Loading...
HomeMy WebLinkAboutFMC 20182/21/07 1 MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of California Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. $General Information Facility Name: ________________________________________________________________________ Bldg. No.:___________________ Site Address: ________________________________________________ City: ________________________ Zip: ____________________ Facility Contact Person: ___________________________________________ Contact Phone No.: _________________________________ Make/Model of Monitoring System: ________________________________________ Date of Testing/Servicing: ___________________ %Inventory of Equipment Tested/CertifiedCheck the appropriate boxes to indicate specific equipment inspected/serviced: Tank ID: ____________________________________________ 2/21/072 D. Results of Testing/Servicing Software Version Installed: _____________________________________ Complete the following checklist: 2/21/073 F. In-Tank Gauging / SIR Equipment: Monitoring System Certification Form: Addendum for Vacuum/Pressure Interstitial Sensors I. Results of Vacuum/Pressure Monitoring Equipment Testing This page should be used to document testing and servicing of vacuum and pressure interstitial sensors. A copy of this form must be included with the Monitoring System Certification Form, which must be provided to the tank system owner/operator. The owner/operator must submit a copy of the Monitoring System Certification Form to the local agency regulating UST systems within 30 days of test date. Manufacturer: Veeder-Root Model: TLS-350 System Type: Pressure; Vacuum Sensor ID Component(s) Monitored by this Sensor: Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail Component(s) Monitored by this Sensor: Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail Component(s) Monitored by this Sensor: Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail Component(s) Monitored by this Sensor: Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail Component(s) Monitored by this Sensor: Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail Component(s) Monitored by this Sensor: Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail Component(s) Monitored by this Sensor: Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail Component(s) Monitored by this Sensor: Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail Component(s) Monitored by this Sensor: Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail Component(s) Monitored by this Sensor: Sensor Functionality Test Result: Pass; Fail Interstitial Communication Test Result: Pass; Fail How was interstitial communication verified? Leak Introduced at Far End of Interstitial Space;1 Gauge; Visual Inspection; Other (Describe in Sec. J, below) Was vacuum/pressure restored to operating levels in all interstitial spaces?Yes No (If no, describe in Sec. J, below) J. Comments: The leak was introduced at the three way ball valve. Page 4 of 4 1 If the sensor successfully detects a simulated vacuum/pressure leak introduced in the interstitial space at the furthest point from the sensor, vacuum/pressure has been demonstrated to be communicating throughout the interstice. UN-036A - 1/1 www.unidocs.org Rev. 01/26/06 S-1 Regular Product Line Regular Vent LineS-2 Regular VaporS-3 ■■ ■ ■ ■■ ■ ■ Leak Detector Test Results Sheet &ĂĐŝůŝƚLJEĂŵĞ͗Site Address: Test Date: TechnicianŽŶĚƵĐƚŝŶŐdĞƐƚ: ICC No.: Product Type LLD Type Model Serial No. Check Valve Holding Pressure Bleed Off ML. Leak Rate Tested: Pass/Fail 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi TechnicianSignature: Date: 87-1 Mech FX1V 10 psi 100 ml Pass 91 Mech FX1V 10 psi 70 ml Pass Dsl Mech FX1DV 12 psi 155 ml Pass 07/12/2018 Jaco #3367 Fastrip #640 07/12/2018 8001 White Lane Aaron Perrigo 8485827-UT Jaco 3367 Setup Responses Received: 200 FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 JUL 12, 2018 12:56 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 10044 93.61 0.0 86.1 1956 2 UNLEADED 2 10356 77.31 0.8 86.9 1644 3 PREMIUM 7052 54.63 0.0 91.1 4948 4 DIESEL 4016 44.23 0.0 86.9 7984 I90500 JUL 12, 2018 12:56 PM SOFTWARE REVISION LEVEL VERSION 329.00 SOFTWARE# 346329-100-A CREATED - 08.10.09.17.08 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I50500 JUL 12, 2018 12:56 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 JUL 12, 2018 12:56 PM SHIFT TIME 1 : 6:00 AM I50202 JUL 12, 2018 12:56 PM SHIFT TIME 2 : DISABLED I50203 JUL 12, 2018 12:56 PM SHIFT TIME 3 : DISABLED I50204 JUL 12, 2018 12:56 PM SHIFT TIME 4 : DISABLED I54600 JUL 12, 2018 12:56 PM TANK PER TST NEEDED WRN: DISABLED I54900 JUL 12, 2018 12:56 PM TANK ANN TST NEEDED WRN: DISABLED I55300 JUL 12, 2018 12:56 PM LINE RE-ENABLE METHOD PASS LINE TEST I55600 JUL 12, 2018 12:56 PM LINE PER TST NEEDED WRN: DISABLED I55900 JUL 12, 2018 12:56 PM LINE ANN TST NEEDED WRN: DISABLED I50D00 JUL 12, 2018 12:56 PM PRINT TC VOLUMES ENABLED I50E00 JUL 12, 2018 12:56 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 JUL 12, 2018 12:56 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 JUL 12, 2018 12:56 PM H-PROTOCOL DATA FORMAT HEIGHT I51A01 JUL 12, 2018 12:56 PM DAYLIGHT SAVING TIME ENABLED ON I51B00 JUL 12, 2018 12:56 PM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 JUL 12, 2018 12:56 PM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 JUL 12, 2018 12:56 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 JUL 12, 2018 12:56 PM TANK CHART SECURITY DISABLED I5BD00 JUL 12, 2018 12:56 PM CUSTOM ALARM LABELS DISABLED I56000 JUL 12, 2018 12:56 PM MASS/DENSITY DISABLED I88101 JUL 12, 2018 12:56 PM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 JUL 12, 2018 12:56 PM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 JUL 12, 2018 12:56 PM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88104 JUL 12, 2018 12:56 PM I88105 JUL 12, 2018 12:56 PM I88106 JUL 12, 2018 12:56 PM I52000 JUL 12, 2018 12:56 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE SEP 8, 2011 DISABLED 2 ON DATE SEP 8, 2011 DISABLED 3 ON DATE SEP 8, 2011 DISABLED 4 ON DATE SEP 8, 2011 DISABLED 5 ON DATE SEP 8, 2011 DISABLED 6 ON DATE SEP 8, 2011 DISABLED 7 ON DATE SEP 8, 2011 DISABLED 8 ON DATE SEP 8, 2011 DISABLED I60100 JUL 12, 2018 12:56 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 UNLEADED 2 ON 3 PREMIUM ON 4 DIESEL ON I60200 JUL 12, 2018 12:56 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 UNLEADED 2 3 PREMIUM 4 DIESEL I60300 JUL 12, 2018 12:56 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 UNLEADED 2 2 3 PREMIUM 3 4 DIESEL 4 I60900 JUL 12, 2018 12:56 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 UNLEADED 2 0.000700 3 PREMIUM 0.000700 4 DIESEL 0.000450 I60700 JUL 12, 2018 12:56 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 120.00 2 UNLEADED 2 96.00 3 PREMIUM 96.00 4 DIESEL 120.00 I60A00 JUL 12, 2018 12:56 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 1 PT 12000 2 UNLEADED 2 1 PT 12000 3 PREMIUM 1 PT 12000 4 DIESEL 1 PT 12000 I60400 JUL 12, 2018 12:56 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 12000 2 UNLEADED 2 12000 3 PREMIUM 12000 4 DIESEL 12000 I60500 JUL 12, 2018 12:56 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12000 0 0 0 2 UNLEADED 2 12000 0 0 0 3 PREMIUM 12000 0 0 0 4 DIESEL 12000 0 0 0 I60600 JUL 12, 2018 12:56 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 UNLEADED 2 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PREMIUM 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 DIESEL 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 JUL 12, 2018 12:56 PM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 UNLEADED 2 NO 3 PREMIUM NO 4 DIESEL NO I62F00 JUL 12, 2018 12:56 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 4.0 INCHES 2 UNLEADED 2 4.0 INCHES 3 PREMIUM 4.0 INCHES 4 DIESEL 4.0 INCHES I62700 JUL 12, 2018 12:56 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 UNLEADED 2 2.0 3 PREMIUM 2.0 4 DIESEL 2.0 9999FF1B I62400 JUL 12, 2018 12:56 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 UNLEADED 2 3.0 3 PREMIUM 3.0 4 DIESEL 3.0 I62800 JUL 12, 2018 12:56 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 12000 2 UNLEADED 2 12000 3 PREMIUM 12000 4 DIESEL 12000 I62300 JUL 12, 2018 12:56 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 10800 2 UNLEADED 2 10800 3 PREMIUM 10800 4 DIESEL 10800 I62200 JUL 12, 2018 12:56 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 11400 2 UNLEADED 2 11400 3 PREMIUM 11400 4 DIESEL 11400 I62900 JUL 12, 2018 12:56 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1200 2 UNLEADED 2 1200 3 PREMIUM 1200 4 DIESEL 1200 I62100 JUL 12, 2018 12:57 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1200 2 UNLEADED 2 1200 3 PREMIUM 1200 4 DIESEL 1200 I62600 JUL 12, 2018 12:57 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 UNLEADED 2 99 3 PREMIUM 99 4 DIESEL 99 I62500 JUL 12, 2018 12:57 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 UNLEADED 2 99 3 PREMIUM 99 4 DIESEL 99 I60800 JUL 12, 2018 12:57 PM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED -3.25 2 UNLEADED 2 -4.50 3 PREMIUM -11.50 4 DIESEL 0.00 I60B00 JUL 12, 2018 12:57 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 JUL 12, 2018 12:57 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 UNLEADED 2 0.00 3 PREMIUM 0.00 4 DIESEL 0.00 I61200 JUL 12, 2018 12:57 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED NONE NONE 2 UNLEADED 2 NONE NONE 3 PREMIUM NONE NONE 4 DIESEL NONE NONE I63600 JUL 12, 2018 12:57 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 UNLEADED 2 120 3 PREMIUM 120 4 DIESEL 120 I62A00 JUL 12, 2018 12:57 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 UNLEADED 2 120 3 PREMIUM 120 4 DIESEL 120 I62C00 JUL 12, 2018 12:57 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 UNLEADED 2 STANDARD 3 PREMIUM STANDARD 4 DIESEL STANDARD I62D00 JUL 12, 2018 12:57 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 UNLEADED 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 JUL 12, 2018 12:57 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 UNLEADED 2 OFF OFF 3 PREMIUM OFF OFF 4 DIESEL OFF OFF I63000 JUL 12, 2018 12:57 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 UNLEADED 2 OFF 3 PREMIUM OFF 4 DIESEL OFF I63200 JUL 12, 2018 12:57 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 UNLEADED 2 OFF 3 PREMIUM OFF 4 DIESEL OFF I61000 JUL 12, 2018 12:57 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 1 2 UNLEADED 2 1 3 PREMIUM 1 4 DIESEL 1 I63A00 JUL 12, 2018 12:57 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 UNLEADED 2 10.00% 3 PREMIUM 10.00% 4 DIESEL 10.00% I61100 JUL 12, 2018 12:57 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK OCT 9, 2008 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 JUL 12, 2018 12:57 PM CSLD PROBABLITY OF DETECTION I61400 JUL 12, 2018 12:57 PM CSLD CLIMATE FACTOR I61600 JUL 12, 2018 12:57 PM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 UNLEADED 2 IMMEDIATE 3 PREMIUM IMMEDIATE 4 DIESEL IMMEDIATE I61A00 JUL 12, 2018 12:57 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED DISABLED 2 UNLEADED 2 DISABLED 3 PREMIUM DISABLED 4 DIESEL DISABLED I61B00 JUL 12, 2018 12:57 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 JUL 12, 2018 12:57 PM CSLD REPORT ONLY I62B00 JUL 12, 2018 12:57 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED ??? 0, 0 2 UNLEADED 2 ??? 0, 0 3 PREMIUM ??? 0, 0 4 DIESEL ??? 0, 0 I63300 JUL 12, 2018 12:57 PM LEAK TEST REPORT FORMAT: NORMAL I63400 JUL 12, 2018 12:57 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 UNLEADED 2 0 3 PREMIUM 0 4 DIESEL 0 I63500 JUL 12, 2018 12:57 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 UNLEADED 2 1 3 PREMIUM 1 4 DIESEL 1 I63900 JUL 12, 2018 12:57 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED END FACTOR: NONE 2 UNLEADED 2 END FACTOR: NONE 3 PREMIUM END FACTOR: NONE 4 DIESEL END FACTOR: NONE I78000 JUL 12, 2018 12:57 PM I77700 JUL 12, 2018 12:57 PM I77800 JUL 12, 2018 12:57 PM I78C00 JUL 12, 2018 12:57 PM I78300 JUL 12, 2018 12:57 PM I78F00 JUL 12, 2018 12:57 PM I78700 JUL 12, 2018 12:57 PM I70200 JUL 12, 2018 12:57 PM LIQUID LABEL DEVICE LABEL 1 UNL ANN 2 UNL STP 3 UNL FILL 4 UNL 2 STP 5 UNL 2 STP 6 UNL 2 STP ANN 7 UNL 2 FILL 8 UNL 2 ANN FILL 9 UNL 2 ANN 10 PREM ANN 11 PREM STP 12 PREM FILL 13 DSL ANN 14 DSL STP 15 DSL FILL 16 DISP 13-14 17 DISP 15-16 18 DISP 17-18 19 DISP 19-20 20 DISP 21-22 21 DISP 23-24 22 VENTBOX 23 24 I70300 JUL 12, 2018 12:57 PM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL ANN TRI-STATE (SINGLE FLOAT) 2 UNL STP TRI-STATE (SINGLE FLOAT) 3 UNL FILL TRI-STATE (SINGLE FLOAT) 4 UNL 2 STP TRI-STATE (SINGLE FLOAT) 5 UNL 2 STP TRI-STATE (SINGLE FLOAT) 6 UNL 2 STP ANN NORMALLY CLOSED 7 UNL 2 FILL NORMALLY CLOSED 8 UNL 2 ANN FILL NORMALLY CLOSED 9 UNL 2 ANN DUAL POINT HYDROSTATIC 10 PREM ANN TRI-STATE (SINGLE FLOAT) 11 PREM STP TRI-STATE (SINGLE FLOAT) 12 PREM FILL TRI-STATE (SINGLE FLOAT) 13 DSL ANN TRI-STATE (SINGLE FLOAT) 14 DSL STP TRI-STATE (SINGLE FLOAT) 15 DSL FILL TRI-STATE (SINGLE FLOAT) 16 DISP 13-14 TRI-STATE (SINGLE FLOAT) 17 DISP 15-16 TRI-STATE (SINGLE FLOAT) 18 DISP 17-18 TRI-STATE (SINGLE FLOAT) 19 DISP 19-20 TRI-STATE (SINGLE FLOAT) 20 DISP 21-22 TRI-STATE (SINGLE FLOAT) 21 DISP 23-24 TRI-STATE (SINGLE FLOAT) 22 VENTBOX TRI-STATE (SINGLE FLOAT) 23 TRI-STATE (SINGLE FLOAT) 24 TRI-STATE (SINGLE FLOAT) I70400 JUL 12, 2018 12:57 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL ANN ANNULAR SPACE 2 UNL STP STP SUMP 3 UNL FILL PIPING SUMP 4 UNL 2 STP STP SUMP 5 UNL 2 STP STP SUMP 6 UNL 2 STP ANN ANNULAR SPACE 7 UNL 2 FILL PIPING SUMP 8 UNL 2 ANN FILL ANNULAR SPACE 9 UNL 2 ANN ANNULAR SPACE 10 PREM ANN ANNULAR SPACE 11 PREM STP STP SUMP 12 PREM FILL PIPING SUMP 13 DSL ANN ANNULAR SPACE 14 DSL STP STP SUMP 15 DSL FILL OTHER SENSORS 16 DISP 13-14 DISPENSER PAN 17 DISP 15-16 DISPENSER PAN 18 DISP 17-18 DISPENSER PAN 19 DISP 19-20 DISPENSER PAN 20 DISP 21-22 DISPENSER PAN 21 DISP 23-24 DISPENSER PAN 22 VENTBOX PIPING SUMP 23 OTHER SENSORS 24 OTHER SENSORS I74200 JUL 12, 2018 12:57 PM I74300 JUL 12, 2018 12:57 PM I74400 JUL 12, 2018 12:57 PM I74700 JUL 12, 2018 12:57 PM I74800 JUL 12, 2018 12:57 PM I74900 JUL 12, 2018 12:57 PM I7BC00 JUL 12, 2018 12:57 PM I80200 JUL 12, 2018 12:57 PM I80300 JUL 12, 2018 12:57 PM I80400 JUL 12, 2018 12:57 PM I80700 JUL 12, 2018 12:57 PM RELAY LABEL DEVICE LABEL 1 POS SHUT OFF 2 3 UNLD 1 4 OVERFILL ALARM 5 INTERNAL ALARM 6 7 8 ANNUNCIATOR I80900 JUL 12, 2018 12:57 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 POS SHUT OFF NORMALLY CLOSED 2 NORMALLY OPEN 3 UNLD 1 NORMALLY OPEN 4 OVERFILL ALARM NORMALLY OPEN 5 INTERNAL ALARM NORMALLY OPEN 6 NORMALLY OPEN 7 NORMALLY OPEN 8 ANNUNCIATOR NORMALLY CLOSED I80B00 JUL 12, 2018 12:57 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 POS SHUT OFF 1 2 NONE 3 UNLD 1 1 4 OVERFILL ALARM NONE 5 INTERNAL ALARM NONE 6 NONE 7 NONE 8 ANNUNCIATOR NONE I80A00 JUL 12, 2018 12:57 PM RELAY TYPE RELAY DESIGNATION TYPE 1 POS SHUT OFF STANDARD 2 STANDARD 3 UNLD 1 PUMP CONTROL OUTPUT 4 OVERFILL ALARM STANDARD 5 INTERNAL ALARM MOMENTARY 6 STANDARD 7 STANDARD 8 ANNUNCIATOR STANDARD I80C00 JUL 12, 2018 12:57 PM I80800 JUL 12, 2018 12:57 PM RELAY SETUP REPORT R 1:POS SHUT OFF TYPE: STANDARD NORMALLY CLOSED TANK #: 1 LIQUID SENSOR ALMS L 2:FUEL ALARM L 5:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L14:FUEL ALARM L16:FUEL ALARM L17:FUEL ALARM L18:FUEL ALARM L19:FUEL ALARM L20:FUEL ALARM L21:FUEL ALARM L 2:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L11:SENSOR OUT ALARM L14:SENSOR OUT ALARM L16:SENSOR OUT ALARM L17:SENSOR OUT ALARM L18:SENSOR OUT ALARM L19:SENSOR OUT ALARM L20:SENSOR OUT ALARM L21:SENSOR OUT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 5:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L16:SHORT ALARM L17:SHORT ALARM L18:SHORT ALARM L19:SHORT ALARM L20:SHORT ALARM L21:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 3:UNLD 1 TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 2:FUEL ALARM L 5:FUEL ALARM L11:FUEL ALARM L14:FUEL ALARM L16:FUEL ALARM L17:FUEL ALARM L18:FUEL ALARM L19:FUEL ALARM L20:FUEL ALARM L21:FUEL ALARM L 2:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L11:SENSOR OUT ALARM L16:SENSOR OUT ALARM L17:SENSOR OUT ALARM L18:SENSOR OUT ALARM L19:SENSOR OUT ALARM L20:SENSOR OUT ALARM L21:SENSOR OUT ALARM L 2:SHORT ALARM L 5:SHORT ALARM L11:SHORT ALARM L16:SHORT ALARM L17:SHORT ALARM L18:SHORT ALARM L19:SHORT ALARM L20:SHORT ALARM L21:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 5:INTERNAL ALARM TYPE: MOMENTARY NORMALLY OPEN LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM SMARTSENSOR ALARMS ALL:NO VACUUM ALARM R 6: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 7: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 8:ANNUNCIATOR TYPE: STANDARD NORMALLY CLOSED TANK #: NONE IN-TANK ALARMS ALL:LEAK ALARM ALL:HIGH WATER ALARM ALL:OVERFILL ALARM ALL:LOW PRODUCT ALARM ALL:SUDDEN LOSS ALARM ALL:HIGH PRODUCT ALARM ALL:INVALID FUEL LEVEL ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED ALL:MAX PRODUCT ALARM ALL:GROSS TEST FAIL ALL:PERIODIC TEST FAIL ALL:ANNUAL TEST FAIL ALL:PER TST NEEDED WRN ALL:ANN TST NEEDED WRN ALL:PER TST NEEDED ALM ALL:ANN TST NEEDED ALM ALL:TANK TEST ACTIVE ALL:NO CSLD IDLE TIME ALL:TANK SIPHON BREAK ALL:CSLD INCR RATE WARN ALL:ACCU_CHART CAL WARN ALL:RECON WARNING ALL:RECON ALARM ALL:LOW TEMP WARNING ALL:MISSING TICKET WARN ALL:GROSS FAIL LINE TNK ALL:DELIVY DENSITY WARN LIQUID SENSOR ALMS ALL:FUEL ALARM ALL:SENSOR OUT ALARM ALL:SHORT ALARM ISD SITE ALARMS ISD STAGE I WARN ISD GROSS PRES WARN ISD GROSS PRES FAIL ISD DEGRD PRES WARN ISD DEGRD PRES FAIL ISD VAPOR LEAK WARN ISD VAPOR LEAK FAIL ISD VP PRES WARN ISD VP PRES FAIL ISD VP STATUS WARN ISD VP STATUS FAIL MISSING RELAY SETUP MISSING HOSE SETUP MISSING TANK SETUP MISS VAPOR FLOW MTR MISS VAPOR PRES SEN MISSING VP INPUT ISD SETUP WARN ISD SETUP FAIL ISD SENSOR OUT WARN ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT WARN ALL:DEGRD COLLECT WARN ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT WARN ALL:FLOW COLLECT FAIL ALL:AIRFLOW MTR SETUP I79000 JUL 12, 2018 12:58 PM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 JUL 12, 2018 12:58 PM I72300 JUL 12, 2018 12:58 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 UNL 2 LINE VAC SENSOR 02 UNL 2 VENT VAC SENSOR 03 VAPOR VAC SENSOR 04 UNKNOWN 05 UNKNOWN 06 UNKNOWN 07 UNKNOWN 08 ATM ATM P SENSOR 09 PS 17-18 VAPOR PRESSURE 10 FM 13-14 AIR FLOW METER 11 FM 15-16 AIR FLOW METER 12 FM 17-18 AIR FLOW METER 13 FM 19-20 AIR FLOW METER 14 FM 21-22 AIR FLOW METER 15 FM 23-24 AIR FLOW METER 16 PS 17-18 VAPOR PRESSURE 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 JUL 12, 2018 12:58 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 JUL 12, 2018 12:58 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 JUL 12, 2018 12:58 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 VAPOR PROCESSOR TYPE NONE IV4700 JUL 12, 2018 12:58 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 JUL 12, 2018 12:58 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 ACCEPT HIGH ORVR: NO IV4A00 JUL 12, 2018 12:58 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 01 13 01 BLEND3 02 02 14 01 BLEND3 03 03 15 02 BLEND3 04 04 16 02 BLEND3 05 05 17 03 BLEND3 06 06 18 03 BLEND3 07 07 19 04 BLEND3 08 08 20 04 BLEND3 09 09 21 05 BLEND3 10 10 22 05 BLEND3 11 11 23 06 BLEND3 12 12 24 06 BLEND3 IV4B00 JUL 12, 2018 12:58 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 03/01 09/01 02/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx 09 05 02/09 03/09 09/09 xx/xx 10 05 02/10 03/10 09/10 xx/xx 11 06 02/11 03/11 09/11 xx/xx 12 06 02/12 03/12 09/12 xx/xx IV4900 JUL 12, 2018 12:58 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 JUL 12, 2018 12:58 PM ISD VERSION: 01.02 Jaco 3367 Alarm History Responses Received: I10200 JUL 12, 2018 12:59 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 508508 507145 2 8SMARTSENSOR BD 39557 39556 3 4 PROBE / G.T. 164218 164286 4 INTERSTITIAL BD 201866 201896 5 INTERSTITIAL BD 202194 202205 6 INTERSTITIAL BD 202779 202537 7 UNUSED 4921727 4921983 8 UNUSED 4919569 4922596 9 RELAY BOARD 14935 14956 10 STP SENSE BOARD 33394 33420 11 RELAY BOARD 15130 15132 12 UNUSED 4923785 4925217 13 UNUSED 4922252 4924297 14 UNUSED 4921281 4925019 15 UNUSED 4921238 4920859 16 UNUSED 4920245 4921713 COMM 1 ELEC DISP INT. 101406 101394 COMM 2 RS232 SERIAL BD 15021 15022 COMM 3 RS232 SERIAL BD 14978 14978 COMM 4 UNUSED 4924799 4926727 COMM 5 UNUSED 4922382 4923465 COMM 6 UNUSED 4921756 4922939 I90200 JUL 12, 2018 12:59 PM SOFTWARE REVISION LEVEL VERSION 329.00 SOFTWARE# 346329-100-A CREATED - 08.10.09.17.08 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 JUL 12, 2018 12:59 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK UNLEADED 2 OVERFILL ALARM CLEAR 7-11-18 2:51PM T 2 TANK UNLEADED 2 OVERFILL ALARM ALARM 7-11-18 2:49PM T 1 TANK UNLEADED SUDDEN LOSS ALARM CLEAR 7-11-18 3:25AM T 1 TANK UNLEADED SUDDEN LOSS ALARM ALARM 7-11-18 2:41AM T 3 TANK PREMIUM OVERFILL ALARM CLEAR 7-08-18 5:02PM T 3 TANK PREMIUM OVERFILL ALARM ALARM 7-08-18 4:55PM L 8 ANNULAR UNL 2 ANN FILL FUEL ALARM CLEAR 7-05-18 6:46PM L 8 ANNULAR UNL 2 ANN FILL FUEL ALARM ALARM 7-05-18 6:43PM L 6 ANNULAR UNL 2 STP ANN FUEL ALARM CLEAR 7-05-18 6:38PM L 6 ANNULAR UNL 2 STP ANN FUEL ALARM ALARM 7-05-18 6:38PM L21 DISP PAN DISP 23-24 FUEL ALARM CLEAR 7-05-18 6:32PM L21 DISP PAN DISP 23-24 FUEL ALARM ALARM 7-05-18 6:32PM L12 PIPE PREM FILL SENSOR OUT ALARM CLEAR 7-05-18 5:57PM L11 STP SUMP PREM STP SENSOR OUT ALARM CLEAR 7-05-18 5:57PM L 9 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 7-05-18 5:57PM L20 DISP PAN DISP 21-22 SENSOR OUT ALARM CLEAR 7-05-18 5:57PM L16 DISP PAN DISP 13-14 SENSOR OUT ALARM CLEAR 7-05-18 5:57PM L 8 ANNULAR UNL 2 ANN FILL FUEL ALARM CLEAR 7-05-18 5:57PM L15 OTHER DSL FILL SENSOR OUT ALARM CLEAR 7-05-18 5:57PM L 7 PIPE UNL 2 FILL FUEL ALARM CLEAR 7-05-18 5:57PM L22 PIPE VENTBOX SENSOR OUT ALARM CLEAR 7-05-18 5:57PM L 3 PIPE UNL FILL SENSOR OUT ALARM CLEAR 7-05-18 5:57PM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 7-05-18 5:57PM L21 DISP PAN DISP 23-24 SENSOR OUT ALARM CLEAR 7-05-18 5:57PM L 6 ANNULAR UNL 2 STP ANN FUEL ALARM CLEAR 7-05-18 5:57PM L19 DISP PAN DISP 19-20 SENSOR OUT ALARM CLEAR 7-05-18 5:57PM L14 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 7-05-18 5:57PM L18 DISP PAN DISP 17-18 SENSOR OUT ALARM CLEAR 7-05-18 5:57PM L13 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 7-05-18 5:57PM L 5 STP SUMP UNL 2 STP SENSOR OUT ALARM CLEAR 7-05-18 5:57PM L10 ANNULAR PREM ANN SENSOR OUT ALARM CLEAR 7-05-18 5:57PM L17 DISP PAN DISP 15-16 SENSOR OUT ALARM CLEAR 7-05-18 5:57PM L12 PIPE PREM FILL SENSOR OUT ALARM ALARM 7-05-18 5:57PM L16 DISP PAN DISP 13-14 SENSOR OUT ALARM ALARM 7-05-18 5:57PM L 8 ANNULAR UNL 2 ANN FILL FUEL ALARM ALARM 7-05-18 5:57PM L 7 PIPE UNL 2 FILL FUEL ALARM ALARM 7-05-18 5:57PM L22 PIPE VENTBOX SENSOR OUT ALARM ALARM 7-05-18 5:57PM L15 OTHER DSL FILL SENSOR OUT ALARM ALARM 7-05-18 5:57PM L10 ANNULAR PREM ANN SENSOR OUT ALARM ALARM 7-05-18 5:57PM L 9 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 7-05-18 5:57PM L 6 ANNULAR UNL 2 STP ANN FUEL ALARM ALARM 7-05-18 5:57PM L14 STP SUMP DSL STP SENSOR OUT ALARM ALARM 7-05-18 5:57PM L 3 PIPE UNL FILL SENSOR OUT ALARM ALARM 7-05-18 5:57PM L13 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 7-05-18 5:57PM L 5 STP SUMP UNL 2 STP SENSOR OUT ALARM ALARM 7-05-18 5:57PM L21 DISP PAN DISP 23-24 SENSOR OUT ALARM ALARM 7-05-18 5:57PM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 7-05-18 5:57PM L20 DISP PAN DISP 21-22 SENSOR OUT ALARM ALARM 7-05-18 5:57PM L19 DISP PAN DISP 19-20 SENSOR OUT ALARM ALARM 7-05-18 5:57PM L11 STP SUMP PREM STP SENSOR OUT ALARM ALARM 7-05-18 5:57PM I11200 JUL 12, 2018 12:59 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 3 TANK PREMIUM HIGH PRODUCT ALARM CLEAR 7-08-18 11:35PM T 3 TANK PREMIUM HIGH PRODUCT ALARM ALARM 7-08-18 4:58PM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM CLEAR 7-05-18 2:18PM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM ALARM 7-05-18 2:17PM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM CLEAR 6-29-18 2:22PM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM ALARM 6-29-18 2:20PM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM CLEAR 6-29-18 2:19PM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM ALARM 6-29-18 2:16PM SYSTEM PRINTER ERROR CLEAR 6-18-18 12:08PM SYSTEM PAPER OUT CLEAR 6-18-18 12:08PM SYSTEM PRINTER ERROR ALARM 6-18-18 12:08PM SYSTEM PAPER OUT ALARM 6-18-18 12:08PM h 5 OTHER FP17: BLEND3 GROSS COLLECT WARN CLEAR 6-15-18 10:00AM h 5 OTHER FP17: BLEND3 GROSS COLLECT WARN ALARM 6-14-18 10:01AM h11 OTHER FP23: BLEND3 GROSS COLLECT WARN CLEAR 5-26-18 10:00AM h11 OTHER FP23: BLEND3 GROSS COLLECT WARN ALARM 5-25-18 10:01AM SYSTEM PRINTER ERROR CLEAR 5-11-18 4:34AM SYSTEM PAPER OUT CLEAR 5-11-18 4:34AM SYSTEM PRINTER ERROR ALARM 5-11-18 4:34AM SYSTEM PAPER OUT ALARM 5-11-18 4:34AM SYSTEM PRINTER ERROR CLEAR 5-11-18 4:34AM SYSTEM PRINTER ERROR ALARM 5-11-18 4:33AM SYSTEM PRINTER ERROR CLEAR 5-11-18 4:33AM SYSTEM PAPER OUT CLEAR 5-11-18 4:33AM SYSTEM PRINTER ERROR ALARM 5-11-18 4:33AM SYSTEM PAPER OUT ALARM 5-11-18 4:33AM SYSTEM PRINTER ERROR CLEAR 5-11-18 1:50AM SYSTEM PAPER OUT CLEAR 5-11-18 1:50AM SYSTEM PRINTER ERROR ALARM 5-11-18 1:50AM SYSTEM PAPER OUT ALARM 5-11-18 1:50AM SYSTEM PRINTER ERROR CLEAR 5-11-18 1:50AM SYSTEM PRINTER ERROR ALARM 5-11-18 1:50AM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM CLEAR 5-06-18 11:22AM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM ALARM 5-06-18 11:15AM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM CLEAR 5-06-18 10:57AM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM ALARM 5-06-18 10:47AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 5-02-18 1:08PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 5-02-18 11:53AM OTHER ISD SENSOR OUT WARN CLEAR 4-24-18 8:45AM OTHER ISD SENSOR OUT WARN ALARM 4-22-18 10:01AM SYSTEM PRINTER ERROR CLEAR 4-02-18 2:39AM SYSTEM PAPER OUT CLEAR 4-02-18 2:39AM SYSTEM PRINTER ERROR ALARM 4-02-18 2:39AM SYSTEM PAPER OUT ALARM 4-02-18 2:39AM SYSTEM PRINTER ERROR CLEAR 4-02-18 2:39AM SYSTEM PAPER OUT CLEAR 4-02-18 2:39AM SYSTEM PRINTER ERROR ALARM 4-02-18 2:39AM SYSTEM PAPER OUT ALARM 4-02-18 2:39AM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM CLEAR 3-18-18 11:39AM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM ALARM 3-18-18 11:09AM I20600 JUL 12, 2018 12:59 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 TANK ALARM HISTORY TANK 1 UNLEADED HIGH WATER ALARM JUL 8, 2016 1:11 PM OVERFILL ALARM MAR 20, 2018 4:44 PM MAR 18, 2018 11:29 AM MAR 18, 2018 11:22 AM LOW PRODUCT ALARM OCT 6, 2017 3:51 AM AUG 9, 2017 5:22 AM FEB 24, 2017 9:07 PM SUDDEN LOSS ALARM JUL 11, 2018 2:41 AM JUN 7, 2018 2:42 AM JUN 7, 2018 2:21 AM HIGH PRODUCT ALARM AUG 9, 2017 5:20 AM JUL 14, 2016 12:17 PM JUL 8, 2016 1:06 PM INVALID FUEL LEVEL OCT 6, 2017 3:51 AM AUG 9, 2017 5:23 AM OCT 5, 2016 3:51 AM PROBE OUT OCT 9, 2017 1:54 PM AUG 10, 2017 9:26 AM AUG 10, 2017 9:22 AM HIGH WATER WARNING JUL 8, 2016 1:11 PM JUL 7, 2014 4:26 PM DELIVERY NEEDED OCT 6, 2017 3:51 AM AUG 9, 2017 5:22 AM FEB 24, 2017 9:07 PM LOW TEMP WARNING JUL 10, 2017 10:55 AM MAR 7, 2017 5:33 PM MAR 7, 2017 4:47 PM TANK 2 UNLEADED 2 SETUP DATA WARNING JUL 16, 2012 10:30 AM OVERFILL ALARM JUL 11, 2018 2:49 PM JUL 5, 2018 2:17 PM JUN 29, 2018 2:20 PM LOW PRODUCT ALARM JUN 15, 2017 3:10 PM MAY 9, 2017 3:32 PM MAY 8, 2017 5:57 PM SUDDEN LOSS ALARM JUL 8, 2016 11:13 AM JUL 7, 2015 4:23 PM JUL 7, 2015 3:54 PM HIGH PRODUCT ALARM JUL 5, 2018 2:17 PM JUN 29, 2018 2:20 PM JUN 29, 2018 2:16 PM INVALID FUEL LEVEL JUN 10, 2016 6:13 PM JUN 4, 2016 4:13 AM MAY 21, 2016 6:25 PM PROBE OUT JUL 12, 2017 12:38 PM JUL 12, 2017 12:33 PM JUL 10, 2017 10:55 AM DELIVERY NEEDED JUN 15, 2017 3:09 PM MAY 9, 2017 3:31 PM MAY 8, 2017 5:57 PM MAX PRODUCT ALARM JUL 14, 2016 12:20 PM JUL 16, 2012 10:30 AM LOW TEMP WARNING JUL 12, 2017 12:40 PM JUL 10, 2017 10:56 AM MAR 6, 2017 8:52 PM TANK 3 PREMIUM OVERFILL ALARM JUL 8, 2018 4:55 PM JUN 14, 2018 9:22 PM MAY 23, 2018 3:54 AM LOW PRODUCT ALARM FEB 21, 2016 7:25 PM JAN 10, 2016 3:45 PM DEC 9, 2015 1:11 PM HIGH PRODUCT ALARM JUL 8, 2018 4:58 PM JUL 19, 2017 6:18 AM JUL 12, 2017 12:15 PM INVALID FUEL LEVEL JUL 21, 2015 1:25 PM DEC 18, 2013 9:46 AM PROBE OUT JUL 12, 2017 12:16 PM JUL 12, 2017 12:06 PM JUL 10, 2017 10:53 AM DELIVERY NEEDED FEB 21, 2016 7:24 PM JAN 10, 2016 3:45 PM DEC 9, 2015 1:11 PM MAX PRODUCT ALARM JUL 12, 2017 12:15 PM JUL 14, 2016 12:21 PM JUL 21, 2015 1:26 PM LOW TEMP WARNING JUL 8, 2013 10:13 AM JUL 8, 2013 9:37 AM TANK 4 DIESEL OVERFILL ALARM JUL 10, 2017 10:51 AM JUL 8, 2016 11:22 AM JUL 7, 2015 3:38 PM LOW PRODUCT ALARM MAY 2, 2018 11:53 AM JUL 12, 2017 12:07 PM MAY 6, 2016 10:26 AM HIGH PRODUCT ALARM JUL 12, 2017 12:14 PM JUL 14, 2016 12:22 PM JUL 8, 2016 11:23 AM PROBE OUT JUL 12, 2017 12:14 PM JUL 12, 2017 12:07 PM JUL 10, 2017 10:52 AM DELIVERY NEEDED MAY 2, 2018 11:53 AM JUL 12, 2017 12:07 PM MAY 6, 2016 10:26 AM MAX PRODUCT ALARM JUL 14, 2016 12:22 PM LOW TEMP WARNING JUL 12, 2017 12:15 PM JUL 21, 2015 1:14 PM JUL 7, 2015 3:39 PM I38200 JUL 12, 2018 12:59 PM I30200 JUL 12, 2018 12:59 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL ANN JUL 5, 2018 5:57 PM SENSOR OUT ALARM JUL 5, 2018 5:48 PM FUEL ALARM OCT 11, 2017 3:55 PM FUEL ALARM 2 UNL STP JUL 5, 2018 5:23 PM FUEL ALARM JUL 5, 2018 5:22 PM FUEL ALARM APR 30, 2018 1:20 PM FUEL ALARM 3 UNL FILL JUL 5, 2018 5:57 PM SENSOR OUT ALARM JUL 5, 2018 5:43 PM FUEL ALARM MAR 21, 2018 2:16 PM FUEL ALARM 5 UNL 2 STP JUL 5, 2018 5:57 PM SENSOR OUT ALARM JUL 5, 2018 5:20 PM FUEL ALARM JUL 12, 2017 2:03 PM SENSOR OUT ALARM 6 UNL 2 STP ANN JUL 5, 2018 6:38 PM FUEL ALARM JUL 5, 2018 5:57 PM FUEL ALARM NOV 17, 2017 9:36 AM FUEL ALARM 7 UNL 2 FILL JUL 5, 2018 5:57 PM FUEL ALARM SEP 3, 2017 9:10 PM FUEL ALARM SEP 3, 2017 5:57 PM FUEL ALARM 8 UNL 2 ANN FILL JUL 5, 2018 6:43 PM FUEL ALARM JUL 5, 2018 5:57 PM FUEL ALARM JUN 28, 2018 2:33 AM SENSOR OUT ALARM 9 UNL 2 ANN JUL 5, 2018 5:57 PM SENSOR OUT ALARM JUL 5, 2018 5:46 PM HIGH LIQUID ALARM JUL 5, 2018 5:46 PM LOW LIQUID ALARM 10 PREM ANN JUL 5, 2018 5:57 PM SENSOR OUT ALARM JUL 5, 2018 5:49 PM FUEL ALARM JUL 25, 2017 1:07 PM SENSOR OUT ALARM 11 PREM STP JUL 5, 2018 5:57 PM SENSOR OUT ALARM JUL 5, 2018 5:25 PM FUEL ALARM JUL 5, 2018 5:25 PM FUEL ALARM 12 PREM FILL JUL 5, 2018 5:57 PM SENSOR OUT ALARM JUL 5, 2018 5:40 PM FUEL ALARM JUL 5, 2018 5:39 PM FUEL ALARM 13 DSL ANN JUL 5, 2018 5:57 PM SENSOR OUT ALARM JUL 5, 2018 5:52 PM FUEL ALARM JUL 5, 2018 5:52 PM FUEL ALARM 14 DSL STP JUL 5, 2018 5:57 PM SENSOR OUT ALARM JUL 5, 2018 5:27 PM FUEL ALARM JUL 12, 2017 2:03 PM SENSOR OUT ALARM 15 DSL FILL JUL 5, 2018 5:57 PM SENSOR OUT ALARM JUL 25, 2017 12:34 AM FUEL ALARM JUL 12, 2017 2:03 PM SENSOR OUT ALARM 16 DISP 13-14 JUL 5, 2018 5:57 PM SENSOR OUT ALARM JUL 5, 2018 5:11 PM FUEL ALARM JUL 12, 2017 2:03 PM SENSOR OUT ALARM 17 DISP 15-16 JUL 5, 2018 5:57 PM SENSOR OUT ALARM JUL 5, 2018 5:08 PM FUEL ALARM JUL 12, 2017 2:03 PM SENSOR OUT ALARM 18 DISP 17-18 JUL 5, 2018 5:57 PM SENSOR OUT ALARM JUL 5, 2018 5:08 PM FUEL ALARM JUL 12, 2017 1:55 PM FUEL ALARM 19 DISP 19-20 JUL 5, 2018 5:57 PM SENSOR OUT ALARM JUL 5, 2018 5:13 PM FUEL ALARM JUL 12, 2017 2:03 PM SENSOR OUT ALARM 20 DISP 21-22 JUL 5, 2018 5:57 PM SENSOR OUT ALARM JUL 5, 2018 5:15 PM FUEL ALARM JUL 12, 2017 2:03 PM SENSOR OUT ALARM 21 DISP 23-24 JUL 5, 2018 6:32 PM FUEL ALARM JUL 5, 2018 5:57 PM SENSOR OUT ALARM JUL 5, 2018 5:16 PM FUEL ALARM 22 VENTBOX JUL 5, 2018 5:57 PM SENSOR OUT ALARM JUL 12, 2017 2:03 PM SENSOR OUT ALARM JUL 10, 2017 11:08 AM FUEL ALARM I31600 JUL 12, 2018 12:59 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 2 LINE JUL 12, 2017 1:51 PM HIGH LIQUID ALARM JUL 12, 2017 1:49 PM SENSOR FAULT ALARM JUL 12, 2017 1:42 PM NO VACUUM ALARM 2 UNL 2 VENT AUG 14, 2017 4:00 PM NO VACUUM ALARM JUL 12, 2017 1:30 PM NO VACUUM ALARM JUL 12, 2017 1:30 PM HIGH LIQUID ALARM 3 VAPOR JUL 12, 2017 1:31 PM NO VACUUM ALARM JUL 12, 2017 1:30 PM HIGH LIQUID ALARM JUL 12, 2017 1:16 PM HIGH LIQUID ALARM 8 ATM 10 FM 13-14 11 FM 15-16 12 FM 17-18 13 FM 19-20 14 FM 21-22 15 FM 23-24 JUL 7, 2014 4:31 PM COMMUNICATION ALARM 16 PS 17-18 MAR 14, 2018 12:49 PM COMMUNICATION ALARM I40200 JUL 12, 2018 12:59 PM I40300 JUL 12, 2018 12:59 PM I34200 JUL 12, 2018 12:59 PM I34700 JUL 12, 2018 12:59 PM IV0100 JUL 12, 2018 12:59 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.02 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% STAGE I TRANSFERS: 0 of 0 NOTEST EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 18-06-14 10:01:49 A/L RATIO GROSS BLOCKAGE FP17 BLEND3 BLKD 18-05-25 10:01:23 A/L RATIO GROSS BLOCKAGE FP23 BLEND3 BLKD 18-04-23 10:01:51 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 4:FM 19-20 18-04-22 10:01:53 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 4:FM 19-20 18-03-03 10:02:09 A/L RATIO DEGRADATION FP18 BLEND3 0.00 18-03-03 10:02:09 A/L RATIO GROSS BLOCKAGE FP18 BLEND3 BLKD 18-02-02 10:01:27 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.27 18-01-26 10:02:07 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.45 18-01-13 10:01:39 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.23 18-01-06 10:01:27 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.49 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 18-01-06 10:01:27 A/L RATIO GROSS BLOCKAGE FP18 BLEND3 BLKD 15-07-26 10:02:20 A/L RATIO GROSS BLOCKAGE FP19 BLEND3 BLKD 14-06-23 10:01:34 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.56 10-10-25 10:01:47 A/L RATIO GROSS BLOCKAGE FP22 BLEND3 BLKD 10-10-25 10:01:47 A/L RATIO GROSS BLOCKAGE FP21 BLEND3 BLKD 09-08-20 10:01:50 A/L RATIO GROSS BLOCKAGE FP20 BLEND3 BLKD 09-08-20 10:01:50 A/L RATIO GROSS BLOCKAGE FP19 BLEND3 BLKD 09-08-19 10:01:59 A/L RATIO GROSS BLOCKAGE FP20 BLEND3 BLKD 09-08-19 10:01:59 A/L RATIO GROSS BLOCKAGE FP19 BLEND3 BLKD 09-08-18 10:01:35 A/L RATIO GROSS BLOCKAGE FP20 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 18-04-24 08:45:12 SENSOR OUT TEST MANUALLY CLEARED 18-04-24 08:45:00 COLLECTION TEST HH08 GRADE TEST MANUALLY CLEARED 18-04-24 08:44:53 COLLECTION TEST HH07 GRADE TEST MANUALLY CLEARED 18-03-11 03:00:00 TIME CHANGE DETECTED AT: 18-03-11 02:00:13 18-03-04 08:17:07 COLLECTION TEST HH06 GRADE TEST MANUALLY CLEARED 18-03-04 08:16:19 COLLECTION TEST HH07 GRADE TEST MANUALLY CLEARED 18-02-02 12:52:54 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 18-01-26 10:39:01 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 18-01-13 10:23:17 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 18-01-06 10:48:35 COLLECTION TEST HH06 GRADE TEST MANUALLY CLEARED Jaco 3367 Alarm History After Responses Received: I10200 JUL 12, 2018 3:36 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 508508 506991 2 8SMARTSENSOR BD 39557 39534 3 4 PROBE / G.T. 164218 163993 4 INTERSTITIAL BD 201866 201747 5 INTERSTITIAL BD 202194 201937 6 INTERSTITIAL BD 202779 202507 7 UNUSED 4921727 4908615 8 UNUSED 4919569 4906360 9 RELAY BOARD 14935 14911 10 STP SENSE BOARD 33394 33354 11 RELAY BOARD 15130 15110 12 UNUSED 4923785 4911739 13 UNUSED 4922252 4910885 14 UNUSED 4921281 4908608 15 UNUSED 4921238 4912440 16 UNUSED 4920245 4912659 COMM 1 ELEC DISP INT. 101406 101466 COMM 2 RS232 SERIAL BD 15021 15022 COMM 3 RS232 SERIAL BD 14978 14955 COMM 4 UNUSED 4924799 4916622 COMM 5 UNUSED 4922382 4915549 COMM 6 UNUSED 4921756 4915834 I90200 JUL 12, 2018 3:36 PM SOFTWARE REVISION LEVEL VERSION 329.00 SOFTWARE# 346329-100-A CREATED - 08.10.09.17.08 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 JUL 12, 2018 3:36 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 8 ANNULAR UNL 2 ANN FILL FUEL ALARM CLEAR 7-12-18 3:35PM L 7 PIPE UNL 2 FILL FUEL ALARM CLEAR 7-12-18 3:35PM L 6 ANNULAR UNL 2 STP ANN FUEL ALARM CLEAR 7-12-18 3:35PM L 3 PIPE UNL FILL SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L 2 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L12 PIPE PREM FILL SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L11 STP SUMP PREM STP SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L10 ANNULAR PREM ANN SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L 5 STP SUMP UNL 2 STP SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L15 OTHER DSL FILL SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L14 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L 1 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L 9 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L16 DISP PAN DISP 13-14 SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L13 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L22 PIPE VENTBOX SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L20 DISP PAN DISP 21-22 SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L19 DISP PAN DISP 19-20 SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L18 DISP PAN DISP 17-18 SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L21 DISP PAN DISP 23-24 SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L17 DISP PAN DISP 15-16 SENSOR OUT ALARM CLEAR 7-12-18 3:35PM L22 PIPE VENTBOX SENSOR OUT ALARM ALARM 7-12-18 3:34PM L20 DISP PAN DISP 21-22 SENSOR OUT ALARM ALARM 7-12-18 3:34PM L19 DISP PAN DISP 19-20 SENSOR OUT ALARM ALARM 7-12-18 3:34PM L18 DISP PAN DISP 17-18 SENSOR OUT ALARM ALARM 7-12-18 3:34PM L14 STP SUMP DSL STP SENSOR OUT ALARM ALARM 7-12-18 3:34PM L16 DISP PAN DISP 13-14 SENSOR OUT ALARM ALARM 7-12-18 3:34PM L15 OTHER DSL FILL SENSOR OUT ALARM ALARM 7-12-18 3:34PM L12 PIPE PREM FILL SENSOR OUT ALARM ALARM 7-12-18 3:34PM L11 STP SUMP PREM STP SENSOR OUT ALARM ALARM 7-12-18 3:34PM L10 ANNULAR PREM ANN SENSOR OUT ALARM ALARM 7-12-18 3:34PM L17 DISP PAN DISP 15-16 SENSOR OUT ALARM ALARM 7-12-18 3:34PM L21 DISP PAN DISP 23-24 SENSOR OUT ALARM ALARM 7-12-18 3:34PM L13 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 7-12-18 3:34PM L 8 ANNULAR UNL 2 ANN FILL FUEL ALARM ALARM 7-12-18 3:34PM L 7 PIPE UNL 2 FILL FUEL ALARM ALARM 7-12-18 3:34PM L 6 ANNULAR UNL 2 STP ANN FUEL ALARM ALARM 7-12-18 3:34PM L 3 PIPE UNL FILL SENSOR OUT ALARM ALARM 7-12-18 3:34PM L 2 STP SUMP UNL STP SENSOR OUT ALARM ALARM 7-12-18 3:34PM L 9 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 7-12-18 3:34PM L 5 STP SUMP UNL 2 STP SENSOR OUT ALARM ALARM 7-12-18 3:34PM L 1 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 7-12-18 3:34PM T 2 TANK UNLEADED 2 PROBE OUT CLEAR 7-12-18 3:30PM T 2 TANK UNLEADED 2 OVERFILL ALARM CLEAR 7-12-18 3:27PM T 2 TANK UNLEADED 2 PROBE OUT ALARM 7-12-18 3:27PM T 2 TANK UNLEADED 2 OVERFILL ALARM ALARM 7-12-18 3:27PM T 1 TANK UNLEADED PROBE OUT CLEAR 7-12-18 3:26PM T 1 TANK UNLEADED OVERFILL ALARM CLEAR 7-12-18 3:26PM T 1 TANK UNLEADED PROBE OUT ALARM 7-12-18 3:25PM T 1 TANK UNLEADED OVERFILL ALARM ALARM 7-12-18 3:25PM I11200 JUL 12, 2018 3:36 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK UNLEADED LOW TEMP WARNING CLEAR 7-12-18 3:29PM T 1 TANK UNLEADED LOW TEMP WARNING ALARM 7-12-18 3:26PM T 4 TANK DIESEL LOW TEMP WARNING CLEAR 7-12-18 3:25PM T 4 TANK DIESEL LOW TEMP WARNING ALARM 7-12-18 3:23PM T 3 TANK PREMIUM LOW TEMP WARNING CLEAR 7-12-18 3:22PM T 3 TANK PREMIUM LOW TEMP WARNING ALARM 7-12-18 3:20PM T 3 TANK PREMIUM HIGH PRODUCT ALARM CLEAR 7-12-18 3:19PM T 3 TANK PREMIUM HIGH PRODUCT ALARM ALARM 7-12-18 3:19PM T 3 TANK PREMIUM HIGH PRODUCT ALARM CLEAR 7-08-18 11:35PM T 3 TANK PREMIUM HIGH PRODUCT ALARM ALARM 7-08-18 4:58PM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM CLEAR 7-05-18 2:18PM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM ALARM 7-05-18 2:17PM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM CLEAR 6-29-18 2:22PM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM ALARM 6-29-18 2:20PM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM CLEAR 6-29-18 2:19PM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM ALARM 6-29-18 2:16PM SYSTEM PRINTER ERROR CLEAR 6-18-18 12:08PM SYSTEM PAPER OUT CLEAR 6-18-18 12:08PM SYSTEM PRINTER ERROR ALARM 6-18-18 12:08PM SYSTEM PAPER OUT ALARM 6-18-18 12:08PM h 5 OTHER FP17: BLEND3 GROSS COLLECT WARN CLEAR 6-15-18 10:00AM h 5 OTHER FP17: BLEND3 GROSS COLLECT WARN ALARM 6-14-18 10:01AM h11 OTHER FP23: BLEND3 GROSS COLLECT WARN CLEAR 5-26-18 10:00AM h11 OTHER FP23: BLEND3 GROSS COLLECT WARN ALARM 5-25-18 10:01AM SYSTEM PRINTER ERROR CLEAR 5-11-18 4:34AM SYSTEM PAPER OUT CLEAR 5-11-18 4:34AM SYSTEM PRINTER ERROR ALARM 5-11-18 4:34AM SYSTEM PAPER OUT ALARM 5-11-18 4:34AM SYSTEM PRINTER ERROR CLEAR 5-11-18 4:34AM SYSTEM PRINTER ERROR ALARM 5-11-18 4:33AM SYSTEM PRINTER ERROR CLEAR 5-11-18 4:33AM SYSTEM PAPER OUT CLEAR 5-11-18 4:33AM SYSTEM PRINTER ERROR ALARM 5-11-18 4:33AM SYSTEM PAPER OUT ALARM 5-11-18 4:33AM SYSTEM PRINTER ERROR CLEAR 5-11-18 1:50AM SYSTEM PAPER OUT CLEAR 5-11-18 1:50AM SYSTEM PRINTER ERROR ALARM 5-11-18 1:50AM SYSTEM PAPER OUT ALARM 5-11-18 1:50AM SYSTEM PRINTER ERROR CLEAR 5-11-18 1:50AM SYSTEM PRINTER ERROR ALARM 5-11-18 1:50AM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM CLEAR 5-06-18 11:22AM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM ALARM 5-06-18 11:15AM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM CLEAR 5-06-18 10:57AM T 2 TANK UNLEADED 2 HIGH PRODUCT ALARM ALARM 5-06-18 10:47AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 5-02-18 1:08PM T 4 TANK DIESEL DELIVERY NEEDED ALARM 5-02-18 11:53AM OTHER ISD SENSOR OUT WARN CLEAR 4-24-18 8:45AM OTHER ISD SENSOR OUT WARN ALARM 4-22-18 10:01AM SYSTEM PRINTER ERROR CLEAR 4-02-18 2:39AM SYSTEM PAPER OUT CLEAR 4-02-18 2:39AM I20600 JUL 12, 2018 3:36 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 TANK ALARM HISTORY TANK 1 UNLEADED HIGH WATER ALARM JUL 8, 2016 1:11 PM OVERFILL ALARM JUL 12, 2018 3:25 PM MAR 20, 2018 4:44 PM MAR 18, 2018 11:29 AM LOW PRODUCT ALARM OCT 6, 2017 3:51 AM AUG 9, 2017 5:22 AM FEB 24, 2017 9:07 PM SUDDEN LOSS ALARM JUL 12, 2018 1:50 PM JUL 11, 2018 2:41 AM JUN 7, 2018 2:42 AM HIGH PRODUCT ALARM AUG 9, 2017 5:20 AM JUL 14, 2016 12:17 PM JUL 8, 2016 1:06 PM INVALID FUEL LEVEL OCT 6, 2017 3:51 AM AUG 9, 2017 5:23 AM OCT 5, 2016 3:51 AM PROBE OUT JUL 12, 2018 3:25 PM JUL 12, 2018 1:50 PM OCT 9, 2017 1:54 PM HIGH WATER WARNING JUL 8, 2016 1:11 PM JUL 7, 2014 4:26 PM DELIVERY NEEDED OCT 6, 2017 3:51 AM AUG 9, 2017 5:22 AM FEB 24, 2017 9:07 PM LOW TEMP WARNING JUL 12, 2018 3:26 PM JUL 10, 2017 10:55 AM MAR 7, 2017 5:33 PM TANK 2 UNLEADED 2 SETUP DATA WARNING JUL 16, 2012 10:30 AM OVERFILL ALARM JUL 12, 2018 3:27 PM JUL 11, 2018 2:49 PM JUL 5, 2018 2:17 PM LOW PRODUCT ALARM JUN 15, 2017 3:10 PM MAY 9, 2017 3:32 PM MAY 8, 2017 5:57 PM SUDDEN LOSS ALARM JUL 8, 2016 11:13 AM JUL 7, 2015 4:23 PM JUL 7, 2015 3:54 PM HIGH PRODUCT ALARM JUL 5, 2018 2:17 PM JUN 29, 2018 2:20 PM JUN 29, 2018 2:16 PM INVALID FUEL LEVEL JUN 10, 2016 6:13 PM JUN 4, 2016 4:13 AM MAY 21, 2016 6:25 PM PROBE OUT JUL 12, 2018 3:27 PM JUL 12, 2018 1:42 PM JUL 12, 2017 12:38 PM DELIVERY NEEDED JUN 15, 2017 3:09 PM MAY 9, 2017 3:31 PM MAY 8, 2017 5:57 PM MAX PRODUCT ALARM JUL 14, 2016 12:20 PM JUL 16, 2012 10:30 AM LOW TEMP WARNING JUL 12, 2017 12:40 PM JUL 10, 2017 10:56 AM MAR 6, 2017 8:52 PM TANK 3 PREMIUM OVERFILL ALARM JUL 12, 2018 3:19 PM JUL 8, 2018 4:55 PM JUN 14, 2018 9:22 PM LOW PRODUCT ALARM FEB 21, 2016 7:25 PM JAN 10, 2016 3:45 PM DEC 9, 2015 1:11 PM HIGH PRODUCT ALARM JUL 12, 2018 3:19 PM JUL 8, 2018 4:58 PM JUL 19, 2017 6:18 AM INVALID FUEL LEVEL JUL 21, 2015 1:25 PM DEC 18, 2013 9:46 AM PROBE OUT JUL 12, 2018 3:19 PM JUL 12, 2018 1:38 PM JUL 12, 2017 12:16 PM DELIVERY NEEDED FEB 21, 2016 7:24 PM JAN 10, 2016 3:45 PM DEC 9, 2015 1:11 PM MAX PRODUCT ALARM JUL 12, 2017 12:15 PM JUL 14, 2016 12:21 PM JUL 21, 2015 1:26 PM LOW TEMP WARNING JUL 12, 2018 3:20 PM JUL 8, 2013 10:13 AM JUL 8, 2013 9:37 AM TANK 4 DIESEL OVERFILL ALARM JUL 12, 2018 3:22 PM JUL 10, 2017 10:51 AM JUL 8, 2016 11:22 AM LOW PRODUCT ALARM MAY 2, 2018 11:53 AM JUL 12, 2017 12:07 PM MAY 6, 2016 10:26 AM HIGH PRODUCT ALARM JUL 12, 2017 12:14 PM JUL 14, 2016 12:22 PM JUL 8, 2016 11:23 AM PROBE OUT JUL 12, 2018 3:23 PM JUL 12, 2018 1:39 PM JUL 12, 2017 12:14 PM DELIVERY NEEDED MAY 2, 2018 11:53 AM JUL 12, 2017 12:07 PM MAY 6, 2016 10:26 AM MAX PRODUCT ALARM JUL 14, 2016 12:22 PM LOW TEMP WARNING JUL 12, 2018 3:23 PM JUL 12, 2017 12:15 PM JUL 21, 2015 1:14 PM I38200 JUL 12, 2018 3:36 PM I30200 JUL 12, 2018 3:36 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL ANN JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:56 PM FUEL ALARM JUL 5, 2018 5:57 PM SENSOR OUT ALARM 2 UNL STP JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:19 PM FUEL ALARM JUL 12, 2018 2:12 PM FUEL ALARM 3 UNL FILL JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:22 PM FUEL ALARM JUL 5, 2018 5:57 PM SENSOR OUT ALARM 5 UNL 2 STP JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:20 PM FUEL ALARM JUL 5, 2018 5:57 PM SENSOR OUT ALARM 6 UNL 2 STP ANN JUL 12, 2018 3:34 PM FUEL ALARM JUL 12, 2018 2:21 PM FUEL ALARM JUL 5, 2018 6:38 PM FUEL ALARM 7 UNL 2 FILL JUL 12, 2018 3:34 PM FUEL ALARM JUL 12, 2018 2:22 PM FUEL ALARM JUL 5, 2018 5:57 PM FUEL ALARM 8 UNL 2 ANN FILL JUL 12, 2018 3:34 PM FUEL ALARM JUL 12, 2018 2:21 PM FUEL ALARM JUL 5, 2018 6:43 PM FUEL ALARM 9 UNL 2 ANN JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:59 PM LOW LIQUID ALARM JUL 12, 2018 2:58 PM HIGH LIQUID ALARM 10 PREM ANN JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:56 PM FUEL ALARM JUL 5, 2018 5:57 PM SENSOR OUT ALARM 11 PREM STP JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:08 PM FUEL ALARM JUL 5, 2018 5:57 PM SENSOR OUT ALARM 12 PREM FILL JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:23 PM FUEL ALARM JUL 5, 2018 5:57 PM SENSOR OUT ALARM 13 DSL ANN JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:56 PM FUEL ALARM JUL 5, 2018 5:57 PM SENSOR OUT ALARM 14 DSL STP JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:08 PM FUEL ALARM JUL 5, 2018 5:57 PM SENSOR OUT ALARM 15 DSL FILL JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:23 PM FUEL ALARM JUL 5, 2018 5:57 PM SENSOR OUT ALARM 16 DISP 13-14 JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:55 PM FUEL ALARM JUL 5, 2018 5:57 PM SENSOR OUT ALARM 17 DISP 15-16 JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:53 PM FUEL ALARM JUL 5, 2018 5:57 PM SENSOR OUT ALARM 18 DISP 17-18 JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:25 PM FUEL ALARM JUL 5, 2018 5:57 PM SENSOR OUT ALARM 19 DISP 19-20 JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:54 PM FUEL ALARM JUL 5, 2018 5:57 PM SENSOR OUT ALARM 20 DISP 21-22 JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:27 PM FUEL ALARM JUL 5, 2018 5:57 PM SENSOR OUT ALARM 21 DISP 23-24 JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:26 PM FUEL ALARM JUL 5, 2018 6:32 PM FUEL ALARM 22 VENTBOX JUL 12, 2018 3:34 PM SENSOR OUT ALARM JUL 12, 2018 2:59 PM FUEL ALARM JUL 5, 2018 5:57 PM SENSOR OUT ALARM I31600 JUL 12, 2018 3:36 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 2 LINE JUL 12, 2018 3:18 PM HIGH LIQUID ALARM JUL 12, 2018 3:16 PM NO VACUUM ALARM JUL 12, 2017 1:51 PM HIGH LIQUID ALARM 2 UNL 2 VENT JUL 12, 2018 3:18 PM HIGH LIQUID ALARM JUL 12, 2018 3:17 PM NO VACUUM ALARM AUG 14, 2017 4:00 PM NO VACUUM ALARM 3 VAPOR JUL 12, 2018 3:18 PM HIGH LIQUID ALARM JUL 12, 2018 3:18 PM NO VACUUM ALARM JUL 12, 2017 1:31 PM NO VACUUM ALARM 8 ATM 10 FM 13-14 11 FM 15-16 12 FM 17-18 13 FM 19-20 14 FM 21-22 15 FM 23-24 JUL 7, 2014 4:31 PM COMMUNICATION ALARM 16 PS 17-18 MAR 14, 2018 12:49 PM COMMUNICATION ALARM I40200 JUL 12, 2018 3:36 PM I40300 JUL 12, 2018 3:36 PM I34200 JUL 12, 2018 3:36 PM I34700 JUL 12, 2018 3:36 PM IV0100 JUL 12, 2018 3:36 PM FASTRIP 367 8001 WHITE LANE BAKERSFIELD CA,93309 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.02 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% STAGE I TRANSFERS: 0 of 0 NOTEST EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 18-06-14 10:01:49 A/L RATIO GROSS BLOCKAGE FP17 BLEND3 BLKD 18-05-25 10:01:23 A/L RATIO GROSS BLOCKAGE FP23 BLEND3 BLKD 18-04-23 10:01:51 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 4:FM 19-20 18-04-22 10:01:53 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 4:FM 19-20 18-03-03 10:02:09 A/L RATIO DEGRADATION FP18 BLEND3 0.00 18-03-03 10:02:09 A/L RATIO GROSS BLOCKAGE FP18 BLEND3 BLKD 18-02-02 10:01:27 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.27 18-01-26 10:02:07 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.45 18-01-13 10:01:39 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.23 18-01-06 10:01:27 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.49 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 18-01-06 10:01:27 A/L RATIO GROSS BLOCKAGE FP18 BLEND3 BLKD 15-07-26 10:02:20 A/L RATIO GROSS BLOCKAGE FP19 BLEND3 BLKD 14-06-23 10:01:34 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.56 10-10-25 10:01:47 A/L RATIO GROSS BLOCKAGE FP22 BLEND3 BLKD 10-10-25 10:01:47 A/L RATIO GROSS BLOCKAGE FP21 BLEND3 BLKD 09-08-20 10:01:50 A/L RATIO GROSS BLOCKAGE FP20 BLEND3 BLKD 09-08-20 10:01:50 A/L RATIO GROSS BLOCKAGE FP19 BLEND3 BLKD 09-08-19 10:01:59 A/L RATIO GROSS BLOCKAGE FP20 BLEND3 BLKD 09-08-19 10:01:59 A/L RATIO GROSS BLOCKAGE FP19 BLEND3 BLKD 09-08-18 10:01:35 A/L RATIO GROSS BLOCKAGE FP20 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 18-07-12 15:34:06 READINESS ISD:PP EVR:NN EVR READINESS PENDING 18-07-12 15:34:06 ISD STARTUP 18-07-12 15:33:54 ISD SHUTDOWN 18-04-24 08:45:12 SENSOR OUT TEST MANUALLY CLEARED 18-04-24 08:45:00 COLLECTION TEST HH08 GRADE TEST MANUALLY CLEARED 18-04-24 08:44:53 COLLECTION TEST HH07 GRADE TEST MANUALLY CLEARED 18-03-11 03:00:00 TIME CHANGE DETECTED AT: 18-03-11 02:00:13 18-03-04 08:17:07 COLLECTION TEST HH06 GRADE TEST MANUALLY CLEARED 18-03-04 08:16:19 COLLECTION TEST HH07 GRADE TEST MANUALLY CLEARED 18-02-02 12:52:54 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: Date of Testing: Facility Address: Facility Contact: Phone: Date Local Agency Was Notified of Testing : Name of Local Agency Inspector (if present during testing): 2. TESTING CONTRACTOR INFORMATION Company Name: Technician Conducting Test: Credentials1: CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) __________________ License Number(s): 3. SPILL BUCKET TESTING INFORMATION Test Method Used: Hydrostatic Vacuum Other Test Equipment Used: Equipment Resolution: Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1234 Bucket Installation Type: Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test: Test Start Time (TI): Initial Reading (RI): Test End Time (TF): Final Reading (RF): Test Duration (TF –TI): Change in Reading (RF -RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Comments –(include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician’s Signature:________________________________________________ Date:_________________________ 1 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. Jaco #3367 Fastrip #640 07/12/2018 8001 White Lane Omero Garcia 661-393-7000 6-8-2018 Kris Karns Confidence UST Services, Inc. Aaron Perrigo 804904 Lake Test 0.0625” 11.00” 11.00”11.00”11.00” 13.00” 13.00” 13.00” 13.00” 5 min 5 min 5 min 5 min 2:00pm 2:00pm 2:00pm 2:00pm 8.75” 9.75” 10.25” 10.00” 3:00pm 3:00pm 3:00pm 3:00pm 8.75” 9.75” 10.25” 10.00” 1 hr 1 hr 1 hr 1 hr 0.00” 0.00” 0.00” 0.00” 0.0625” 0.0625” 0.0625” 0.0625” 07/12/2018 ✔✔ ✔ ✔✔✔✔ ✔✔✔✔ 87-1 87-2 Prem Dsl 8485827-UT