HomeMy WebLinkAbout#643 Bakersfield VR Alarm History 5-16-18file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] +=============================================================+| Monitoring System Report using Report Utility || Version: Version 6.0.0.100 |+=============================================================+ Connected on PC Port: COM4 Settings: 1200 Odd 7, 1 Connect Time/Date from PC Clock: Wednesday, May 16, 2018 - 4:02:15 PM Connect Date from Monitoring System: 180516Connect Time from Monitoring System Clock: 16:04 Site Label: 279395 COSTCO 6434900 PANAMA LANEBAKERSFIELD, CA ============================Request: 1 - 200 - Site LocationRequest Source: Monitor System Configuration Requests - Line: 1 _________________________ 200279395 COSTCO 6434900 PANAMA LANE BAKERSFIELD, CA MAY 16, 2018 4:04 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 Unleaded 21167 77.00 0.0 73.9 8876 2 Unleaded 21177 77.05 0.0 73.8 8866 3 Premium 19643 71.36 0.0 73.7 10440 4 Additive 758 23.64 77.0 756 ============================Request: 2 - I90500 - System Revision LevelRequest Source: Monitor System Configuration Requests - Line: 2 _________________________ I90500MAY 16, 2018 4:04 PMSOFTWARE REVISION LEVELVERSION 333.04SOFTWARE# 346333-100-E CREATED - 13.06.07.08.25 S-MODULE# 330160-164-aSYSTEM FEATURES: PERIODIC IN-TANK TESTS file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] ANNUAL IN-TANK TESTS BIR ISD/APMPLLD 0.10 AUTO 0.20 REPETITIVWPLLD 0.10 AUTO 0.20 REPETITIV ============================Request: 3 - I50500 - System Type & languageRequest Source: Monitor System Configuration Requests - Line: 3 _________________________ I50500MAY 16, 2018 4:04 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S.SYSTEM LANGUAGE ENGLISHSYSTEM DATE/TIME FORMATMON DD YYYY HH:MM:SS xM ============================Request: 4 - I50201 - Shift Start Time 1Request Source: Monitor System Configuration Requests - Line: 4 _________________________ I50201MAY 16, 2018 4:04 PM SHIFT TIME 1 : DISABLED ============================Request: 5 - I50202 - Shift Start Time 2Request Source: Monitor System Configuration Requests - Line: 5 _________________________ I50202MAY 16, 2018 4:04 PM SHIFT TIME 2 : DISABLED ============================Request: 6 - I50203 - Shift Start Time 3Request Source: Monitor System Configuration Requests - Line: 6 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] _________________________ I50203MAY 16, 2018 4:04 PM SHIFT TIME 3 : DISABLED ============================Request: 7 - I50204 - Shift Start Time 4Request Source: Monitor System Configuration Requests - Line: 7 _________________________ I50204MAY 16, 2018 4:04 PM SHIFT TIME 4 : DISABLED ============================Request: 8 - I54600 - Tank Periodic Test Needed WarningRequest Source: Monitor System Configuration Requests - Line: 8 _________________________ I54600MAY 16, 2018 4:04 PM TANK PER TST NEEDED WRN: DISABLED ============================Request: 9 - I54900 - Tank Annual Test Needed WarningRequest Source: Monitor System Configuration Requests - Line: 9 _________________________ I54900MAY 16, 2018 4:05 PM TANK ANN TST NEEDED WRN: DISABLED ============================Request: 10 - I55300 - Line Re-Enable MethodRequest Source: Monitor System Configuration Requests - Line: 10 _________________________ I55300MAY 16, 2018 4:05 PM LINE RE-ENABLE METHODPASS LINE TEST file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] ============================Request: 11 - I55600 - Line periodic Test Needed WarningRequest Source: Monitor System Configuration Requests - Line: 11 _________________________ I55600MAY 16, 2018 4:05 PM LINE PER TST NEEDED WRN: DISABLED ============================Request: 12 - I55900 - Line Annual Test Needed WarningRequest Source: Monitor System Configuration Requests - Line: 12 _________________________ I55900MAY 16, 2018 4:05 PM LINE ANN TST NEEDED WRN: DISABLED ============================Request: 13 - I50D00 - Print Temperature CompensationRequest Source: Monitor System Configuration Requests - Line: 13 _________________________ I50D00MAY 16, 2018 4:05 PM PRINT TC VOLUMESENABLED ============================Request: 14 - I50E00 - Temperature Compensation ValueRequest Source: Monitor System Configuration Requests - Line: 14 _________________________ I50E00MAY 16, 2018 4:05 PM TEMP COMPENSATIONVALUE (DEG F ): 60.0 ============================Request: 15 - I60B00 - Tank Stick Height Function EnableRequest Source: Monitor System Configuration Requests - Line: 15 _________________________ file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] I60B00MAY 16, 2018 4:05 PM STICK HEIGHT OFFSET ENABLE STATUSDISABLED ============================Request: 16 - I51400 - H-Protocol Height-Volume FormatRequest Source: Monitor System Configuration Requests - Line: 16 _________________________ I51400MAY 16, 2018 4:05 PM H-PROTOCOL DATA FORMATHEIGHT ============================Request: 17 - I51A01 - Auto Daylight Saving TimeRequest Source: Monitor System Configuration Requests - Line: 17 _________________________ I51A01MAY 16, 2018 4:05 PM DAYLIGHT SAVING TIMEDISABLED ============================Request: 18 - I51B00 - Start-End Daylight Saving TimeRequest Source: Monitor System Configuration Requests - Line: 18 _________________________ I51B00MAY 16, 2018 4:05 PM ============================Request: 19 - I51600 - Re-Direct Local PrintoutRequest Source: Monitor System Configuration Requests - Line: 19 _________________________ I51600MAY 16, 2018 4:05 PM RE-DIRECT LOCAL PRINTOUTDISABLED ============================ file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] Request: 20 - I50400 - RS-232 Security CodeRequest Source: Monitor System Configuration Requests - Line: 20 _________________________ I50400MAY 16, 2018 4:05 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED ============================Request: 21 - I21900 - Tank Chart SecurityRequest Source: Monitor System Configuration Requests - Line: 21 _________________________ I21900MAY 16, 2018 4:05 PM TANK CHART SECURITYDISABLED ============================Request: 22 - I5BD00 - Custom AlarmsRequest Source: Monitor System Configuration Requests - Line: 22 _________________________ I5BD00MAY 16, 2018 4:05 PM CUSTOM ALARM LABELS DISABLED ============================Request: 23 - I56000 - Mass Density Enable-DisableRequest Source: Monitor System Configuration Requests - Line: 23 _________________________ I56000MAY 16, 2018 4:05 PM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] MASS/DENSITY DISABLED ============================Request: 24 - I88101 - Comm Port 1 SettingsRequest Source: Monitor System Configuration Requests - Line: 24 _________________________ I88101MAY 16, 2018 4:05 PMPORT SETTINGS: COMM BOARD : 1 (EDIM )RS-232 SECURITYCODE : ****** ============================Request: 25 - I88102 - Comm Port 2 SettingsRequest Source: Monitor System Configuration Requests - Line: 25 _________________________ I88102MAY 16, 2018 4:05 PMPORT SETTINGS: COMM BOARD : 2 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATARS-232 SECURITYCODE : ****** DTR NORMAL STATE: HIGH ============================Request: 26 - I88103 - Comm Port 3 SettingsRequest Source: Monitor System Configuration Requests - Line: 26 _________________________ I88103MAY 16, 2018 4:05 PMPORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 1200 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATARS-232 SECURITY file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] CODE : ****** ============================Request: 27 - I88104 - Comm Port 4 SettingsRequest Source: Monitor System Configuration Requests - Line: 27 _________________________ I88104MAY 16, 2018 4:05 PM ============================Request: 28 - I88105 - Comm Port 5 SettingsRequest Source: Monitor System Configuration Requests - Line: 28 _________________________ I88105MAY 16, 2018 4:05 PM ============================Request: 29 - I88106 - Comm Port 6 SettingsRequest Source: Monitor System Configuration Requests - Line: 29 _________________________ I88106MAY 16, 2018 4:05 PM ============================Request: 30 - I52000 - Receiver Auto Dial Type and Start TimeRequest Source: Monitor System Configuration Requests - Line: 30 _________________________ I52000MAY 16, 2018 4:05 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE MAY 16, 2018 DISABLED 2 ON DATE MAY 16, 2018 DISABLED 3 ON DATE MAY 16, 2018 DISABLED 4 ON DATE MAY 16, 2018 DISABLED 5 ON DATE MAY 16, 2018 DISABLED 6 ON DATE MAY 16, 2018 DISABLED 7 ON DATE MAY 16, 2018 DISABLED 8 VEEDER-ROOT FMS ON DATE MAY 16, 2018 DISABLED ============================Request: 31 - I60100 - Tank ConfigurationRequest Source: Monitor System Configuration Requests - Line: 31 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] _________________________ I60100MAY 16, 2018 4:05 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 Unleaded ON 2 Unleaded ON 3 Premium ON 4 Additive ON ============================Request: 32 - I60200 - Tank Product LabelRequest Source: Monitor System Configuration Requests - Line: 32 _________________________ I60200MAY 16, 2018 4:05 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 Unleaded 2 Unleaded 3 Premium 4 Additive ============================Request: 33 - I60300 - Tank Product CodeRequest Source: Monitor System Configuration Requests - Line: 33 _________________________ I60300MAY 16, 2018 4:05 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 Unleaded 1 2 Unleaded 1 3 Premium 2 4 Additive 3 ============================Request: 34 - I60900 - Tank Thermal Expansion Coefficient Request Source: Monitor System Configuration Requests - Line: 34 _________________________ I60900MAY 16, 2018 4:05 PM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 Unleaded 0.000700 2 Unleaded 0.000700 3 Premium 0.000700 4 Additive 0.000405 ============================Request: 35 - I60700 - Tank DiameterRequest Source: Monitor System Configuration Requests - Line: 35 _________________________ I60700MAY 16, 2018 4:05 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 Unleaded 118.25 2 Unleaded 118.25 3 Premium 118.16 4 Additive 47.50 ============================Request: 36 - I60A00 - Tank Full VolumeRequest Source: Monitor System Configuration Requests - Line: 36 _________________________ I60A00MAY 16, 2018 4:05 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 Unleaded 20 PTS 30043 2 Unleaded 20 PTS 30043 3 Premium 20 PTS 30083 4 Additive 4 PTS 1514 ============================Request: 37 - I60400 - Tank 1 Point Full Volume HeightRequest Source: Monitor System Configuration Requests - Line: 37 _________________________ I60400MAY 16, 2018 4:05 PM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 Unleaded 30043 2 Unleaded 30043 3 Premium 30083 4 Additive 1514 ============================Request: 38 - I60500 - Tank 4 Point Full, 3/4, 1/2. 1/4 VolumesRequest Source: Monitor System Configuration Requests - Line: 38 _________________________ I60500MAY 16, 2018 4:05 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 Unleaded 30043 24619 15381 6034 2 Unleaded 30043 24614 15374 6028 3 Premium 30083 24833 15630 6251 4 Additive 1514 1220 762 299 ============================Request: 39 - I60600 - Tank 20 Point Full, 95%, 90%, ...volumesRequest Source: Monitor System Configuration Requests - Line: 39 _________________________ I60600MAY 16, 2018 4:05 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 Unleaded 30043 29660 28767 27584 26185 24619 22922 21124 19252 17330 15381 13428 11493 9600 7771 6034 4416 2951 1681 669 2 Unleaded 30043 29658 28764 27580 26181 24614 22917 21118 19246 17323 15374 13421 11487 9594 7766 6028 4411 2946 1678 667 3 Premium 30083 29778 28922 27764 26384 24833 23148 21360 19494 17577 15630 13677 11740 9840 8002 6251 4615 3127 1829 777 4 Additive 1514 0 0 0 0 1220 0 0 0 0 762 0 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] 0 0 0 299 0 0 0 0 ============================Request: 40 - I61500 - BIR Meter Data PresentRequest Source: Monitor System Configuration Requests - Line: 40 _________________________ I61500MAY 16, 2018 4:06 PM TANK PRODUCT LABEL METER DATA 1 Unleaded YES 2 Unleaded YES 3 Premium YES 4 Additive YES ============================Request: 41 - I62F00 - Mag Probe Float SizeRequest Source: Monitor System Configuration Requests - Line: 41 _________________________ I62F00MAY 16, 2018 4:06 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 Unleaded 4.0 IN. 2 Unleaded 4.0 IN. 3 Premium 4.0 IN. 4 Additive 4.0 IN. ============================Request: 42 - I62700 - Tank Height Water warning limitRequest Source: Monitor System Configuration Requests - Line: 42 _________________________ I62700MAY 16, 2018 4:06 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 Unleaded 1.0 2 Unleaded 1.0 3 Premium 1.0 ============================Request: 43 - I64200 - Tank Water Filter LimitRequest Source: Monitor System Configuration Requests - Line: 43 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] _________________________ I64200MAY 16, 2018 4:06 PM WATER ALARM FILTER TANK PRODUCT LABEL 1 Unleaded LOW 2 Unleaded LOW 3 Premium LOW ============================Request: 44 - I62400 - Tank High Water Level LimitRequest Source: Monitor System Configuration Requests - Line: 44 _________________________ I62400MAY 16, 2018 4:06 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 Unleaded 1.5 2 Unleaded 1.5 3 Premium 1.5 ============================Request: 45 - I62800 - Tank Maximum Volume LimitRequest Source: Monitor System Configuration Requests - Line: 45 _________________________ I62800MAY 16, 2018 4:06 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 30043 2 Unleaded 30043 3 Premium 30083 4 Additive 1514 ============================Request: 46 - I62300 - Tank Overfill Level limitRequest Source: Monitor System Configuration Requests - Line: 46 _________________________ I62300MAY 16, 2018 4:06 PM TANK OVERFILL LEVEL LIMIT file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] TANK PRODUCT LABEL GALLONS 1 Unleaded 27039 2 Unleaded 27039 3 Premium 27075 4 Additive 1363 ============================Request: 47 - I62200 - Tank High Level LimitRequest Source: Monitor System Configuration Requests - Line: 47 _________________________ I62200MAY 16, 2018 4:06 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 28541 2 Unleaded 28541 3 Premium 28579 4 Additive 1438 ============================Request: 48 - I62900 - Tank Delivery Required limitRequest Source: Monitor System Configuration Requests - Line: 48 _________________________ I62900MAY 16, 2018 4:06 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 4506 2 Unleaded 4506 3 Premium 4512 4 Additive 150 ============================Request: 49 - I62100 - Tank Low Level LimitRequest Source: Monitor System Configuration Requests - Line: 49 _________________________ I62100MAY 16, 2018 4:06 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 800 2 Unleaded 800 3 Premium 800 4 Additive 114 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] ============================Request: 50 - I62600 - Tank Leak Alarm LimitRequest Source: Monitor System Configuration Requests - Line: 50 _________________________ I62600MAY 16, 2018 4:06 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 8 2 Unleaded 8 3 Premium 8 4 Additive 99 ============================Request: 51 - I62500 - Tank Sudden Loss LimitRequest Source: Monitor System Configuration Requests - Line: 51 _________________________ I62500MAY 16, 2018 4:06 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 25 2 Unleaded 25 3 Premium 25 4 Additive 99 ============================Request: 52 - I60800 - Tank TiltRequest Source: Monitor System Configuration Requests - Line: 52 _________________________ I60800MAY 16, 2018 4:06 PM TANK TILT TANK PRODUCT LABEL INCHES 1 Unleaded 0.00 2 Unleaded 0.00 3 Premium 0.00 4 Additive 0.00 ============================Request: 53 - I60B00 - Tank Stick Height Function EnableRequest Source: Monitor System Configuration Requests - Line: 53 _________________________ file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] I60B00MAY 16, 2018 4:06 PM STICK HEIGHT OFFSET ENABLE STATUSDISABLED ============================Request: 54 - I60C00 - Tank Stick Height offsetRequest Source: Monitor System Configuration Requests - Line: 54 _________________________ I60C00MAY 16, 2018 4:06 PM TANK STICK HEIGHT OFFSETTANK PRODUCT LABEL INCHES 1 Unleaded 0.00 2 Unleaded 0.00 3 Premium 0.00 4 Additive 0.00 ============================Request: 55 - I61200 - Tank Siphon Manifold partnersRequest Source: Monitor System Configuration Requests - Line: 55 _________________________ I61200MAY 16, 2018 4:06 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 Unleaded NONE NONE 2 Unleaded NONE NONE 3 Premium NONE NONE 4 Additive NONE NONE ============================Request: 56 - I63600 - Tank Periodic Leak Test Minimum VolumeRequest Source: Monitor System Configuration Requests - Line: 56 _________________________ I63600MAY 16, 2018 4:06 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 Unleaded 24034 2 Unleaded 24034 3 Premium 24066 4 Additive 0 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] ============================Request: 57 - I62A00 - Tank Annual Leak Test Minimum VolumeRequest Source: Monitor System Configuration Requests - Line: 57 _________________________ I62A00MAY 16, 2018 4:06 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 Unleaded 24034 2 Unleaded 24034 3 Premium 24066 4 Additive 0 ============================Request: 58 - I62C00 - Tank Periodic Test TypeRequest Source: Monitor System Configuration Requests - Line: 58 _________________________ I62C00MAY 16, 2018 4:06 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 Unleaded STANDARD 2 Unleaded STANDARD 3 Premium STANDARD 4 Additive STANDARD ============================Request: 59 - I62D00 - Enable-Disable Tank Test Leak Fail AlarmsRequest Source: Monitor System Configuration Requests - Line: 59 _________________________ I62D00MAY 16, 2018 4:07 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 Unleaded GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 Unleaded GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 Premium GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] ANNUAL TEST FAIL ALARM DISABLED 4 Additive GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ============================Request: 60 - I63100 - Tank Leak Test AveragingRequest Source: Monitor System Configuration Requests - Line: 60 _________________________ I63100MAY 16, 2018 4:07 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 Unleaded OFF OFF 2 Unleaded OFF OFF 3 Premium OFF OFF 4 Additive OFF OFF ============================Request: 61 - I63000 - Tank Leak Test notifyRequest Source: Monitor System Configuration Requests - Line: 61 _________________________ I63000MAY 16, 2018 4:07 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 Unleaded OFF 2 Unleaded OFF 3 Premium OFF 4 Additive OFF ============================Request: 62 - I63200 - Tank Test Siphon BreakRequest Source: Monitor System Configuration Requests - Line: 62 _________________________ I63200MAY 16, 2018 4:07 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 Unleaded OFF 2 Unleaded OFF file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] 3 Premium OFF 4 Additive OFF ============================Request: 63 - I61000 - Tank delivery DelayRequest Source: Monitor System Configuration Requests - Line: 63 _________________________ I61000MAY 16, 2018 4:07 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 Unleaded 1 2 Unleaded 1 3 Premium 1 4 Additive 1 ============================Request: 64 - I63A00 - Tank low Level Threshold for Line Manifold Request Source: Monitor System Configuration Requests - Line: 64 _________________________ I63A00MAY 16, 2018 4:07 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 Unleaded 10.00% 2 Unleaded 10.00% 3 Premium 10.00% 4 Additive 10.00% ============================Request: 65 - I61100 - Tank Leak Test Type and Start TimeRequest Source: Monitor System Configuration Requests - Line: 65 _________________________ I61100MAY 16, 2018 4:07 PM LEAK TEST METHOD- - - - - - - - - - - -TEST ON DATE : ALL TANKJUN 7, 2013START TIME : DISABLEDTEST RATE :0.20 GAL/HRDURATION : 2 HOURS TST EARLY STOP:DISABLED file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] ============================Request: 66 - I61300 - CSLD Probability of DetectionRequest Source: Monitor System Configuration Requests - Line: 66 _________________________ I61300MAY 16, 2018 4:07 PMCSLD PROBABLITY OF DETECTION ============================Request: 67 - I61400 - CSLD Climate FactorRequest Source: Monitor System Configuration Requests - Line: 67 _________________________ I61400MAY 16, 2018 4:07 PMCSLD CLIMATE FACTOR ============================Request: 68 - I61600 - Accuchart Update SchedulingRequest Source: Monitor System Configuration Requests - Line: 68 _________________________ I61600MAY 16, 2018 4:07 PM TANK PRODUCT LABEL CAL UPDATE 1 Unleaded NEVER 2 Unleaded NEVER 3 Premium NEVER 4 Additive NEVER ============================Request: 69 - I61A00 - In-Tank Leak Test Early StopRequest Source: Monitor System Configuration Requests - Line: 69 _________________________ I61A00MAY 16, 2018 4:07 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 Unleaded DISABLED 2 Unleaded DISABLED 3 Premium DISABLED file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] 4 Additive DISABLED ============================Request: 70 - I61B00 - In-Tank Static Gross Test Auto-ConfirmRequest Source: Monitor System Configuration Requests - Line: 70 _________________________ I61B00MAY 16, 2018 4:07 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM ============================Request: 71 - I61C00 - CSLD Report Only modeRequest Source: Monitor System Configuration Requests - Line: 71 _________________________ I61C00MAY 16, 2018 4:07 PM CSLD REPORT ONLY ============================Request: 72 - I62B00 - Tank Last Annual TestRequest Source: Monitor System Configuration Requests - Line: 72 _________________________ I62B00MAY 16, 2018 4:07 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 Unleaded ??? 0, 0 2 Unleaded ??? 0, 0 3 Premium ??? 0, 0 4 Additive ??? 0, 0 ============================Request: 73 - I63300 - Leak Test Report TypeRequest Source: Monitor System Configuration Requests - Line: 73 _________________________ I63300MAY 16, 2018 4:07 PM LEAK TEST REPORT FORMAT: NORMAL file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] ============================Request: 74 - I63400 - Tank HRM Reconciliation Warning limitRequest Source: Monitor System Configuration Requests - Line: 74 _________________________ I63400MAY 16, 2018 4:07 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 0 2 Unleaded 0 3 Premium 0 4 Additive 0 ============================Request: 75 - I63500 - Tank HEM Reconciliation AlarmRequest Source: Monitor System Configuration Requests - Line: 75 _________________________ I63500MAY 16, 2018 4:07 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 1 2 Unleaded 1 3 Premium 1 4 Additive 1 ============================Request: 76 - I63900 - Tank Accuchart End Shape Type and FactorRequest Source: Monitor System Configuration Requests - Line: 76 _________________________ I63900MAY 16, 2018 4:07 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 Unleaded END FACTOR: OTHEREND VALUE: 1.0 2 Unleaded END FACTOR: OTHEREND VALUE: 1.0 3 Premium END FACTOR: OTHER file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] END VALUE: 1.0 4 Additive END FACTOR: HEMISPHER ============================Request: 77 - I78000 - PLLD SetupRequest Source: Monitor System Configuration Requests - Line: 77 _________________________ I78000MAY 16, 2018 4:07 PM PRESSURE LINE LEAK SETUP Q 1:UNLEADED 87A TYP:2.0/3.0IN FIBERGLASS2.0IN DIA LEN: 310 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV0.10 GPH TEST: AUTOSHUTDOWN RATE: 3.0 GPHLOW PRESSURE SHUTOFF:YESLOW PRESSURE : 5 PSI T 1:Unleaded DISPENSE MODE: STANDARDSENSOR: NON-VENTEDPRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 2:UNLEADED 87B TYP:2.0/3.0IN FIBERGLASS2.0IN DIA LEN: 320 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV0.10 GPH TEST: AUTOSHUTDOWN RATE: 3.0 GPHLOW PRESSURE SHUTOFF:YESLOW PRESSURE : 5 PSI T 2:Unleaded DISPENSE MODE: STANDARDSENSOR: NON-VENTEDPRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] Q 3:PREMIUM TYP:2.0/3.0IN FIBERGLASS2.0IN DIA LEN: 330 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV0.10 GPH TEST: AUTOSHUTDOWN RATE: 3.0 GPHLOW PRESSURE SHUTOFF:YESLOW PRESSURE : 5 PSI T 3:Premium DISPENSE MODE: STANDARDSENSOR: NON-VENTEDPRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO ============================Request: 78 - I77700 - PLLD Primary Line DiameterRequest Source: Monitor System Configuration Requests - Line: 78 _________________________ I77700MAY 16, 2018 4:08 PM ============================Request: 79 - I77800 - PLLD Secondary Line DiameterRequest Source: Monitor System Configuration Requests - Line: 79 _________________________ I77800MAY 16, 2018 4:08 PM ============================Request: 80 - I78C00 - PLLD 0.20 GPH Test ScheduleRequest Source: Monitor System Configuration Requests - Line: 80 _________________________ I78C00MAY 16, 2018 4:08 PM PRESSURE LINE LEAK 0.20 TEST SCHEDULE LINE 0.20 GPH TESTQ 1:UNLEADED 87A REPETITIVQ 2:UNLEADED 87B REPETITIVQ 3:PREMIUM REPETITIV file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] ============================Request: 81 - I78300 - PLLD 0.10 GPH Test ScheduleRequest Source: Monitor System Configuration Requests - Line: 81 _________________________ I78300MAY 16, 2018 4:08 PM PRESSURE LINE LEAK 0.10 TEST SCHEDULE LINE 0.10 GPH TESTQ 1:UNLEADED 87A AUTOQ 2:UNLEADED 87B AUTOQ 3:PREMIUM AUTO ============================Request: 82 - I78F00 - PLLD Dispense ThresholdRequest Source: Monitor System Configuration Requests - Line: 82 _________________________ I78F00MAY 16, 2018 4:08 PM PRESSURE LINE LEAK DISPENSE THRESHOLD LINE LOW PRESSUREQ 1:UNLEADED 87A 5 PSIQ 2:UNLEADED 87B 5 PSIQ 3:PREMIUM 5 PSI ============================Request: 83 - I78700 - PLLD Disable Alarm AssignmentsRequest Source: Monitor System Configuration Requests - Line: 83 _________________________ I78700MAY 16, 2018 4:08 PM PRESSURE LLD SETUP REPORT Q 1:UNLEADED 87A IN-TANK ALARMS T 1:HIGH WATER ALARM T 2:HIGH WATER ALARM T 1:LOW PRODUCT ALARM T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L17:FUEL ALARM L18:FUEL ALARM L19:FUEL ALARM L21:FUEL ALARM L23:FUEL ALARM L 1:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L17:SENSOR OUT ALARM L18:SENSOR OUT ALARM L19:SENSOR OUT ALARM L21:SENSOR OUT ALARM L23:SENSOR OUT ALARM L 1:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM L17:SHORT ALARM L18:SHORT ALARM L19:SHORT ALARM L21:SHORT ALARM L23:SHORT ALARM L 1:HIGH LIQUID ALARM L 9:HIGH LIQUID ALARM L10:HIGH LIQUID ALARM L11:HIGH LIQUID ALARM L12:HIGH LIQUID ALARM L13:HIGH LIQUID ALARM L14:HIGH LIQUID ALARM L15:HIGH LIQUID ALARM L16:HIGH LIQUID ALARM L17:HIGH LIQUID ALARM L18:HIGH LIQUID ALARM L19:HIGH LIQUID ALARM L21:HIGH LIQUID ALARM L23:HIGH LIQUID ALARM L 1:LOW LIQUID ALARM L 9:LOW LIQUID ALARM L10:LOW LIQUID ALARM L11:LOW LIQUID ALARM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] L12:LOW LIQUID ALARM L13:LOW LIQUID ALARM L14:LOW LIQUID ALARM L15:LOW LIQUID ALARM L16:LOW LIQUID ALARM L17:LOW LIQUID ALARM L18:LOW LIQUID ALARM L19:LOW LIQUID ALARM L21:LOW LIQUID ALARM L23:LOW LIQUID ALARM L 1:LIQUID WARNING L 9:LIQUID WARNING L10:LIQUID WARNING L11:LIQUID WARNING L12:LIQUID WARNING L13:LIQUID WARNING L14:LIQUID WARNING L15:LIQUID WARNING L16:LIQUID WARNING L17:LIQUID WARNING L18:LIQUID WARNING L19:LIQUID WARNING L21:LIQUID WARNING L23:LIQUID WARNING PRESSURE LINE LEAK ALL:PLLD OPEN ALARM ALL:CONT HANDLE ALM ALL:LN EQUIP FAULT ALM SMARTSENSOR ALARMS s 1:SETUP DATA WARNING s 2:SETUP DATA WARNING s 3:SETUP DATA WARNING s11:SETUP DATA WARNING s13:SETUP DATA WARNING s 1:COMMUNICATION ALARM s 2:COMMUNICATION ALARM s 3:COMMUNICATION ALARM s11:COMMUNICATION ALARM s13:COMMUNICATION ALARM s 1:SENSOR FAULT ALARM s 2:SENSOR FAULT ALARM s 3:SENSOR FAULT ALARM s11:SENSOR FAULT ALARM s13:SENSOR FAULT ALARM s11:FUEL WARNING s13:FUEL WARNING s11:FUEL ALARM s13:FUEL ALARM s11:WATER WARNING s13:WATER WARNING s11:WATER ALARM s13:WATER ALARM s 1:HIGH LIQUID WARNING s 2:HIGH LIQUID WARNING s 3:HIGH LIQUID WARNING file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] s11:HIGH LIQUID WARNING s13:HIGH LIQUID WARNING s 1:HIGH LIQUID ALARM s 2:HIGH LIQUID ALARM s 3:HIGH LIQUID ALARM s11:HIGH LIQUID ALARM s13:HIGH LIQUID ALARM s11:LOW LIQUID WARNING s13:LOW LIQUID WARNING s11:LOW LIQUID ALARM s13:LOW LIQUID ALARM s11:INSTALL ALARM s13:INSTALL ALARM s 1:SENSOR FAULT WARN s 2:SENSOR FAULT WARN s 3:SENSOR FAULT WARN s11:SENSOR FAULT WARN s13:SENSOR FAULT WARN s 1:VACUUM WARNING s 2:VACUUM WARNING s 3:VACUUM WARNING s 1:NO VACUUM ALARM s 2:NO VACUUM ALARM s 3:NO VACUUM ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL PC-ISD FAILURE Q 2:UNLEADED 87B IN-TANK ALARMS T 1:HIGH WATER ALARM T 2:HIGH WATER ALARM T 1:LOW PRODUCT ALARM T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 2:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L17:FUEL ALARM L19:FUEL ALARM L21:FUEL ALARM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] L 2:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L17:SENSOR OUT ALARM L19:SENSOR OUT ALARM L21:SENSOR OUT ALARM L 2:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM L17:SHORT ALARM L19:SHORT ALARM L21:SHORT ALARM L 2:HIGH LIQUID ALARM L 9:HIGH LIQUID ALARM L10:HIGH LIQUID ALARM L11:HIGH LIQUID ALARM L12:HIGH LIQUID ALARM L13:HIGH LIQUID ALARM L14:HIGH LIQUID ALARM L15:HIGH LIQUID ALARM L16:HIGH LIQUID ALARM L17:HIGH LIQUID ALARM L19:HIGH LIQUID ALARM L21:HIGH LIQUID ALARM L 2:LOW LIQUID ALARM L 9:LOW LIQUID ALARM L10:LOW LIQUID ALARM L11:LOW LIQUID ALARM L12:LOW LIQUID ALARM L13:LOW LIQUID ALARM L14:LOW LIQUID ALARM L15:LOW LIQUID ALARM L16:LOW LIQUID ALARM L17:LOW LIQUID ALARM L19:LOW LIQUID ALARM L21:LOW LIQUID ALARM L 2:LIQUID WARNING L 9:LIQUID WARNING L10:LIQUID WARNING L11:LIQUID WARNING L12:LIQUID WARNING L13:LIQUID WARNING L14:LIQUID WARNING L15:LIQUID WARNING L16:LIQUID WARNING file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] L17:LIQUID WARNING L19:LIQUID WARNING L21:LIQUID WARNING PRESSURE LINE LEAK ALL:PLLD OPEN ALARM ALL:CONT HANDLE ALM ALL:LN EQUIP FAULT ALM SMARTSENSOR ALARMS s 4:SETUP DATA WARNING s 5:SETUP DATA WARNING s 6:SETUP DATA WARNING s11:SETUP DATA WARNING s13:SETUP DATA WARNING s 4:COMMUNICATION ALARM s 5:COMMUNICATION ALARM s 6:COMMUNICATION ALARM s11:COMMUNICATION ALARM s13:COMMUNICATION ALARM s 4:SENSOR FAULT ALARM s 5:SENSOR FAULT ALARM s 6:SENSOR FAULT ALARM s11:SENSOR FAULT ALARM s13:SENSOR FAULT ALARM s11:FUEL WARNING s13:FUEL WARNING s11:FUEL ALARM s13:FUEL ALARM s11:WATER WARNING s13:WATER WARNING s11:WATER ALARM s13:WATER ALARM s 4:HIGH LIQUID WARNING s 5:HIGH LIQUID WARNING s 6:HIGH LIQUID WARNING s11:HIGH LIQUID WARNING s13:HIGH LIQUID WARNING s 4:HIGH LIQUID ALARM s 5:HIGH LIQUID ALARM s 6:HIGH LIQUID ALARM s11:HIGH LIQUID ALARM s13:HIGH LIQUID ALARM s11:LOW LIQUID ALARM s13:LOW LIQUID ALARM s11:INSTALL ALARM s13:INSTALL ALARM s 4:SENSOR FAULT WARN s 5:SENSOR FAULT WARN s 6:SENSOR FAULT WARN s11:SENSOR FAULT WARN s13:SENSOR FAULT WARN s 4:VACUUM WARNING s 5:VACUUM WARNING s 6:VACUUM WARNING s13:VACUUM WARNING s 4:NO VACUUM ALARM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] s 5:NO VACUUM ALARM s 6:NO VACUUM ALARM s13:NO VACUUM ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL PC-ISD FAILURE Q 3:PREMIUM IN-TANK ALARMS T 3:HIGH WATER ALARM T 3:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 3:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L22:FUEL ALARM L23:FUEL ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L22:SENSOR OUT ALARM L23:SENSOR OUT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM L22:SHORT ALARM L23:SHORT ALARM L 3:HIGH LIQUID ALARM L 9:HIGH LIQUID ALARM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] L10:HIGH LIQUID ALARM L11:HIGH LIQUID ALARM L12:HIGH LIQUID ALARM L13:HIGH LIQUID ALARM L14:HIGH LIQUID ALARM L15:HIGH LIQUID ALARM L16:HIGH LIQUID ALARM L22:HIGH LIQUID ALARM L23:HIGH LIQUID ALARM L 3:LOW LIQUID ALARM L 9:LOW LIQUID ALARM L10:LOW LIQUID ALARM L11:LOW LIQUID ALARM L12:LOW LIQUID ALARM L13:LOW LIQUID ALARM L14:LOW LIQUID ALARM L15:LOW LIQUID ALARM L16:LOW LIQUID ALARM L22:LOW LIQUID ALARM L23:LOW LIQUID ALARM L 3:LIQUID WARNING L 9:LIQUID WARNING L10:LIQUID WARNING L11:LIQUID WARNING L12:LIQUID WARNING L13:LIQUID WARNING L14:LIQUID WARNING L15:LIQUID WARNING L16:LIQUID WARNING L22:LIQUID WARNING L23:LIQUID WARNING PRESSURE LINE LEAK ALL:PLLD OPEN ALARM ALL:CONT HANDLE ALM ALL:LN EQUIP FAULT ALM SMARTSENSOR ALARMS s 9:SETUP DATA WARNING s10:SETUP DATA WARNING s15:SETUP DATA WARNING s 9:COMMUNICATION ALARM s10:COMMUNICATION ALARM s15:COMMUNICATION ALARM s 9:SENSOR FAULT ALARM s10:SENSOR FAULT ALARM s15:SENSOR FAULT ALARM s15:FUEL WARNING s15:FUEL ALARM s15:WATER WARNING s15:WATER ALARM s 9:HIGH LIQUID WARNING s10:HIGH LIQUID WARNING s15:HIGH LIQUID WARNING s 9:HIGH LIQUID ALARM s10:HIGH LIQUID ALARM s15:HIGH LIQUID ALARM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] s15:LOW LIQUID ALARM s15:INSTALL ALARM s 9:SENSOR FAULT WARN s10:SENSOR FAULT WARN s15:SENSOR FAULT WARN s 9:VACUUM WARNING s10:VACUUM WARNING s 9:NO VACUUM ALARM s10:NO VACUUM ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL PC-ISD FAILURE ============================Request: 84 - I70200 - Liquid Sensor Location LabelRequest Source: Monitor System Configuration Requests - Line: 84 _________________________ I70200MAY 16, 2018 4:10 PM LIQUID LABEL DEVICE LABEL 1 UNLEADED 87A ANNULAR 2 UNLEADED 87B ANNULAR 3 PREMIUM ANNULAR 4 ADDITIVE ANNULAR 5 ADDITIVE SUMP 6 ADDITIVE VENT BOX 7 8 9 DISP PAN 1-2 10 DISP PAN 3-4 11 DISP PAN 5-6 12 DISP PAN 7-8 13 DISP PAN 9-10 14 DISP PAN 11-12 15 DISP PAN 13-14 16 DISP PAN 15-16 17 UNL 87A STP BRINE 18 UNL 87A FILL 19 UNL 87B STP BRINE 20 21 UNL 87B FILL 22 91 STP BRINE file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] 23 91 FILL 24 PERMEATOR ============================Request: 85 - I70300 - Liquid Sensor TypeRequest Source: Monitor System Configuration Requests - Line: 85 _________________________ I70300MAY 16, 2018 4:10 PM LIQUID TYPE SENSOR LOCATION TYPE 1 UNLEADED 87A ANNULAR DUAL POINT HYDROSTATIC 2 UNLEADED 87B ANNULAR DUAL POINT HYDROSTATIC 3 PREMIUM ANNULAR DUAL POINT HYDROSTATIC 4 ADDITIVE ANNULAR DUAL POINT HYDROSTATIC 5 ADDITIVE SUMP DW SUMP 2-1 6 ADDITIVE VENT BOX DW SUMP 2-1 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) 9 DISP PAN 1-2 DW SUMP 2-1 10 DISP PAN 3-4 DW SUMP 2-1 11 DISP PAN 5-6 DW SUMP 2-1 12 DISP PAN 7-8 DW SUMP 2-1 13 DISP PAN 9-10 DW SUMP 2-1 14 DISP PAN 11-12 DW SUMP 2-1 15 DISP PAN 13-14 DW SUMP 2-1 16 DISP PAN 15-16 DW SUMP 2-1 17 UNL 87A STP BRINE TRI-STATE (SINGLE FLOAT) 18 UNL 87A FILL DW SUMP 2-1 19 UNL 87B STP BRINE TRI-STATE (SINGLE FLOAT) 20 TRI-STATE (SINGLE FLOAT) 21 UNL 87B FILL DW SUMP 2-1 22 91 STP BRINE TRI-STATE (SINGLE FLOAT) 23 91 FILL DW SUMP 2-1 24 PERMEATOR NORMALLY CLOSED ============================Request: 86 - I70400 - Liquid Sensor CategoryRequest Source: Monitor System Configuration Requests - Line: 86 _________________________ I70400MAY 16, 2018 4:10 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNLEADED 87A ANNULAR ANNULAR SPACE 2 UNLEADED 87B ANNULAR ANNULAR SPACE 3 PREMIUM ANNULAR ANNULAR SPACE file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] 4 ADDITIVE ANNULAR ANNULAR SPACE 5 ADDITIVE SUMP STP SUMP 6 ADDITIVE VENT BOX DISPENSER PAN 7 OTHER SENSORS 8 OTHER SENSORS 9 DISP PAN 1-2 DISPENSER PAN 10 DISP PAN 3-4 DISPENSER PAN 11 DISP PAN 5-6 DISPENSER PAN 12 DISP PAN 7-8 DISPENSER PAN 13 DISP PAN 9-10 DISPENSER PAN 14 DISP PAN 11-12 DISPENSER PAN 15 DISP PAN 13-14 DISPENSER PAN 16 DISP PAN 15-16 DISPENSER PAN 17 UNL 87A STP BRINE ANNULAR SPACE 18 UNL 87A FILL OTHER SENSORS 19 UNL 87B STP BRINE ANNULAR SPACE 20 OTHER SENSORS 21 UNL 87B FILL OTHER SENSORS 22 91 STP BRINE ANNULAR SPACE 23 91 FILL ANNULAR SPACE 24 PERMEATOR OTHER SENSORS ============================Request: 87 - I74200 - Type "A" 2 Wire Sensor Location LabelRequest Source: Monitor System Configuration Requests - Line: 87 _________________________ I74200MAY 16, 2018 4:10 PM ============================Request: 88 - I74300 - Type "A" 2 Wire Sensor TypeRequest Source: Monitor System Configuration Requests - Line: 88 _________________________ I74300MAY 16, 2018 4:10 PM ============================Request: 89 - I74400 - Type "A" 2 Wire Sensor CategoryRequest Source: Monitor System Configuration Requests - Line: 89 _________________________ I74400MAY 16, 2018 4:10 PM ============================Request: 90 - I74700 - Type "B" 3 Wire Sensor Location LabelRequest Source: Monitor System Configuration Requests - Line: 90 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] _________________________ I74700MAY 16, 2018 4:10 PM ============================Request: 91 - I74800 - Type "B" 3 Wire Sensor TypeRequest Source: Monitor System Configuration Requests - Line: 91 _________________________ I74800MAY 16, 2018 4:10 PM ============================Request: 92 - I74900 - Type "B" Sensor CategoryRequest Source: Monitor System Configuration Requests - Line: 92 _________________________ I74900MAY 16, 2018 4:10 PM ============================Request: 93 - I7BC00 - I/O Device Line Disable AssignmentsRequest Source: Monitor System Configuration Requests - Line: 93 _________________________ I7BC00MAY 16, 2018 4:10 PM ============================Request: 94 - I80200 - I/O Input location LabelRequest Source: Monitor System Configuration Requests - Line: 94 _________________________ I80200MAY 16, 2018 4:10 PM ============================Request: 95 - I80300 - I/O Input TypeRequest Source: Monitor System Configuration Requests - Line: 95 _________________________ I80300MAY 16, 2018 4:10 PM ============================ file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] Request: 96 - I80400 - I/O Input Dispense modeRequest Source: Monitor System Configuration Requests - Line: 96 _________________________ I80400MAY 16, 2018 4:10 PM ============================Request: 97 - I80700 - I/O Relay location labelRequest Source: Monitor System Configuration Requests - Line: 97 _________________________ I80700MAY 16, 2018 4:10 PM RELAY LABEL DEVICE LABEL 1 DATA HUT V-R ALARM 2 WAREHOUSE V-R ALARM 3 ADDITIVE SHUTDOWN 4 ============================Request: 98 - I80900 - I/O Relay OrientationRequest Source: Monitor System Configuration Requests - Line: 98 _________________________ I80900MAY 16, 2018 4:11 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 DATA HUT V-R ALARM NORMALLY OPEN 2 WAREHOUSE V-R ALARM NORMALLY OPEN 3 ADDITIVE SHUTDOWN NORMALLY OPEN 4 NORMALLY OPEN ============================Request: 99 - I80B00 - I/O Relay Tank AssignmentRequest Source: Monitor System Configuration Requests - Line: 99 _________________________ I80B00MAY 16, 2018 4:11 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] 1 DATA HUT V-R ALARM NONE 2 WAREHOUSE V-R ALARM NONE 3 ADDITIVE SHUTDOWN 4 4 NONE ============================Request: 100 - I80A00 - I/O Relay TypeRequest Source: Monitor System Configuration Requests - Line: 100 _________________________ I80A00MAY 16, 2018 4:11 PM RELAY TYPE RELAY DESIGNATION TYPE 1 DATA HUT V-R ALARM STANDARD 2 WAREHOUSE V-R ALARM STANDARD 3 ADDITIVE SHUTDOWN PUMP CONTROL OUTPUT 4 STANDARD ============================Request: 101 - I80C00 - I/O External input TypeRequest Source: Monitor System Configuration Requests - Line: 101 _________________________ I80C00MAY 16, 2018 4:11 PM ============================Request: 102 - I80800 - I/O Relay Alarm AssignmentsRequest Source: Monitor System Configuration Requests - Line: 102 _________________________ I80800MAY 16, 2018 4:11 PM RELAY SETUP REPORT R 1:DATA HUT V-R ALARM TYPE: STANDARDNORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:HIGH WATER ALARM ALL:OVERFILL ALARM ALL:LOW PRODUCT ALARM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] ALL:SUDDEN LOSS ALARM ALL:HIGH PRODUCT ALARM ALL:INVALID FUEL LEVEL ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED ALL:MAX PRODUCT ALARM ALL:LOW TEMP WARNING ALL:FUEL QUALITY ALARM LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM ALL:HIGH LIQUID ALARM ALL:LOW LIQUID ALARM ALL:LIQUID WARNING PRESSURE LINE LEAK ALL:GROSS LINE FAIL ALL:ANNUAL LINE FAIL ALL:PER TST NEEDED WRN ALL:PER TST NEEDED ALM ALL:PLLD OPEN ALARM ALL:PLLD SHUTDOWN ALARM ALL:PERIODIC LINE FAIL ALL:ANN TST NEEDED WRN ALL:ANN TST NEEDED ALM ALL:LOW PRESSURE ALARM ALL:CONT HANDLE ALM ALL:FUEL OUT ALL:LN EQUIP FAULT ALM ALL:GRS TST NEEDED ALM SMARTSENSOR ALARMS ALL:SETUP DATA WARNING ALL:COMMUNICATION ALARM ALL:SENSOR FAULT ALARM ALL:FUEL WARNING ALL:FUEL ALARM ALL:WATER WARNING ALL:WATER ALARM ALL:HIGH LIQUID WARNING ALL:HIGH LIQUID ALARM ALL:LOW LIQUID WARNING ALL:LOW LIQUID ALARM ALL:TEMPERATURE WARNING ALL:RELAY ACTIVE ALL:INSTALL ALARM ALL:SENSOR FAULT WARN ALL:VACUUM WARNING ALL:NO VACUUM ALARM ALL:BATTERY WARNING ISD SITE ALARMS ISD STAGE I WARN ISD GROSS PRES WARN file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] ISD GROSS PRES FAIL ISD DEGRD PRES WARN ISD DEGRD PRES FAIL ISD VAPOR LEAK WARN ISD VAPOR LEAK FAIL ISD VP PRES WARN ISD VP PRES FAIL ISD VP STATUS WARN ISD VP STATUS FAIL MISSING RELAY SETUP MISSING HOSE SETUP MISSING TANK SETUP MISS VAPOR FLOW MTR MISS VAPOR PRES SEN MISSING VP INPUT ISD SETUP WARN ISD SETUP FAIL ISD SENSOR OUT WARN ISD SENSOR OUT FAIL PC-ISD FAILURE PMC ALARMS VP RUNTIME FAULT VP EMISSIONS WARN VP EMISSIONS FAIL VP PRESSURE WARN VP PRESSURE FAIL VP DUTY CYCLE WARN VP DUTY CYCLE FAIL PMC SETUP FAIL PMC SENSOR FAULT R 2:WAREHOUSE V-R ALARM TYPE: STANDARDNORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:HIGH WATER ALARM ALL:OVERFILL ALARM ALL:LOW PRODUCT ALARM ALL:SUDDEN LOSS ALARM ALL:HIGH PRODUCT ALARM ALL:INVALID FUEL LEVEL ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED ALL:MAX PRODUCT ALARM ALL:LOW TEMP WARNING ALL:FUEL QUALITY ALARM LIQUID SENSOR ALMS ALL:FUEL ALARM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] ALL:SENSOR OUT ALARM ALL:SHORT ALARM ALL:HIGH LIQUID ALARM ALL:LOW LIQUID ALARM ALL:LIQUID WARNING PRESSURE LINE LEAK ALL:GROSS LINE FAIL ALL:ANNUAL LINE FAIL ALL:PER TST NEEDED WRN ALL:PER TST NEEDED ALM ALL:PLLD OPEN ALARM ALL:PLLD SHUTDOWN ALARM ALL:PERIODIC LINE FAIL ALL:ANN TST NEEDED WRN ALL:ANN TST NEEDED ALM ALL:LOW PRESSURE ALARM ALL:CONT HANDLE ALM ALL:FUEL OUT ALL:LN EQUIP FAULT ALM ALL:GRS TST NEEDED ALM SMARTSENSOR ALARMS ALL:SETUP DATA WARNING ALL:COMMUNICATION ALARM ALL:SENSOR FAULT ALARM ALL:FUEL WARNING ALL:FUEL ALARM ALL:WATER WARNING ALL:WATER ALARM ALL:HIGH LIQUID WARNING ALL:HIGH LIQUID ALARM ALL:LOW LIQUID WARNING ALL:LOW LIQUID ALARM ALL:TEMPERATURE WARNING ALL:RELAY ACTIVE ALL:INSTALL ALARM ALL:SENSOR FAULT WARN ALL:VACUUM WARNING ALL:NO VACUUM ALARM ALL:BATTERY WARNING ISD SITE ALARMS ISD STAGE I WARN ISD GROSS PRES WARN ISD GROSS PRES FAIL ISD DEGRD PRES WARN ISD DEGRD PRES FAIL ISD VAPOR LEAK WARN ISD VAPOR LEAK FAIL ISD VP PRES WARN ISD VP PRES FAIL ISD VP STATUS WARN ISD VP STATUS FAIL MISSING RELAY SETUP MISSING HOSE SETUP MISSING TANK SETUP file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] MISS VAPOR FLOW MTR MISS VAPOR PRES SEN MISSING VP INPUT ISD SETUP WARN ISD SETUP FAIL ISD SENSOR OUT WARN ISD SENSOR OUT FAIL PC-ISD FAILURE PMC ALARMS VP RUNTIME FAULT VP EMISSIONS WARN VP EMISSIONS FAIL VP PRESSURE WARN VP PRESSURE FAIL VP DUTY CYCLE WARN VP DUTY CYCLE FAIL PMC SETUP FAIL PMC SENSOR FAULT R 3:ADDITIVE SHUTDOWN TYPE: PUMP CONTROL OUTPUTTANK #: 4 IN-TANK ALARMS T 4:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 4:HIGH LIQUID ALARM L 5:HIGH LIQUID ALARM L 6:HIGH LIQUID ALARM L 4:LOW LIQUID ALARM L 5:LOW LIQUID ALARM L 6:LOW LIQUID ALARM L 4:LIQUID WARNING L 5:LIQUID WARNING L 6:LIQUID WARNING SMARTSENSOR ALARMS s12:COMMUNICATION ALARM s14:COMMUNICATION ALARM s12:SENSOR FAULT ALARM s14:SENSOR FAULT ALARM s12:HIGH LIQUID WARNING s14:HIGH LIQUID WARNING file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] s12:HIGH LIQUID ALARM s14:HIGH LIQUID ALARM s12:SENSOR FAULT WARN s14:SENSOR FAULT WARN s12:VACUUM WARNING s14:VACUUM WARNING s12:NO VACUUM ALARM s14:NO VACUUM ALARM R 4: TYPE: STANDARDNORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - ============================Request: 103 - I79000 - DIM Software RevisionRequest Source: Monitor System Configuration Requests - Line: 103 _________________________ I79000MAY 16, 2018 4:12 PM EDIM:1 VR:330273-002-C TD:97.11.13.15.52 ============================Request: 104 - I79100 - Mechanical Dispenser Interface StringRequest Source: Monitor System Configuration Requests - Line: 104 _________________________ I79100MAY 16, 2018 4:12 PM ============================Request: 105 - I72300 - Smart Sensor CategoryRequest Source: Monitor System Configuration Requests - Line: 105 _________________________ I72300MAY 16, 2018 4:12 PM 279395 COSTCO 6434900 PANAMA LANE BAKERSFIELD, CA file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY01 UNL 87A PRODUCT LINE VAC SENSOR02 VAPOR LINE VAC SENSOR03 UNL 87A VENT LINE VAC SENSOR04 UNL 87B PRODUCT LINE VAC SENSOR05 UNL 87B SIPHON LINE VAC SENSOR06 UNL 87B VENT LINE VAC SENSOR07 PRESSURE SENSOR 3-4 VAPOR PRESSURE08 ATP ATM P SENSOR09 PREMIUM PRODUCT LINE VAC SENSOR10 PREMIUM VENT LINE VAC SENSOR11 87A STP SUMP MAG SENSOR12 ADDITIVE PRODUCT VAC VAC SENSOR13 87B STP SUMP MAG SENSOR14 ADDITIVE VENT VAC VAC SENSOR15 PREMIUM STP SUMP MAG SENSOR16 UNKNOWN17 DISP 1-2 AIR FLOW METER18 DISP 3-4 AIR FLOW METER19 DISP 5-6 AIR FLOW METER20 DISP 7-8 AIR FLOW METER21 DISP 9-10 AIR FLOW METER22 DISP 11-12 AIR FLOW METER23 DISP 13-14 AIR FLOW METER24 DISP 15-16 AIR FLOW METER25 UNKNOWN26 UNKNOWN27 UNKNOWN28 UNKNOWN29 UNKNOWN30 UNKNOWN31 UNKNOWN32 UNKNOWN33 UNKNOWN34 UNKNOWN35 UNKNOWN36 UNKNOWN37 UNKNOWN38 UNKNOWN39 UNKNOWN40 UNKNOWN ============================Request: 106 - IV4E00 - ISD EVR TypeRequest Source: Monitor System Configuration Requests - Line: 106 _________________________ IV4E00MAY 16, 2018 4:13 PM 279395 COSTCO 6434900 PANAMA LANE file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] BAKERSFIELD, CA EVR/ISD SETUPTYPE: VACUUM ASSISTVACUUM ASSIST TYPE: HEALY VAC ============================Request: 107 - IV4F00 - ISD Nozzle TypeRequest Source: Monitor System Configuration Requests - Line: 107 _________________________ IV4F00MAY 16, 2018 4:13 PM 279395 COSTCO 6434900 PANAMA LANE BAKERSFIELD, CA NOZZLE A/L RANGEA/L RATIO: 0.95 - 1.15 ============================Request: 108 - IV4000 - Vapor Processor TypeRequest Source: Monitor System Configuration Requests - Line: 108 _________________________ IV4000MAY 16, 2018 4:13 PM 279395 COSTCO 6434900 PANAMA LANE BAKERSFIELD, CA VAPOR PROCESSOR TYPENONE ============================Request: 109 - IV4700 - ISD Assessment Start and Post DelayRequest Source: Monitor System Configuration Requests - Line: 109 _________________________ IV4700MAY 16, 2018 4:13 PM 279395 COSTCO 6434900 PANAMA LANE BAKERSFIELD, CA file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] ASSESSMENT TIMESTART TIME: 11:59 PMTIME DELAY MINUTES: 1 ============================Request: 110 - IV5200 - High ORVR ConfigurationRequest Source: Monitor System Configuration Requests - Line: 110 _________________________ IV5200MAY 16, 2018 4:13 PM 279395 COSTCO 6434900 PANAMA LANE BAKERSFIELD, CA ACCEPT HIGH ORVR: NO ============================Request: 111 - IV4A00 - ISD Hose TableRequest Source: Monitor System Configuration Requests - Line: 111 _________________________ IV4A00MAY 16, 2018 4:13 PM 279395 COSTCO 6434900 PANAMA LANE BAKERSFIELD, CA ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 UU BLEND2 02 02 02 01 UU BLEND2 03 03 03 02 UU BLEND2 04 04 04 02 UU BLEND2 05 05 05 03 UU BLEND2 06 06 06 03 UU BLEND2 07 07 07 04 UU BLEND2 08 08 08 04 UU BLEND2 09 09 09 05 UU BLEND2 10 10 10 05 UU BLEND2 11 11 11 06 UU BLEND2 12 12 12 06 UU BLEND2 13 13 13 07 UU BLEND2 14 14 14 07 UU BLEND2 15 15 15 08 UU BLEND2 16 16 16 08 UU BLEND2 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] ============================Request: 112 - IV4B00 - ISD Grade TableRequest Source: Monitor System Configuration Requests - Line: 112 _________________________ IV4B00MAY 16, 2018 4:13 PM 279395 COSTCO 6434900 PANAMA LANE BAKERSFIELD, CA PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H401 01 01/01 02/01 xx/xx xx/xx02 01 01/02 02/02 xx/xx xx/xx03 02 01/03 02/03 xx/xx xx/xx04 02 01/04 02/04 xx/xx xx/xx05 03 01/05 02/05 xx/xx xx/xx06 03 01/06 02/06 xx/xx xx/xx07 04 01/07 02/07 xx/xx xx/xx08 04 01/08 02/08 xx/xx xx/xx09 05 01/09 02/09 xx/xx xx/xx10 05 01/10 02/10 xx/xx xx/xx11 06 01/11 02/11 xx/xx xx/xx12 06 01/12 02/12 xx/xx xx/xx13 07 01/13 02/13 xx/xx xx/xx14 07 01/14 02/14 xx/xx xx/xx15 08 01/15 02/15 xx/xx xx/xx16 08 01/16 02/16 xx/xx xx/xx ============================Request: 113 - IV4900 - ISD Hose Label TableRequest Source: Monitor System Configuration Requests - Line: 113 _________________________ IV4900MAY 16, 2018 4:13 PM 279395 COSTCO 6434900 PANAMA LANE BAKERSFIELD, CA LABEL TABLEID LABEL01 UNASSIGNED02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 ============================Request: 114 - IV1000 - ISD VersionRequest Source: Monitor System Configuration Requests - Line: 114 _________________________ IV1000MAY 16, 2018 4:13 PM ISD VERSION: 01.05 ============================| Next Request Source: || Alarm History Request+==========================+Request: 115 - I10200 - System ConfigurationRequest Source: Alarm History Request - Line: 1 _________________________ I10200MAY 16, 2018 4:14 PM 279395 COSTCO 6434900 PANAMA LANE BAKERSFIELD, CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 163130 163130 2 INTERSTITIAL BD 201225 201225 3 INTERSTITIAL BD 200762 200762 4 7SMARTSENSOR BD 506410 506410 5 INTERSTITIAL BD 200646 200646 6 PLLD SENSOR BD 3888 3888 7 8SMARTSENSOR BD 39280 39280 8 8SMARTSENSOR BD 39345 39345 9 RELAY BOARD 14957 14957 10 PLLD POWER BD 99889 99889 11 UNUSED 5133578 5133578 12 UNUSED 5128135 5128135 13 STP SENSE BOARD 32846 32846 14 UNUSED 5130900 5130900 15 UNUSED 5126849 5126849 16 UNUSED 5127064 5127064 COMM 1 ELEC DISP INT. 100735 100735 COMM 2 SERIAL SAT BD 483383 483383 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] COMM 3 RS232 SERIAL BD 14936 14936 COMM 4 UNUSED 5125049 5125049 COMM 5 UNUSED 5123313 5123313 COMM 6 UNUSED 5123163 5123163 ============================Request: 116 - I90200 - System Revision LevelRequest Source: Alarm History Request - Line: 2 _________________________ I90200MAY 16, 2018 4:14 PMSOFTWARE REVISION LEVELVERSION 333.04SOFTWARE# 346333-100-E CREATED - 13.06.07.08.25 S-MODULE# 330160-164-aSYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS BIR ISD/APMPLLD 0.10 AUTO 0.20 REPETITIVWPLLD 0.10 AUTO 0.20 REPETITIV ============================Request: 117 - I11100 - Priority Alarm HistoryRequest Source: Alarm History Request - Line: 3 _________________________ I11100MAY 16, 2018 4:15 PM 279395 COSTCO 6434900 PANAMA LANE BAKERSFIELD, CA PRIORITY ALARM HISTORYID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIMEQ 3 OTHER PREMIUM PLLD SHUTDOWN ALARM CLEAR 5-16-18 3:22PMQ 3 OTHER PREMIUM GROSS LINE FAIL CLEAR 5-16-18 3:22PMQ 2 OTHER UNLEADED 87B PLLD SHUTDOWN ALARM CLEAR 5-16-18 3:22PMQ 2 OTHER UNLEADED 87B GROSS LINE FAIL CLEAR 5-16-18 3:22PMQ 1 OTHER UNLEADED 87A PLLD SHUTDOWN ALARM CLEAR 5-16-18 3:21PMQ 1 OTHER UNLEADED 87A GROSS LINE FAIL CLEAR 5-16-18 3:21PMQ 2 OTHER UNLEADED 87B PLLD SHUTDOWN ALARM ALARM 5-16-18 3:14PMQ 2 OTHER UNLEADED 87B GROSS LINE FAIL ALARM 5-16-18 3:14PM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] Q 3 OTHER PREMIUM PLLD SHUTDOWN ALARM ALARM 5-16-18 3:01PMQ 3 OTHER PREMIUM GROSS LINE FAIL ALARM 5-16-18 3:01PMQ 1 OTHER UNLEADED 87A PLLD SHUTDOWN ALARM ALARM 5-16-18 2:58PMQ 1 OTHER UNLEADED 87A GROSS LINE FAIL ALARM 5-16-18 2:58PML 5 STP SUMP ADDITIVE SUMP SENSOR OUT ALARM CLEAR 5-16-18 2:46PML 5 STP SUMP ADDITIVE SUMP SENSOR OUT ALARM ALARM 5-16-18 2:45PMT 4 TANK Additive OVERFILL ALARM CLEAR 5-16-18 2:44PMT 4 TANK Additive OVERFILL ALARM ALARM 5-16-18 2:42PMs12 OTHER ADDITIVE PRODUCT VAC NO VACUUM ALARM CLEAR 5-16-18 2:39PMs12 OTHER ADDITIVE PRODUCT VAC NO VACUUM ALARM ALARM 5-16-18 2:39PMs14 OTHER ADDITIVE VENT VAC NO VACUUM ALARM CLEAR 5-16-18 2:38PMs14 OTHER ADDITIVE VENT VAC NO VACUUM ALARM ALARM 5-16-18 2:38PML 5 STP SUMP ADDITIVE SUMP SENSOR OUT ALARM CLEAR 5-16-18 2:37PMs14 OTHER ADDITIVE VENT VAC HIGH LIQUID ALARM CLEAR 5-16-18 2:37PML 5 STP SUMP ADDITIVE SUMP SENSOR OUT ALARM ALARM 5-16-18 2:37PMs12 OTHER ADDITIVE PRODUCT VAC HIGH LIQUID ALARM CLEAR 5-16-18 2:37PMs14 OTHER ADDITIVE VENT VAC HIGH LIQUID ALARM ALARM 5-16-18 2:36PMs12 OTHER ADDITIVE PRODUCT VAC HIGH LIQUID ALARM ALARM 5-16-18 2:36PMs12 OTHER ADDITIVE PRODUCT VAC HIGH LIQUID ALARM CLEAR 5-16-18 2:36PMs12 OTHER ADDITIVE PRODUCT VAC HIGH LIQUID ALARM ALARM 5-16-18 2:35PML 6 DISP PAN ADDITIVE VENT BOX FUEL ALARM CLEAR 5-16-18 2:34PML 6 DISP PAN ADDITIVE VENT BOX SENSOR OUT ALARM CLEAR 5-16-18 2:33PML 6 DISP PAN ADDITIVE VENT BOX FUEL ALARM ALARM 5-16-18 2:33PML 6 DISP PAN ADDITIVE VENT BOX SENSOR OUT ALARM ALARM 5-16-18 2:33PML 6 DISP PAN ADDITIVE VENT BOX LOW LIQUID ALARM CLEAR 5-16-18 2:33PML 6 DISP PAN ADDITIVE VENT BOX LOW LIQUID ALARM ALARM 5-16-18 2:32PML 5 STP SUMP ADDITIVE SUMP FUEL ALARM CLEAR 5-16-18 2:31PML 5 STP SUMP ADDITIVE SUMP FUEL ALARM ALARM 5-16-18 2:31PML 5 STP SUMP ADDITIVE SUMP SENSOR OUT ALARM CLEAR 5-16-18 2:31PML 5 STP SUMP ADDITIVE SUMP SENSOR OUT ALARM ALARM 5-16-18 2:31PML 5 STP SUMP ADDITIVE SUMP LOW LIQUID ALARM CLEAR 5-16-18 2:31PML 5 STP SUMP ADDITIVE SUMP LOW LIQUID ALARM ALARM 5-16-18 2:30PML 4 ANNULAR ADDITIVE ANNULAR LOW LIQUID ALARM CLEAR 5-16-18 2:30PML 4 ANNULAR ADDITIVE ANNULAR LOW LIQUID ALARM ALARM 5-16-18 2:30PML 4 ANNULAR ADDITIVE ANNULAR HIGH LIQUID ALARM CLEAR 5-16-18 2:30PML 4 ANNULAR ADDITIVE ANNULAR HIGH LIQUID ALARM ALARM 5-16-18 2:30PMQ 3 OTHER PREMIUM PLLD SHUTDOWN ALARM CLEAR 5-16-18 2:23PMs10 OTHER PREMIUM VENT LINE NO VACUUM ALARM CLEAR 5-16-18 2:23PMs10 OTHER PREMIUM VENT LINE NO VACUUM ALARM ALARM 5-16-18 2:23PMQ 3 OTHER PREMIUM PLLD SHUTDOWN ALARM ALARM 5-16-18 2:23PMQ 3 OTHER PREMIUM PLLD SHUTDOWN ALARM CLEAR 5-16-18 2:23PMs 9 OTHER PREMIUM PRODUCT LINE NO VACUUM ALARM CLEAR 5-16-18 2:23PM ============================Request: 118 - I11200 - Non-Priority Alarm historyRequest Source: Alarm History Request - Line: 4 _________________________ I11200MAY 16, 2018 4:15 PM 279395 COSTCO 6434900 PANAMA LANE BAKERSFIELD, CA file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] NON-PRIORITY ALARM HISTORYID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIMET 4 TANK Additive HIGH PRODUCT ALARM CLEAR 5-16-18 2:42PMT 4 TANK Additive HIGH PRODUCT ALARM ALARM 5-16-18 2:42PML23 ANNULAR 91 FILL SETUP DATA WARNING CLEAR 5-16-18 1:37PML23 ANNULAR 91 FILL SETUP DATA WARNING ALARM 5-16-18 1:37PMs13 OTHER 87B STP SUMP WATER WARNING CLEAR 5-16-18 1:30PMs13 OTHER 87B STP SUMP WATER WARNING ALARM 5-16-18 1:30PMs11 OTHER 87A STP SUMP WATER WARNING CLEAR 5-16-18 1:28PMs11 OTHER 87A STP SUMP WATER WARNING ALARM 5-16-18 1:28PMs14 OTHER ADDITIVE VENT VAC SETUP DATA WARNING CLEAR 6-07-13 12:06PMs12 OTHER ADDITIVE PRODUCT VAC SETUP DATA WARNING CLEAR 6-07-13 12:06PMs10 OTHER PREMIUM VENT LINE SETUP DATA WARNING CLEAR 6-07-13 12:06PMs 9 OTHER PREMIUM PRODUCT LINE SETUP DATA WARNING CLEAR 6-07-13 12:06PMs 6 OTHER UNL 87B VENT LINE SETUP DATA WARNING CLEAR 6-07-13 12:06PMs 5 OTHER UNL 87B SIPHON LINE SETUP DATA WARNING CLEAR 6-07-13 12:06PMs 4 OTHER UNL 87B PRODUCT LINE SETUP DATA WARNING CLEAR 6-07-13 12:06PMs 3 OTHER UNL 87A VENT LINE SETUP DATA WARNING CLEAR 6-07-13 12:06PMs 2 OTHER VAPOR LINE SETUP DATA WARNING CLEAR 6-07-13 12:05PMs 1 OTHER UNL 87A PRODUCT LINE SETUP DATA WARNING CLEAR 6-07-13 12:05PML24 OTHER PERMEATOR SETUP DATA WARNING CLEAR 6-07-13 11:40AML23 ANNULAR 91 FILL SETUP DATA WARNING CLEAR 6-07-13 11:40AML22 ANNULAR 91 STP BRINE SETUP DATA WARNING CLEAR 6-07-13 11:40AML21 OTHER UNL 87B FILL SETUP DATA WARNING CLEAR 6-07-13 11:40AML19 ANNULAR UNL 87B STP BRINE SETUP DATA WARNING CLEAR 6-07-13 11:40AML18 OTHER UNL 87A FILL SETUP DATA WARNING CLEAR 6-07-13 11:40AML17 ANNULAR UNL 87A STP BRINE SETUP DATA WARNING CLEAR 6-07-13 11:40AML16 DISP PAN DISP PAN 15-16 SETUP DATA WARNING CLEAR 6-07-13 11:40AML15 DISP PAN DISP PAN 13-14 SETUP DATA WARNING CLEAR 6-07-13 11:40AML14 DISP PAN DISP PAN 11-12 SETUP DATA WARNING CLEAR 6-07-13 11:40AML13 DISP PAN DISP PAN 9-10 SETUP DATA WARNING CLEAR 6-07-13 11:40AML12 DISP PAN DISP PAN 7-8 SETUP DATA WARNING CLEAR 6-07-13 11:40AML11 DISP PAN DISP PAN 5-6 SETUP DATA WARNING CLEAR 6-07-13 11:40AML10 DISP PAN DISP PAN 3-4 SETUP DATA WARNING CLEAR 6-07-13 11:40AML 9 DISP PAN DISP PAN 1-2 SETUP DATA WARNING CLEAR 6-07-13 11:40AML 6 DISP PAN ADDITIVE VENT BOX SETUP DATA WARNING CLEAR 6-07-13 11:40AML 5 STP SUMP ADDITIVE SUMP SETUP DATA WARNING CLEAR 6-07-13 11:40AML 4 ANNULAR ADDITIVE ANNULAR SETUP DATA WARNING CLEAR 6-07-13 11:40AML 3 ANNULAR PREMIUM ANNULAR SETUP DATA WARNING CLEAR 6-07-13 11:40AML 2 ANNULAR UNLEADED 87B ANNULAR SETUP DATA WARNING CLEAR 6-07-13 11:40AML 1 ANNULAR UNLEADED 87A ANNULAR SETUP DATA WARNING CLEAR 6-07-13 11:40AMs 1 OTHER UNL 87A PRODUCT LINE SETUP DATA WARNING ALARM 6-07-13 11:10AMs14 OTHER ADDITIVE VENT VAC SETUP DATA WARNING ALARM 6-07-13 11:10AMs12 OTHER ADDITIVE PRODUCT VAC SETUP DATA WARNING ALARM 6-07-13 11:10AMs10 OTHER PREMIUM VENT LINE SETUP DATA WARNING ALARM 6-07-13 11:10AMs 9 OTHER PREMIUM PRODUCT LINE SETUP DATA WARNING ALARM 6-07-13 11:10AMs 6 OTHER UNL 87B VENT LINE SETUP DATA WARNING ALARM 6-07-13 11:10AMs 5 OTHER UNL 87B SIPHON LINE SETUP DATA WARNING ALARM 6-07-13 11:10AMs 4 OTHER UNL 87B PRODUCT LINE SETUP DATA WARNING ALARM 6-07-13 11:10AMs 3 OTHER UNL 87A VENT LINE SETUP DATA WARNING ALARM 6-07-13 11:10AMs 2 OTHER VAPOR LINE SETUP DATA WARNING ALARM 6-07-13 11:10AML24 OTHER PERMEATOR SETUP DATA WARNING ALARM 6-07-13 11:05AM ============================Request: 119 - I20600 - In-Tank Alarm history file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] Request Source: Alarm History Request - Line: 5 _________________________ I20600MAY 16, 2018 4:16 PM 279395 COSTCO 6434900 PANAMA LANE BAKERSFIELD, CA TANK ALARM HISTORY TANK 1 Unleaded OVERFILL ALARM MAY 16, 2018 2:09 PM PROBE OUT MAY 16, 2018 2:10 PM MAY 16, 2018 2:06 PM TANK 2 Unleaded OVERFILL ALARM MAY 16, 2018 2:13 PM PROBE OUT MAY 16, 2018 2:13 PM MAY 16, 2018 2:11 PM TANK 3 Premium OVERFILL ALARM MAY 16, 2018 2:20 PM PROBE OUT MAY 16, 2018 2:20 PM MAY 16, 2018 2:18 PM TANK 4 Additive OVERFILL ALARM MAY 16, 2018 2:42 PM HIGH PRODUCT ALARM MAY 16, 2018 2:42 PM TANK 5 Diesel TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] TANK 13 TANK 14 TANK 15 TANK 16 ============================Request: 120 - I38200 - Pressure line Leak Alarm HistoryRequest Source: Alarm History Request - Line: 6 _________________________ I38200MAY 16, 2018 4:16 PM 279395 COSTCO 6434900 PANAMA LANE BAKERSFIELD, CA PRESSURE LINE LEAK ALARM HISTORY REPORT Q 1:UNLEADED 87A MAY 16, 2018 2:58 PM PLLD SHUTDOWN ALARM MAY 16, 2018 2:58 PM GROSS LINE FAIL MAY 16, 2018 2:05 PM PLLD SHUTDOWN ALARM MAY 16, 2018 2:05 PM PLLD SHUTDOWN ALARM MAY 16, 2018 2:05 PM PLLD SHUTDOWN ALARM MAY 16, 2018 2:03 PM PLLD SHUTDOWN ALARM MAY 16, 2018 2:01 PM PLLD SHUTDOWN ALARM MAY 16, 2018 2:00 PM PLLD SHUTDOWN ALARM MAY 16, 2018 2:00 PM PLLD SHUTDOWN ALARM MAY 16, 2018 1:59 PM PLLD SHUTDOWN ALARM Q 2:UNLEADED 87B MAY 16, 2018 3:14 PM PLLD SHUTDOWN ALARM MAY 16, 2018 3:14 PM GROSS LINE FAIL MAY 16, 2018 2:16 PM PLLD SHUTDOWN ALARM MAY 16, 2018 2:16 PM PLLD SHUTDOWN ALARM MAY 16, 2018 2:15 PM PLLD SHUTDOWN ALARM MAY 16, 2018 2:14 PM PLLD SHUTDOWN ALARM MAY 16, 2018 2:01 PM PLLD SHUTDOWN ALARM MAY 16, 2018 2:00 PM PLLD SHUTDOWN ALARM MAY 16, 2018 2:00 PM PLLD SHUTDOWN ALARM MAY 16, 2018 1:59 PM PLLD SHUTDOWN ALARM Q 3:PREMIUM MAY 16, 2018 3:01 PM PLLD SHUTDOWN ALARM MAY 16, 2018 3:01 PM GROSS LINE FAIL MAY 16, 2018 2:23 PM PLLD SHUTDOWN ALARM MAY 16, 2018 2:23 PM PLLD SHUTDOWN ALARM MAY 16, 2018 2:22 PM PLLD SHUTDOWN ALARM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] MAY 16, 2018 2:01 PM PLLD SHUTDOWN ALARM MAY 16, 2018 2:00 PM PLLD SHUTDOWN ALARM MAY 16, 2018 2:00 PM PLLD SHUTDOWN ALARM MAY 16, 2018 1:59 PM PLLD SHUTDOWN ALARM MAY 16, 2018 1:59 PM PLLD SHUTDOWN ALARM ============================Request: 121 - I30200 - Liquid Sensor Alarm historyRequest Source: Alarm History Request - Line: 7 _________________________ I30200MAY 16, 2018 4:17 PM 279395 COSTCO 6434900 PANAMA LANE BAKERSFIELD, CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNLEADED 87A ANNULAR MAY 16, 2018 1:18 PM HIGH LIQUID ALARM MAY 16, 2018 1:16 PM LOW LIQUID ALARM JUN 7, 2013 11:05 AM SETUP DATA WARNING 2 UNLEADED 87B ANNULAR MAY 16, 2018 1:19 PM HIGH LIQUID ALARM MAY 16, 2018 1:19 PM LOW LIQUID ALARM JUN 7, 2013 11:05 AM SETUP DATA WARNING 3 PREMIUM ANNULAR MAY 16, 2018 1:20 PM HIGH LIQUID ALARM MAY 16, 2018 1:20 PM LOW LIQUID ALARM JUN 7, 2013 11:05 AM SETUP DATA WARNING 4 ADDITIVE ANNULAR MAY 16, 2018 2:30 PM LOW LIQUID ALARM MAY 16, 2018 2:30 PM HIGH LIQUID ALARM JUN 7, 2013 11:05 AM SETUP DATA WARNING 5 ADDITIVE SUMP MAY 16, 2018 2:45 PM SENSOR OUT ALARM MAY 16, 2018 2:37 PM SENSOR OUT ALARM MAY 16, 2018 2:31 PM FUEL ALARM 6 ADDITIVE VENT BOX MAY 16, 2018 2:33 PM FUEL ALARM MAY 16, 2018 2:33 PM SENSOR OUT ALARM MAY 16, 2018 2:32 PM LOW LIQUID ALARM 9 DISP PAN 1-2 MAY 16, 2018 1:51 PM SENSOR OUT ALARM MAY 16, 2018 1:50 PM FUEL ALARM MAY 16, 2018 1:50 PM SENSOR OUT ALARM 10 DISP PAN 3-4 MAY 16, 2018 1:52 PM FUEL ALARM MAY 16, 2018 1:51 PM SENSOR OUT ALARM MAY 16, 2018 1:51 PM LOW LIQUID ALARM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] 11 DISP PAN 5-6 MAY 16, 2018 1:54 PM FUEL ALARM MAY 16, 2018 1:54 PM SENSOR OUT ALARM MAY 16, 2018 1:54 PM LOW LIQUID ALARM 12 DISP PAN 7-8 MAY 16, 2018 1:53 PM FUEL ALARM MAY 16, 2018 1:53 PM SENSOR OUT ALARM MAY 16, 2018 1:52 PM LOW LIQUID ALARM 13 DISP PAN 9-10 MAY 16, 2018 1:56 PM FUEL ALARM MAY 16, 2018 1:55 PM SENSOR OUT ALARM MAY 16, 2018 1:55 PM LOW LIQUID ALARM 14 DISP PAN 11-12 MAY 16, 2018 1:58 PM FUEL ALARM MAY 16, 2018 1:57 PM SENSOR OUT ALARM MAY 16, 2018 1:57 PM LOW LIQUID ALARM 15 DISP PAN 13-14 MAY 16, 2018 2:01 PM FUEL ALARM MAY 16, 2018 2:00 PM SENSOR OUT ALARM MAY 16, 2018 2:00 PM LOW LIQUID ALARM 16 DISP PAN 15-16 MAY 16, 2018 1:59 PM FUEL ALARM MAY 16, 2018 1:59 PM SENSOR OUT ALARM MAY 16, 2018 1:59 PM LOW LIQUID ALARM 17 UNL 87A STP BRINE MAY 16, 2018 1:27 PM FUEL ALARM JUN 7, 2013 11:05 AM SETUP DATA WARNING 18 UNL 87A FILL MAY 16, 2018 1:26 PM FUEL ALARM MAY 16, 2018 1:26 PM SENSOR OUT ALARM MAY 16, 2018 1:26 PM LOW LIQUID ALARM 19 UNL 87B STP BRINE MAY 16, 2018 1:29 PM FUEL ALARM JUN 7, 2013 11:05 AM SETUP DATA WARNING 21 UNL 87B FILL MAY 16, 2018 1:32 PM SENSOR OUT ALARM MAY 16, 2018 1:32 PM FUEL ALARM MAY 16, 2018 1:31 PM SENSOR OUT ALARM 22 91 STP BRINE MAY 16, 2018 1:35 PM FUEL ALARM JUN 7, 2013 11:05 AM SETUP DATA WARNING 23 91 FILL MAY 16, 2018 1:47 PM LOW LIQUID ALARM MAY 16, 2018 1:45 PM SENSOR OUT ALARM MAY 16, 2018 1:45 PM LOW LIQUID ALARM 24 PERMEATOR JUN 7, 2013 11:05 AM SETUP DATA WARNING ============================Request: 122 - I31600 - Smart Sensor Alarm historyRequest Source: Alarm History Request - Line: 8 _________________________ I31600MAY 16, 2018 4:17 PM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] 279395 COSTCO 6434900 PANAMA LANE BAKERSFIELD, CA SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 87A PRODUCT LINE MAY 16, 2018 2:05 PM NO VACUUM ALARM MAY 16, 2018 2:03 PM HIGH LIQUID ALARM JUN 7, 2013 11:10 AM SETUP DATA WARNING 2 VAPOR LINE MAY 16, 2018 2:05 PM NO VACUUM ALARM MAY 16, 2018 2:03 PM HIGH LIQUID ALARM JUN 7, 2013 11:10 AM SETUP DATA WARNING 3 UNL 87A VENT LINE MAY 16, 2018 2:05 PM NO VACUUM ALARM MAY 16, 2018 2:03 PM HIGH LIQUID ALARM JUN 7, 2013 11:10 AM SETUP DATA WARNING 4 UNL 87B PRODUCT LINE MAY 16, 2018 2:16 PM NO VACUUM ALARM MAY 16, 2018 2:14 PM HIGH LIQUID ALARM JUN 7, 2013 11:10 AM SETUP DATA WARNING 5 UNL 87B SIPHON LINE MAY 16, 2018 2:15 PM NO VACUUM ALARM MAY 16, 2018 2:14 PM HIGH LIQUID ALARM JUN 7, 2013 11:10 AM SETUP DATA WARNING 6 UNL 87B VENT LINE MAY 16, 2018 2:16 PM NO VACUUM ALARM MAY 16, 2018 2:14 PM HIGH LIQUID ALARM JUN 7, 2013 11:10 AM SETUP DATA WARNING 7 PRESSURE SENSOR 3-4 JUN 7, 2013 11:09 AM COMMUNICATION ALARM 8 ATP 9 PREMIUM PRODUCT LINE MAY 16, 2018 2:23 PM NO VACUUM ALARM MAY 16, 2018 2:22 PM HIGH LIQUID ALARM JUN 7, 2013 11:10 AM SETUP DATA WARNING 10 PREMIUM VENT LINE MAY 16, 2018 2:23 PM NO VACUUM ALARM MAY 16, 2018 2:22 PM HIGH LIQUID ALARM JUN 7, 2013 11:10 AM SETUP DATA WARNING 11 87A STP SUMP MAY 16, 2018 1:28 PM WATER WARNING MAY 16, 2018 1:27 PM INSTALL ALARM 12 ADDITIVE PRODUCT VAC MAY 16, 2018 2:39 PM NO VACUUM ALARM MAY 16, 2018 2:36 PM HIGH LIQUID ALARM MAY 16, 2018 2:35 PM HIGH LIQUID ALARM 13 87B STP SUMP MAY 16, 2018 1:30 PM WATER WARNING MAY 16, 2018 1:29 PM INSTALL ALARM 14 ADDITIVE VENT VAC MAY 16, 2018 2:38 PM NO VACUUM ALARM MAY 16, 2018 2:36 PM HIGH LIQUID ALARM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] JUN 7, 2013 11:10 AM SETUP DATA WARNING 15 PREMIUM STP SUMP MAY 16, 2018 1:35 PM FUEL ALARM MAY 16, 2018 1:35 PM INSTALL ALARM 17 DISP 1-2 JUN 7, 2013 11:09 AM COMMUNICATION ALARM 18 DISP 3-4 JUN 7, 2013 11:09 AM COMMUNICATION ALARM 19 DISP 5-6 JUN 7, 2013 11:09 AM COMMUNICATION ALARM 20 DISP 7-8 JUN 7, 2013 11:09 AM COMMUNICATION ALARM 21 DISP 9-10 JUN 7, 2013 11:09 AM COMMUNICATION ALARM 22 DISP 11-12 JUN 7, 2013 11:09 AM COMMUNICATION ALARM 23 DISP 13-14 JUN 7, 2013 11:09 AM COMMUNICATION ALARM 24 DISP 15-16 JUN 7, 2013 11:09 AM COMMUNICATION ALARM ============================Request: 123 - I40200 - Input Alarm HistoryRequest Source: Alarm History Request - Line: 9 _________________________ I40200MAY 16, 2018 4:18 PM ============================Request: 124 - I40300 - Input-Generator Alarm HistoryRequest Source: Alarm History Request - Line: 10 _________________________ I40300MAY 16, 2018 4:18 PM ============================Request: 125 - I34200 - Type A 2 Wire CL Alarm HistoryRequest Source: Alarm History Request - Line: 11 _________________________ I34200MAY 16, 2018 4:18 PM ============================Request: 126 - I34700 - Type B 3 Wire CL Alarm HistoryRequest Source: Alarm History Request - Line: 12 _________________________ file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] I34700MAY 16, 2018 4:18 PM ============================Request: 127 - IV0100 - ISD Alarm Status Request Source: Alarm History Request - Line: 13 _________________________ IV0100MAY 16, 2018 4:18 PM 279395 COSTCO 6434900 PANAMA LANE BAKERSFIELD, CA ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSISTISD TYPE: 01.05VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMSDATE TIME DESCRIPTION READING VALUE18-05-13 05:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.5818-05-12 05:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.1718-05-12 05:01:09 A/L RATIO DEGRADATION FP 4 BLEND2 0.7918-05-11 05:01:09 A/L RATIO DEGRADATION FP 4 BLEND2 0.8018-05-10 05:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.5418-05-01 05:01:09 A/L RATIO DEGRADATION FP10 BLEND2 0.7118-04-30 05:01:42 A/L RATIO DEGRADATION FP10 BLEND2 0.7418-04-29 05:01:27 A/L RATIO DEGRADATION FP10 BLEND2 0.8018-04-25 05:01:12 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 10.1218-04-24 05:01:17 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 10.66 FAILURE ALARMSDATE TIME DESCRIPTION READING VALUE17-01-06 05:01:13 A/L RATIO DEGRADATION FP 2 BLEND2 0.7816-04-20 05:01:48 A/L RATIO GROSS BLOCKAGE FP 7 BLEND2 BLKD10-01-14 05:01:09 A/L RATIO GROSS BLOCKAGE FP15 BLEND2 BLKD SHUTDOWN & MISCELLANEOUS EVENTSDATE TIME DESCRIPTION ACTION/NAME18-05-16 13:04:00 TIME CHANGE DETECTED AT: 18-05-16 13:01:3818-05-16 13:01:31 TIME CHANGE DETECTED AT: 13-06-07 13:01:3018-05-16 08:28:26 READINESS ISD:PP EVR:NN EVR READINESS PENDING18-05-16 08:28:26 ISD STARTUP 18-05-16 08:28:21 ISD SHUTDOWN 18-05-01 12:50:16 COLLECTION TEST HH10 GRADE TEST MANUALLY CLEARED file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23643%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:50 PM] 18-04-25 09:20:22 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED 18-04-06 10:35:00 TIME CHANGE DETECTED AT: 18-04-06 11:35:1718-03-11 06:50:38 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 18-03-11 04:00:00 TIME CHANGE DETECTED AT: 18-03-11 03:00:13 End of Report: 180516 +============================================================================| Monitoring System Report Saved at: Wednesday, May 16, 2018 - 4:28:58 PM| (Report Saved Date/Time from PC Clock)| Using Monitoring System Report Utility || Version: Version 6.0.0.100 |+============================================================================