Loading...
HomeMy WebLinkAboutAlarm History 2018file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] +=============================================================+| Monitoring System Report using Report Utility || Version: Version 6.0.0.100 |+=============================================================+ Connected on PC Port: COM4 Settings: 9600 Odd 7, 1 Connect Time/Date from PC Clock: Tuesday, May 15, 2018 - 11:55:05 AM Connect Date from Monitoring System: 180515Connect Time from Monitoring System Clock: 11:55 Site Label: 207901 Costco 6883800 Rosedale HighwaBakersfield, CA ============================Request: 1 - 200 - Site LocationRequest Source: Monitor System Configuration Requests - Line: 1 _________________________ 200207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA 05-15-18 11:55 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 Unleaded 11455 66.38 0.0 73.1 8496 2 Unleaded 11367 65.98 0.0 73.0 8584 3 Premium 9370 56.32 0.0 71.3 10445 4 Additive 1035 37.84 79.3 165 5 Diesel 8203 62.56 0.0 74.4 6784 ============================Request: 2 - I90500 - System Revision LevelRequest Source: Monitor System Configuration Requests - Line: 2 _________________________ I90500 05-15-18 11:55 AMSOFTWARE REVISION LEVELVERSION 333.04SOFTWARE# 346333-100-E CREATED - 13.06.07.08.25 S-MODULE# 330160-164-aSYSTEM FEATURES: file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS BIR ISD/APMPLLD 0.10 AUTO 0.20 REPETITIVWPLLD 0.10 AUTO 0.20 REPETITIV ============================Request: 3 - I50500 - System Type & languageRequest Source: Monitor System Configuration Requests - Line: 3 _________________________ I50500 05-15-18 11:55 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S.SYSTEM LANGUAGE ENGLISHSYSTEM DATE/TIME FORMATMM-DD-YY HH:MM:SS xM ============================Request: 4 - I50201 - Shift Start Time 1Request Source: Monitor System Configuration Requests - Line: 4 _________________________ I50201 05-15-18 11:55 AM SHIFT TIME 1 : DISABLED ============================Request: 5 - I50202 - Shift Start Time 2Request Source: Monitor System Configuration Requests - Line: 5 _________________________ I50202 05-15-18 11:55 AM SHIFT TIME 2 : DISABLED ============================Request: 6 - I50203 - Shift Start Time 3 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] Request Source: Monitor System Configuration Requests - Line: 6 _________________________ I50203 05-15-18 11:55 AM SHIFT TIME 3 : DISABLED ============================Request: 7 - I50204 - Shift Start Time 4Request Source: Monitor System Configuration Requests - Line: 7 _________________________ I50204 05-15-18 11:55 AM SHIFT TIME 4 : DISABLED ============================Request: 8 - I54600 - Tank Periodic Test Needed WarningRequest Source: Monitor System Configuration Requests - Line: 8 _________________________ I54600 05-15-18 11:55 AM TANK PER TST NEEDED WRN: DISABLED ============================Request: 9 - I54900 - Tank Annual Test Needed WarningRequest Source: Monitor System Configuration Requests - Line: 9 _________________________ I54900 05-15-18 11:55 AM TANK ANN TST NEEDED WRN: DISABLED ============================Request: 10 - I55300 - Line Re-Enable MethodRequest Source: Monitor System Configuration Requests - Line: 10 _________________________ I55300 05-15-18 11:55 AM LINE RE-ENABLE METHODPASS LINE TEST file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] ============================Request: 11 - I55600 - Line periodic Test Needed WarningRequest Source: Monitor System Configuration Requests - Line: 11 _________________________ I55600 05-15-18 11:55 AM LINE PER TST NEEDED WRN: DISABLED ============================Request: 12 - I55900 - Line Annual Test Needed WarningRequest Source: Monitor System Configuration Requests - Line: 12 _________________________ I55900 05-15-18 11:55 AM LINE ANN TST NEEDED WRN: DISABLED ============================Request: 13 - I50D00 - Print Temperature CompensationRequest Source: Monitor System Configuration Requests - Line: 13 _________________________ I50D00 05-15-18 11:55 AM PRINT TC VOLUMESENABLED ============================Request: 14 - I50E00 - Temperature Compensation ValueRequest Source: Monitor System Configuration Requests - Line: 14 _________________________ I50E00 05-15-18 11:55 AM TEMP COMPENSATIONVALUE (DEG F ): 60.0 ============================Request: 15 - I60B00 - Tank Stick Height Function EnableRequest Source: Monitor System Configuration Requests - Line: 15 _________________________ file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] I60B00 05-15-18 11:55 AM STICK HEIGHT OFFSET ENABLE STATUSDISABLED ============================Request: 16 - I51400 - H-Protocol Height-Volume FormatRequest Source: Monitor System Configuration Requests - Line: 16 _________________________ I51400 05-15-18 11:55 AM H-PROTOCOL DATA FORMATHEIGHT ============================Request: 17 - I51A01 - Auto Daylight Saving TimeRequest Source: Monitor System Configuration Requests - Line: 17 _________________________ I51A01 05-15-18 11:55 AM DAYLIGHT SAVING TIMEENABLED ON ============================Request: 18 - I51B00 - Start-End Daylight Saving TimeRequest Source: Monitor System Configuration Requests - Line: 18 _________________________ I51B00 05-15-18 11:55 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM ============================Request: 19 - I51600 - Re-Direct Local PrintoutRequest Source: Monitor System Configuration Requests - Line: 19 _________________________ I51600 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] 05-15-18 11:55 AM RE-DIRECT LOCAL PRINTOUTDISABLED ============================Request: 20 - I50400 - RS-232 Security CodeRequest Source: Monitor System Configuration Requests - Line: 20 _________________________ I50400 05-15-18 11:55 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED ============================Request: 21 - I21900 - Tank Chart SecurityRequest Source: Monitor System Configuration Requests - Line: 21 _________________________ I21900 05-15-18 11:55 AM TANK CHART SECURITYDISABLED ============================Request: 22 - I5BD00 - Custom AlarmsRequest Source: Monitor System Configuration Requests - Line: 22 _________________________ I5BD00 05-15-18 11:55 AM CUSTOM ALARM LABELS DISABLED ============================ file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] Request: 23 - I56000 - Mass Density Enable-DisableRequest Source: Monitor System Configuration Requests - Line: 23 _________________________ I56000 05-15-18 11:55 AM MASS/DENSITY DISABLED ============================Request: 24 - I88101 - Comm Port 1 SettingsRequest Source: Monitor System Configuration Requests - Line: 24 _________________________ I88101 05-15-18 11:55 AMPORT SETTINGS: COMM BOARD : 1 (EDIM )RS-232 SECURITYCODE : DISABLED ============================Request: 25 - I88102 - Comm Port 2 SettingsRequest Source: Monitor System Configuration Requests - Line: 25 _________________________ I88102 05-15-18 11:55 AMPORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATARS-232 SECURITYCODE : DISABLED ============================Request: 26 - I88103 - Comm Port 3 SettingsRequest Source: Monitor System Configuration Requests - Line: 26 _________________________ I88103 05-15-18 11:55 AMPORT SETTINGS: file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] COMM BOARD : 3 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATARS-232 SECURITYCODE : DISABLED DTR NORMAL STATE: HIGH ============================Request: 27 - I88104 - Comm Port 4 SettingsRequest Source: Monitor System Configuration Requests - Line: 27 _________________________ I88104 05-15-18 11:55 AM ============================Request: 28 - I88105 - Comm Port 5 SettingsRequest Source: Monitor System Configuration Requests - Line: 28 _________________________ I88105 05-15-18 11:55 AM ============================Request: 29 - I88106 - Comm Port 6 SettingsRequest Source: Monitor System Configuration Requests - Line: 29 _________________________ I88106 05-15-18 11:55 AM ============================Request: 30 - I52000 - Receiver Auto Dial Type and Start TimeRequest Source: Monitor System Configuration Requests - Line: 30 _________________________ I52000 05-15-18 11:55 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE AUG 29, 2013 DISABLED 2 ON DATE AUG 29, 2013 DISABLED 3 ON DATE AUG 29, 2013 DISABLED 4 ON DATE AUG 29, 2013 DISABLED 5 ON DATE AUG 29, 2013 DISABLED file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] 6 ON DATE AUG 29, 2013 DISABLED 7 ON DATE AUG 29, 2013 DISABLED 8 VEEDER ROOT (FMS) ON DATE MAY 9, 2018 9:56 AM ============================Request: 31 - I60100 - Tank ConfigurationRequest Source: Monitor System Configuration Requests - Line: 31 _________________________ I60100 05-15-18 11:56 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 Unleaded ON 2 Unleaded ON 3 Premium ON 4 Additive ON 5 Diesel ON 6 Diesel Add OFF 7 OFF 8 OFF ============================Request: 32 - I60200 - Tank Product LabelRequest Source: Monitor System Configuration Requests - Line: 32 _________________________ I60200 05-15-18 11:56 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 Unleaded 2 Unleaded 3 Premium 4 Additive 5 Diesel 6 Diesel Add 7 8 ============================Request: 33 - I60300 - Tank Product CodeRequest Source: Monitor System Configuration Requests - Line: 33 _________________________ I60300 05-15-18 11:56 AM TANK PRODUCT CODE file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] TANK PRODUCT LABEL 1 Unleaded 1 2 Unleaded 1 3 Premium 2 4 Additive 3 5 Diesel 4 6 Diesel Add 5 7 7 8 8 ============================Request: 34 - I60900 - Tank Thermal Expansion Coefficient Request Source: Monitor System Configuration Requests - Line: 34 _________________________ I60900 05-15-18 11:56 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 Unleaded 0.000700 2 Unleaded 0.000700 3 Premium 0.000700 4 Additive 0.000405 5 Diesel 0.000450 6 Diesel Add 0.000405 7 0.000000 8 0.000000 ============================Request: 35 - I60700 - Tank DiameterRequest Source: Monitor System Configuration Requests - Line: 35 _________________________ I60700 05-15-18 11:56 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 Unleaded 119.63 2 Unleaded 119.63 3 Premium 119.62 4 Additive 47.00 5 Diesel 117.23 6 Diesel Add 0.00 7 0.00 8 0.00 ============================Request: 36 - I60A00 - Tank Full VolumeRequest Source: Monitor System Configuration Requests - Line: 36 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] _________________________ I60A00 05-15-18 11:56 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 Unleaded 20 PTS 19951 2 Unleaded 20 PTS 19951 3 Premium 20 PTS 19815 4 Additive 1 PT 1200 5 Diesel 20 PTS 15067 6 Diesel Add 1 PT 0 7 1 PT 0 8 1 PT 0 ============================Request: 37 - I60400 - Tank 1 Point Full Volume HeightRequest Source: Monitor System Configuration Requests - Line: 37 _________________________ I60400 05-15-18 11:56 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 Unleaded 19951 2 Unleaded 19951 3 Premium 19815 4 Additive 1200 5 Diesel 15067 6 Diesel Add 0 7 0 8 0 ============================Request: 38 - I60500 - Tank 4 Point Full, 3/4, 1/2. 1/4 VolumesRequest Source: Monitor System Configuration Requests - Line: 38 _________________________ I60500 05-15-18 11:56 AM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 Unleaded 19951 16239 10017 3781 2 Unleaded 19951 16239 10017 3781 3 Premium 19815 16281 10132 3912 4 Additive 1200 0 0 0 5 Diesel 15067 12325 7632 2907 6 Diesel Add 0 0 0 0 7 0 0 0 0 8 0 0 0 0 ============================Request: 39 - I60600 - Tank 20 Point Full, 95%, 90%, ...volumesRequest Source: Monitor System Configuration Requests - Line: 39 _________________________ I60600 05-15-18 11:56 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 Unleaded 19951 19639 19029 18233 17292 16239 15096 13885 12623 11328 10017 8705 7408 6144 4929 3781 2722 1774 982 355 2 Unleaded 19951 19639 19029 18233 17292 16239 15096 13885 12623 11328 10017 8705 7408 6144 4929 3781 2722 1774 982 355 3 Premium 19815 19570 18997 18228 17313 16281 15157 13963 12716 11433 10132 8828 7537 6276 5062 3912 2846 1887 1063 415 4 Additive 1200 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5 Diesel 15067 14856 14410 13818 13115 12325 11466 10553 9601 8623 7632 6639 5657 4699 3778 2907 2102 1380 764 235 6 Diesel Add 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7 0 0 0 0 0 0 0 0 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] 0 0 0 0 0 0 0 0 0 0 0 0 8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ============================Request: 40 - I61500 - BIR Meter Data PresentRequest Source: Monitor System Configuration Requests - Line: 40 _________________________ I61500 05-15-18 11:56 AM TANK PRODUCT LABEL METER DATA 1 Unleaded YES 2 Unleaded YES 3 Premium YES 4 Additive NO 5 Diesel YES 6 Diesel Add NO 7 NO 8 NO ============================Request: 41 - I62F00 - Mag Probe Float SizeRequest Source: Monitor System Configuration Requests - Line: 41 _________________________ I62F00 05-15-18 11:56 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 Unleaded 4.0 IN. 2 Unleaded 4.0 IN. 3 Premium 4.0 IN. 4 Additive 4.0 IN. 5 Diesel 2.0 IN. ============================Request: 42 - I62700 - Tank Height Water warning limitRequest Source: Monitor System Configuration Requests - Line: 42 _________________________ I62700 05-15-18 11:56 AM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 Unleaded 1.0 2 Unleaded 1.0 3 Premium 1.0 5 Diesel 0.8 ============================Request: 43 - I64200 - Tank Water Filter LimitRequest Source: Monitor System Configuration Requests - Line: 43 _________________________ I64200 05-15-18 11:56 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 Unleaded LOW 2 Unleaded LOW 3 Premium LOW 5 Diesel LOW ============================Request: 44 - I62400 - Tank High Water Level LimitRequest Source: Monitor System Configuration Requests - Line: 44 _________________________ I62400 05-15-18 11:56 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 Unleaded 1.5 2 Unleaded 1.0 3 Premium 1.0 5 Diesel 2.0 ============================Request: 45 - I62800 - Tank Maximum Volume LimitRequest Source: Monitor System Configuration Requests - Line: 45 _________________________ I62800 05-15-18 11:56 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 19951 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] 2 Unleaded 19951 3 Premium 19815 4 Additive 1200 5 Diesel 15067 6 Diesel Add 0 7 0 8 0 ============================Request: 46 - I62300 - Tank Overfill Level limitRequest Source: Monitor System Configuration Requests - Line: 46 _________________________ I62300 05-15-18 11:56 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 17956 2 Unleaded 17956 3 Premium 17834 4 Additive 1081 5 Diesel 13575 6 Diesel Add 0 7 0 8 0 ============================Request: 47 - I62200 - Tank High Level LimitRequest Source: Monitor System Configuration Requests - Line: 47 _________________________ I62200 05-15-18 11:56 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 18953 2 Unleaded 18953 3 Premium 18824 4 Additive 1141 5 Diesel 14329 6 Diesel Add 0 7 0 8 0 ============================Request: 48 - I62900 - Tank Delivery Required limitRequest Source: Monitor System Configuration Requests - Line: 48 _________________________ I62900 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] 05-15-18 11:56 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 4500 2 Unleaded 4500 3 Premium 4500 4 Additive 132 5 Diesel 3000 6 Diesel Add 300 7 0 8 0 ============================Request: 49 - I62100 - Tank Low Level LimitRequest Source: Monitor System Configuration Requests - Line: 49 _________________________ I62100 05-15-18 11:56 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 600 2 Unleaded 600 3 Premium 600 4 Additive 132 5 Diesel 600 6 Diesel Add 0 7 0 8 0 ============================Request: 50 - I62600 - Tank Leak Alarm LimitRequest Source: Monitor System Configuration Requests - Line: 50 _________________________ I62600 05-15-18 11:56 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 8 2 Unleaded 8 3 Premium 8 4 Additive 8 5 Diesel 8 6 Diesel Add 99 7 99 8 99 ============================ file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] Request: 51 - I62500 - Tank Sudden Loss LimitRequest Source: Monitor System Configuration Requests - Line: 51 _________________________ I62500 05-15-18 11:56 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 25 2 Unleaded 25 3 Premium 25 4 Additive 25 5 Diesel 25 6 Diesel Add 99 7 99 8 99 ============================Request: 52 - I60800 - Tank TiltRequest Source: Monitor System Configuration Requests - Line: 52 _________________________ I60800 05-15-18 11:56 AM TANK TILT TANK PRODUCT LABEL INCHES 1 Unleaded 0.00 2 Unleaded 0.00 3 Premium 0.00 4 Additive 0.00 5 Diesel 0.00 6 Diesel Add 0.00 7 0.00 8 0.00 ============================Request: 53 - I60B00 - Tank Stick Height Function EnableRequest Source: Monitor System Configuration Requests - Line: 53 _________________________ I60B00 05-15-18 11:56 AM STICK HEIGHT OFFSET ENABLE STATUSDISABLED ============================Request: 54 - I60C00 - Tank Stick Height offsetRequest Source: Monitor System Configuration Requests - Line: 54 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] _________________________ I60C00 05-15-18 11:56 AM TANK STICK HEIGHT OFFSETTANK PRODUCT LABEL INCHES 1 Unleaded 0.00 2 Unleaded 0.00 3 Premium 0.00 4 Additive 0.00 5 Diesel 0.00 6 Diesel Add 0.00 7 0.00 8 0.00 ============================Request: 55 - I61200 - Tank Siphon Manifold partnersRequest Source: Monitor System Configuration Requests - Line: 55 _________________________ I61200 05-15-18 11:56 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 Unleaded 2 NONE 2 Unleaded 1 NONE 3 Premium NONE NONE 4 Additive NONE NONE 5 Diesel NONE NONE 6 Diesel Add NONE NONE 7 NONE NONE 8 NONE NONE ============================Request: 56 - I63600 - Tank Periodic Leak Test Minimum VolumeRequest Source: Monitor System Configuration Requests - Line: 56 _________________________ I63600 05-15-18 11:56 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 Unleaded 15960 2 Unleaded 15960 3 Premium 15960 4 Additive 12083 5 Diesel 12083 6 Diesel Add 0 7 0 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] 8 0 ============================Request: 57 - I62A00 - Tank Annual Leak Test Minimum VolumeRequest Source: Monitor System Configuration Requests - Line: 57 _________________________ I62A00 05-15-18 11:56 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 Unleaded 15960 2 Unleaded 15960 3 Premium 15960 4 Additive 0 5 Diesel 12083 6 Diesel Add 0 7 0 8 0 ============================Request: 58 - I62C00 - Tank Periodic Test TypeRequest Source: Monitor System Configuration Requests - Line: 58 _________________________ I62C00 05-15-18 11:56 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 Unleaded STANDARD 2 Unleaded STANDARD 3 Premium STANDARD 4 Additive STANDARD 5 Diesel STANDARD 6 Diesel Add STANDARD 7 STANDARD 8 STANDARD ============================Request: 59 - I62D00 - Enable-Disable Tank Test Leak Fail AlarmsRequest Source: Monitor System Configuration Requests - Line: 59 _________________________ I62D00 05-15-18 11:56 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] 1 Unleaded GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 Unleaded GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 Premium GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 Additive GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 5 Diesel GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 6 Diesel Add GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 7 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 8 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED ============================Request: 60 - I63100 - Tank Leak Test AveragingRequest Source: Monitor System Configuration Requests - Line: 60 _________________________ I63100 05-15-18 11:56 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 Unleaded OFF OFF 2 Unleaded OFF OFF 3 Premium OFF OFF 4 Additive OFF OFF 5 Diesel OFF OFF 6 Diesel Add OFF OFF 7 OFF OFF 8 OFF OFF ============================Request: 61 - I63000 - Tank Leak Test notify file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] Request Source: Monitor System Configuration Requests - Line: 61 _________________________ I63000 05-15-18 11:56 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 Unleaded OFF 2 Unleaded OFF 3 Premium OFF 4 Additive OFF 5 Diesel OFF 6 Diesel Add OFF 7 OFF 8 OFF ============================Request: 62 - I63200 - Tank Test Siphon BreakRequest Source: Monitor System Configuration Requests - Line: 62 _________________________ I63200 05-15-18 11:56 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 Unleaded OFF 2 Unleaded OFF 3 Premium OFF 4 Additive OFF 5 Diesel OFF 6 Diesel Add OFF 7 OFF 8 OFF ============================Request: 63 - I61000 - Tank delivery DelayRequest Source: Monitor System Configuration Requests - Line: 63 _________________________ I61000 05-15-18 11:56 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 Unleaded 1 2 Unleaded 1 3 Premium 1 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] 4 Additive 1 5 Diesel 1 6 Diesel Add 1 7 1 8 1 ============================Request: 64 - I63A00 - Tank low Level Threshold for Line Manifold Request Source: Monitor System Configuration Requests - Line: 64 _________________________ I63A00 05-15-18 11:56 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 Unleaded 10.00% 2 Unleaded 10.00% 3 Premium 10.00% 4 Additive 10.00% 5 Diesel 10.00% 6 Diesel Add 10.00% 7 10.00% 8 10.00% ============================Request: 65 - I61100 - Tank Leak Test Type and Start TimeRequest Source: Monitor System Configuration Requests - Line: 65 _________________________ I61100 05-15-18 11:56 AM LEAK TEST METHOD- - - - - - - - - - - -TEST ON DATE : ALL TANKAUG 10, 2012START TIME : DISABLEDTEST RATE :0.20 GAL/HRDURATION : 2 HOURS TST EARLY STOP:DISABLED ============================Request: 66 - I61300 - CSLD Probability of DetectionRequest Source: Monitor System Configuration Requests - Line: 66 _________________________ I61300 05-15-18 11:56 AMCSLD PROBABLITY OF DETECTION file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] ============================Request: 67 - I61400 - CSLD Climate FactorRequest Source: Monitor System Configuration Requests - Line: 67 _________________________ I61400 05-15-18 11:56 AMCSLD CLIMATE FACTOR ============================Request: 68 - I61600 - Accuchart Update SchedulingRequest Source: Monitor System Configuration Requests - Line: 68 _________________________ I61600 05-15-18 11:56 AM TANK PRODUCT LABEL CAL UPDATE 1 Unleaded IMMEDIATE 2 Unleaded IMMEDIATE 3 Premium NEVER 4 Additive NEVER 5 Diesel IMMEDIATE 6 Diesel Add NEVER 7 NEVER 8 NEVER ============================Request: 69 - I61A00 - In-Tank Leak Test Early StopRequest Source: Monitor System Configuration Requests - Line: 69 _________________________ I61A00 05-15-18 11:56 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 Unleaded DISABLED 2 Unleaded DISABLED 3 Premium DISABLED 4 Additive DISABLED 5 Diesel DISABLED 6 Diesel Add DISABLED 7 DISABLED 8 DISABLED ============================ file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] Request: 70 - I61B00 - In-Tank Static Gross Test Auto-ConfirmRequest Source: Monitor System Configuration Requests - Line: 70 _________________________ I61B00 05-15-18 11:56 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM ============================Request: 71 - I61C00 - CSLD Report Only modeRequest Source: Monitor System Configuration Requests - Line: 71 _________________________ I61C00 05-15-18 11:56 AM CSLD REPORT ONLY ============================Request: 72 - I62B00 - Tank Last Annual TestRequest Source: Monitor System Configuration Requests - Line: 72 _________________________ I62B00 05-15-18 11:56 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 Unleaded 00-00-00 2 Unleaded 00-00-00 3 Premium 00-00-00 4 Additive 00-00-00 5 Diesel 00-00-00 6 Diesel Add 00-00-00 7 00-00-00 8 00-00-00 ============================Request: 73 - I63300 - Leak Test Report TypeRequest Source: Monitor System Configuration Requests - Line: 73 _________________________ I63300 05-15-18 11:56 AM LEAK TEST REPORT FORMAT: NORMAL file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] ============================Request: 74 - I63400 - Tank HRM Reconciliation Warning limitRequest Source: Monitor System Configuration Requests - Line: 74 _________________________ I63400 05-15-18 11:56 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 0 2 Unleaded 0 3 Premium 0 4 Additive 0 5 Diesel 0 6 Diesel Add 0 7 0 8 0 ============================Request: 75 - I63500 - Tank HEM Reconciliation AlarmRequest Source: Monitor System Configuration Requests - Line: 75 _________________________ I63500 05-15-18 11:56 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 Unleaded 1 2 Unleaded 1 3 Premium 1 4 Additive 1 5 Diesel 1 6 Diesel Add 1 7 1 8 1 ============================Request: 76 - I63900 - Tank Accuchart End Shape Type and FactorRequest Source: Monitor System Configuration Requests - Line: 76 _________________________ I63900 05-15-18 11:56 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 Unleaded file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] END FACTOR: HEMISPHER 2 Unleaded END FACTOR: HEMISPHER 3 Premium END FACTOR: OTHEREND VALUE: 1.0 4 Additive END FACTOR: OTHEREND VALUE: 0.8 5 Diesel END FACTOR: OTHEREND VALUE: 0.8 6 Diesel Add END FACTOR: NONE 7 END FACTOR: NONE 8 END FACTOR: NONE ============================Request: 77 - I78000 - PLLD SetupRequest Source: Monitor System Configuration Requests - Line: 77 _________________________ I78000 05-15-18 11:56 AM PRESSURE LINE LEAK SETUP Q 1:UNLEADED 87A TYP:1.5/2IN ENVIRN GFLXD1.5IN DIA LEN: 210 FEET 2.xIN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV0.10 GPH TEST: AUTOSHUTDOWN RATE: 3.0 GPHLOW PRESSURE SHUTOFF:YESLOW PRESSURE : 5 PSI T 1:Unleaded DISPENSE MODE: file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] STANDARDSENSOR: HIGH PRESSUREPRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 2:UNLEADED 87B TYP:1.5/2IN ENVIRN GFLXD1.5IN DIA LEN: 210 FEET 2.xIN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV0.10 GPH TEST: AUTOSHUTDOWN RATE: 3.0 GPHLOW PRESSURE SHUTOFF:YESLOW PRESSURE : 5 PSI T 2:Unleaded DISPENSE MODE: STANDARDSENSOR: HIGH PRESSUREPRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 3:PREMIUM TYP:1.5/2IN ENVIRN GFLXD1.5IN DIA LEN: 305 FEET 2.xIN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV0.10 GPH TEST: AUTOSHUTDOWN RATE: 3.0 GPHLOW PRESSURE SHUTOFF:YESLOW PRESSURE : 5 PSI T 3:Premium DISPENSE MODE: STANDARDSENSOR: HIGH PRESSUREPRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO Q 4:DIESEL TYP:2.0/3.0IN FIBERGLASS2.0IN DIA LEN: 150 FEET 3.0IN DIA LEN: 0 FEET 0.20 GPH TEST: REPETITIV0.10 GPH TEST: AUTOSHUTDOWN RATE: 3.0 GPHLOW PRESSURE SHUTOFF:YESLOW PRESSURE : 5 PSI T 5:Diesel DISPENSE MODE: file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] STANDARDSENSOR: NON-VENTEDPRESSURE OFFSET: 0.0PSI MECHANICAL BLENDER: NO ============================Request: 78 - I77700 - PLLD Primary Line DiameterRequest Source: Monitor System Configuration Requests - Line: 78 _________________________ I77700 05-15-18 11:56 AM ============================Request: 79 - I77800 - PLLD Secondary Line DiameterRequest Source: Monitor System Configuration Requests - Line: 79 _________________________ I77800 05-15-18 11:56 AM ============================Request: 80 - I78C00 - PLLD 0.20 GPH Test ScheduleRequest Source: Monitor System Configuration Requests - Line: 80 _________________________ I78C00 05-15-18 11:56 AM PRESSURE LINE LEAK 0.20 TEST SCHEDULE LINE 0.20 GPH TESTQ 1:UNLEADED 87A REPETITIVQ 2:UNLEADED 87B REPETITIVQ 3:PREMIUM REPETITIVQ 4:DIESEL REPETITIVQ 5:DIE DISABLEDQ 6: DISABLED ============================Request: 81 - I78300 - PLLD 0.10 GPH Test ScheduleRequest Source: Monitor System Configuration Requests - Line: 81 _________________________ I78300 05-15-18 11:56 AM PRESSURE LINE LEAK 0.10 TEST SCHEDULE file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] LINE 0.10 GPH TESTQ 1:UNLEADED 87A AUTOQ 2:UNLEADED 87B AUTOQ 3:PREMIUM AUTOQ 4:DIESEL AUTOQ 5:DIE DISABLEDQ 6: DISABLED ============================Request: 82 - I78F00 - PLLD Dispense ThresholdRequest Source: Monitor System Configuration Requests - Line: 82 _________________________ I78F00 05-15-18 11:56 AM PRESSURE LINE LEAK DISPENSE THRESHOLD LINE LOW PRESSUREQ 1:UNLEADED 87A 5 PSIQ 2:UNLEADED 87B 5 PSIQ 3:PREMIUM 5 PSIQ 4:DIESEL 5 PSIQ 5:DIE 0 PSIQ 6: 0 PSI ============================Request: 83 - I78700 - PLLD Disable Alarm AssignmentsRequest Source: Monitor System Configuration Requests - Line: 83 _________________________ I78700 05-15-18 11:56 AM PRESSURE LLD SETUP REPORT Q 1:UNLEADED 87A IN-TANK ALARMS T 1:HIGH WATER ALARM T 1:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 6:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] L15:FUEL ALARM L22:FUEL ALARM L23:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L22:SENSOR OUT ALARM L23:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 6:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L22:SHORT ALARM L23:SHORT ALARM L 1:HIGH LIQUID ALARM L 2:HIGH LIQUID ALARM L 3:HIGH LIQUID ALARM L 6:HIGH LIQUID ALARM L22:HIGH LIQUID ALARM L23:HIGH LIQUID ALARM L 1:LOW LIQUID ALARM L 2:LOW LIQUID ALARM L 3:LOW LIQUID ALARM L 6:LOW LIQUID ALARM L22:LOW LIQUID ALARM L23:LOW LIQUID ALARM L 2:LIQUID WARNING L 3:LIQUID WARNING L 6:LIQUID WARNING L22:LIQUID WARNING L23:LIQUID WARNING PRESSURE LINE LEAK ALL:PLLD OPEN ALARM ALL:CONT HANDLE ALM ALL:LN EQUIP FAULT ALM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] ISD SENSOR OUT FAIL PC-ISD FAILURE ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL Q 2:UNLEADED 87B IN-TANK ALARMS T 2:HIGH WATER ALARM T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 3:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L22:FUEL ALARM L23:FUEL ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L22:SENSOR OUT ALARM L23:SENSOR OUT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L22:SHORT ALARM L23:SHORT ALARM L 3:HIGH LIQUID ALARM L 4:HIGH LIQUID ALARM L 5:HIGH LIQUID ALARM L 6:HIGH LIQUID ALARM L22:HIGH LIQUID ALARM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] L23:HIGH LIQUID ALARM L 3:LOW LIQUID ALARM L 4:LOW LIQUID ALARM L 5:LOW LIQUID ALARM L 6:LOW LIQUID ALARM L22:LOW LIQUID ALARM L23:LOW LIQUID ALARM L 3:LIQUID WARNING L 5:LIQUID WARNING L 6:LIQUID WARNING L22:LIQUID WARNING L23:LIQUID WARNING PRESSURE LINE LEAK ALL:PLLD OPEN ALARM ALL:CONT HANDLE ALM ALL:LN EQUIP FAULT ALM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL PC-ISD FAILURE ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL Q 3:PREMIUM IN-TANK ALARMS T 3:HIGH WATER ALARM T 3:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L22:FUEL ALARM L23:FUEL ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L22:SENSOR OUT ALARM L23:SENSOR OUT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L22:SHORT ALARM L23:SHORT ALARM L 7:HIGH LIQUID ALARM L 8:HIGH LIQUID ALARM L 9:HIGH LIQUID ALARM L22:HIGH LIQUID ALARM L23:HIGH LIQUID ALARM L 7:LOW LIQUID ALARM L 8:LOW LIQUID ALARM L 9:LOW LIQUID ALARM L22:LOW LIQUID ALARM L23:LOW LIQUID ALARM L 8:LIQUID WARNING L 9:LIQUID WARNING L22:LIQUID WARNING L23:LIQUID WARNING PRESSURE LINE LEAK ALL:PLLD OPEN ALARM ALL:CONT HANDLE ALM ALL:LN EQUIP FAULT ALM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL PC-ISD FAILURE ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL Q 4:DIESEL IN-TANK ALARMS T 5:HIGH WATER ALARM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] T 5:LOW PRODUCT ALARM LIQUID SENSOR ALMS L21:FUEL ALARM L22:FUEL ALARM L23:FUEL ALARM L24:FUEL ALARM L25:FUEL ALARM L26:FUEL ALARM L21:SENSOR OUT ALARM L22:SENSOR OUT ALARM L23:SENSOR OUT ALARM L24:SENSOR OUT ALARM L25:SENSOR OUT ALARM L26:SENSOR OUT ALARM L21:SHORT ALARM L22:SHORT ALARM L23:SHORT ALARM L24:SHORT ALARM L25:SHORT ALARM L26:SHORT ALARM L21:HIGH LIQUID ALARM L22:HIGH LIQUID ALARM L23:HIGH LIQUID ALARM L25:HIGH LIQUID ALARM L26:HIGH LIQUID ALARM L21:LOW LIQUID ALARM L22:LOW LIQUID ALARM L23:LOW LIQUID ALARM L24:LOW LIQUID ALARM L25:LOW LIQUID ALARM L26:LOW LIQUID ALARM L21:LIQUID WARNING L22:LIQUID WARNING L23:LIQUID WARNING L24:LIQUID WARNING L25:LIQUID WARNING L26:LIQUID WARNING PRESSURE LINE LEAK ALL:PLLD OPEN ALARM ALL:CONT HANDLE ALM ALL:LN EQUIP FAULT ALM SMARTSENSOR ALARMS s 3:HIGH LIQUID WARNING s 4:HIGH LIQUID WARNING s 3:HIGH LIQUID ALARM s 4:HIGH LIQUID ALARM s 3:SENSOR FAULT WARN s 4:SENSOR FAULT WARN s 3:VACUUM WARNING s 3:NO VACUUM ALARM s 4:NO VACUUM ALARM Q 5:DIE file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] - NO ALARM ASSIGNMENTS - Q 6: - NO ALARM ASSIGNMENTS - ============================Request: 84 - I70200 - Liquid Sensor Location LabelRequest Source: Monitor System Configuration Requests - Line: 84 _________________________ I70200 05-15-18 11:57 AM LIQUID LABEL DEVICE LABEL 1 UNLEADED 87A ANNULAR 2 UNLEADED 87A FILL 3 UNLEADED 87A STP 4 UNLEADED 87B ANNULAR 5 UNLEADED 87B FILL 6 UNLEADED 87B STP 7 PREMIUM ANNULAR 8 PREMIUM FILL 9 PREMIUM STP 10 DISPENSER PAN 1-2 11 DISPENSER PAN 3-4 12 DISPENSER PAN 5-6 13 DISPENSER PAN 7-8 14 DISPENSER PAN 9-10 15 DISPENSER PAN 11-12 16 ADDITIVE ANNULAR 17 ADDITIVE VENT BOX 18 19 20 21 DIESEL ANNULAR 22 DISPENSER PAN 13-14 23 DISPENSER PAN 15-16 24 DIESEL FILL 25 DIESEL STP 26 DIESEL VENT 27 28 ============================Request: 85 - I70300 - Liquid Sensor TypeRequest Source: Monitor System Configuration Requests - Line: 85 _________________________ I70300 05-15-18 11:57 AM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] LIQUID TYPE SENSOR LOCATION TYPE 1 UNLEADED 87A ANNULAR DUAL POINT HYDROSTATIC 2 UNLEADED 87A FILL DUAL FLT. DISCRIMINATING 3 UNLEADED 87A STP TRI-STATE (SINGLE FLOAT) 4 UNLEADED 87B ANNULAR DUAL POINT HYDROSTATIC 5 UNLEADED 87B FILL DUAL FLT. DISCRIMINATING 6 UNLEADED 87B STP DUAL FLT. DISCRIMINATING 7 PREMIUM ANNULAR DUAL POINT HYDROSTATIC 8 PREMIUM FILL DUAL FLT. DISCRIMINATING 9 PREMIUM STP DUAL FLT. DISCRIMINATING 10 DISPENSER PAN 1-2 TRI-STATE (SINGLE FLOAT) 11 DISPENSER PAN 3-4 TRI-STATE (SINGLE FLOAT) 12 DISPENSER PAN 5-6 TRI-STATE (SINGLE FLOAT) 13 DISPENSER PAN 7-8 TRI-STATE (SINGLE FLOAT) 14 DISPENSER PAN 9-10 TRI-STATE (SINGLE FLOAT) 15 DISPENSER PAN 11-12 TRI-STATE (SINGLE FLOAT) 16 ADDITIVE ANNULAR TRI-STATE (SINGLE FLOAT) 17 ADDITIVE VENT BOX TRI-STATE (SINGLE FLOAT) 18 TRI-STATE (SINGLE FLOAT) 19 TRI-STATE (SINGLE FLOAT) 20 TRI-STATE (SINGLE FLOAT) 21 DIESEL ANNULAR DUAL POINT HYDROSTATIC 22 DISPENSER PAN 13-14 DW SUMP 2-1 23 DISPENSER PAN 15-16 DW SUMP 2-1 24 DIESEL FILL DW SUMP 2-1 25 DIESEL STP DW SUMP 2-1 26 DIESEL VENT DW SUMP 2-1 27 TRI-STATE (SINGLE FLOAT) 28 TRI-STATE (SINGLE FLOAT) ============================Request: 86 - I70400 - Liquid Sensor CategoryRequest Source: Monitor System Configuration Requests - Line: 86 _________________________ I70400 05-15-18 11:57 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNLEADED 87A ANNULAR ANNULAR SPACE 2 UNLEADED 87A FILL PIPING SUMP 3 UNLEADED 87A STP STP SUMP 4 UNLEADED 87B ANNULAR ANNULAR SPACE 5 UNLEADED 87B FILL PIPING SUMP 6 UNLEADED 87B STP STP SUMP 7 PREMIUM ANNULAR ANNULAR SPACE 8 PREMIUM FILL PIPING SUMP 9 PREMIUM STP STP SUMP 10 DISPENSER PAN 1-2 DISPENSER PAN 11 DISPENSER PAN 3-4 DISPENSER PAN file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] 12 DISPENSER PAN 5-6 DISPENSER PAN 13 DISPENSER PAN 7-8 DISPENSER PAN 14 DISPENSER PAN 9-10 DISPENSER PAN 15 DISPENSER PAN 11-12 DISPENSER PAN 16 ADDITIVE ANNULAR ANNULAR SPACE 17 ADDITIVE VENT BOX DISPENSER PAN 18 OTHER SENSORS 19 OTHER SENSORS 20 OTHER SENSORS 21 DIESEL ANNULAR ANNULAR SPACE 22 DISPENSER PAN 13-14 DISPENSER PAN 23 DISPENSER PAN 15-16 DISPENSER PAN 24 DIESEL FILL OTHER SENSORS 25 DIESEL STP STP SUMP 26 DIESEL VENT DISPENSER PAN 27 OTHER SENSORS 28 OTHER SENSORS ============================Request: 87 - I74200 - Type "A" 2 Wire Sensor Location LabelRequest Source: Monitor System Configuration Requests - Line: 87 _________________________ I74200 05-15-18 11:58 AM ============================Request: 88 - I74300 - Type "A" 2 Wire Sensor TypeRequest Source: Monitor System Configuration Requests - Line: 88 _________________________ I74300 05-15-18 11:58 AM ============================Request: 89 - I74400 - Type "A" 2 Wire Sensor CategoryRequest Source: Monitor System Configuration Requests - Line: 89 _________________________ I74400 05-15-18 11:58 AM ============================Request: 90 - I74700 - Type "B" 3 Wire Sensor Location LabelRequest Source: Monitor System Configuration Requests - Line: 90 _________________________ I74700 05-15-18 11:58 AM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] ============================Request: 91 - I74800 - Type "B" 3 Wire Sensor TypeRequest Source: Monitor System Configuration Requests - Line: 91 _________________________ I74800 05-15-18 11:58 AM ============================Request: 92 - I74900 - Type "B" Sensor CategoryRequest Source: Monitor System Configuration Requests - Line: 92 _________________________ I74900 05-15-18 11:58 AM ============================Request: 93 - I7BC00 - I/O Device Line Disable AssignmentsRequest Source: Monitor System Configuration Requests - Line: 93 _________________________ I7BC00 05-15-18 11:58 AM ============================Request: 94 - I80200 - I/O Input location LabelRequest Source: Monitor System Configuration Requests - Line: 94 _________________________ I80200 05-15-18 11:58 AM ============================Request: 95 - I80300 - I/O Input TypeRequest Source: Monitor System Configuration Requests - Line: 95 _________________________ I80300 05-15-18 11:58 AM ============================Request: 96 - I80400 - I/O Input Dispense modeRequest Source: Monitor System Configuration Requests - Line: 96 _________________________ file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] I80400 05-15-18 11:58 AM ============================Request: 97 - I80700 - I/O Relay location labelRequest Source: Monitor System Configuration Requests - Line: 97 _________________________ I80700 05-15-18 11:58 AM RELAY LABEL DEVICE LABEL 1 DATA HUT V-R ALARM 2 MEMBERSHIP V-R ALARM 3 ADDITIVE SHUTDOWN 4 ============================Request: 98 - I80900 - I/O Relay OrientationRequest Source: Monitor System Configuration Requests - Line: 98 _________________________ I80900 05-15-18 11:58 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 DATA HUT V-R ALARM NORMALLY OPEN 2 MEMBERSHIP V-R ALARM NORMALLY OPEN 3 ADDITIVE SHUTDOWN NORMALLY CLOSED 4 NORMALLY OPEN ============================Request: 99 - I80B00 - I/O Relay Tank AssignmentRequest Source: Monitor System Configuration Requests - Line: 99 _________________________ I80B00 05-15-18 11:58 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 DATA HUT V-R ALARM NONE 2 MEMBERSHIP V-R ALARM NONE 3 ADDITIVE SHUTDOWN 4 4 NONE file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] ============================Request: 100 - I80A00 - I/O Relay TypeRequest Source: Monitor System Configuration Requests - Line: 100 _________________________ I80A00 05-15-18 11:58 AM RELAY TYPE RELAY DESIGNATION TYPE 1 DATA HUT V-R ALARM STANDARD 2 MEMBERSHIP V-R ALARM STANDARD 3 ADDITIVE SHUTDOWN STANDARD 4 STANDARD ============================Request: 101 - I80C00 - I/O External input TypeRequest Source: Monitor System Configuration Requests - Line: 101 _________________________ I80C00 05-15-18 11:58 AM ============================Request: 102 - I80800 - I/O Relay Alarm AssignmentsRequest Source: Monitor System Configuration Requests - Line: 102 _________________________ I80800 05-15-18 11:58 AM RELAY SETUP REPORT R 1:DATA HUT V-R ALARM TYPE: STANDARDNORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:LEAK ALARM ALL:HIGH WATER ALARM ALL:OVERFILL ALARM ALL:LOW PRODUCT ALARM ALL:SUDDEN LOSS ALARM ALL:HIGH PRODUCT ALARM ALL:INVALID FUEL LEVEL file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED ALL:MAX PRODUCT ALARM ALL:LOW TEMP WARNING ALL:FUEL QUALITY ALARM LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM ALL:HIGH LIQUID ALARM ALL:LOW LIQUID ALARM ALL:LIQUID WARNING PRESSURE LINE LEAK ALL:GROSS LINE FAIL ALL:ANNUAL LINE FAIL ALL:PER TST NEEDED WRN ALL:PER TST NEEDED ALM ALL:PLLD OPEN ALARM ALL:PLLD SHUTDOWN ALARM ALL:PERIODIC LINE FAIL ALL:ANN TST NEEDED WRN ALL:ANN TST NEEDED ALM ALL:LOW PRESSURE ALARM ALL:CONT HANDLE ALM ALL:FUEL OUT ALL:LN EQUIP FAULT ALM ALL:GRS TST NEEDED ALM ISD SITE ALARMS ISD STAGE I WARN ISD GROSS PRES FAIL ISD DEGRD PRES WARN ISD DEGRD PRES FAIL ISD VAPOR LEAK WARN ISD VAPOR LEAK FAIL ISD VP PRES WARN ISD VP PRES FAIL ISD VP STATUS FAIL MISSING RELAY SETUP MISSING HOSE SETUP MISSING TANK SETUP MISS VAPOR FLOW MTR MISS VAPOR PRES SEN MISSING VP INPUT ISD SETUP WARN ISD SETUP FAIL ISD SENSOR OUT WARN ISD SENSOR OUT FAIL PC-ISD FAILURE PMC ALARMS VP RUNTIME FAULT VP EMISSIONS WARN VP EMISSIONS FAIL file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] VP PRESSURE WARN VP PRESSURE FAIL VP DUTY CYCLE WARN VP DUTY CYCLE FAIL PMC SETUP FAIL PMC SENSOR FAULT R 2:MEMBERSHIP V-R ALARMTYPE: STANDARDNORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:LEAK ALARM ALL:HIGH WATER ALARM ALL:OVERFILL ALARM ALL:LOW PRODUCT ALARM ALL:SUDDEN LOSS ALARM ALL:HIGH PRODUCT ALARM ALL:INVALID FUEL LEVEL ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED ALL:MAX PRODUCT ALARM ALL:LOW TEMP WARNING ALL:FUEL QUALITY ALARM LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM ALL:HIGH LIQUID ALARM ALL:LOW LIQUID ALARM ALL:LIQUID WARNING PRESSURE LINE LEAK ALL:GROSS LINE FAIL ALL:ANNUAL LINE FAIL ALL:PER TST NEEDED WRN ALL:PER TST NEEDED ALM ALL:PLLD OPEN ALARM ALL:PLLD SHUTDOWN ALARM ALL:PERIODIC LINE FAIL ALL:ANN TST NEEDED WRN ALL:ANN TST NEEDED ALM ALL:LOW PRESSURE ALARM ALL:CONT HANDLE ALM ALL:FUEL OUT ALL:LN EQUIP FAULT ALM ALL:GRS TST NEEDED ALM ISD SITE ALARMS ISD STAGE I WARN file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] ISD GROSS PRES WARN ISD GROSS PRES FAIL ISD DEGRD PRES WARN ISD DEGRD PRES FAIL ISD VAPOR LEAK WARN ISD VAPOR LEAK FAIL ISD VP PRES WARN ISD VP PRES FAIL ISD VP STATUS WARN ISD VP STATUS FAIL MISSING RELAY SETUP MISSING HOSE SETUP MISSING TANK SETUP MISS VAPOR FLOW MTR MISS VAPOR PRES SEN MISSING VP INPUT ISD SETUP WARN ISD SETUP FAIL ISD SENSOR OUT WARN ISD SENSOR OUT FAIL PMC ALARMS VP RUNTIME FAULT VP EMISSIONS WARN VP EMISSIONS FAIL VP PRESSURE WARN VP PRESSURE FAIL VP DUTY CYCLE WARN VP DUTY CYCLE FAIL PMC SETUP FAIL PMC SENSOR FAULT R 3:ADDITIVE SHUTDOWN TYPE: STANDARDNORMALLY CLOSED TANK #: 4 IN-TANK ALARMS T 4:HIGH WATER ALARM T 4:LOW PRODUCT ALARM LIQUID SENSOR ALMS L16:FUEL ALARM L17:FUEL ALARM L16:SENSOR OUT ALARM L17:SENSOR OUT ALARM L16:SHORT ALARM L17:SHORT ALARM R 4: TYPE: STANDARD file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - ============================Request: 103 - I79000 - DIM Software RevisionRequest Source: Monitor System Configuration Requests - Line: 103 _________________________ I79000 05-15-18 11:58 AM EDIM:1 VR:330273-002-C TD:97.11.13.15.52 ============================Request: 104 - I79100 - Mechanical Dispenser Interface StringRequest Source: Monitor System Configuration Requests - Line: 104 _________________________ I79100 05-15-18 11:58 AM ============================Request: 105 - I72300 - Smart Sensor CategoryRequest Source: Monitor System Configuration Requests - Line: 105 _________________________ I72300 05-15-18 11:58 AM 207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY01 VFM 13-14 AIR FLOW METER02 VFM 15,16 AIR FLOW METER03 DIESEL PRODUCT VAC. VAC SENSOR04 DIESEL VENT VAC. VAC SENSOR05 UNKNOWN06 UNKNOWN07 UNKNOWN08 ATM P ATM P SENSOR09 VFM 1-2 AIR FLOW METER file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] 10 VFM 3-4 AIR FLOW METER11 VFM 5-6 AIR FLOW METER12 VFM 7-8 AIR FLOW METER13 VFM 9-10 AIR FLOW METER14 VFM 11-12 AIR FLOW METER15 UNKNOWN16 PRESURE SENSOR 3-4 VAPOR PRESSURE17 UNKNOWN18 UNKNOWN19 UNKNOWN20 UNKNOWN21 UNKNOWN22 UNKNOWN23 UNKNOWN24 UNKNOWN25 UNKNOWN26 UNKNOWN27 UNKNOWN28 UNKNOWN29 UNKNOWN30 UNKNOWN31 UNKNOWN32 UNKNOWN33 UNKNOWN34 UNKNOWN35 UNKNOWN36 UNKNOWN37 UNKNOWN38 UNKNOWN39 UNKNOWN40 UNKNOWN ============================Request: 106 - IV4E00 - ISD EVR TypeRequest Source: Monitor System Configuration Requests - Line: 106 _________________________ IV4E00 05-15-18 11:58 AM 207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA EVR/ISD SETUPTYPE: VACUUM ASSISTVACUUM ASSIST TYPE: HEALY VAC ============================Request: 107 - IV4F00 - ISD Nozzle TypeRequest Source: Monitor System Configuration Requests - Line: 107 _________________________ file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] IV4F00 05-15-18 11:58 AM 207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA NOZZLE A/L RANGEA/L RATIO: 0.95 - 1.15 ============================Request: 108 - IV4000 - Vapor Processor TypeRequest Source: Monitor System Configuration Requests - Line: 108 _________________________ IV4000 05-15-18 11:58 AM 207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA VAPOR PROCESSOR TYPENONE ============================Request: 109 - IV4700 - ISD Assessment Start and Post DelayRequest Source: Monitor System Configuration Requests - Line: 109 _________________________ IV4700 05-15-18 11:59 AM 207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA ASSESSMENT TIMESTART TIME: 11:59 PMTIME DELAY MINUTES: 1 ============================Request: 110 - IV5200 - High ORVR ConfigurationRequest Source: Monitor System Configuration Requests - Line: 110 _________________________ IV5200 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] 05-15-18 11:59 AM 207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA ACCEPT HIGH ORVR: NO ============================Request: 111 - IV4A00 - ISD Hose TableRequest Source: Monitor System Configuration Requests - Line: 111 _________________________ IV4A00 05-15-18 11:59 AM 207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 UU BLEND2 02 02 02 01 UU BLEND2 03 03 03 02 UU BLEND2 04 04 04 02 UU BLEND2 05 05 05 03 UU BLEND2 06 06 06 03 UU BLEND2 07 07 07 04 UU BLEND2 08 08 08 04 UU BLEND2 09 09 09 05 UU BLEND2 10 10 10 05 UU BLEND2 11 11 11 06 UU BLEND2 12 12 12 06 UU BLEND2 13 13 13 08 UU BLEND2 14 14 14 08 UU BLEND2 15 15 15 07 UU BLEND2 16 16 16 07 UU BLEND2 ============================Request: 112 - IV4B00 - ISD Grade TableRequest Source: Monitor System Configuration Requests - Line: 112 _________________________ IV4B00 05-15-18 11:59 AM 207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H401 01 01/01 02/01 xx/xx xx/xx02 01 01/02 02/02 xx/xx xx/xx03 02 01/03 02/03 xx/xx xx/xx04 02 01/04 02/04 xx/xx xx/xx05 03 01/05 02/05 xx/xx xx/xx06 03 01/06 02/06 xx/xx xx/xx07 04 01/07 02/07 xx/xx xx/xx08 04 01/08 02/08 xx/xx xx/xx09 05 01/09 02/09 xx/xx xx/xx10 05 01/10 02/10 xx/xx xx/xx11 06 01/11 02/11 xx/xx xx/xx12 06 01/12 02/12 xx/xx xx/xx13 08 01/13 02/13 xx/xx xx/xx14 08 01/14 02/14 xx/xx xx/xx15 07 01/15 02/15 xx/xx xx/xx16 07 01/16 02/16 xx/xx xx/xx ============================Request: 113 - IV4900 - ISD Hose Label TableRequest Source: Monitor System Configuration Requests - Line: 113 _________________________ IV4900 05-15-18 11:59 AM 207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA LABEL TABLEID LABEL01 UNASSIGNED02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 ============================Request: 114 - IV1000 - ISD VersionRequest Source: Monitor System Configuration Requests - Line: 114 _________________________ file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] IV1000 05-15-18 11:59 AM ISD VERSION: 01.05 ============================| Next Request Source: || Alarm History Request+==========================+Request: 115 - I10200 - System ConfigurationRequest Source: Alarm History Request - Line: 1 _________________________ I10200 05-15-18 12:00 PM 207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 163623 163563 2 INTERSTITIAL BD 201793 201820 3 INTERSTITIAL BD 201291 201177 4 7SMARTSENSOR BD 511111 511727 5 8SMARTSENSOR BD 39651 39575 6 4 PRB 4 LQD BD 337202 337440 7 PLLD SENSOR BD 3918 3908 8 INTERSTITIAL BD 201428 201475 9 RELAY BOARD 15000 15007 10 PLLD POWER BD 100818 100803 11 PLLD POWER BD 101059 101245 12 UNUSED 4910915 4870024 13 UNUSED 4907968 4869855 14 UNUSED 4906874 4868098 15 UNUSED 4908810 4872628 16 UNUSED 4906327 4867971 COMM 1 ELEC DISP INT. 100994 101046 COMM 2 RS232 SERIAL BD 15000 15007 COMM 3 SERIAL SAT BD 482699 482581 COMM 4 UNUSED 4916219 4871718 COMM 5 UNUSED 4912683 4870321 COMM 6 UNUSED 4913567 4870300 ============================Request: 116 - I90200 - System Revision LevelRequest Source: Alarm History Request - Line: 2 _________________________ I90200 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] 05-15-18 12:00 PMSOFTWARE REVISION LEVELVERSION 333.04SOFTWARE# 346333-100-E CREATED - 13.06.07.08.25 S-MODULE# 330160-164-aSYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS BIR ISD/APMPLLD 0.10 AUTO 0.20 REPETITIVWPLLD 0.10 AUTO 0.20 REPETITIV ============================Request: 117 - I11100 - Priority Alarm HistoryRequest Source: Alarm History Request - Line: 3 _________________________ I11100 05-15-18 12:00 PM 207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA PRIORITY ALARM HISTORYID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIMEQ 4 OTHER DIESEL PLLD SHUTDOWN ALARM CLEAR 05-15-18 11:46 AMQ 4 OTHER DIESEL GROSS LINE FAIL CLEAR 05-15-18 11:46 AMQ 3 OTHER PREMIUM PLLD SHUTDOWN ALARM CLEAR 05-15-18 11:46 AMQ 3 OTHER PREMIUM GROSS LINE FAIL CLEAR 05-15-18 11:46 AMQ 2 OTHER UNLEADED 87B PLLD SHUTDOWN ALARM CLEAR 05-15-18 11:45 AMQ 2 OTHER UNLEADED 87B GROSS LINE FAIL CLEAR 05-15-18 11:45 AMQ 1 OTHER UNLEADED 87A PLLD SHUTDOWN ALARM CLEAR 05-15-18 11:44 AMQ 1 OTHER UNLEADED 87A GROSS LINE FAIL CLEAR 05-15-18 11:44 AMQ 1 OTHER UNLEADED 87A PLLD SHUTDOWN ALARM ALARM 05-15-18 11:27 AMQ 1 OTHER UNLEADED 87A GROSS LINE FAIL ALARM 05-15-18 11:27 AMQ 3 OTHER PREMIUM PLLD SHUTDOWN ALARM ALARM 05-15-18 11:07 AMQ 3 OTHER PREMIUM GROSS LINE FAIL ALARM 05-15-18 11:07 AMQ 4 OTHER DIESEL PLLD SHUTDOWN ALARM ALARM 05-15-18 10:47 AMQ 4 OTHER DIESEL GROSS LINE FAIL ALARM 05-15-18 10:47 AMQ 2 OTHER UNLEADED 87B PLLD SHUTDOWN ALARM ALARM 05-15-18 10:41 AMQ 2 OTHER UNLEADED 87B GROSS LINE FAIL ALARM 05-15-18 10:41 AMT 4 TANK Additive OVERFILL ALARM CLEAR 05-15-18 9:39 AMT 4 TANK Additive OVERFILL ALARM ALARM 05-15-18 9:37 AMT 4 TANK Additive PROBE OUT CLEAR 05-15-18 9:33 AMT 4 TANK Additive PROBE OUT ALARM 05-15-18 9:33 AML17 DISP PAN ADDITIVE VENT BOX FUEL ALARM CLEAR 05-15-18 9:31 AM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] L17 DISP PAN ADDITIVE VENT BOX FUEL ALARM ALARM 05-15-18 9:31 AML17 DISP PAN ADDITIVE VENT BOX SENSOR OUT ALARM CLEAR 05-15-18 9:30 AML17 DISP PAN ADDITIVE VENT BOX SENSOR OUT ALARM ALARM 05-15-18 9:30 AMT 1 TANK Unleaded PROBE OUT CLEAR 05-15-18 9:27 AMT 1 TANK Unleaded OVERFILL ALARM CLEAR 05-15-18 9:27 AMT 1 TANK Unleaded PROBE OUT ALARM 05-15-18 9:27 AMT 1 TANK Unleaded OVERFILL ALARM ALARM 05-15-18 9:26 AMT 1 TANK Unleaded PROBE OUT CLEAR 05-15-18 9:25 AMT 1 TANK Unleaded PROBE OUT ALARM 05-15-18 9:24 AMT 2 TANK Unleaded PROBE OUT CLEAR 05-15-18 9:23 AMT 2 TANK Unleaded OVERFILL ALARM CLEAR 05-15-18 9:22 AMT 2 TANK Unleaded PROBE OUT ALARM 05-15-18 9:22 AMT 2 TANK Unleaded OVERFILL ALARM ALARM 05-15-18 9:21 AMT 2 TANK Unleaded PROBE OUT CLEAR 05-15-18 9:21 AMT 2 TANK Unleaded PROBE OUT ALARM 05-15-18 9:20 AMT 3 TANK Premium PROBE OUT CLEAR 05-15-18 9:19 AMT 3 TANK Premium OVERFILL ALARM CLEAR 05-15-18 9:18 AMT 3 TANK Premium PROBE OUT ALARM 05-15-18 9:18 AMT 3 TANK Premium OVERFILL ALARM ALARM 05-15-18 9:18 AMT 3 TANK Premium PROBE OUT CLEAR 05-15-18 9:17 AMT 3 TANK Premium PROBE OUT ALARM 05-15-18 9:16 AMT 5 TANK Diesel OVERFILL ALARM CLEAR 05-15-18 9:14 AMT 5 TANK Diesel OVERFILL ALARM ALARM 05-15-18 9:12 AMT 5 TANK Diesel PROBE OUT CLEAR 05-15-18 9:10 AMT 5 TANK Diesel PROBE OUT ALARM 05-15-18 9:10 AMQ 4 OTHER DIESEL PLLD SHUTDOWN ALARM CLEAR 05-15-18 9:09 AMs 4 OTHER DIESEL VENT VAC. NO VACUUM ALARM CLEAR 05-15-18 9:09 AMs 4 OTHER DIESEL VENT VAC. NO VACUUM ALARM ALARM 05-15-18 9:08 AMQ 4 OTHER DIESEL PLLD SHUTDOWN ALARM ALARM 05-15-18 9:08 AM ============================Request: 118 - I11200 - Non-Priority Alarm historyRequest Source: Alarm History Request - Line: 4 _________________________ I11200 05-15-18 12:00 PM 207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA NON-PRIORITY ALARM HISTORYID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIMET 4 TANK Additive HIGH PRODUCT ALARM CLEAR 05-15-18 9:38 AMT 4 TANK Additive HIGH PRODUCT ALARM ALARM 05-15-18 9:38 AMT 4 TANK Additive LOW TEMP WARNING CLEAR 05-15-18 9:35 AMT 4 TANK Additive HIGH PRODUCT ALARM CLEAR 05-15-18 9:34 AMT 4 TANK Additive LOW TEMP WARNING ALARM 05-15-18 9:34 AMT 4 TANK Additive HIGH PRODUCT ALARM ALARM 05-15-18 9:34 AMT 1 TANK Unleaded LOW TEMP WARNING CLEAR 05-15-18 9:28 AMT 1 TANK Unleaded LOW TEMP WARNING ALARM 05-15-18 9:28 AMT 2 TANK Unleaded LOW TEMP WARNING CLEAR 05-15-18 9:24 AMT 2 TANK Unleaded LOW TEMP WARNING ALARM 05-15-18 9:24 AM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] T 5 TANK Diesel HIGH PRODUCT ALARM CLEAR 05-15-18 9:13 AMT 5 TANK Diesel HIGH PRODUCT ALARM ALARM 05-15-18 9:12 AML28 OTHER SETUP DATA WARNING CLEAR 05-15-18 9:03 AML27 OTHER SETUP DATA WARNING CLEAR 05-15-18 9:03 AML28 OTHER SETUP DATA WARNING ALARM 05-15-18 9:01 AML27 OTHER SETUP DATA WARNING ALARM 05-15-18 9:01 AML 9 STP SUMP PREMIUM STP LIQUID WARNING CLEAR 05-15-18 8:33 AML 9 STP SUMP PREMIUM STP LIQUID WARNING ALARM 05-15-18 8:33 AML 8 PIPE PREMIUM FILL LIQUID WARNING CLEAR 05-15-18 8:32 AML 8 PIPE PREMIUM FILL LIQUID WARNING ALARM 05-15-18 8:32 AML 5 PIPE UNLEADED 87B FILL LIQUID WARNING CLEAR 05-15-18 8:28 AML 5 PIPE UNLEADED 87B FILL LIQUID WARNING ALARM 05-15-18 8:28 AML 6 STP SUMP UNLEADED 87B STP LIQUID WARNING CLEAR 05-15-18 8:27 AML 6 STP SUMP UNLEADED 87B STP LIQUID WARNING ALARM 05-15-18 8:27 AML 2 PIPE UNLEADED 87A FILL LIQUID WARNING CLEAR 05-15-18 8:23 AML 2 PIPE UNLEADED 87A FILL LIQUID WARNING ALARM 05-15-18 8:23 AM SYSTEM PRINTER ERROR CLEAR 05-15-18 8:01 AM SYSTEM PAPER OUT CLEAR 05-15-18 8:01 AM SYSTEM PRINTER ERROR ALARM 05-15-18 8:01 AM SYSTEM PAPER OUT ALARM 05-15-18 8:01 AM SYSTEM PRINTER ERROR CLEAR 05-15-18 6:19 AM SYSTEM PAPER OUT CLEAR 05-15-18 6:19 AM SYSTEM PRINTER ERROR ALARM 05-15-18 6:19 AM SYSTEM PAPER OUT ALARM 05-15-18 6:19 AM OTHER ISD GROSS PRES WARN CLEAR 05-11-18 7:46 AM OTHER ISD GROSS PRES WARN ALARM 05-11-18 12:00 AMh16 OTHER FP16: BLEND2 DEGRD COLLECT WARN CLEAR 05-10-18 11:59 PM SYSTEM PRINTER ERROR CLEAR 05-08-18 4:19 PM SYSTEM PAPER OUT CLEAR 05-08-18 4:19 PM SYSTEM PRINTER ERROR ALARM 05-08-18 4:19 PM SYSTEM PAPER OUT ALARM 05-08-18 4:19 PM SYSTEM PRINTER ERROR CLEAR 05-08-18 4:19 PM SYSTEM PAPER OUT CLEAR 05-08-18 4:19 PM SYSTEM PAPER OUT ALARM 05-08-18 4:19 PM SYSTEM PRINTER ERROR ALARM 05-08-18 4:19 PMh16 OTHER FP16: BLEND2 DEGRD COLLECT WARN ALARM 05-08-18 12:00 AM OTHER ISD GROSS PRES WARN CLEAR 05-04-18 9:15 AMh16 OTHER FP16: BLEND2 DEGRD COLLECT WARN CLEAR 05-04-18 9:14 AMh 8 OTHER FP8: BLEND2 DEGRD COLLECT WARN CLEAR 05-02-18 11:59 PMh 8 OTHER FP8: BLEND2 DEGRD COLLECT WARN ALARM 05-02-18 12:00 AM ============================Request: 119 - I20600 - In-Tank Alarm historyRequest Source: Alarm History Request - Line: 5 _________________________ I20600 05-15-18 12:01 PM 207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] TANK ALARM HISTORY TANK 1 Unleaded LEAK ALARM 12-06-14 6:38 AM OVERFILL ALARM 05-15-18 9:26 AM 03-12-18 11:28 PM 11-07-17 7:33 PM LOW PRODUCT ALARM 08-13-15 7:52 PM 05-15-15 1:36 PM 12-04-14 11:54 AM SUDDEN LOSS ALARM 08-19-17 4:23 AM 02-06-17 10:52 AM 02-05-17 3:56 PM HIGH PRODUCT ALARM 06-10-15 9:29 AM 06-04-14 11:28 AM INVALID FUEL LEVEL 08-13-15 7:52 PM 05-15-15 1:36 PM 12-04-14 10:58 AM PROBE OUT 05-15-18 9:27 AM 05-15-18 9:24 AM 03-12-18 11:28 PM DELIVERY NEEDED 04-10-18 5:01 PM 04-04-18 2:36 PM 04-03-18 8:36 PM LOW TEMP WARNING 05-15-18 9:28 AM 05-18-16 7:53 AM TANK 2 Unleaded LEAK ALARM 12-06-14 6:38 AM OVERFILL ALARM 05-15-18 9:21 AM 03-12-18 11:33 PM 01-16-18 7:52 PM LOW PRODUCT ALARM 08-13-15 7:51 PM 05-15-15 1:34 PM SUDDEN LOSS ALARM 08-19-17 4:23 AM 12-04-14 8:49 AM INVALID FUEL LEVEL 08-13-15 7:51 PM 05-15-15 1:33 PM PROBE OUT 05-15-18 9:22 AM 05-15-18 9:20 AM 03-12-18 11:34 PM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] DELIVERY NEEDED 04-18-18 12:40 PM 04-10-18 4:55 PM 04-04-18 2:28 PM LOW TEMP WARNING 05-15-18 9:24 AM 03-12-18 11:35 PM 06-10-15 9:34 AM TANK 3 Premium SETUP DATA WARNING 01-20-14 11:20 AM LEAK ALARM 12-06-14 6:38 AM OVERFILL ALARM 05-15-18 9:18 AM 04-08-18 10:37 AM 03-12-18 11:39 PM LOW PRODUCT ALARM 03-12-18 11:41 PM 01-02-15 6:05 PM 12-05-14 1:19 PM INVALID FUEL LEVEL 03-12-18 11:41 PM 01-02-15 5:58 PM 12-05-14 1:09 PM PROBE OUT 05-15-18 9:18 AM 05-15-18 9:16 AM 03-12-18 11:40 PM DELIVERY NEEDED 04-25-18 10:49 AM 04-10-18 11:47 AM 03-12-18 11:41 PM LOW TEMP WARNING 06-10-15 9:40 AM TANK 4 Additive SETUP DATA WARNING 01-20-14 11:20 AM LEAK ALARM 12-06-14 6:38 AM OVERFILL ALARM 05-15-18 9:37 AM 05-11-18 8:45 AM 03-12-18 11:23 PM LOW PRODUCT ALARM 03-12-18 11:22 PM 07-25-17 4:18 AM 07-24-17 9:43 PM SUDDEN LOSS ALARM 03-26-15 5:53 AM HIGH PRODUCT ALARM 05-15-18 9:38 AM 05-15-18 9:34 AM 07-14-15 8:51 PM INVALID FUEL LEVEL 07-25-17 4:18 AM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] 07-24-17 9:43 PM 07-24-17 5:08 PM PROBE OUT 05-15-18 9:33 AM 07-25-17 5:23 AM 07-25-17 5:08 AM DELIVERY NEEDED 03-12-18 11:22 PM 07-25-17 4:18 AM 07-24-17 9:43 PM LOW TEMP WARNING 05-15-18 9:34 AM 07-25-17 5:26 AM 07-25-17 5:00 AM TANK 5 Diesel SETUP DATA WARNING 03-26-15 9:59 PM OVERFILL ALARM 05-15-18 9:12 AM 03-13-18 12:06 AM 05-17-17 8:52 AM LOW PRODUCT ALARM 12-03-15 8:48 AM 03-26-15 9:59 PM HIGH PRODUCT ALARM 05-15-18 9:12 AM 03-13-18 12:06 AM 05-17-17 8:51 AM PROBE OUT 05-15-18 9:10 AM 03-13-18 12:06 AM 03-13-18 12:03 AM DELIVERY NEEDED 04-16-18 3:56 PM 04-10-18 8:06 AM 03-15-18 11:07 AM MAX PRODUCT ALARM 03-26-15 6:30 AM LOW TEMP WARNING 03-13-18 12:07 AM 06-10-15 9:08 AM TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] TANK 16 ============================Request: 120 - I38200 - Pressure line Leak Alarm HistoryRequest Source: Alarm History Request - Line: 6 _________________________ I38200 05-15-18 12:01 PM 207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA PRESSURE LINE LEAK ALARM HISTORY REPORT Q 1:UNLEADED 87A 05-15-18 11:27 AM PLLD SHUTDOWN ALARM 05-15-18 11:27 AM GROSS LINE FAIL 05-15-18 9:01 AM PLLD SHUTDOWN ALARM 05-15-18 8:47 AM PLLD SHUTDOWN ALARM 05-15-18 8:46 AM PLLD SHUTDOWN ALARM 05-15-18 8:45 AM PLLD SHUTDOWN ALARM 05-15-18 8:44 AM PLLD SHUTDOWN ALARM 05-15-18 8:43 AM PLLD SHUTDOWN ALARM 05-15-18 8:42 AM PLLD SHUTDOWN ALARM 05-15-18 8:40 AM PLLD SHUTDOWN ALARM Q 2:UNLEADED 87B 05-15-18 10:41 AM PLLD SHUTDOWN ALARM 05-15-18 10:41 AM GROSS LINE FAIL 05-15-18 9:01 AM PLLD SHUTDOWN ALARM 05-15-18 8:47 AM PLLD SHUTDOWN ALARM 05-15-18 8:46 AM PLLD SHUTDOWN ALARM 05-15-18 8:45 AM PLLD SHUTDOWN ALARM 05-15-18 8:44 AM PLLD SHUTDOWN ALARM 05-15-18 8:43 AM PLLD SHUTDOWN ALARM 05-15-18 8:42 AM PLLD SHUTDOWN ALARM 05-15-18 8:40 AM PLLD SHUTDOWN ALARM Q 3:PREMIUM 05-15-18 11:07 AM PLLD SHUTDOWN ALARM 05-15-18 11:07 AM GROSS LINE FAIL 05-15-18 9:01 AM PLLD SHUTDOWN ALARM 05-15-18 8:47 AM PLLD SHUTDOWN ALARM 05-15-18 8:46 AM PLLD SHUTDOWN ALARM 05-15-18 8:45 AM PLLD SHUTDOWN ALARM 05-15-18 8:44 AM PLLD SHUTDOWN ALARM 05-15-18 8:43 AM PLLD SHUTDOWN ALARM 05-15-18 8:42 AM PLLD SHUTDOWN ALARM 05-15-18 8:40 AM PLLD SHUTDOWN ALARM Q 4:DIESEL file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] 05-15-18 10:47 AM PLLD SHUTDOWN ALARM 05-15-18 10:47 AM GROSS LINE FAIL 05-15-18 9:08 AM PLLD SHUTDOWN ALARM 05-15-18 9:06 AM PLLD SHUTDOWN ALARM 05-15-18 9:05 AM PLLD SHUTDOWN ALARM 05-15-18 9:03 AM PLLD SHUTDOWN ALARM 05-15-18 9:01 AM PLLD SHUTDOWN ALARM 05-15-18 8:59 AM PLLD SHUTDOWN ALARM 05-15-18 8:58 AM PLLD SHUTDOWN ALARM 05-15-18 8:58 AM PLLD SHUTDOWN ALARM ============================Request: 121 - I30200 - Liquid Sensor Alarm historyRequest Source: Alarm History Request - Line: 7 _________________________ I30200 05-15-18 12:01 PM 207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNLEADED 87A ANNULAR 05-15-18 9:02 AM SENSOR OUT ALARM 05-15-18 8:22 AM HIGH LIQUID ALARM 05-15-18 8:22 AM LOW LIQUID ALARM 2 UNLEADED 87A FILL 05-15-18 9:01 AM SENSOR OUT ALARM 05-15-18 8:23 AM LIQUID WARNING 03-12-18 10:29 PM LIQUID WARNING 3 UNLEADED 87A STP 05-15-18 9:01 AM SENSOR OUT ALARM 05-15-18 8:24 AM FUEL ALARM 03-12-18 10:31 PM FUEL ALARM 4 UNLEADED 87B ANNULAR 05-15-18 9:01 AM SENSOR OUT ALARM 05-15-18 8:29 AM HIGH LIQUID ALARM 05-15-18 8:29 AM LOW LIQUID ALARM 5 UNLEADED 87B FILL 05-15-18 9:02 AM SENSOR OUT ALARM 05-15-18 8:28 AM LIQUID WARNING 03-13-18 12:27 AM SETUP DATA WARNING 6 UNLEADED 87B STP 05-15-18 9:02 AM SENSOR OUT ALARM 05-15-18 8:27 AM LIQUID WARNING 03-21-18 9:26 PM LIQUID WARNING 7 PREMIUM ANNULAR 05-15-18 9:02 AM SENSOR OUT ALARM 05-15-18 8:31 AM HIGH LIQUID ALARM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] 05-15-18 8:30 AM LOW LIQUID ALARM 8 PREMIUM FILL 05-15-18 9:01 AM SENSOR OUT ALARM 05-15-18 8:32 AM LIQUID WARNING 03-13-18 12:49 AM SETUP DATA WARNING 9 PREMIUM STP 05-15-18 9:01 AM SENSOR OUT ALARM 05-15-18 8:33 AM LIQUID WARNING 03-13-18 12:27 AM SETUP DATA WARNING 10 DISPENSER PAN 1-2 05-15-18 9:01 AM SENSOR OUT ALARM 05-15-18 8:38 AM FUEL ALARM 03-12-18 10:46 PM FUEL ALARM 11 DISPENSER PAN 3-4 05-15-18 9:01 AM SENSOR OUT ALARM 05-15-18 8:37 AM FUEL ALARM 03-12-18 10:47 PM FUEL ALARM 12 DISPENSER PAN 5-6 05-15-18 9:01 AM SENSOR OUT ALARM 05-15-18 8:38 AM FUEL ALARM 03-12-18 10:48 PM FUEL ALARM 13 DISPENSER PAN 7-8 05-15-18 9:01 AM SENSOR OUT ALARM 05-15-18 8:39 AM FUEL ALARM 03-12-18 10:48 PM FUEL ALARM 14 DISPENSER PAN 9-10 05-15-18 9:01 AM SENSOR OUT ALARM 05-15-18 8:40 AM FUEL ALARM 03-12-18 10:49 PM FUEL ALARM 15 DISPENSER PAN 11-12 05-15-18 9:01 AM SENSOR OUT ALARM 05-15-18 8:40 AM FUEL ALARM 03-12-18 10:49 PM FUEL ALARM 16 ADDITIVE ANNULAR 05-15-18 9:01 AM SENSOR OUT ALARM 03-12-18 10:59 PM FUEL ALARM 03-12-18 9:44 PM SENSOR OUT ALARM 17 ADDITIVE VENT BOX 05-15-18 9:31 AM FUEL ALARM 05-15-18 9:30 AM SENSOR OUT ALARM 03-12-18 11:17 PM FUEL ALARM 21 DIESEL ANNULAR 05-15-18 9:02 AM SENSOR OUT ALARM 05-15-18 9:01 AM LOW LIQUID ALARM 05-15-18 8:53 AM HIGH LIQUID ALARM 22 DISPENSER PAN 13-14 05-15-18 8:44 AM FUEL ALARM 05-15-18 8:43 AM SENSOR OUT ALARM 05-15-18 8:42 AM LOW LIQUID ALARM 23 DISPENSER PAN 15-16 05-15-18 8:47 AM FUEL ALARM 05-15-18 8:46 AM SENSOR OUT ALARM 05-15-18 8:45 AM LOW LIQUID ALARM 24 DIESEL FILL 05-15-18 9:03 AM SENSOR OUT ALARM 05-15-18 9:02 AM SENSOR OUT ALARM 05-15-18 8:57 AM LOW LIQUID ALARM file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] 25 DIESEL STP 05-15-18 9:01 AM SENSOR OUT ALARM 05-15-18 8:59 AM SENSOR OUT ALARM 05-15-18 8:58 AM FUEL ALARM 26 DIESEL VENT 05-15-18 9:02 AM SENSOR OUT ALARM 05-15-18 8:49 AM FUEL ALARM 05-15-18 8:48 AM SENSOR OUT ALARM ============================Request: 122 - I31600 - Smart Sensor Alarm historyRequest Source: Alarm History Request - Line: 8 _________________________ I31600 05-15-18 12:01 PM 207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 VFM 13-14 03-12-18 9:43 PM COMMUNICATION ALARM 2 VFM 15,16 03-12-18 9:43 PM COMMUNICATION ALARM 3 DIESEL PRODUCT VAC. 05-15-18 9:06 AM NO VACUUM ALARM 05-15-18 9:05 AM HIGH LIQUID ALARM 03-13-18 12:10 AM NO VACUUM ALARM 4 DIESEL VENT VAC. 05-15-18 9:08 AM NO VACUUM ALARM 05-15-18 9:06 AM NO VACUUM ALARM 05-15-18 9:05 AM HIGH LIQUID ALARM 8 ATM P 9 VFM 1-2 03-12-18 9:43 PM COMMUNICATION ALARM 10 VFM 3-4 03-12-18 9:43 PM COMMUNICATION ALARM 11 VFM 5-6 03-12-18 9:43 PM COMMUNICATION ALARM 12 VFM 7-8 03-12-18 9:43 PM COMMUNICATION ALARM 02-09-18 12:04 PM COMMUNICATION ALARM 13 VFM 9-10 03-12-18 9:43 PM COMMUNICATION ALARM 01-13-15 7:31 AM COMMUNICATION ALARM 01-13-15 5:22 AM COMMUNICATION ALARM 14 VFM 11-12 03-12-18 9:43 PM COMMUNICATION ALARM 09-26-16 8:44 AM COMMUNICATION ALARM 16 PRESURE SENSOR 3-4 file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] 03-12-18 9:41 PM COMMUNICATION ALARM ============================Request: 123 - I40200 - Input Alarm HistoryRequest Source: Alarm History Request - Line: 9 _________________________ I40200 05-15-18 12:01 PM ============================Request: 124 - I40300 - Input-Generator Alarm HistoryRequest Source: Alarm History Request - Line: 10 _________________________ I40300 05-15-18 12:01 PM ============================Request: 125 - I34200 - Type A 2 Wire CL Alarm HistoryRequest Source: Alarm History Request - Line: 11 _________________________ I34200 05-15-18 12:01 PM ============================Request: 126 - I34700 - Type B 3 Wire CL Alarm HistoryRequest Source: Alarm History Request - Line: 12 _________________________ I34700 05-15-18 12:01 PM ============================Request: 127 - IV0100 - ISD Alarm Status Request Source: Alarm History Request - Line: 13 _________________________ IV0100 05-15-18 12:01 PM 207901 Costco 688 3800 Rosedale Highwa Bakersfield, CA file:///C/...a/Desktop/Monitoring%20Information/V-R%20Setup%20Printout/2018/%23688%20Bakersfield%20VR%20Alarm%20History.txt[5/16/2018 5:22:30 PM] ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSISTISD TYPE: 01.05VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMSDATE TIME DESCRIPTION READING VALUE18-05-11 00:00:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.5218-05-10 00:00:09 A/L RATIO DEGRADATION FP16 BLEND2 0.7718-05-09 00:00:09 A/L RATIO DEGRADATION FP16 BLEND2 0.7518-05-08 00:00:09 A/L RATIO DEGRADATION FP16 BLEND2 0.7318-05-04 00:00:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.4818-05-04 00:00:09 A/L RATIO DEGRADATION FP16 BLEND2 0.7918-05-03 00:00:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.4818-05-03 00:00:09 A/L RATIO DEGRADATION FP16 BLEND2 0.7918-05-02 00:00:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.2018-05-02 00:00:09 A/L RATIO DEGRADATION FP16 BLEND2 0.77 FAILURE ALARMSDATE TIME DESCRIPTION READING VALUE15-11-03 00:00:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.62 SHUTDOWN & MISCELLANEOUS EVENTSDATE TIME DESCRIPTION ACTION/NAME18-05-11 07:46:57 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 18-05-11 07:36:23 COLLECTION TEST HH16 GRADE TEST MANUALLY CLEARED 18-05-04 09:15:14 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 18-05-04 09:14:53 COLLECTION TEST HH16 GRADE TEST MANUALLY CLEARED 18-04-24 09:08:07 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 18-04-20 00:31:00 TIME CHANGE DETECTED AT: 18-04-20 00:28:5318-04-12 15:07:24 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 18-04-11 12:18:57 COLLECTION TEST HH15 GRADE TEST MANUALLY CLEARED 18-04-05 13:50:39 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 18-03-29 00:00:09 READINESS ISD:PP EVR:PP ISD & EVR READY End of Report: 180515 +============================================================================| Monitoring System Report Saved at: Tuesday, May 15, 2018 - 12:01:43 PM| (Report Saved Date/Time from PC Clock)| Using Monitoring System Report Utility || Version: Version 6.0.0.100 |+============================================================================