requests - Line: 29 _________________________ I88106 MAY 16, 2018 4:05 PM ============================ Request: 30 - I52000 - Receiver Auto Dial Type and Start Time Request Source: Monitor System Configuration Requests - Line: 30 _________________________ I52000 MAY 16, 2018 4:05 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE MAY 16, 2018 DISABLED 2 ON DATE MAY 16, 2018 DISABLED 3 ON DATE MAY 16, 2018 DISABLED 4 ON DATE MAY 16, 2018 DISABLED 5 ON DATE MAY 16, 2018 DISABLED 6 ON DATE MAY 16, 2018 DISABLED 7 ON DATE MAY 16, 2018 DISABLED 8 VEEDER-ROOT FMS ON DATE MAY 16, 2018 DISABLED ============================ Request: 31 - I60100 - Tank Configuration Request Source: Monitor System Configuration Requests - Line: 31 _________________________ I60100 MAY 16, 2018 4:05 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 Unleaded ON 2 Unleaded ON 3 Premium ON 4 Additive ON ============================ Request: 32 - I60200 - Tank Product Label Request Source: Monitor System Configuration Requests - Line: 32 _________________________ I60200 MAY 16, 2018 4:05 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 Unleaded 2 Unleaded 3 Premium 4 Additive ============================ Request: 33 - I60300 - Tank Product Code Request Source: Monitor System Configuration Requests - Line: 33 _________________________ I60300 MAY 16, 2018 4:05 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 Unleaded 1 2 Unleaded 1 3 Premium 2 4 Additive 3 ============================ Request: 34 - I60900 - Tank Thermal Expansion Coefficient Request Source: Monitor System Configuration Requests - Line: 34 _________________________ I60900 MAY 16, 2018 4:05 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 Unleaded 0.000700 2 Unleaded 0.000700 3 Premium 0.000700 4 Additive 0.000405 ============================ Request: 35 - I60700 - Tank Diameter Request Source: Monitor System Configuration Requests - Line: 35 _________________________ I60700 MAY 16, 2018 4:05 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 Unleaded 118.25 2 Unleaded 118.25 3 Premium 118.16 4 Additive 47.50 ============================ Request: 36 - I60A00 - Tank Full Volume Request Source: Monitor System Configuration Requests - Line: 36 _________________________ I60A00 MAY 16, 2018 4:05 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 Unleaded 20 PTS 30043 2 Unleaded 20 PTS 30043 3 Premium 20 PTS 30083 4 Additive 4 PTS 1514 ============================ Request: 37 - I60400 - Tank 1 Point Full Volume Height Request Source: Monitor System Configuration Requests - Line: 37 _________________________ I60400 MAY 16, 2018 4:05 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 Unleaded 30043 2 Unleaded 30043 3 Premium 30083 4 Additive 1514 ============================ Request: 38 - I60500 - Tank 4 Point Full, 3/4, 1/2. 1/4 Volumes Request Source: Monitor System Configuration Requests - Line: 38 _________________________ I60500 MAY 16, 2018 4:05 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 Unleaded 30043 24619 15381 6034 2 Unleaded 30043 24614 15374 6028 3 Premium 30083 24833 15630 6251 4 Additive 1514 1220 762 299 ============================ Request: 39 - I60600 - Tank 20 Point Full, 95%, 90%, ...volumes Request Source: Monitor System Configuration Requests - Line: 39 _________________________ I60600 MAY 16, 2018 4:05 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 Unleaded 30043 29660 28767 27584 26185 24619 22922 21124 19252 17330 15381 13428 11493 9600 7771 6034 4416 2951 1681 669 2 Unleaded 30043 29658 28764 27580 26181 24614 22917 21118 19246 17323 15374 13421 11487 9594 7766 6028 4411 2946 1678 667 3 Premium 30083 29778 28922 27764 26384 24833 23148 21360 19494 17577 15630 13677 11740 9840 8002 6251 4615 3127 1829 777 4 Additive 1514 0 0 0 0 1220 0 0 0 0 762 0 0 0 0 299 0 0 0 0 ============================ Request: 40 - I61500 - BIR Meter Data Present Request Source: Monitor System Configuration Requests - Line: 40 _________________________ I61500 MAY 16, 2018 4:06 PM TANK PRODUCT LABEL METER DATA 1 Unleaded YES 2 Unleaded YES 3 Premium YES 4 Additive YES ============================ Request: 41 - I62F00 - Mag Probe Float Size Request Source: Monitor System Configuration Requests - Line: 41 _________________________ I62F00 MAY 16, 2018 4:06 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 Unleaded 4.0 IN. 2 Unleaded 4.0 IN. 3 Premium 4.0 IN. 4 Additive 4.0 IN. ============================ Request: 42 - I62700 - Tank Height Water warning limit Request Source: Monitor System Configuration Requests - Line: 42 _________________________ I62700 MAY 16, 2018 4:06 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 Unleaded 1.0 2 Unleaded 1.0 3 Premium 1.0 ============================ Request: 43 - I64200 - Tank Water Filter Limit Request Source: Monitor System Configuration Requests - Line: 43 _________________________ I64200 MAY 16, 2018 4:06 PM WATER ALARM FILTER TANK PRODUCT LABEL 1 Unleaded LOW 2 Unleaded LOW 3 Premium LOW ============================ Request: 44 - I62400 - Tank High Water Level Limit Request Source: Monitor System Configuration Requests - Line: 44 _________________________ I62400 MAY 16, 2018 4:06 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 Unleaded 1.5 2 Unleaded 1.5 3 Premium 1.5 ============================ Request: 45 - I62800 - Tank Maximum Volume Limit Request Source: Monitor System Configuration Requests - Line: 45 _________________________ I62800 MAY 16, 2018 4:06 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 30043 2 Unleaded 30043 3 Premium 30083 4 Additive 1514 ============================ Request: 46 - I62300 - Tank Overfill Level limit Request Source: Monitor System Configuration Requests - Line: 46 _________________________ I62300 MAY 16, 2018 4:06 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 27039 2 Unleaded 27039 3 Premium 27075 4 Additive 1363 ============================ Request: 47 - I62200 - Tank High Level Limit Request Source: Monitor System Configuration Requests - Line: 47 _________________________ I62200 MAY 16, 2018 4:06 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 28541 2 Unleaded 28541 3 Premium 28579 4 Additive 1438 ============================ Request: 48 - I62900 - Tank Delivery Required limit Request Source: Monitor System Configuration Requests - Line: 48 _________________________ I62900 MAY 16, 2018 4:06 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 4506 2 Unleaded 4506 3 Premium 4512 4 Additive 150 ============================ Request: 49 - I62100 - Tank Low Level Limit Request Source: Monitor System Configuration Requests - Line: 49 _________________________ I62100 MAY 16, 2018 4:06 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 800 2 Unleaded 800 3 Premium 800 4 Additive 114 ============================ Request: 50 - I62600 - Tank Leak Alarm Limit Request Source: Monitor System Configuration Requests - Line: 50 _________________________ I62600 MAY 16, 2018 4:06 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 8 2 Unleaded 8 3 Premium 8 4 Additive 99 ============================ Request: 51 - I62500 - Tank Sudden Loss Limit Request Source: Monitor System Configuration Requests - Line: 51 _________________________ I62500 MAY 16, 2018 4:06 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 25 2 Unleaded 25 3 Premium 25 4 Additive 99 ============================ Request: 52 - I60800 - Tank Tilt Request Source: Monitor System Configuration Requests - Line: 52 _________________________ I60800 MAY 16, 2018 4:06 PM TANK TILT TANK PRODUCT LABEL INCHES 1 Unleaded 0.00 2 Unleaded 0.00 3 Premium 0.00 4 Additive 0.00 ============================ Request: 53 - I60B00 - Tank Stick Height Function Enable Request Source: Monitor System Configuration Requests - Line: 53 _________________________ I60B00 MAY 16, 2018 4:06 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED ============================ Request: 54 - I60C00 - Tank Stick Height offset Request Source: Monitor System Configuration Requests - Line: 54 _________________________ I60C00 MAY 16, 2018 4:06 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 Unleaded 0.00 2 Unleaded 0.00 3 Premium 0.00 4 Additive 0.00 ============================ Request: 55 - I61200 - Tank Siphon Manifold partners Request Source: Monitor System Configuration Requests - Line: 55 _________________________ I61200 MAY 16, 2018 4:06 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 Unleaded NONE NONE 2 Unleaded NONE NONE 3 Premium NONE NONE 4 Additive NONE NONE ============================ Request: 56 - I63600 - Tank Periodic Leak Test Minimum Volume Request Source: Monitor System Configuration Requests - Line: 56 _________________________ I63600 MAY 16, 2018 4:06 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 Unleaded 24034 2 Unleaded 24034 3 Premium 24066 4 Additive 0 ============================ Request: 57 - I62A00 - Tank Annual Leak Test Minimum Volume Request Source: Monitor System Configuration Requests - Line: 57 _________________________ I62A00 MAY 16, 2018 4:06 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 Unleaded 24034 2 Unleaded 24034 3 Premium 24066 4 Additive 0 ============================ Request: 58 - I62C00 - Tank Periodic Test Type Request Source: Monitor System Configuration Requests - Line: 58 _________________________ I62C00 MAY 16, 2018 4:06 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 Unleaded STANDARD 2 Unleaded STANDARD 3 Premium STANDARD 4 Additive STANDARD ============================ Request: 59 - I62D00 - Enable-Disable Tank Test Leak Fail Alarms Request Source: Monitor System Configuration Requests - Line: 59 _________________________ I62D00 MAY 16, 2018 4:07 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 Unleaded GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 Unleaded GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 Premium GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 Additive GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ============================ Request: 60 - I63100 - Tank Leak Test Averaging Request Source: Monitor System Configuration Requests - Line: 60 _________________________ I63100 MAY 16, 2018 4:07 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 Unleaded OFF OFF 2 Unleaded OFF OFF 3 Premium OFF OFF 4 Additive OFF OFF ============================ Request: 61 - I63000 - Tank Leak Test notify Request Source: Monitor System Configuration Requests - Line: 61 _________________________ I63000 MAY 16, 2018 4:07 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 Unleaded OFF 2 Unleaded OFF 3 Premium OFF 4 Additive OFF ============================ Request: 62 - I63200 - Tank Test Siphon Break Request Source: Monitor System Configuration Requests - Line: 62 _________________________ I63200 MAY 16, 2018 4:07 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 Unleaded OFF 2 Unleaded OFF 3 Premium OFF 4 Additive OFF ============================ Request: 63 - I61000 - Tank delivery Delay Request Source: Monitor System Configuration Requests - Line: 63 _________________________ I61000 MAY 16, 2018 4:07 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 Unleaded 1 2 Unleaded 1 3 Premium 1 4 Additive 1 ============================ Request: 64 - I63A00 - Tank low Level Threshold for Line Manifold Request Source: Monitor System Configuration Requests - Line: 64 _________________________ I63A00 MAY 16, 2018 4:07 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 Unleaded 10.00% 2 Unleaded 10.00% 3 Premium 10.00% 4 Additive 10.00% ============================ Request: 65 - I61100 - Tank Leak Test Type and Start Time Request Source: Monitor System Configuration Requests - Line: 65 _________________________ I61100 MAY 16, 2018 4:07 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JUN 7, 2013 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED ============================ Request: 66 - I61300 - CSLD Probability of Detection Request Source: Monitor System Configuration Requests - Line: 66 _________________________ I61300 MAY 16, 2018 4:07 PM CSLD PROBABLITY OF DETECTION ============================ Request: 67 - I61400 - CSLD Climate Factor Request Source: Monitor System Configuration Requests - Line: 67 _________________________ I61400 MAY 16, 2018 4:07 PM CSLD CLIMATE FACTOR ============================ Request: 68 - I61600 - Accuchart Update Scheduling Request Source: Monitor System Configuration Requests - Line: 68 _________________________ I61600 MAY 16, 2018 4:07 PM TANK PRODUCT LABEL CAL UPDATE 1 Unleaded NEVER 2 Unleaded NEVER 3 Premium NEVER 4 Additive NEVER ============================ Request: 69 - I61A00 - In-Tank Leak Test Early Stop Request Source: Monitor System Configuration Requests - Line: 69 _________________________ I61A00 MAY 16, 2018 4:07 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 Unleaded DISABLED 2 Unleaded DISABLED 3 Premium DISABLED 4 Additive DISABLED ============================ Request: 70 - I61B00 - In-Tank Static Gross Test Auto-Confirm Request Source: Monitor System Configuration Requests - Line: 70 _________________________ I61B00 MAY 16, 2018 4:07 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM ============================ Request: 71 - I61C00 - CSLD Report Only mode Request Source: Monitor System Configuration Requests - Line: 71 _________________________ I61C00 MAY 16, 2018 4:07 PM CSLD REPORT ONLY ============================ Request: 72 - I62B00 - Tank Last Annual Test Request Source: Monitor System Configuration Requests - Line: 72 _________________________ I62B00 MAY 16, 2018 4:07 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 Unleaded ??? 0, 0 2 Unleaded ??? 0, 0 3 Premium ??? 0, 0 4 Additive ??? 0, 0 ============================ Request: 73 - I63300 - Leak Test Report Type Request Source: Monitor System Configuration Requests - Line: 73 _________________________ I63300 MAY 16, 2018 4:07 PM LEAK TEST REPORT FORMAT: NORMAL ============================ Request: 74 - I63400 - Tank HRM Reconciliation Warning limit Request Source: Monitor System Configuration Requests - Line: 74 _________________________ I63400 MAY 16, 2018 4:07 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 0 2 Unleaded 0 3 Premium 0 4 Additive 0 ============================ Request: 75 - I63500 - Tank HEM Reconciliation Alarm Request Source: Monitor System Configuration Requests - Line: 75 _________________________ I63500 MAY 16, 2018 4:07 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 1 2 Unleaded 1 3 Premium 1 4 Additive 1 ============================ Request: 76 - I63900 - Tank Accuchart End Shape Type and Factor Request Source: Monitor System Configuration Requests - Line: 76 _________________________ I63900 MAY 16, 2018 4:07 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 Unleaded END FACTOR: OTHER END VALUE: 1.0 2 Unleaded END FACTOR: OTHER END VALUE: 1.0 3 Premium END FACTOR: OTHER END VALUE: 1.0 4 Additive END FACTOR: HEMISPHER ============================ Request: 77 - I78000 - PLLD Setup Request Source: Monitor System Configuration Requests - Line: 77 _________________________ I78000 MAY 16, 2018 4:07 PM PRESSURE LINE LEAK SETUP Q 1:UNLEADED 87A TYP:2.0/3.0IN FIBERGLASS 2.0IN DIA LEN: 310 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV 0.10 GPH TEST: AUTO SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:YES LOW PRESSURE : 5 PSI T 1:Unleaded DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 2:UNLEADED 87B TYP:2.0/3.0IN FIBERGLASS 2.0IN DIA LEN: 320 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV 0.10 GPH TEST: AUTO SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:YES LOW PRESSURE : 5 PSI T 2:Unleaded DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 3:PREMIUM TYP:2.0/3.0IN FIBERGLASS 2.0IN DIA LEN: 330 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV 0.10 GPH TEST: AUTO SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:YES LOW PRESSURE : 5 PSI T 3:Premium DISPENSE MODE: STANDARD SENSOR: NON-VENTED PRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO ============================ Request: 78 - I77700 - PLLD Primary Line Diameter Request Source: Monitor System Configuration Requests - Line: 78 _________________________ I77700 MAY 16, 2018 4:08 PM ============================ Request: 79 - I77800 - PLLD Secondary Line Diameter Request Source: Monitor System Configuration Requests - Line: 79 _________________________ I77800 MAY 16, 2018 4:08 PM ============================ Request: 80 - I78C00 - PLLD 0.20 GPH Test Schedule Request Source: Monitor System Configuration Requests - Line: 80 _________________________ I78C00 MAY 16, 2018 4:08 PM PRESSURE LINE LEAK 0.20 TEST SCHEDULE LINE 0.20 GPH TEST Q 1:UNLEADED 87A REPETITIV Q 2:UNLEADED 87B REPETITIV Q 3:PREMIUM REPETITIV ============================ Request: 81 - I78300 - PLLD 0.10 GPH Test Schedule Request Source: Monitor System Configuration Requests - Line: 81 _________________________ I78300 MAY 16, 2018 4:08 PM PRESSURE LINE LEAK 0.10 TEST SCHEDULE LINE 0.10 GPH TEST Q 1:UNLEADED 87A AUTO Q 2:UNLEADED 87B AUTO Q 3:PREMIUM AUTO ============================ Request: 82 - I78F00 - PLLD Dispense Threshold Request Source: Monitor System Configuration Requests - Line: 82 _________________________ I78F00 MAY 16, 2018 4:08 PM PRESSURE LINE LEAK DISPENSE THRESHOLD LINE LOW PRESSURE Q 1:UNLEADED 87A 5 PSI Q 2:UNLEADED 87B 5 PSI Q 3:PREMIUM 5 PSI ============================ Request: 83 - I78700 - PLLD Disable Alarm Assignments Request Source: Monitor System Configuration Requests - Line: 83 _________________________ I78700 MAY 16, 2018 4:08 PM PRESSURE LLD SETUP REPORT Q 1:UNLEADED 87A IN-TANK ALARMS T 1:HIGH WATER ALARM T 2:HIGH WATER ALARM T 1:LOW PRODUCT ALARM T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L17:FUEL ALARM L18:FUEL ALARM L19:FUEL ALARM L21:FUEL ALARM L23:FUEL ALARM L 1:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L17:SENSOR OUT ALARM L18:SENSOR OUT ALARM L19:SENSOR OUT ALARM L21:SENSOR OUT ALARM L23:SENSOR OUT ALARM L 1:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM L17:SHORT ALARM L18:SHORT ALARM L19:SHORT ALARM L21:SHORT ALARM L23:SHORT ALARM L 1:HIGH LIQUID ALARM L 9:HIGH LIQUID ALARM L10:HIGH LIQUID ALARM L11:HIGH LIQUID ALARM L12:HIGH LIQUID ALARM L13:HIGH LIQUID ALARM L14:HIGH LIQUID ALARM L15:HIGH LIQUID ALARM L16:HIGH LIQUID ALARM L17:HIGH LIQUID ALARM L18:HIGH LIQUID ALARM L19:HIGH LIQUID ALARM L21:HIGH LIQUID ALARM L23:HIGH LIQUID ALARM L 1:LOW LIQUID ALARM L 9:LOW LIQUID ALARM L10:LOW LIQUID ALARM L11:LOW LIQUID ALARM L12:LOW LIQUID ALARM L13:LOW LIQUID ALARM L14:LOW LIQUID ALARM L15:LOW LIQUID ALARM L16:LOW LIQUID ALARM L17:LOW LIQUID ALARM L18:LOW LIQUID ALARM L19:LOW LIQUID ALARM L21:LOW LIQUID ALARM L23:LOW LIQUID ALARM L 1:LIQUID WARNING L 9:LIQUID WARNING L10:LIQUID WARNING L11:LIQUID WARNING L12:LIQUID WARNING L13:LIQUID WARNING L14:LIQUID WARNING L15:LIQUID WARNING L16:LIQUID WARNING L17:LIQUID WARNING L18:LIQUID WARNING L19:LIQUID WARNING L21:LIQUID WARNING L23:LIQUID WARNING PRESSURE LINE LEAK ALL:PLLD OPEN ALARM ALL:CONT HANDLE ALM ALL:LN EQUIP FAULT ALM SMARTSENSOR ALARMS s 1:SETUP DATA WARNING s 2:SETUP DATA WARNING s 3:SETUP DATA WARNING s11:SETUP DATA WARNING s13:SETUP DATA WARNING s 1:COMMUNICATION ALARM s 2:COMMUNICATION ALARM s 3:COMMUNICATION ALARM s11:COMMUNICATION ALARM s13:COMMUNICATION ALARM s 1:SENSOR FAULT ALARM s 2:SENSOR FAULT ALARM s 3:SENSOR FAULT ALARM s11:SENSOR FAULT ALARM s13:SENSOR FAULT ALARM s11:FUEL WARNING s13:FUEL WARNING s11:FUEL ALARM s13:FUEL ALARM s11:WATER WARNING s13:WATER WARNING s11:WATER ALARM s13:WATER ALARM s 1:HIGH LIQUID WARNING s 2:HIGH LIQUID WARNING s 3:HIGH LIQUID WARNING s11:HIGH LIQUID WARNING s13:HIGH LIQUID WARNING s 1:HIGH LIQUID ALARM s 2:HIGH LIQUID ALARM s 3:HIGH LIQUID ALARM s11:HIGH LIQUID ALARM s13:HIGH LIQUID ALARM s11:LOW LIQUID WARNING s13:LOW LIQUID WARNING s11:LOW LIQUID ALARM s13:LOW LIQUID ALARM s11:INSTALL ALARM s13:INSTALL ALARM s 1:SENSOR FAULT WARN s 2:SENSOR FAULT WARN s 3:SENSOR FAULT WARN s11:SENSOR FAULT WARN s13:SENSOR FAULT WARN s 1:VACUUM WARNING s 2:VACUUM WARNING s 3:VACUUM WARNING s 1:NO VACUUM ALARM s 2:NO VACUUM ALARM s 3:NO VACUUM ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL PC-ISD FAILURE Q 2:UNLEADED 87B IN-TANK ALARMS T 1:HIGH WATER ALARM T 2:HIGH WATER ALARM T 1:LOW PRODUCT ALARM T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 2:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L17:FUEL ALARM L19:FUEL ALARM L21:FUEL ALARM L 2:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L17:SENSOR OUT ALARM L19:SENSOR OUT ALARM L21:SENSOR OUT ALARM L 2:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM L17:SHORT ALARM L19:SHORT ALARM L21:SHORT ALARM L 2:HIGH LIQUID ALARM L 9:HIGH LIQUID ALARM L10:HIGH LIQUID ALARM L11:HIGH LIQUID ALARM L12:HIGH LIQUID ALARM L13:HIGH LIQUID ALARM L14:HIGH LIQUID ALARM L15:HIGH LIQUID ALARM L16:HIGH LIQUID ALARM L17:HIGH LIQUID ALARM L19:HIGH LIQUID ALARM L21:HIGH LIQUID ALARM L 2:LOW LIQUID ALARM L 9:LOW LIQUID ALARM L10:LOW LIQUID ALARM L11:LOW LIQUID ALARM L12:LOW LIQUID ALARM L13:LOW LIQUID ALARM L14:LOW LIQUID ALARM L15:LOW LIQUID ALARM L16:LOW LIQUID ALARM L17:LOW LIQUID ALARM L19:LOW LIQUID ALARM L21:LOW LIQUID ALARM L 2:LIQUID WARNING L 9:LIQUID WARNING L10:LIQUID WARNING L11:LIQUID WARNING L12:LIQUID WARNING L13:LIQUID WARNING L14:LIQUID WARNING L15:LIQUID WARNING L16:LIQUID WARNING L17:LIQUID WARNING L19:LIQUID WARNING L21:LIQUID WARNING PRESSURE LINE LEAK ALL:PLLD OPEN ALARM ALL:CONT HANDLE ALM ALL:LN EQUIP FAULT ALM SMARTSENSOR ALARMS s 4:SETUP DATA WARNING s 5:SETUP DATA WARNING s 6:SETUP DATA WARNING s11:SETUP DATA WARNING s13:SETUP DATA WARNING s 4:COMMUNICATION ALARM s 5:COMMUNICATION ALARM s 6:COMMUNICATION ALARM s11:COMMUNICATION ALARM s13:COMMUNICATION ALARM s 4:SENSOR FAULT ALARM s 5:SENSOR FAULT ALARM s 6:SENSOR FAULT ALARM s11:SENSOR FAULT ALARM s13:SENSOR FAULT ALARM s11:FUEL WARNING s13:FUEL WARNING s11:FUEL ALARM s13:FUEL ALARM s11:WATER WARNING s13:WATER WARNING s11:WATER ALARM s13:WATER ALARM s 4:HIGH LIQUID WARNING s 5:HIGH LIQUID WARNING s 6:HIGH LIQUID WARNING s11:HIGH LIQUID WARNING s13:HIGH LIQUID WARNING s 4:HIGH LIQUID ALARM s 5:HIGH LIQUID ALARM s 6:HIGH LIQUID ALARM s11:HIGH LIQUID ALARM s13:HIGH LIQUID ALARM s11:LOW LIQUID ALARM s13:LOW LIQUID ALARM s11:INSTALL ALARM s13:INSTALL ALARM s 4:SENSOR FAULT WARN s 5:SENSOR FAULT WARN s 6:SENSOR FAULT WARN s11:SENSOR FAULT WARN s13:SENSOR FAULT WARN s 4:VACUUM WARNING s 5:VACUUM WARNING s 6:VACUUM WARNING s13:VACUUM WARNING s 4:NO VACUUM ALARM s 5:NO VACUUM ALARM s 6:NO VACUUM ALARM s13:NO VACUUM ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL PC-ISD FAILURE Q 3:PREMIUM IN-TANK ALARMS T 3:HIGH WATER ALARM T 3:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 3:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L22:FUEL ALARM L23:FUEL ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L22:SENSOR OUT ALARM L23:SENSOR OUT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM L22:SHORT ALARM L23:SHORT ALARM L 3:HIGH LIQUID ALARM L 9:HIGH LIQUID ALARM L10:HIGH LIQUID ALARM L11:HIGH LIQUID ALARM L12:HIGH LIQUID ALARM L13:HIGH LIQUID ALARM L14:HIGH LIQUID ALARM L15:HIGH LIQUID ALARM L16:HIGH LIQUID ALARM L22:HIGH LIQUID ALARM L23:HIGH LIQUID ALARM L 3:LOW LIQUID ALARM L 9:LOW LIQUID ALARM L10:LOW LIQUID ALARM L11:LOW LIQUID ALARM L12:LOW LIQUID ALARM L13:LOW LIQUID ALARM L14:LOW LIQUID ALARM L15:LOW LIQUID ALARM L16:LOW LIQUID ALARM L22:LOW LIQUID ALARM L23:LOW LIQUID ALARM L 3:LIQUID WARNING L 9:LIQUID WARNING L10:LIQUID WARNING L11:LIQUID WARNING L12:LIQUID WARNING L13:LIQUID WARNING L14:LIQUID WARNING L15:LIQUID WARNING L16:LIQUID WARNING L22:LIQUID WARNING L23:LIQUID WARNING PRESSURE LINE LEAK ALL:PLLD OPEN ALARM ALL:CONT HANDLE ALM ALL:LN EQUIP FAULT ALM SMARTSENSOR ALARMS s 9:SETUP DATA WARNING s10:SETUP DATA WARNING s15:SETUP DATA WARNING s 9:COMMUNICATION ALARM s10:COMMUNICATION ALARM s15:COMMUNICATION ALARM s 9:SENSOR FAULT ALARM s10:SENSOR FAULT ALARM s15:SENSOR FAULT ALARM s15:FUEL WARNING s15:FUEL ALARM s15:WATER WARNING s15:WATER ALARM s 9:HIGH LIQUID WARNING s10:HIGH LIQUID WARNING s15:HIGH LIQUID WARNING s 9:HIGH LIQUID ALARM s10:HIGH LIQUID ALARM s15:HIGH LIQUID ALARM s15:LOW LIQUID ALARM s15:INSTALL ALARM s 9:SENSOR FAULT WARN s10:SENSOR FAULT WARN s15:SENSOR FAULT WARN s 9:VACUUM WARNING s10:VACUUM WARNING s 9:NO VACUUM ALARM s10:NO VACUUM ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL PC-ISD FAILURE ============================ Request: 84 - I70200 - Liquid Sensor Location Label Request Source: Monitor System Configuration Requests - Line: 84 _________________________ I70200 MAY 16, 2018 4:10 PM LIQUID LABEL DEVICE LABEL 1 UNLEADED 87A ANNULAR 2 UNLEADED 87B ANNULAR 3 PREMIUM ANNULAR 4 ADDITIVE ANNULAR 5 ADDITIVE SUMP 6 ADDITIVE VENT BOX 7 8 9 DISP PAN 1-2 10 DISP PAN 3-4 11 DISP PAN 5-6 12 DISP PAN 7-8 13 DISP PAN 9-10 14 DISP PAN 11-12 15 DISP PAN 13-14 16 DISP PAN 15-16 17 UNL 87A STP BRINE 18 UNL 87A FILL 19 UNL 87B STP BRINE 20 21 UNL 87B FILL 22 91 STP BRINE 23 91 FILL 24 PERMEATOR ============================ Request: 85 - I70300 - Liquid Sensor Type Request Source: Monitor System Configuration Requests - Line: 85 _________________________ I70300 MAY 16, 2018 4:10 PM LIQUID TYPE SENSOR LOCATION TYPE 1 UNLEADED 87A ANNULAR DUAL POINT HYDROSTATIC 2 UNLEADED 87B ANNULAR DUAL POINT HYDROSTATIC 3 PREMIUM ANNULAR DUAL POINT HYDROSTATIC 4 ADDITIVE ANNULAR DUAL POINT HYDROSTATIC 5 ADDITIVE SUMP DW SUMP 2-1 6 ADDITIVE VENT BOX DW SUMP 2-1 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) 9 DISP PAN 1-2 DW SUMP 2-1 10 DISP PAN 3-4 DW SUMP 2-1 11 DISP PAN 5-6 DW SUMP 2-1 12 DISP PAN 7-8 DW SUMP 2-1 13 DISP PAN 9-10 DW SUMP 2-1 14 DISP PAN 11-12 DW SUMP 2-1 15 DISP PAN 13-14 DW SUMP 2-1 16 DISP PAN 15-16 DW SUMP 2-1 17 UNL 87A STP BRINE TRI-STATE (SINGLE FLOAT) 18 UNL 87A FILL DW SUMP 2-1 19 UNL 87B STP BRINE TRI-STATE (SINGLE FLOAT) 20 TRI-STATE (SINGLE FLOAT) 21 UNL 87B FILL DW SUMP 2-1 22 91 STP BRINE TRI-STATE (SINGLE FLOAT) 23 91 FILL DW SUMP 2-1 24 PERMEATOR NORMALLY CLOSED ============================ Request: 86 - I70400 - Liquid Sensor Category Request Source: Monitor System Configuration Requests - Line: 86 _________________________ I70400 MAY 16, 2018 4:10 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNLEADED 87A ANNULAR ANNULAR SPACE 2 UNLEADED 87B ANNULAR ANNULAR SPACE 3 PREMIUM ANNULAR ANNULAR SPACE 4 ADDITIVE ANNULAR ANNULAR SPACE 5 ADDITIVE SUMP STP SUMP 6 ADDITIVE VENT BOX DISPENSER PAN 7 OTHER SENSORS 8 OTHER SENSORS 9 DISP PAN 1-2 DISPENSER PAN 10 DISP PAN 3-4 DISPENSER PAN 11 DISP PAN 5-6 DISPENSER PAN 12 DISP PAN 7-8 DISPENSER PAN 13 DISP PAN 9-10 DISPENSER PAN 14 DISP PAN 11-12 DISPENSER PAN 15 DISP PAN 13-14 DISPENSER PAN 16 DISP PAN 15-16 DISPENSER PAN 17 UNL 87A STP BRINE ANNULAR SPACE 18 UNL 87A FILL OTHER SENSORS 19 UNL 87B STP BRINE ANNULAR SPACE 20 OTHER SENSORS 21 UNL 87B FILL OTHER SENSORS 22 91 STP BRINE ANNULAR SPACE 23 91 FILL ANNULAR SPACE 24 PERMEATOR OTHER SENSORS ============================ Request: 87 - I74200 - Type "A" 2 Wire Sensor Location Label Request Source: Monitor System Configuration Requests - Line: 87 _________________________ I74200 MAY 16, 2018 4:10 PM ============================ Request: 88 - I74300 - Type "A" 2 Wire Sensor Type Request Source: Monitor System Configuration Requests - Line: 88 _________________________ I74300 MAY 16, 2018 4:10 PM ============================ Request: 89 - I74400 - Type "A" 2 Wire Sensor Category Request Source: Monitor System Configuration Requests - Line: 89 _________________________ I74400 MAY 16, 2018 4:10 PM ============================ Request: 90 - I74700 - Type "B" 3 Wire Sensor Location Label Request Source: Monitor System Configuration Requests - Line: 90 _________________________ I74700 MAY 16, 2018 4:10 PM ============================ Request: 91 - I74800 - Type "B" 3 Wire Sensor Type Request Source: Monitor System Configuration Requests - Line: 91 _________________________ I74800 MAY 16, 2018 4:10 PM ============================ Request: 92 - I74900 - Type "B" Sensor Category Request Source: Monitor System Configuration Requests - Line: 92 _________________________ I74900 MAY 16, 2018 4:10 PM ============================ Request: 93 - I7BC00 - I/O Device Line Disable Assignments Request Source: Monitor System Configuration Requests - Line: 93 _________________________ I7BC00 MAY 16, 2018 4:10 PM ============================ Request: 94 - I80200 - I/O Input location Label Request Source: Monitor System Configuration Requests - Line: 94 _________________________ I80200 MAY 16, 2018 4:10 PM ============================ Request: 95 - I80300 - I/O Input Type Request Source: Monitor System Configuration Requests - Line: 95 _________________________ I80300 MAY 16, 2018 4:10 PM ============================ Request: 96 - I80400 - I/O Input Dispense mode Request Source: Monitor System Configuration Requests - Line: 96 _________________________ I80400 MAY 16, 2018 4:10 PM ============================ Request: 97 - I80700 - I/O Relay location label Request Source: Monitor System Configuration Requests - Line: 97 _________________________ I80700 MAY 16, 2018 4:10 PM RELAY LABEL DEVICE LABEL 1 DATA HUT V-R ALARM 2 WAREHOUSE V-R ALARM 3 ADDITIVE SHUTDOWN 4 ============================ Request: 98 - I80900 - I/O Relay Orientation Request Source: Monitor System Configuration Requests - Line: 98 _________________________ I80900 MAY 16, 2018 4:11 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 DATA HUT V-R ALARM NORMALLY OPEN 2 WAREHOUSE V-R ALARM NORMALLY OPEN 3 ADDITIVE SHUTDOWN NORMALLY OPEN 4 NORMALLY OPEN ============================ Request: 99 - I80B00 - I/O Relay Tank Assignment Request Source: Monitor System Configuration Requests - Line: 99 _________________________ I80B00 MAY 16, 2018 4:11 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 DATA HUT V-R ALARM NONE 2 WAREHOUSE V-R ALARM NONE 3 ADDITIVE SHUTDOWN 4 4 NONE ============================ Request: 100 - I80A00 - I/O Relay Type Request Source: Monitor System Configuration Requests - Line: 100 _________________________ I80A00 MAY 16, 2018 4:11 PM RELAY TYPE RELAY DESIGNATION TYPE 1 DATA HUT V-R ALARM STANDARD 2 WAREHOUSE V-R ALARM STANDARD 3 ADDITIVE SHUTDOWN PUMP CONTROL OUTPUT 4 STANDARD ============================ Request: 101 - I80C00 - I/O External input Type Request Source: Monitor System Configuration Requests - Line: 101 _________________________ I80C00 MAY 16, 2018 4:11 PM ============================ Request: 102 - I80800 - I/O Relay Alarm Assignments Request Source: Monitor System Configuration Requests - Line: 102 _________________________ I80800 MAY 16, 2018 4:11 PM RELAY SETUP REPORT R 1:DATA HUT V-R ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:HIGH WATER ALARM ALL:OVERFILL ALARM ALL:LOW PRODUCT ALARM ALL:SUDDEN LOSS ALARM ALL:HIGH PRODUCT ALARM ALL:INVALID FUEL LEVEL ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED ALL:MAX PRODUCT ALARM ALL:LOW TEMP WARNING ALL:FUEL QUALITY ALARM LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM ALL:HIGH LIQUID ALARM ALL:LOW LIQUID ALARM ALL:LIQUID WARNING PRESSURE LINE LEAK ALL:GROSS LINE FAIL ALL:ANNUAL LINE FAIL ALL:PER TST NEEDED WRN ALL:PER TST NEEDED ALM ALL:PLLD OPEN ALARM ALL:PLLD SHUTDOWN ALARM ALL:PERIODIC LINE FAIL ALL:ANN TST NEEDED WRN ALL:ANN TST NEEDED ALM ALL:LOW PRESSURE ALARM ALL:CONT HANDLE ALM ALL:FUEL OUT ALL:LN EQUIP FAULT ALM ALL:GRS TST NEEDED ALM SMARTSENSOR ALARMS ALL:SETUP DATA WARNING ALL:COMMUNICATION ALARM ALL:SENSOR FAULT ALARM ALL:FUEL WARNING ALL:FUEL ALARM ALL:WATER WARNING ALL:WATER ALARM ALL:HIGH LIQUID WARNING ALL:HIGH LIQUID ALARM ALL:LOW LIQUID WARNING ALL:LOW LIQUID ALARM ALL:TEMPERATURE WARNING ALL:RELAY ACTIVE ALL:INSTALL ALARM ALL:SENSOR FAULT WARN ALL:VACUUM WARNING ALL:NO VACUUM ALARM ALL:BATTERY WARNING ISD SITE ALARMS ISD STAGE I WARN ISD GROSS PRES WARN ISD GROSS PRES FAIL ISD DEGRD PRES WARN ISD DEGRD PRES FAIL ISD VAPOR LEAK WARN ISD VAPOR LEAK FAIL ISD VP PRES WARN ISD VP PRES FAIL ISD VP STATUS WARN ISD VP STATUS FAIL MISSING RELAY SETUP MISSING HOSE SETUP MISSING TANK SETUP MISS VAPOR FLOW MTR MISS VAPOR PRES SEN MISSING VP INPUT ISD SETUP WARN ISD SETUP FAIL ISD SENSOR OUT WARN ISD SENSOR OUT FAIL PC-ISD FAILURE PMC ALARMS VP RUNTIME FAULT VP EMISSIONS WARN VP EMISSIONS FAIL VP PRESSURE WARN VP PRESSURE FAIL VP DUTY CYCLE WARN VP DUTY CYCLE FAIL PMC SETUP FAIL PMC SENSOR FAULT R 2:WAREHOUSE V-R ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:HIGH WATER ALARM ALL:OVERFILL ALARM ALL:LOW PRODUCT ALARM ALL:SUDDEN LOSS ALARM ALL:HIGH PRODUCT ALARM ALL:INVALID FUEL LEVEL ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED ALL:MAX PRODUCT ALARM ALL:LOW TEMP WARNING ALL:FUEL QUALITY ALARM LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM ALL:HIGH LIQUID ALARM ALL:LOW LIQUID ALARM ALL:LIQUID WARNING PRESSURE LINE LEAK ALL:GROSS LINE FAIL ALL:ANNUAL LINE FAIL ALL:PER TST NEEDED WRN ALL:PER TST NEEDED ALM ALL:PLLD OPEN ALARM ALL:PLLD SHUTDOWN ALARM ALL:PERIODIC LINE FAIL ALL:ANN TST NEEDED WRN ALL:ANN TST NEEDED ALM ALL:LOW PRESSURE ALARM ALL:CONT HANDLE ALM ALL:FUEL OUT ALL:LN EQUIP FAULT ALM ALL:GRS TST NEEDED ALM SMARTSENSOR ALARMS ALL:SETUP DATA WARNING ALL:COMMUNICATION ALARM ALL:SENSOR FAULT ALARM ALL:FUEL WARNING ALL:FUEL ALARM ALL:WATER WARNING ALL:WATER ALARM ALL:HIGH LIQUID WARNING ALL:HIGH LIQUID ALARM ALL:LOW LIQUID WARNING ALL:LOW LIQUID ALARM ALL:TEMPERATURE WARNING ALL:RELAY ACTIVE ALL:INSTALL ALARM ALL:SENSOR FAULT WARN ALL:VACUUM WARNING ALL:NO VACUUM ALARM ALL:BATTERY WARNING ISD SITE ALARMS ISD STAGE I WARN ISD GROSS PRES WARN ISD GROSS PRES FAIL ISD DEGRD PRES WARN ISD DEGRD PRES FAIL ISD VAPOR LEAK WARN ISD VAPOR LEAK FAIL ISD VP PRES WARN ISD VP PRES FAIL ISD VP STATUS WARN ISD VP STATUS FAIL MISSING RELAY SETUP MISSING HOSE SETUP MISSING TANK SETUP MISS VAPOR FLOW MTR MISS VAPOR PRES SEN MISSING VP INPUT ISD SETUP WARN ISD SETUP FAIL ISD SENSOR OUT WARN ISD SENSOR OUT FAIL PC-ISD FAILURE PMC ALARMS VP RUNTIME FAULT VP EMISSIONS WARN VP EMISSIONS FAIL VP PRESSURE WARN VP PRESSURE FAIL VP DUTY CYCLE WARN VP DUTY CYCLE FAIL PMC SETUP FAIL PMC SENSOR FAULT R 3:ADDITIVE SHUTDOWN TYPE: PUMP CONTROL OUTPUT TANK #: 4 IN-TANK ALARMS T 4:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 4:HIGH LIQUID ALARM L 5:HIGH LIQUID ALARM L 6:HIGH LIQUID ALARM L 4:LOW LIQUID ALARM L 5:LOW LIQUID ALARM L 6:LOW LIQUID ALARM L 4:LIQUID WARNING L 5:LIQUID WARNING L 6:LIQUID WARNING SMARTSENSOR ALARMS s12:COMMUNICATION ALARM s14:COMMUNICATION ALARM s12:SENSOR FAULT ALARM s14:SENSOR FAULT ALARM s12:HIGH LIQUID WARNING s14:HIGH LIQUID WARNING s12:HIGH LIQUID ALARM s14:HIGH LIQUID ALARM s12:SENSOR FAULT WARN s14:SENSOR FAULT WARN s12:VACUUM WARNING s14:VACUUM WARNING s12:NO VACUUM ALARM s14:NO VACUUM ALARM R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - ============================ Request: 103 - I79000 - DIM Software Revision Request Source: Monitor System Configuration Requests - Line: 103 _________________________ I79000 MAY 16, 2018 4:12 PM EDIM:1 VR:330273-002-C TD:97.11.13.15.52 ============================ Request: 104 - I79100 - Mechanical Dispenser Interface String Request Source: Monitor System Configuration Requests - Line: 104 _________________________ I79100 MAY 16, 2018 4:12 PM ============================ Request: 105 - I72300 - Smart Sensor Category Request Source: Monitor System Configuration Requests - Line: 105 _________________________ I72300 MAY 16, 2018 4:12 PM 279395 COSTCO 643 4900 PANAMA LANE BAKERSFIELD, CA SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 UNL 87A PRODUCT LINE VAC SENSOR 02 VAPOR LINE VAC SENSOR 03 UNL 87A VENT LINE VAC SENSOR 04 UNL 87B PRODUCT LINE VAC SENSOR 05 UNL 87B SIPHON LINE VAC SENSOR 06 UNL 87B VENT LINE VAC SENSOR 07 PRESSURE SENSOR 3-4 VAPOR PRESSURE 08 ATP ATM P SENSOR 09 PREMIUM PRODUCT LINE VAC SENSOR 10 PREMIUM VENT LINE VAC SENSOR 11 87A STP SUMP MAG SENSOR 12 ADDITIVE PRODUCT VAC VAC SENSOR 13 87B STP SUMP MAG SENSOR 14 ADDITIVE VENT VAC VAC SENSOR 15 PREMIUM STP SUMP MAG SENSOR 16 UNKNOWN 17 DISP 1-2 AIR FLOW METER 18 DISP 3-4 AIR FLOW METER 19 DISP 5-6 AIR FLOW METER 20 DISP 7-8 AIR FLOW METER 21 DISP 9-10 AIR FLOW METER 22 DISP 11-12 AIR FLOW METER 23 DISP 13-14 AIR FLOW METER 24 DISP 15-16 AIR FLOW METER 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN ============================ Request: 106 - IV4E00 - ISD EVR Type Request Source: Monitor System Configuration Requests - Line: 106 _________________________ IV4E00 MAY 16, 2018 4:13 PM 279395 COSTCO 643 4900 PANAMA LANE BAKERSFIELD, CA EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC ============================ Request: 107 - IV4F00 - ISD Nozzle Type Request Source: Monitor System Configuration Requests - Line: 107 _________________________ IV4F00 MAY 16, 2018 4:13 PM 279395 COSTCO 643 4900 PANAMA LANE BAKERSFIELD, CA NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 ============================ Request: 108 - IV4000 - Vapor Processor Type Request Source: Monitor System Configuration Requests - Line: 108 _________________________ IV4000 MAY 16, 2018 4:13 PM 279395 COSTCO 643 4900 PANAMA LANE BAKERSFIELD, CA VAPOR PROCESSOR TYPE NONE ============================ Request: 109 - IV4700 - ISD Assessment Start and Post Delay Request Source: Monitor System Configuration Requests - Line: 109 _________________________ IV4700 MAY 16, 2018 4:13 PM 279395 COSTCO 643 4900 PANAMA LANE BAKERSFIELD, CA ASSESSMENT TIME START TIME: 11:59 PM TIME DELAY MINUTES: 1 ============================ Request: 110 - IV5200 - High ORVR Configuration Request Source: Monitor System Configuration Requests - Line: 110 _________________________ IV5200 MAY 16, 2018 4:13 PM 279395 COSTCO 643 4900 PANAMA LANE BAKERSFIELD, CA ACCEPT HIGH ORVR: NO ============================ Request: 111 - IV4A00 - ISD Hose Table Request Source: Monitor System Configuration Requests - Line: 111 _________________________ IV4A00 MAY 16, 2018 4:13 PM 279395 COSTCO 643 4900 PANAMA LANE BAKERSFIELD, CA ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 UU BLEND2 02 02 02 01 UU BLEND2 03 03 03 02 UU BLEND2 04 04 04 02 UU BLEND2 05 05 05 03 UU BLEND2 06 06 06 03 UU BLEND2 07 07 07 04 UU BLEND2 08 08 08 04 UU BLEND2 09 09 09 05 UU BLEND2 10 10 10 05 UU BLEND2 11 11 11 06 UU BLEND2 12 12 12 06 UU BLEND2 13 13 13 07 UU BLEND2 14 14 14 07 UU BLEND2 15 15 15 08 UU BLEND2 16 16 16 08 UU BLEND2 ============================ Request: 112 - IV4B00 - ISD Grade Table Request Source: Monitor System Configuration Requests - Line: 112 _________________________ IV4B00 MAY 16, 2018 4:13 PM 279395 COSTCO 643 4900 PANAMA LANE BAKERSFIELD, CA PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 01/01 02/01 xx/xx xx/xx 02 01 01/02 02/02 xx/xx xx/xx 03 02 01/03 02/03 xx/xx xx/xx 04 02 01/04 02/04 xx/xx xx/xx 05 03 01/05 02/05 xx/xx xx/xx 06 03 01/06 02/06 xx/xx xx/xx 07 04 01/07 02/07 xx/xx xx/xx 08 04 01/08 02/08 xx/xx xx/xx 09 05 01/09 02/09 xx/xx xx/xx 10 05 01/10 02/10 xx/xx xx/xx 11 06 01/11 02/11 xx/xx xx/xx 12 06 01/12 02/12 xx/xx xx/xx 13 07 01/13 02/13 xx/xx xx/xx 14 07 01/14 02/14 xx/xx xx/xx 15 08 01/15 02/15 xx/xx xx/xx 16 08 01/16 02/16 xx/xx xx/xx ============================ Request: 113 - IV4900 - ISD Hose Label Table Request Source: Monitor System Configuration Requests - Line: 113 _________________________ IV4900 MAY 16, 2018 4:13 PM 279395 COSTCO 643 4900 PANAMA LANE BAKERSFIELD, CA LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 ============================ Request: 114 - IV1000 - ISD Version Request Source: Monitor System Configuration Requests - Line: 114 _________________________ IV1000 MAY 16, 2018 4:13 PM ISD VERSION: 01.05 End of Report: 180516 +============================================================================ | Monitoring System Report Saved at: Wednesday, May 16, 2018 - 4:12:10 PM | (Report Saved Date/Time from PC Clock) | Using Monitoring System Report Utility | | Version: Version 6.0.0.100 | +============================================================================